8
Contact Information FETCO® Food Equipment Technologies Company 600 Rose Road Lake Zurich IL 60047-0429 USA Internet: www.fetco.com ©2017 Food Equipment Technologies Company Phone: (800) 338-2699 (US & Canada) (847) 719-3000 Fax: (847) 719-3001 Email: [email protected] [email protected] P162 rev000 NEW October, 2017 www.fetco.com User’s Guide and Operator Instructions FETCO Decanter Warmer Station “DUAL” Decanter Warmer Station “SINGLE” Decanter Warmer Station FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

Contact Information

FETCO®

Food Equipment Technologies Company 600 Rose Road Lake Zurich IL 60047-0429 USA Internet: www.fetco.com ©2017 Food Equipment Technologies Company

Phone: (800) 338-2699 (US & Canada)

(847) 719-3000 Fax: (847) 719-3001

Email: [email protected] [email protected]

P162 rev000 NEW October, 2017

www.fetco.com

User’s Guide and Operator Instructions

FETCO Decanter Warmer Station

“DUAL” Decanter Warmer Station

“SINGLE” Decanter Warmer Station

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 2: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

P162 REV:000 October 2017 2

Installation Safety And Hygiene Directions-For International & CE Marked Equipment

1. This appliance is only intended only as a warming device to hold decanters with previously heated contents at serving temperature and is not intended to heat cold decanters to high temperature, or as a “hot plate”.

2. Commercial cooking equipment may be unsafe for household use.

3. Applications include kitchen areas in shops, offices and other professional food-service areas.

4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm.

5. Warming station exterior and decanter warmers are hot—keep hands and other items away.

6. Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the coffee brewer. This appliance must be installed in locations where it can be overseen by trained personnel

7. For proper operation, install this appliance only indoors. It is intended for hot beverage service only.

8. All commercial cooking equipment, including this unit, is not intended for use by children or persons with reduced physical, sensory, or mental capabilities. Ensure proper supervision of children and keep them away from the unit. Children should be supervised to ensure that they do not play with hot beverage equipment.

This unit must be installed, operated and serviced by qualified personnel only.

9. If the power cord requires repair or replacement-it must be performed by the manufacturer or authorized service personnel with the specified cord only from the manufacturer in order to avoid a hazard.

10. The appliance must be disconnected from its power source during service and when replacing parts. During service an operator must be able to check from any position that the plug remains removed. If this is not possible, an electrical disconnection with a locking system in the isolated position shall be provided.

11. Danger of fire or electric shock, do not open panels. No user serviceable parts inside

12. Review the dimensions for the unit and verify that it will fit properly in the space intended for it. 13. The A-weighted sound pressure level is below 70 dB.

14. Unit is for protected indoor use only. Do not steam clean or use excessive water on unit

15. This unit is not “jet-proof” construction. Do not pressure wash or use jet spray to clean this unit.

16. The unit is not waterproof. Do not submerge or saturate with water.

Equipment exposed to flood and contaminated must not be used due to electrical and food safety.

Do not operate if unit has been submerged or saturated with water.

WARMER TEMPERATURE IS NOT ADJUSTABLE

TO START UP A NEW UNIT

INSTALLATION, ADJUSTMENT AND SERVICE THIS SECTION IS FOR PROFESSIONAL USE ONLY!

Remove any protective vinyl film from the stainless-steel enclosure-protective film pulls off.

Locate warming station 1. Place warming station on a solid, level heat-proof counter top, near an electrical outlet. Keep warming station where decanters can be accessed but where they are in a low activity area NOTE: Feet are not for height adjustment

2. Plug unit into outlet.

3. Turn power switch “ON”

Warmer may be left unattended. Coffee quality deteriorates rapidly after brewing, even if unheated. 20 minutes is a good time limit. PTC warmer temperature is self-limiting and will not scorch contents.

CLEANING AND CARE FOR WARMING STATION

1. Turn off and unplug warmer-allow to cool.

2. Wipe warmer plates and surrounding area with a wet clean cloth as required and whenever spills are present.

3. Heat transfer from the warmer plates is most efficient when decanter and warmer plate surface are clean—use only mild detergent and water.

