2977 Fircrest Dr SE, Port Orchard, WA 98366
September 15, 2017 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.
You may view more detailed information for this home and can make an offer at
http://www.faira.com/listings/11510 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
Inspection Report for Mrs. Alicia PearsonProperty Address: 2977 Fircrest Dr SE, Port Orchard, Washington 98366
NW WASHINGTON HOME INSPECTIONS LLC
Carl Liberman WA License # 1758 Bainbridge Island, WA
Table of Contents
Cover Page.................................................................1
Table of Contents ........................................................2
Intro Page ...................................................................3
Significant Issues ........................................................5
Repair & Maintenance Summary ................................6
Complete Wood Destroying Organism InspectionReport .......................................................................10
1 Roof .......................................................................12
2 Attic ........................................................................19
3 Exterior...................................................................20
4 Wall Exteriors.........................................................25
5 Structure ................................................................27
6 Electrical ................................................................32
7 Garage...................................................................36
8 Interior....................................................................39
9 Plumbing ................................................................41
10 Heating.................................................................45
11 Bathrooms............................................................47
12 Kitchen and Built-in Appliances ...........................49
13 Laundry Room .....................................................51
Invoice.......................................................................53
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 2 of 53
Date: 9/18/2017 Time: 02:00 PM Report ID: 170918 B / ICN10246AR003
Property:2977 Fircrest Dr SEPort Orchard Washington 98366
Customer:Mrs. Alicia Pearson
Real Estate Professional:Chris EllisFaira.com
Dear Mrs. Pearson,
Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.
Two summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. The results of your Structural Pest Inspection are also summarized in the Complete WoodDestroying Organism Inspection Report, also included at the beginning of the Home Inspection Report.
The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.
If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at [email protected]. I look forward to providing future home inspection needs to you, yourfriends, and family.
Warm Regards,
Carl Liberman
Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.
Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
Wood Destroying Organisms ( ) = Items or discoveries that indicate the presence of wood destroying organisms orconditions conducive to wood destroying organisms. Conducive conditions include but are not limited to, inadequateclearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture.
Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence ofpests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 3 of 53
respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine theeffectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Type of building::Single Family (2-story)
Approximate Square Footage::1800
Approximate Year of OriginalConstruction::1991
Inspection started at::2pm
Inspection ended at::4:30pm
Occupancy::Unoccupied, empty of furniture
Attending the Inspection::Seller
Weather during the Inspection::Light Rain
Significant precipitation in last 3 days::Yes
Temperature during inspection::Over 60 (F) = 15.5 (C)
Ground/Soil surface condition:Wet
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 4 of 53
Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.
1. Roof
1.0 Roof Structure Exterior(1) Roof soffits are in need of preservation & painting around the entire house. Recommend contacting a licensedpainting contractor for options and costs.
3. Exterior
3.6 Deck, Balcony, Bridge and Porch,(1) This 2nd story porch is cantilever and appears to exceed it's allowed overhang based on joist size and spacing(2X8 24 inches on center). Please see http://www.awc.org/codes-standards/publications/dca6 for furtherinformation. I would recommend modifications to the structure to comply with current deck safety standards. Pleaseconsult a licensed decking contractor and/or a licensed structural engineer for options and costs.
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 5 of 53
Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
1. Roof
1.0 Roof Structure Exterior(2) A noticeable sag in the roofline was observed were the upper roof meets the lower roof at the overhang.
(3) Heavy moss and algae build-up were observed on the lower side-roof and lighter build-up on the upper backroof. I would recommend treatment to prevent damage to the asphalt shingles.
1.2 Roof FlashingDrip flashing is not installed at the edge of the roofline where the sheathing meets the gutters. Drip flashing protectsthe roof sheathing from water absorption from below. Consider adding drip edge flashing in the future or inconjunction with the next roofing job.
1.5 Chimney at Roof(1) Vent piping for gas appliances in garage has two areas of rust and holes have developed. Recommendreplacement of this section of piping. Recommend repairs by a licensed heating contractor.(2) Chimney siding requires cleaning. Metal cap is missing fasteners.
