Fire Test Report ANSI/API Standard 607, 7th Edition, 2016 ISO 10497: 2010 API Standard 6FA, Third Edition, April 1999 Performed for MOGAS Industries, Inc. www.mogas.com 3 inch Class 900 C-Series Floating Ball Valve Valve Code: 3” 900 CA-1AS Project Number: 217143 Test Date: May 15, 2018 Performed by YARMOUTH RESEARCH AND TECHNOLOGY, LLC 434 Walnut Hill Road North Yarmouth, ME 04097 USA (207) 829-5359 [email protected] www.yarmouthresearch.com

Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

  • Upload
    others

  • View
    53

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

ISO 10497: 2010 API Standard 6FA, Third Edition, April 1999

Performed for

MOGAS Industries, Inc.

www.mogas.com

3 inch Class 900 C-Series Floating Ball Valve Valve Code: 3” 900 CA-1AS

Project Number: 217143 Test Date: May 15, 2018

Performed by

YARMOUTH RESEARCH AND TECHNOLOGY, LLC

434 Walnut Hill Road North Yarmouth, ME 04097 USA

(207) 829-5359 [email protected] www.yarmouthresearch.com

Page 2: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 2 of 17

Customer: MOGAS Industries, Inc. Date: 5/15/2018Specifications: ANSI/API Standard 607, Seventh Edition, 2016 ISO 10497: 2010

API Standard 6FA, Third Edition, April 1999 (R2008)Product Description: 3" Class 900 C-Series Floating Ball Valve

Valve Code: 3" 900 CA-1ASProject Number: 217143 0

Equipment Confirmed to be in Calibration to NIST Standards: Yes

Burn and Cool Down TestBurn Start Time: 14:45:00

Average Pressure During Burn: 1695 psigSeat Leak Rate During Burn: 0 ml/min

12801200 ml/min

External Leak Rate During Burn/Cool Down: 0.6 ml/min320300 ml/min

Amount of Time of Avg. Cal. Blocks > 650 deg. C: 21.3 minutesWere Test Conditions Within Compliance? Yes

Were the Valve Leakages Below the Allowables? Yes

Operational TestAverage Pressure During Test: 1662 psig

External Leak Rate After Operating: 0 ml/min80 ml/min

API 6FA 3rd Edition Allowable External Leak Rate: 600 ml/min

Was the Leakage Below the Allowables? Yes

Does Valve Pass or Fail the Test Standards? PASS

Certified by

Matthew J. Wasielewski, PEPresident and ManagerYarmouth Research and Technology, LLC

API 6FA 3rd Edition Allowable Seat Leak Rate:

API 6FA 3rd Edition Allowable External Leak Rate:

API 607 6th Edition Allowable External Leak Rate:

API 607 7th Edition Allowable Seat Leak Rate:

API 607 7th Edition Allowable External Leak Rate:

Page 3: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

YARMOUTH RESEARCH AND TECHNOLOGY, LLC

www.yarmouthresearch.com

Fire Test Specification and Revision: (ie. API 607 6th, API 6FA 3rd, etc) API 607 7th Edition/ ISO 10497 3rd Edition

Yarmouth Proposal/Quote Number: 217143BCustomer Purchase Order Number: 85660

Customer’s Contact Name: Samir LakhaniValve Manufacturer’s Name (used in test report

as specified): MOGAS Industries, Inc.

Company Web Address for Report Cover: www.mogas.com

Valve Manufacturer’s Address: 14330 East Hardy St.Houston, TX 77039

Did valve meet all required hydrostatic, leakage and other production pressure tests? Yes per API 598

Valve Description for Report Cover: 3" 900 CA-1AS Valve Product Code: C-Series

Valve Description Size: 3"

Pressure Rating/Class: 900Pressure Rating at 100F: 2220 (psig)

Type: C-Series Floating Ball ValveWeight: 309 (lbs)

Reduced or Full Bore: FullBody/Bonnet Material: A105

Trim Material: 410 Q&DTSeat Material: 410 Q&DT

Stem Seal Material: Stellite #3Body Seal Material: Inconel 600

Bolting Material: A193 Gr. B16 / A194 Gr. 7Is valve considered “Soft-Seated”? No (Metal Seated)

Valve MarkingsNameplate Information: 3" 900 CA-1AS

Casting Markings: N/AAssembly Drawing Number / Revision / Date of

Issue:F20267405 Rev 1Issue: 10/19/2017

Emailed (PDF) to Yarmouth: Date: 8/20/2017If valve is fitted with gearbox, state gearbox

manufacturer, model number and mechanical advantage:

