13
R Ver. 1.5 Kawamoto’s Pump Series From Intake, Circulation, Booster, Drainage and Wastewater treatment to Production equipment Lift up, Booster, Circulation, and Drainage Water supply equipment / Small regional drinking water /Energy-saving inverter Seawater / Hot water (Hot spring) Production equipment Bringing valuable "water" to you KAWAMOTO PUMP

From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

R

Ver. 1.5

Kawamoto’s Pump Series

From Intake, Circulation, Booster, Drainage and Wastewater treatment to Production equipment

Lift up, Booster, Circulation,and Drainage

Water supply equipment / Small regional drinking water /Energy-saving inverter

Seawater / Hot water (Hot spring) Production equipment

Bringing valuable "water" to you KAWAMOTO PUMP

Page 2: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

17

3 19 25 30 34 35

6 12 17 19 21 35

3 4 18 19 28 34

3 18 19 24 26 28 34

3 13 15

25 30

1 13 15 23 24 283 1910 25 28 34

3 19 41

3 13 42

3 13 42

3 10 33 34

2 3 10 25 33 34

3 9 26 28 30 33 34

9 25 30 33 34 39

3 26 28 33 34

9 23 25 30 34

3 9 23 25 30

29 31

5 7 22

5 7 22 29 31

9 11 20 23 25 30 38

9 11 20 23 25 30 38

9 11 20 23 25 30 38

20119 23 25 30 38

11 20 23 24 28 30 38

11 20 23 30 38

1 8 14 19 20 25 38

8 11 25 38

8 11 25 38 39

1 8 14 20 25 38

1 8 18 19 25

1 8 16

36 37 38

36

6 36 37 38

6 36 37

6 11 12 18 19

6 11 12 18

6 11 12 18

6 11 12 18

11 20 23 24 28 38

9 13 15

17 30 38

9 13 15 17 30 38

9 13 15

17 30 38

6 12 15 26225 7 29 31

10 39

3 10 39 44

10 38

39 43

2 8 10 37 38

388 10 25

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40 41 42 43 44

3 26 30 34

26193 28 34

3 26 33 34 P9

FS type

KURH type23

Deep well

USM (H) type

P3

P3

P4

P4

P5

P5

P7

P6

P6

P11

P10P9

P9

P9 P11

P13

P13

P13

P13

P13

P13

P8

P8

P12

P12

P12

P12

P14

P14

P14

P14

P16

P17

P18

P16

P15

P15

P15

P21

P21

P21P21

P21

P3,21

P21

P20

P20

P20

P20

P20

P20

P20

P20

P20

P20

P21

Pic:NR type

List of model

P12

P12

P12

P12 P19

P19

P19Pic:NFG type

P16

P19

P18

P18

Kawamoto products with this mark areproducts with excellent energy-savingand environmentally friendly features.

Well water lift up

Hot water supply Industry

General drainage

Drainage of sump and waste water

Sea water intake

For various wastewater drainage

House hold

Preventing red discolourment water supply

Sprinkling / generalservice water

Self priming type

Booster from receiver tank Circulation

Septic tank drainage Drinking water Snow melting

Cold and hot water circulation

Cooling water

Filtration and circulation (swimming pool etc.)

Hot springHot waterboosting

Energy-savinginverter

Factory production equipment

Fuel oil

Small regionaldrinking water

Setting for machinery equipment

IndustrialFishery/Fishprocessing plant

Building equipment

Booster from elevated tank Industrial water

Emergency Drinking Water Supply Equipment

General water supply

General waterlift up

Residual waterdrainage Agriculture Pit drainage

Water supply to buildings and factories

Building drainage

Automatic water supply from mounted reservoir / underground reservoir

Heating Fire fightingDeionized water Air blower

Centrifugal / Multistage pumpCascade / Oil pump

Fire fightingpump

Submersible clean water

pump

Submersible Sump Pump

Energy-saving inverter

Stainless steel submersible pump

Stainless steel hot water booster unit

Constant pressure automatic booster pump

Self-priming plastic pump

Titanium submersible pump

Water seal vacuum pump unit

Coolant Pump

Vortex Blower

Pure water electrolysis water

Hand pump

PSS(2) type

FV(D)- C 4C type

KTU(2) type

KTK-W · KTY-W type

KTGF · KTGDF type

BUW type

VU4 type

AU4 type

GSN(2)-C type

KTY-ET type

GE-2M type

HDS type

GSZB2 type

NFH2 type

KFEH type

KZB type

DW type

GSP3 4 type

WUZ2 3 -G type

GSP3 4 type

RA type

NFG · JFG type

RCD J type

SFR(W) · SFRH(W) type

NFD(N)2 typeGES-4M type

KR4 5 -C type CS-C type

OC(K) type

OCH type

US2 type

USM(H) type

KUR2 3 type

KF Series KF2-R type

KF Series KFE 2 -T type

KF Series KFE 2 -A·P type

GE-C type

KVS type

GSO2 3 -C type

PE(2) type

KTK-C type

KTY typeWUP3-G type

WUO(3)-G type

WUZ2 3 -G type

ZU3 J type

KF Series KF2-H type

USFE type/LFE type

BU4 type

KUF type

USF2 type/LF type

NF3 type

UF(L)2 type

UFE type

JF type

NR · N3-N type

KF2-R type

KF2-H type

KVF-G type

KFED-R type

NDP2-G type

KDP3 type

SDP-R type

KFED D2 type

KFE-A · P · T type

KDP3-D W type

Stainless steel & Variable speed control booster unit

Direct connection with water main booster pump

Stainless steel household automatic water supply pump

Hot water auxiliary boosting

equipment

Energy-saving inverter

Household

Water supply equipment / Small regional drinking

water unit

Seawater /Special purpose

For hot water (hot spring) pump series

Equipment pump

Small booster pump unit

P7

P7

P8KS type

T(N) type

TVS type

The standard configuration for pump systems with that those with an output of 0.75 kW or more are equipped with a Premium efficiency motor (IE3 efficiency),and those with an output of 0.4 kW or less are equipped with a standard efficiency motor. Please consult your distributer for the motor specifications.

1 2

Page 3: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

( )

Self-priming turbine pump

Centrifugal / Multistage pump series

Liquid pH5.8~8.6 Clean water 0~45˚C (no freezing)

Suction total head (20˚C) -6mImpeller BronzeShaft SUS403 or SUS304Casing Cast iron + Nylon coating

Shaft sealing Mechanical sealType TEFC outdoor

PhaseThree phase2 pole

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

Efficiency Premium efficiency (IE3)*

Efficiency Premium efficiency (IE3)*Indoor/Outdoor

Installation Outdoor installation available (expect 0.4kW single phase model)

* 0.75kW or more is equipped with a Premium efficiency motor.

Liquid Clean water 0~40˚C (no freezing)

Suction total head(20˚C)

Bore size 25mm/-3mBore size 32mm/-3.5m (60Hz: -5m)Bore size 40~65mm/-5.5m (60Hz: -6m)Bore size 80~150mm/-6mCast ironSUS403(portion contacting liquid)Materials

Impeller

Cast ironCasing

Shaft

Shaft sealing Gland packing, Mechanical seal

Type TEFC outdoor (single phase 0.4kW or less has ODP motor)

PhaseThree phase4 pole

Speed 50Hz:1,500min-1

60Hz:1,800min-1

Efficiency Premium efficiency (IE3)*Installation Indoor*0.75kW or more is equipped with a Premium efficiency motor.

Materials

Motor

Liquid Clean water 0~40℃(no freezing)

Suction total head*1

(20˚C)

Bore size 40mm/0.4kW/-8.5m(Max. -9m)Bore size 40mm/0.75kW/-8m (Max. -9m)Bore size 50mm/0.75, 1.5kW/-8m (Max. -8.4m)

Impeller Bronze or Stainless Cast Steel or ResinShaft SUS304 (portion contacting liquid)Casing Cast iron

Shaft sealing Mechanical sealVariation TEFC outdoorPhase Three phase

Speed50Hz:3,000min-1

60Hz:3,600min-1

Efficiency Premium efficiency (IE3)*2

Installation Indoor

Motor

Materials

34

Sister modelsCast iron typeSelf-priming turbine pump

GS -CtypeBore : 25~100mmMotor : 0.25~7.5kW

23

Sea water / Clean water 0~60˚C (no freezing)[Clean water]:pH5.8~8.6 chloride ion concentration 200mg/L or less[sea water]:pH7.8~8.2 chloride ion concentration 19000mg/L or lessSand content 1000mg/L or less

Suction total head (20˚C) -7m (0.4kW or Bore size 80mm model:-6m)Resin

ResinMaterials

Impeller

Shaft SUS316CasingType

MotorTEFC outdoor

Phase Three phase

Installation*0.75kW or more is equipped with a Premium efficiency motor.

Motor

Liquid

3

4

5

6

8

10

15

20

30

0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0

3

4

6

5

8

10

15

20

30

40

0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0

6

8

10

15

20

30

40

0.035 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6

6

8

10

15

20

30

40

50

0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6

1.5

2

3

4

6

8

10

15

20

6 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0 4.0

1.5

2

3

4

6

8

10

15

20

25

0.04 0.05 0.06 0.08 0.1 0.15 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 4.03.00.2

30

20

15

10

8

6

5

4

30.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4

30

20

15

10

8

6

5

4

30.06 0.08 0.1 0.15 0.2 0.3 0.4

50Hz

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

60Hz

Value in the chart shows the suction bore and Motor output: kW of pump

( )Value in the chart shows the suction bore and Motor output: kW of pump

φ32 0.75kW

φ32 0.4kW

φ40 0.75kW

φ40 1.5kW

φ50 1.5kW

φ65 2.2kW

φ502.2kW

φ32 0.75kW

φ32 0.4kW

φ32 1.5kW

φ40 0.75kW

φ40 1.5kW

φ40 2.2kW

φ50 1.5kW

φ65 2.2kW

φ503.7kW

φ502.2kW

φ653.7kW

1.5kW

φ40·φ50 0.75kW

0.4kW

2.2kW

3.7kW

φ40 0.4kW

φ50 1.5kW

φ50 2.2kW

φ80 5.5kW

φ80 3.7kW

φ80 2.2kW

φ50 0.75kW

φ25 0.21kW

φ32 0.21kW

φ40 0.4kW

φ651.5kW

φ802.2kW

φ1003.7kW

φ125 5.5kW φ150

7.5kW

φ40 0.75kW

φ50 1.5kW

φ25 0.21kW

φ32 0.4kW

φ65 1.5kW

φ80 2.2kW

φ80 3.7kW

φ100 5.5kW

φ125 7.5kW

φ150 11kW

φ652.2kW

φ1003.7kWφ50

0.75kW

φ40 0.75kW

φ50 0.75kW

φ40 0.4kW

φ50 1.5kW

φ40 0.75kW

φ50 0.75kW

φ40 0.4kW

φ50 1.5kW

Self-priming

Self-priming

Nyloncoating

Self-priming Resin Nylon

coatingSea

water

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)To

tal h

ead

(m)

GSN(2)-C type■ Features

■ Selection chart

■ Selection chart

■ Standard specifications

■ Standard specifications

■ Standard specifications

GSP type KAWA HOPE

■ Features● Improved strength by using chemical resin

material. Outdoor use allowed.● Using stainless steel for metal material such

as the shaft, which prevents corrosion and rust.

