GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

Embed Size (px)

Citation preview

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    1/65

    ZXSDR BTS Structure and Principle

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    2/65

    Agenda

    ZXSDR BTS Fam ily Introduc t ion

    ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    3/65

    Evolution of Multi-Mode BTS

    ZTE macro-BTS, IP

    architecture, 18TRX cabinet

    Traditional macro-BTS, ATM

    architecture, 12TRX cabinet

    Different BTS systems

    overlapped

    TDM/ATM platform

    Narrowband architecture

    Low integration and high

    consumption

    G1 Multimode

    BTS

    Different BTS SystemsInterchanged

    3G BBU/RRU Interchangeable

    IP/ATM architecture

    Increasing integration

    G2 Multimode

    BTS

    Shared broadband multi-carrier module

    Shared uTCA BBU

    Full-IP architecture and unified platform

    Multi-system conversion for same frequency

    softwareUltra-high integration and low consumption

    G3 Multimode

    BTS - SDR

    Unified Radio Resource

    Management

    System conversion for

    adjacent frequency software

    Integrated BSC function

    MESH network Architecture

    G4 Multimode

    BTS - Flat SDR

    ZTE SDR, 36TRX cabinet

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    4/65

    ZTE SDR Base Station Platform

    Multiple mode, multiple frequency

    band, unified hardware platform

    Base band processing unit based

    onTCA structure

    SDR helps you to achieve:

    Optimizedfrequency resource utilization Optimized networkresource

    Smooth innovation of wirelessnetwork Best networking solution forTCO

    Separate baseband and radio

    Radio unit based on MCPA

    CDMA2000

    GSM TD-SCDMA

    WiMAX

    WCDMA

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    5/65

    ATCA/mTCA

    ATCA (Advanced Telecommunication Computer Architecture):

    adopted by PICMG in 2003

    Micro TCA (u TCA): ATCA, be fit for accessing network

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    6/65

    Broadband MCPA

    Single-Carrier PA Multi-Carrier PA

    Combiner & Antenna

    Interface

    Digital IF Process

    BBU

    PA1

    TRX1

    PA2

    TRX2

    PA3

    TRX3

    PA4

    TRX4

    f1 f2 f3 f4

    Duplex & Antenna

    MCPA

    MTRX

    Interface

    BBU

    Digital IF Process

    f1~f6)

    f1~f6)

    SDR design is based on MCPA at the same frequency;

    MCPA provides flexible frequency optimization technology and better equipment integrity.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    7/65

    BS8700

    BS8900

    BS8800

    Distributed BTS BS8700, flexiblenetworking, 0 space requirement and

    rapid deployment , can be used for both

    indoor and outdoor coverage

    B8200

    R8860

    RSU40/RSU60

    +

    + =

    Indoor Marco BTS BS8800, can be

    installed in equipment room for indoor

    coverage

    RSU40/RSU60

    + =

    Outdoor Marco BTS BS8900, can be

    installed in cabinet for outdoor

    coverage, it can adapt to various

    environment

    =

    B8200

    B8200

    Micro BTS BS8906, provide Low-cost

    integrated solution for single-sectorcell.

    BS8906

    + =B8200

    RSU40/RSU60

    R8840

    SDR Base Station Family

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    8/65

    RRUBBU

    Indoor Macro

    Outdoor

    Macro

    MCPA-basedbroadband Radio

    Unit with multi-mode supported.

    Sufficient output power of HPA

    with lower power consumption.

    MicroTCA structureBase Band

    Unit with high reliability and

    easy expansion.

    High integrity & processing

    capability; upgrade to HSPA+ via

    software; minimum upgrade cost

    to support LTE.