Diamond Gear 18WG64mechanical advantage: 18

If valve is non-symmetric, state direction of flow for test: N/A

For double-seated valves, state maximum allowable cavity pressure: 2220 (psig)

Form Submission Date: 4/25/2018

Fire Test Information Sheet

PLEASE RETURN AS AN EXCEL DOCUMENT

Page 4: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

NOTES:1. ITEM NUMBER QUANTITIES MAY VARY- SEE BOM2. STEM PINS/KEYS 90 TO BALL PORT3. DIMENSIONS IN [ ] ARE MILLIMETERS

244 LBS65 LBS

309 LBS

VALVE:ACTUATOR:TOTAL:

APPROX STEEL WEIGHT111 KG

29 KG140 KG

2489.75

732.87

543

21.38

304

11.97

50

68

45718.00HW

1275.00TYP

1064.17

381

15.00

1656.50 914

36.00TYP

221087.00

602.38

TYP

532.07

TYP

PRESSURE END

18

06 51

24

13

19

252" NPT

TYP

49A

49B

TYP

FINAL ASSY I-A 3 SCH 40 BW X 2.87 900# TO DIAMOND 18WG64 W/ 18 HW

XXXXX

APPREVISION HISTORY

5432

76

LVL

(Unless noted otherwise)

= 125AA or better

Angles = ±.5

PER B.O.M.

XX-XX-XX

DATE

XXX= ±.005XX = ±.010

Tolerances

Material Drawn By Title

Sheet 1 of 1 SolidWorks Drawing

F20267405 1

Checked By

Approved By

Date

1:9Scale

Revision LevelDrawing Number

X = ±.060

REF DRAWING: 176998

ECO

XXXXX

LOCATIONA

SEVERE SERVICE BALL VALVES

soliver

PMI

10/19/2017

SPCONFIDENTIAL: This drawing and the information shown thereon are the exclusive property of MOGAS INDUSTRIES INC. and is not to be conveyed, copied, or reproduced in whole or in part without prior written consent from MOGAS INDUSTRIES.

FQMS-04-01-3 REV A

Page 5: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 5 of 17

0

100

200

300

400

500

600

700

800

900

1000

Tem

pera

ture

- C

Test Time - min:sec

Temperature verses Time Chart

Average Cal. Block

Average Flame

Page 6: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 6 of 17

0

200

400

600

800

1000

1200

1400

1600

1800

2000

Test

Pre

ssur

e-ps

ig

Test Time - min:sec

System Pressure verses Time Chart

System Pressure

Cavity Pressure

Page 7: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________ www.yarmouthresearch.com

Test Valve Prior to Burn

Valve Markings

Page 8: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________ www.yarmouthresearch.com

Test Valve During Burn

Page 9: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 9 of 17

Fire Test Information

Customer: MOGAS Industries, Inc. Date: 5/15/2018Product Code: 3" Class 900 C-Series Floating Ball Valve

Project Number: 217143

Fire Test Raw Data

Pressure Cavity Water Cal. Cal. Avg. Bonnet Body AverageTime (psig) Pressure Volume Block 1 Block 2 Cal Block Flame Flame Flame

(psig) (mls) Temp-C Temp-C Temp-C Temp-C Temp-C Temp-C14:45:00 1711 1715 40969 27 29 28 37 51 4414:45:15 1710 1723 40994 31 33 32 373 293 33314:45:30 1738 1726 40950 54 59 56 657 566 61214:45:45 1741 1736 40977 84 93 89 786 701 74314:46:00 1706 1732 40988 107 127 117 874 744 80914:46:15 1678 1683 40998 138 163 151 892 752 82214:46:30 1754 1753 40913 176 198 187 897 767 83214:46:45 1644 1655 40974 216 231 223 908 808 85814:47:00 1612 1607 41020 253 261 257 902 824 86314:47:15 1627 1637 40946 286 289 288 910 822 86614:47:30 1657 1663 41000 317 317 317 910 822 86614:47:45 1694 1701 40939 346 341 343 914 824 86914:48:00 1709 1703 40984 372 367 369 906 831 86814:48:15 1704 1719 40988 397 387 392 913 835 87414:48:30 1711 1707 40996 419 408 414 931 839 88514:48:45 1674 1676 40964 440 429 434 930 843 88714:49:00 1675 1681 40993 459 448 454 915 845 88014:49:15 1701 1701 40994 478 466 472 918 854 88614:49:30 1718 1723 41000 495 482 489 901 870 88614:49:45 1691 1697 41004 509 497 503 915 857 88614:50:00 1683 1687 40961 524 512 518 921 842 88114:50:15 1673 1691 41068 538 526 532 924 853 88814:50:30 1685 1692 40996 551 539 545 919 866 89314:50:45 1689 1697 40966 562 551 556 901 867 88414:51:00 1682 1700 40972 573 561 567 909 869 88914:51:15 1691 1704 41007 583 572 578 911 869 89014:51:30 1708 1715 40976 593 582 588 918 858 88814:51:45 1726 1727 40990 602 593 597 894 868 88114:52:00 1736 1746 40950 610 600 605 906 868 88714:52:15 1698 1705 40940 618 609 613 914 861 88814:52:30 1627 1650 40950 626 616 621 908 862 88514:52:45 1678 1680 41009 632 622 627 920 866 89314:53:00 1713 1706 40979 638 628 633 904 863 884

