10
(217) 352-9330 | [email protected] | artisantg.com -~ ARTISAN ® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment. Artisan Technology Group Full-service, independent repair center with experienced engineers and technicians on staff. We buy your excess, underutilized, and idle equipment along with credit for buybacks and trade-ins . Custom engineering so your equipment works exactly as you specify. Critical and expedited services Leasing / Rentals/ Demos • In stock/ Ready-to-ship !TAR-certified secure asset solutions Expert team I Trust guarantee I 100% satisfaction A ll trademarks, brand names, and br ands appearing herein are the property of their respecti ve owners. Find the Vicor FlatPAC VI-MUL-CQ at our website: Click HERE

Find the Click HERE · 2020. 10. 6. · R1(k1 ) .953 15.8 22.1 41.2 48.7 90.9 R2(k1 )909090 909090 +10%, -10% VLINE > 90 (180) Vac AC Line Interrupted AC Line AC OK DC OK T0 T1 T2

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • (217) 352-9330 | [email protected] | artisantg.com

    -~ ARTISAN® ~I TECHNOLOGY GROUP Your definitive source for quality pre-owned equipment.

    Artisan Technology Group

    Full-service, independent repair center with experienced engineers and technicians on staff.

    We buy your excess, underutilized, and idle equipment along with credit for buybacks and trade-ins.

    Custom engineering so your equipment works exactly as you specify.

    • Critical and expedited services • Leasing / Rentals/ Demos

    • In stock/ Ready-to-ship • !TAR-certified secure asset solutions

    Expert team I Trust guarantee I 100% satisfaction All trademarks, brand names, and brands appearing herein are the property of their respective owners.

    Find the Vicor FlatPAC VI-MUL-CQ at our website: Click HERE

    tel:2173529330mailto:[email protected]://artisantg.comhttps://www.artisantg.com/TestMeasurement/70730-1/Vicor-FlatPAC-VI-MUL-CQ-Single-Output-Autoranging-AC-DC-Switcherhttps://www.artisantg.com/TestMeasurement/70730-1/Vicor-FlatPAC-VI-MUL-CQ-Single-Output-Autoranging-AC-DC-Switcher

  • FlatPAC Family50 to 600 WattAC-DC Switchers

    Application NotesFunctional and Mechanical Layout

    Installation and Operation Guidelines

    Product Description

    The FlatPAC family of user-definable offline power supplies provides a complete

    power solution that incorporates one, two, or three standard Vicor DC-DC converters

    and a front-end subassembly in a modular package. FlatPAC is available with one,

    two, or three outputs and total output ratings of up to 600 W. The two-up and

    three-up models (maximum output 400 W and 600 W) feature an autoranging input,

    which automatically senses the input line voltage and sets the power supply’s input

    range accordingly. FlatPAC’s unique modular design accommodates over 10,000

    different configurations.

    FlatPAC switchers that contain BatMod current source modules instead of VI-200

    converters are indicated by the suffix -BM following the FlatPAC part number.

    BatMod converters provide a programmable output current, rather than a controlled

    output voltage. Consequently, the output supervisory terminal functions differ on

    FlatPACs with BatMod modules.

    F-Series(Strappable Input)

    A-Series(Autoranging Input)

    12Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • Application Notes2

    MOD-DIS Input. Apply a current of 1–30 mA to disable output.

    Forward voltage drop of internal opto diode is 1.65 V max. @

    30 mA max.

    AC-OK and BUS-OK Status Outputs. Output transistors saturated

    if OK. Vce sat. = < 0.4 V @ 1.5 mA. Maximum voltage is 70 Vdc.

    30 mA max.

    Disable

    MOD DIS +

    MOD DIS –

    V

    +

    AC OK –

    AC OK +

    BUS OK –

    BUS OK +

    Status

    1.5mA max.

    V

    +r r

    AC Mains Connections

    Supervisory Connections (2-up and 3-up models)

    AC Mains

    Earth Ground

    MOD DIS –MOD DIS +AC OK –AC OK +BUS OK –BUS OK +

    InternalSupervisoryCircuits(Optocouplers)Autoranging models:

    Do not connectManual strap models: Connect for 115 Vac Open for 230 Vac

    ST2

    ST1

    L2/N

    L1

    GND

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • 3

    +Sense and –Sense must be connected locally or remotely (shown).