● Fast self priming and outstanding suction properties.

● Easy maintenance attributed by simple structure and semi-open impeller

● Flanged the discharging side connection part.

■ Standard specifications

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

FS(4)type Sel-super

■ Features● Over the years actual achievement as a self-priming● Self-priming pump construction does not require foot valve and makes

priming works easier● Mechanical seal types are also available (bore size: 50~100mm)● Easy maintenance and inspection due to back pull out construction

Self-priming

GSO -C type23

■ Features● Superior suction performance make it possible to

pump up even from deep wells● Strong and durable construction against sand by

adopting special kind mechanical seal● The protection switch (manual return) provides

safety.● A semi-open type impeller is resistant to foreign

objects such as sand. A Back Pull Out structure is incorporated.

(*1) Discharge performance may drop when pump operate under negative suction total head.(*2) 0.75kW or more is equipped with a Premium efficiency motor.

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

( )Value in the chart shows the suction bore and Motor output: kW of pump■ Selection chart

( )Value in the chart shows the suction bore and Motor output: kW of pump■ Selection chart

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

● Preventing red discolorment of water by exclusively design as nylon coating

● Adoption of low noise type TEFC motor● Self-priming pump construction does not require

foot valve and makes priming works easier● Easy maintenance and inspection due to back pull

out construction

φ40·φ50 0.75kW

φ50

φ40

φ80

φ80

3 4

Page 4: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Centrifugal / Multistage pump series

GE-2M type

Stainless steel

GES-C typeBore : 40~65mmMotor : 0.75~7.5kW (50Hz) 1.5~7.5kW (60Hz)

Sister models

Liquid Clean water 0~90˚C (no freezing)

Suction total head (20°C)-6m (60Hz Bore size 50mm 0.75kW : -3.2m, bore size 80mm 5.5, 7.5kW : -5.5m

MaterialsImpeller Cast iron or BronzeShaft SUS304

Cast ironCasingTEFC outdoorTypeThree phasePhase

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

Premium efficiency (IE3)EfficiencyInstallation Indoor

Self-priming

* KVS-HM : for high pressure

Clean water 0~90˚C (no freezing)Bore 25~50mm/-6mBore 65mm/-5mBore 80mm·100mm (5.5kW·50Hz) /-4mBore 80mm·100mm (7.5~22kW·50Hz) /-5mBore 80mm·100mm (60Hz) /-3mSCS13 or SUS304SUS316SCS13Mechanical seal (SiC x Carbon)TEFC outdoor (11~37kW : indoor)Three phase50Hz : 3,000min-1

60Hz : 3,600min-1

Premium efficiency (IE3)JIS 20K equivalentIndoor/outdoor (11~37kW : indoor)

ImpellerShaftCasing

TypePhase

Speed

Efficiency

Liquid

Suction total head (20˚C)

Materials

Shaft sealing

FlangeInstallation

Liquid Clean water 0~90˚C (no freezing)Suction total head (20˚C) within -6m (it may differ depending of model inquire.)

MaterialsCast iron or BronzeImpeller

Shaft SUS403 (portion contacting liquid)Casing Cast iron

Motor

Type TEFC indoorPhase Three phase

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

Efficiency Premium efficiency (IE3)*Installation Indoor

* 0.75kW or more is equipped with a Premium efficiency motor.● GE-4M (4 poles motor) type are also available. Inquire for further information.

KR -C type

Liquid Suction total head (20˚C)

Materials

Companion flanges

* Three phase 0.75kW or more is equipped with a Premium efficiency motor.

ImpellerShaftCasingShaft sealingTypePhase

Speed

Efficiency

Clean water 0~40˚C (no freezing)

-6mResin or SCS13 or BronzeSUS304 (portion contacting liquid)SCS13Mechanical seal (Ceramic x Carbon)TEFC indoorThree phase

50Hz : 3,000min-1

60Hz : 3,600min-1

Premium efficiency (IE3)*Special flange

Stainless steel

KR5-M typeBore : 40~65mmMotor : 1.5~7.5kW

Sister models

Motor

Motor

Motor

0.04 0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5

706050

40

20

30

15

10

8

6

0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0

80706050

40

30

20

15

10

8

65

4

10

15

20

30

40

5060

80

100110

3

4

56

8

0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.50.6 0.81.0 1.5 2.0 3.0

110100

80

6050

40

30

20

15

10

8

65

4

30.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0 4.0

6

8

10

15

20

30

40

50

60

80

100

0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8

0.040.03 0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0

3

4

56

8

10

20

15

30

40

5060

80

100

50.060.050.040.030.02 0.07 0.08 0.09 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.01.5

10

15

20

30

40

50

60708090

100

150170

200220240

50Hz

60Hz

50Hz

60Hz

3.7kW

2.2kW

1.5kW

0.75kW

3.7kW

7.5kW

1.5kW

0.75kW

7.5kW

5.5kW

3.7kW

2.2kW

5.5kW

2.2kW

5.5kW

3.7kW

2.2kW

7.5kW

5.5kW

3.7kW

2.2kW

1.5kW

3.7kW

5.5kW

7.5kW

1.5kW

0.75kW

1.5kW

0.75kW

Bore (mm) 40

Bore (mm) 40

Bore (mm) 50

Bore (mm) 65 Bore (mm) 80

Bore (mm) 50 Bore (mm) 65Bore (mm) 80

60Hz

Bore (mm)25

Bore (mm)32

Bore (mm)40

Bore (mm)50

Bore (mm)65

Bore (mm)80/100

1.5kW

0.75kW

0.75kW

11kW 18.5kW

1.5kW

1.5kW

2.2kW2.2kW

2.2kW

2.2kW3.7kW

3.7kW

3.7kW

3.7kW

3.7kW

5.5kW

5.5kW

5.5kW

5.5kW

5.5kW

7.5kW

7.5kW

7.5kW

18.5kW

18.5kW7.5kW

7.5kW

11kW

11kW

11kW

15kW

15kW

15kW 22kW

22kW

30kW

37kW

30kW

Bore (mm)40×32

Bore (mm)50×40

Bore (mm)65×50

Bore (mm)80×65

Bore (mm)100×80

1.5kW

1.5kW

1.5kW

0.4kW

0.4kW

2.2kW

2.2kW

2.2kW

2.2kW3.7kW

3.7kW

3.7kW

3.7kW5.5kW

5.5kW

5.5kW 7.5kW

7.5kW

7.5kW

11kW

11kW

11kW

15kW

15kW

15kW

22kW

22kW

37kW

45kW

30kW18.5kW

18.5kW

0.75kW

0.75kW

0.75kW

Bore (mm)40×32

Bore (mm)50×40

Bore (mm)65×50 Bore (mm)

80×65

Bore (mm)100×80

1.5kW

1.5kW

1.5kW0.4kW

2.2kW

2.2kW

2.2kW

3.7kW

5.5kW

3.7kW

3.7kW

3.7kW

5.5kW

5.5kW

5.5kW

7.5kW

7.5kW

7.5kW

11kW

11kW

11kW

11kW

15kW

15kW

15kW

22kW

22kW

30kW 45kW37kW

30kW18.5kW

18.5kW

18.5kW

0.75kW

0.75kW

0.75kW

1.1kW

1.5kW

2.2kW

3.7kW

5.5kW

1.5kW

2.2kW

3.7kW

5.5kW

3.7kW

5.5kW

7.5kW

50Hz

*1: Single phase100V*2: Single phase200V

60Hz

0.4kW *1

0.75kW *2

0.75kW

1.1kW

1.5kW 2.2kW

3.7kW

5.5kW

1.5kW

2.2kW

7.5kW

5.5kW

3.7kW

3.7kW

5.5kW

7.5kW

7.5kW

KVS-HMtype

StainlesssteelStainless

steel

GE-C type

KVS type

( )Value in the chart shows the suction bore and Motor output: kW of pump■ Selection chart

( )Value in the chart shows the suction bore and Motor output: kW of pump■ Selection chart

45

5 6

Bore (mm) 32Bore (mm) 40

Bore (mm) 40Bore (mm) 50

Bore (mm) 65

Bore (mm) 50

Bore (mm) 65

2.2kW

5.5kW■ Features● Compact, light weight and less installation space by adoption of 2 pole

electric motor● Long life mechanical seal is adopted for shaft sealing● Easy maintenance and inspection without dismantle of piping due to

back pull out construction and simple structure● Evaluated item of <Horizontal centrifugal pump> by (C) Public

Buildings Association., Ltd. (Japan)

■ Standard specifications

■ Standard specifications

■ Features● Compact, light and space saving design● Adoption of Stainless steel precision casting for

Casing, stage casing, etc.● Mechanical seal can be changed without removing

electric motor due to outstanding construction feature (unit type mechanical seal cover with mechanical seal support and spacer shaft coupling) (5.5kW or more)

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

■ Selection chart( )Value in the chart shows the suction bore and Motor output: kW of pump

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

■ Selection chart( )Value in the chart shows the suction bore and Motor output: kW of pump

Tota

l hea

d (m

)

Capacity (m3/min)

Tota

l hea

d (m

)

Capacity (m3/min)

■ Features

■ Standard specifications

■ Standard specifications

● Compact, light weight and less installation space by adoption of 2 pole electric motor

● Other than standard model (GE-2M type) , Nylon coating type (GEN-2M type) is also available

● Long life mechanical seal is adopted for shaft sealing● Easy maintenance and inspection without dismantle of piping due to

back pull out construction and simple structure

■ Features● Stainless steel precision casting● Quiet sound design of pump and

electric motor enable pump unit operation with lower noise

● Easy maintenance and inspection due to back pull out constructionTo

tal h

ead

(m)

Capacity (m3/min)

KVS-HMtype

0.060.050.030.02 0.04 0.07 0.08 0.09 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.01.5

10

5

15

20

30

40

50

60708090

100

150170

200220240260

280

0.060.050.030.02 0.04 0.07 0.08 0.09 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.01.5

10

5

15

20

30

40

50

60708090

100

150170

200220240260

280

50Hz

2.2kW

1.5kW

0.75kW

2.2kW

3.7kW

3.7kW

2.2kW

3.7kW

5.5kW

7.5kW

2.2kW

3.7kW

5.5kW

7.5kW

11kW

15kW

18.5kW22kW

37kW

30kW

5.5kW

7.5kW

11kW

15kW

18.5kW

22kW

30kW

1.5kW

2.2kW

5.5kW

Bore (mm)25

Bore (mm)32

Bore (mm)40

Bore (mm)50

Bore (mm)65

Bore (mm)80/100

11kW

1.5kW

0.75kW

11kW3.7kW 5.5kW

7.5kW15kW

Page 5: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

■ Selection chart

Self-priming

Self-priming

Centrifugal / Multistage pump series

LiquidClean water 0~90℃ (no freezing) (Maximum 100℃:Please inquire)

Suction total head(20℃)

Bore 20~65mm -6mBore 80mm -5.5(-3m for 60Hz)

Impeller SCS13Materials Shaft SUS304(portion contacting liquid)

Casing Cast ironShaft sealing Mechanical seal

Type TEFC outdoor

PhaseSingle phase

MotorSpeed

Three phase 50Hz:3,000min-1

60Hz:3,600min-1

Efficiency Premium efficiency(IE3)*Installation Indoor/Outdoor* Three phase 0.75kW or more is equipped with a Premium efficiency motor.Note) Apply for anti-freezer within following specification.

