    EQUS Vacuum Autoclave Saturn TAT-202 B

    Great Flexibility

    1. Comply with Hollow load A instrument test,specialized in sterilizing dental hand pieces and hollow instruments.

    2. Digital adjustable timer with 16 memory programmable cycles

    3. Independent drying system is easy for the operator to set the time

    from o min. ~ 99 min.

    3

  • 8/13/2019 Final Catalogue Equamaster - Compile

    5/16

  • 8/13/2019 Final Catalogue Equamaster - Compile

    6/16

    Swing-hinged SR-Series

    EZ-SV/SR series Sterilizers are designed to focus on research center,

    animal laboratory and medical center for their large volume &

    easy operating.

    1. Preset with 5 programs for wrapped item, unwrapped instrument, liquid, B&D test and free setting.

    2. Electric swing clutch door is used for easy operation. Manual operation is available in case of electric failure.

    3. Silicone rubber gasket is used for airtight sealing.

    4. Open instrument can be flash sterilized in 3 minutes while wrapped items can be

    sterilized in 10 minutes at 134.

    5. LCD touch control screen: 5-1/2 to display date, temperature, pressure, cycle stages and course of time

    against pressure and temperature.

    6. Automatic pressure control system for pressure and vacuum setting which accuracy is between 0.1psi.

    7. Printer system is used for the record of sterilizing time, sterilizing No., cycle No., operator No., temperature set,

    time set, pressure/vacuum set, maximum & lowest temperature, actual heating, sterilizing and drying time,

    total time used and time of open door etc....In case of out of printing paper, the cycle proceeding will keep on

    heat-sensitive printing paper is used to print out 19bps and there is no ink need.

    8. HEPA air filter cartridge is used for 0.2m air purge, flowage more than 95LPM.

    Feature

    5

    Swing-hinged SR-Series

  • 8/13/2019 Final Catalogue Equamaster - Compile

    7/16

    Desk-top ST-Series

    EZ-ST series Autoclave is designed for flash sterilization of

    medical instruments in operation room, plastic surgery.

    1. Double shell designed for the excellent sterilizing and drying function.

    2. Patented locking device used for easy door operation,

    no rotation needed to lock chamber door inposition.

    3. the preset program and press "start" button, the full cycle runs and is traced by

    illuminated indicators automatically.

    4. Flash cycle takes few minute for sterilization.

    5. Maximum allowable working pressure: 2.8kg/cm.

    Maximum working temperature: 137.

    6. Built-in steam generator with water feeding system for high performance.

    7. Steam trap expels the unsaturated steam and timer acts only when temperature is built up to

    ensure effectual sterilizations.

    8. Stainless steel solenoid valve used for long life service.

    9. Two tanks used for clean water and used water separately to avoid piping blocked up.

    10. Set value and actual value display at the same time for easy read.

    11. IC-board control system with digital timer count-down for easy operation.

    12. Maximum range of dial pressure gauge: 6 kgf/cm2, range of digital thermal indicator:

    room temperature 199.

    Feature

    Autoclave

    6

  • 8/13/2019 Final Catalogue Equamaster - Compile

    8/16

    Autoclave

    Vertical-sliding SV-Series

    EZmed SV/SR series Sterilizers are designed tofocus on research center,

    animal laboratory and medical center for their

    large volume & easy operating.

    1. Preset with 5 programs for wrapped item, unwrapped instrument, liquid, B&D test and free setting.

    2. Electric vertical sliding door is used for easy operation. Manual operation is available in case of electric

    failure.

    3. Silicone rubber gasket is used for airtight sealing.

    4. Open instrument can be flash sterilized in 3 minutes while wrapped items can be sterilized in 10 minutes.

    5. LCD touch control screen: 5-1/2 to display date, temperature, pressure, cycle stages and course of timeagainst pressure and temperature.

    6. Automatic pressure control system for pressure and vacuum setting which accuracy is between 0.1psi.

    7. Printer system is used for the record of sterilizing time, sterilizing No., cycle No., operator No., temperature

    set,time set, pressure/vacuum set,maximum & lowest temperature, actual heating, sterilizing and drying time,

    total time used and time of open door etc... In case of out of printing paper,the cycle proceeding will keep

    on heat-sensitive printing paper is used to print out 19bps and there is no ink need.

    8. HEPA air filter cartridge is used for 0.2m air purge, flowage more than 95LPM

    7

  • 8/13/2019 Final Catalogue Equamaster - Compile

    9/16

    Vertical-loading SS-Series

    EZ SS-series Autoclave is designed to dissolve or sterilize cultures and laboratory utensils in

    medical center, R&D center, examine center and biochemical technology fields

    Feature

    1. Patented locking device used for easy door operation, no rotation needed to lock chamber door in position.

    2. Chamber shell is made of stainless steel with inside surface polished.

    3. Cabinet is made of steel with electro-powder painting.

    4. Attached with 5-liter collection bottle kits for used steam and condensations.

    5. Fill water to chamber, switch on power, the preset program and press "start" button,

    the full cycle of heatingsterilizingexhaustingdryingcompletion will run and trace

    by illuminated indicators automatically.

    Vertical-loading SS-Series

    8

  • 8/13/2019 Final Catalogue Equamaster - Compile

    10/169

  • 8/13/2019 Final Catalogue Equamaster - Compile

    11/16

    10

  • 8/13/2019 Final Catalogue Equamaster - Compile

    12/1611

  • 8/13/2019 Final Catalogue Equamaster - Compile

    13/1612

  • 8/13/2019 Final Catalogue Equamaster - Compile

    14/1613

  • 8/13/2019 Final Catalogue Equamaster - Compile

    15/1614

  • 8/13/2019 Final Catalogue Equamaster - Compile

    16/16

    WH-Series

    EZ WH-30 Washer is used for washing or

    washing with pasteurizing of medical

    respiration hoses and parts to get the best effects

    Description

    1. A full cycle from water feeding, detergent adding, washing, rinsing, dehydration,

    Pasteurizing and draining will be automatic operated by PLC control system.

    2. Touch control/display system with programs preset for easy ion.

    3. Heater system included for where hot water can not reach to 70.

    4. Mounted with stainless steel water pump for long life service.

    5. Printer with rewind system attached for the record of the data such as date,temperature, time and progressing of the full cycle.

    6. The temperature can be set from room temperature to 95. In case of overheating, a

    buzzer alarms and the power turns off automatically.

    7. Time for washing and Pasteurizing can be set from 0 to 99 minute and displayed in the touch screen.

    8. The construction of washer is thoroughly made of stainless steel type 304.

    9. Automatic door operation and loads elevation mechanism for heavy carrying capacity

    10. Rotary washing system supplied, air and bubble inside the tube can be removed completely.