    + VOUT

    To Load

    – VOUT

    R110K

    R2

    + OUT

    + SENSE

    TRIM

    – SENSE

    – OUT

    RESISTOR VALUES FOR TRIMMING STANDARD OUTPUT VOLTAGESNominal Output Voltage 5 V 12 V 15 V 24 V 28 V 48 V Trim Range

    R1(kΩ) .953 15.8 22.1 41.2 48.7 90.9

    R2(kΩ) 90 90 90 90 90 90+10%, -10%

    VLINE > 90 (180) Vac

    AC LineInterrupted

    ACLine

    AC OK

    DC OK

    T0 T1 T2 T3 T4

    Conditions: Full Load 90 (180) Vac, AC Line

    Timing Diagram—Status Signals (2-up and 3-up models)

    Output Trimming (All models with VI-200s)

    BatteryCharger

    ExternalControlFunctions

    + OUT

    VTRIMITRIMIMON

    – OUT

    ProgrammableCurrent Source

    12–48VBattery

    +

    ➧ ➧

    Load

    +

    OR

    Typical Applications (FlatPACs with BatMods only)

    Time Interval Min Typ Max Units Notes

    T1-T0 0 0.1 1.0 ms

    T3-T2 0 – – ms

    T4-T2 5 – – ms Ride-through time

    T4-T3 5 – – ms AC fail warning time

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • Functional and Mechanical Layout4

    LF-SeriesSingle output50-200 W

    MA/MF-SeriesSingle output200-400 W

    NA/NF-SeriesSingle output450-600 W

    PA/PF-SeriesDual output100-400 W

    QA/QF-SeriesDual output250-600 W

    RA/RF-SeriesTriple output150-600 W

    NA-, QA-, and RA-Series

    MA-, PA-Series

    LF-Series

    Inputs

    All Models

    1011

    8

    9

    76

    1

    2

    54

    3

    7.38(187,5)

    1.99(50,6)

    4.42(106,7)

    .20(5,1) .18

    (4,6)6.00

    (152,4

    2.288(58,12)

    2.420(61,47)

    7.00(177,8).20

    (5,1) 5 PLACES

    .25(6,4)

    5 PLACES

    .19(4,8)

    12

    ø.150 ± .005(ø3,81 ± 0,13)THRU 6 PLACES

    .18(4,6)

    6.00(152,4)

    .192(4,88)

    2.156(54,77)

    2.54(64,5) .20

    (5,1)

    .87(22,1)

    .20(5,1)

    TYP

    1

    3

    54

    2

    12

    ø.150 ± .005(ø3,81 ± 0,13)THRU 4 PLACES

    .199(5,06)

    .90(22,9)

    3.05(77,5)

    4.96(126,0)

    .25(6,4)

    .20(5,1)

    .20(5,1) .18

    (4,6)

    2.281(57,94)

    9

    7

    11

    8

    6

    1

    2

    54

    3

    10

    5 PLACES

    5 PLACES 4.562(115,87)

    6.0(152

    ø.150 ± .005(ø3,81 ± 0,13)THRU 5 PLAC

    1.37(34,8)

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • 5

    Drawing: P.N. 10873

    NA-Series QA-Series RA-Series

    MA-Series PA-Series

    LF-Series

    Outputs Inputs1 Earthground2 L13 L2/N4 1 ST15 1 ST26 BUS OK+7 BUS OK–8 AC OK+9 AC OK–

    10 MOD DIS+11 MOD DIS–1 Not used on

    autoranging models

    Outputs

    A +OutB +Sense*C Trim*D –Sense*E –Out*On FlatPACs with BatMods:B VTRIMC ITRIMD IMON

    #8-32 STUD

    #10-32 STUD #10-32 STUD

    #8-32 STUD6 PLACES

    04)

    2.76(70,1)

    3.07(78,0)

    E

    DCB

    A

    E

    DCB

    A

    E

    DCB

    A

    E

    DCB

    A

    EDCB

    A

    EDCB

    A .41 (10,41)

    6.95 (176,53)

    6.37 (161,80)5.98 (151,89)5.59 (141,99)5.25 (133,35)

    4.53 (115,06)

    3.95 (100,33)3.56 (90,42)3.17 (80,52)2.83 (71,88)

    2.11 (53,59)

    1.53 (38,86)1.14 (28,96).75 (19,05)