1.6 Skylight ExteriorsSkylight glass seal has failed. Glass replacement is necessary to restore visual clarity.
3. Exterior
3.2 WalkwaysSettlement of the sidewalk has resulted in a differential height between the two sections of sidewalk posing apotential trip hazard. Consider replacing the section of sidewalk or having it raised.
3.3 General GroundsOld retaining wall has rotted in place. Recommend removal and replacement. These conditions are furtherconducive to wood destroying organisms.
3.6 Deck, Balcony, Bridge and Porch,(2) The ledger board on the side-deck is not properly installed or flashed. Please see http://www.awc.org/codes-standards/publications/dca6 for ledger installation details. Recommend correction by a licensed decking contractor.
3.7 Exterior StairsConsider adding a hand-rail to the entry at the front door for additional safety.
4. Wall Exteriors
4.0 Door ExteriorsFront door latch plate requires securing.
4.2 Exterior Wall Penetrations
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 6 of 53
Vent (located in eave on back deck) is missing it's flapper door. Recommend replacement.
4.4 Fiber-cementInsufficient clearance to grade exists in this area. Recommend 2 inches minimum to bottom of siding. Resultinggrading should allow for water to drain away from the foundation naturally. These conditions are conducive towood destroying organisms.
5. Structure
5.2 Insulation Under Floor System(1) Insulation in floor bays has been disturbed by a previous rodent problem. Recommend replacement andsecuring of the insulation affected throughout the crawlspace. Recommend continued setting of traps for rodents aspreventative measure.(2) Section of water main requires insulation.
5.3 FoundationRemaining foundation wood forms are in contact with the soil and are rotting. These conditions are furtherconducive to wood destroying organisms.
5.4 Crawlspace(1) Crawlspace vents around the perimeter of the home require cleaning to maintain function.
5.5 Crawl Space Moisture ConditionsStaining of the moisture barrier indicate signs of past standing water in the crawlspace. Conditions were dry duringinspection. I would recommend further monitoring and remediation if problem is found during wet season.
6. Electrical
6.6 Service Panel ManufacturerThe service panel was made by Westinghouse. Westinghouse service panels are reputed to have a high rate ofcircuit breaker failure. I would recommend further inspection by a licensed electrician.
6.21 Carbon Monoxide DetectorsCarbon monoxide alarms must be located outside of each separate sleeping area, in the immediate vicinity of thebedroom and on each level of the residence. Install in accordance with manufactures recommend guidance or hire alicensed contractor for proper installation.
Reference WAC 51-51-315: http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
7. Garage
7.1 Conventional Doors(1) Side garage door does not close properly. Weather-stripping is damaged. Recommend repairs by a licensedcontractor.(2) Recommend weather-stripping replacement and the addition of a self-closing hinge to the door from the garageto the home.
7.9 AtticInsulation is disturbed in the attic above the garage by rodents. Recommend clean-up and insulation replacement.Recommend taking measures to eliminate or prevent the return of rodents.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 7 of 53
8. Interior
8.5 DoorsStrike-plate missing for the pocket door in the master bathroom.
9. Plumbing
9.1 Source of Water(1) Water pressure was very high measured at 95 psi. Pressure regulation is recommended for when waterpressure exceeds 80 psi, optimal water pressure is 40 - 70 psi. I would recommend contacting the water providerand further inquiring. A pressure regulation valve can be installed to reduce water-pressure within the home ifnecessary, consult a licensed plumbing contractor.
9.3 Sewage and DWV SystemsA small leak was noted to waste water piping in the crawl-space in the corner nearest the access from outside. Theexact location of the leak was not determined. I would recommend repairs by a licensed plumber.
9.4 Gas Water Heater(1) Seismic straps are required on the hot water tank in the garage. Consider adding a surge tank for additionalsystem protection (now required with new hot water tank installations). I was not able to establish the age of thehot-water heater. Typical life expectancy is 12 -18 years.(2) Gas piping is unsupported. Recommend strapping by a licensed contractor.
10. Heating
10.1 FurnaceFurnace has a build-up of combustion products leaking from joints in the exhaust piping. Recommend sealing of theexhaust piping, cleaning, and servicing by a licensed heating contractor.
