BBFireproof Ceiling SystemsFireproof Ceiling Systems
B215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Building new Solutions
Lindner fi reproof metal ceilings are systems for preventative fi re protection in interior fi nishing work, which have been tested and proven themselves many times over.
Perfected with detailed solutions and especially user friendly.
The concerns of design-oriented interior decoration are taken into account, and a very large range of dimensions and special developments are covered with offi cial test certifi cates.
A great number of varieties allow for the design requirements of architects and property develop-ers:
• Lay-on type• Hook-on type• Fold-down type, and our• Innovative drop-and-slide ceiling
Customised solutions with fi reproofi ng certifi cation are available on request.
B315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Table of Contents
Selection Criteria for Lindner Fireproof Ceilings ............................................................................................................ 4
LMD Ceilings, Tested for Stability acc. to French and Belgian Standards ..................................................................... 6
LMD F30 Ceilings with Swiss Fireproofi ng Certifi cation ................................................................................................ 7
LMD EI 30 Ceilings in acc. to with DIN EN 1364-2 – Lay-on type – ............................................................................ 8
Fireproof Metal Ceiling LMD F30-A/AB – Lay-on Type – ............................................................................................ 9
Fireproof Metal Ceiling LMD F30-A/AB – Hook-on Type – ........................................................................................ 13
Fireproof Metal Ceiling LMD F30-A/AB – Hook-on Type – Drop-and-Slide Function ................................................ 18
Fireproof Metal Ceiling LMD F30-A/AB – Fold-down Type – ..................................................................................... 22
Recessed and Surface-mounted Light Fittings for LMD F30 ...................................................................................... 35
Shut-off Valves and Ventilation Shutters for LMD F30 ................................................................................................ 36
Bridging Beam, F30 ..................................................................................................................................................... 38
Reduced Element Thickness, LMD F30 ...................................................................................................................... 39
Sprinklers in the Ceiling Cavity above Fireproof Ceilings ............................................................................................ 40
Inspection Hatch for Plasterboard Ceiling, F30 ........................................................................................................... 40
Project Examples ........................................................................................................................................................ 41
Fireproof Plasterboard Ceiling, LGKD, F30-A – Free-spanning System – ................................................................ 44
Fireproof Metal Ceiling LMD F90-A/AB – Lay-on Type – .......................................................................................... 45
Fireproof Metal Ceiling LMD F90-A/AB – Hook-on Type – ........................................................................................ 48
Fireproof Metal Ceiling LMD F90-A/AB – Hook-on Type, Drop-and-Slide Function – ............................................... 51
Fireproof Metal Ceiling LMD F90-A/AB – Fold-down Type – ..................................................................................... 54
Fireproof Metal Ceiling LMD F90-AB – Lay-on Type – with Flame Contact from above and below .......................... 57
Instructions for Installation and Use ............................................................................................................................ 58
Fundamental Principles of Fireproofi ng with Ceiling Systems ................................................. Section P: „Fireproofi ng“
Information on Surfaces and Perforation Patterns .......Section A: „Ceiling Systems“, starting from pages A70 and A71
B415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
1) Only F30 from above 2) All standard perforations are available up to 12 mm diameter of the holes and 30% free cross-section 3) Max. panel length of 2200 mm5) Addition with expert opinion
Selection Criteria for Lindner Fireproof Ceilingsacc. to with DIN 4102-2
Lay-on typeLMD F30-A/AB type 1/5
Hook-on typeLMD F30-A/AB type 3/4
Hook-on typeLMD F30-A/AB type 10/11
Building Supervisory General Certifi cates of Inspection P-3325/3258-MPA BS P-3132/4019-MPA BS P-3132/4019-MPA BS 5)
Type 1 Type 5 Type 3 Type 4 Type 10 Type 11
Without mineral wool x x x
Further information → See B 8 B 8 B 13 B 13 B 18 B 18
Requirements Independent F30 from above F30 from below
xx
xx
xx
xx
xx
xx
Panel dimensionsMax. length F30 from above F30 from below F30 from above and belowMax. width
3000 mm2500 mm2500 mm400 mm
2000 mm
500 mm
3000 mm3000 mm3000 mm400 mm
2000 mm
500 mm
3000 mm2610 mm2610 mm397 mm
2610 mm2610 mm2610 mm847 mm
3000 mm3000 mm3000 mm397 mm
2500 mm2500 mm2500 mm847 mm
3000 mm3000 mm3000 mm397 mm
2500 mm2500 mm2500 mm847 mm
3000 mm2610 mm2610 mm397 mm
2610 mm2610 mm2610 mm847 mm
SurfacesPlainPerforated 2)
Mikropor M
x 1)
xx
xxx
xxx
xxx
xxx
xxx
Further surfaces are available on request: stainless steel, aluminium, expanded metal, plasterboard, plain and perforated
Fold-down typeLMD F30-A/AB type 6/7
Fold-down typeLMD F30-A/AB type 6.2/7.2
Fold-down typeLMD F30-A/AB type 8/9
Building Supervisory General Certifi cates of Inspection P-3469/3599-MPA BS P-3310/0761-MPA BS P-3132/4019-MPA BS
Also smoke-tight followingDIN 18 095
Type 6 Type 7 Type 6.2 Type 7.2 Type 8 Type 9
Without mineral wool x x x
Further information → See B 22 B 22 B 28 B 28 B 31 B 31
Requests Independent F30 from above F30 from below
xx
xx
xx
xx
xx
xx
Panel dimensionsMax. length F30 from above F30 from below F30 from above and belowMax. width
3000 mm3000 mm3000 mm397 mm
2200 mm2200 mm2200 mm460 mm
3000 mm2500 mm2500 mm397 mm
2200 mm2200 mm2200 mm460 mm
2300 mm2300 mm2300 mm397 mm
2300 mm2300 mm2300 mm397 mm
3000 mm3000 mm3000 mm397 mm
2500 mm2500 mm2500 mm847 mm
3000 mm2610 mm2610 mm397 mm
2610 mm2610 mm2610 mm847 mm
SurfacesPlainPerforated 2)
Mikropor M
x 3)
xx
x 3)
xx
xxx
xxx
xxx
xxx
Further surfaces are available on request: stainless steel, aluminium, expanded metal, plasterboard, plain and perforated
B515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Selection Criteria for Lindner Fireproof Ceilingsacc. to with DIN 4102-2
Suspended ceiling without fi reproof-ing requirement in
little-used corridors
F30Tunnel design
F30 Suspended ceiling for refurbish-ments and special-purpose designs
F90 Suspended ceiling as special-
purpose design
Building Supervisory General Certifi cates of Inspection 3587/2850 -Mer- 6) P-3312/9019-MPA BS 5) 5)
Sound-absorbingliner
Ceilingpanels,perforated
Design example Design example
Without mineral wool Possible Possible - -
Further information → See From A 2 B 43 B 41
Requests Independent F30 from above F30 from below F90 from above
Without requirement F30 from the outside x x
Panel dimensionsMax. length F30 from above F30 from below F30 from above and below F90 from aboveMax. width
----
Upon request
2244 mm---
397 mm
2110 mm---
600 mm
---
2500 mm397 mm
SurfacesPlainPerforated 2)
Mikropor M
xx
xxx
xxx
xxx
Further surfaces are available on request: stainless steel, aluminium, expanded metal, plasterboard, plain and perforated
Lay-on typeLMD F90-A/AB type 2
Hook-on typeLMD F90-A/AB type 3
Hook-on typeLMD F90-A/AB type 5
Fold-down typeLMD F90-A/AB type 8
Building Supervisory General Certifi cates of Inspection
P-3261/5509-MPA BSP-3262/5519-MPA BS
P-3261/5509-MPA BSP-3262/5519-MPA BS
P-3261/5509-MPA BS 5)