Page 10: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 10 of 17

Fire Test Data - continued14:53:15 1717 1705 40983 644 636 640 922 845 88314:53:30 1692 1697 40970 650 642 646 927 863 89514:53:45 1673 1689 40989 656 646 651 907 864 88514:54:00 1679 1688 40979 661 653 657 913 856 88514:54:15 1666 1686 40955 669 657 663 902 862 88214:54:30 1688 1683 40984 668 661 664 922 853 88814:54:45 1675 1681 40983 672 665 668 906 862 88414:55:00 1678 1678 40961 678 671 674 887 878 88314:55:15 1702 1688 40892 682 675 679 869 882 87614:55:30 1698 1691 40942 683 679 681 912 879 89614:55:45 1678 1699 40971 691 683 687 908 878 89314:56:00 1693 1706 40997 691 685 688 921 871 89614:56:15 1716 1723 40989 696 686 691 899 878 88814:56:30 1738 1743 40963 698 693 696 901 875 88814:56:45 1740 1749 40969 702 694 698 877 879 87814:57:00 1745 1770 40960 698 696 697 901 876 88814:57:15 1728 1721 40976 701 698 699 899 876 88714:57:30 1695 1707 40990 705 701 703 887 868 87714:57:45 1698 1704 40977 711 703 707 878 889 88314:58:00 1697 1679 40900 708 704 706 885 882 88314:58:15 1679 1687 40961 713 708 711 873 873 87314:58:30 1693 1691 40960 712 709 711 869 878 87414:58:45 1684 1704 41011 714 712 713 879 876 87814:59:00 1716 1711 40970 712 713 713 849 884 86714:59:15 1709 1721 40919 719 714 717 858 883 87014:59:30 1749 1736 41007 720 718 719 861 882 87114:59:45 1629 1635 40991 722 718 720 874 876 87515:00:00 1668 1686 41052 722 719 720 851 868 85915:00:15 1732 1738 40928 723 720 721 894 874 88415:00:30 1736 1752 40973 724 721 723 897 871 88415:00:45 1656 1650 40999 723 723 723 889 876 88315:01:00 1655 1644 40957 727 724 726 856 879 86815:01:15 1688 1699 40977 724 723 724 881 886 88315:01:30 1693 1695 40975 725 726 725 864 866 86515:01:45 1668 1666 41027 725 726 726 876 889 88315:02:00 1633 1659 40953 726 727 726 852 871 86115:02:15 1615 1629 40993 726 727 726 871 886 87815:02:30 1614 1619 40994 727 728 727 868 889 87915:02:45 1652 1653 40966 727 729 728 872 887 88015:03:00 1733 1754 40934 728 729 729 849 872 86115:03:15 1674 1671 40965 728 729 728 849 872 86015:03:30 1673 1684 40964 728 728 728 892 872 88215:03:45 1670 1666 40988 728 731 729 894 872 883