10.4 Filter conditionAir filter is dirty and requires replacement.
10.5 FireplaceFireplace flue is dirty and requires cleaning. Consider having the chimney swept by a chimney contractor.
11. Bathrooms
11.11 BathtubStopper for the bathtub is missing.
12. Kitchen and Built-in Appliances
12.9 CabinetsDownstairs bathroom sink cabinet is damaged.
12.13 DishwasherThe dishwasher did not appear to have an anti-siphon device installed in the drain line. Anti-siphon devices areinstalled to prevent wastewater from the dishwasher from being siphoned back into the dishwasher andcontaminating its contents. The Inspector recommends an anti-siphon device be installed by a qualified technician.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 8 of 53
13. Laundry Room
13.9 WasherWashing machine water supply valve is leaking by. Recommend repairs by a licensed plumber.
13.10 DryerElectrical outlet requires a cover-plate. I would recommend adding a cap to the gas line until it is hooked up to aappliance.
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 9 of 53
Complete Wood Destroying Organism Inspection ReportComplete Wood Destroying Organism Inspection Report: This report identifies the presence of wood destroyingorganisms or conditions conducive to wood destroying organisms. Conducive conditions include but are not limited to,inadequate clearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture. PestInspection Standards in Washington State, WAC 16-228-2045 - requires that a diagram / drawing be prepared forwood destroying organism (WDO) Reports. If the photos and descriptions in this report are inadequate, a drawingis available upon request.
WSDA ICN # 10246AR003
_________________________________________________________________________________________________________
Summary of Findings:
Visible Evidence of Active Wood Destroying Insects: None Noted / Present
Visible Evidence of Inactive Wood Destroying Insects: None Noted / Present
Visible Evidence of Active Wood Decaying Fungi: None Noted / Present
Visible Evidence of Damage by Wood Destroying Organisms: None Noted / Present
Visible Evidence of Conditions Conducive to Wood Destroying Organisms: None Noted / Present
_________________________________________________________________________________________________________
Moisture Meter Testing: Where moisture meter testing is indicated in this report a GE Protimeter BLD5365 SurveymasterDual-Function Moisture Meter was used.
Standard Limitations: Complete WDO inspections will identify conditions present at a subject property at the time of an inspection. Inspectorsare not required to report on any WDO infestation or other condition that might be subject to seasonal constraints or environmental condition ifevidence of those constraints or conditions is not visible at the time of inspection. Please note that most WDO observations are related to highmoisture conditions that could be conducive to mold-like substances. NORTHWEST WASHINGTON HOME INSPECTIONS LLC is not a moldspecialist and recommends consulting with an industrial hygienist or other mold remediation expert if concerned about mold or indoor airquality.
3. Exterior
3.3 General GroundsOld retaining wall has rotted in place. Recommend removal and replacement. These conditions are furtherconducive to wood destroying organisms.
4. Wall Exteriors
4.4 Fiber-cementInsufficient clearance to grade exists in this area. Recommend 2 inches minimum to bottom of siding. Resultinggrading should allow for water to drain away from the foundation naturally. These conditions are conducive towood destroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 10 of 53
5. Structure
5.3 FoundationRemaining foundation wood forms are in contact with the soil and are rotting. These conditions are furtherconducive to wood destroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 11 of 53
1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.
Styles & Materials
Method of inspection:Walked the roof
The roof style was:Gable
Primary roof-covering type:3-tab Fiberglass Asphalt Shingle
Drainage system description:Gutters and downspouts installed
Chimney flue material:Metal
Underlayment/Interlayment::Mostly hidden from viewBlack Felt
Sky Light(s):Two
Items
1.0 Roof Structure ExteriorComments: Inspected
(1) Roof soffits are in need of preservation & painting around the entire house. Recommend contacting alicensed painting contractor for options and costs.
1.0 (1)
1.0 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 12 of 53
1.0 (3)
1.0 (4)
(2) A noticeable sag in the roofline was observed were the upper roof meets the lower roof at theoverhang.