P-3262/5519-MPA BS 5)P-3261/5509-MPA BS 5)
P-3262/5519-MPA BS 5)
Without mineral wool
Further information → See B 45 B 48 B 51 B 54
Requirements Independent F90 from above F90 from below
x x x x
Panel dimensionsMax. length F90 from above F90 from below F90 from above and belowMax. width
2500 mm
397 mm
2500 mm
397 mm
2500 mm
397 mm
1900 mm
297 mm
1700 mm
397 mm
SurfacesPlainPerforated 2)
Mikropor M
xxx
xxx
xxx
xxx
Further surfaces are available on request: stainless steel, aluminium, expanded metal, plasterboard, plain and perforated1) Only F30 from above 2) All standard perforations are available up to 12 mm diameter of the holes and 30% free cross-section 3) Max. panel length of 2200 mm4) Further widths available on request 5) Addition with expert opinion 6) Expert opinion
B615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Designation/type LMD-B 119 LMD-B 133 LMD-E 208System drawing
System description with fi reproof requirement
Grid-type metal ceiling system
Requirement SF-15Stability acc. to French
Standard „Arrêté du 3 août 1999 et son annexe II“
Grid-type metal ceiling system
Fold-down typeRequirement SF-30
Stability acc. to French Standard „Arrêté du 3 août
1999 et son annexe II“
Grid-type metal ceiling system
Fold-down typeRequirement SF-30
Stability acc. to French Standard „Arrêté du 3 août
1999 et son annexe II“Panel dimensionsMax. lengthMax. width
1250 mm675 mm
770 mm1745 mm
1200 mm750 mm
Finished fl oor height of ceiling element
30 mm 40 mm 40 mm
Longitudinal soundproofi ng - - -Total weight approx. 11 kg/m² approx. 10 kg/m² approx. 18 kg/m²SurfacesPlainPerforated
xAvailable on request
xAvailable on request
xAvailable on request
Reference projectsBuilt-over area
Coeur Defenseapprox. 10,000 m²
Tour Europeapprox. 400 m²
Tour Europeapprox. 2,000 m²
LMD-Ceilings, Tested for Stability acc. to with French and Belgian Standards
Tested in acc. to with the French Standard Arrêté du 3 août 1999 et son annexe II – „Stability“ Criterion
Tested acc. to Belgian Standard NBN 713-020 – „Stability“ Criterion
Designation/type LMD-B 134 LMD-E 209System drawing
System description with fi reproof requirement
Grid-type metal ceiling system
With longitudinal soundproofi ng
Requirement RF-30Stability in accordance with Belgian Standard
NBN 713-020
Metal ceiling systemFold-down typeWith longitudinal soundproofi ng
Requirement RF- 30Stability in accordance with Belgian Standard
NBN 713-020Panel dimensionsMax. lengthMax. width
2000 mm1200 mm
1788 mm597 mm
Finished fl oor height of ceiling element
62,5 mm 36 mm
Longitudinal soundproofi ng Dn,c,w: approx. 45 dB Dn,c,w: 49 dBDn,c,rose: 47 dB (A)
Total weight approx. 22 kg/m² approx. 24 kg/m²SurfacesPlainPerforated
xAvailable on request
xAvailable on request
Reference projectsBuilt-over area
Distri-Gazapprox. 6,000 m²
Berlaymont Brüsselapprox. 40,000 m²
Further details on these systems are available on request.
B715.0
Fireproof Ceiling Systems
LMD F30 Ceilings with Swiss Fireproofi ng Certifi cation
Certifi ed by the Vereinigung Kantonaler Feuerversicherer, or „VKF“
Cat
e-go
ry Ceiling, lay-on type Ceiling, hook-on type Ceiling, fold-down type
Fire
-pr
oof-
ing F30 F30 F30
Imag
es, p
rodu
ct a
bbre
viat
ions LMD F30-A/AB type 1/5 LMD F30-A/AB type 3/4 LMD F30-A/AB
LMD F30-A/AB type 10 LMD F30-A/AB type 8/9
Pro
duct
des
crip
tion The lay-on type ceiling elements are indi-
vidually removable.
Plain or perforated surface with powder coating.
Cladding on visible side is available with stainless steel.
Element dimensions:Length to 2500 mmWidth to 397 mm
Element thickness of 65 mm
Commercially available surface-mounted/recessed light fi ttings and speakers can be integrated in the ceiling elements.
With LMD F30-A/AB, type 3/4, the ceiling elements are individually removable or fold down toward the wall on the end side.
With LMD F30-A/AB, type 10, the ceiling elements drop down individually and slide under the adjoining elements in the longi-tudinal direction of the corridor.
Plain or perforated surface with powder coating
Cladding with stainless steel on the visible side is available.
Element dimensions:Length to 2500 mmWidth to 847 mm
Element thickness of 65 mm
Commercially available surface-mounted/recessed light fi ttings and speakers can be integrated in the ceiling elements.
The ceiling elements fold down individually and slide longitudinally in the direction of the corridor.
Plain or perforated surface with powder coating
Cladding with stainless steel on the visible side is available.
Element dimensions:Length to 2500 mmWidth to 847 mm
Element thickness of 65 mm
Commercially available surface-mounted/recessed light fi ttings and speakers can be integrated in the ceiling elements.
Cla
ssifi
catio
n Z 13125Z 12976
Classifi cationF30 from below
Z 12976Z 12977Z 12975
Classifi cationF30 from below
Z 12975Z 12977Z 12976
Classifi cationF30 from below
Subject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Further details on these systems are available on request.
B815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
LMD EI 30 Ceilings acc. to DIN EN 1364-2
Type 1/5, lay-on typeFig. 1 Fig. 2
Fig. 3 Butt-joint design
Type 1 no mineral wool
Type 5 with mineral wool
Lay-on systemThe ceiling elements are individually removable.
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (Plasterboard walls: allow for addi-
tional measures with single-layer-panelled plasterboard walls)
- Plasterboard fascias
- Execution as room ceiling with: • Centre frieze • Border frieze • Central suspension
- Built-in fi ttings possible: • Recessed light fi ttings • Recessed light low-voltage fi ttings • Surface-mounted light fi ttings • Speakers
k5686
~3
65
Width of themetal ceiling element
Width of themetal ceiling element
- Tested acc. to DIN EN 1364-2, EI 30 (a ↔ b) • Max. panel length 2500 mm with a panel width of 397 mm
- Tested acc. to DIN EN 1364-2, EI 30 (a ↔ b) • Max. panel length 2500 mm with a panel width of 397 mm
Further metal ceiling systems with classifi cation EI 30 (a ↔ b) available on request.
B915.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
Fig. 4
Type 1/5, lay-on type
Fig. 5
B1015.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 1/5, lay-on typeGeneral Technical Description
Fireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above or F30-AB2) from above and below.
System descriptionLay-on system: These metal ceiling elements rest on lay-on type L-trim on both sides and are individually remov-able.
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension• Cable-tray frieze (cables weighing up to max. 50 kg/m
can be put on this frieze construction.)
Metal ceiling panelsThese ceiling panels prefabricated at the factory consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproof-ing panels on the rear side. To obtain sound absorption through the suspended ceiling, the back of the metal ceil-ing panels can be lined with acoustic fl eece. A plain visible side is only possible with fl ame contact from above. Spe-cial surfaces such as stainless steel, anodised aluminium, Mikropor M, textured paint BER Metal-V, expanded metal or plasterboard cladding either plain or perforated are all available on request.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up to R’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 as per ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi t-tings as well as other types of light fi ttings from differ-
ent manufacturers. In conjunction with Lindner recessed light low-voltage fi ttings in the T38/… series, F30-metal ceiling elements can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm. Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc. Of course, various surface-mounted fi ttings can be fastened to these metal ceiling elements, such as light fi ttings, fi re alarms and escape route pictograms. A selection of Lind-ner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/designer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations are available on request.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
Combinable with drop-down, sliding and fold-down fi re-proof ceiling systems.
