4
20 6 Rev E 1 Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice. [email protected] www.fulham.com Page 1 of 4 *For further detailed instructions and list of kit components please refer to the Installation Instructions. *Self-Diagnostic Standard. *Self-Diagnostic comes factory disabled. Please reference pg.4 for more details. <4W Input Power To be operated with FHS1-UNV-3.6L only 450 Lumen output Wall Sconce and Ceiling Flush Mount compatible General Specifications Input Current Input Power * Lumen Output * Maximum Output Current Output Voltage Output Short Circuit Protection Recharge Time Required Battery Type Ambient Temperature Surge Protection Warranty 120V - 277V ± 10%, 47-63Hz 0.07A <4W 2.1 Amp. when used with # FHSBATT3-C3 3.6V Self resetting PTC 24 Hrs. UL 1310 / Class 2 C62.41 (TVS) 0°C - 50°C 5 Years 450 Lumens Battery Capacity Available NiCd 3.6VDC Illumination Time Output Classification 3Ah 145 Min. Estimated Run Time Minimum 90 min Low Level Lighting Linear arrays are linkable HotSpot UL Classified Kit components Universal Voltage * Over Current Protection Fuse FHSKITT03LNC 4W HotSpot UL Classified Kit E365124 E493705 BC

FHSKITT03LNC BC2016 Rev E Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FHSKITT03LNC BC2016 Rev E Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice

20 6 Rev E1

Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.Specifications subject to change without notice.

[email protected] www.fulham.com

Page 1 of 4

*For further detailed instructionsand list of kit components pleaserefer to the Installation Instructions.

*Self-Diagnostic Standard.*Self-Diagnostic comes factory disabled. Please reference pg.4 for more details.

• <4W Input Power

• To be operated with FHS1-UNV-3.6L only• 450 Lumen output

Wall Sconce and Ceiling Flush Mount compatible

General Specifications

Input Current

Input Power *Lumen Output * Maximum Output Current Output VoltageOutput Short Circuit Protection

Recharge Time RequiredBattery Type

Ambient Temperature

Surge Protection

Warranty

120V - 277V ± 10%, 47-63Hz

0.07A <4W

2.1 Amp. when used with # FHSBATT3-C3

3.6V Self resetting PTC24 Hrs.

UL 1310 / Class 2

C62.41 (TVS)

0°C - 50°C5 Years

450 Lumens

Battery Capacity AvailableNiCd 3.6VDC

Illumination Time

Output Classification

3Ah

145 Min.Estimated Run TimeMinimum 90 min

Low Level Lighting • Linear arrays are linkable

HotSpot UL Classified Kit components

Universal Voltage *

Over Current Protection Fuse

BC

A

B

C

D

134

D

C

B

A

4 3 2 1

2

DWG NO.SIZE REV

SHEET

PART NO.

SCALE

TITLE

DRAWN

CHKD

CHKD

UNLESS OTHERWISE SPECIFIED

APPROVALS DATE

DO NOT SCALE PRINT

1.0

FROM

1 OF 1THIS DRAWING IS THE PROPERTY OF FULHAM Co., INC AND CONTAINS PRIVILEGED OR CONFIDENTIAL INFORMATION. YOU WILL NOT DISCLOSE, USE, DISSEMINATE, DISTRIBUTE OR COPY THIS DRAWING FOR PURPOSES OTHER THAN WHAT IT IS INTENDED FOR. 4:5

12705 S. Van Ness Ave.Hawthorne, CA 90250 tel.: 1-323-779-2980, fax: 1-323-754-9060

DIMENSIONS ARE IN INCHES

MARCO LOPEZ

KAMRAN SARMADI

10/16/14

B

10/23/14

CHKD

FRONt VIEWLEFT VIEW

9" POLYGON LED ENGINE:TET120023RDXX-01, TET120018RDXX-01TET120023RDXX-11, TET120018RDXX-11TET120023RDXX-02, TET120018RDXX-02TET120023RDXX-12, TET120018RDXX-12

EDWIN REYES 10/23/14

See Title

9.00

2.33

4X0.188 TH

RU

0.8

0

1.30

1.5

0

0.25

Driver

8.00 B.C.

1.26

1.79

OBLIQUE VIEW

REVISIONS

ZONEREV. DESCRIPTION DATE APPROVED

1.0 INITIAL RELEASE

FHSKITT03LNC4W HotSpot UL Classified Kit

E365124E493705

BC

Page 2: FHSKITT03LNC BC2016 Rev E Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice

20 6 Rev E1

Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.Specifications subject to change without notice.