    ZTE SDR 4 Key Features

    ZTE GSM/UMTS Dual-Mode SDR Family

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    9/65

    Agenda

    ZXSDR BTS Family Introduction

    ZXSDR BS8700

    ZXSDR BS8800 ZXSDR BS8900

    ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    10/65

    Hardware Architecture of BS8700

    B8200

    +R8840

    R8860

    BS8700

    Fiber

    BBU

    Radio UnitRadio Unit

    SA/

    SE

    CC

    BB

    (uBPG)

    FS R8860

    E1(75

    /120)

    / T1

    GE/FE

    Clock

    Data

    Control Signaling

    Antenna

    RRU

    CPRI

    The structure of BS8700 can express in the form of

    BBU+RRU, with Base band and RF modules separated.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    11/65

    B8200 accomplishes the following basic functions

    with RRU in Um/Uu, Abis/Iub and O&M interfaces. RRU and B8200 accomplishes UE access and radio link transmission

    including RF processing, channel coding and decoding, channel

    multiplexing and de-multiplexing, measuring and reporting, power

    control, transmit diversity, receiving diversity, calibration and

    synchronization. With Abis/Iub interface, RRU and B8200 connects with BSC/RNC and

    accomplishes the following functions including cell management,

    reporting BTS measurement information, broadcasting system

    Information, implementing access control from BSC/RNC, mobility

    management, radio resource management and controlling, FP

    processing and transmission management.

    With operating and maintenance interface, B8200 provides system

    management functions including configuration management, alarm

    management, status checking and system monitoring

    ZXSDR B8200 Introduction

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    12/65

    Based on Unified MicroTCA Platform

    Base Band Unit - ZXSDR B8200

    Volume:

    88.4482.6197mmHWD

    Weight: 8.75kg (full configuration)

    Typical Power Consumption :

    GSM 60W/12TRX

    WCDMA 80W / 6CS

    Power Supply: -48V DC

    Temperature Range: -2055

    Humidity Range: 5%95%

    2U

    482.6mm

    88.4mm

    GSM Processing Capability:

    60TRX (12TRX *5uBPGs )

    24 Cell / BBU

    UMTS Processing Capability:

    960CE/BBU(192CE/BPC*5)

    Throughput UL 75Mbps(15Mbps*5)

    Throughput DL 216Mbps(43.2Mbps*5)

    30CS/BBU

    Abis/Iub Interface:

    16*E1/T1

    1*FE/GE Electric/Optical(8 VLAN)

    To RRU: 12*1.25Gbps CPRI optical interface

    Performance Index

    Physical IndexInterface Index

    19 inch

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    13/65

    PM Board Introduction

    Power Module

    16 internal interface for +12V load power

    16 internal interface for +3.3V management power

    Measurement and protection of input over-voltage/under-voltage;

    Output over-current protection and load power management

    Power Module

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    14/65

    Board LED Color Meaning Description

    PM

    RUN GreenRunning

    Indicator

    Always on: The board is in reset state.Flashing at 1Hz: The board is normally running.

    Off: Self test fails.

    Alarm Red Alarm IndicatorOn: The board has an alarm.

    Off: The board has no alarm.

    HS BluePlugging/Unplug

    ging Indicator

    On: The board can be unplugged.

    Flashing: The board is being activated or

    deactivated.

    Off: The board cannot be unplugged.

    PM Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    15/65

    SA/SE Board Introduction

    Site Alarm Board

    Site Alarm Board/Site Alarm Extender Board(optional)

    Alarm monitor and rev control of no more than 9 fans;

    Signal monitor and interface lightning protection for the rack;

    Providing 6 input dry contact interfaces, 2 input /output dry contact interface;

    Providing 8 lines of E1/T1 interface

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    16/65

    Board LED Color Meaning Description

    SA/SE

    RUN GreenRunning

    Indicator

    Always on: The board is in reset state.

    Flashing at 1Hz: The board is normally running.

    Off: Self test fails.

    Alarm Red Alarm IndicatorOn: The board has an alarm.

    Off: The board has no alarm.

    HS BluePlugging/Unplug

    ging Indicator

    On: The board can be unplugged.

    Flashing: The board is being activated or

    deactivated.

    Off: The board cannot be unplugged.

