Fire Fighting_abandon Ship Drill Checklist(1)

Embed Size (px)

Citation preview

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    1/9

    1 / 9

    Fire Fighting/Abandon Ship Drill Checklist

    Ship Name

    IMO Number

    Confirmed by

    (Name/Signature)

    Date

    Total number of

    crew attended

    2009.09.16/Rev.1

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    2/9

    Fire Fighting/Abandon Ship Drill Checklist

    2 / 9

    No. Check Point Result

    Fire Drill - 1 / (Stage 1 / Reporting Bridge of fire)

    1

    // ? ( )

    Has the Bridge been informed of the fire(location/size/kind)? Initial caller Rank ( )YES / NO / NA

    ( )

    1) /// . 2) .

    * : /

    * : A' DECK 'B, ( / / .)

    (Note)

    1) The auditor needs to have a discussion with the Captain about the location, size, kind and time of the fire 2) The auditor may Select

    anyone from the crew as an initial caller to observe how to report it.* Choosing an initial caller: Choosing a crew member who is most likely connected to the designated fire source in his job role and the time

    as to when the fire started.

    * Example: A' DECK Galley, Class 'B, Medium fire (Small / Medium / Large)

    2 ?

    Is Fire-Signal correct with the one on the Muster List?YES / NO / NA

    3 / / ?

    Does Ship's alarm announcement contain the information about the fire(location / size / kind)?YES / NO / NA

    Fire Drill - 2 / (Stage 2 / Initial actions to be taken by an initial caller)

    4

    () ?

    Has the Proper extinguisher(s) been used?YES / NO / NA

    ( ) .

    (Note) In case of a medium or large fire the initial caller shall evacuate the area by shutting off the appropriate local ventilation and then go to

    the Muster Station.

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    3/9

    Fire Fighting/Abandon Ship Drill Checklist

    3 / 9

    5

    ?

    Has the Local ventilation been shut by the initial caller?YES / NO / NA

    ( ) :

    (Note) Example: In case of a fire in Galley, shut the exhaust duct and entry door.

    Fire Drill - 3 / (Stage 3 / Mustering and preparation )

    6

    ?

    Has the Roll call been reported to the Bridge?YES / NO / NA

    7

    ?

    Has the crews taken out their personal effects at the Muster Station?YES / NO / NA

    ( )

    1) .2) . , .

    * 1: 5

    * 2: Fire Control Plan ( ) .

    (Note)

    1) In case of a fire, life jackets and immersion suits shall be carried out as a personal effects.

    2) A fireman's outfit shall be carried and worn. BA pressure shall be checked and a mask is not needed to be worn at this stage.

    * Recommendation 1: 5 minutes is needed from the ringing Fire-Signal to complete this stage.

    * Recommendation 2: Fire Control Plan is used by the Bridge or Leader of the scene.

    8

    ?

    Has the Main Fire pump or Emergency fire pump been started?

    YES / NO / NA

    ( ) . :

    (Note) The appropriate fire pump shall be used depending on the location of the fire.

    Example: Emergency Fire Pump in case of an engine room fire.

    9 ?

    Has the Electrical supplies and lighting been turned off and has the Fuel oil been isolated?YES / NO / NA

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    4/9

    Fire Fighting/Abandon Ship Drill Checklist

    4 / 9

    10

    Has the Ventilation been closed?YES / NO / NA

    .

    (Note) The ventilators of the fire zone, which were left opened by the initial caller due to lack of time or a systemic matter, shall be

    properly closed.

    Fire Drill - 4 / (Stage 4 / Entry into the fire zone and fire-fighting)

    11

    ?

    (BA() / / / / )

    Has the following been checked and reported to the Bridge before the Fire Team entered into the fire zone and Reported it

    to the Bridge (BA pressure / Time of entry / Name / Mask secure and Safety Lanterns are all good condition.)

    YES / NO / NA

    ( ) 1) 2) .

