2
( DOWN] ( MANUAL] Disclaimer Statement FosPower sholl not be liable to you or anyone else for any loss.injury. hearing damage or damages relating to this product. FosPower shall not be liable for any damage or destruction to personal properties that are contained inside or outside the FosPower product. Specifications - Voltage: 12sVAC 60Hz - Max load: lsA Resistiveor Generol purpose - 12SVAC.60HZ.15A.Resistive - 125VAC.60HZ.1SA. General purpose - 125VAC.60HZ.tOA /1250W.Tungsten - 125VAC.60HZ.l/2HP TV-5 - Min Setting Time: 1 Minute - Operating temperature :-IO oC to +40 oC - Accuracy:+/- 1 minute per month - Battery backup: NiMH 1.2V > 1OOhours - INDOOR USEONLY - ETLListed Package Includes o _7 Day Digital Programmable Outlet Timer with Two Outlets x 1 - UserManual x 1 • lOON/OFF programs with I-minute interval • AUTO/MANUAL option • 12/24 hour mode selectable • LCD display with seconds. • Daylight Savings Time • Random function with random time activation of 10-31 minutes between 6.00pm and 6.00am • 16 options including 7 individual ones for each day of the week and 9 combinations for multiple days: MO/TU/WE/TH/FR/SA/SU MO. TU.WE.TH.FR.SA. SU MO. TU.WE.TH.FR I SA. SU MO. TU.WE.TH.FR.SA MO. WE.FR TU.TH.SA MO. TU.WE TH.FR.SA MO. WE.FR.SU • Maximum of 99 hours 59 minutes 59 seconds CD (Countdown) function. lnstoll Setup Before Operating 1. Charge the battery Plug the timer into a regulor 12SVwall outlet for 10-minutes to charge the back-up battery. 2. Reset the Timer Pressthe RESETbutton after charging to clear any data inmemory. 3. Set the Date and Time • PressSETbutton for 2-seconds until "MO" for Monday begins to flash. PressUPor DOWN button to select the day of the week. • PressSETbutton to advance to the "Hour" and "Minute" setting. • PressUPor DOWN button to select. • PressSETbutton one more time to complete setup. • To reset the current time. repeat the steps above. 4. 12/24 hour mode NOTE: The time on the system is by default 24-hour mode. PressCD and SETbutton simultaneously to change to 12-hour mode. "AM" will be in display. S. Daylight Savings Time PressMANUAL and SETbutton simultaneously to add I-hour for Daylight Savings and "S" will appear in the display. To set it back. press the two buttons simultaneously and "S" will disappear in the display. Program Timer • While in clock display. press UPbutton once to display the first ON setting 1ON -:-. • PressSETbutton once. the "MO" will begin to flosh. press UPor DOWN button to select the day of the week or combination of days for this program. • PressSETbutton again to advance to the "Hour" setting. PressUPor DOWN button to select. Repeat this step for the "Minute" setting. • Pressthe SETbutton to complete the program setting. • PressUPbutton again to advance to the first OFFsetting 10FF-:--. Repeat the procedure 2-5 to create the OFFsetting. • Repeat steps 1-7for additional ON/OFF program settings. • PressUPor DOWN button simultaneously to exit program setting mode. e

Fospower Digital Timer Manual - osInteractive

  • Upload
    others

  • View
    113

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Fospower Digital Timer Manual - osInteractive

•( DOWN]

( MANUAL]

Disclaimer StatementFosPower sholl not be liable to you or anyone else for any loss. injury.hearing damage or damages relating to this product. FosPower shallnot be liable for any damage or destruction to personal propertiesthat are contained inside or outside the FosPower product.

Specifications

- Voltage: 12sVAC 60Hz- Max load: lsA Resistiveor Generol purpose- 12SVAC.60HZ.15A.Resistive- 125VAC.60HZ. 1SA. General purpose- 125VAC.60HZ.tOA /1250W.Tungsten- 125VAC.60HZ.l/2HP TV-5- Min Setting Time: 1Minute- Operating temperature :-IO oC to +40 oC- Accuracy:+/- 1minute per month- Battery backup: NiMH 1.2V > 1OOhours

- INDOOR USEONLY- ETLListed

Package Includes

o_7 Day Digital Programmable Outlet Timer with Two Outlets x 1

- UserManual x 1

• lOON/OFF programs with I-minute interval• AUTO/MANUAL option• 12/24 hour mode selectable• LCD display with seconds.• Daylight Savings Time• Random function with random time activation of 10-31 minutes

between 6.00pm and 6.00am• 16 options including 7 individual ones for each day of the week

and 9 combinations for multiple days:MO/TU/WE/TH/FR/SA/SUMO. TU.WE.TH.FR.SA. SUMO. TU.WE.TH.FR

I SA. SUMO. TU.WE.TH.FR.SAMO. WE.FRTU.TH.SAMO. TU.WETH.FR.SAMO. WE.FR.SU• Maximum of 99 hours 59 minutes 59 seconds CD (Countdown)

function.