Type 1 no mineral wool
Type 5 with mineral wool
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above • 2500 mm with F30 from above and below with a panel width of max. 400 mm
• 2000 mm with F30 from above with a panel width of max. 500 mm
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 400 mm
• 2000 mm with F30 from above with a panel width of max. 500 mm
1) Only non-combustible building materials are used.2) All the essential building components are non-combustible. Non-essential components, such
as seals, may be fl ame resistant or normally fl ammable.
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1115.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 6 Corridor ceiling: free-spanning system from wall to wall
Fig. 7 Corridor/room ceiling with central suspension; butt joints executed with hairline gap or shadow gap
Fig. 8 Corridor/room ceiling, with plasterboard frieze on both sides
The self-supporting metal ceiling elements rest on the wall bracket construction.With corridor niches, T-butt joint designs, plasterboard friezes or central suspensions can be used.
k2302 k2303
k2991
Panel length As desiredAs desired
Panel length
Panel lengthPanellength
Panellength
Type 1/5, lay-on type
Fig. 9 Cable-tray frieze with connection to plasterboard partition wall
k13763
The cable tray ceiling can be connected to plasterboard partition walls, plasterboard fascias and solid partition walls.
The brackets that support the cable tray frieze and the F30-metal ceiling elements run here in the plasterboard partition wall up to the structural ceiling.
The connecting panel fastened at the upper end of the brackets is attached to the structural ceiling by anchors approved by building regulations.
- The brackets are fastened to the structural ceiling, pro-jecting clear and without suspension.
- The installations present in the ceiling cavity do not inter-fere.
- The plasterboard frieze for visual effect supports the ca-ble tray and additional loads of up to 50 kg/m on its rear side.
With
fascia
heig
hts
ofup
to1500
mm
�
Plasterboard friezeup to 500 mm Metal ceiling LMD F30 up to 2000 mm
Total width, e.g. both sides with plasterboard frieze of 500 mmand panel length of 2000 mm corridor width up to 3000 mm
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Panel length Panel length
40 40
65
�15
�10
40
65
Panel length
Fig. 12 End-side wall connection without shadow gap Fig. 13 Connection to plasterboard frieze design; frieze at same level
Fig. 10 Wall connection to plasterboard partition wall without shadow gap
Fig. 11 Wall connection to plasterboard partition wall with shadow gap
Fig. 14 Central suspension without shadow gap Fig. 15 Central suspension with shadow gap
k12812
k6834 k5739
k5952 k5951
Type 1/5, lay-on type
40 40Panel length Panel length
65
�15
65
40
Panel length
Panel width
65
65
�10 Panel length�750
k12813
1) Only required for the fi rst but joint of elements along the end side of the connection
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 3/4 hook-on typeFig. 16
Fig. 17
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 3 no mineral wool
Type 4 with mineral wool
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above with a panel width of max. 397 mm • 2610 mm with F30 from above and below with a panel width of max. 847 mm
- Max. axis length with panel ceilings • 857 x 857 mm with F30 from above and below with a
10-mm gap around the perimeter
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 397 mm • 2500 mm with F30 from above and below with a panel width of max. 847 mm
- Max. axis length with panel ceilings • 857 x 857 mm with F30 from above and below with a
10-mm gap around the perimeter
Type 3/4 hook-on typeGeneral Technical Description
Fireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above and below or F30-AB2) from above and below.
System descriptionHook-on system: These metal ceiling elements hook into carrier rails from below on both sides and are individu-ally removable downwards. On request, the ceiling panels can also swing off on the end side (shadow gap width of at least 25 mm).
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension• Cable-tray frieze (cables weighing up to max. 50 kg/m
can be put on this frieze construction.)
Metal ceiling panelsThese prefabricated ceiling panels consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproofi ng panels on the rear side. To obtain sound absorption through the sus-pended ceiling, the back of the metal ceiling panels can be lined with acoustic fl eece. Special surfaces such as stainless steel, anodised aluminium, Mikropor M, tex-tured paint BER Metal-V, expanded metal or plasterboard cladding either plain or perforated are all available on re-quest.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up toR’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 acc. to ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi ttings as well as other types of light fi ttings from different manu-facturers. In conjunction with Lindner recessed light low-
voltage fi ttings in the T30/… series, F30-metal ceiling ele-ments can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm.Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc.Of course, various surface-mounted fi ttings can be fas-tened to these metal ceiling elements, such as light fi t-tings, fi re alarms and escape route pictograms. A selec-tion of Lindner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/designer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations available on request.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
Combinable with drop-down, sliding and fold-down fi re-proof ceiling systems.
1) Only non-combustible building materials are used2) All the essential building components are non-combustible. Non-essential components, such as seals, may be fl ame resistant or normally fl ammable
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 18 Corridor ceiling: free-spanning system from wall to wall
Fig. 19 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 20 Corridor/room ceiling with central suspension, butt joints with hairline gap
Type 3/4 hook-on type
Fig. 21 Corridor/room ceiling with central suspension, butt joints with shadow gap
k5955
k5956k5953
k5954
Frieze widthas desired
Frieze widthas desired
Panel lengthPanel length
Panel length Panel length Panel length Panel length Panel length Panel length
Fig. 22 Cable-tray frieze with connection to plasterboard partition wall
k27300
The cable tray ceiling can be connected to plasterboard partition walls, plasterboard fascias and solid partition walls.
The brackets that support the cable tray frieze and the F30-metal ceiling elements run here in the plasterboard partition wall up to the structural ceiling.
The connecting panel fastened at the upper end of the brackets is attached to the structural ceiling by anchors approved by building regulations.
- The brackets are fastened to the structural ceiling, pro-jecting clear and without suspension.
- The installations present in the ceiling cavity do not inter-fere.
- The plasterboard frieze for visual effect supports the ca-ble tray and additional loads of up to 50 kg/m on its rear side.
He
igh
tu
pto
80
0m
m
Metal ceiling LMD F30 up to 2000 mm
Total width, e.g. both sides with plasterboard frieze of 500 mm
and panel length of 2000 mm corridor width up to 3000 mm�
Plasterboard friezeup to 500 mm
Plasterboard friezeup to 500 mm
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
5-38
65
~140
1)
140
Panel length
Fig. 23 Wall connection to plasterboard partition wall with shadow gap
Fig. 24 Ceiling element in swung-down position Joint width of at least 25 mm
k11408
Type 3/4 hook-on type
k17945
65
140
On request, the free-spanning system elements can also fold down on the end side. To do so, metal ceiling ele-ments weighing 22 kg or more are fi tted with reinforced corner constructions at the factory (not included in the standard design).
With joint widths from 15 mm, both the panels and the free-spanning system elements can be combined with fold-down elements LMD F30-A/AB, Type 8 and Type 9.
Fig. 25 Wall connection to solid wall with shadow gap
k12026
Fig. 26 Connection with plasterboard frieze construction, Frieze at higher level
k5958
Fig. 27 Connection with plasterboard frieze construction, Frieze at same level
k12288
~140
1)
140
65
5-38 Panel length
Panel length
65
~1
30
55
�750 Panel length�7505-20
~1
25
55 65
1) An overall height from 95 mm is available on request.
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1715.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 30 End-side wall connection with U-profi le
k11116
Type 3/4 hook-on type
k12293
Fig. 28 Connection to plasterboard fascia Fig. 29 Butt joint design
~3
65
Width of themetal ceiling element
Width of themetal ceiling element
Fig. 31 Central suspension with hairline gap
Fig. 33 Central suspension with shadow gap up to 30 mm
k5862
k5957
Fig. 32 Central suspension with shadow gap 6-10 mm
k11946
Panel length
65
~125
Panel length
�30
65
~125
Panel length Panel length
140
5-38 Panel length65
~140
1)
140
~140
1)
65
Panel width
Joint like longitudinal side
250
65
Panel length
~95
Panel length
�10
1) An overall height from 95 mm is available on request2) Only required for the fi rst but joint of elements along the end side of the connection
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 34
Type 10/11 hook-on type
Fig. 35
Each ceiling panel drops down and slides individually.
