2
Technical Specification A product of Erba Europe New Generation High Performance Mode Type Whole Blood, Predilute, Capillary Total Parameters: 22 CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-CV, PDW-SD, P-LCR, P-LCC. 3 Part Diff: Lymph % & #, Mid % & #, Gran% & # Principle of measurement RBC/PLT/WBC/ DIFF: Electrical Impedance Hb: Cyanide Free Colorimetry MCV: Measured HCT: Calculated Histograms 3 (WBC/RBC/PLT) Sample Volume Whole Blood : 9 µL Pre-diluted : 20 µl Capillary : 20 µl Linearity Range WBC : 0 - 300 (x 10 3 /µL) RBC : 0.00 - 8.50 (x 10 6 /µL) Hb : 0 - 25.0 (g/dL) HCT : 0 - 67 (%) PLT : 0 - 3000 (x 10 3 /µL) Calibrator ELite H Cal (3mL) Open Vial Stability at 2-8˚C: 7 Days Tri-level Controls Elite H3 CON L, N, H (3mL) Open Vial Stability at 2-8˚C: 16 Days Throughput 60 Tests/Hr Quality Control 500 files with L-J graph X-Bar Analysis Data Storage 50,000 Results with Graphs Dimension (mm) 364x477x417 Weight (Kg) 25 Reagents Erba H360 Dil Erba H360Lyse Elite H Clean Interfaces 4 USB + 1 LAN Port Operating Environment Temperature : 15-35˚C Humidity : 30-85% Power Requirement A.C.100-240V 50/60Hz 200VA ERBA IRELAND ERBA RUSSIA TRANSASIA INDIA ERBA POLAND ERBA GERMANY ERBA UK ERBA USA ERBA CZECH REPUBLIC ERBA TURKEY ERBA FRANCE DELTA BIOLOGICALS Sales & Marketing Largest in the IVD Industry Supply Chain Widest Network in the Industry Customer Support Least downtime 65000+ Installations Transasia - Erba Group Global footprint India Advantage Transasia House, 8 Chandivali Studio Road, Andheri (E), Mumbai - 400 072. T: (022) 4030 9000, F: (022) 2857 3030 E: [email protected] W: www.erbamannheim.com Toll Free Number 1800 130 8226 Karásek 2219/1d, 621 00 Brno, Czech Republic Tel.: +420 517 077 111 E-mail: [email protected] Erba Lachema s.r.o. Manufactured by:

Final H 360 - Erba Mannheim 360 … · Technical Specification A product of Erba Europe New Generation High Performance Mode Type Whole Blood, Predilute, Capillary Total Parameters:

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Technical Specification

A product of Erba Europe

New Generation High Performance

Mode TypeWhole Blood, Predilute, Capillary

Total Parameters: 22CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-CV, PDW-SD, P-LCR, P-LCC. 3 Part Di�: Lymph % & #, Mid % & #, Gran% & #

Principle of measurementRBC/PLT/WBC/ DIFF: Electrical ImpedanceHb: Cyanide Free ColorimetryMCV: MeasuredHCT: Calculated

Histograms 3 (WBC/RBC/PLT)

Sample Volume Whole Blood : 9 µLPre-diluted : 20 µlCapillary : 20 µl

Linearity RangeWBC : 0 - 300 (x 103/µL)RBC : 0.00 - 8.50 (x 106/µL)Hb : 0 - 25.0 (g/dL)HCT : 0 - 67 (%)PLT : 0 - 3000 (x 103/µL)

Calibrator ELite H Cal (3mL)Open Vial Stability at 2-8˚C: 7 Days

Tri-level ControlsElite H3 CON L, N, H (3mL)Open Vial Stability at 2-8˚C: 16 Days

