  • 8/13/2019 Fire Code and Plumbing Code

    1/54

    RA9514FIRE CODE

    OF THE PHILIPPINESPrepared by:Diaz, Anthony Oblinada, Marjorie

    Lorena, Martin Salvador, Mark BoninMasbate, Darren Seculles, France Marie

  • 8/13/2019 Fire Code and Plumbing Code

    2/54

    DIVISION 5

    Means of Egress

  • 8/13/2019 Fire Code and Plumbing Code

    3/54

    Definition of Means of Egress

    It refers to the ability to exit the structure, primarily in the event of an

    emergency, such as fire.

    Three Parts of Means of Egress

    The path of travel to an exit

    The Exit itself

    The exit discharge (the path to a safe area outside)

    DIVISION 5. MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    4/54

    SECTION 10.2.5.2 GENERAL PROVISIONS

    Minimum Width

    The width of any means of egress shall not be

    less than 915 mm

    Number of Means of Egress

    balcony, mezzanine, storey or portion thereof shall not be less than 2 501-999 persons: shall not be less than 3

    1000 or more persons: shall not be less than 4

    Elevator lobbies shall have access to at least one exit. Such exit

    access shall not require the use of a key, a tool, special knowledge,

    or special effort.

    DIVISION 5. MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    5/54

  • 8/13/2019 Fire Code and Plumbing Code

    6/54

    TO COMPUTE FIRE EXIT WIDTH

  • 8/13/2019 Fire Code and Plumbing Code

    7/54

    SECTION 10.2.5.2 GENERAL PROVISIONS

    Arrangement of Exit

    Exits shall be accessible at all times.

    DIVISION 5. MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    8/54

    In buildings protected throughout by an approved

    supervised automatic sprinkler system, the minimum

    separation distance between two exits or exit access shall

    not be less than one-third (1/3) the length of the maximum

    overall diagonal dimension of the building

  • 8/13/2019 Fire Code and Plumbing Code

    9/54

  • 8/13/2019 Fire Code and Plumbing Code

    10/54

    HEADROOM

    Minimum headroom of a means of egress is 2 meters in

    height, nor any part of the ceiling must be lower than 2

    meters in height

  • 8/13/2019 Fire Code and Plumbing Code

    11/54

  • 8/13/2019 Fire Code and Plumbing Code

    12/54

    SECTION 10.2.5.2 GENERAL PROVISIONS

    Exterior Ways of Exit Access

    An exterior way of exit access shall be arranged

    so that there are no dead-ends in excess of 6 min length.

    A permanent, reasonably straight path of travel

    must be maintained over the required exterior

    way of access.Access to an exit may be by means of any

    exterior balcony, porch or gallery

    DIVISION 5. MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    13/54

    SECTION 10.2.5.7 RAMPS

    DIVISION 5. MEANS OF EGRESS

    Minimum width, clear of all obstructions 1.12 m

    Maximum rise for a single ramp run 0.76 m

    Maximum slope 1:12

  • 8/13/2019 Fire Code and Plumbing Code

    14/54

    SECTION 10.2.5.4 STAIRS

  • 8/13/2019 Fire Code and Plumbing Code

    15/54

  • 8/13/2019 Fire Code and Plumbing Code

    16/54

    Where the total occupant load of all storeys

    served by the stair is fewer than 50, the

    minimum width clear of all obstructions

    shall be nine hundred fifteen millimeters

    (915 mm)

  • 8/13/2019 Fire Code and Plumbing Code

    17/54

    CURVED STAIRS

    Curved stairs shall be permitted as a component in a

    means of egress, provided that the depth of tread is not

    less than two hundred eighty millimeters (280 mm) at a

    point three hundred five millimeters (305 mm) from the

    narrowest end of the tread

  • 8/13/2019 Fire Code and Plumbing Code

    18/54

    SPIRAL STAIRS

    Riser heights shall not exceed one hundred eighty

    millimeters (180 mm).

    The stairway shall have a tread depth of not less than two

    hundred eighty millimeters (280 mm)

    The turn of the stairway shall be such that the outer

    handrail is at the right side of descending users.

