7
G-ULTRA WIRING DIAGRAMS GSM DEVICES Centurion Systems (Pty) Ltd www.centsys.com

G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

  • Upload
    others

  • View
    118

  • Download
    7

Embed Size (px)

Citation preview

Page 1: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

G-ULTRA WIRING DIAGRAMS

GSM DEVICES

Centurion Systems (Pty) Ltd www.centsys.com

Page 2: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

G-ULTRA

D-Series Controller

Possible Activations

• Trigger Open• Pedestrian Open• Free Exit / Keep Open• Holiday Lock

Possible Notifi cations

• Gate Open / Closed• Gate Opening / Closing• Gate Standing Open• Mains Failure• Battery Low• Multiple Collisions

RELAY 1

LCK

+1

2V

CO

M

STA

TUS

FRX

PED

TRG

RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

1. Wiring a G-ULTRA into a D-Series Controller

FIGURE 1

Page 3: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

IN1GATEDATGND

+

+12

+ -- KEYPADSIRENSTROBE16VAC

2. Wiring a G-ULTRA into an Electric Fence Controller

FIGURE 2

G-ULTRA RELAY 1 RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

Possible Activations

• Arm / Disarm

To program the Strobe to Status:

JVA Keypad, Press:1. “INSTALLER PIN”*0#2. 2202#3. *#

Nemtek Keypad, Press:1. “INSTALLER PIN”*0#2. 101# OR 0011# (Model Dependant)3. *#

• The Status and alarm inputs must have three seconds fi lter time confi gured on the G-UTRA

• The strobe output on the energiser needs to be programmed for the armed status notifi cation to be sent via the G-ULTRA

• Using “IN1” via the G-ULTRA will bypass the key-switch function on the energiser

Possible Notifi cations

• Arm Status• Alarm Notifi cations

Electric Fence control board

GND

+12VDC

NONO CO

M

++ --

NC

SirenRelay

StrobeRelay

NC

KEY

SW

ITCH

KEY

SW

ITCH

ALA

RM

STA

TUS

Page 4: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

Z1GND C

3. Wiring a G-ULTRA into an Alarm System

FIGURE 3

G-ULTRA RELAY 1 RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

Possible Activations

• Arm / Disarm

Alarm programming:

PGM1: Armed StatusPGM2: Siren FollowZ1: Keyswitch Latched Arm / Disarm

Possible Notifi cations

• Arm Status• Intruder / Siren

Alarm Panel

GND

+12VDC

KEY

SW

ITCH

KEY

SW

ITCH

GN

D

ALA

RM

STA

TUS

The Alarm Panel PGMs must activate to “GND”. However, if the Alarm Panel only supports positive activations, then relays must be used between the Alarm Panel and the G-ULTRA to change the activation to “GND”.

Page 5: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

G-ULTRA

External pull-down resistor (10kΩ)

D-Series Controller

Possible Activations

• Trigger Open

Possible Notifi cations

• Gate Open / Closed• Gate Opening / Closing• Gate Standing Open• Mains Failure• Battery Low• Multiple Collisions

RELAY 1 RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

4. Wiring a G-ULTRA into a D-Series Controller via a WiZo

FIGURE 4

WiZo

WiZo

IN

IN

NO

NO

COM

COM

NC

NC

GND

10k

+12VDC

TRG

TRG

GA

TES

TATU

S

GA

TES

TATU

S

Page 6: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

IN1GATEDATGND

+

+12

+ -- KEYPADSIRENSTROBE16VAC

5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos

FIGURE 5

G-ULTRA RELAY 1 RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

Possible Activations

• Arm / Disarm

To program the Strobe to Status:

JVA Keypad, Press:1. “INSTALLER PIN”*0#2. 2202#3. *#

Nemtek Keypad, Press:1. “INSTALLER PIN”*0#2. 101# OR 0011# (Model Dependant) 3. *#

Possible Notifi cations

• Arm Status• Alarm Notifi cations

G-ULTRA

Electric Fence control board

GND

+12VDC

WiZo WiZo

WiZo WiZo

IN IN

IN IN

NO NO

NO NO

COM COM

COM COM

NC NC

NC NCNONO CO

M

++ --

NCNC

GND+12VDC

KEYSWITCH

KEYSWITCH

ALARM

STATUS

STA

TUS

ALARM

• The Status and alarm inputs must have three seconds fi lter time confi gured on the G-ULTRA

• The strobe output on the energiser needs to be programmed for the armed status notifi cation to be sent via the G-ULTRA

• Using “IN1” via the G-ULTRA will bypass the key-switch function on the energiser

Page 7: G-ultra Wiring Diagrams - Centurion Systems Wiring... · 5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos FIGURE 5 G-ULTRA RELAY 1 RELAY 2 GND IO1 IO2 IO3 IO4 NO COM

Z1GND C

6. Wiring a G-ULTRA into an Alarm System via WiZos

FIGURE 6

G-ULTRA RELAY 1 RELAY 2

GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC

Possible Activations

• Arm / Disarm

Alarm programming:

PGM1: Armed StatusPGM2: Siren FollowZ1: Keyswitch Latched Arm / Disarm

Possible Notifi cations

• Arm Status• Intruder / Siren

Alarm Panel

GND

+12VDC

WiZo

WiZo

IN

IN

NO

NO

COM

COM

NC

NC

WiZo

INNOCOMNC

WiZo

INNOCOMNC

KEY

SW

ITCH

KEY

SW

ITCH

ALA

RM

ALA

RM

GN

D

STA

TUS

STA

TUS

GND+12VDC

The Alarm Panel PGMs must activate to “GND”. However, if the Alarm Panel only supports positive activations, then relays must be used between the Alarm Panel and the G-ULTRA to change the activation to “GND”.