608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA 98444 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11432 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

1635 112th St S, Tacoma, WA 98444 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/11432 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Confidential Inspection Report

LOCATED AT:1635 112th St S

Tacoma, Washington 98444

PREPARED EXCLUSIVELY FOR:Faira.com

INSPECTED ON:Tuesday, June 5, 2018

Inspector, Isaac McPhee Strong Foundations Home Inspection

Page 3: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 2 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Executive Summary

This is a summary review of the inspectors' findings during this inspection. However, it does not contain every detailed observation. This is provided as an additional service to our client, and is presented in the form of a listing of the items which, in the opinion of your inspector, merit further attention, investigation, or improvement. Some of these conditions are of such a nature as to require repair or modification by a skilled craftsman, technician, or specialist. Others can be easily handled by a homeowner such as yourself.

Often, following the inspector's advice will result in improved performance and/or extended life of the component(s) in question. In listing these items, your inspector is not offering any opinion as to who, among the parties to this transaction, should take responsibility for addressing any of these concerns. As with most of the facets of your transaction, we recommend consultation with your Real Estate Professional for further advice with regards to the following items:

= Item that warrants repair or replacement now or in the near term, but does not pose an immediate risk or threat

= Upgrade recommended, but not required

= Potentially dangerous or hazardous condition that should be corrected as soon as possible (safety concern)

= Item not operating at the time of the inspection, or unable to be inspected for another reason

= Item that warrants continued monitoring or further evaluation by licensed professional. Though issues may not necessarily exist in the present or are not readily visible, monitoring or further evaluation is recommended.

Introductory Notes

NOTES

1: - Sections of this building may have been remodeled or added after original construction. We recommend consultation with the owner to determine if all necessary permits were obtained, inspections performed and final signatures obtained.

Exterior/Site/Ground

FOUNDATION

2: - There are small and/or moderate cracks visible. We observed no related conditions suggesting the need for immediate repairs. We recommend these cracks be monitored. If ongoing movement is observed, further review would then be recommended.

EXTERIOR PLUMBING

3: - Backflow prevention devices are now required on exterior hose bibs to prevent contamination of the domestic water supply. These devices are inexpensive and available at most hardware stores. Upgrading the hose bibs should be considered.

Page 4: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 3 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

HARDBOARD SIDING

4: - Sections of the masonry siding have minor, typical damage, particularly at the corners of the siding pieces, where cracks are often present. These cracks appear to have been repaired, but should be monitored for any additional cracking. Typically minor cracks can be caulked and painted.

SCREENS

5: - There is some minor damage to window screens here and there. Recommend repairing any damaged screens as needed.

WALKWAYS

6: - There are minor cracks of a cosmetic nature in the walkways. Action would only be required if any of the cracks develop into trip hazards in the future.

TRIM

7: - The trim shows routine wear but appears to be properly installed and in serviceable condition. We advise routine maintenance to ensure maximum service life.

FASCIA

8: - Portions of the fascia are weathered, with blistered and/or peeling paint. This will require surface preparation and refinishing in the course of routine property maintenance to restore surface appearance.

Roofing

Composition Shingle

SURFACE

9: - Some minor moss was growing on the roof surface. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely if the moss is left to grow unabated. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate based chemicals are used for this and must be applied periodically.

DOWNSPOUTS

10: - Runoff water from the roof discharges next to the house in one or more locations. We recommend the downspouts be routed sufficiently away from the structure to prevent puddling, pooling, and saturation of the soil around the building.

Garage

WIRING

11: - We found extension cord and/or improper wiring in use in this room. This type of wiring is easy to overload and can be easily damaged. Removal of all substandard wiring and replacement with proper circuitry is recommended.

GARAGE DOOR OPENER

12: - The garage door opener(s) is not equipped with photo sensors ("electric eyes") that stop and reverse the door when motion is detected. Recommend installing photo sensors on all garage doors to ensure safety.

Page 5: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 4 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

CEILING

13: - The ceiling surface is damaged, deteriorated, or stained in some areas. We recommend that it be repaired or replaced.

FLOOR

14: - There is cracking in the floor slab but there is no vertical displacement of any portion of the slab. No action is indicated.

GARAGE DOORS

15: - We observed gaps at the sides of the doors when closed, which could allow moisture or pest entry into the garage. We recommend adjustment or the installation of weatherstripping in order to fully seal to the exterior.

FIRE SEPARATION

16: - A high percentage of residential fires start in garages. This residence was constructed prior to requirements for a fire separation between the garage and the living space. Upgrading with fire-resistive construction should be considered.

Kitchen

VENTILATION

17: - Kitchen ventilation is provided by a ceiling mounted fan over the burners. The fan is excessively noisy and in need of repair or replacement.