・Kind: Nybrine Z-1, GD brine 950 and Showbrine PP super・Density: 35~50%・Liquid temperature: 0~90℃

Stainless steel

GES-2M typeBore :40~65mmMotor:0.75~7.5kW

Sister models

ImpellerShaftCasing

TypePhase

Speed

Efficiency

Clean water 0~90℃ (no freezing)-6mSCS14SUS316 (portion contacting liquid)SCS13Mechanical seal (SiC x Carbon)TEFC inoorThree phase50Hz:1,500min-1

60Hz:1,800min-1

Premium efficiency (IE3)*2

(*1) Inquire for special kind liquid use.(*2) 0.75kW or more is equipped with a Premium efficiency motor.

40

6

4

8

10

15

20

30

0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0

6

5

8

10

15

20

30

40

50

0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0

50

40

30

20

15

10

8

65

4

3

20.02 0.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.6 0.8 1.0 1.5 2.0

60

50

40

30

20

15

10

8

6

5

4

30.02 0.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.60.5 0.8 1.0 1.5 2.0

φ40 0.4kW

φ40 0.75kW

φ50 1.5kW

φ50 2.2kW

φ50 0.75kW

φ65 1.5kW

φ65 2.2kW

φ65 3.7kW

φ80 2.2kW

φ80 5.5kW

φ80 7.5kW

φ100 5.5kW

φ100 3.7kW

φ100 7.5kW

φ10011kW

φ10015kW

φ40 0.75kW

φ40 1.5kW

φ50 1.5kW

φ50 2.2kW

φ50 3.7kW

φ65 2.2kW

φ65 3.7kW

φ65 5.5kW

φ80 3.7kW

φ80 5.5kW

φ80 11kW

φ100 5.5kW

φ100 3.7kW

φ100 7.5kW

φ100 11kW

φ100 18kW

φ20 0.1kW

φ32 0.4kW

φ40 1.5kW

φ50 3.7kW

φ65 3.7kW

φ80 5.5kW

φ80 7.5kW

φ80 3.7kW

φ80 2.2kW

φ65 1.5kW

φ65 2.2kW

φ50 2.2kW

φ80 1.5kW

φ32 1.5kW

φ320.75kW

φ40 0.4kW

φ20 0.15kW

φ25 0.15kW

φ20 0.25kW

φ25 0.25kW

φ32 0.25kW

φ50 0.75kW

φ65 0.75kW

φ40 0.75kW

φ250.4kW

φ40 3.7kW

φ40 2.2kW

φ50 1.5kW

φ200.1kW

φ250.1kW

φ32

φ250.15kW

0.15kW

φ200.15kW

φ250.25kW

φ250.4kW

0.25kWφ32

0.25kWφ40

0.75kWφ32

0.4kWφ32

0.4kWφ40

0.4kWφ50

1.5kWφ40

1.5kWφ50

0.75kWφ40

0.75kWφ50

2.2kW

3.7kW

2.2kW

φ40

2.2kWφ50

3.7kWφ50

φ65

φ65

1.5kWφ65

0.75kWφ65 1.5kW

φ802.2kW

3.7kWφ80

φ80

7.5kWφ80

5.5kWφ80

φ803.7kW

φ80 7.5kW

φ100 15kW

φ100 22kW

( )Value in the chart shows the suction bore and Motor output: kW of pump ( )Value in the chart shows the suction

bore and Motor output: kW of pump

● Sanitary and clean due to stainless material are used for all portions contacting liquid

● Mechanical seal standard adopted.● TEFC electric motor as standard● High pump efficiency and water

pumping characteristics.

Liquid*1

Suction total head (20℃)

Materials

Shaft sealing

Motor

■ Features

■ Standard specifications

■ Features

■ Standard specifications

50Hz

60Hz

PE(2)type P in Line pump50Hz

60Hz

type

GES-4M type type

Stainless steel

■ Selection chart

Capacity (m3/min)

Capacity (m3/min)

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)To

tal h

ead

(m)

Capacity (m3/min)

Capacity (m3/min)

● Single phase motor is equipped with a motor protective device which prevent motor burnout. (250W or less)

● All model adopts totally-closed motor. The quiet design enables a low level noise as an open motor.

● The newly-developed high class mechanical seal prevents mechanical chatter. This seal prevents leak and extends the products life.

Petit Line

T type

TN typeBore :40~150mmOutput:1.5~75kW

TVS typeBore :40~150mmOutput:1.5~75kW

KS typeBore :40~80mmOutput:2.2~22kW

Turbine pump (Multi-stage pump) Stainless steel

Self-priming turbine pump

■ Features

T(N)・TK(N) type

TVS type・KS type

T(N) · TK(N) type● Less installation space according to simple and compact pump

construction with light weight● Other than standard model (T/TK), Nylon coating type (TN/TKN)

is also available● Evaluated item of <Horizontal centrifugal pump> by (C) Public

Buildings Association., Ltd. (Japan) (T/TK type)

TVS type, KS type● Self-priming pump construction does not require foot valve and

makes priming works easier● Various kind of models for small to large flow rate

Bore :40~200mmOutput:1.5~132kW PSS(2) type

Large water type

Vertical type Centrifugal Pump

FV(D) - type

PSS (2) type Petit Line Bore :20~80mmMotor :0.06~7.5kW

FV (D)- type Vertical type Centrifugal PumpBore :100mm(2 Pole)~200mm(4 Pole)Motor :7.5~90kW

c4c

7 8

C4C

Page 6: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Self-priming

Self-priming

Self-priming

40

5060

80

100120

30

15

20

8

10

65410 15 20 30 40 50 60 80 100 150 200 300

40

30

20

15

10

8

6

45

100

150

80

6050

10 2015 30 40 50 60 80 100 150 200 300

φ320.4kW

φ501.5kW

φ250.2kW

φ401.5kW

φ652.2kW

φ200.13kW

φ322.2kW

φ251.5kW

φ403.7kW

φ252.2kW

φ323.7kW

φ405.5kW

φ403.7kW

φ320.75kW

φ200.1kW

φ200.13kW

φ250.2kW

φ400.75kW

φ652.2kW

φ320.75kW

φ320.4kW

φ400.75kW

φ501.5kW

φ502.2kW

φ200.1kW

45

3 4

6

810

15

20

30

405060

80100

150

5 6 8 10 15 20 30 40 50 60 80 100 150 200

150

10080

605040

30

20

15

10

8

654

3 4 5 6 8 10 15 20 30 40 50 60 80 100 150 200

50Hz

φ200.2kW

φ250.4kW

φ320.75kW

φ401.5kW

φ403.7kW

φ501.5kW

φ322.2kW

60Hz

φ200.2kW

φ405.5kW

φ250.4kW

φ320.75kW

φ401.5kW

φ251.5kW

φ400.75kW

φ320.4kWφ25

0.2kW

φ323.7kW

φ403.7kW

φ252.2kW

φ502.2kW

φ501.5kWφ40

0.75kWφ320.4kW

φ250.2kW

Cascade pump series Submersible clean water pump series

Oil pump series

 Minimum well diameter 100mm(Value in the chart shows the suction bore and Motor output: kW of pump)

Minimum well diameter 150mm

Clean water 0~30℃ (3.7kW or less: 0~35℃)(pH5.8~8.6,Chloride ion concentration 200mg/L or less,Sand content 50mg/L or less (fine sand dia. 0.1~0.25mm or less))

Liquid

Materials

Impeller SCS13Shaft SUS304 or SUS403

Casing SCS13 (32 and 25mm bores are middle casingSUS304 + resin)

Bearing SiC×SiC

Motor

TypePhase Three phase (55kW : 400V)

Canned submersible motor

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

Liquid

Materials

Shaft sealing

Motor

ImpellerShaftCasing

TypePhase

Speed

Kerosene, light oil, A type heavy oil (*)Fuel oil of 45 centistokes or less60℃ or lessBronzeSUS403Cast ironMechanical sealIncreased safety explosion-proof type (Japan)Three phase50Hz : 1,500min-1 60Hz : 1,800min-1 (OC(K) type)50Hz : 3,000min-1 60Hz : 3,600min-1 (OCH type)

OC(K)type

OCH type

* Use the OCK type for special A type heavy oil.