Throughput 60 Tests/Hr

Quality Control 500 files with L-J graphX-Bar Analysis

Data Storage 50,000 Results with Graphs

Dimension (mm)364x477x417

Weight (Kg) 25

Reagents Erba H360 DilErba H360Lyse Elite H Clean

Interfaces 4 USB + 1 LAN Port

Operating Environment Temperature : 15-35˚CHumidity : 30-85%

Power RequirementA.C.100-240V50/60Hz200VA

ERBA IRELANDERBA RUSSIA

TRANSASIAINDIA

ERBA POLAND

ERBA GERMANY

ERBA UK

ERBA USA

ERBA CZECH REPUBLIC

ERBA TURKEY ERBA

FRANCE

DELTA BIOLOGICALS

Sales & MarketingLargest in the IVD Industry

Supply ChainWidest Networkin the Industry

Customer SupportLeast downtime

65000+Installations

Transasia - Erba Group

Global footprint India Advantage

Transasia House, 8 Chandivali Studio Road, Andheri (E), Mumbai - 400 072. T: (022) 4030 9000, F: (022) 2857 3030 E: [email protected]: www.erbamannheim.com

Toll Free Number

1800 130 8226Karásek 2219/1d, 621 00 Brno, Czech RepublicTel.: +420 517 077 111

E-mail: [email protected]

Erba Lachema s.r.o.Manufactured by:

Sample Analysis Review

QC Reagent

Add Diluent Cal

+

Setup Service

SampleAnalysis Review QC Reagent

ManagementLIS

QC Type L-J Print Delete Outliers

QC Settings QC Analysis QC Table

File No.:

Existing /

Editor: ad

QC Mode: Whole Blood

Exp. Date: 05-05-2019

Lot No.: B0219

Level: Low

QC Sample ID:

1

1

2

3Para.

Lower Limit

01-01-1970 08:20:42

Operator admin

MeanSDCV%

Next Sample: 1Sampel Count

Mode: VWBUser.admin

Erba H360 DH running out.06-03-2019 16:59:08

WBC2.13

2.502.001.50

Lym%58.2

66.557.548.5

Gran%33.4

41.832.523.8

Mid%8.4

18.89.80.8

2.0630.1095.3

59.021.422.4

32.311.253.9

8.671.0111.6

1919

QC Graph

10.4” large coloured LCD touch screen with graphic icons Single page view of full report Convenient daily maintenance with single shut down procedure

CONVENIENT

Excellent short & long term precision Highly accurate with results correlating with microscopic examination & clinical findings Specific flagging messages to alarm for microscopic slide review

PRECISE & ACCURATE

Just 9 µL sample volume: all age groups

P-LCR, P-LCC, PDW-SD, PDW–CV aids di�erential diagnosis of cases with abnormal platelet counts

RDW-SD, RDW-CV & MCV aids in screening for causes of anaemia

MORE WITH LESS

ADVANCED SOFTWARE Large storage capacity: 50,000 reports with graphs

4 USB ports Bar code scanner, external printer, key board, pen drive

1 LAN port for bi-directional interfacing (Optional LIS solution)RIMS

Real time Inventory Management System with RFID

RIMS

ADDMUnique Auto Diluent

Dispensing Mechanism

CUSTOMIZABLE Transcribe other test results -

consolidate reports

COMPACT AUTOMATED HEMATOLOGY ANALYSER WITH 22 REPORTABLE PARAMETERS

0 100 200 fL

0 10 20 30 fL

Para. Arrow Result Unit WBC 5.19 103/ul Lym% 37.3 % Gran% 53.8 % Mid% 8.9 % Lym# 1.94 103/ul Gran# 2.79 103/ul Mid# 0.46 103/ul RBC 5.48 106/ul HGB 15.6 g/dL HCT 46.3 % MCV 84.4 fL MCH 28.5 pg MCHC 33.8 g/dL RDW-CV 13.9 % RDW-SD 47.2 fL PLT 243 103/ul MPV 9.3 fL PDW-SD 11.0 fL PDW-CV 15.0 % PCT 0.227 % P-LCR 22.5 % P-LCC 55 103/ul

Sample ID 6304 VWB

27-02-2019 19:41:21Name

Age

Mode

Run Time

Gender

WBC MessageWBC

RBC MessageRBC

PLT MessagePLT

Previous Next Pre-entry PrintMode &ID

PatientInfo.

CancelValidation

Sample Review QCAnalysisLIS

0 100 200 300 fL

Mode: VWBNext Sample: 1

Sample Count User:admin

Startup initializetion notexecuted.

06-03-2019 15:55:21

ReagentManagement