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B1915.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 11 no mineral wool
Type 10 with mineral wool- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 397 mm • 2500 mm with F30 from above and below with a panel width of max. 847 mm
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above with a panel width of max. 397 mm • 2610 mm with F30 from above and below with a panel width of max. 847 mm
Type 10/11 hook-on typeGeneral Technical Description
Fireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above and below or F30-AB2) from above and below.
System descriptionDrop-down and sliding system: These metal ceiling ele-ments hook into the carrier rails from below on both sides and can be individually dropped down and slid in the di-rection of the corridor. Openings can be changed as de-sired.
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension• Cable-tray frieze (cables weighing up to max. 50 kg/m
can be put on this frieze construction.)
Metal ceiling panelsThese prefabricated ceiling panels consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproofi ng panels on the rear side. To obtain sound absorption through the sus-pended ceiling, the back of the metal ceiling panels can be lined with acoustic fl eece. Special surfaces such as stainless steel, anodised aluminium, Mikropor M, tex-tured paint BER Metal-V, expanded metal or plasterboard cladding either plain or perforated are all available on re-quest.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up toR’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 acc. to ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi ttings as well as other types of light fi ttings from different manu-
facturers. In conjunction with Lindner recessed light low-voltage fi ttings in the T38/… series, F30-metal ceiling ele-ments can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm.Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc.Of course, various surface-mounted fi ttings can be fas-tened to these metal ceiling elements, such as light fi t-tings, fi re alarms and escape route pictograms. A selec-tion of Lindner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/designer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations available on request.This system is EP/DBP- and DBGM-protected.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
Combinable with lay-on type fi reproof ceiling systems.
1) Only non-combustible building materials are used2) All the essential building components are non-combustible. Non-essential components, such as seals, may be fl ame resistant or normally fl ammable
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2015.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 36 Corridor ceiling: free-spanning system from wall to wall
Fig. 37 Corridor/room ceiling with central suspension
Fig. 38 Corridor/room ceiling, with plasterboard frieze on both sides, at higher level
k18652 k18651
k18654
Type 10/11 hook-on type
Panel length Panel lengthPanel length
Panel lengthAs desired As desired
Fig. 39 Corridor/room ceiling, with plasterboard frieze on both sides, at same level
k18653
Panel lengthAs desired As desired
Fig. 40 Cable-tray frieze with connection to plasterboard partition wall
k27301
The cable tray ceiling can be connected to plasterboard par-tition walls, plasterboard fascias and solid partition walls.
The brackets that support the cable tray frieze and the F30-metal ceiling elements run here in the plasterboard partition wall up to the structural ceiling.
The connecting panel fastened at the upper end of the brackets is attached to the structural ceiling by anchors approved by building regulations.
- The brackets are fastened to the structural ceiling, pro-jecting clear and without suspension.
- The installations present in the ceiling cavity do not inter-fere
- The plasterboard frieze for visual effect supports the ca-ble tray and additional loads of up to 50 kg/m on its rear side.
He
igh
tu
pto
80
0m
m
Plasterboard friezeup to 500 mm
Metal ceiling LMD F30 up to 2000 mm
Plasterboard friezeup to 500 mm
Total width, e.g. both sides with plasterboard frieze of 500 mmand panel length of 2000 mm corridor width up to 3000 mm�
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2115.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
~165
65
170
15 ~5 Panel length10-40
1)
Fig. 43 Connection to plasterboard frieze design; frieze at same level
Fig. 41 Wall connection to solid wall with shadow gap Fig. 42 Connection to plasterboard frieze design; frieze at higher level
Fig. 44 End-side wall connection with U-profi le
k18612
k18670 k12074
Type 10/11 hook-on type
k18594
Fig. 45 Central suspension with hairline gap
k18613
�750 15 ~5 Panel length
65
~155
Panel length
65
~150
~515�750
~165
1)
65
160
Joint like longitudinal side
Panel length
270
65
~150
15 ~5 Panel length15~5Panel length
1) Overall height from 120 mm is available on request.2) Only required for the fi rst but joint of elements along the end side of the connection
Fig. 46 T-butt joint construction
k18786
280
90
Panel width 10 15 ~5 Panel length
86
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 47
Type 6/7 fold-down type
Fig. 48
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 7 no mineral wool
Type 6 with mineral wool- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 397 mm
• 2200 mm with F30 from above and below with a panel width of max. 460 mm
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above • 2500 mm with F30 from above and below with a panel width of max. 397 mm
• 2200 mm with F30 from above and below with a panel width of max. 460 mm
Type 6/7 fold-down typeGeneral Technical Description
Fireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above and below or F30-AB2) from above and below.
System descriptionFold-down system: These metal ceiling elements rest in G-profi les on both sides and can be individually folded down and slid along in the direction of the corridor.
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension• Cable tray frieze (cables weighing up to max. 50 kg/m
can be put on this frieze construction.)
Metal ceiling panelsThese prefabricated ceiling panels consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproofi ng panels on the rear side. To obtain sound absorption through the sus-pended ceiling, the back of the metal ceiling panels can be lined with acoustic fl eece. With fl ame contact from be-low in conjunction with Type 6 and Type 7 LMD F30 sus-pended ceilings, a plain visible side is only possible up to a maximum panel length of 2,200 mm. Special surfaces such as stainless steel, anodised aluminium, Mikropor M, textured paint BER Metal-V, expanded metal or plaster-board cladding either plain or perforated are all available on request.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up toR’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 acc. to ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi ttings as well as other types of light fi ttings from different manu-
facturers. In conjunction with Lindner recessed light low-voltage fi ttings in the T38/… series, F30-metal ceiling ele-ments can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm.Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc.Of course, various surface-mounted fi ttings can be fas-tened to these metal ceiling elements, such as light fi t-tings, fi re alarms and escape route pictograms.A selection of Lindner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/de-signer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations available on requestThe suspension and locking elements are DBP-protect-ed.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
Combinable with lay-on and hook-on type fi reproof ceiling systems.
1) Only non-combustible building materials are used2) All the essential building components are non-combustible. Non-essential components, such as seals, may be fl ame resistant or normally fl ammable
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 51 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 49 Corridor ceiling: free-spanning system from wall to wall
Fig. 50 Corridor/room ceiling with central suspension
k5754
k5756
Type 6/7 fold-down type
k5752
Fig. 52 Corridor/room ceiling with border frieze and centre frieze
k5760
Panel length Panel length Panel length
Panel length
As desired As desired As desired As desired As desired
Panel length Panel length
Fig. 53 Cable-tray frieze with connection to plasterboard partition wall
k27302
The cable tray ceiling can be connected to plasterboard partition walls, plasterboard fascias and solid partition walls.
The brackets that support the cable tray frieze and the F30-metal ceiling elements run here in the plasterboard partition wall up to the structural ceiling.
The connecting panel fastened at the upper end of the brackets is attached to the structural ceiling by anchors approved by building regulations.
- The brackets are fastened to the structural ceiling, pro-jecting clear and without suspension.
- The installations present in the ceiling cavity do not inter-fere.
- The plasterboard frieze for visual effect supports the ca-ble tray and additional loads of up to 50 kg/m on its rear side.
