BiWire Ultra fire system Product brochure Be less conventional

Be less conventional - Cooper Fire Ultra can reduce wiring requirements by up to 50%, ... Fault & Interlink Relay Type: Volt-Free, Single Pole Double Throw, Rating: ... Moeller, and

Embed Size (px)

Citation preview

BiWire Ultra fire systemProduct brochure

Be lessconventional

We deliver:• Electrical solutions that use less energy, improve power reliability

and make the places we live and work safer and more comfortable

• Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power

• Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently

• Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions

Discover today’s Eaton.

Powering business worldwideAs a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses.

Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably.

We provide integrated solutions that help make energy, in all its forms, more practical and accessible.

With 2014 sales of $22.6 billion, Eaton has approximately 100,000 employees around the world and sells products in more than 175 countries.

Eaton.com

Energizing a worldthat demands more.

ECH1-788_Eaton_Catalog_English_A4_single_page.indd 1 2/6/15 11:18 AM

BiWire Ultra can reduce wiring requirements by up to 50%, it’s quicker to install compared to a conventional system, meaning faster turnaround time for new builds.

BiWire Ultra fire system

BiWire Ultra, how it works Reducing cable run and installation timeEaton’s BiWire Ultra is a two-state system that allows detection and alarm circuits to share the same cable.

It’s as simple to operate and install as a standard conventional system but BiWire Ultra allows detectors, sounders and beacons to all share the same zone wiring, delivering significant savings in both cable and installation costs.

Installation with BiWire Ultra is more economic, a two zone system only requires two circuits. A conventional fire system would need four circuits to do the same job, as each zone would require a circuit for detection and another circuit for notification (sounder & beacons).

Reduces cable by approx 50%

Zn2 Zn3

Zn1 Zn4

BiWire UltraPANEL

BiWire Ultra fire alarm system

Standard conventional fire alarm system

Zn2 Zn3

Zn1 Zn4

CONVENTIONALPANEL

Lower cabling costs

Lower installation costs

Quicker installation

Simpler commissioning and maintenance

Less complex to install than addressable systems

We deliver:• Electrical solutions that use less energy, improve power reliability

and make the places we live and work safer and more comfortable

• Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power

• Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently

• Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions

Discover today’s Eaton.

Powering business worldwideAs a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses.

Eaton’s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably.

We provide integrated solutions that help make energy, in all its forms, more practical and accessible.

With 2014 sales of $22.6 billion, Eaton has approximately 100,000 employees around the world and sells products in more than 175 countries.

Eaton.com

Energizing a worldthat demands more.

ECH1-788_Eaton_Catalog_English_A4_single_page.indd 1 2/6/15 11:18 AM

3EATON - BIWIRE ULTRA FIRE SYSTEM

BiWire Ultra fire systemHow it works

Benefits:

When to specifyBiWire Ultra is a cost-effective, easy to install solution for a variety of applications.

It's modern design and a simple interface make it the system of choice for small to medium sized installations.

Schools Class change facility as standard

Retail Modern aesthetics

Healthcare Easy to use and test

Industrial EN54-23 beacons for high noise areas

Office Buildings Reduced disruption

Small Nursing Fit with expansion card for controlling Homes door release devices

4 EATON - BIWIRE ULTRA FIRE SYSTEM

BiWire Ultra fire systemWhen to specify

• EN54-23 sounder beacon option• 2, 4 and 8 zone variant, tailored to the size and

need of the building• Back up battery supplied with panel• Supports an expansion card for FRE and FPE• Simple intuitive interface• Up to 52 devices per zone• Modern aesthetics• Battery included• Interlink relay• EN54- 2&4 compliant

Supporting up to 52 devices per zone, all panels in the range have the facility to flash detector LED’s to facilitate the location of any wiring faults.

The BiWire Ultra systemEaton’s BiWire Ultra system can support up to 416 devices* in total. Certified to EN54 parts 2 and 4 and is designed to meet the recommendations of BS5839.*8 Zone panel

5EATON - BIWIRE ULTRA FIRE SYSTEM

Fault warning

Status indication

Multifunction buttons

Easy test

DescriptionHeight (mm)

Width (mm)

Depth (mm)

Complete Panel 336 375 134Backbox (for flush mount) 273 338 88

BiWire Ultra fire systemComplete system

BiWire Ultra 4 zone panel

Panel dimensions

The BiWire Ultra detector can be configured to one of 5 settings including 3 heat detector modes, helping to prevent false alarms in areas with known high levels of dust, fumes, steam or smoke.

• 360° indicator LED using lightpipe technology

• Configurable detector• Optical detector• Photo-thermal detector• 1 of 3 heat detector modes

(A1R, BS, CS) Rate of Rise – 60ºC Fixed heat - 77ºC Fixed heat - 92ºC

• Certified for use in all 5 modes.• Dia: 104 D1: 55 D2: 42

Wall sounder VAD

• High output sounder• EN54-23 certified Visual Alarm Device• Sounder provides up to 99 +/- 3dB(A)• Low current – Sdr Only = 2.6mA, AV = 8.7mA• 3 tones• IP 21C• H: 110 W: 110 D: 100

Compatible with BiWire Ultra - EN54-23 beacons

Relay ModuleThe BiWire output relay module is designed to provide a simple means of interfacing BiWire systems with external equipment such as door retainers.

