1 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
FLF-...22L (Ex d) and FLFE-...22L (Ex de) series lighting fixtures with LED tubes
TECHNICAL DATA SHEET NEW PRODUCT Rev. 0 – 05/2013
2 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
1. The symbol CE means "Conformité Européenne" and it shows that the item is complying the essential requirements of the Directives on safety, public health, consumer protection, ecc
2. N° of the registered body (CESI) responsible for production monitoring in accordance with Directive 94/9/CE ATEX
3. Denotes the equipment with explosion protection 4. Group II (surface devices) 5. Category 2 (suitable for zone 1 and 2 for gas and zone 21 and 22 for dust) 6. Gas and Dust (this material can be installed both in presence of gas and dust) 7. Protection mode for gas (Ex de: Explosion-proof enclosure with increased safety cable entry, IIC: gas
group) 8. Class of temperature 9. Epl – Equipment protection level 10. Protection mode for dust (Ex tb: protection for dust, IIIC: dust group) 11. Maximum temperature that the equipment can reach during operation with its relevant ambient tempe-
rature 12. Epl – Equipment protection level 13. IP protection
MARKING
ZONE 1 - 21 - 2 - 22
IP PROTECTION IP66
ATEX CERTIFICATION CESI 09 ATEX 008
IECEX CERTIFICATION IECEx CES 11.0021
CONFORMITY TO STANDARDS
ATEX 94/9/CE standard
EN60079-0, EN60079-1, EN60079-7, EN60079-31
OTHER CERTIFICATIONS Will follow upon market demand
CERTIFICATION DATA AND CONFORMITY TO STANDARDS
3 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
PRODUCT DESCRIPTION
Lighting fixtures for LED tubes FLF-...22L (Ex d) and FLFE-...22L (Ex de) series have two low copper con-
tent aluminium heads with G13 lamp holder, a tempered borosilicate glass tube, that is resistant to chan-
ges in heat, and a white painted aluminium reflector. Both the series are available with one tube or with two
tubes. FLFE-...22L series, in ‘Ex de’ way of protection, features an “Ex e” terminal board housing that al-
lows entry to the fixtures with a cable gland with an “Ex” seal (normal), while FLF-...22L series, in ‘Ex d’
way of protection, as specified in the appropriate installation standard (EN/IEC 60079-14), the entry to the
fixture must be through an Ex “barrier” cable gland (sealed) or, in the case of a conduit system, with an
EYS, EZS series sealing fittings.
The use of LED tubes, which have the same dimentions of fluorescent ones, allows to obtain economy in
operating costs, due to their long life, high-efficiency lighting, thanks to directional light, and LED light qua-
lity with a color rendering index of 85 (CRI).
Furthermore, LEDs do not ionize the particles of air around the lamp and do not attract, then, the dust par-
ticles suspended in the air.
The round cross section of the lighting fixtures provides a better “Cx” coefficient with less resistance to the
wind and less accumulation of dust. FLFE series has been designed to facilitate and speed up maintenan-
ce operations. As the electrical components are housed on a frame with guides, re-lamping is quick and
efficient. Furthermore, the different types of mounting attacks and the absence of sealing fittings make the
armor particularly performant.
Further advantages are as follows:
1) LED operation does not need heating times typical of discharge lamps. It has an instant lighting at star-
ting or restarting called instant restrike;
2) light diffusion is only in the visible spectrum avoiding, therefore, the emissions of UV rays (dangerous to
humans) or infrared radiation (they attract insects and do not facilitate cleaning operation);
3) the absence of heavy metals or toxic substances and their relevant disposal problems and environmen-
tal impact;
4) low class temperature T6;
5) LED tubes are supplied along with the lighting fixture.
MODELS AVAILABLE
Codes of models with one-tube Codes of models with two tubes
FLF (Ex d) series FLF-122L FLF-222L
FLFE (Ex de) series FLFE-122L FLFE-222L
4 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
CONSTRUCTIVE FEATURES
MACHANICAL FEATURES 1. Heads in aluminium alloy with low copper content, RAL7035 epoxy coated as a standard 2. Borosilicate glass tube, resistant to shocks and high temperatures 3. Internal mounting plate in aluminium, white painted, performing as a reflector too (standard) 4. Silicone resin between glass tube and aluminium heads 5. External protection in white painted aluminium and stainless steel protection guard (upon request) 6. PLG2IB plug and FL2IBK cable gland nickel plated brass (“Ex de” version), PLG2N plug(“Ex d” ver-
sion). 7. Neoprene sealing gaskets, resistant to acids and hydrocarbons 8. Stainless steel screws
ELECTRICAL FEATURES
• Rated Voltage: 100-240V
• Power: 1 or 2 tubes x 22 W
• Direct connection to terminal sboard L, N, Pe section 4mm2
• Bi-pin lamp-holder, type G13
• Internal wiring in silicone rubber cables, high temperature resistant
• Possibility to loop-in / loop-out connection betwe-en multiple installed fixtures
5 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
TEMPERATURE CLASS, MAXIMUM SURFACE TEMPERATURE, AMBIENT TEMPERATURE
Ambient Temperature Temperature Class Maximum surface temperature
-20°C +55°C T6 67°C
DIMENTIONAL DRAWINGS
FLFE SERIES
FLF SERIES
6 - New Product Technical Data Sheet - FLF-...22L and FLFE-...22L LED lighting fixtures
APPLICATION
• Manufacturing plants and process facilities: chemi-cal, petrochemical, refineries, pharmaceutical, Gas treatment and transport
• Areas with risk of explosion and fire due to abnor-mal, unusual or accidental presence of ignitible concentration of gases/vapours and dusts, even simultaneously
• On-shore, off-shore, naval and harbor installations
• Waste and or sewage treatment facilities
• Thermal plants
• Area with presence of combustible dusts such as joineries, sugarhouses, food industries with treat-ment and storage of wheat and derivatives
• Painting Systems
MARKET
• Industry
∗ Mechanical and electrical engineering
∗ Agribusiness
∗ Distillery
∗ Oil & Gas industries
∗ Pharmaceutical industries
∗ Energy
• Engineering and Contractors
∗ Project Design companies
∗ Electrical contractors
∗ Construction companies
• Electrical equipment distributors
• Shipyards / harbours
• Off-shore rig constructors
• On-shore treatment and refining plants
CORTEM GROUP
HEADQUARTERS AND FACTORY
Via Aquileia 10, 34070 Villesse (GO) ITALY
Tel +39 0481 964911
Fax +39 0481 964999
SALES
P.le Dateo 2, 20129 Milano ITALY
Tel +39 02 76110501
Fax +39 02 70005471
www.cortemgroup.com
PHOTOMETRIC DIAGRAM OF FLF-222L AND FLFE-222L SERIES