He
igh
tu
pto
80
0m
m
Plasterboardfrieze up to
500 mm
Plasterboardfrieze up to
500 mm
Metal ceiling LMD F30 up to 2000 mm
Total width, e.g. both sides with plasterboard frieze of 500 mm
and panel length of 2000 mm corridor width up to 3000 mm�
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
�750Panel length Panel length~3 ~3
65~
12
5
2828
Fig. 57 Suspension with centre frieze construction
k5768
Fig. 58 Central suspension with hairline or shadow gap
k5784
Panel length�750
55 65
~120
~328
Fig. 55 Connection to plasterboard frieze design; frieze at same level
Fig. 56 Connection to plasterboard frieze design; frieze at higher level
k5782
k10065
Type 6/7 fold-down typeFig. 54 Connection to plasterboard fascia or
plasterboard partition wall
k12306Panel length12-45 28 ~3
65
140
~1
30
1)
Panel length~328�750
~125
65
1) Overall height from 93 mm is available on request. k5865
Fig. 59 Corridor intersection (T-butt joint), change in direction
Panel length Panel length
65
~1
20
200
~3 ~328 28
�30
28 ~3�3028
Panel width
~120
Panel length
65
200
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
2812-45 ~3 Panel length
15
14
4
140
65
140
~40 ~3 Panel length
65
12
9
~3
140
28
65
~1
30
1)
Joint like longitudinal side
Panel width
Fig. 62 Ceiling panel also with expanded metal on the visible side *
Fig. 60 End-side wall connection with U-profi le
Type 6/7 fold-down type
k5346
Fig. 61 End-side wall connection with G-profi le
k5772
1) Overall height from 93 mm is available on request* Customised design
Fig. 63 Wall connection with inclined G-profi le *
k26077
Fig. 64 Wall connection with 83 mm high G-profi le *
k26078
Fig. 65 Wall connection with 57.5 mm high G-profi le *
k26079
140
~3�50 Panel length
65
128
140
Joint like longitudinal side
65
~130
1)
Panel width
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B2715.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F30-AB-RD acc. to DIN 4102-2
Fig. 66 Fig. 67 Standard operation
Fold-down system with additional functionRD = smoke-tight
The ceiling elements fold down and slide along the longi-tudinal side.In addition, the ceiling system is equipped with a further sealing level (duplex) to provide smoke-tightness.
Fire protection and smoke protection in one system
- Classifi cation • Smoke-tight from above and below, acc. to the test criteria of DIN 18 095
• Independent, acc. to DIN 4102-2 F30 from above and below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 397 mm
• 2200 mm with F30 from above and below with a panel width of max. 460 mm
k5206
LMD F30-AB-RD Type 6 fold-down type
Suspension andLocking ElementsProtected asregistered designs
Fig. 68 Alternatively with central suspension
Fig. 69 Alternatively with operation by screwdriver, hexagon or square socket spanner
k17111
B2815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
Type 6.2/7.2 fold-down typeFig. 70
Fig. 71
B2915.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
Type 7.2 no mineral wool
Type 6.2 with mineral wool- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 2300 mm with F30 from above and below with a panel width of max. 397 mm
- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 2300 mm with F30 from above and below with a panel width of max. 397 mm
Type 6.2/7.2 fold-down typeGeneral Technical Description
Fireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above and below or F30-AB2) from above and below.
System descriptionFold-down system: These metal ceiling elements rest in a hook-on profi le on both sides and can be individually folded down and slid in the direction of the corridor.
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension
Metal ceiling panelsThese ceiling panels prefabricated at the factory consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproofi ng panels on the rear side. To obtain sound absorption through the suspended ceiling, the back of the metal ceiling panels can be lined with acoustic fl eece. Special surfaces such as stainless steel, anodised aluminium, Mikropor M, tex-tured paint BER Metal-V, expanded metal or plasterboard cladding either plain or perforated are all available on re-quest.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up toR’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 acc. to ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi ttings as well as other types of light fi ttings from different manu-facturers. In conjunction with Lindner recessed light low-voltage fi ttings in the T38/… series, F30-metal ceiling ele-
ments can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm.Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc.Of course, various surface-mounted fi ttings can be fas-tened to these metal ceiling elements, such as light fi t-tings, fi re alarms and escape route pictograms.A selection of Lindner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/de-signer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations available on request.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
1) Only non-combustible building materials are used2) All the essential building components are non-combustible. Non-essential components, such as seals, may be fl ame resistant or normally fl ammable
B3015.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Panel length Panel length�515 �515
140
15 ~3 Panel length
65
~130
1)
13-44
140
15 ~3 Panel length
65
~130
13-44
1)
140
Panel width
Joint like longitudinal side
~130
1)
�515 ~3 Panel length
65 ~
95
Fig. 74 Wall connection to solid wall
Fig. 72 Corridor ceiling: free-spanning system from wall to wall
Fig. 73 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 75 Connection to plasterboard fascia
k21495
k21624 k21536
Type 6.2/7.2 fold-down type
k21508
Fig. 76 End-side wall connection with U-profi le
k21518
Fig. 77 Connection to plasterboard frieze design; frieze at same level
k21534
1) Overall height from 93 mm is available on request2) Only required for the fi rst but joint of elements along the end side of the connection
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B3115.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 78
Type 8/9 fold-down type
Fig. 79
The panels can be individually removed, folded down and slid.
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B3215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Type 9 no mineral wool
Type 8 with mineral wool- Classifi ed as independent, acc. to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above and below with a panel width of max. 397 mm • 2500 mm with F30 from above and below with a panel width of max. 847 mm
- Max. Axis length with panel ceilings • 857 x 857 mm with F30 from above and below with a 10 mm gap around the perimeter
- Classifi ed as independent, acc .to DIN 4102-2 • F30 from above • F30 from below
- Max. panel length • 3000 mm with F30 from above with a panel width of max. 397 mm • 2610 mm with F30 from above and below with a panel width of max. 847 mm
- Max. Axis length with panel ceilings • 857 x 857 mm with F30 from above and below with a 10 mm gap around the perimeter
Type 8/9 fold-down typeGeneral Technical DescriptionFireproofi ngClassifi cation as independent fi reproof ceiling acc. to DIN 4102-2, F30-A1) from above and below or F30-AB2) from above and below.
System descriptionFold-down system: These metal ceiling elements hook into carrier rails from below on both sides and can be in-dividually folded down and slid in the direction of the cor-ridor.
Connections are possible to• Solid walls (concrete and masonry)• Light partition walls (Plasterboard walls: allow for
additional measures with single-layer-panelled plasterboard walls)
• Plasterboard skirting• Large-surface fi reproof panel ceilings (such as
plasterboard ceiling, at least F30)
Execution as room ceiling with• Centre frieze• Border frieze• Central suspension• Cable tray frieze (cables weighing up to max. 50 kg/m
can be put on this frieze construction.)
Metal ceiling panelsThese ceiling panels prefabricated at the factory consist of galvanised steel sheet acc. to DIN EN 10 142/10 152 with powder coating on the visible side and fi reproofi ng panels on the rear side. To obtain sound absorption through the suspended ceiling, the back of the metal ceiling panels can be lined with acoustic fl eece. Special surfaces such as stainless steel, anodised aluminium, Mikropor M, tex-tured paint BER Metal-V, expanded metal or plasterboard cladding either plain or perforated are all available on re-quest.
Sound protectionSound insulating in single defl ection depending on the design of the constructional elements adjoining on the sides; up toR’w,P = 30 dB acc. to DIN 52 210. Sound absorption αw = 0,45 – 0,65 acc. to DIN EN ISO 11654 NRC = 0,45 – 0,75 acc. to ASTM C 423
Lights and other recessed/surfaced-mounted fi ttingsThe ceiling system is compatible with Lindner light fi ttings as well as other types of light fi ttings from different manu-facturers. In conjunction with Lindner recessed light low-voltage fi ttings in the T38/… series, F30-metal ceiling ele-
ments can be realised with built-in recessed light fi ttings from an overall installation height of 65 mm.Other built-in fi ttings are also possible, such as speakers, ventilation shut-off valves, sprinklers, fi re alarms, etc.Of course, various surface-mounted fi ttings can be fas-tened to these metal ceiling elements, such as light fi t-tings, fi re alarms and escape route pictograms.A selection of Lindner light fi ttings can be found in the LIGHTING index to this catalogue. Special-purpose/de-signer light fi ttings are available on request.
Special featuresAvailable as a heated/chilled ceiling.Various perforation suggestions can be found on page A72.Special perforations available on request.
Installation and useThe installation and use must be carried out in compli-ance with the manufacturer‘s guidelines and the building supervisory general certifi cate of inspection.
Combinable with lay-on type fi reproof ceiling systems.
