21
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM 8d COMMON NAILS @ 6" O.C. EACH SIDE CONTINUOUS SEALANT AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY MANUFACTURER FOAM CORE DRYWALL OUTSIDE SKIN Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 - SIPA | Structural Insulated Panel Association. 2 wall-to-wall panel connections corner wall connection. 8d common nails @ 6" o.c. both sides concrete or masonry foundation

  • Upload
    lehanh

  • View
    216

  • Download
    1

Embed Size (px)

Citation preview

SIPS SCREWS WITH MINIMUM 1" PENETRATIONIN WOOD MEMBER IN SIP WALL PANELCONNECTED TO @ 24" O.C. MAXIMUM

8d COMMON NAILS@ 6" O.C. EACH SIDE

CONTINUOUS SEALANTAS RECOMMENDED BY MANUFACTURER

CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER

CONTINUOUS SEALANTEACH SIDE OF FRAMING TYP.AS RECOMMENDEDBY MANUFACTURER

FOAMCORE

DRYWALL

OUTSIDESKIN

Fig. 2

WALL-TO-WALL PANEL CONNECTIONS

CORNER WALL CONNECTION

8d COMMONNAILS @ 6" O.C.BOTH SIDES

CONCRETEOR MASONRYFOUNDATIONWALL

BE SURE OUTSIDESKIN IS SUPPORTEDBY SILL PLATE

DRAINED ANDVENTILATEDCLADDING

MINIMUM 1/2" (13MM) DIAMETERANCHOR BOLTS @ 6 FEET O.C.MAXIMUM

CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURER

TREATEDSILL PLATE

SILL SEALER

16d NAILS INTO SILLPLATE @ 16" O.C.

FIELD INSTALLEDPANEL BOTTOMPLATE

FLOOR JOIST

SIP WALL

SUBFLOOR OR COMBINED SUBFLOORAND UNDERLAYMENT

DRYWALL

TERMITE SHIELD

Fig. 3

FOUNDATION CONNECTION DETAIL A

FOUNDATION CONNECTIONS

MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS@ 6 FEET O.C. MAXIMUM

8d COMMONNAILS @ 6"O.C. EACH SIDE

CONCRETE ORMASONRYFOUNDATIONWALL

CAPILLARY BREAK,MIN. 6 MIL POLY ORMIN. 3/4" PRESSURE-TREATED PLYWOODUNDER SILL PLATEAND BOTH FACES

DRAINED ANDVENTILATEDCLADDING

CONTINUOUS SEALANT EACH SIDE OF FRAMINGTYP. AS RECOMMENDED BY MANUFACTURER

FIELD INSTALLEDTREATED BOTTOMPLATE

DRYWALL

SIP WALL

TERMITE SHIELD

Fig. 4

FOUNDATION CONNECTION DETAIL B

FOUNDATION CONNECTIONS

16d NAILS INTO FLOORJOIST PLATE @ 16" O.C.WHEN USED AS BRACING(3) 16d @ 16” O.C.

ANCHOR BOLT ASREQUIRED BY CODE

CONTINUOUS SEALANTAT EACH SIDE OFFRAMING TYP. ASRECOMMENDED BYMANUFACTURER

MANUFACTURERSRECOMMENDATIONS

SPACING

OR MASONRYFOUNDATION WALL

6 MIL POLY OR MIN.3/4" PRESSURE-TREATED PLYWOODUNDER SILL PLATE AND BOTH FACES

TREATEDSILL PLATE

NAILS @ 6"SUBFLOOR OR COMBINED SUBFLOORAND UNDERLAYMENT, TYP.

FLOOR JOIST

TREATED BOTTOM

DRYWALL

DRAINED ANDVENTILATEDCLADDING

SIP WALL

USE NAILS PER

FOR SIZE AND

CONCRETE

CAPILLARY BREAK, MIN.

8d COMMON

O.C. EACH SIDE

FIELD INSTALLED

PLATE

Fig. 5

FOUNDATION CONNECTIONS

FOUNDATION CONNECTION DETAIL C

DRYWALL

STRUCTURAL SUPPORT MEMBER WITHMIN. 1-1/2" BEARING FOR EACH SIDE OFPANELS

SEALANT ASRECOMMENDED BYMANUFACTURER

INSTALLED WOOD

SIPS SCREWS WITH 1"MIN. PENETRATION INTOSTRUCTURAL SUPPORT@ 24" O.C. MINIMUM

SIP TAPE ATRIDGE REQUIRED

8d COMMON

O.C. BOTH SIDES

FINISH ROOFING MATERIAL

EACH SIDE OF FRAMING

AS RECOMMENDEDBY MANUFACTURER

ROOFING FELT

FOAM RIDGE CAP

SIP ROOFPANEL

CONTINUOUS FIELD

RIDGE SUPPORTBEAM SHOWN

NAILS @ 6"