*400V type is also available

CHS typeBore :25~40mmMotor:1.5~5.5kW

CS2 typeBore :20~50mmMotor:0.2~2.2kW

CS3 type (Only 60Hz)Bore :20~25mmMotor:0.2~0.4kW

Sister models

LiquidSuction total head (20℃)

MaterialsImpellerShaftCasingTypePhase

Speed

Clean water 0~40℃ (no freezing)-7m(Bore 20, 32 : -8m)BronzeSUS304 or SUS403 (portion contacting liquid)Cast ironODP or TEFCThree phase50Hz : 3,000min-1

60Hz : 3,600min-1

Motor

8

10

5

4

6

20

30

40

50

60

80

100

200

0.06 0.08 0.10.020.015 0.03 0.04 0.05 0.15 0.2 0.3 0.4

8

10

20

30

40

50

60

80

100

200

300

0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.01.1

910

20

30

40

50

60

80

100

200

300

0.06 0.08 0.10.020.015 0.03 0.04 0.05 0.15 0.2 0.3 0.4

8

65

10

20

30

40

50

60

80

100

200

300

0.07 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0

0.75kW

0.75kW

1.1kW

1.1kW

1.5kW

1.9kW

1.9kW

3.7kW

2.7kW

2.2kW

1.5kW

3.7kW

2.7kW2.2kW

1.9kW1.5kW

1.1kW

2.2kW

Bore (mm)25・32

Bore (mm)40

Bore (mm)40

Bore (mm)50

Bore (mm)65

Bore (mm)80

Bore (mm)50

Bore (mm)25・32 Bore (mm)

40Bore (mm)

50

0.75kW

1.1kW

1.1kW

1.5kW

1.9kW

2.2kW

3.7kW

2.7kW

1.5kW

1.9kW

2.2kW

2.2kW

3.7kW

3.7kW

2.7kW

2.7kW

1.9kW

1.5kW

1.9kW

1.9kW

2.2kW

2.2kW

2.7kW

2.7kW

3.7kW

3.7kW

3.7kW

2.7kW

5.5kW

5.5kW

5.5kW

5.5kW

11kW

11kW

11kW

15kW

15kW

15kW

22kW

18.5kW 5.5kW

7.5kW

7.5kW

7.5kW

7.5kW

7.5kW

11kW

15kW

11kW

1.1kW

1.5kW2.2kW

3.7kW

7.5kW

1.5kW

2.2kW

2.7kW

3.7kW

5.5kW

7.5kW22kW

18.5kW

7.5kW

7.5kW

7.5kW

15kW

15kW11kW

18.5kW

5.5kW

5.5kW

5.5kW

3.7kW

3.7kW

2.7kW

2.7kW

2.2kW

11kW

11kW

11kW

2.2kW

1.1kW

1.5kW

3.7kW

( )Value in the chart shows the suction bore and Motor output: kW of pump

( )Value in the chart shows the suction bore and Motor output: kW of pump

Self priming

OC(K)・OCH type

■ Selection chart

■ Standard specifications

Self priming

■ Standard specifications

■ Selection chart

Stainless steel

50Hz 60Hz

50Hz 60Hz

■ Standard specifications

■ Selection chart

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)To

tal h

ead

(m)

Capacity (m3/min) Capacity (m3/min)

Capacity (m3/min) Capacity (m3/min)

Bore (mm)40

Bore (mm)50

Bore (mm)65

Bore (mm)80

CS(2)-C type US2 type SANRONG

● Self-priming pump construction does not require foot valve and makes priming works easier

● Long-life product with high suction performance and durability

● Easy maintenance due to adoption of sealed ball bearings required no oiling.

● Equipped with a motor protective switch which prevent motor burnout.

■ Features

● The vortex pump enables quiet operation. (Unlike the gear pump, there is no gear contact section)

● Since it is a self priming type, it operates with priming the oil once, and easy to pump oil.

● Mechanical seal is used for the shaft sealing ,which prevents oil leak and keeps clean.

● Increased safety explosion-proof type is adopted as standard.

● Conformed to "Public building construction standard specification" by Public building association. (Japan)

● OC(K) type for A type heavy oil(high-calories special A type heavy oil) is also available.

● OC-TT type, a service tank installed unit, is also available.

■ Features

● The pump section is resistant to sand, and in addition a thick precision casting stainless steel is incorporated.More strong to sand and reliable by a new-type motor excellent in durability and bearing lubrication.

● The pump is stainless steel and resin. The motor section is made of stainless steel and prevents the formation of red water. The well lid is also made of stainless steel for sanitation purposes.

● The pump's flow passage is smooth and has little loss. High pump characteristics are realized, and the pump's entire length is downsized (compared to conventional products).

● The key components are made of precision cast stainless and steel, and are strong against rust and corrosion. When used in combination with the new stainless steel motor having outstanding sand resistance properties, water can be supplied stably for a long time.

■ Features

Do not use with the head (m) out of specified point.Could cause the motor burn out.

Tota

l hea

d (m

)To

tal h

ead

(m)

CHS

CHS

50Hz

60Hz

Capacity (m3/min)

Capacity (m3/min)

Tota

l hea

d (m

)To

tal h

ead

(m)

Capacity (m3/min)

Capacity (m3/min)

Do not use with the head (m) out of specified point.Could cause the motor burn out.

* For 200/250/300mm well types are also available. Inquire for further information.* If installed in a well larger than the well diameter of the specification table, the submerged motor may burn out due to insufficient cooling of

submerged motor.Installed in the cooling flow rate to be 0.075m/s or more for motor output less than 3.7 kW and 0.1m/s or more for motor output more than 5.5 kW. 9 10

Page 7: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Self-priming

Self-priming

Self-priming

Submersible clean water pump series Submersible Sump Pump Series

Sister models

exclusive for horizontal installation

KUR3-YtypeBore :32~65mmMotor:0.75~3.7kW

Sister models

Impeller SCS13 or BronzeShaft SUS403 or SUS303Casing SCS13(Suction casing SUS304)Type Canned submersible motorPhase Three phase

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

10m

Liquid For Sewage (pH:5~9) 0~40˚C

MaterialsImpeller ResinShaft SUS304 (portion contacting liquid)Casing ResinType Dry-sealed motor

PhaseSingle phase

Motor Three phase

Speed50Hz:3,000min-1

60Hz:3,600min-1

Max. submersing depth 5m (1.5kW or more:8m)

* Foreign matter refers to free deforming soft matter excluding sand, etc. as defined in JISB8325.

USM type USMH type

USMtype

USMHtype

For Wastewater

WUP3-G type KAWA PETBore :32~50mmMotor:0.15~0.75kW

Sister modelsTitanium seawater submersible pump

WUZ -G type KAWA HOPEBore :32~80mmMotor:0.15~3.7kW

AU4 typeBore :50~100mmOutput:0.75~7.5kW

BU4 type BUW type (pedestal support type)

Bore :50~150mmOutput:0.75~22kW

Bore :65~80mmOutput:1.5~7.5kW

VU4 typeBore :50~100mmOutput:0.75~15kW

ZU3 typeBore :50~80mmOutput:0.4~7.5kW

For hot water / hot spring submersible pump

KURH typeBore :32~50mmMotor:1.9~7.5kWLiquid temperature: clean water 60˚C or less

23

Liquid

Simple thermal, sodium-chloride thread, sodium-hydrogen carbonate pH6 to 9(Sand content 50mg/L or less (fine sand dia. 0.1~0.25 mm or less))

Materi-als

Impeller SCS13Shaft SUS304 or SUS403Casing SCS13

Shaft sealing SiC×SiCType Canned submersible motorPhase Three phase

Speed50Hz : 3,000min-1

60Hz : 3,600min-1

Max. submersing depth

USM : within 150 mUSMH : within 350 m

23

Motor

0.015 0.02 0.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.810

15

20

30

40

5060

80

100

150

200

300

70

80

90

60

50

40

30252010

100110

130

150

200

250

400300

0.060.020.01 0.07 0.08 0.09 0.1 0.13 0.15 0.2 0.25 0.40.3 0.5 0.6 0.7 0.90

0.015 0.02 0.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.810

15

20

30

40

5060

80

100

150

200

300

0.060.020.01 0.07 0.08 0.09 0.1 0.11 0.12 0.13 0.15 0.2 0.25 0.40.3 0.5 0.6 0.7 0.9

70

80

90

60

50

40

30

252010

100110

130

150

200

250

400300

200

150

100

80

6050

40

30

20

15

10

8

6

4

20.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 2.0 3.0 4.01.5

200

150

100

80

6050

40

30

20

15

10

8

65

4

30.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 3.02.0 4.0

1.5

2

3

4

56

8

10

15

20

30

0.015 0.02 0.03 0.04 0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0

1.5

2

3

4

56

8

10

15

20

30

0.015 0.02 0.03 0.04 0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0

7.5kW

1.9kW

1.5kW

1.5kW

2.2kW

3.7kW

3.7kW

7.5kW

7.5kW

7.5kW

11kW

5.5kW

5.5kW

5.5kW

3.7kW

3.7kW

2.2kW

2.2kW

Bore(mm)32

Bore(mm)32

Bore(mm)32

Bore(mm)40

Bore(mm)50

Bore(mm)65

Bore(mm)40

Bore(mm)40

Bore(mm)40

Bore(mm)50

Bore(mm)50

Bore(mm)50

Bore(mm)65

Bore(mm)65

Bore(mm)65

2.7kW

1.9kW

2.7kW

3.7kW

2.7kW

2.7kW

5.5kW

5.5kW

7.5kW

11kW

15kW

22kW

Bore (mm)32

Bore (mm)40

Bore (mm)50

Bore (mm)100

Bore (mm)65

Bore (mm)80

505 -0.75505/655 -1.5

655 / 805 -3.7

655 /805 -2.2

505 -0.4

405 -0.25

405 -0.15S

506 -0.75 506 / 656 -1.5

656 / 806 -3.7656/806

-2.2

506 -0.4

406 -0.25

406 -0.15S

TS

TS

TS

TS

3.7kW

3.7kW

1.9kW

5.5kW

1.9kW1.5kW

1.5kW

2.2kW

2.2kW

2.2kW

3.7kW

3.7kW

3.7kW

3.7kW5.5kW

5.5kW

5.5kW

7.5kW

7.5kW

7.5kW

3.7kW11kW

11kW

11kW

22kW18.5kW

15kW

15kW

15kW

5.5kW

7.5kW

2.7kW

2.7kW

3.7kW

3.7kW

11kW

7.5kW

0.75kW 0.75kW

0.75kW

1.5kW1.5kW

1.5kW

1.5kW

2.2kW

2.2kW

2.2kW

3.7kW

3.7kW

3.7kW

3.7kW

3.7kW

5.5kW

5.5kW

5.5kW

7.5kW

18.5kW

18.5kW

7.5kW11kW

37kW

22kW

15kW

11kW

11kW

30kW

45kW

5.5kW

7.5kW

0.75kW

0.75kW

1.5kW

1.5kW

1.5kW

1.5kW

2.2kW2.2kW

2.2kW

2.2kW

2.2kW

3.7kW 7.5kW

7.5kW

5.5kW

7.5kW

3.7kW

3.7kW5.5kW

3.7kW

3.7kW

0.75kW

5.5kW

7.5kW 11kW 15kW

11kW

11kW

15kW30kW

15kW

22kW

37kW

45kW

18.5kW

11kW

15kW7.5kW

15kW

11kW

7.5kW

22kW11kW

11kW

11kW

18.5kW

15kW

11kW

22kW

Bore(mm)32

( )Value in the chart shows the suction bore and Motor output: kW of pump

( )Value in the chart shows the suction bore and Motor output: kW of pump

( )Value in the chart shows the suction bore and Motor output: kW of pump

■ Standard specifications

Stainless steel

Stainless steel

60Hz

50Hz

60Hz

50Hz

■ Selection chart

50Hz

60Hz

Vortex with cutter

Stainless Non-clog impeller

Sewage water submersible pump

Sewage water submersible pump

Sewage water submersible pump

■ Selection chart

■ Standard specifications

■ Ability to pass foreign objects

■ Selection chart

Resin

50Hz

60Hz

BU4 type

BUW type

VU4 type

ZU type3J

AU4 typeCHAMPION

KUR type23

USM(H) type WUO(3)-G typeKAWA PET

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)To

tal h

ead

(m)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

Capacity (m3/min)

● This pump newly developed for spa use can be used with hot spa water up to 70˚C for USM type, up to 90˚C for USMH type (80˚C for some models).