1) Only non-combustible building materials are used2) All the essential building components are non-combustible. Non-essential components, such as seals, may be fl ame resistant or normally fl ammable
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B3315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 84 Cable-tray frieze with connection to plasterboard partition wall
Fig. 80 Corridor ceiling with free-spanning system from wall to wall
Fig. 82 Corridor/room ceiling with plasterboard frieze on both sides
Fig. 81 Corridor/room ceiling with central suspension; butt joints with shadow gap
k17948
k11128
k17951
Type 8/9 fold-down type
Fig. 83 Corridor/room ceiling with border frieze and centre frieze
k11129
Panel length
Panel lengthAs desired As desired
Panel length Panel length
Asdesired
Asdesired
Asdesired
Panel length Panel length
k27300
The cable tray ceiling can be connected to plasterboard partition walls, plasterboard fascias and solid partition walls.
The brackets that support the cable tray frieze and the F30-metal ceiling elements run here in the plasterboard partition wall up to the structural ceiling.
The connecting panel fastened at the upper end of the brackets is attached to the structural ceiling by anchors approved by building regulations.
- The brackets are fastened to the structural ceiling, pro-jecting clear and without suspension.
- The installations present in the ceiling cavity do not inter-fere.
- The plasterboard frieze for visual effect supports the ca-ble tray and additional loads of up to 50 kg/m on its rear side.
He
igh
tu
pto
80
0m
m
Metal ceiling LMD F30 up to 2000 mm
Total width, e.g. both sides with plasterboard frieze of 500 mm
and panel length of 2000 mm corridor width up to 3000 mm�
Plasterboard friezeup to 500 mm
Plasterboard friezeup to 500 mm
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
B3415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
�30 Panel lengthPanel length
~1
25
65
140
~140
1)
Panel width
Joint like longitudinal side
Panel length�750 10-20
~1
25
65
55
140
10-36 Panel length
65
~140
1)
Panel length�750
65
~1
30
55
50
10-36
140
65
~140
1)
Panel length
Fig. 88 Connection to frieze construction, Frieze at same level
Fig. 85 Wall connection to solid wall with shadow gap
Fig. 87 Connection to plasterboard frieze design; frieze at higher level
Fig. 89 End-side wall connection with U-profi le
k11135 k11409
k11134
Type 8/9 fold-down type
k12036
Fig. 86 Connection to plasterboard fascia
k12298
Fig. 90 Central suspension with shadow gap up to 30 mm
k12295
Fireproof Ceiling LMD F30-A/AB acc. to DIN 4102-2
1) An overall height from 95 mm is available on request2) Only required for the fi rst but joint of elements along the end side of the connection
B3515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Recessed and Surface-mounted Light Fittings for LMD F30-Ceilings acc. to DIN 4102-2
Recessed light fi ttings T38
Surface-mounted and recessed light fi ttings
Fro
m65
65
k21528
Fig. 91 Fireproof ceiling element with built-in light fi tting
k21527
Fig. 92 Fireproof ceiling element with protective casing for lighting unit
Fireproof ceiling elements F30 with built-in T38 re-cessed light fi tting, without additional protective cas-ing; height of element incl. recessed light fi tting: from 65 mm
Cable trays and installations in the ceiling cavity are no longer an obstruction.
The dimensions and surfaces of the recessed light fi ttings are geared to the F30 fi reproof ceiling systems.
For details on the recessed light fi ttings, see Sec-tion D „Lighting Systems“.
Commercially available surface-mounted and recessed light fi ttings can be integrated.
• Surface-mounted light fi ttings without additional suspension
• Surface-mounted light fi ttings with additional suspension
• Recessed light fi ttings with protective casing without additional suspension
• Recessed light fi ttings with protective casing and additional suspension
Our protective casings can also be used to integrate other recessed components (such as speakers, smoke alarms, etc).
F30 fi re protection from above and below is guaranteed acc. to DIN 4102.
B3615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
It is possible to install F30 ventilation and shut-off valves in fi reproof metal ceilings.
One must, however, be sure that the ventilation valves are certifi ed for LMD F30-A/AB fi reproof ceilings.
The building supervisory general certifi cates of inspection are issued b the Deutsches Institut für Bautechnik in Ber-lin.
What ceiling systems these may be installed in can be taken from the information in this certifi cation.
The components are usually installed in panels prepared by the factory with cut-outs and sheathing.
k5688
Fig. 93 Circumstances of installation for shut-off valve
Panel width
Shut-off Valves and Ventilation Valves in LMD F30 Ceilings acc. to DIN 4102-2
Possible built-in ventilation components in LMD F30 ceilings
Make Strulik BCF
Strulik BTZ
Strulik BW-K30U
Trox FVZ-K30
Trox KU-K30
Wildeboer BV90 NEU
Wildeboer FKU30
Certifi cation number Z-41.3-331 Z-41.3-549 Z-41.3-335 Z-41.1-319 Z-41.3-320 Z-41.3-639 Z-41.3-304
Installation is possible in LMD-type ceilings
Lay-on type F30 type 1F30 type 5
xx
xx
xx
xx
x 4)
x 4)xx
xx
Hook-on type
F30 type 3F30 type 4F30 type 10F30 type 11
xxxx
xxxx
xxxx
xxxx
x 4)
x 4)
x 4)
x 4)
xxxx
xxxx
Fold-down type
F30 type 6F30 type 6.2F30 type 7F30 type 7.2F30 type 8F30 type 9
xx 2)
xx 2)
xx
x
x
xx
xx 2)
xx 2)
xx
x
x
xx
x 4)
x 1) 4)
x 4)
x 1) 4)
x 4)
x 4)
xx 2)
xx 2)
xx
x
x
xx
Maximumpanel width 847 mm 400 mm 847 mm 847 mm 3) 847 mm 400 mm
Ventilation tech specs The ventilation tech specs should be inquired about directly from the respective manu-facturer, depending on the circumstances of installation and the requirements.
1) Panel thickness 65 mm2) Panel thickness of at least 58 mm3) The width of the LMD F30 fi tting elements is geared to the size of the fi re protection valve.4) Max. length of the connecting panels going through: 2,300 mm
B3715.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Shut-off Valves and Ventilation Shutters in LMD F30 Ceilingsacc. to DIN 4102-2
Installation example for Trox L-KU K30 fi re protection valveFig. 94
- Possible sizes of the fi re protection valve: NW 300, 400, 500, 600 and 625
- Integration of the air vent fl ush with surface
- Various swirl diffusers are possible.
- Installation is possible in: • Lay-on type ceilings LMD F30, type 1/5 • Hook-on type ceilings LMD F30, type 3/4 • Drop-and-slide ceilings LMD F30, type 10/11 • Fold-down ceilings LMD F30, type 6/6.2/7/7.2/8/9 • Fitting panels next to air vents are geared to the width of the ventilation component.
Fig. 95 Plan view of ceiling for installing Trox L-KU K30
Fig. 96 Section A - A Trox L-KU K30 in LMD F30-ceiling
Width W ( 687)�
�2
30
0
Le
ng
thL
of
the
fitt
ing
pa
ne
l
Width W
AA
AA
Width W
65
30
80
3 Dimension C 3
Dimension A
Length L Length L
Fire protection valveTROX KU-K30
Cover
Threaded rod M8
Sealing tape
k25502
B3815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 97 Bridging beam connection to solid partition wall
Bridging Beam F30 acc. to DIN 4102-2
Bridging beams which in case of fi re would be exposed to the fi re have to either be tested together with the fi re-proof ceiling and be certifi ed in a joint building supervisory general certifi cate of inspection; or the supports have to be certifi ed separately acc. to DIN 4102. In a support sys-tem certifi ed separately from the ceiling, however, it has to be possible for it to be classifi ed one class higher than the suspended ceiling, such as ceiling F30 and bridging beam F60.
Lindner bridging beams F30 Type 100 have been tested in conjunction with all LMD F30-A/AB fi reproof ceilings and certifi ed for spans up to 4500 mm.