    DIVISION 5 MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    19/54

    SECTION 10.2.5.10 FIRE ESCAPE STAIRS

    DIVISION 5. MEANS OF EGRESS

  • 8/13/2019 Fire Code and Plumbing Code

    20/54

  • 8/13/2019 Fire Code and Plumbing Code

    21/54

    Maximum height between landings 3.66 m

    Minimum headroom 2.00 m

  • 8/13/2019 Fire Code and Plumbing Code

    22/54

    DIVISION 8

    Places of Assembly

    DIVISION 8 PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    23/54

    SECTION 10.2.8.1 OCCUPANT LOAD

    area of concentrated use without fixed seats such as an auditorium,

    place of worship, dance floor, and lodge room:

    0.65 square meter per person

    area of less concentrated use such as conference room, dining room,

    drinking establishment, exhibit room, gymnasium, or lounge:1.4 square meters per person

    standing room or waiting space:

    0.28 square meter per person

    DIVISION 8. PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    24/54

    DIVISION 8 PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    25/54

    SECTION 10.2.8.2 EXIT DETAILS

    Minimum Corridor Width

    50 or more persons: shall not be less than 1.12 meters

    Travel Distance to Exits

    not protected by sprinkler system: maximum of 46 meters

    protected by sprinkler system: maximum of 61 meters

    DIVISION 8. PLACE OF ASSEMBLY

    DIVISION 8 PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    26/54

    SECTION 10.2.8.2 EXIT DETAILS

    Seating, Aisles and Railings

    Rows of seats from back to back shall be not less than 83 cm.

    There shall be a space of not less than 30 cm from the back of one

    seat and the front of the seat immediately behind it.

    The fasciae of boxes, balconies and galleries shall have substantialrailings not less than 66 cm high above the floor.

    DIVISION 8. PLACE OF ASSEMBLY

    DIVISION 8 PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    27/54

    SECTION 10.2.8.2 EXIT DETAILS

    Seating, Aisles and Railings

    Rows of seats between aisles shall have not more than 14 seats.

    Rows of seats opening onto an aisle at one side only shall have not

    more than 7 seats.

    60 seats or more: shall be not less than 915 mm when servingseats on one side only and not less than 122 cm when serving

    seats on both sides

    DIVISION 8. PLACE OF ASSEMBLY

    DIVISION 8 PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    28/54

    SECTION 10.2.8.2 EXIT DETAILS

    Seating, Aisles and Railings

    The gradient of sloping aisles shall not exceed 12.5%.

    Steps shall not be placed in aisles unless the gradient exceeds

    12.5%.

    DIVISION 8. PLACE OF ASSEMBLY

  • 8/13/2019 Fire Code and Plumbing Code

    29/54

    DIVISION 12

    Residential Occupancies

    DIVISION 12 RESIDENTIAL OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    30/54

    SECTION 10.2.12.3 HOTELS AND DORMITORIES

    Classification

    Hotels

    Dormitories

    Apartment Buildings

    Lodging or Rooming Houses Single-and-Two Family Dwellings

    Occupant Load

    1 person per 18.6 sq.m.

    Maximum probable population

    DIVISION 12. RESIDENTIAL OCCUPANCIES

    DIVISION 12 RESIDENTIAL OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    31/54

    SECTION 10.2.12.3 HOTELS AND DORMITORIES

    Types of Exits

    Doors

    Stairs and smoke-proofed enclosures

    Ramps

    Horizontal exits

    Exit Details

    Any room having a capacity of less than 50 persons with an outside

    door at street or ground level may have such outside door as a single

    exit provided that no part of the room or area is more than 15.25 m

    from the door measured along the natural path of travel.

    DIVISION 12. RESIDENTIAL OCCUPANCIES

    DIVISION 12. RESIDENTIAL OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    32/54

    SECTION 10.2.12.3 HOTELS AND DORMITORIES

    Minimum Corridor

    Width

    112 cm.

    For a capacity of not

    more than 50 personsshall not be less than 91

    cm.

    Number of Exits

    Not less than 2 exits

    DIVISION 12. RESIDENTIAL OCCUPANCIES

    DIVISION 12. RESIDENTIAL OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    33/54

    SECTION 10.2.12.3 HOTELS AND DORMITORIES

    Maintenance of Exits

    No residential occupancy shall have its means of egress pass through

    any non-residential occupancy in the same building

    No guest room or guest suite shall be located above or below a non-

    residential occupancy

    DIVISION 12. RESIDENTIAL OCCUPANCIES

    DIVISION 12. RESIDENTIAL OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    34/54

    SECTION 10.2.12.3 HOTELS AND DORMITORIES

    Access and Arrangement of

    Exits

    Dead end at corridords shall not

    exceed 6 meters

    Exits shall be accessible at leasttwo different directions

    S O S OCCU C S

  • 8/13/2019 Fire Code and Plumbing Code

    35/54

    DIVISION 13

    Mercantile Occupancies

    DIVISION 13. MERCANTILE OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    36/54

    SECTION 10.2.13.2 EXIT DETAILS

    Number of Exits

    Not less than two separate exits shall be provided on every storey.