● The key components are made of precision cast stainless steel (SCS13) and have a long life.

● SiC is used for the bearings to enhance the sand resistant design.

■ Features

Tota

l hea

d (m

)To

tal h

ead

(m)

Clean water 0~30˚C (0.75~2.2kW: 0~35˚C)(chloride ion concentration : 200mg/L or less,sand content 50mg/L or less)

● Red water prevention structure mainly made of stainless steel, and resin and rubber.

● The pump casing and flanges are made from precision cast stainless steel to withstand heavy load and free from strain.

● Built in impact relief type check valve to protect the pump from water hammer thus long life is enjoyed.

■ Features

● Vortex type and excellentperformance to pass foreign objects.

● Light weight and easy-to-handle submersible sewage pump.

● Stainless steel made frame motor and plastic parts increase operating life.

● Uses glass fiber reinforced plastic for the impeller and casing, and equipped with a motor with built-in auto-cut having a large starting torque for stable operation.

● Can be paired with plastic pedestal support (special accessory).

■ Features

● Dia. of foreign object (sphere shape) : 35mm (2.2kW or more: 40mm)

Bore (mm)32

Bore (mm)40 Bore (mm)

50

Bore (mm)100Bore (mm)

65

Bore (mm)80Liquid

Materials

Motor

Max. submersing depth

■ Standard specifications

11 12

* If installed in a well larger than the well diameter of the specification table, the submerged motor may burn out due to insufficient cooling of submerged motor.Installed in the cooling flow rate to be 0.1m/s or more.

* Accessories to prevent the occurrence of gas lock is also available (USMH-G type).

Please inquire for details.

Page 8: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Self-priming

Fire fighting pump series Energy-saving inverter

KFE-A・P typeAlternate/Paralleloperation

KF2-R typeMAX. 6 pumps rotaryoperation

KF2-HR typeHigh pump head type

KFE-T type3 pumps rotary operation

Vertical type for high head Rotary operation.KVF-G type

Sister models

(*1) Please consult in case back pressure exceed 5m or more.(*2) Suction actual head within -4m, 11 or 15kW model:suction total head within -4m

BronzeSUS304 or SUS420J2QCast ironTEFC indoor (5.5, 7.5 kW model : outdoor)Three phase/2 pole

ImpellerShaftCasingTypePhase/Poles

BronzeSUS403Cast ironTEFC indoorThree phase/4 pole

ImpellerShaftCasingTypePhase/Poles

SCS13 (80φ:Bronze)SUS403Suction:SUS304 Discharge:SCS13Canned submersible motorThree phase/2 pole

ImpellerShaftCasingTypePhase/Poles

BronzeSUS420J2 or SUS403Cast iron・Ductile cast iron (KTGDF)TEFC indoorThree phase/4 pole

ImpellerShaftCasingTypePhase/Poles

6025

30

40

50

60

80

100

120

80 100 150 200 300 400 500 600 800 1000 1200

φ40 2.2kW

φ50 3.7kW

φ65 5.5kW

φ65 7.5kW

φ65 11kW

φ80 11kW

φ80 15kW

φ80 18.5kW

φ50 5.5kW

φ50 7.5kW

φ40 3.7kW

φ40 5.5kW

φ50 11kW

Note: Suction bore 80mm model is different form the pump bore because a reducer is attached.(Units without pump priming tanks are excluded)

6025

30

40

50

60

80

100

120

80 100 150 200 300 400 500 600 800 1000 1200

φ40 2.2kW

φ50 3.7kW

φ65 5.5kW

φ65 7.5kW

φ65 11kW

φ80 11kW

φ80 15kW

φ80 18.5kW

φ50 5.5kW

φ50 7.5kW

φ40 3.7kW

φ40 5.5kW

φ50 11kW

KTK-C type

KTK-C type2 pole Compact

KTGF・KTGDF type4 pole Centrifugal / High back pressure type

KTY type4 pole centrifugal pump

KTK-W typeKTY-W typeCubicle type

KTY-ET typeEquipped with emergency power source (with engine)

KTU(2)type2 pole submersible turbine

Products qualified by the Fire Equipment and Safety Center of Japan

200

100

150

9080

70

60

50

40

30

20

10.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4 5

KF2-HRtype

KF -P/TtypeKF -Ttype KF2-Rtype

(3 to 6 units)

KF -AtypeE2

E2

E2

■ Selection chart

■ Standard specifications

■ Standard specifications

■ Standard specifications

■ Standard specifications

60Hz

50Hz50Hz・60Hz

SAFETY ACE® Series

Stainless steel

KF type

KFE-A・P・T type Alternate, alternate/parallel, 3-unit rotary

KF2-A・P・T・R type Rotary operation

Control method

Operation methodLiquidSuction condition

pumpImpellerShaftCasing

Type

PhaseEfficiency

Installation

Materials

Constant estimated terminal pressure by frequencycontrol (Discharge rate can also be controlled)Alternate, alternate/parallel, 3-unit rotaryClean water 0~40˚C (no freezing)0 to 5m of flow or up to -6 of suction total headStainless steel multi-stage turbine pumpResin or Stainless steelSUS304 (portion contacting liquid)SCS13TEFC indoorPoles:4 or 8 (max. speed: 4,500min-1)Three phaseSuper premium efficiency (rank as IE5)Indoor (0~40˚C / humidity:90%RH or less / altitude:1,000m or less)

Control method

Operation methodLiquidSuction condition

pumpImpellerShaftCasing

Type

PhaseEfficiency

Installation* Three phase 0.75kW or more is equipped with a Premium efficiency motor.

Constant estimated terminal pressure by frequencycontrol (Discharge rate can also be controlled)Alternate, alternate/parallel, rotary unit (MAX. 6 units)Clean water 0~40˚C (no freezing)0 to 5 m of flow or within -6 m of suction total headStainless steel multi-stage turbine pumpResin or SCS13 or BronzeSUS304 (portion contacting liquid)SCS13TEFC indoorPoles:2 (Max. frequency in case automatic operation:60Hz)Three phasepremium efficiency (IE3)*Indoor (0~40˚C / humidity:90%RH or less / altitude:1,000m or less)

Control method

Operation methodLiquidSuction condition

pumpImpellerShaftCasing

Type

PhaseEfficiency

Installation

Constant estimated terminal pressure by frequencycontrol (Discharge rate can also be controlled)Alternate, alternate/parallel, rotary unit (MAX. 6 units)Clean water 0~40˚C (no freezing)0 to 5 m of flow (*1) or within -6 m of suction total head (*2)

Stainless steel multi-stage turbine pumpBronzeSUS304 (portion contacting liquid)SCS13TEFC indoor2 poleThree phasepremium efficiency (IE3)Indoor (0~40˚C / humidity:90%RH or less / altitude:1,000m or less)

Motor

Materials

Motor

Materials

Motor

■ Standard specifications

■ Standard specifications

■ Standard specifications

KF2-HR type Rotary operation

● By adopting a 50L pump priming tank/ 50L pressure tank and control panel adopting high functional microcomputer compatible to the new technological standard, the installation area is minimized.

● Standardizing full water/decreased water circuit in the pump priming tank/ fire tank/ supply tank. (Two level relays (a special accessory) are required in order to detect full water/decreased water in supply tanks.) Additionally, automatic inspection of the fire pump can be performed by simply installing the separately sold automatic inspection accessory.

● A pump priming tank is highly resistant to rust and scratches due to high-quality powder coating applied, without problems of holes forming after long term use. (Stainless steel materials models are also available Inquire)

● The pump priming tank provides an electrode type fluid level detection, enabling detection of full water/decreased water in the pump priming tank as a standard feature.

● A easy-to-read digital type ammeter/voltmeter is adopted for the pump performance inspection. Pressure and compound gauges with a large diameter of φ100 are equipped as a standard feature.

● All of the instruments can be inspected from a single side (panel side).

■ Features● By pump section's high efficiency design and IE5 equivalent PM motor, the KFE

type realized top class total efficiency in the industry.● By optimally controlling the pump speed according to the changes in working

water rate with the inverter, constant estimated terminal pressure water supply with little fluctuation at the water supply terminal is possible ,and maximum of 40% energy saving operation. (Kawamoto reducing valve type constant discharge rate water supply comparison)

● The pump casing and flanges are made from precision cast stainless steel to withstand heavy load and free from strain.The connection section is mainly made of stainless steel, and resin, and the Bronze components prevents the formation of red water.

● All models are equipped with a low-noise totally-enclosed motor as a standard. Highly Resistant to insulation deterioration due to dust and moisture and has a long machine life.

● The soft stop method is adopted for the inverter, eliminating the sound of the magnet tripping, and enabling quiet water supply.

● Each pump has a high power factor device with standard DC reactor, which helps energy saving and controls the generation of high harmonics.Countermeasures against noise are also provided with a surge absorber and noise filter.

■ FeaturesTo

tal h

ead

(m)

Tota

l hea

d (m

)

Capacity (L /min)

Tota

l hea

d (m

)

Capacity (L /min)

Capacity (m3/min)

Materials

Materials

Motor

Motor

Materials

Motor (continuous rating: S2)

Materials

Motor

KTK-C type Compact type

KTGF・KTGDF type

KTY type

KTU(2) type Submersible type

13 14Note) Please consult Kawamoto to use long-hours with small amount of water.

( )Value in the chart shows the suction bore and Motor output: kW of pump■ Selection chart

Page 9: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Self-priming

Self-priming

Self-priming

Self-priming

Self-priming

Energy-saving inverter Energy-saving inverter

LF/ LFE type Connection type pump selection chart

(Value in the chart shows the suction bore and Motor output: kW of pump)

Alternate operation80

70

60

50

40

30

20

15

12

32A2.2

32A1.5

40A1.5

40A3.7

50A5.5

50A2.2

65A7.5

40A2.250A3.7

65A3.7

65A5.5

0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0

Alternate / parallel operation

80

70

60

50

40

30

20

15

12

32P2.2

32P1.5

40P1.5

40P3.7

40P2.2

50P5.5

50P3.7

50P2.2

65P7.5

65P5.5

65P3.7

0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0

Control method Constant estimated terminal pressureOperation method Alternate/ParallelLiquid Clean water 0~40˚CPhase Three phase

Installation (unit part) Indoor (0~40˚C/humidity:90%RH or less/altitude:1,000m or less)

LFE type

USFE type

USF2 type・LF type

GS3-C type pump

US2 type pump

Control methodOperation method

Liquid

Phase

Installation (unit part)

Constant estimated terminal pressureIndividualUSFE, 2 type 0~35˚C, LF/LFE 0~40˚C(Refer to the fluid temperature of the connecting pump)Three phaseIndoor/Outdoor (0~40˚C/humidity: 90% RH orless/altitude:1,000m or less) *USF2/LF:Indoor

KR5-C type

KS type TVS type

89

10

15

20

30

40

50

60

70

8090

100

0.60.50.40.30.20.150.10.080.060.050.04

KStype

TVS type

*Use 60Hz products for pumps to connect to.