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (Plasterboard walls: allow for ad-
ditional measures)
- Optional suspension from the structural ceiling is possible.
- It is possible for installation loads to be assumed.
k13909
Fig. 98 Plasterboard frieze and fi reproof ceiling mounted directly on bridging beam; free-spanning system from wall to wall
Frieze width 15
65
Bridging beam F30, type 100
Panel length
Total width of corridor: approx. 1700
Installations carriedout by the customer
Spans are possible up to 4.500 mm
- Installations put in by customers cause no obstruction.
- Low construction heights due to no additional suspen-sion being required
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (Plasterboard walls: allow for ad-
ditional measures)
- It is possible for installation loads to be assumed.
k16769
B3915.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Safetydistance * Safety distance *
Room
heig
ht
Room
heig
ht
+14
mm
51
�5
0
�50
65
*
Reduced Element Thickness with LMD F30 Ceilingsacc. to DIN 4102-2
Reduced Element Thickness from 51 mm
Fig. 99 Greater room height
k27219Advantages:
- Low thickness of elements
- Up to 10% less element weight
- The clear room height can be enlarged up to 14 mm or more space for installations in the ceiling cavity
Standard element
65
�51
Availa
ble
on
request
Customised element
* According to commentary on the 2000 version of the Sample Directive on Fireproofi ng Requirements for Line Systems [Musterleitungsanlagen-Richtlinie], this safety distance is required for all fi reproof suspended ceilings with fl ame contact from above.
Fig. 100 Finished fl oor height with standard/customised element
Element dimensions (length x width) differ depending on system → available on request
B4015.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 102 Classifi ed as independent, acc. to DIN 4102-2F30 from above and below
- Installation is possible in the most common plasterboard and Fermacell ceilings F30 from above and below
- Inspection hatch with plasterboard surface
- Maximum clear opening size 800 x 800 mm Other, smaller opening sizes are possible.
- Prefabrication by factory
- Concealed latching system
- Installation height from 90 mm Functional height from 140 mm
- With covering in the ceiling cavity
- Execution 100% free of mineral wool
Inspection hatch, type 3
k11283
Fireproof Ceilings with Sprinklers in the Ceiling Cavity
Sprinklers in the Ceiling Cavity above Fireproof Ceilings and Inspection Hatch for F30-Plasterboard Ceilings acc. to DIN 4102-2
k27221
In case of fi re, an independent fi reproof ceiling F30 from above and below is suffi cient in an essential corridor.
Additional sprinklers are required in rare cases. The ex-tinguishing water produced by the sprinkler system would load the independent fi reproof ceiling additionally, and might cause it to crash. Additional measures have to be taken for such cases.
Further information on this subject is available on re-quest.
Fig. 101
B4115.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Real Estate Property Example 1
F30-suspended ceiling in tunnel shape and roof shapeRefurbishment of the corridors in a hospital
Functional specifi cations
- Visually appealing suspended ceiling in vaulted ceiling or with roof shape
- Cable trays positioned low along the corridor walls
- Easily accessible ceiling cavity over ceiling elements that fold down on the end-side of the ceiling panels.
- Provision of certifi cation of property-related expert opinion based on existing building supervisory general certifi cates of inspection
F30 from above!
F30 from above!
Fig. 103
Fig. 104
Fig. 105
B4215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Functional specifi cations
- Installation of an F30-ceiling under a structurally non-load-bearing brick vaulted ceiling in the form of an F30-ceiling from above and below, and independent with plaster friezes on the side and centre inspection-friendly metal ceilings
- Fastening of the suspended ceiling on a wide-span girder construction supported on the bounding walls
- Precautions against mechanical services installations put in by the customer falling down in a fi re (because these are only attached with plastic anchors)
- Provision of certifi cation of property-related expert opinion based on existing building supervisory general certifi cates of inspection
Real Estate Property Example 2
F30-Corridor ceilingRefurbishment of hospital corridor
Brickvaulting
Anchors withoutfireproofingcertification
Bridging beam to assume the weightof the ceiling and the installationin case of a fire
Suspended ceiling F30 (requirement from above and below)
Solid wall
� F30
Corridor
Fig. 106
Fig. 107
Fig. 108
B4315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Functional specifi cations
- Dismantlement of existing F0-surface-mounted ceiling fi ttings and upgrading of existing F0-partition walls to F30-quality
- F30-Escape tunnel for refurbishment of existing building with customer-provided partition walls and hook-on type ceiling constructions made of metal
- Structural fi xation of the corridor partition walls ending at the height of the corridor ceiling
- Provision of certifi cation of property-related expert opinion based on existing building supervisory general certifi cates of inspection
Real Estate Property Example 3
F30-Escape tunnelEscape corridor within the scope of the refurbishment of a buildingFig. 109
Fig. 110
Fig. 111
B4415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Max. width of span
Fig. 112
Fireproof Ceiling LGKD F30-A acc. to DIN EN 1364-2
Plasterboard ceiling with free spanning system
- Tested acc. to DIN EN 1364-2 • EI 30 (a ↔ b)
- Corridor width up to 2900 mm without suspension, with free spanning system
- Overall height from approx. 87 mm, depending on the width of the span required
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (plasterboard walls)
- Built-in fi ttings possible: • Recessed light fi ttings • Surface-mounted light fi ttings • Speakers • Inspection hatch (a → b)
Patent pending
k21485
Fig. 113
k21538
100
Overa
llheig
ht
Type 1 free spanning system
B4515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Lay-on systemThe ceiling elements are individually removable.
- Classifi ed as independent, acc. to DIN 4102-2 • F90 from above
- Max. panel length • 2500 mm with F90 from above with a panel width of max. 397 mm
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (plasterboard walls) • Fascia
- Built-in fi ttings possible: • Recessed light fi ttings • Surface-mounted light fi ttings • Speakers • Ventilation valve
Fig. 115
Fig. 114
k10979
Type 2 lay-on type
Fig. 116 Abutment design
~3
86
Width of themetal ceiling element
Width of themetal ceiling element
B4615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 117 Corridor ceiling: free-spanning system from wall to wall
Fig. 118 Corridor ceiling with fascia
Fig. 120 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 119 Corridor/room ceiling with central suspension
k11117
k10904k10901
k11119
Panel length
Panel length
Frieze width Frieze widthPanel length
Panel length Panel length
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 2 lay-on type
B4715.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Panel length23
86
86
Panel length25Frieze width
86
20 Panel width
80
Fig. 126 Connection to plasterboard frieze design; frieze at same level
Fig. 124 End-side wall connection with shadow trim
Fig. 121 Wall connection to solid wall
Fig. 123 End-side wall connection with L-trim
k10451
k10832
k10452
k10829
k10456
20 Panel width
86
80
Panel length Panel length50
86
80
80
Fig. 125 Central suspension with hairline gap
Panel length
86
20
Fig. 122 Wall connection to plasterboard partition wall
k10455
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 2 lay-on type
B4815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 3 hook-on typeHook-on systemThe ceiling elements are individually removable.
- Classifi ed as independent, acc. to DIN 4102-2 • F90 from above
- Max. panel length • 2500 mm with F90 from above with a panel width of max. 397 mm
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (plasterboard walls) • Fascia
- Built-in fi ttings possible: • Recessed light fi ttings • Surface-mounted light fi ttings • Speakers • Ventilation valve
Fig. 128
Fig. 127
k12394
Fig. 129 Abutment design
~3
86
Width of themetal ceiling element
Width of themetal ceiling element
B4915.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 132 Corridor/room ceiling with central suspension Fig. 133 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 130 Corridor ceiling: free-spanning system from wall to wall
Fig. 131 Corridor ceiling with fascia
k12377
k26038 k26037
k12376
Panel length Panel length
Panel length Panel length Panel length Frieze widthFrieze width
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 3 hook-on type
B5015.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Plattenlänge max. 2500Plattenlänge max. 2500 ~20
86
180
Frieze width Panel length max. 2500~20
86
160
100 Panel length
Plasterboard wall in F90
83
15-27
86
Fig. 134 Wall connection to solid wall Fig. 135 Wall connection to plasterboard partition wall
Fig. 136 End-side wall connection with L-trim
k12489 k12711
k10451
Fig. 137 End-side wall connection with shadow trim
k10452
Plattenlänge15-27
86
~150
Fig. 138 Central suspension with shadow gap
k14278
Fig. 139 Connection to plasterboard frieze design Frieze at same level
k14275
20 Panel width
86
80
86
20 Panel width
80
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 3 hook-on type
B5115.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Drop-downfunction Sliding
function
This system is a protected and registered design.