1.0 (5) 1.0 (6)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 13 of 53
1.1 UnderlaymentComments: Inspected
1.2 Roof FlashingComments: Inspected
(3) Heavy moss and algae build-up were observed on the lower side-roof and lighter build-up on theupper back roof. I would recommend treatment to prevent damage to the asphalt shingles.
1.0 (7) 1.0 (8)
1.0 (9)
Most underlayment was hidden beneath the roof-covering material. The inspector was able to view edges onlya representative areas around the perimeter of the roof.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 14 of 53
1.3 Roof Drainage SystemComments: Inspected
1.4 Plumbing and Combustion VentsComments: Inspected
1.5 Chimney at RoofComments: Inspected
Drip flashing is not installed at the edge of the roofline where the sheathing meets the gutters. Dripflashing protects the roof sheathing from water absorption from below. Consider adding drip edge flashing inthe future or in conjunction with the next roofing job.
1.2 (1) 1.2 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 15 of 53
1.6 Skylight ExteriorsComments: Inspected
(1) Vent piping for gas appliances in garage has two areas of rust and holes have developed.Recommend replacement of this section of piping. Recommend repairs by a licensed heating contractor.
1.5 (1)
1.5 (2)
(2) Chimney siding requires cleaning. Metal cap is missing fasteners.
1.5 (3) 1.5 (4)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 16 of 53
1.7 Asphalt Composition ShingleComments: Inspected
Skylight glass seal has failed.Glass replacement is necessary torestore visual clarity.
1.6 (1)
Views of asphalt shingle roof.
1.7 (1) 1.7 (2)
1.7 (3)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 17 of 53
The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 18 of 53
2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).
Styles & Materials
Attic info:Scuttle hole
Attic inspected from:Inside the attic
Attic thermal insulation material:Blown-in Fiberglass
Approximate attic thermal insulationdepth:
R-19 or better
Roof Structure Ventilation:Attic ventilation appeared sufficient
Roof structure ventilation device type:Roof ventsSoffit vents
Roof Framing Type:Manufactured Roof Trusses
Roof Sheathing Material:PlywoodOriented Strand Board (OSB)
Items
2.0 Attic AccessComments: Inspected
2.1 Roof Framing (from attic)Comments: Inspected
2.2 Roof SheathingComments: Inspected
2.3 Roof Structure VentilationComments: Inspected
2.4 Attic ElectricalComments: Inspected
2.5 Venting Systems (Kitchens, Baths and Laundry)Comments: Inspected
2.6 Ventilation Fans and Thermostatic Controls in AtticComments: Inspected
2.7 Attic Rodent ActivityComments: Inspected
The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 19 of 53
3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Driveway Material:Concrete
Walkway Materials:Concrete
Appurtenance:BalconyDeck
Downspout Discharge:Below Grade
Lot Description:Moderate Slope
Clearance to Grade:Non-Standard
Items
3.0 Exterior ViewsComments: Inspected
3.1 DrivewayComments: Inspected
3.2 WalkwaysComments: Inspected
Some cracking and degradation ofthe concrete driveway is noted.
3.1 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 20 of 53
3.3 General GroundsComments: Inspected
3.4 Exterior TrimComments: Inspected
3.5 PorchComments: Inspected
3.6 Deck, Balcony, Bridge and Porch,Comments: Limitation
Settlement of the sidewalk hasresulted in a differential heightbetween the two sections of sidewalkposing a potential trip hazard.Consider replacing the section ofsidewalk or having it raised.
3.2 (1)
Old retaining wall has rottedin place. Recommend removal andreplacement. These conditions arefurther conducive to wood destroyingorganisms.
3.3 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 21 of 53
(1) This 2nd story porch iscantilever and appears to exceed it'sallowed overhang based on joist sizeand spacing (2X8 24 inches oncenter). Please seehttp://www.awc.org/codes-standards/publications/dca6 for furtherinformation. I would recommendmodifications to the structure tocomply with current deck safetystandards. Please consult a licenseddecking contractor and/or a licensedstructural engineer for options andcosts.