    SA/SE Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    17/65

    SA JumpersJumperX5 is used to set E1/T1 transmission mode.

    TWO LSB POSITIONS OF X5

    TWO MSB POSITIONS OF X5

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    18/65

    CC Board Introduction

    GPS system clock & RF reference clock;

    Abis Iub interface function;

    Ethernet switch function, providing switch plan for signaling and media stream;

    Rack management

    Control & Clock Board

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    19/65

    Board LED Color Meaning Description

    CC

    HS BluePlugging/Unpluggin

    g Indicator

    On: The board can be unplugged.

    Flashing: The board is being activated or deactivated.

    Off: The board cannot be unplugged.

    RUN Green Running Indicator

    Always on: The board is in reset state.

    Flashing at 1Hz: The board is normally running.

    Off: Self test fails.

    Alarm Red Alarm Indicator On: The board has an alarm.Off: The board has no alarm.

    E0S Green E1/T1 statusindicator (link 03)

    Alternate flash for different links; the max 4 flashes per

    second; flashing at frequency of 5 Hz.

    The first second: one flash means Link 0 is normal and

    OFF means Link 0 is not in use.

    The third second: two flashes means Link 1 is normal and

    OFF means Link 1 is not in use.The fifth second: three flashes means Link 2 is normal

    and OFF means Link 2 is not in use.

    The seventh second: four flashes means Link 3 is normal.

    and OFF means Link 3 is not in use.

    Recycle. Each cycle lasts for eight seconds.

    CC Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    20/65

    Board LED Color Meaning Description

    CC

    E1S Green E1/T1 statusindicator (link 47)

    The same as E0S.

    E2S GreenE1/T1 status

    indicator (link 811)The same as E0S.

    E3S Green

    E1/T1 status

    indicator (link 12

    15)

    The same as E0S.

    MS Green Active/Standbystatus indicator

    On: The board is in active statusOff: The board is in standby status

    REF Green

    GPS antenna state

    or 2 MHz state,

    connection state ofSMA Interface on

    corresponding

    panel GPS

    Always on: The antenna feeder is normal.

    Always off: The antenna feeder and satellite are normal,

    in initialization state.

    Slow Flash (flashing at 1 Hz)): The antenna feeder is

    broken.

    Fast Flash (flashing at 2 Hz): The antenna feeder is

    normal but cannot receive satellite signal.

    Slowest Flash (flashing at 0.5 Hz): Antenna short circuit

    Quickest Flash (flashing at 5 Hz): No message is

    received at the initialization stage.

    CC Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    21/65

    Board LED Color Meaning Description

    ETH0 GreenAbis/Iub interface

    link state

    On: Physical link of Abis/iub network interface

    (optical or electrical) is normal.

    Off: Physical link of Abis/Iub network interface is

    broken.

    ETH1 Green

    Link state of

    ETH1 networkinterface

    On: Physical link of network interface is normal.

    Off: Physical link of network interface is broken.

    CC Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    22/65

    FS Board Introduction

    Fabric Switch Board

    Fabric Switch Module

    Baseband IQ data exchange;

    Providing interface between RRU and BBU

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    23/65

    Board LED Color Meaning Description

    FS

    RUN GreenRunning

    Indicator

    Always on: The board is in reset state.

    Flashing at 1Hz: The board is normally running.

    Off: Self test fails.

    Alarm Red Alarm IndicatorOn: The board has an alarm.

    Off: The board has no alarm.

    HS BluePlugging/Unplug

    ging Indicator

    On: The board can be unplugged.

    Flashing: The board is being activated or

    deactivated.

    Off: The board cannot be unplugged.

    FS Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    24/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    25/65

    Board LED Color Meaning Description

    UPBG

    RUN GreenRunning

    Indicator

    Always on: The board is in reset state.

    Flashing at 1Hz: The board is normally running.

    Off: Self test fails.

    Alarm Red Alarm IndicatorOn: The board has an alarm.

    Off: The board has no alarm.

