Distributed PID Control and I/O
2500 - What is it?2500 - What is it?
file/ 2
2500 - Eurotherm Distributed Control & I/O2500 - Eurotherm Distributed Control & I/O
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
vePres
ure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Aux
Air
Aux
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Aux
Gas
Aux
Lam
p
SCADA PLC2700
(in future)2900
Distributed I/O and EUROTHERM PID
PC300 LCM
file/ 3
Hot swap I/O module Expandable Three Year Warranty
Hot swap I/O module Expandable Three Year Warranty
4, 8, 16 way bases 2, 4 or 8 loops per base AI2, AI3, AI4, AO2, RLY4, LGC4,
DI4, DI8 modules iTools Windows Configurator
4, 8, 16 way bases 2, 4 or 8 loops per base AI2, AI3, AI4, AO2, RLY4, LGC4,
DI4, DI8 modules iTools Windows Configurator
2500 Features2500 Features
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
ve
Pres
ure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Aux
Air
Aux
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Aux
Gas
Aux
Lam
p
file/ 4
Up to 8 loops per base Each loop can be:
- Single PID loop
- Ratio control
- Cascade pair
- Overide control With standard analogue output
– OR TPO outputs
– OR Raise / Lower output for valve positioning.
Up to 8 loops per base Each loop can be:
- Single PID loop
- Ratio control
- Cascade pair
- Overide control With standard analogue output
– OR TPO outputs
– OR Raise / Lower output for valve positioning.
Control LoopsControl Loops
B_PID L_PID
VP
SPSelector
PVSelector
OP_CON
Cascade
Override
Single
FeedForward
ON_OFF
+
+
Loop Break
v
v
v
To OPDriver
User Variables: 8 real valuesAnalogue functions: 16 e.g. *,/,+,-, sample and hold, and lots more.Digital functions: 16 e.g. OR,AND,XOR,LATCH<,>
User Variables: 8 real valuesAnalogue functions: 16 e.g. *,/,+,-, sample and hold, and lots more.Digital functions: 16 e.g. OR,AND,XOR,LATCH<,>
User Wiring
file/ 5
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
vePres
ure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Aux
Air
Aux
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Aux
Gas
Aux
Lam
p
Plug-in I/O Controller-• H3048 based (32bit) - 2 loop control - cascade control - Soft Wiring - ST, Gain sched. etc - I/O
Plug-in I/O Controller-• H3048 based (32bit) - 2 loop control - cascade control - Soft Wiring - ST, Gain sched. etc - I/O
I/O Bases From 4 up to a maximum of 16 modules
I/O Bases From 4 up to a maximum of 16 modules
I/O NetworkMODBUSProfibus-DP…...
I/O NetworkMODBUSProfibus-DP…...
DIN-rail or wall mount
Terminals One for every wirePlug in terminal UnitsWith or without fuses
Terminals One for every wirePlug in terminal UnitsWith or without fuses
Plug-In I/O Modules circuitry - low cost - optional fuses- SW configured
* dual analogue input * dual analogue output * quad digital input * quad logic out * quad relay output
Plug-In I/O Modules circuitry - low cost - optional fuses- SW configured
* dual analogue input * dual analogue output * quad digital input * quad logic out * quad relay output
2500 DIN Rail Controller2500 DIN Rail Controller
•Executes 2 loops @ 110mSec, 8 loops @ 220mS • Soft User “Wiring”. • Configuration by “iTools” on a PC
•Executes 2 loops @ 110mSec, 8 loops @ 220mS • Soft User “Wiring”. • Configuration by “iTools” on a PC
file/ 6
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
ve
Pres
ure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Aux
Air
Aux
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Aux
Gas
Aux
Lam
p
The unit is supplied as follows: Base, 2500B Controller Module, 2500C I/O Modules, 2500M Terminal Strips, 2500T Power Supply, 2500P
The unit is supplied as follows: Base, 2500B Controller Module, 2500C I/O Modules, 2500M Terminal Strips, 2500T Power Supply, 2500P
2500 DIN Rail Controller
I/O ModulesI/O Modules
file/ 7
Power supply
An external 24 VDC power supply is required. The voltage range 18 VDC to 28 VDC
A system with 4 analog inputs, 4 analog outputs, 4 digital inputs and 4 digital outputs requires 0.5 amps.
