    Connection

    point

    C. Wind rails and Loads at the Anchoring Points

    1. Cabin Wind Loads

    In the most extreme (acceptable) wind

    conditions and in case of unbalancedloading, the cabin imposes the

    following maximum forces on each

    rail, at each connection point

    Fx=253 Kgf

    Fy=357 Kgf

    Fz=100 Kgf

    Note: Since at the ICC project the

    cabin pathway is the niche, we expect

    much lower forces, if any.

    2. Reactions for sub anchoring installation:

    Building reactions under each side of the winch (there are two anchoring point on

    each side):

    Vertical reaction: Rz = 65 [KN]

    Horizontal reaction in machine direction: Rx = 5 [KN]

    Horizontal reaction in perpendicular direction: Ry = 5 [KN]

    Note: the anchoring points and dimensions can be adjusted accordance with

    building requirements.