3.6 (1)
(2) The ledger board on the side-deck is not properly installed or flashed. Please see http://www.awc.org/codes-standards/publications/dca6 for ledger installation details. Recommend correction by a licenseddecking contractor.
3.6 (2) 3.6 (3) lag screws not tightened
3.6 (4) non-galvanized ledger bolts 3.6 (5) exposed flashing
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 22 of 53
3.7 Exterior StairsComments: Inspected
3.6 (6) hangers not properly secured
(3) Please note, I was unable toverify the flashing detail for the reardeck ledger board.
3.6 (7)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 23 of 53
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
Consider adding a hand-rail tothe entry at the front door foradditional safety.
3.7 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 24 of 53
4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Exterior wall-covering Material:Fiber-cement Siding
Exterior Doors:Hollow coreFiberglass
Items
4.0 Door ExteriorsComments: Inspected
4.1 Window ExteriorsComments: Inspected
4.2 Exterior Wall PenetrationsComments: Inspected
Front door latch plate requiressecuring.
4.0 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 25 of 53
4.3 Exterior Wall MembraneComments: Inspected
4.4 Fiber-cementComments: Inspected
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
Vent (located in eave on backdeck) is missing it's flapper door.Recommend replacement.
4.2 (1)
Insufficient clearance tograde exists in this area. Recommend2 inches minimum to bottom of siding.Resulting grading should allow forwater to drain away from thefoundation naturally. Theseconditions are conducive to wooddestroying organisms.
4.4 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 26 of 53
5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.
Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.
Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.
Styles & Materials
Typical Ceiling Structure:Drywall attached to dimensional lumber
ceiling joistsDrywall attached to roof trusses
Exterior Wall Structures:Wood Frame
Wall Insulation:Not Visible
Foundation Configuration:Crawlspace
Foundation Method/Materials:Poured concrete foundation walls
% Foundation Not Visible:50%
Main Floor Structure:Oriented strand board (OSB) sheathing
over wood joists
Main Floor Structure- Perimeter Bearing:Rests on top of foundation wall
Main Floor Structure- IntermediateSupport:
Wood beam girderWood postsConcrete Piers
Floor System Insulation:BattsFiberglass
Evidence of Seismic Protection:None Noted
Crawl Space Vapor Barrier:6 Mil Poly
Items
5.0 Exterior Wall ConstructionComments: Inspected
5.1 Floor StructureComments: Inspected
5.2 Insulation Under Floor SystemComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 27 of 53
5.3 FoundationComments: Inspected
(1) Insulation in floor bays has been disturbed by a previous rodent problem. Recommend replacementand securing of the insulation affected throughout the crawlspace. Recommend continued setting of traps forrodents as preventative measure.
5.2 (1) 5.2 (2)
(2) Section of water mainrequires insulation.
5.2 (3)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 28 of 53
5.4 CrawlspaceComments: Not Inspected
Remaining foundation woodforms are in contact with the soil andare rotting. These conditions arefurther conducive to wood destroyingorganisms.
5.3 (1)
(1) Crawlspace vents around the perimeter of the home require cleaning to maintain function.
5.4 (1) 5.4 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 29 of 53
5.5 Crawl Space Moisture ConditionsComments: Inspected
(2) Extensive additional storage structures have been added in the crawlspace. Please note, I am unable toevaluate conditions below or behind these structures as there is inadequate clearance for inspection.
5.4 (3) 5.4 (4)
5.4 (5)
Staining of the moisture barrierindicate signs of past standing waterin the crawlspace. Conditions weredry during inspection. I wouldrecommend further monitoring andremediation if problem is found duringwet season.
5.5 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 30 of 53
5.6 Crawl Space Rodent ActivityComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 31 of 53
6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.