Eurotherm offers 3 24VDC supplies
2.5 amp (60 watt
5 amp (120 watt)
10 amp (240 watt) The Eurotherm supply has:
Will hold up power for 20-37 ms. On power fail
Has watchdog relay
file/ 8
Terminal units snap in
Modules changeable “live” (except relay)
DIN rail mount
4, 8, or 16 way units
2500 - Base2500 - Base
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
vePres
sure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Air
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Gas
Aux
Lam
p
file/ 9
Terminal Unit, 2500T
One for each module including IOC Three Analog input terminal units,
– TC
– DC/ RTD
– ma. Fuses available for relay output (July 99)
One terminal for every wire
file/ 10
The Control Module (IOC)
Currently 4 variants
Data acquisition only
Data acquisition with Application Blocks
2, 4 or 8 PID loops
2, 4 or 8 PID loops with Application Blocks
IOC does all calculations;
PID, Application Blocks, communications
Hea
t
Tem
p
Inne
r T
emp
Coo
l
Rai
se
Low
er
Val
vePres
ure
Run
Res
et
Hol
dSe
rvo
Frid
geL
ight
1
Loa
dL
ight
2
Mai
n A
ir
Mai
n Fa
n
Aux
Air
Aux
Fan
Inpu
t Supp
ly
Mai
n G
as
Mai
n L
amp
Aux
Gas
Aux
Lam
p
The IOC goes in the left most slot
file/ 11
IOC Status LED’s
X
C
S*
2500
LED Color ON ALL OFF
*S
C
Green
Yellow
Yellow
Normal operation
Stand-by (future)
Configuration
Self test failed onpower up
LED Colour ON OFF Yellow IO network or
configuration portcommunicating
LED Colour ON OFFX Red IOC reset or
Module missing,faulty or wrong type
Normal operation
FlashingX Red Power on self test
failed
file/ 12
IOC Configuration port
X
CS*
2500RJ11 Socket on the IOC
RS232 port
Max baud rate is 9600
Using this socket outs the IOC in Config. mode
Will appear at both Address 255 & the address set by the address switches
Addresses between 65 and 254 software settable only with all switches set to zero
RJ45 Socket on the Terminal Unit
RS 485
Max baud rate is 32,400
Terminator required in the last socket
file/ 13
Communications- (Control Module)
ON
OFF
12345678
12481632OP
EP
Switch position
Modbus Address
P Parity on
P Parity off
O Odd
E Even
The 2500 system allows communications using either MODBUS or PROFIBUS
The MODBUS addresses are selected by the DIL switch on the termination assembly beneath the IOC
Address 05, Parity off
Terminator
RJ45 CommsLine
Terminator
2900or
Computer
file/ 14
2500M/AI2 2-channel Analogue input Module2500M/AI2 2-channel Analogue input Module
Low level range
High level range
Resolution
Linearity
Calibration accuracy
User calibration
Thermocouple types
Potentiometer input
-100 to +100mV
0-20mA or 0-10Vdc
<2uV for low level inputs
<0.2mV for high level inputs
Better than 0.2OC
+/- 1OC or +/- 0.2% of reading
Low and high offsets can be applied
All common types, RTD, Zirconia probe
330 to 15Kohm
Functional insulation *
Zirconia Probehi Z input
A1 C1
Zi
A2 C2
Zi
A1 C1 A2 C2
I1 B1
H1
B2I2
H2
Dual V ormV
A1 C1 A2 C2
I1 B1
H1
B2I2
H2
A1 C1
A2 C2
V
V
3-wire Pt100
A1 C1 A2 C2
I1 B1
H1
B2I2
H2
PRT
C1I1 A1
PRT
I2 C2A2
Dual mA
A1 C1 A2 C2
I1 B1
H1
B2I2
H2
A1 C1
A2 C2
