8
G-EMR XEA Montageanleitung Mounting instructions 230 V AC < 1 m 2 1 230 V AC 2 m 0,5 m > 1 m 2 3 3 4 1 WN 059328 45532 – 2017-10 2.4

G-EMR XEA · 2019. 4. 29. · /RM-N 210 12 7 2 150 35, 5 1 5 Ø 12 (230 A C) Ø 8 210 12 7 2 10 7 16 0 43 81 15 43 16 16 81 2 8 4 3 16 16 ≤ 16 ≤ 26 ≥ 950 ≥ 950 ≥ 10 ≥

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • G-EMR XEA

    Montageanleitung Mounting instructions

    230 V AC

    < 1

    m

    21

    230 V AC

    2 m0,5 m

    > 1

    m

    2

    3

    3

    4

    1

    WN 059328 45532 – 2017-10

    2.4

  • Montage Installation

    MontageanleitungMounting instruction

    14

    2

    42

    8

    16

    08

    5

    Ø

    12

    (2

    30

    VA

    C)

    Ø

    8

    HT/R

    M-N

    210

    12

    7

    2

    15

    03

    59

    ,5

    915

    42

    8

    5

    Ø

    12

    (2

    30

    VA

    C)

    Ø

    8

    HT/R

    M-N

    210

    12

    7

    2

    15

    03

    59

    ,5

    915

    10

    716

    04

    3

    81

    15 43

    1616

    81

    28 43

    1616

    ≤ 16 ≤ 26

    ≥ 95

    0

    ≥ 95

    0

    ≥ 10 ≥ 10

    1 Montage

    2 G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    4.1 A

  • Montage Installation

    MontageanleitungMounting instruction

    14

    2

    42

    8

    16

    08

    5

    Ø

    12

    (2

    30

    VA

    C)

    Ø

    8

    HT/R

    M-N

    210

    12

    7

    2

    15

    03

    59

    ,5

    915

    42

    8

    5

    Ø

    12

    (2

    30

    VA

    C)

    Ø

    8

    HT/R

    M-N

    210

    12

    7

    2

    15

    03

    59

    ,5

    915

    10

    716

    04

    3

    81

    15 43

    1616

    81

    28 43

    1616

    ≥ 95

    0

    ≥ 95

    0

    ≥ 10 ≥ 10

    ≤ 26

    ≤ 16

    3G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    4.1 B

  • Montage Installation

    MontageanleitungMounting instruction

    230 V AC

    HT

    RM-N

    b

    230 V AC

    HT

    RM-N

    b

    5x30M5x20

    5x30M5x20

    1.

    1.

    2.

    2.

    4 G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    4.2

    A

    B

  • Montage Installation

    MontageanleitungMounting instruction

    5x60M5x50

    M5x36

    4,5x45M5x40

    1.

    2.

    3.

    4.

    5G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    A

    180°

    5x60M5x50

    M5x36

    ≈ 15

    4,5x45M5x40

    1.

    2. 4.

    3.

    B

    4.3

    5.

    6.

    7.

    8.

  • Montage Installation

    MontageanleitungMounting instruction

    230 V AC

    L

    PE

    N

    HT

    RM-N

    9

    ON

    1 2 3 4

    Reset

    RESET

    ON

    1 2 3 4

    5.

    1.

    1.

    2.

    2.

    3.4.

    1. 1.

    2.

    2 In Betrieb nehmen

    6 G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    4.5

    5.1

    5.2

  • Montage Installation

    MontageanleitungMounting instruction

    2,5

    Nm

    Nm

    1.

    2.

    1.

    3.

    3.

    1.

    2.

    4.

    5.

    3.

    ≈ 140°

    80°

    1.

    2.

    3.1

    3.2

    3.3

    7G-EMR XEA 2017-10WN 059328 45532

    dormakaba

    5.3

    5.4

    5.5

  • dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Deutschland T: +49 2333 793-0 F: +49 2333 793-4950 www.dormakaba.com

    918/5

    10-15 cm

    230 V AC

    LED 2

    LED 1

    RESET

    1.

    2.

    2.

    2.

    3.

    3.

    1.

    Änd

    erun

    gen

    vorb

    ehal

    ten/

    Sub

    ject

    to

    chan

    ge w

    itho

    ut n

    otic

    e

    5.7

    6