The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting
Styles & Materials
Electrical Service Conductors:Underground serviceAluminum120/240 volt service
Service Panel Ampacity:200 amps
Service Panel Type:Load Center
Service Panel Manufacturer:Westinghouse
Service Disconnect Location:At Service Panel
Service Disconnect Type:Breaker
Service Grounding Electrode:Not Visible
Wiring Methods:Romex
Type of Branch Wiring:Solid CopperStranded Aluminum
Ground Fault Circuit Interruptor (GFCI)Protection:
Partial
Arc Fault Circuit Interruptor (AFCI)Protection:
NO
Items
6.0 General Electrical System DescriptionComments: Inspected
6.1 General Electrical System ConditionComments: Inspected
6.2 Service Drop, Drip Loop, Splice and AttachmentComments: Inspected
6.3 Mast & WeatherheadComments: Inspected
6.4 Electric MeterComments: Inspected
6.5 Service Entrance ConductorsComments: Inspected
6.6 Service Panel ManufacturerComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 32 of 53
6.7 Service Panel Exposure RatingComments: Inspected
6.8 Service Panel Cabinet, Ampacity, and CoverComments: Inspected
6.9 Service Panel WiringComments: Inspected
6.10 Service DisconnectComments: Inspected
6.11 Overcurrent Protection DevicesComments: Inspected
6.12 Service Grounding Electrode System & Service BondComments: Inspected
6.13 Equipment Grounding & BondingComments: Inspected
6.14 Exterior Electrical ReceptaclesComments: Inspected
6.15 Conventional Electrical Receptacles (interior)Comments: Inspected
The service panel was made byWestinghouse. Westinghouse servicepanels are reputed to have a high rateof circuit breaker failure. I wouldrecommend further inspection by alicensed electrician.
6.6 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 33 of 53
6.16 GFCI/AFCI Electrical ReceptaclesComments: Inspected
6.17 SwitchesComments: Inspected
6.18 LightingComments: Inspected
6.19 Visible Branch WiringComments: Inspected
6.20 Smoke DetectorsComments: Inspected
6.21 Carbon Monoxide DetectorsComments: Inspected
Smoke detectors are recommended on each floor of the home, in each bedroom of the home, outsidecommon bedroom areas. Install in accordance with manufactures recommend guidance or hire a licensedcontractor for proper installation.
Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040
Carbon monoxide alarms mustbe located outside of each separatesleeping area, in the immediatevicinity of the bedroom and on eachlevel of the residence. Install inaccordance with manufacturesrecommend guidance or hire alicensed contractor for properinstallation.
Reference WAC 51-51-315:http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
6.21 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 34 of 53
The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 35 of 53
7. GarageInspection of the garage typically includes examination of the following:general structure; floor, wall and ceiling surfaces; operation of all accessibleconventional doors and door hardware; vehicle door condition and operation proper electrical condition including Ground Fault Circuit Interrupter(GFCI) protection; interior and exterior lighting; stairs and stairways proper firewall separation from living space; and proper floor drainage
Styles & Materials
Garage Vehicle Door Type:Double
Number of Vehicle Doors:1
Number of Automatic Openers:1
Vehicle Door Automatic Reverse:Installed and operating correctly
Auto-opener Manufacturer:LIFT-MASTER
Items
7.0 Vehicle DoorsComments: Inspected
7.1 Conventional DoorsComments: Inspected
(1) Side garage door does not close properly. Weather-stripping is damaged. Recommend repairs by alicensed contractor.
7.1 (1) 7.1 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 36 of 53
7.2 FloorsComments: Inspected
7.3 WallsComments: Inspected
7.4 CeilingComments: Inspected
7.5 Fire SeparationComments: Inspected
7.6 Stairs/Steps to Living SpaceComments: Inspected
7.7 Garage ElectricalComments: Inspected
7.8 General Condition and VentilationComments: Inspected
7.9 AtticComments: Inspected
(2) Recommend weather-stripping replacement and the addition of a self-closing hinge to the door fromthe garage to the home.
7.1 (3)
7.1 (4)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 37 of 53
7.10 Roof FramingComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
Insulation is disturbed in the attic above the garage by rodents. Recommend clean-up and insulationreplacement. Recommend taking measures to eliminate or prevent the return of rodents.
7.9 (1) 7.9 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 38 of 53
8. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.