Fig. 140
Fig. 141
Drop-down systemThese ceiling elements drop down individually and slide in the longitudinal direction of the corridor. Openings can be changed as desired.
- Classifi ed as independent, acc. to DIN 4102-2 • F90 from above
- Max. panel length • 2500 mm with F90 from above with a panel width of max. 397 mm
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (plasterboard walls) • Fascia
- Built-in fi ttings possible: • Recessed light fi ttings • Surface-mounted light fi ttings • Speakers • Ventilation valve
k21540
Fig. 142 Butt joint design
~3
86
Width of themetal ceiling element
Width of themetal ceiling element
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 5 hooked on with drop-and-slide function
B5215.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 145 Corridor/room ceiling with central suspension Fig. 146 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 143 Corridor ceiling: free-spanning system from wall to wall
Fig. 144 Corridor ceiling with fascia
k26044
k26046 k26045
k26043
Panel length Panel length
Panel length Panel length Frieze width Panel length Frieze width
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 5 hooked on with drop-and-slide function
B5315.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
~528Plasterboard frieze Panel length
86
14-44 28 ~5 Panel length
86
~186
145160
14-44 28 5 Panel length
~205
86
Fig. 147 Wall connection to solid wall Fig. 148 Wall connection to plasterboard partition wall
Fig. 149 End-side wall connection with L-trim
k15990 k24234
k10451
Fig. 150 End-side wall connection with shadow trim
k10452
Fig. 151 Central suspension with hairline gap
k24236
Fig. 152 Connection to plasterboard frieze design Frieze at same level
k24235
20 Panel width
86
80
86
20 Panel width
80
~5 ~528 28Panel length Panel length
86
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 5 hooked on with drop-and-slide function
B5415.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 153 Hook-on systemThe ceiling elements fold down and slide.
- Classifi ed as independent, acc. to DIN 4102-2 • F90 from above
- Max. panel length • 2500 mm with F90 from above with a panel width of max. 397 mm
- Wall connections are possible to: • Solid walls (concrete, masonry, lime-sand brick) • Light partition walls (plasterboard walls) • Fascia
- Built-in fi ttings possible: • Recessed light fi ttings • Surface-mounted light fi ttings • Speakers • Ventilation valve
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 8 fold-down type
Fig. 154 Fig. 155 Butt joint design
~3
86
Width of themetal ceiling element
Width of themetal ceiling element
k21540
B5515.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 158 Corridor/room ceiling with central suspension Fig. 159 Corridor/room ceiling, with plasterboard frieze on both sides
Fig. 156 Corridor ceiling: free-spanning system from wall to wall
Fig. 157 Corridor ceiling with fascia
k26040
k26042 k26041
k26039
Panel length Panel length
Panel length Panel length Panel lengthFrieze width Frieze width
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 8 fold-down type
B5615.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
Fig. 161 Wall connection to plasterboard partition wall
Fig. 162 End-side wall connection with L-trim
k22998
k10451
Fig. 163 End-side wall connection with shadow trim
k10452
Fig. 164 Central suspension with shadow gap
k26069
Fig. 165 Connection to plasterboard frieze design Frieze at same level
k21539
20 Panel width
86
80
86
20 Panel width
80
Fig. 160 Wall connection to solid wall
k21541
100
15-27
86
~200
Panel length
Plasterboard wall F90
83
15-27 Panel length 2500
86
~147
100
Panel length Panel length20
86
180
170
Panel length~20
86
Plasterboard frieze
Fireproof Ceiling LMD F90-A/AB acc. to DIN 4102-2
Type 8 fold-down type
B5715.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
12
0
Fireproof Ceiling LMD F90-AB in Accordance with DIN 4102-2
Type 9 lay-on typeFig. 166
Lay-on systemThe ceiling elements are individually removable.
- Classifi ed as independent, acc. to DIN 4102-2 • F90 from above • F90 from below
- Max. panel length • 2500 mm with F90 from above and below with a panel width of max. 300 mm
Fig. 167 Wall connection
k26087
Fig. 168 Butt joint design
k26086
Fig. 169 Plasterboard frieze fl ush with ceiling
k26088
k26085
120
~3300 300
12
0
B5815.0
Fireproof Ceiling SystemsSubject to technical changes also without notifi cation.
This document is the intellectual property of Lindner Holding KGaA Arnstorf.Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag
• General Guidelines Compliance with the following points is a prerequisite for
acceptable installation of Lindner fi reproof ceilings and F30-inspection hatches and so that their functioning and fi re protection can be guaranteed.
- DIN 4102, DIN 18 168-1 and 18 168-2 as well as DIN 18 202 all apply
- Execution of suffi cient ceiling cavity space- Climatic conditions during the installation
Temperature 20 °C ± 5 °C Relative humidity 40 % - 80 %
- The installation must only be carried out by qualifi ed per-sonnel.
- The installation guidelines for the various ceiling types must be taken into account and complied with according to the manufacturer‘s instructions.
- Only tested components with the appropriate classifi ca-tion may be used for the installation.
- Installation must be carried out according to the applica-ble building supervisory general certifi cates of inspec-tion.
• Fastening equipment The following must be taken into account for the fasten-
ings used for connections to walls and the structural ceil-ings:
- Use offi cially certifi ed anchors (both in terms of fi reproof-
ing and load-bearing capacity). Anchors must be set ex-actly according to regulations and/or certifi cation by the anchor manufacturer.
- Take the anchoring material base into account.- Allow for the weight of the ceiling.
• Storage- Do not store ceiling panels outdoors and protect them
against moisture (any moisture trapped by the protective sheeting might result in rust formation!)
- Remove the wrapper at the construction site immediate-ly after the ceiling material is delivered.
- Store with the arrows pointing upwards.
• Miscellaneous instructions:- During transport and installation, some of our metal fi re-
proof ceiling elements and panels are protected against soiling and damage by a self-adhesive protective fi lm. Do not remove this until just before the room is commis-
sioned. This protective fi lm must not come into contact with any solvents (thinner, glue, enamel, etc). Otherwise its ability to be removed may be substantially impaired!
- Standard surfaces are suitable for use with normal re-quirements in indoor areas, such as escape routes in hospitals, etc.
- In cases of special-purpose use, e.g. with solvent va-pours in production areas, approval for use must be ob-tained from the manufacturer.
Instructions for Installation and Use
Installation
How to useTo guarantee acceptable functioning of our ceilings, be sure to comply with the following points:
• Operation:- The suspended ceilings may only be operated by per-
sonnel instructed by the manufacturer.- Follow the user guidelines for the respective ceiling
type.- Two persons are always required to operate the sus-
pended ceiling.
Opening and closing the fi reproof ceilings:- Operation should only be carried out by qualifi ed per-
sonnel who have been instructed accordingly.- Restore the original condition as it was before opening
the ceiling. Important: Fire protection function- Use suitable tools
No alteration to existing ceiling systems may be carried out without prior approval by the manufacturer (such as additional subsequent recessed fi ttings, making lead-through openings for installation lines).
• ReproductionAll the building supervisory general certifi cates of inspec-tion and test certifi cates for these systems are the prop-erty of Lindner AG. It is not allowed to copy the ceiling systems following the certifi cations specifi ed and requires approval by Lindner AG.
• Exclusion of liabilityThese instructions come from experience acquired in ac-tual practice. Any liability by Lindner AG, however, must be excluded.