Page 11: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 11 of 17

Fire Test Data - continued15:04:00 1642 1642 41021 729 731 730 866 893 88015:04:15 1647 1651 41024 729 732 731 836 888 86215:04:30 1660 1666 41000 728 732 730 819 875 84715:04:45 1678 1677 40966 729 732 731 822 877 84915:05:00 1683 1687 40982 729 732 731 808 889 84815:05:15 1651 1640 40984 729 731 730 810 883 84615:05:30 1621 1635 40989 728 732 730 854 888 87115:05:45 1635 1643 40995 728 731 730 846 888 86715:06:00 1650 1660 40955 729 730 729 827 883 85515:06:15 1671 1663 40999 729 732 731 820 896 85815:06:30 1676 1678 41005 729 733 731 842 886 86415:06:45 1683 1686 41000 729 732 731 794 873 83315:07:00 1695 1700 41012 728 733 731 798 878 83815:07:15 1707 1717 40932 728 732 730 847 888 86815:07:30 1725 1727 40966 729 734 732 885 903 89415:07:45 1681 1688 40965 731 734 732 880 891 88615:08:00 1654 1666 40962 731 735 733 839 866 85215:08:15 1681 1701 40929 731 736 733 796 881 83815:08:30 1694 1714 40897 729 736 733 809 884 84715:08:45 1660 1672 40976 728 736 732 816 897 85615:09:00 1634 1640 40991 728 734 731 882 887 88415:09:15 1611 1611 40984 728 736 732 831 872 85115:09:30 1678 1690 40995 730 736 733 836 875 85515:09:45 1681 1691 40980 730 736 733 827 868 84715:10:00 1642 1654 40926 730 736 733 848 888 86815:10:15 1688 1693 40989 731 736 733 818 886 85215:10:30 1704 1711 40981 731 736 734 828 860 84415:10:45 1720 1726 40952 731 738 735 841 888 86415:11:00 1726 1735 40969 732 737 734 845 873 85915:11:15 1682 1687 40991 732 737 734 867 885 87615:11:30 1637 1647 40962 732 736 734 853 888 87115:11:45 1619 1619 40980 731 738 735 793 880 83615:12:00 1647 1652 41000 731 736 733 804 857 83115:12:15 1690 1700 40981 731 736 734 795 857 82615:12:30 1742 1749 40998 729 739 734 836 906 87115:12:45 1734 1737 40951 730 737 733 811 884 84815:13:00 1668 1675 40988 729 738 733 852 902 87715:13:15 1612 1629 40976 729 738 734 847 897 87215:13:30 1582 1581 40988 728 737 733 847 898 87315:13:45 1626 1618 40937 727 739 733 835 891 86315:14:00 1702 1698 40984 727 737 732 833 889 86115:14:15 1755 1763 41000 727 738 733 834 881 85815:14:30 1637 1639 41013 726 738 732 779 872 826

Page 12: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 12 of 17

Fire Test Data - continued15:14:45 1647 1658 41020 726 741 733 803 836 81915:15:00 1666 1671 41002 724 741 732 858 886 87215:15:15 1647 1648 41014 723 739 731 663 666 66415:15:30 1609 1622 40938 714 733 724 476 487 48215:15:45 1554 1557 40978 700 720 710 384 392 38815:16:00 1486 1503 40985 675 696 685 82 70 7615:16:15 1565 1530 40912 640 642 641 54 51 5315:16:30 1711 1707 40905 610 567 588 46 54 5015:16:45 1719 1719 40885 580 455 518 43 46 4515:17:00 1700 1706 40841 544 332 438 47 51 4915:17:15 1701 1707 40825 498 225 361 43 58 5115:17:30 1493 1514 40756 438 152 295 56 56 5615:17:45 1523 1521 40760 353 106 229 57 55 5615:18:00 1787 1779 40713 258 81 169 56 52 5415:18:15 1704 1706 40739 176 65 120 52 45 4815:18:30 1716 1696 40745 121 54 88 48 40 4415:18:45 1724 1725 40746 92 46 69 42 35 3815:19:00 1715 1717 40696 75 41 58 36 32 3415:19:15 1719 1718 40677 64 37 51 29 29 2915:19:30 1717 1714 40694 56 34 45 26 27 2615:19:45 1670 1669 40639 52 31 41 22 26 2415:20:00 1726 1710 40630 45 29 37 18 23 2015:20:15 1716 1702 40641 39 28 34 17 21 1915:20:30 1723 1696 40638 38 26 32 16 18 1715:20:45 1720 1697 40600 32 24 28 17 20 1915:21:00 1563 1557 40588 32 23 27 17 20 1915:21:15 1494 1456 40598 29 23 26 15 19 1715:21:30 1693 1681 40570 29 21 25 16 17 1615:21:45 1674 1659 40553 27 20 23 13 15 1415:22:00 1674 1650 40613 26 19 23 14 17 1615:22:15 1666 1644 40565 27 21 24 12 16 1415:22:30 1664 1646 40560 26 19 23 13 15 1415:22:45 1670 1646 40528 26 18 22 22 19 2115:23:00 1616 1572 40509 26 21 24 23 18 2115:23:15 1602 1584 40555 29 21 25 10 15 1315:23:30 1546 1539 40513 23 21 22 11 13 1215:23:45 1483 1432 40135 23 19 21 10 12 1115:24:00 1610 1609 40239 21 16 18 8 11 915:24:15 1641 1642 40217 20 18 19 10 10 1015:24:30 1649 1645 40207 18 17 18 9 12 1115:24:45 1652 1649 40183 19 18 18 8 10 915:25:00 1659 1652 40194 17 18 18 8 17 13

Page 13: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 13 of 17

Leakage Summary for Burn and Cool Down Periods

All pressure transducers and thermocouples are in calibration per YRT's QA program.Seat leakages were collected manually. External leakage was collected electronically.