20

10

30

4050

70

100

150

200

0.01 0.02 0.03 0.05 0.2 0.3 0.40.08 0.1

φ32 1.1kW

φ40 1.1kW

φ32 1.5kW

φ32 2.2kW

φ32 2.7kW

φ40 2.2kW

φ40 2.7kW

φ50 2.2kW

φ50 2.7kW

Example for US(N)2 type (well diameter 100mm)

Example for US(N)2 type (well diameter 100mm / 150mm)

0.08 0.1 0.2 0.3 0.4 0.5 0.70.6

100

80

60

50

40

30

20

15

150USN2-40·50

0.07

φ50 5.5kW

φ40 3.7kW

φ40 3.7kW

φ40 5.5kW

φ50 3.7kW

φ65 3.7kW

φ65 5.5kW

φ50 7.5kW

φ65 7.5kW

φ50 3.7kW

Hot water pressurization pump unitNFH2 type150~750W

With signal output

NFS2 type

Sister models

 UF(L)2 type

1510505

10

20

30

40

50

20 30 40 50 60 80 100 150

450W

600W

900W1100W

 UF2 type

10010

20

30

40

50

60

708090

20 30 40 50 60 8070 90

450W

900W

1100W

600W

Shallow well● When operating as a single unit

(-8 m of suction head)● When operating alternately/in parallel

(-6 m of suction head)

● When operating as a single unit (-2 m of suction head)

● When operating alternately/in parallel(-2 m of suction head)

Control methodConstant discharge rate pressure water supply(constant estimated terminal pressure is possiblewith alternate, parallel/alternate models)

Operation method Single, Alternate, Alternate/ParallelLiquid Clean water 0~40℃(no freezing)Suction total head -8m(up to -6 in alternate, alternate/parallel models)to 5m flow in.

Materials

Pump Cascade pumpImpeller BronzeShaft SUS304 (portion contacting liquid)Casing SCS13

Motor Type Kawamoto PM motor (TEFC indoor) 4 polesInstallation Indoor/Outdoor (altitude:1,000m or less)

Control method Water supply with constant discharge pressureLiquid Clean water 0~25℃ (no freezing, sand content 50mg/L or less)

Materials

Impeller Resin+SUS304(UFL2 type:SCS13)Shaft SUS304

Casing Suction casing:SCS13, Discharge casing:SCS13, Stage casing:SUS304+Resin

MotorType Canned submersible motorPhase Three phase

Installation Indoor/Outdoor (pump:under water)

7060

50

40

30

20

10

5 4 10 20 30 40 50 60 70 80

300W

450W

*Please refer to KUR2 3 type (P.11) for pump material.

GS -C type3N

φ40 1.5kW

Alternate Alternate/Parallel

■ Features

■ Selection chart

■ Standard specifications

■ Features

■ Standard specifications

■ USFE type Connection type pump selection chart

■ USFE type Connection type pump selection chart

■ Features

■ Features

■ Selection chart

■ Standard specifications

■ Features

■ Standard specifications

For Surface pump*Applicable Pump GS3-C type · KR4

5 -C type · GE-C type · TVS type · KS type,etc.

For Deep well Submersible / Clean water submerged Pump※Applicable Pump US(N)2 type・KUR type

Stainless steel

60Hz

60Hz

Submersible clean water pump

Stainless steel

50Hz・60Hz 50Hz・60Hz

Pumper USF

Pumper LF

Pumper KUF type

KAWA ACE DEEPER

Stainless steel

UFE type

KAWA ACE DEEPER

Stainless steel

UF(L) 2type

For receiver tank

NF3 typeSoft KAWA ACE

Stainless steel

60Hz

● By optimally controlling the pump speed according to the changes in working water rate with the inverter, constant estimated terminal pressure water supply with little fluctuation at the water supply terminal is possible regardless of fluctuation in the well water level.

● The pump section and over ground automatic operation unit are both made mainly of stainless steel and resin and rubber. This enables clean water supply.

● The automatic operation unit has a compact design, smaller and lighter than the conventional pressure tank type enabling easy installation.

Capacity (m3/min) Capacity (m3/min)

Capacity (L/min)

Capacity (L/min)

Capacity (L/min)

Capacity (m3/min)

Capacity (m3/min)600W (UFH)

● Constant estimated terminal pressure water supply is possible by combining the stainless steel submerged turbine pump and inverter automatic operation unit.

● Clean water supply is ensured with mainly stainless steel units.● The installation space is small compared to the pressure tank method,

and installation work is easy.

● Switch between E (ecological) mode and S (Strong) mode is possible by the operation mode switch. (Exclude NFK2)

● Quiet, highly energy-saving operation is possible with the constant discharge rate pressure control by the inverter.

● Stainless steel and bronze materials are adopted for portion contacting water, thus preventing pump from rusting and red discolorment of water

● Noise and high frequency countermeasures are equipped as a standard with the noise filter and built-in reactor.

● Highly energy-saving water supply is possible with inverter control.● Surge resistance and noise resistance are improved by modifying the electric

parts assembly section and using a 4-core submerged cable.● Sanitary and clean due to stainless material are used for main parts of pump

and automatic operation unit.● The pump section is resistant to sand and has a long life by incorporating Sic

bearings, and rubber seal liner ring, etc.● Constant discharge rate water supply is possible without being affected by

fluctuations in the well water level. When installed in a shallow well, a regulator is not required.

● This economical pump has a capacity approximately double the capacity of a jet pump. ● The wet sections of the pump and automatic operation unit are made of rust resistant

stainless steel.● Precision cast stainless steel, thick stainless steel, wear resistance resin, rubber and Sic

bearings are incorporated in the pump which is strong against sand. ● The water pressure is maintained at a constant level by inverter control. 42 to 69% energy

saving can be anticipated compared to the non-inverter jet pump. (Kawamoto comparison)

■ Selection chart

■ Selection chart

■ Selection chart

15 16

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)

USFE typeUSF2 type

LFE typeLF type

Capacity (m3/min)

23

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Capacity (L /min) Capacity (L /min)

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Capacity (L /min) Capacity (L /min)

750W (NFK2 type)

150W 250W 400W

750W

750W (NFKtype)

150W 250W 400W

750W

(NFK2 type)type

type type

Page 10: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

17 18

Energy-saving inverter

NR typeN3-N type

● In case shallow well use(suction total head within -8m)

● In case receiver tank use(suction total head within -1m)

● At suction head 12m (using dedicated jet 6 to 12m)

● At suction head 24m (using dedicated jet 18 to 24m)

● At suction head 35m (using dedicated jet 30 to 35m)

● At suction head 30m (using dedicated jet 24 to 30m)

● At suction head 18m (using dedicated jet 12 to 18m)

50607080

40

30

20

100 10 20 30 40 50 60

250W750W

400W

50607080

40

30

20

100 10 20 30 40 50 60

750W400W250W

50607080

40

30

20

100 10 20 30 40 50 60

250W

400W750W

50607080

40

30

20

100 10 20 30 40 50 60

400W 750W

50607080

40

30

20

100 10 20 30 40 50 60

750W

. . . 250W*

. . . 400W

. . . 750W

●Adjustment rangeCan be set in 3 steps L (low), M (medium), or H (high) in the range shown on the left.

Note) The 250W can be set in 2 steps (L or H).

L

M

H

*For shallow well applications, please inquire.

Water supply with constant discharge pressure with inverter.SingleClean water 0~40˚C (no freezing)Suction total head:(single operation) -12m · -18m · -24m · -30m · -35mSuction total head:-7m (single operation)

Suction total head:-1m~In flow pressure within 5m

SCS13 or SUS304SUS304 (portion contacting liquid)SCS13Kawamoto PM motor TEFC indoor (250W~750W)Single phase100V (250W · 400W)Single phase 200V, Three phase 200V (400W · 750W) (*)Indoor/Outdoor (altitude:1,000m or less)

(NR model: 250W or less, N3-Nmodel: 400W or more)Control methodLiquid

Materials

ImpellerShaftCasing

Motor

Type

Phase/ Voltage

Speed

Installation

Control methodOperation methodLiquid

Suction condition

Materials

Motor

Installation

Control methodOperation methodLiquid

Suction condition

Materials

Motor

Installation

Water supply with constant discharge pressure with inverter.Alternate/ParallelClean water 0~40˚C (no freezing)Suction total head:-7 of suction total head

Suction total head:-1m~In flow pressure within 5m

SCS13SUS304 (portion contacting liquid)SCS13Kawamoto PM motor TEFC indoorSingle phase100V (250W · 400W)Single phase200V · Three phase200V (400W · 750W)Indoor/Outdoor (altitude:1,000m or less)

Shallow wellFor receiver tankImpellerShaftCasingType

Phase/Voltage

Deep wellShallow wellFor receiver tankImpellerShaftCasingType

Phase/Voltage

● When operating alternately (suction head -1m) ● When operating alternately/parallel (suction head -1m)

JF-A.P type

Control methodLiquid

Materials

Motor

Installation

Water supply with constant discharge pressure with inverter.Clean water 0~40˚C (no freezing)BronzeSUS304 (portion contacting liquid)SCS13Kawamoto PM motor (TEFC indoor) 4 polesSingle phase 100V (150W~400W)Single phase 200V (400W)Three phase 200V (400W)Indoor/Outdoor (altitude:1,000m or less)

ImpellerShaftCasingType

Phase/Voltage

Control method

Liquid

Materials

Motor

Installation

ImpellerShaftCasingTypePhase/Voltage

Water supply with constant discharge pressure with inverter.Clean water 0~45˚C (SFR (W)), Clean water 0~90˚C (SFRH (W))[Clean water]:pH5.8~8.6 chloride ion concentration 200mg/L or less

ResinAluminum CeramicsSCS13DC brush-less motor (TEFC indoor)Single phase100V (50Hz/60Hz)Indoor/Outdoor(Ambient temperature:-10~40˚C · Humidity:90%RH or less)

In case suction pressure: 0.05MPa.

*1100 / 1500W products are also available. Please inquire for detail.