    HS BluePlugging/Unplug

    ging Indicator

    On: The board can be unplugged.

    Flashing: The board is being activated or

    deactivated.

    Off: The board cannot be unplugged.

    UPBG Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    26/65

    Cable Connection of B8200

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    27/65

    ZXSDR R8860 Introduction

    Support the configuration of 5MHz/4.8MHz/4.6MHz channel interval;

    Multi-carrier support: GSM up to 6 carriers, UMTS up to 4 carriers, GSM/UMTSdual mode configuration;

    Multi-band support: 900M/1800MMHz

    Co-cabinet can support 4-antenna-receiving in 1 sector;

    Co-cabinet can support transmit diversity, without adding antenna achieving same

    receiving sensitivity;

    Co-cabinet can support non-continuous frequency configuration;

    Support RTWP report interval at 100ms and 2ms;

    Support transmit power reporting function for every carrier;

    Support over loading protection function for power amplifier;

    Support measurement, compensation and adjustment function for channel delay;

    Support transmit channel switching on/off function;

    R8860 software fault for itself will not affect the running of BBU and other R8860

    which connected to it.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    28/65

    Remote Radio Unit - ZXSDR R8860

    SDR R8860

    Carrier Configuration:

    Support GSM 1-6TRX or UMTS 1~4 CS

    Output Power60W /80W

    Receive Sensitivity:

    GSM -113dBm@sigle antenna

    UMTS

    -126.5dBm@sigle antenna

    -129.2dBm@dual antenna

    Frequency:

    900MHz, 1800MHz, 850MHz, 1900MHz

    Performance Index

    2*1.25G CPRI Optical interface

    Interface Index

    Volume(R8860): 500320172mmHWD

    Weight: 22.5Kg

    Typical Power Consumption:200W (6TRX)(900M)

    Power Supply: -48V DC

    Temperature Range:-40+55

    Protection Class:IP65

    Physical Index

    500mm

    35 power-efficient for GSM

    40% power-efficientfor UMTS.

    Support GSM and UMTS.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    29/65

    Remote Radio Unit Interface

    No Label Interface

    1 LC1BBU and RPU Interfaces / RRU

    concatenation interface

    2 LC2BBU and RPU Interfaces / RRU

    concatenation interface

    3 AISG AISG device interface

    4 Mon External device interface

    5 DC IN Power interface

    6 RXInterface to receive diversity RF

    cable

    7 RX/TXInterface to transmit / receive main

    diversity RF cable

    8 RXout Frequency expansion interface

    9 RXin Frequency expansion interface

    10 GND Machine Grounding

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    30/65

    Board LED Color Meaning Description

    RRU

    RUN Green Running Indicator

    Always on: The board is in resetting or starting status.

    Flashing at 1Hz: The board is normally running.

    Flashing at 5Hz: The board is downloading version.

    Off: Self test fails.

    Alarm Red Alarm Indicator

    Flash in 5Hz: critical or severe alarm

    Flash in 1Hz:normal or minor alarm

    Off: The board has no alarm.

    Link GreenOptical link

    indicator

    On: normal fiber connection

    Off: disconnected fiber

    Flash in 5Hz: consider this link as clock reference source,

    and phase-locked loop in fast capture status

    Flash in 0.25Hz: consider this link as clock reference

    source, and phase-locked loop in trace status

    RF OrangeRF working status

    indicator

    Off: without RF out put

    On: with RF out put

    RRU Indicators

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    31/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    32/65

    Agenda

    ZXSDR BTS Family Introduction ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    33/65

    ZXSDR BS8800 Introduction

    ZXSDR BS8800 (hereafter BS8800) is one of multi-carrier, multi-mode indoor

    macro base station in ZXSDR BTS series. BS8800 accomplishes UE access and radio link transmission including RF

    processing, channel coding and decoding, channel multiplexing and de-

    multiplexing, measuring and reporting, power control, transmit diversity, receiving

    diversity, calibration and synchronization.