CONTINUOUS SEALANT

AND BOTH FACES

Fig. 6

ROOF-TO-ROOF PANEL CONNECTIONS

FOAM RIDGE CAP DETAIL

SIPS SCREWS W/ MINIMUM 1"PENETRATION INTOSTRUCTURAL SUPPORT@ 24" O.C. MINIMUM

RIDGE SUPPORTBEAM

SIP TAPE ATRIDGE REQUIRED

ROOFINGFELT

FINISHEDROOFINGMATERIAL

MINIMUM 3/8" GAPFOR SEALANT ASRECOMMENDED BYMANUFACTURER

BLOCKING AS REQUIREDBY STRUCTURAL CONDITIONS

Fig. 7

ROOF-TO-ROOF PANEL CONNECTIONS

BEVELED SIP RIDGE DETAIL

DRAINED ANDVENTILATEDCLADDING

SIP WALL PANEL

TOP PLATE

ROOFINGFELT

DRYWALL

SIP ROOFPANEL

PANEL SCREW

FINISHEDROOFINGMATERIAL

8d COMMON NAILS@ 6" O.C. EACH SIDECONTINUOUS

SIDE OF FRAMING

BY MANUFACTURER,AND ROOF PANEL

SEALANT EACH

AS RECOMMENDED

2x JOINT

Fig. 8

ROOF-TO-WALL PANEL CONNECTIONS

BEVELED SIP WALL

CONTINUOUS SEALANT EACH SIDEOF FRAMING AS RECOMMENDED BYMANUFACTURER

DRYWALLCONTINUOUS SEALANT EACH SIDEOF FRAMING AS RECOMMENDED BYMANUFACTURER

8d COMMON NAILS@ 6" O.C. BOTH SIDES

DRAINED ANDVENTILATEDCLADDING

SIP WALL PANEL

TOP PLATE

WEDGE INFILL PIECE

SIP ROOFPANEL

ROOFINGFELT

PANEL SCREW

FINISHEDROOFINGMATERIAL

CONTINUOUSSEALANT EACHSIDE OF FRAMING,AND ROOF PANEL2x JOINT

Fig. 10

ROOF-TO-WALL PANEL CONNECTIONS

WEDGE INFILL PIECE

6" O.C. BOTH SIDESCONTINUOUS SEALANT BOTH SIDESTYP. OF FRAMING AS RECOMMENDEDBY MANUFACTURER

SIP TAPE ATRIDGE REQUIRED

FINISHED ROOFINGMATERIAL

CONTINUOUS SEALANT TYPICALAS RECOMMENDED BYMANUFACTURER

8d COMMON NAILS

ROOFINGFELT

@ 16" O.C.16d COMMON NAILS

Fig. 11

RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG)

ROOF-TO-ROOF PANEL CONNECTIONS

16d COMMON NAILS @ 16" O.C.WHEN USED AS BRACING (3) 16dCOMMON NAILS @ 16" O.C.

CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURER

TOP FLANGE METAL FLOOR JOISTHANGAR (BY OTHERS)

FLOOR JOISTS

3/4" T&G FLOOR SHEATHING(GLUED & NAILED) TO EXTENDOVER TOP OF SIP WALL

STANDARD WIRE CHASE

METAL STRAPAS REQUIREDOR LTP4SIMPSON CLIP

CAP PLATE

CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDED BYMANUFACTURER

DRYWALL

8d COMMONNAILS @ 6"O.C. BOTH SIDES

2x BOTTOMPLATE

DRAINED ANDVENTILATEDCLADDING

SIP WALLPANEL

DRYWALL

FIRST FLOOR

SECOND FLOOR

Fig. 12

2ND FLOOR CONNECTION DETAILS

HANGING FLOOR

FLOOR JOISTS (I-JOIST SHOWN)

3/4" T&G FLOOR SHEATHING(GLUED & NAILED) TO EXTENDOVER TOP OF SIP WALL

16d COMMON NAILS @ 16" O.C.WHEN USED AS BRACING (3) 16dCOMMON NAILS @ 16" O.C.

CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURERBOTH SIDES

8d COMMONNAILS @ 6" O.C.BOTH SIDES

DRAINED ANDVENTILATEDCLADDING

2x BOTTOMPLATE

SIP WALLPANEL

METAL LATERALTIE PLATE NAILEDTO BOTTOM ORSHIM PLATES ANDRIM BOARD

METAL LATERALTIE PLATE NAILEDTO BOTTOM ORSHIM PLATES ANDRIM BOARD

RIM BOARD

FIRST FLOOR

INSULATION

DRYWALL

STANDARD WIRE CHASE

8d COMMONNAILS @ 6" O.C.

CAP PLATE AS REQUIREDBY MANUFACTURER

CONTINUOUS SEALANT EACH SIDEOF FRAMING TYP. AS RECOMMENDEDBY MANUFACTURER

DRYWALL

SECOND FLOOR

Fig. 13

RIM BOARD

2ND FLOOR CONNECTION DETAILS

AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA.