Total Through Seat Leakage Collected Over 30 Minute Duration: 0 mlsAverage Leak Rate Over 30 Minute Duration: 0 ml/min

API 607 7th Edition Allowable Seat Leak Rate: 1280API 6FA 3rd Edition Allowable Seat Leak Rate: 1200 ml/min

Total Through Seat Leakage Collected Over 10 Minute Cool Down: 0 mls

Total Water Volume Lost Over 40 Minute Burn and Cool Down: 775 mlsWater Collected in System Relief Valve: 750 mls

Calculated External Leakage During 40 Minute Duration: 25 mlsAverage External Leak Rate Over 40 Minute Duration: 0.6 ml/min

API 607 7th Edition Allowable External Leak Rate: 320API 6FA 3rd Edition Allowable External Leak Rate: 300 ml/min

Were the Valve Leakages Below the Allowables? Yes

Page 14: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 14 of 17

Summary of Test Parameters During Burn and Cool Down Periods

Amount of Time Pressure Dropped Below 50%: 0.0 minutesMaximum Allowable Low Pressure Time: 2.0 minutes

Maximum Pressure During Burn/Cool Down: 1787 psigAverage Pressure During Burn/Cool Down: 1674 psig

Minimum Pressure During Burn/Cool Down: 1483 psig

Amount of Time of Avg. Cal Block > 650 deg.C: 21.3 minutesMinimum Allowable Time at Temperature: 15.0 minutes

Maximum Avg Cal Block Temperature: 735 deg. CAverage Cal Block Temperature: 518 deg. C

Lowest Avg Cal. Block Temperature: 17.5 deg. C

Maximum Body Flame Temperature During Burn: 906 deg. CAverage Body Flame Temperature During Burn: 855 deg. C

Maximum Bonnet Flame Temperature During Burn: 931 deg. CAverage Bonnet Flame Temperature During Burn: 859 deg. C

Average of Both Flame Temperatures During Burn: 857 deg. C

Notes

Were Test Conditions Within Compliance? Yes

Page 15: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 15 of 17

Post-Burn Seat Test Information

Customer: MOGAS Industries, Inc. Date: 5/15/2018Product Code: 3" Class 900 C-Series Floating Ball Valve

Project Number: 217143

This test is not required for this pressure class.

Page 16: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 16 of 17

Post-Burn Seat Test Information

Customer: MOGAS Industries, Inc. Date: 5/15/2018Product Code: 3" Class 900 C-Series Floating Ball Valve

Project Number: 217143

This test is not required for this pressure class.

Page 17: Fire Test Report ANSI/API Standard 607, 7th Edition, 2016

Yarmouth Research and Technology, LLC

________________________________www.yarmouthresearch.com Page 17 of 17

Operational Test Information

Customer: MOGAS Industries, Inc. Date: 5/15/2018Product Code: 3" Class 900 C-Series Floating Ball Valve

Project Number: 217143

Test Data after Operating Valve

Pressure Cal BlockTime (psig) Temp - C

15:29:55 1661 2015:30:10 1652 2015:30:25 1653 1815:30:40 1666 1915:30:55 1657 1715:31:10 1666 2015:31:25 1669 1815:31:40 1667 1915:31:55 1667 2115:32:10 1669 2015:32:25 1661 2115:32:40 1660 2115:32:55 1677 1915:33:10 1661 1815:33:25 1651 2115:33:40 1679 1915:33:55 1649 2115:34:10 1663 2215:34:25 1662 2115:34:40 1658 2115:34:55 1659 21

Leakages were collected manually.

Total External Leakage Collected Over 5 Minute Duration: 0 mlsAverage Leak Rate Over 5 Minute Duration: 0 ml/min

80 ml/minAPI 6FA 3rd Edition Allowable External Leak Rate: 600 ml/min

Was the Valve Leakage Below the Allowable? Yes

API 607 7th Edition Allowable External Leak Rate: