4
► Pro Circuit ► Control SCR ► Rectifier ► SCR Circuit UPS - Rectifier- Inverter www.necron.com.tr +90 (216) 494 0 444 World Power from TURKEI DC Power Supply + Cabinet www.ips-group.net/ All In One, Effitient Power Supply Innovative Cooling

Familiarization With the Reversible DC Power Supply

Embed Size (px)

DESCRIPTION

lll

Citation preview

  • 3/11/2014 Familiarization with the Reversible DC Power Supply

    http://protorit.blogspot.com/2012/11/reversible-dc-power-supply.html 1/4

    Tuesday, March 11. About me Contact Search

    Search

    PROJECT A ND THESIS POWER ELECTRONICS CIRCUIT DIA GRA MS

    Familiarization with the Reversible DC Power Supply12:38 AM // 0 comments // Sajib Barua // Category: EE , Featured , Power Electronics Sessonal //

    DISCUSSION

    The reversible dc power supply

    A reversible dc power supply is a device whose voltage

    and current are reversible. This means that the polarity

    of the voltage across the dc power supply can be either

    positive or negative, and that the current can flow

    through the dc power supply in either direction. F8-1

    shows the symbol to represent a reversible dc power

    supply whose voltage (E) is adjustable. The arrow

    beside letter E in the symbol points towards the

    positive terminal of the reversible dc power supply

    when voltage E is positive.

    F8-1: Symbol representing a reversible dc power supply whose voltage is adjustable.

    F8-2 shows four simple circuits in which a reversible dc power supply is connected to a fixed-voltage dc

    power supply.

    In F8-2(a), the polarity of voltages E and E1 is positive, and the voltage E is greater than the voltage E1.

    Therefore, the current in the circuit (I) flows in the direction shown in F8-2(a). The polarity of this current is

    positive because it flows in the direction indicated by the arrow over the letter I in F8-2(a). therefore, the

    polarity of the voltage E and current I is positive and power flows from the reversible dc power supply t the

    fixed-voltage dc power supply.

    In F8-2(b), the polarity of the voltages E and E1 is still positive, but this time the voltage E is lower than the

    voltage E1. Therefore, the current I flows in the direction shown in F8-2(b). The polarity of this current is

    negative because it flows in the direction opposite to the direction indicated by the arrow over the letter I in

    F8-2(b). Therefore, the polarity of the voltage E is positive, the polarity of the current I is negative, and

    power flows from the fixed-voltage dc power supply to the reversible dc power supply.

    Home

    Go

    Subscribe to EngineeringResources

    Receive New Articles As They are Posted

    RECENT POSTS RECENT COMMENTS

    Single-phase half-bridge neut...

    05-Jan-2014

    Conventional three-phase six-...

    01-Jan-2014

    Single-phase full-bridge VSC...

    06-Apr-2013

    Single-phase half-bridge VSC...

    27-Mar-2013

    Voltage-source converters (VS...

    25-Mar-2013

    GOOGLE+ FOLLOWER S

    EEE

    16 have us incircles

    Viewall

    Follow

    Pro Circuit Control SCR Rectifier SCR Circuit

    UPS - Rectifier- Inverterwww.necron.com.tr

    +90 (216) 494 0 444 World Power from TURKEI

    DC Power Supply+ Cabinetwww.ips-group.net/

    All In One, Effitient Power

    Supply Innovative Cooling

  • 3/11/2014 Familiarization with the Reversible DC Power Supply

    http://protorit.blogspot.com/2012/11/reversible-dc-power-supply.html 2/4

    F8-2: Simple circuits using a reversible dc power supply.

    In F8-2(c), the voltage E has been adjusted so that its polarity is negative and the connections of the fixed-voltage power supply have been

    reversed so that the polarity of the voltage E1 is also negative. Furthermore, the voltage E is lower than the voltage E1. For example, the voltage

    E and E1 could be equal to -30 and -20 V, respectively. Therefore, the current I flows in the direction shown in F8-2(c). The polarity of this

    current is negative because it flows in the direction opposite to the direction indicated by the arrow over the letter I in F8-2(c). Therefore, the

    polarity of the voltage E and current I is negative and power flows from the reversible dc power supply to the fixed-voltage dc power supply.

    In F8-2(d), the polarity of the voltage E and E1 is still negative, but this time the voltage E is greater than the voltage E1. For example, the

    voltage E and E1 could be equal to 10 and 20 V, respectively. Therefore, the current I flows in the direction shown in F8-2(d). The polarity of

    this current is positive because it flows in the direction indicated by the arrow over the letter I in F8-2(d). Therefore, the polarity of the voltage

    E is negative, the polarity of the current I is positive, and power flows from the fixed-voltage dc power supply to the reversible dc power

    supply.

    F8-3 is a four-quadrant diagram of the current I versus the voltage E which summarizes the operation of the dc power supply. Dot A in this

    diagram represents the voltage E and current I related to the reversible dc power supply in F8-2(a), dot B represents the voltage E and the

    current I related to the reversible dc power supply in F8-2(b) and so on. This figure shows that the reversible dc power supply can operate in

    either one of the four quadrants. For each quadrant, the figure indicates whether the reversible dc power supply sources or sink power.

    F8-3: Four-quadrant diagram summarizing the operation of reversible dc power supply.

    In brief, current can flow in either direction in the reversible dc power supply regardless the polarity of the voltage across the reversible dc

    power supply. Furthermore, the reversible dc power supply can either source or sink power.