    (Note) 1) Entry into the fire zone shall be permitted only by persons who are wearing the fireman's outfit.

    2) Checking and recording the above particulars by the bridge team or the scene team before entry into the fire zone.

    12

    ?

    Has the Entrance Door been checked?YES / NO / NA

    ( ) Door : 2

    ( )

    ,

    .

    (Note) Door Check before entry into the fire zone: At least two persons,

    one is the main hose man and the other is the back up, shall be allowed

    to enter into the fire zone as a fire fighting team.

    The back up approaches to the entry door and feels the surface heat

    with his hand. If he dose not feel any heat, he shall open the door

    a little and let the main hose man spray water inside.

    13 ?

    Is the fire hose the proper length?YES / NO / NA

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    5/9

    Fire Fighting/Abandon Ship Drill Checklist

    5 / 9

    ( ) 1) 2 2) .

    (Note) 1) When the fire zone is located out of range of one hose, the connection of two fire hoses shall enable it to be ready to be used to

    fight the fire.

    2) Additional fire hose(s) shall be ready for boundary cooling.

    14

    , ?

    Has the Boundary checking in progress been reported to the Bridge and has boundary cooling started?YES / NO / NA

    ( ) 1) 2 . 2) .

    (Note) 1) At least two persons for a fire hose shall be engaged as one team. 2) Don't use water in real but demonstrate only.

    Fire Drill - 5 / (Stage 5 / Rescue operation)

    15

    // ?

    Has the Bridge been informed of the injured.(Name/location/status)?YES / NO / NA

    ( ) 1 , .

    (Note) An incident of an injured person shall be included as part of the drill scenario and the location of the incident can be decided by

    the Captain.

    16

    ?

    Has The injured person been transferred quickly to a safe location?YES / NO / NA

    ( )

    1) . 2) .

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    6/9

    Fire Fighting/Abandon Ship Drill Checklist

    6 / 9

    * 1: (// )

    * 2: ( , , , , cleaning ) ---

    .

    (Note)

    1) The auditor can confirm that the injured person(s) has been quickly carried to a safe place by means of proper equipment such as a

    stretcher, a portable winch. 2) The auditor confirm that the injured person(s) has been consistently monitored by the rescue team and

    been reported to the Bridge.

    * Recommendation 1: Checking first-Aid(Treatment of Unconsciousness/Fractures/Burns)

    * Recommendation 2: Checking the personal effects of the rescue team(Stretcher, First Aid Kit, Oxygen Respiratory Devices, Blankets,

    Cleaning water, Vinyl wraps) --- Personnel effects shall be considerably reasonable depending on the circumstances.

    Fire Drill - 6 / (Stage 6 / Use of a Fixed Fire Extinguishing System)

    17

    ?( )

    Has the Ventilation been closed for use of the fixed fire extinguishing system?(If applicable)

    YES / NO / NA

    ( ) . :

    (Note) Shutting off the overall ventilation in a fire zone before using the Fixed Fire-extinguishing System. Example: All doors to the engine room

    18

    ?

    Has the Roll call been reported to the Bridge?YES / NO / NA

    ( ) .

    (Note) All crew shall be evacuated from the fire zone before using the Fixed Fire-extinguishing System and going to the Muster Station.

    Abandon Ship Drill - 1 / (Stage 1 / Preparation for Abandoning Ship)

    19 ?

    Is the Abandon Ship Signal correct with the one described on the Muster List?YES / NO / NA

    20 ?

    Has the Roll call been reported to the Bridge?YES / NO / NA

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    7/9

    Fire Fighting/Abandon Ship Drill Checklist

    7 / 9

    Abandon Ship Drill - 2 / (Stage 2 / Lowering)

    21

    ?