JF type

In case clean water (0~45˚C)

In case hot water (46~90˚C)

10 20 30 40

20

16

12

8

4

0

150W SFRH (W)

SFR (W)

10

8

6

30

20

15

4 5 6 8 10 15 150100806050403020

750W400W

250W200W

130W150W

750W400W

250W

10

8

6

5

4

20

15

4 5 6 8 10 15 150100806050403020

200W

130W

150W

Well bore φ100 or

more

Well bore φ75 or

more

Well bore φ50

exclusive

For deep well jet

3 types of jet set supporting a wide range of well size.

For shallow well jet

Pic: NR type

Tota

l pum

p h

ead

Capacity

■ Features

■ Selection chart

■ Selection chart (JF type)

■ JF type Standard specifications

■ JF-A.P type Standard specifications

■ Standard specifications

■ Features

■ Selection chart (JF-A.P type)

■ Features

■ Features

■ Standard specifications

■ Standard specifications

■ Selection chart

■ Selection chart

KAWA-ACE Jet KAWA ACE

Tota

l hea

d (m

)

Capacity (L/min)

Capacity (L/min)

Capacity (L/min) Capacity (L/min)

Capacity (L/min)

Capacity (L/min) Capacity (L/min)

Capacity (L/min) Capacity (L/min)

Capacity (L/min)

Hot water auxiliary boosting equipment

Small booster pump unit

● Direct installation to the pipes is possible by Japan water works association certification.● NFD (N) 2 type (bore 13mm) are compatible with the common retracting pipe of bore 13mm. It can

also be a junction from retracting pipe of bore 20mm● Reservoir is not required and fresh water supply is possible.● Water supply from the main pipe is possible through check valve for by-pass in the case when suction

pressure being higher than the pump's startup pressure or unexpected shutdown. <By-pass system>● Noise and high frequency countermeasures are equipped as a standard with the noise filter and

built-in reactor.● In addition to overload/restraint protection, a freezing prevention function that forcibly operates the

pump by temperature detection sensor is equipped. This does not require a heater.

● Direct installation to the pipes is possible by Japan water works association certification.● Possible to install in desired places, compact and light weight, super slim pump unit.● Optimally controls with inverter and high efficient motor, which reduces power

consumption.● First in industry to realize constant discharge rate control in inverter be sealless pump. ● Rust free by using high quality stainless steel and PPS, and sealless enables no leak and

sanitary purposes. A sealless structure without a mechanical seal facilitates maintenance.

● By optimally controlling the pump speed according to the changes in working water rate with the inverter, constant estimated terminal pressure water supply with little with little fluctuation at the water supply terminal is possible regardless of fluctuation in the well water level.

● The wet sections of the pump and over ground automatic operation unit are both made mainly of stainless steel and resin and rubber. This enables clean water supply.

● The automatic operation unit has a compact design, smaller and lighter than the conventional pressure tank type enabling easy installation.

● NR type is a clean stainless steel casing.● Long-life and reliability improved by incorporat-

ing totally-closed motor.● A stable water supply is anticipated with

constant pressure water supply having both the pressure switch and the flow rate switch.

● Long-life by making no contact parts of electric components.

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)

Tota

l hea

d (m

)To

tal h

ead

(m)

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Tota

l hea

d (m

)

Reading the application diagram

Constant pressure water supplyClean water 0~40˚CBronzeSUS304 (portion contacting liquid)NR type:SCS13 N3-N type:Cast ironTEFC indoor

Single phase 100V (130, 150, 200, 250, 400W) Single phase 220V (250, 400, 750W)

Three phase 200V (200~750W)50Hz:3,000min-1

60Hz:3,600min-1

Indoor/Outdoor

NFD(N)2 type

SFR(W)·SFRH(W) type

JF type NR·N3-N type

Stainlesssteel

Capacity (L/min)

Tota

l hea

d (m

)

8 10 20 30 40 50 60

30

35

20

15

10

8

25

150W

250W

400W

Page 11: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Direct water supply booster pump unit

KFE-A·P type

Bore 32~65mmOutput 1.1~7.5kW

KF2-A·P type

Bore 32mmOutput 0.4~0.75kW

Bore 25~50mmOutput 0.75~7.5kW

KDP3 typeNDP2-G type

Bore 32~50mmOutput 0.75~7.5kW

Bore 20~25mmOutput 0.4~1.1kW

SDP-R type

Bore 80mmOutput 2.2~7.5kW

Bore 32~50mmOutput 0.75~7.5kW

Certificated products by Japan Water Works AssociationEnergy-saving inverter

Energy-saving inverter

Bore 80mmOutput 2.2~3.7kWKFED type

W counter flow prevention type

For 80mm intensified water supply equipment

Bore 32~65mmOutput 0.75~7.5kW

KDP3- typeDW

KF -T typeE2

KF typeEDD2

KVF-G type

Bore 50~65mmOutput 11~30kW

KF2-H type

Bore 40~50mmOutput 7.5~15kW

KFED-R type

(KFE-T type)

Stainless steel hand pump

HDS-25 type 380mL/StrokeLift up to 15m, suction -8m.

Production equipment, etc...

KF2-R type

Bore 32~65mmOutput 0.75~7.5kW

Pure waterElectrolysis water

Stainless steel & Variable speed control booster unit Refer to (P.14)

(KFED type)

HDS40(L) type 1400mL/StrokeLift up to 10m, suction -7m. (-3.5m)

*Inside the ( ) are HDS40L type.

NFG2 typeBore 20~32mmOutput 150~750W

JFG type (Water volume type)Bore 32mmOutput 250~750W

Stainless steel compact booster pump unit

Coolant Pump RC type

NFG2(-A·P)type JFG type

DJ

■ Features

Vortex Blower RA type■ Features

RC typeBore 40mm (65mm)Output 0.75~3.0kW (1.5~2.2kW)

* ( ) shows RCJ type

RA typeOutput 0.75~3.7kW

RCD type RCJ type

■ Features● For artesian/driven well water supply and emergency use.

■ Features● First in industry Automatic water supply unit for “Demineralized water”● The wet sections are made of material such as stainless steel, resin, and

flour rubber

■ Features● High energy-saving, PM motor

equivalent to IE5 is equipped.

■ Features● Energy-saving and quiet operation.

Clean, constant estimated terminal pressure high quality water supply

■ Features● Up to 6 rotary pumps can be

controlled to handle large water volumes. 

■ Features● This is the KF series high pressure type.

Water can be supplied in high-rise buildings with a total head of 170m. 

■ Features● Compact 3-unit multiple

control rotary.

■ Features● This is the high pump head type.

Water can be supplied to high-rise buildings with total head of 250m. Up to 6 rotary pumps can be controlled.

■ Features● Compact, light weight, and easy to install.

■ Features● Inspection of back flow prevention device is

possible without suspending the water supply.

■ Features● With the 2 inverter control with built-in

microcomputer, quiet operation with low pressure fluctuation and high energy-saving water supply is possible.

■ Features

ALL STAINLESS

ALL STAINLESSALL STAINLESS

● The pressure from the main water supply pipe is used for easy and waste-less direct-coupled water supply.

■ Features● Less output operation by 3 rotary controls

realized further energy-saving operation.

■ Features● For 80mm Intensified water supply equipment.● Back-flow prevention device is attached for

maintenance.● 3 rotary controls.

19 20

● Incorporating FCD500 for casing material realized a strong wear-resistant pump.

● Mechanical sealless structure prevents fluid from scattering by mechanical seal fracture.

● Fine curved impeller equipped as a standard. Compared to straight impeller, the air volume rises 5%.

● Designed in special rib form, which enables low noise.

Hand Pump

Kawamoto’s Pump Series for equipment

Water supply equipment / Small regional drinking water unit

Page 12: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Bore 40mmOutput 1.5kW, 2.2kWSuction -6m

Bore 40~50mmOutput 0.75~2.2kWFlow 0~5m

Bore 40, 50×40, 80×65mmOutput 0.4~3.7kW

Bore 32~80mmOutput 0.15~3.7kW

Temperature 0~60˚CBore 32~50mmOutput 1.9~7.5kW

Temperature hot water 85˚C (alternate / parallel type: 70˚C)Bore 20~32mmOutput 150~750W

Temperature Clean water 0~85˚CBore 40~50mmOutput 1.5~3.7kW

Energy-saving inverter

Hot water temperature 90˚C or less (80˚C in some models) (70˚C in USM type)Bore 32~65mmOutput 1.5~22kW

Energy-saving inverter

Bore 25mm Output 0.75kWReservoir Effective Capacity 60L Water level gage

■ Features

■ Features

■ Features

■ Features

■ Features

Self-priming automatic booster pump

Constant pressure automatic booster pump Self-priming plastic pump Refer to (P.4)

Titanium submersible pump

Stainless steel submersible clean water pump

Stainless steel hot water booster unit

Refer to (P.12)

Water seal vacuum pump unit

● The industry's first self priming type sea water supply unit which reduces the equipment costs and use the space effectively.For processing plant's cleaning and various sea water supply

● Automatic water supply unit for constant pressure sea water supply.Use this for fishing ports and fishmarket processing plants forwashing water and sea water supply.

● Self-priming pump construction does not require foot valve and makes priming works easier.

● High lifting performance is realized with high efficiency design.

● Titanium is used for the metal section Resin is used for the pump sections of this corrosion resistant, light weight drain pump.

● In water tank installation pump ● Super energy-saving. Hot water booster unit.

● For hot water pressurizing. User to pressurize hot water from boilers or solar-powered water heaters, etc.

● Adoption of hot water motor exclusive for hot spring. Available for a maximum water depth of 350 m and a maximum pump head height of 340 m

● Auto running vacuum pump with pump, control panel, reservoir, and water level gauge.

● The material is resistant to rust and best for sea water pump's water intake assist.