CONTINUOUSSEALANT EACH SIDEOF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER

SOFFIT BOARD

DRIPEDGEFLASHING

FASCIA

CONTINUOUS SEALANT ASRECOMMENDED BYMANUFACTURER

ROOF-TO-WALL PANELCONNECTION DETAILSHOWN ELSEWHERE

ROOFING FELT

FINISHED ROOFING MATERIAL

SIP ROOF PANEL

Fig. 14

EAVES DETAIL A

EAVES DETAILING

SIP SCREW

SOFFIT BOARD

AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA

CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER

2X BLOCKINGTO SUPPORTFASCIA BOARD

FASCIA

DRIP EDGEFLASHING

2x FRAMING MEMBER

CONTINUOUS SEALANT ASRECOMMENDED BYMANUFACTURER

8d COMMON NAILS@ 6" O.C. BOTH SIDES

ROOF-TO-WALL PANEL CONNECTIONDETAIL SHOWN ELSEWHERE

SIP ROOF PANEL

FINISHED ROOFING MATERIAL

ROOFING FELT

Fig. 15

EAVES DETAIL B

EAVES DETAILING

SIP ROOF PANEL

DRIP EDGE

CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP.RECOMMENDED BY

AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA.

FINISHED ROOFING MATERIAL

2x FRAMING MEMBER

2x FRAMING MEMBER

SOFFIT BOARDFASCIA

8d COMMON NAILS@ 6" O.C. BOTH SIDES

CONTINUOUS SEALANTRECOMMENDED BYMANUFACTURER

USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.

ROOFING FELT

SIP SCREW

Fig. 16

EAVES DETAILING

EAVES DETAIL C

BEVELED

TO SUPPORTFASCIA BOARD

CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER

DRIP EDGEFLASHING

AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA

SOFFIT BOARD

FASCIA

SIP ROOF PANEL

ROOFING FELT

FINISHED ROOFING MATERIAL

USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.

8d COMMON NAILS@ 6" O.C. BOTHSIDES

CONTINUOUS SEALANTAS RECOMMENDED BYMANUFACTURER

ROOF-TO-WALL PANELCONNECTION DETAILSHOWN ELSEWHERE

BLOCKING

Fig. 17

EAVES DETAILING

EAVES DETAIL D

USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.

CONTINUOUS SEALANTAS RECOMMENDED BYMANUFACTURER

ROOF-TO-WALL PANEL CONNECTIONDETAIL SHOWN ELSEWHERE

8d COMMON NAILS @6" O.C. BOTH SIDES

AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA

CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BY

DRIP EDGE

FINISHED ROOFING MATERIAL

FASCIA

SOFFIT BOARD

SIP ROOF PANEL

ROOFING FELT

Fig. 18

EAVES DETAIL E

EAVES DETAILING

Spud
Typewritten Text

CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER

EXPANSION GAP 1/8"

CHASE FOR EXPANDEDFOAM SEALANT

8d COMMON NAILS@ 6" O.C. EACH STRIPAND EACH SIDE

SIP PANEL

SEALANT AS RECOMMENDEDBY MANUFACTURER

Fig. 19

WALL-TO-WALL VERTICAL PANEL CONNECTIONS

SURFACE SPLINE FOR VERTICAL SPLICE

2x FRAMING AROUNDWINDOWS AND DOOR OPENINGS

Fig. 21

DOOR AND WINDOW FRAMING

EXPANSION GAP 1/8"

8d COMMON NAILS@ 6" O.C. EACH PANELAND EACH SIDE

(2) ROWS 16d COMMONNAILS@ 16" O.C. MINIMUM

SIP PANEL

CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER

Fig. 20

WALL-TO-WALL VERTICAL PANEL CONNECTIONS

DIMENSIONAL LUMBER SPLINE

VALLEYFLASHING

8d COMMON NAILS @6" O.C. EACH PANELAND EACH SIDE

CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. ASRECOMMENDED BYMANUFACTURER ATSUPPORT MEMBERS

16d COMMONNAILS @ 16"O.C. MINIMUM

SIP ROOF PANEL

DRYWALL

CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER

STRUCTURAL SUPPORT

SIP TAPESIPS SCREWW/ MINIMUM 1"PENETRATIONINTO STRUCTURALSUPPORT

DOUBLE 2x SPLINEBEVEL CUT

Fig. 22

ROOF-TO-ROOF PANEL CONNECTIONS

VALLEY DETAIL

EXPANSION GAP 1/8"

8d COMMON NAILS@ 6" O.C. EACH PANELAND EACH SIDE

SIP PANEL

BLOCK SPLINE

CONTINUOUS SEALANTEACH SIDE OF FRAMING TYP.AS RECOMMENDED BYMANUFACTURER

Fig. 23

WALL-TO-WALL VERTICAL PANEL CONNECTIONS

BLOCK SPLINE