4. Always use a non-abrasive pad, or a wet clean cloth

5. Never use solvents on plastic components—especially cleaners formulated with the solvent diethylene glycol butyl ether (DGBE)

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 3: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

P162 REV:000 October 2017 3

Service Manual – Decanter Warmer Stations

Specifications for FETCO® WARMING STATION Description and Features: A decanter warming station-designed for 64 fl.oz./1.9 L decanters. Heaters are advanced PTC elements which are incapable of overheating coffee PTC heating elements use less energy and self-regulate heating to maintain target liquid temperature

WARMER TEMPERATURE IS NOT ADJUSTABLE Electrical configuration Configuration

Code TYPE Voltage Watts (combined heaters)

Electrical Connection

A153 “SINGLE” 100-120 Volts 150 NEMA 5-15P plug A155 “DUAL” 100-120 Volts 150 NEMA 5-15P plug A154 “SINGLE” 200-240 Volts 130 CEE 7/7 PLUG A156 “DUAL” 200-240 Volts 130 CEE 7/7 PLUG

CE models Electrical configuration A157 “SINGLE” 230 Volts 130 CEE 7/7 PLUG A158 “DUAL” 230 Volts 130 CEE 7/7 PLUG

FETCO warming stations use PTC-Positive Temperature Coefficient heaters that do not overheat or “cook” the coffee as they never attain the high temperature of a conventional coil type heater. The PTC heater will automatically turns off when at set temperature. PTC heaters save energy and provide gentle and consistent temperature control.

Weights and Dimensions WARMER DIMENSIONS AND WEIGHT SHIPPING CARTON DIMENSIONS AND WEIGHT

Model Height Width Depth Weight Height Width Depth Weight

Single 1 3/4 in. 44 mm

16 in. 406 mm

7 1/2 in. 190 mm

4.4 lbs 2 kg

2 1/2 in 88 mm

18 1/2 in 465 mm

11 in 275 mm

5 1/4 lbs 2.4 kg

Dual 6 in

152 mm 16 in.

406 mm 7 1/2 in. 190 mm

5.8 lbs 2.6 kg

8 in 200 mm

19 in 485 mm

9 3/4 in 245 mm

7 lbs 3.2 kg

Allow approximately 30 inch/77cm above counter for standard glass decanter

Dimensions

G

W

NEMA 5-15P Plug Configuration

Export Only 250V 16 A “Schuko" CEE 7/7 PLUG

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 4: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

P162 REV:000 October 2017 4

Ref# Qty Part number Description Parts Drawing Dual Warmer

1 1 1112.00486.00 WELDMENT BODY COMPLETE, WARMER STATION, DUAL LEVEL 2A 2 1102.00322.00 ASSY, WARMER PLATE, 120VAC (USED IN A153 / A155) 2B 2 1102.00355.00 ASSY, WARMER PLATE, 230VAC (USED IN A154 / A156 / A157 / A158) 3 2 1003.00312.00 BRACKET, WARMER TRAY HOLDER 4 4 1083.00004.00 WASHER, M4, 18-8 SS FLAT 5 4 1084.00049.00 NUT, HEX LOCKWASHER, M4x0,7, 18-8 ST. STL. 6 1 1086.00046.00 BUSHING, STRAIN RELIEF, .12"-.58" DIA CABLE 7 2 1023.00263.00 CORNER INSERT FOR BASE 8 2 1046.00050.00 LABEL "CAUTION, HOT SURFACE" 9 2 1058.00046.00 ROCKER SWITCH, RC95 SERIES, 125VAC NEON LAMP 10 2 1029.00006.00 NUT, FINGER, #4-40 NYLON 11 2 1023.00292.00 BRACKET, HOLDING, POWER SWITCH