    0

    .25 TYP

    OU

    TP

    UT

    1O

    UT

    PU

    T 2

    OU

    TP

    UT

    3

    OU

    TP

    UT

    1O

    UT

    PU

    T 2

    OU

    TP

    UT

    1

    S

    2.76(70,1)

    #8-32 STUD2 PLACES

    EDCB

    A .41 (10,41)

    2.11 (53,59)

    1.53 (38,86)1.14 (28,96).75 (19,05)

    0

    .25 TYP

    OU

    TP

    UT

    1

    2.76(70,1)

    3.07(78,0)

    002,4)

    12

    #10-32 STUD2 PLACES

    E

    DCB

    A

    #8-32 STUD4 PLACES

    E

    DCB

    A

    EDCB

    A .41 (10,41)

    4.53 (115,06)

    3.95 (100,33)3.56 (90,42)3.17 (80,52)2.83 (71,88)

    2.11 (53,59)

    1.53 (38,86)1.14 (28,96).75 (19,05)

    0

    .25 TYP

    OU

    TP

    UT

    1O

    UT

    PU

    T 2

    OU

    TP

    UT

    1

    ES

    0.41(10,4)

    1.12(28,5)

    9.25(235,0)

    8.61(218,7)

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • Fusing. The FlatPAC’s internal fuses are not user-replaceable. Please return the

    unit to vendor if servicing is necessary.

    Grounding. For safe operation, the FlatPAC unit must be grounded. Connect a

    ground lead to the terminal marked (GND). Use the same wire gauge as that

    specified for your FlatPAC unit’s input voltage connections, below.

    Input Voltage Connections. Connect the line voltage to L1 (hot) and L2N

    (neutral). For one-up FlatPAC models (max. output 200 W), use #16 input wire; for

    two-up and three-up models (max. output 400 W and 600 W), use #14 input wire.

    Recommended connector screw torque is 5 to 7 in-lbs (0.5 to 0.8 N-m). Use your

    FlatPAC model only with the corresponding input voltages and frequencies shown

    in the table below. Either connect or do not connect ST1 to ST2 as indicated.

    Output Wire Gauge. Use the output wire gauge that corresponds to the output

    current of your FlatPAC unit, below:

    105 A–160 A : #4 26 A–40 A : #10 7 A–10 A : #16

    66 A–104 A : #6 16 A–25 A : #12 4 A–6 A : #18

    41 A–65 A : #8 11 A–15 A : #14 0 A–3 A : #20

    Output Voltage Trimming. Do not trim the outputs higher than 110% of their

    nominal output voltage. When an output is trimmed up, do not exceed its

    maximum rated output power.

    Operating Temperature. Do not allow the FlatPAC to exceed its maximum

    operating temperature, which is reached when the heat sink is 85°C. (Full power

    can be delivered up to this temperature.) Heat sink temperature is a function of the

    output power and voltage of the supply, ambient temperature, and airflow across

    the heat sink. Refer to the Vicor Applications Manual to determine the maximum

    ambient temperature for your application. Always use worst-case conditions when

    calculating operating temperature. Note: To ensure proper heat transfer from the

    internal module(s) to the heat sink, the mounting holes through the heat sink (2, 3,

    and 4 holes on one-, two-, and three-up models, respectively) must contain

    torqued screws at all times during operation, whether or not the unit is mounted.

    Installation and Operation Guidelines6

    90–132 Vac 180–264 VacC-Grade Model 47–63 HzStrappable VI–■■F–C ■■ Connect OpenAutoranging VI–■■A–C ■■ Open Open

    90–132 Vac 180–264 VacI-Grade Model 47–440 HzStrappable VI–■■F–I ■■ Connect OpenAutoranging VI–■■A–I ■■ Open Open

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • If the unit is operated unmounted, insert a #6 or metric screw through each hole

    from below and secure with a nut on top, torqued to 6 in-lbs (0.7 N-m).

    Output Terminal Connections. A hardware kit with parts for output terminal

    connections is provided with each FlatPAC unit. The following drawing shows the

    assembly of those parts for the proper connection of metal power terminals.

    Assembly for PCB power terminals is the same except that they do not require an

    external tooth lockwasher. Consult the table below for the recommended torque

    level for each stud size.

    For More InformationThe Vicor Applications Manual and product data sheet contain complete

    information about FlatPAC AC-DC Switchers. To receive literature or to consult

    an applications engineer about installation or operation of this product, contact

    your nearest Vicor office. (See page 8.)

