Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Quick- Easy manipulation in only 2 steps- Semi-quantitative result within 10 minutes- Titration procedure available
Clinical studies- Evaluated by the NRC for Invasive Mycoses and Antifungals (Pasteur Institute, Paris) *- Evaluated by the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand (Johannesburg), Sriruttan C et al., ECCMID, 2016
Traceability - Compatibility with Biosynex® Reader for results recording- Positive and negative controls included
BIOSYNEX® CryptoPS
M Y C O L O G Y
For the semi-quantitative detection ofCryptococcus sp. antigens
in whole blood, serum, plasma and CSF
Positive
• T1 line appears at 25 ng/mL capsular antigen• T2 line appears at 2,5 µg/mL capsular antigen
CT2T1
CT2T1
CT2T1
BIOSYNEX SA22 Boulevard Sébastien Brant
67400 ILLKIRCH-GRAFFENSTADEN - FrancePhone : +33 3 88 77 57 52 - Fax : +33 3 59 81 21 74
E-mail : [email protected] FL
Y_1120
001_
EN_V
0120
1803
R01
THE SOLUTIONCryptotoccosis is an opportunistic and cosmopolitan disease caused by Cryptococcus neoformans. Infection occurs most often in childhood and by inhalation of spores. Cryptococcosis is the second leading cause of death in immunocompromised patients (HIV, transplants). The most common clinical expression of the disease is meningoencephalitis. There are approximately 1 million new cases each year worldwide including 625,000 deaths from cryptococcal meningitis (source: CDC). The vast majority of cases occur in Sub-Saharan Africa (> 70%), followed by Asia. BIOSYNEX® CryptoPS is a rapid immunochromatographic test for the semi-quantitative detection and titration of Cryptococcus sp. capsular antigens in serum, plasma, whole blood and CFS to guide the diagnosis of cryptococcal infections, especially in cases of meningitis.
• Automated reading of the results• Storage of the results• Printer, barcode reader and adhesive paper• LIS connectivity
Kit content
• 20 test cassettes• 20 pipettes (20 µL)• 1 dropper bottle of diluent• 1 bottle of diluent for the titration procedure• 1 bottle of positive control• Barcode card for test lot identi� cation when using BIOSYNEX® Reader
Procedure for semi-quantitative detection*
Biosynex® Reader
Product references
Bibliography
PerformancesBIOSYNEX®
CryptoPS
Speci� city 100%
Sensitivity 95%
• Ref. 1120001 - BIOSYNEX CryptoPS - 20 tests
• Ref. 5060001 - Biosynex® Reader - 1 reader
* Temfack E, et al., 2018, Front. Microbiol. 9:409.
Carefully read the instructions on the labellingand / or reagent and instrument notices.
1 2 3
Compared to another commercial rapid test.Internal study (voir notice).
CompatibleBIOSYNEX®
Reader
Results
* Titration procedure available on user instructions.
20µL
BIOSYNEX
opTricon Gesellschaft für optische Technologien (GERMANY)
Transfer 20 µL of sample (whole blood / serum / plasma / CSF) into
the well of the test cassette.
Add 3 drops of diluent. Read the result at 10 minutes, visually or using the Biosynex® Reader.
Negative
10