Stainless steel householdautomatic water supply pump

Stainless steel submersible hot spring pump

■ Features

■ Features

■ Features

■ Features

GSZB2 type

NFH2 type

KURH 2 3 type

GSP 3 4 typeKZB type

WUZ 2 3 -G type

KFEH type

USM(H) type

DW2 type

21 22

Special purpose / Sea water pump series

For hot water (hot spring) pump series

List of model

Model Installation Motor Liquid quality Temperature Shaft sealing *1 Phase Impeller *2 Shaft *2 Casing *2

● Centrifugal / Multistage pump

GSN(2)-C type Indoor / Outdoor TEFC outdoor Clean water 0~45°C M 1 or 3 Bronze SUS304 or SUS403 Cast iron with Nylon coating

FS type Indoor TEFC indoor Clean water agricultural water 0~40°C G or M 1 or 3 Cast iron SUS403 Cast iron

GSO2·3-C type Indoor TEFC outdoor Clean water river water 0~40°C M 1 or 3 Bronze or

SCS13 or Resin SUS304 Cast iron

GE-C type Indoor TEFC outdoor Clean water 0~90°C M 3 Bronze or Cast iron SUS304 Cast iron

KVS type Indoor (Outdoor) TEFC indoor or TEFC outdoor Clean water 0~90°C M 3 SCS13 or

SUS304 SUS316 SCS13

GE-2M type Indoor TEFC indoor Clean water 0~90°C G or M 3 Cast iron or Bronze SUS403 Cast iron

KR4·5-C type Indoor TEFC indoor Clean water 0~40°C M 3 Bronze or SCS13 or Resin SUS304 SCS13

GES-4M type Indoor TEFC indoor Clean water 0~90°C G or M 3 SCS14 SUS316 SCS13GRM type Indoor TEFC indoor ask S 3 SCS14 SUS316 SCS14PE(2) type Indoor / Outdoor TEFC outdoor Clean water 0~90°C M 1 or 3 SCS13 SUS304 Cast ironPSS(2) type Indoor / Outdoor TEFC outdoor Clean water 0~90°C M 1 or 3 SCS13 SUS304 SCS13T(N) type Indoor TEFC indoor Clean water 0~40°C G 3 Bronze SUS403 Cast ironTVS type Indoor TEFC indoor Clean water 0~40°C G 3 Cast iron SUS403 Cast ironKS type Indoor TEFC indoor Clean water 0~40°C G 3 Cast iron SUS403 Cast iron● Cascade / Oil pumpCS(2)-C type Indoor ODP or TEFC Clean water 0~40°C M 1 or 3 Bronze SUS304 or SUS403 Cast iron

OC(K) type Indoor TEFC indoor Kerosene, light oil, A type heavy oil 0~60°C M 3 Bronze SUS403 Cast iron

● Fire fighting pump

KTK-C type Indoor TEFC indoor Clean water 0~40°C M 3 Bronze SUS304 or SUS420J2Q Cast iron

KTY type Indoor TEFC indoor Clean water 0~40°C G 3 Bronze SUS403 Cast iron● Submersible clean water pumpUS2 type Submerged Canned Clean water 0~30°C 3 SCS13 SUS304 or SUS403 SCS13KUR2·3 type Submerged Canned Clean water 0~30°C O 3 SCS13 or Bronze SUS303 or SUS403 SCS13● Submersible Sump PumpWUO(3)-G type Submerged Dry-sealed For Sewage 0~40°C M 1 or 3 Resin SUS403 ResinZU3 type Submerged Dry-sealed For Sewage 0~40°C M 1 or 3 Cast iron SUS403 Cast iron● Water supply equipment / Small regional drinking water unitKFE-A·P ·T ·KF2·R type Indoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze or

SCS13 or Resin SUS304 SCS13

KF2-HR type Indoor TEFC indoor Clean water 0~40°C M 3 Bronze SUS304 SCS13KVF-G type Indoor TEFC indoor Clean water 0~40°C M 3 SCS13 SUS316 SCS13USFE·USF2 type Indoor (Outdoor) Canned Clean water 0~35°C 3LFE·LF2 type Indoor (Outdoor) Clean water 0~40°C 3KUF type Indoor Canned Clean water 0~30°C 3● Energy-saving inverter House holdNF3 type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze SUS304 SCS13

UF(L)2 type Indoor / Outdoor Canned Clean water 0~25°C 1 or 3 Resin withSUS304 or SCS13 SUS304 SCS13 and

SUS304 + Resin

UFE type Indoor / Outdoor Canned Clean water 0~25°C 1 Resin with SUS304 SUS304 SCS13 andSUS304 + Resin

JF type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 SCS13 SUS304 SCS13● Small booster pump unitNR type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze SUS304 SCS13+ ResinN3-N type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze SUS304 Cast iron● Hot water auxiliary boosting equipmentSFRH(W) /SFR(W) type Indoor / Outdoor TEFC indoor Clean water 0~90°C /

0~45°C S 1 Resin Alumina Ceramics SCS13

NFD(N)2 type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze SUS304 SCS13● Hand pumpHDStype 5~40°C SCS13● Water supply equipment / Small regional drinking water unitNDP2-G type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze SUS304 SCS13KDP3 type Indoor / Outdoor TEFC indoor Clean water 0~40°C M 1 or 3 SCS13 SUS304 SCS13

KFED·KFD2 type Indoor TEFC indoor Clean water 0~40°C M 1 or 3 Bronze orSCS13 or Resin SUS304 SCS13

● Sea water pump series

GSZB2·KZB type Indoor TEFC outdoor Sea water 0~40°C M 3 SCS14(KZB: Resin) SUS316 Cast iron with

Nylon coatingGSP3·4 type Indoor / Outdoor TEFC outdoor Sea water 0~60°C M 3 METTON® Resin SUS316 METTON® ResinWUZ2·3 type Submerged Dry-sealed Sea water Sewage 0~40°C M 1 or 3 Resin Titanium Resin● For hot water (hot spring) pump series

KURH2·3 type Submerged Canned Hot water Simple thermal 0~60°C O 3 SCS13 SUS403 SCS13

KFEH type Indoor TEFC indoor Hot water 0~85°C M 3 Resin SUS304 SCS13NFH2 type Indoor/Outdoor TEFC indoor Hot water 0~70°C (ask) M 1 or 3 Bronze SUS304 SCS13USM(H) type Submerged Canned ask 0~70°C (ask) 3 SCS13 SUS304 or SUS403 SCS13

*1 In shaft sealing column, symbols show following meanings. M: Mechanical seal, G: Gland packing, S: Seal-less, O: Oil seal with filter*2 In material column, symbols show following meanings. SCS: Stainless Cast Steel, SCS13: equivalent to 304 stainless, SCS14 equivalent to 316 stainless.

Page 13: From Intake, Circulation, Booster, Drainage and Wastewater ...water circulation Cooling water Filtration and circulation (swimming pool etc.) Hot spring Hot water boosting Energy-saving

Name

No. 5302 Y Ⓔ

Pump Series

Distributor

Specifications/configurations may be altered as a result of improvements and such. Unauthorized reproduction of this document is prohibited.

For any question about pumps, please contact your nearest distributor

Kawamoto Pump MFG. CO., LTD.Overseas Marketing Section11-39, Osu 4-Chome, Naka-ku, Nagoya460-8650, JAPAN

TEL: +81-52-251-7173 FAX: +81-52-747-5500E-mail: [email protected]://www.kawamoto.co.jp

Kawamoto products with this mark are products with excellent energy-saving and environmentally friendly features.

To reduce the environmental burden and protect the environment, we at KAWAMOTO PUMP will keep on carrying out activities as a united force under our slogan "Comfort Earth", as a company involved with the valuable resource that is "water".

Important Safety Precautions Always read the manual thoroughly and fully comprehend the contents for safe operation before starting use.Precautions for using products safely and for preventing personal injuries or physical damage are given in the manual. ※We bear no responsibility when the above listed precautions are not observed.

● Matters falling under the following may not be covered by the warranty: uses which go beyond the specified scope of applica-tion, failure to comply with precautions, improper repairs and alterations, matters arising from natural disasters, matters aris-ing from the installation environment (power source, foreign objects, sand etc.), non-compliance with laws and regulations or standards pertaining thereto, persons who suffer accidental or intentional damage or injury, replacement of consumable parts, defects due to resale, etc.

● Close attention is needed when rusting and corrosion/elution of metals are not permissible owing to the application or liquid. Take into account both the pump and the rest of the equipment when considering and selecting.

● Apply repair coating at an institute which supports your operat-ing environment. Depending on the operating environment, rust may form on screw parts, processed parts with anti-rust coating, anti-rust coated parts etc. due to high humidity, con-densation, getting wet etc., which may lead to unexpected damage.

● Close attention is needed in the case of circulation uses where rusting and corrosion/elution of metals are not permissible. Take into account both the pump and the rest of the equipment when considering and selecting. Unexpected damage may arise from condensation of circulating water.

● Select a product which is appropriate for your application. Inap-propriate use of products may cause accidents.

● Always use this pump within the specified product specifica-tions. Failure to do so could result in electric shock, fire, water leakage, etc.

● When using this pump for living things (fishery, fish tank, aquarium, etc.) or important equipment, always prepare a spare unit. If the pump fails, an oxygen deficiency or degradation of water quality, etc., could occur and affect the creature's life.

● If used to transport food-related items, give due consideration to the materials used. Contamination by foreign objects may occur.

● Avoid using this product with living things that are susceptible to copper alloys. The life of the creature could be affected.

● Do not connect the pump directly to water main pipes. Depend-ing on the country It may be prohibited under the Water Supply Act. Also, water backflow may contaminate tap water.

● Carry out installation in accordance with applicable legal requirements (electrical equipment guideline, interior wiring regulations, building codes, etc.) Failure to observe this may not only violate legal requirements, but could also result in fire or electric shock, or injury caused by falls or topples.

● Observe the service life of the pump, install it in a well venti-lated place free from corrosive or explosive gases, salt, mois-ture, water vapor, condensation etc., and avoid exposing it to wind, rain and direct sunlight. In a harsh environment, electric leakage, electric shock or fire may result from deterioration of insulation in the motor or control panel, etc.

● Do not use in places where people are assumed to get in con-tact with the product (baths, pools, lakes, etc.). Electric leak may occur and cause electric shock.

● Do not install in places with no drainage or places which have not been waterproofed. Water leaks may cause serious damage. * We bear no responsibility for any damage arising from lack of drainage or waterproofing.

● Depending on the equipment, attach a filter etc. appropriate for your application on the discharge side before use, perform thorough flushing and check that there is no contamination. Cutting oil, rubber mold releasing agent, foreign objects etc. from the manufacturing line and cutting oil, foreign objects etc. from the pipeline may contaminate the liquid which is to be handled.

● Install buzzers, etc., as an alarm to alert failure to be noticed. Failing to do so may result in serious accidents without notic-ing a failure.

● Do not attach phase-advancing capacitors to inverter equipped models. Doing so may cause fracture, abnormal heat, etc.

● When using generators in inverter equipped model, please consult our nearest sales office. Control panels(electrical com-ponent box) and generators may cause failure or fracture.

● Do not operate pumps with a specification of 50 Hz at 60 Hz. Damage may arise as a result of excess pressure or burnout of the motor etc. due to overload. Do not operate pumps with a specification of 60Hz at 50Hz. Pump performance may be reduced.

● Do not put the flammable items on the pump surroundings or inside the pump cover or control panel, or cover the pump, cable or control panel with the flammable items. Failure to observe this could overheat and result in burning.

● The Pump should never be disassembled, repaired, or modi-fied, or the power cable should never be replaced by anyone other than a qualified repair technician. Improper repairs could result in electric shocks, fires, faults or break

● It is recommended that both periodic and daily inspections be performed in order to ensure that the pump will operate reliably for as long as possible. Failure to perform inspections may lead to pump failure, accidents etc. For periodic inspec-tions, please consult your distributer or our nearest sales offices .