    BS8800 connects with BSC/RNC and accomplishes the following functions

    including cell management, reporting BTS measurement information, broadcastingsystem Information, implementing access control from BSC/RNC, mobility

    management, radio resource management and controlling, FP processing and

    ATM transmission management.

    With operating and maintenance interface, BS8800 provides system management

    functions including configuration management, alarm management, status

    checking and system monitoring.

    BS8800 adopts standard 19 inches rack structure. The volume is main cabinet

    dimension: 950mm * 600mm * 450mm (H*W*D), auxiliary cabinet dimension:

    700mm * 600mm * 450mm (H*W*D).

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    34/65

    Integrated Indoor Macro Site - ZXSDR BS8800

    Radio Unit

    Baseband

    Unit

    Radio Unit:

    RSU40/RSU60

    Physical Index

    Volume: 950600450mmHWD

    (Main Cabinet)

    Weight: 135kg (Main Cabinet)

    Typical Power Consumption S666:735W(RSU60)

    Power Supply: -48V DC (-40~-57V DC)

    Performance Index

    GSMProcessing Capability:

    GSM: 60 TRX (12TRX * 5 BP boards

    24 Cell / BBU

    UMTS Processing Capability:

    Uplink and Downlink: 960CE

    UMTS: 30CS (6CS * 5 BPC boards)

    Receive Sensitivity:

    GSM -113dBm@single antenna

    UMTS-126.5dBm@sigle antenna

    UMTS-129.2dBm@dual antenna

    Interface IndexIub Interface:

    8*E1/T1(Can expand to 16)

    1*GE/FE Optical or 1*GE/FE Electrical

    To RRU: 12 *1.25Gbps CPRI Optical Interface

    SDR BS8800

    B8200

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    35/65

    Radio Unit of BS8800- RSU40/RSU60

    RSU40/RSU60 is an radio unit of BS8800 based on MCPA

    technology. It consists of MCPA (multi-carrier power module)

    module, transceiver module, and duplex filter LNA, and

    connects antenna via TX/RX, RX port.

    Compact and light

    Feeder Interface

    CPRI optical to

    BBU, or connect

    via SFP high-

    speed cable

    RX expand

    interfaceNumbe

    rInterface Interface Description

    1 Power Power supply interface

    2 AISG AISG device interface

    3 Mon External device interface45 TestDBG Debug, test interface

    6 TX RXInterface between BBU and

    RRU or RRU cascade

    7 RXoutRXin Frequency expand interface

    8 ANT

    Main and diversity antenna

    interface

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    36/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    37/65

    38

    Radio Unit:

    RSU40,RSU60

    Wiring Duct:

    Used to walk wiring in rack, such as

    fiber or SFP cable between BBU

    and RSU.

    Power Distribution Module:

    Passive power distribution unit

    Transmission Device: 1U slot, it can provide built-in

    transmission or microwave devices

    to save operators investment.

    Base Band Unit:

    2*B8200 can be placed in

    maximum FAN

    Used to perform heat dissipation for

    RSU modules, 6 fans in total

    BS8800 Hardware Structure

    950mm

    600mm

    450 mm

    Radio Unit

    Power

    Distribution Module

    Wiring

    Duct

    Transmission

    DeviceVentilation

    Base Band

    Fan

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    38/65

    Easy to stack and expand, lower upgrade cost for customers

    BS8800 - Easy to Stack, Easy to expand

    1650mm

    450 mm

    600mm

    Power Distribution

    Module

    Cable Chute

    Base Band Unit

    950mmPower Distribution

    Module

    Cable Chute

    Radio Unit

    Auxiliary Cabinet Fan

    Radio Unit

    Ventilation

    Main Cabinet

    950mm

    600mm

    450 mm

    600mm

    450 mm

    700mm

    Ventilation

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    39/65

    Agenda

    ZXSDR BTS Family Introduction ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    40/65

    ZXSDR BS8900 Introduction

    ZXSDR BS8900 (hereafter BS8900) is one of multi-carrier, multi-mode outdoor

    macro base station in ZXSDR BTS series.