12A 1 1102.00334.00 ASSEMBLY, POWER CORD, 120VAC w/NEMA 5-15P PLUG 120VAC MODELS ONLY 12B 1 1102.00357.00 ASSEMBLY, POWER CORD, CEE7 EU1-16P PLUG 230VAC MODELS ONLY 13 1 1052.00055.00 TERMINAL BLOCK, 4 CIRCUIT, 20AMPS@600V 14 1 1044.00012.00 LABEL GROUND, CE 15 2 1082.00122.00 SCREW, PHIL. RND. HD., 4-40 x 3/4"LG. 16 1 1001.00367.00 COVER BASE PLATE, WARMER STATION 17 1 1401.00142.00 WIRING, WARMER STATION, L-N-PE 18 4 1082.00017.00 SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG. 19 4 1073.00021.00 FOOT, RUBBER, 1/4-20 20 1 1041.00030.00 LABEL "FETCO", ETCHED GLASS 21 1 1046.00049.00 LABEL, WARNING "ELECTRIC SHOCK OR FIRE", 4x4 22 1 1043.00036.00 TEMPLATE, SN LABEL, FETCO PRODUCTS

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 5: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

P162 REV:000 October 2017 5

Ref# Qty Part number Description Parts Drawing Single Warmer 1 1 1112.00488.00 WELDMENT BASE COMPLETE, WARMER STATION, SINGLE LEVEL

2A 2 1102.00322.00 ASSY, WARMER PLATE, 120VAC (USED IN A153 / A155) 2B 2 1102.00355.00 ASSY, WARMER PLATE, 230VAC (USED IN A154 / A156 / A157 / A158) 3 2 1003.00312.00 BRACKET, WARMER TRAY HOLDER 4 4 1083.00004.00 WASHER, M4, 18-8 SS FLAT 5 4 1084.00049.00 NUT, HEX LOCKWASHER, M4x0,7, 18-8 ST. STL. 6 4 1023.00263.00 CORNER INSERT FOR BASE 7 1 1046.00050.00 LABEL "CAUTION, HOT SURFACE" 8 2 1058.00046.00 ROCKER SWITCH, RC95 SERIES, 125VAC NEON LAMP 9 1 1086.00046.00 BUSHING, STRAIN RELIEF, .12"-.58" DIA CABLE 10 1 1052.00055.00 TERMINAL BLOCK, 4 CIRCUIT, 20AMPS@600V 11 2 1081.00066.00 STANDOFF, #2-56 X 1/8"OD X 3/8"LG, FT, NYLON 6/6 12 1 1083.00011.00 WASHER, #8 SCREW SIZE, INTERNAL TOOTH LOCK 13 1 1084.00006.00 NUT, 8-32 18-8 HEX MACHINE SCREW 14 1 1044.00012.00 LABEL GROUND, CE 15 2 1023.00292.00 BRACKET, HOLDING, POWER SWITCH 16 1 1001.00367.00 COVER BASE PLATE, WARMER STATION 17 1 1401.00142.00 WIRING, WARMER STATION, L-N-PE 18 4 1073.00021.00 FOOT, RUBBER, 1/4-20 19 4 1082.00017.00 SCREW, TRUSS HD. PHIL. MACHINE, # 6-32 X 1/2 LG. 20 1 1041.00030.00 LABEL "FETCO", ETCHED GLASS

21A 1 1102.00334.00 ASSEMBLY, POWER CORD, 120VAC w/NEMA 5-15P PLUG 120VAC MODELS ONLY 21B 1 1102.00357.00 ASSEMBLY, POWER CORD, CEE7 EU1-16P PLUG 230VAC MODELS ONLY 22 1 1043.00036.00 TEMPLATE, SN LABEL, FETCO PRODUCTS 23 1 1046.00049.00 LABEL, WARNING "ELECTRIC SHOCK OR FIRE", 4x4

Drawings 1101.00378.00; 1101.00379.00; 1101.00380.00 1101.00381.00;

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 6: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

P162 REV:000 October 2017 6

Wiring Diagram

Labels for Warming Station

1046.00050.00 Optional Carafe Warmers (X2)

1046.00049.00 Back Panel of Equipment

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 7: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

End of Section Notes:

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE

Page 8: FETCO Decanter Warmer Station4. Use heater setting only for uninsulated glass or metal decanters. Maximum decanter base is 4 ½ inch/115mm. 5. Warming station exterior and decanter

End of Section Notes:

FIRST DRAFT FOR REVIEW ONLY-DO NOT RELEASE