lnstoll Setup Before Operating

1. Charge the batteryPlug the timer into a regulor 12SVwall outlet for 10-minutes to chargethe back-up battery.2. Reset the TimerPressthe RESETbutton after charging to clear any data in memory.3. Set the Date and Time• PressSETbutton for 2-seconds until "MO" for Monday begins to

flash. PressUPor DOWN button to select the day of the week.• PressSETbutton to advance to the "Hour" and "Minute" setting.• PressUPor DOWN button to select.• PressSETbutton one more time to complete setup.• To reset the current time. repeat the steps above.4. 12/24 hour modeNOTE: The time on the system is by default 24-hour mode.PressCD and SETbutton simultaneously to change to 12-hour mode."AM" will be in display.S. Daylight Savings TimePressMANUAL and SETbutton simultaneously to add I-hour forDaylight Savings and "S" will appear in the display. Toset it back.press the two buttons simultaneously and "S" will disappear in thedisplay.

Program Timer

• While in clock display. press UPbutton once to display the first ONsetting 1ON -:-.

• PressSETbutton once. the "MO" will begin to flosh. press UPorDOWN button to select the day of the week or combination ofdays for this program.

• PressSETbutton again to advance to the "Hour" setting. PressUPorDOWN button to select. Repeat this step for the "Minute" setting.

• Pressthe SETbutton to complete the program setting.• PressUPbutton again to advance to the first OFFsetting 10FF-:--.

Repeat the procedure 2-5 to create the OFFsetting.• Repeat steps 1-7for additional ON/OFF program settings.• PressUPor DOWN button simultaneously to exit program setting

mode.

e

Page 2: Fospower Digital Timer Manual - osInteractive

Connect Devices to Timer

• Plug the timer into wall autlet.• Plug home appliances into the timer and then turn on homeapplionce.

Activate the Timer

PressMANUALbutton as necessary to display:"ON" - the plugged in device remoins ON"OFF" - the plugged in device remains OFF"AUTO" - the plugged in device follows the programmed timersettingsNote: When mode isswitched from MANUAL"ON" to "AUTO", thetimer will keep the setting of MANUAL"ON" until the next timerprogram is executed.-• To reset any current program, pressthe MANUALbutton in the

program setting mode. The display will replace current time with"-:--". If you only want to use a few of the ON/OFFprograms,please make sure the rest of the program setting displays "--:-".

• Check your programs to ensure that the settings do not overlap. Ifthey overlap, the limer will execute according to the programmedtime and not by program number. Program "OFF" has priority overprogram "ON".

• If you want to activate programs, please make sure the timer is in"AUTO" mode, and the "RANDOM" and "CD" functions are

disabled.

o

Random Function

• PressRNDbutton to activate random function. LCDdisplays "R".• When RANDOM function isactivated, the timer will be in "ON"

position randomly for I0-3I minutes during the time gap - from6.00pm to 6.00am

• PressRNDbutton to cancel this function. RANDOM function can'tbe set during PROGRAMand CD mode.

• The RANDOM function can only be executed in AUTOmodebetween 6.00pm and 6.00am.

Countdown Function

• Please make sure the current operation mode is in "AUTO" mode.The "Random" function isdisabled.

• While the timer isshowing clock display, pressDOWN button to setcountdown program. The "CD" signwill be in display.

• PressSETbutton once, either "ON" or "OFF" will begin to flash, pressUPor DOWN button to select countdown ON or OFFmode. If "ON"isselected the timer will be on during the countdown period. Thenit will turn off after the countdown expires, and vice versa.

• PressSETbutton again to advance to the "Hour" setting. PressUPorDOWN button to select. Repeat this step for the "Minute" and"Seconds" setting.

• PressSETbutton one more time to complete this countdownsetting.

• PressCD button once, this countdown program isactivated. Tostop the countdown, pressCD button once again and it will showthe time you have set.

• The"CD" will flash on the screen when pressCD button in clockmode. Thismeans the CD function isexecuted.

WARNINGS

• Do not plug more than two timers at once.• Do not plug in an appliance where the load exceeds 15Amp.• Always ensure the plug of any appliance is fully inserted into the

timer outlet.

• If cleaning of the timer is required, remove the timer from mainpower source and wipe it with a dry cloth. Do not immerse timer inwater or any other liquid.

• Heaters and similarappliances should never be left unattendedduring operation. The manufacturer recommends such appliancesnot to be connected with outlet timers.

o

Limited Lifetime ~arrantyThisproduct includes a limited lifetime warranty. Pleasevisit Fosf'owewebsite at www.fospower.com for more details.

Recy.cling the ProductTodispose this product properly, please follow the recycling proces:regulated in your area.

Follow Us On Social Media

Il@[email protected]@fospower.com© 2018FosPower Inc. All rights reserved.All trade names are registered trademarks of respectivemanufactures listed. I