    BS8900 accomplishes UE access and radio link transmission including RF

    processing, channel coding and decoding, channel multiplexing and de-

    multiplexing, measuring and reporting, power control, transmit diversity, receiving

    diversity, calibration and synchronization.

    BS8900 connects with BSC/RNC and accomplishes the following functions

    including cell management, reporting BTS measurement information, broadcasting

    system Information, implementing access control from BSC/RNC, mobility

    management, radio resource management and controlling, FP processing and

    ATM transmission management.

    With operating and maintenance interface, BS8900 provides system management

    functions including configuration management, alarm management, status

    checking and system monitoring.

    BS8900 adopts standard 19 inches rack structure, is composed of outdoor RF

    cabinets RC8910, RC8911, RC8931, site support cabinet BC8910, and battery

    cabinet PC8910.

    Integrated Outdoor Macro Site ZXSDR

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    41/65

    Integrated Outdoor Macro Site - ZXSDR

    BS8900

    Radio Unit:

    RSU40/RSU60

    Physical Index

    Volume: 1900600600mmHWD

    (Standard Configuration)

    Weight: 220kg ( with 3RSU)

    Typical Power Consumption:S666:725W(RSU60)

    Power Supply: -48V DC(-40VDC ~ -57VDC)

    Interface IndexIub interface:

    8*E1/T1(Can expand to 16)

    1*GE Optical or 1*GE/FE Electrical

    To RRU: 12 *1.25Gbps CPRI Optical interface

    SDR BS8900Base Band Unit:

    B8200Performance Index

    GSM Processing Capability:

    GSM: 60 TRX (12TRX * 5 BP boards)

    24 Cell / BBU

    UMTS Processing Capability:

    Uplink and Downlink: 960CE

    UMTS: 30CS (6CS * 5 BPC boards)

    Receive Sensitivity:

    GSM -113dBm@single antenna

    UMTS-126.5dBm@sigle antenna

    UMTS-129.2dBm@dual antenna

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    42/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    43/65

    Cabinet Appearance

    supporting cabinet + battery cabinet and radio cabinet

    Outdoor Radio Cabinets

    RC8910Radio Cabinet

    BC8910

    Supporting

    cabinetPC8910

    Battery Cabinet

    Power & Battery Cabinets

    RC8931

    Radio Cabinet

    RC8911

    Radio Cabinet

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    44/65

    BC8910 Structure

    Heat Exchange 4U

    Reserve Max. 6U

    BBU 2U

    AC Power 6U

    Heat Exchange 4U

    Reserve 6U/7U

    BBU 2U

    PDM 3U

    Lighting box 1U/2U

    Wiring Duct1U

    AC Supply DC Supply

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    45/65

    RC8911&RC8910 Structure

    RU

    Fan subrack

    PDM

    Storage battery

    Base

    Fan subrack

    PDM

    Breaker

    and surge arrester

    RU

    Base

    RC8911 RC8910

    RC8931&PC8910 S

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    46/65

    RC8931&PC8910 Structure

    RU

    Fan subrack

    Storage battery

    Base

    PDM

    Base

    Storage battery

    RC8931

    PC8910

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    47/65

    AC Configuration:BC8910+RC8911+RC8931

    Fan subrack

    BC8910

    RC8911

    RC8931

    Site support cabinet BC8910: used to

    accommodate power system, baseband pool unit,

    heat exchanger, and transmission device.

    Outdoor RF cabinet RC8911: used to accommodate RF unit and battery.

    Outdoor RF cabinet RC8931:

    used to accommodate RF unitand battery.