    Has the Lifeboat been lowered above the water level within the compulsory time limit?YES / NO / NA

    ( )

    1) ( 10, 30, 2 5 )

    2)

    3) Lashing wire, Painter, Bowsing tackle(Open type), Hand break

    4) Free Fall Type ( )

    (Note)

    1) A lifeboat is lowered up to above the water without anyone on board the lifeboat if possible.(Cargo Ship: 10 minutes / Passenger Ship 30

    minutes / Rescue boat haas limit of only 5 minutes by two persons.)

    2) Verifying that the boat has been lowered by the personnel having duties on the Muster List.

    3) Checking operations of unlashing wire, Painter, Bowsing tackle(Open Type), Hand break.

    4) Checking the simulation test(by the maker's manual) only in case of Free Fall Type.

    Abandon Ship Drill - 3 / ( ) (Stage 3 / Checking Lifeboat(Rescue Boat) Engine

    and miscellaneous)

    22

    () ? ( )

    Is Lifeboat engine working well? Engine starter's rank ( )YES / NO / NA

    ( )

    1) /, Rudder, Tiler

    2) 3) 1 , 1

    .

    (Note)

    1) Checking the lifeboat engine test(Ahead/Astern), Rudder and Tiler.

    2) Checking the rescue boat engine test. 3) Selecting two crew members and let them start the engine: One is a person in charge and the

    other is one who has the least amount of onboard experience or is the person least familiar with the equipment.

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    8/9

    Fire Fighting/Abandon Ship Drill Checklist

    8 / 9

    23 / / / / ?

    Is the donning of life jackets and their accessories such as Whistles, Lights and Lines(knots) all in good condition?YES / NO / NA

    24

    ?

    Has the crew taken out their personnel effects as set in the Muster List?YES / NO / NA

    ( )

    1) , .

    , SART .

    2) SART, , Two-way radio, () , SART SART

    . : , / ,

    (Note)

    1) No one can go into the accommodations to bring out their personal effects in case of fire in accommodations. In case of a fire in a

    place other than the accommodations, the crew can bring out their personal effects for abandoning the ship. To verify a crew's familiarity

    with SART operation in case of fire in the accommodations, please check it out as well.

    2) Checking personal effects (SART, Crew list, Two-way radio, Immersion suits, life jackets and to see if a person in charge of SART knows

    about it.) (Example: How to rig it to the lifeboat, how/when to use it, how long the battery can be used for?)

    25 ?

    Is the Em'cy light working?YES / NO / NA

    26

    / ?

    Has the operation description of the lifeboat(s) and rafts been posted and is visible?YES / NO / NA

    ( )

    (Note) Checking the posting condition and position of operation description.

    Miscellaneous - (Operation familiarity with emergency equipment)

    27

    - (: /: )YES / NO / NA

  • 7/31/2019 Fire Fighting_abandon Ship Drill Checklist(1)

    9/9

    Fire Fighting/Abandon Ship Drill Checklist

    9 / 9

    - (: /: )

    - (: /: )

    How to operate the emergency equipment

    - Fixed fire-extinguishing system (Rank: /Rank: )

    - Emergency Generator (Rank: /Rank: )

    - Emergency Fire-Pump(Rank: /Rank: )

    * Select two crew members : One from PIC on the Muster List and the other person who has the least amount of

    onboard experience or is the person least familiar with the equipment.

    ( )

    1)

    -Pilot Bottle CO2 30 -

    - CO2

    2) ( )

    - -

    (Note)

    1) Fixed Fire-extinguishing System

    - The auditor can confirm that a crew can explain the 30 second delay mechanism of the Pilot bottle CO2, and confirm that a crew can

    explain the manual operation method, as well as confirm that a crew can explain how to separate the drenching sections for the system.

    2) In addition, the auditor can confirm that a crew can explain how to operate the Emergency Generator(manual operation) and the

    Emergency Fire Pump.

    - There must be no leakage from any part of the Emergency Fire Pump. Furthermore, proper water pressure can be observed from two hoses

    at the same time.