Styles & Materials
Walls and Ceilings:Drywall
Floor Covering Materials:CarpetTileWood
Interior Doors:Hollow
Window Material:Vinyl
Window Glazing:Double-pane
Window Operation:Single-hung
Smoke/CO Detectors:Smoke detectors installed (battery type)Carbon monoxide detector(s) installed
Items
8.0 FloorsComments: Inspected
8.1 WallsComments: Inspected
8.2 CeilingsComments: Inspected
8.3 LightingComments: Inspected
8.4 Misc. Components: Ceiling fans, doorbells, Env. Hazards, Detectors, etc.Comments: Inspected
8.5 DoorsComments: Inspected
Strike-plate missing for thepocket door in the master bathroom.
8.5 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 39 of 53
8.6 Windows and SkylightsComments: Inspected
8.7 Interior TrimComments: Inspected
8.8 Cabinets and CountertopsComments: Inspected
8.9 StairsComments: Inspected
8.10 Bathroom and Laundry VentilationComments: Inspected
The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 40 of 53
9. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).
Styles & Materials
Water Supply Source:Public Water Supply
Main Water Supply Pipe:1-inchCopper
Main Water Supply Location:Garage
Water Distribution Pipes:1/2-inch and 3/4-inch copper
Distribution Pipe Bonding:Pipes were bonded
Sewage System Type:Public
Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)
Water Heater Manufacturer:Kenmore
Date of Manufacture:1991
Water Heater Fuel Type:Gas
Water Heater Type:Tank (conventional)
Water Heater Tank Capacity:50 gallons
Water Heater Location:Garage
Washer Drain Size:2" Diameter
Gas Pipe Material:Black Steel
Type of Gas:Natural Gas
Items
9.0 Exterior PlumbingComments: Inspected
9.1 Source of WaterComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 41 of 53
9.2 Water Supply and DistributionComments: Inspected
9.3 Sewage and DWV SystemsComments: Inspected
(1) Water pressure was very highmeasured at 95 psi. Pressureregulation is recommended for whenwater pressure exceeds 80 psi,optimal water pressure is 40 - 70 psi.I would recommend contacting thewater provider and further inquiring. Apressure regulation valve can beinstalled to reduce water-pressurewithin the home if necessary, consult alicensed plumbing contractor.
9.1 (1)
(2) Please note water cut-off valve ingarage.
9.1 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 42 of 53
9.4 Gas Water HeaterComments: Limitation
A small leak was noted to waste water piping in the crawl-space in the corner nearest the access fromoutside. The exact location of the leak was not determined. I would recommend repairs by a licensedplumber.
9.3 (1) wet area 9.3 (2)
(1) Seismic straps are requiredon the hot water tank in the garage.Consider adding a surge tank foradditional system protection (nowrequired with new hot water tankinstallations). I was not able toestablish the age of the hot-waterheater. Typical life expectancy is 12-18 years.
9.4 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 43 of 53
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(2) Gas piping is unsupported.Recommend strapping by a licensedcontractor.
9.4 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 44 of 53
10. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).
Styles & Materials
Heating System Type:Gas-fired Furnace (medium efficiency)
Energy Source:Natural gas
Number of Heat Systems (excludingwood):
One
Heating/Cooling Ducts:Insulated
Air Filter:Disposable
Air Filter Location:Behind removable panel at furnace
Heating System Brand:Kenmore
Types of FIreplaces:Conventional
Operational Fireplaces:One
Number of Woodstoves:None
Items
10.0 Presence of installed heat source in each roomComments: Inspected
10.1 FurnaceComments: Inspected
10.2 Fuel, Piping and SupportComments: Inspected
10.3 ThermostatComments: Inspected
10.4 Filter conditionComments: Inspected
Furnace has a build-up ofcombustion products leaking fromjoints in the exhaust piping.Recommend sealing of the exhaustpiping, cleaning, and servicing by alicensed heating contractor.
10.1 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 45 of 53
10.5 FireplaceComments: Inspected
The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Air filter is dirty and requiresreplacement.
10.4 (1)
Fireplace flue is dirty and requires cleaning. Consider having the chimney swept by a chimneycontractor.