    Heat

    Exchanger

    BBU

    B121

    Fan

    subrack

    PDM

    RU

    Storage

    battery

    PDM

    RU

    Storage

    battery

    6U reserved

    space

    AC

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    48/65

    RC8910

    AC

    Configuration:BC8910+RC8910+RC8911+PC8910

    PC8910

    BC8910

    Heat

    Exchanger

    BBU

    B121

    Fan

    subrack

    PDM

    RU

    Storage

    battery

    Fan

    subrack

    PDM

    RU

    6U reserved space

    RC8911

    Outdoor RF cabinet RC8910:

    used to accommodate RF unit.

    Outdoor RF cabinet PC8910:

    used to accommodate battery.

    Storage

    battery

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    49/65

    AC Configuration:BC8910+PC8910+RRU

    PC8910

    BC8910

    R8860

    Heat

    Exchanger

    6U reserved space

    BBU

    B121

    Storage

    battery

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    50/65

    BC8910

    RC8910

    DC Standard Configuration:BC8910+nRC8910

    BBU

    Heat

    Exchanger

    RU

    PDM

    Fan

    subrack

    n=1~3

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    51/65

    52

    Multi-form, Minimal Requirement for Site Condition

    2

    3

    4

    1

    Place cabinets side by side

    RRU Remote Application

    Compact Configuration

    High Integration

    Built-in transmission,

    battery, power supply

    Maximal 8-hours

    power supply in full

    configuration

    Same size, volume and space for

    all cabinets

    Suitable for these scenarios such as

    ground-bearer or limited height

    No Power cabinet Compact

    Power and battery are optional

    based on different conditions.

    RRU makes RF as close to

    antenna as possible, minimizing

    feeder loss.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    52/65

    Agenda

    ZXSDR BTS Family Introduction ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    53/65

    ZXSDR BS8906 Introduction

    ZXSDR BS8906 (hereafter BS8906) is one of multi-carrier, multi-mode outdoor

    micro base station in ZXSDR BTS series.

    BS8906 accomplishes UE access and radio link transmission including RF

    processing, channel coding and decoding, channel multiplexing and de-

    multiplexing, measuring and reporting, power control, transmit diversity, receiving

    diversity, calibration and synchronization.

    BS8906 connects with BSC/RNC and accomplishes the following functions

    including cell management, reporting BTS measurement information, broadcasting

    system Information, implementing access control from BSC/RNC, mobility

    management, radio resource management and controlling, FP processing and

    ATM transmission management.

    With operating and maintenance interface, BS8906 provides system management

    functions including configuration management, alarm management, status

    checking and system monitoring.

    The BS8906 consists of BBU, RSU, FCE, PSU, APM\DPM, LPU\SDH\microwave

    IDU and so on.

    I t t d Mi Sit ZXSDR BS8906

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    54/65

    Integrated Micro Site - ZXSDR BS8906

    Radio Unit:

    RSU40/RSU60

    Physical IndexVolume: 600 320 480 mmHWD

    Weight: 52kg

    Typical Power Consumption S4: 300W (RSU60)

    Power Supply: -48V DC (-40~-57V DC)

    Performance Index

    Processing Capability:

    GSM: 6TRX,UMTS 4CS

    Base Band Processing Capability:

    Same as B8200

    Receive Sensitivity:

    GSM -113 dBm@sigle antenna

    UMTS-126.5dBm@sigle antenna

    Frequency

    900MHz, 1800MHz, 850MHz, 1900MHz

    Interface IndexIub Interface:

    8*E1/T1(Can expand to 16)

    1*GE/FE Optical or 1*GE/FE Electrical

    To RRU: 12 *1.25Gbps CPRI Optical Interface

    SDR BS8906

    B8200

    BS8906 can be connected with RRU

    for outdoor BBU solution.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    55/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    56/65

    Agenda

    ZXSDR BTS Family Introduction ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Princip le

    ZXSDR BTS Operation and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    57/65

    Hardware Architecture

    BBU performs Abis/Iub interface functions, signaling processing,baseband

    processing, remote and local O&M functions, working status monitoring, andalarm functions.