mA
mA
Dual T/C
1+ 1- 2+ 2-
PRT
C1I1 A1
PRT
I2 C2A2
B1
B2
A1 C1 A2 C2
I1 B1
H1
B2I2
H2
4-wire Pt100
file/ 15
2500M/AI3 3-Channel high level Analogue Input Modules
Input range
Resolution
Linearity
Calibration accuracy
User calibration
Power Supply
-20mA to +20mA< 0.5uA
<0.003% of range
+/- 0.01% of range, 0.05% of reading
Low and high offsets can be applied
nominal 24Vdc @ 25mA for two wire transmitters
Functional insulation *
Three Channel Milli-amps (mA)
Isolated 24v Supply Two wire Tx,
I1 I2 I3
C1 C2
P1 P2
C3
P3
P1 C1
mA
P2 C2
mA
P3 C3
mA
I1 C1
mA
I2 C2
mA
I3 C3
mA
Three Channel Milli-amps (mA) Remote powered
two wire Tx
I1 I2 I3
C1 C2
P1 P2
C3
P3
file/ 16
2500M/AO2 2-channel Analogue output Module2500M/AO2 2-channel Analogue output Module
Range
Resolution
Analogue output functions
Output Load
0-20mA, 0-10VDC (isolated)
1 part in 10,000
Selectable using User Wiring
Up to 600 ohms
1+ 1-
V
2+ 2-
mA
1+ 1-
mA
R
1+ 1- 2+ 2-
1+ 1-
V
R
file/ 17
2500M/DI4 4-channel Digital Input Module2500M/DI4 4-channel Digital Input Module
Contact closure inputs
24Vdc Logic inputs
Digital input functions
Switching voltage: As supply (18 to 30Vdc)Switching current: 10mA(Initial, 1mS 100mA sink for clean switching)(isolated from system, shared common)
Off state: -3 to 5Vdc @ <-0.4mAOn state: 10.8 to 30Vdc @ 2.5mA(isolated from system, shared common)
Selectable using User Wiring
+ -
C1
+ -
C
+ -
C
+ -
C3
2
4
24Vdc Logic Inputs
1 2 3 4
C C
C
CC
V+ V+ C
1 2 3 4
C C
C
CC
V+ V+ C
V+ V+ C C
18-30Vdc
-
+
1 C
3 C
2 C
4 C
Contact Inputs
Link for voltage mode
file/ 18
2500M/DI8 8-channel Digital Input Module
Contact closure inputs
Logic inputs (current sinking)
Digital input functions
Open circuit voltage: 24V dc nominalShort circuit current: 10mAOff state: <100ohm input resistanceOn state: >28Kohm input resistance
Off state: -3 to 5VdcOn state: 10.8 to 30Vdc @ <10mA
Selectable using iTools
Functional isolation
1 3 5 7
C1 C2
8
C4C3
2 4 6
Contact Inputs
1 C1 2 3 C2 4
7 C4 85 C3 6
Logic Inputs
1 3 5 7
C1 C2
8
C4C3
2 4 6
+ -
C11
+
2
+ -
C35
+
6
+ -
C23
+
4
+ -
C47
+
8
file/ 19
2500M/DO4 4-channel Relay output Module2500M/DO4 4-channel Relay output Module
Switching current & volts
Digital output functions
• Max: 2A, 264Vac resistive• Min: 12Vdc/ac, 100mA (Will work with 2500 logic inputs)
• Time Proportioning control, • Motorised valve control• Alarms and events
B4 C4A4A1 B1 A2 B2 A3 B3
B1 B2 B3 B4
A1 A2
C4
A4A3
(3 n/o, 1 c/o relay)
file/ 20
2500M/DO4/LOGIC 4-channel mA logic output2500M/DO4/LOGIC 4-channel mA logic output2500M/DO4/24V 4-channel voltage logic output2500M/DO4/24V 4-channel voltage logic output
Quad 10mA logic output
Quad 24Vdc logic output
Self-powered
Digital output functions
• As supply (12-30Vdc), 10mA current source (isolated from system, shared common)
• Voltage source as supply, 100mA max (isolated from system, shared common)
• In the pipe-line
• PID Time Proportioning, motorised valves.• On/off - for alarms and events.
V+ V+ C C
C C CC 2 3 41
Both types of Outputs
12-30Vdc
4321
-
+
1 2 3 4
C C
C
CC
V+ V+ C