10.5 (1) 10.5 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 46 of 53
11. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation
Styles & Materials
Exhaust Fans:Fan only
Items
11.0 FloorsComments: Inspected
11.1 WallsComments: Inspected
11.2 CeilingsComments: Inspected
11.3 DoorsComments: Inspected
11.4 WindowsComments: Inspected
11.5 SkylightsComments: Inspected
11.6 Electrical Receptacles and SwitchesComments: Inspected
11.7 LightingComments: Inspected
11.8 VentilationComments: Inspected
11.9 CabinetsComments: Inspected
11.10 ToiletComments: Inspected
11.11 BathtubComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 47 of 53
11.12 ShowerComments: Inspected
11.13 Medicine CabinetComments: Inspected
11.14 MirrorsComments: Inspected
11.15 SinkComments: Inspected
The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
Stopper for the bathtub ismissing.
11.11 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 48 of 53
12. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.
Styles & Materials
Cabinets:Solid WoodVeneer on MDF
Countertop Material:Laminate
Range:Electric
Range/Oven Brand:Samsung
Range Hood:Recirculating (removable filter)
Range Hood Brand:Samsung
Dishwasher:Present, Inspected
Dishwasher brand:Bosch
Dishwasher Anti-siphon method:No anti-siphon installed
Refrigerator:Inspected
Refridgerator Brand:Samsung
Items
12.0 FloorsComments: Inspected
12.1 WallsComments: Inspected
12.2 CeilingsComments: Inspected
12.3 DoorsComments: Inspected
12.4 WindowsComments: Inspected
12.5 SkylightsComments: Inspected
12.6 Interior TrimComments: Inspected
12.7 Receptacles and SwitchesComments: Inspected
12.8 LightingComments: Inspected
12.9 CabinetsComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 49 of 53
12.10 RangeComments: Inspected
12.11 Range HoodComments: Inspected
12.12 Garbage DisposalComments: Inspected
12.13 DishwasherComments: Inspected
12.14 CounterComments: Inspected
12.15 SinkComments: Inspected
The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
Downstairs bathroom sinkcabinet is damaged.
12.9 (1)
The dishwasher did not appear tohave an anti-siphon device installed inthe drain line. Anti-siphon devices areinstalled to prevent wastewater fromthe dishwasher from being siphonedback into the dishwasher andcontaminating its contents. TheInspector recommends an anti-siphondevice be installed by a qualifiedtechnician.
12.13 (1)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 50 of 53
13. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.
Styles & Materials
Dryer Power:Both available
Dryer Vent:Smooth-bore metal
Dryer 240-volt electrical receptacle:Modern 4-prong
Dryer Gas Supply:Natural gas
Items
13.0 FloorsComments: Inspected
13.1 WallsComments: Inspected
13.2 CeilingsComments: Inspected
13.3 DoorsComments: Inspected
13.4 WindowsComments: Inspected
13.5 Receptacles, Switches, ConnectionsComments: Inspected
13.6 LightingComments: Inspected
13.7 CabinetsComments: Inspected
13.8 Dryer VentingComments: Inspected
13.9 WasherComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 51 of 53
13.10 DryerComments: Inspected
The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
Washing machine water supplyvalve is leaking by. Recommendrepairs by a licensed plumber.
13.9 (1)
Electrical outlet requires a cover-plate. I would recommend adding a cap to the gas line until it is hookedup to a appliance.
13.10 (1) 13.10 (2)
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 52 of 53
INVOICE
NW WASHINGTON HOME INSPECTIONS LLC Bainbridge Island, WA
Inspected By: Carl Liberman
Inspection Date: 9/18/2017Report ID: 170918 B / ICN 10246AR003
Customer Info: Inspection Property:
Mrs. Alicia Pearson
Customer's Real Estate Professional:Chris EllisFaira.com
2977 Fircrest Dr SEPort Orchard Washington 98366
Inspection Fee:Service Price Amount Sub-TotalHome Inspection 425.00 1 425.00
Tax $0.00Total Price $425.00
Payment Method: CheckPayment Status: Invoice sent to AgentNote:
NW WASHINGTON HOME INSPECTIONS LLC Pearson
2977 Fircrest Dr SE Page 53 of 53