    RRU performs terminal access and RF link transmission function through

    Um/Uu interface.GPS antenna

    SAE1/T1

    BSC/RNC

    IQ

    switching

    IQGE

    RRU

    FAM

    PM

    Abis/Iub

    Clock

    GE/FE

    GE

    UBPG/ BPC

    FS GE

    switching

    CC

    Fiber

    BBU

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    58/65

    Software Architecture

    OSS

    G SM Function

    UMTS Function

    NOP

    OMC-B

    SCS OAM DBS BRACSBRS

    VOS

    Sche. Timer Moni. CPP Excep Mem BBX File DBG

    Windows

    Hardware (BSP)

    VxWorks

    LMT

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    59/65

    The operating support layer provides the functions of OSS, OAM, DBS, BRS, BRACS, and

    SCS to serve to different BTS mode. OAM (Operating and Maintenance) is to provide the configuration, alarm and

    performance measurement function.

    DBS (Data Base Sub-system) is the database system.

    BRS (Barrier Sub-system) is for protocol stack processing.

    BRACS (Barrier Access Control Sub-system) is to control the access to bear layer.

    SCS (System Control Sub-system) is to control the power supplying andactive/standby switching.

    OSS (Operation Support Sub-system) is the support layer in this entire framework, which is

    a hardware irrespective platform for running software and provides basic functions like

    scheduling, timer, memory management, communication, sequencing control, monitoring,

    alarming and logging. Detects the external and internal environment temperature in real

    time.

    BSP (Board Support Package) supports the information routing to the GSM and public

    parts in the application layer.

    VxWorks is the operation platform communication to the hardware components.

    Software Architecture

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    60/65

    Agenda

    ZXSDR BTS Family Introduction ZXSDR BS8700

    ZXSDR BS8800

    ZXSDR BS8900 ZXSDR BS8906

    ZXSDR BTS Work Principle

    ZXSDR BTS Operat ion and Maintenance

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    61/65

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    62/65

    Maintenance Functions

    FaultManagement

    NE (RAN)

    3rd Party

    NMS/OSS/BSS

    CORBA SNMP FILE ASCII DB

    PerformanceManagement ConfigurationManagement

    Log

    Management

    Security

    Management

    Northbound

    Interface

    Version

    Management

    System

    Management

    Topology

    Management

    FM

    NE (CN)

    Southbound

    Interface

    PM CM IM SM

    NE

    EMS

    NMS/OSS/

    BSS

    NetNumenTMM31

    FM FM/PM/CM/IMFM/PM/CM/IM FM FM/PM/CM/IM

    FM PM CM IM SM

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    63/65

    The BSS provides a transparent channel to implement operation and maintenance

    information interaction between NetNumen M31 and the BTS. Management of the BSC and

    the BTS adopts unified client interface for unified security management and operation log.

    And it has a unified service management interface. NetNumen M31 also supports

    CORBA/SNMP Itf-N interface to be integrated with third-part NMS.

    Maintenance Functions

    Version Management

    With this function, users can check the versions of the software and hardware running at

    the foreground. The background provides a software downloading system for software

    upgrade at the foreground. Before downloading, warehousing processing is required, that is,

    copying the version file to the server and registering to the server.

    Fault Management

    With this function, users can check the versions of the software and hardware running at

    the foreground. The background provides a software downloading system for software

    upgrade at the foreground. Before downloading, warehousing processing is required, that is,

    copying the version file to the server and registering to the server.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    64/65

    Maintenance FunctionsConfiguration Management

    Configuration management implements equipment configuration and radio configuration.

    Log Management

    Any operation performed by an operator is recorded automatically by the system. Thus, the

    operation maintenance personnel can query historical operation records in some special

    cases (such as abnormal system operations).

    Security Management

    Security management is implemented through user management and user group

    management. The user element includes the user name and password, as well as which

    user groups the user belongs to. The user group element includes the user group name

    and authority information.

    Performance Management

    Performance management is to measure, report and make statistics of the System

    performances.

  • 8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67

    65/65