[email protected] www.fulham.com

Page 2 of 4

Part Number Matrix

Mechanical Data

FHSBATT3-C3

1.201.541.64

FHS1-UNV-3.6L

FHS6-AR-3W-L LINEAR MODULE

HOLES: 2 - 0.169" x 0.205" [4.3mm x 5.2mm]

Retrofit TypeT = Troffer

TLED Wattage

03 = 3W

03 KIT

KIT CBattery Type

= C CellC LED Type

LN = Linear

LNFHSProduct Line

FHS = HotSpot

Top View

Top View

Top View

0

.18”

(4.6

mm

)

3.10”(78.77mm)

0.79”(20.12mm)

0

.827”

(21m

m)

1.09”(27.78mm)

0.70”(17.83mm)

4.685” (1198mm)

Side View

Side View

Emergency Driver

Battery

4.24”(107.69mm) 3.69” (93.72mm)

1.99” (50.54mm)

3.10” (78.74mm)

1.06”(26.92mm)

5.34”(135.63mm) 4.97”

(126.24mm)

4.24”(107.69mm)

4.24”(107.69mm)

4.24”(107.69mm)

R0.07”(R1.778mm)

0.81”(20.57mm)

4.67”(118.62mm)

FHSKITT03LNC4W HotSpot UL Classified Kit

E365124E493705

BC

Page 3: FHSKITT03LNC BC2016 Rev E Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice

20 6 Rev E1

Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.Specifications subject to change without notice.

[email protected] www.fulham.com

Page 3 of 4

Wiring Diagram

12 1”+ 12 1”+ 24 1”+

WIRE

LENGTH - INCHES

BLACK WHITE BATTERY- LED ARRAY- TEST SWITCH- PILOT LIGHT

FHSKITT03LNC4W HotSpot UL Classified Kit

E365124E493705

BC

BATTERY LED ARRAY TEST

SWITCH

INPUTPOWER

FRONT VIEW RIGHT VIEW

FHS1-

UNV-3

.6L

WIRING DIAGRAM (TYP)

BLACK

WHITE(COMMON)

HOT( 100V ~ 277V)

BATTERY

TESTSWITCH

LED ARRAY

BLK

RED

IMPORTANT: Do not connect battery until fixture is installed

NOTE: In order to maintain proper operation and warranty coverage, the battery must be recharged once per year prior to installation.

IMPORTANT: Do not connect battery until fixture is installed

NOTE: In order to maintain proper operation and warranty coverage, the battery must be recharged once per year prior to installation.

Page 4: FHSKITT03LNC BC2016 Rev E Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. Specifications subject to change without notice

20 6 Rev E1

Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.Specifications subject to change without notice.

[email protected] www.fulham.com

Page 4 of 4

TEST SWITCH OPERATIONS:

1. EM TEST : Press and hold test button for more than one second to enter EM mode for testing.

2. Manual Self-Diagnostic : After charging the battery for the specified recharge time, quickly press the test button three times within two seconds to force the controller to enter a Self-Diagnostic cycle. To quit the self-diagnostic cycleafter engaged press and hold the test button for ten seconds.

3. Enable/Disable Self-Diagnostic Status : Quickly press the test button two times within two seconds ,the monochromatic lamp displays the status of Self-Diagnostic Enable / Disabled settings.

4. Enable/Disable Auto Self-Diagnostic : Press and hold the test button for two seconds, then release and quickly press the test button two times, then release and press and hold the test button for two more seconds. When properly executed the indicator on the test button will display the flash mode for the Enable/Disable status. A flash of 2.5S on - 0.5S off means "Enabled", while a flash of 0.5S on - 2.5S off means "Disabled", the flashing will last for a few cycles.

LED indicator Status Comment Note

Permanent Red

Light/Solid System OK AC mode

Blinking ON

(4.5 sec on – 0.5 sec off)

Self-diagnose test

underwaySelf-Diagnostic

Blinking OFF

(0.5 sec on – 4.5 sec off)Charge circuit is broken Replace EM Driver

Fast Flashing

(0.5 sec on - 0.5 sec off)Battery not connected Connect battery pack.

Fast Flashing

(0.5 sec on - 0.5 sec off)Battery failure Change the battery

Very Slow Flashing

(4 sec on – 4 sec off)

Over Circuit Protection

Error Triggered.

Check LED load or

check

EM driver.

AC power will need to be

cycled on/off as well as the

battery re-connected

FHS1-UNV-3.6L Status Indication - Single Color Indicator

SELF- DIAGNOSTIC INSTRUCTIONS / OPERATION:

If the self-diagnostic feature is enabled:The emergency LED driver will conduct a self-check for thirty (30) seconds every thirty (30) days; and a ninety (90) minute self-check every 12 months. After every self-check the LED indicator light will indicate a status signal. Check indicator status chart above to diagnose the status signal.

If the self-diagnostic feature is disabled:User must conduct a manual test every thirty (30) days to ensure the emergency LED light source illuminates as intended. A full discharge test shall be conducted once a year; the LED light source shall illuminate for a minimum of ninety (90) minutes.

*Self-Diagnostic feature is factory disabled

Test Switch Indicator Status

FHSKITT03LNC4W HotSpot UL Classified Kit

E365124E493705

BC