    (Bitte lesen Sie die Sicherheits-Vorschriften auf Seite 8.)

    “AMP” and “Faston” are registered trademarks of AMP, Incorporated, Harrisburg, PA.

    7

    Metal Terminal

    Drawing: P.N. 10894 #1

    Terminal and Terminal RecommendedProduct Model Style Stud Size Torque

    –Output, +OutputLF-, PA/PF-, & PCB 8-32 UNC 10 in-lbs (1.1 N-m)

    RA/RF-SeriesMA/MF- & Metal 10-32 UNC 15 in-lbs (1.7 N-m)

    NA/NF-SeriesQA/QF-Series PCB 8-32 UNC 10 in-lbs (1.1 N-m)

    Metal 10-32 UNC 15 in-lbs (1.7 N-m)Supervisory Sized to accept AMP Faston® insulated All models receptacle #2-520184-2

    EXTERNAL TOOTHLOCKWASHER

    #10 TERMINALRETAINING NUT

    #10 NUT PLATE

    USER OUTPUTTERMINALS

    #10 BRASS STUD

    HELICALLOCKWASHER(FITS WITHIN

    OPENING PROVIDED)

    TERMINAL COVERNEGATIVE

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • Sicherheits-Vorschriften8

    Sicherungen. Die internen Sicherungen im FlatPAC können nicht vom Anwender

    ausgetauscht werden. Für Servicearbeiten schicken Sie das Teil bitte an den

    Händler zurück.

    Erdung. Um den IEC 950 Klasse I Erdungsforderungen zu entsprechen, muß ein

    Erdungskabel an den Anschluß (GND) angeschlossen werden. Für FlatPAC

    Modelle mit einem Modul (max. Leistung 200W) benutzen Sie bitte AWG 16- und

    für Modelle mit 2 und 3 Modulen (max. Leistung 400 W und 600 W) AWG 14-Kabel.

    Eingangsverbindungen. Abhängig von Ihrem FlatPAC Modell und der

    Eingangsspannung müssen ST1 und ST2 offen sein oder miteinander verbunden

    werden—wie nachstehend aufgeführt.

    Modell 90-132 Vac 180-264 Vac

    Strappable (VI–■■F–■■■■ ) Verbinden Offen

    Autoranging (VI–■■A–■■■■ ) Offen Offen

    Betriebstemperatur. Die maximale Betriebstemperatur des FlatPAC-Gerätes darf

    nicht überschritten werden. Dies ist gegeben, wenn der Kühlkörper eine

    Temperatur von 85 Grad Celsius erreicht hat.

    Weitere Informationen. Das Vicor Applications Manual und Produkt-Datenblätter

    enthalten ausführliche Informationen über FlatPAC AC-DC Wandler. Fordern Sie

    bitte Unterlagen bei Vicor oder Ihrer nächsten Vicor Vertretung an.

    Vicor CorporationAndover, MA, U.S.ATel: 978-470-2900Fax: 978-475-6715

    Vicor FranceTel: +33 1 34 52 18 30Fax: +33 1 34 52 28 30

    Vicor GermanyTel: +49 89 962 439 0Fax: +49 89 962 439 39

    Chicago, ILTel: 630-769-8780Fax: 630-769-8782

    Vicor ItalyTel: +39 02 22 47 23 26Fax: +39 02 22 47 31 66

    Vicor U.K.Tel: +44 1276 678222Fax: +44 1276 681269

    Sunnyvale, CATel: 408-522-5280Fax: 408-774-5555

    Vicor Hong KongTel: +852-2956-1782Fax: +852-2956-0782

    Vicor JapanTel: +81-3-5487-3880Fax: +81-3-5487-3885

    Printed in U.S.A. Pt. No. 23786 Rev 4.0 2/04/100M

    Visit Vicor’s Website at:

    vicorpower.com

    Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

  • Artisan Technology Group is an independent supplier of quality pre-owned equipment

    Gold-standard solutions Extend the life of your critical industrial,

    commercial, and military systems with our

    superior service and support.

    We buy equipment Planning to upgrade your current

    equipment? Have surplus equipment taking

    up shelf space? We'll give it a new home.

    Learn more! Visit us at artisantg.com for more info

    on price quotes, drivers, technical

    specifications, manuals, and documentation.

    Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.

    We're here to make your life easier. How can we help you today? (217) 352-9330 I [email protected] I artisantg.com