    Not less than two separate exits shall be accessible from every part of

    every storey. A single means of egress shall be permitted in a Class C mercantile

    occupancy, provided that the travel distance to the exit or to a mall

    does not exceed 23 m. If provided with sprinkler system, it may be

    extended to 30 m.

  • 8/13/2019 Fire Code and Plumbing Code

    37/54

    DIVISION 13. MERCANTILE OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    38/54

    SECTION 10.2.13.1 GENERAL REQUIREMENTS

    Sub-classification of Occupancy

    Class A. AII stores having gross area of 2,787 sqm or more, or

    utilizing more than 3 floor levels for sales purposes.

    Class B. All stores of less than 2,787 sqm aggregate area, but over287 sqm.

    Class C. All stores of 278 sqm or less gross area used for sales

    purposes on the street floor only.

    -Gross area shall be the total of all floors used for mercantile purposeonly. Storage areas are not counted.

    DIVISION 13. MERCANTILE OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    39/54

    SECTION 10.2.13.2 EXIT DETAILS

    Arrangement of Exits

    In no case shall aisle be less than 80 cm in clear width.

    In Class A stores, in an open mall , at least 1 aisle of one and 1.5 m

    minimum width shall lead directly to an exit.

    Discharge from Exits

    The distance of travel from the termination of the enclosure to an

    outside street door is-not more than 15.5 m.

  • 8/13/2019 Fire Code and Plumbing Code

    40/54

  • 8/13/2019 Fire Code and Plumbing Code

    41/54

    DIVISION 13. MERCANTILE OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    42/54

    SECTION 10.2.13.5 SPECIAL PROVISIONS

    Covered Malls and Walkway

    Every covered mall shall have no less than 2 exits located remote

    from each other.

    Every mall shall be provided with unobstructed exit access. In no case shall an exit access through a covered mall be less than

    3 meters and 66 cm in clear width.

  • 8/13/2019 Fire Code and Plumbing Code

    43/54

  • 8/13/2019 Fire Code and Plumbing Code

    44/54

    DIVISION 14

    Business Occupancies

    DIVISION 14. BUSINESS OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    45/54

    SECTION 10.2.14.2 EXIT DETAILSTypes of Exits

    Doors

    Stairs and smoke proof

    enclosures

    Horizontal exits

    Ramps

    Exit Passageways

    Fire escape ladders

    Minimum Corridor Width

    The clear width of anycorridor or passageway

    serving an occupant load of

    50 or more shall be not less

    than 1.12 m.

  • 8/13/2019 Fire Code and Plumbing Code

    46/54

    DIVISION 14. BUSINESS OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    47/54

    SECTION 10.2.14.2 EXIT DETAILS

    Number of Exits

    A single exit shall be permitted for

    a room or area with a total

    occupant load of fewer than 100

    persons, provided that thefollowing criteria are met:

    The exit shall discharge

    directly to the outside at the

    level of exit discharge for the

    building.

    The total distance of travel from

    any point, including travel

    within the exit, shall not exceed

    30 m.

    DIVISION 14. BUSINESS OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    48/54

    SECTION 10.2.14.2 EXIT DETAILS

    Number of Exits

    Any business occupancy not exceeding 3 storeys, and not exceeding

    an occupant load of 30 people per floor, shall be permitted a single

    separate exit to each floor, provided that the following criteria are

    met:

    This arrangement shall be permitted only where the total travel

    distance to the outside of the building does not exceed 30 m and

    where the exit is enclosed.

  • 8/13/2019 Fire Code and Plumbing Code

    49/54

    DIVISION 14. BUSINESS OCCUPANCIES

  • 8/13/2019 Fire Code and Plumbing Code

    50/54

    SECTION 10.2.14.2 EXIT DETAILS

    Arrangement of Means of Egress

    Limitations on common path of travel shall be in accordance with the following:

    Common path of travel shall not exceed 30 m in a building protected

    throughout by an approved, supervised automatic sprinkler system

    Common path of travel shall not exceed 30 m within a single tenant space

    having an occupant load not exceeding 30 persons.

    In buildings other than those complying above, the common path of travel

    shall not exceed 23 m.