• IP40 rated• 24V dc and 230V ac variants• Easy to fit• H: 129 W: 180 D: 60

• High output sounder• EN54-23 certified Visual Alarm Device• Sounder provides up to 99 +/- 3dB(A)• Low current – Sdr Only = 2.6mA, AV = 8.7mA• 3 tones• IP66• H: 106 W: 106 D: 91

Weatherproof wall sounder VAD

The new BiWire Ultra system offers innovative devices with the latest technology, including a unique set of visual alarm devices (VADs) that comply with EN54-23, the latest beacon standard.

Surface/flush mounted and weatherproof call pointBased on the tried and tested Eaton design, the call point can be mounted flush into the wall or surface mounted.

• Fast clip on cover• High visibility LED• Complete with test key• A comprehensive range of ancillaries.• H: 87 W: 87 D: 53 (surface) 36 (flush)• IP65 rated (EF203BWCPWP)

5 in 1 detector• EN54-23 certified Visual Alarm Device• Designed for use with the Eaton 5 in 1 detector.• Ceiling fix, ideal where wall cabling is not an option• Can operate as a standalone beacon / sounder beacon when fitted

with cover plate• Sounder provides up

to 90 +/- 3dB(A)• 3 tones• IP21C• Dia: 115 D1: 46 D2:74

Detector Base Sounder and Sounder VAD

6 EATON - BIWIRE ULTRA FIRE SYSTEM

Dia

D1D2

W

H

D

BiWire Ultra fire systemCompatible devices

Dia

D1 D2

Dia

D1D2

Dia

W

H

DW

H

D

W

H

D

H

W

D

7EATON - BIWIRE ULTRA FIRE SYSTEM

2 zone panel 4 zone panel 8 zone panelEFBW2ZONE EFBW4ZONE EFBW8ZONE

Number of Zones 2 4 8

Devices Per Zone Max of 32 Detectors and Manual Call points, Zone loading cannot exceed 200mA in alarm

Maximum Loading Per Zone 200mA

Standby Zone Voltage Min: 22V DC, Max: 24V DC

Alarm Zone Voltage Min: 31V DC, Max: 33V DC

Fuse Protection Per Zone 250mA PTC

End of Line Termination EOLM-3 Only(Do not use EOLM-1 or EOLM-2)

Fire, Fault & Interlink Relay Type: Volt-Free, Single Pole Double Throw,Rating: 30V DC, 1A,Fuse 1.1A PTC

Auxiliary Output V: 0V DC (Standby)/30V DC (Alarm +/-10%),Imax: 50mA,Fuse: 50mA PTC

Class Change Short circuit to trigger input, open circuit to clear input

Mains rating 230V Ah +10%/-15% 50Hz

Battery rating 2 x 12V 5Ah

Changeable power fuses Mains 1A anti surge

Battery 6-3A anti surge

Repeater Port Yes

Environmental

Operating temperature -5 °C to +40°C

Relative humidity 93% +/-3% non-condensing

IP Rating IP30

Physical

Weight (excluding batteries) 2.25kg

Material PC ABS Front and Rear

Cabling

Cable access 29 x 20mm drill positions Slots for rear cable entry

Cable type Firetuf FT120 / FP200 2 core 1.5mm, 2 screened fire rated cable, 500m (max per zone)

Specification

BiWire Ultra 2, 4 and 8 zone panel

DetectorsDetector base sounder EF5021BWSDetector base sounder VAD EF5021BWSB

Standard base FXN520Cover for sounder detector base CASCWall sounder & wall sounder VADWall sounder EF009

Wall sounder, weatherproof EF009WP

Wall sounder VAD EF009SBWall sounder VAD, weatherproof EF009SBWPExternal relayBiWire Ultra external Relay 24V BWEXTR24VBiWire Ultra external Relay 230V BWEXTR230V

Description Code2 zone BiWire Ultra panel EFBW2ZONE4 zone BiWire Ultra panel EFBW4ZONE8 zone BiWire Ultra panel EFBW8ZONERepeater panel EFBWREPEATEREnd of line module BWEOLM2 zone relays + FRE/FPE BW0B2Z4 zone relays + FRE/FPE BW0B4Z8 zone relays + FRE/FPE BW0B4ZCallpointsBiWire Ultra Callpoint EF201BWCPBiWire Ultra Callpoint weatherproof EF203BWCPWPDetectorBiWire Ultra detector 5 in 1 EFBW5IN1DET

BiWire Ultra fire systemTechnical specification & product codes

Product codes

Eaton,Cooper Lighting and Safety Ltd,Wheatley Hall Road,Doncaster,South Yorkshire,DN2 4NBUnited KingdomTel: +44 (0)1302 303 999Fax: +44 (0)1302 303 333Email: [email protected]: www.cooperfire.com

© 2015 EatonAll Rights Reserved Printed in UK Publication No. EFBWBR21215

Changes to the products, to the information contained in thisdocument, and to prices are reserved; so are errors and omissions.Only order confirmations and technical documentation by Eaton isbinding. Photos and pictures also do not warrant a specific layout orfunctionality. Their use in whatever form is subject to prior approvalby Eaton. The same applies to Trademarks (especially Eaton, Moeller,and Cutler-Hammer). The Terms and Conditions of Eaton apply, asreferenced on Eaton Internet pages and Eaton order confirmations.

Eaton is a registered trademark.

All other trademarks are propertyof their respective owners.