    Implementing a reversible dc power supply

    A reversible dc power supply can be implemented using a separately-exited dc motor/generator mechanically coupled to a synchronous or

    asynchronous motor/generator. F8-4 shows a reversible dc power supply in which the separately-excited dc motor/generator is coupled to a

    three-phase squirrel-cage induction motor (asynchronous motor).

    FOLLOWER S

    FEEDJIT

    Join this sitew ith Google Friend Connect

    Members (13)

    Already a member? Sign in

    Visitors

    Share 2

    About Me

    Sajib Barua

    Follow 93

    View my complete profile

    LabelsCircuit Diagrams

    DC to AC Converters

    DC-DC CONVERTERS

    EE

    Electromagnetic Field Sessional

    Featured

    3 5 2 8 2 2

    Live Traffic Feed

    Real-time view Menu

    A visitor from Rawalpindi, Punjab viewed"Familiarization with the Reversible DC

    Power Supply" 4 mins agoA visitor from Sobtka, Dolnoslaskieviewed "GATE PULSESGENERATION FOR VARIOUS

    POWER ELECTRONICSCONVERTERS" 28 mins agoA visitor from Konya left "3-Phase

    Voltage Source Inverter With SquareWave Output" via protorit.blogspot.com39 mins agoA visitor from Konya viewed "3-PhaseVoltage Source Inverter With Square

    Wave Output" 39 mins agoA visitor from Glasgow, Glasgow City

    viewed "MODELING OF A WIND

    TURBINE GENERATOR USINGWIND SPEED AS A CONTROLLEDVARIABLE" 1 hr 9 mins agoA visitor from Bangkok, Krung Thepviewed "Three-phase half-waveControlled Rectifier" 1 hr 20 mins agoA visitor from Kazan, Tatarstan viewed

    "Power Electronics Systems Applications

    and Resources on Electrical and

    Electronic Project-Thesis" 1 hr 36 mins

    agoA visitor from Kastamonu viewed "GTO"

    2 hrs 8 mins agoA visitor from Kurnool, Andhra Pradesh

    viewed "GATE PULSES

    GENERATION FOR VARIOUSPOWER ELECTRONICS

    CONVERTERS" 5 hrs 2 mins agoA visitor from Kirkuk, At Tamim viewed

    "Three-phase half-wave ControlledRectifier" 5 hrs 7 mins ago

  • 3/11/2014 Familiarization with the Reversible DC Power Supply

    http://protorit.blogspot.com/2012/11/reversible-dc-power-supply.html 3/4

    FREQUENCY CHARACTERISTICS OF LINE

    MEASURING THE ATTENUATION OF A LINE

    MEASURING THE CHARACTERISTICS OF A LINE

    One-cycle control for Bulk-converter

    Familiarization with the Reversible DC Power Supply

    Familiarization with the IGBT Chopper/Inverter module

    Single-phase half-bridge neutral-point-clamped (NPC) VSC

    Conventional three-phase six-step VSC

    Single-phase full-bridge VSC

    Single-phase half-bridge VSC

    Switching transients in the general case

    Switching transients and the concept of transient-free switching

    The thyristor-switched capacitor (TSC)

    The thyristor-controlled transformer (TCT)

    Thyristor-controlled equipment

    Thyristor Three-Phase, Six-Pulse Converter (PROCEDURE)

    Thyristor Three-Phase, Six-Pulse Converter

    Thyristor Single-Phase Bridge Rectifier/Inverter (PROCEDURE)

    Rectifier and inverter modes

    Bridge rectifier with two thyristors and two diodes

    0 COMMENTS FOR THIS POST

    F8-4: A reversible dc power supply implemented with a separately-excited dc motor/generator and an

    asynchronous motor.

    The output of the reversible dc power supply is taken across the armature circuit of the separately-excited dc

    motor generator. The polarity and value of the armature voltage, and therefore, the polarity and value of the

    voltage E provided by the reversible dc power supply depends on the polarity and value of the current

    flowing in the exciting coil of the dc motor/generator and the rotation speed of the dc motor/generator. The

    rotation speed of the dc motor/generator is equal to the rotation speed of the asynchronous motor, which

    varies little. Therefore, the polarity and value of the voltage E provided by the reversible dc power supply

    especially depends on the polarity and value of the current flowing in the exciting coil of the dc

    motor/generator.

    The current flowing in the exciting coil of the dc motor /generator depends on the voltage provided by a fixed-voltage dc power supply and

    tandem rheostats. The tandem rheostats are rheostats which share a single shaft. The tandem rheostats allows the voltage applied to the exciting

    coil is Ex. On the other hand, the voltage applied to the exciting coil is Ex when the cursors are set to the lower end of the rheostats.

    The direction of the current flowing in the armature circuit, and therefore, the direction of the current I flowing in reversible dc power supply

    depends on whether the dc motor/generator source or sinks power. When the dc motor/generator sources power, the squirrel-cage induction

    motor drives the dc motor/generator which operates as a generator. Conversely, when the dc motor/generator sinks power, it operates as a

    motor and drives the squirrel-cage induction motor which operates as a generator and provides power to the ac power supply.

    Related posts :

    Inventory Management

    Power Electronic Converter

    Power Electronics

    Power Electronics Sessonal

    Power Supply

    Project and Thesis

  • 3/11/2014 Familiarization with the Reversible DC Power Supply

    http://protorit.blogspot.com/2012/11/reversible-dc-power-supply.html 4/4

    LEAVE A REPLY

    Please wait for approval of your comment .......

    Enter your comment...

    Comment as: Google Account

    Publish

    Preview

    OLDER POST NEWER POST

    FOLLOW BY EMA IL

    Home About me Contact RSS

    Email address... Submit