Bedroom

Main Floor South

CEILING

18: - There is water staining, however no sign of active leakage was detected. If additional staining develops, the source of staining should be identified and necessary repairs performed. Prepare and refinish the ceiling to restore its appearance.

SMOKE DETECTOR

19: - There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

GENERAL COMMENT

20: - This area was added or improved after original construction. We recommend the owner or building department be consulted to determine if permits were secured and 'signed off' for all improvements completed.

Main Floor Northeast

WINDOWS

21: - One or more panes of glass are cracked/broken. We recommend all broken glass be replaced.

Page 6: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 5 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

SMOKE DETECTOR

22: - There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

Main Floor Northwest

SMOKE DETECTOR

23: - There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

Interior

WALLS & CEILINGS

24: - The sprayed-on acoustic ceilings may contain asbestos. Actual asbestos content can only be determined by laboratory testing. Further information on asbestos can be obtained from a licensed asbestos consultant or abatement contractor.

DOORS: OVERALL

25: - One or more of the deadbolts is the type that requires a key to operate from either side. This condition provides more security but can also be a hazard, especially in a fire. It is the occupant's choice as to which threat is taken more seriously.

WINDOWS: OVERALL

26: - The windows throughout the home are older and may not provide the energy efficiency of modern windows. Upgrading windows will result in greater energy efficiency and lower heating costs, but this is considered an optional upgrade.

DETECTORS: OVERALL

27: - Detectors were not found in all sleeping rooms. The latest standards require smoke detectors in all bedrooms at time of construction and when any significant work is done on the residence. Whether or not installation is required prior to sale of this building, upgrading should be considered.

Crawl Space

ACCESS

28: - The crawlspace hatch does not fully seal at the exterior. This condition may allow pests such as rodents to enter the crawlspace. Recommend sealing as completely as possible.

FOUNDATION

29: - There are small and/or moderate cracks visible. We observed no related conditions suggesting the need for immediate repairs. We recommend these cracks be monitored. If ongoing movement is observed, further review would then be recommended.

ANCHOR BOLTS

30: - The foundation is anchored using older technology. The original configuration has performed adequately to date. Upgrades might be considered as part of any future modernization and/or remodeling, but we do not consider this an urgent matter.

Page 7: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 6 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

PEST CONTROL

31: - Rodents or other animals have been active in the crawlspace. We recommend that the crawlspace be fully sealed and bait or traps be set and monitored. The advice and services of a licensed exterminator would be recommended if problems persist.

FLOOR INSULATION

32: - There are fiberglass batts that have fallen out of place or are not installed. We recommend this material be secured back in place.

Plumbing

WATER PRESSURE

33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary leakage and damage of system valves, seats and washers. We recommend that a pressure reduction valve be installed.

DRAIN LINES

34: - Based on the age of the home, we recommend a full camera review of the main line and waste piping system.

GENERAL COMMENT

35: - The home's supply piping either entirely or partially consists of galvanized steel piping. This piping is typically older, and has a limited lifespan. Though no specific leaks or damage was observed at the time of the inspection, we can make no representation regarding pipes hidden inside walls, underground, or behind insulation. Additionally, we observed some typical corrosion at some of the pipe joints, indicating older pipes.

Due to mineral deposit buildup and gradual reduction of flow, replacement of all remaining galvanized steel supply lines may eventually become necessary as a part of ongoing property maintenance and upgrading.

Water Heater

T/P RELEASE VALVE

36: - The temperature and pressure relief valve lacks a proper discharge pipe. We recommend the installation of approved piping to an approved location.

SEISMIC RESTRAINT

37: - The water heater tank lacks seismic restraint. As an upgrade, we recommend that the water heater be secured to help limit damage and provide a source of usable domestic water in the event of a major earthquake.

ELEVATION/LOCATION

38: - There is no metal pan under the water heater to catch and divert any dripping water to the exterior. This is required by some jurisdictions for water heaters in this location. We suggest installation of such a pan be considered.

Page 8: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 7 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENT

39: - This water heater is near the end of its expected service life. Although operating, the need for replacement should be expected within the next few years.

Electrical System

MAIN DISCONNECT

40: - There is no single main electrical service disconnect. If all the devices in the main service panel are disconnected, electrical power will be completely shut off.

SERVICE DROP

41: - The overhead service conductors are old and their insulation is frayed. We recommend the utility provider be notified of this condition so they can upgrade or replace the wires.

CB MAIN PANEL

42: - The electrical service to the home is provided by three older service panels in the garage. Our inspection of the wiring in this panels indicated numerous outdated and improper wiring methods, including double-tapped breakers and main lugs, improper and unlabeled wiring, unlabeled breakers, and others. The panels should be further evaluated and repaired by a licensed electrician in order to provide maximum safety to the home. Likely, the best solution would be to replace the three existing panels with a newer panel that is properly installed by a licensed electrician.

SERVICE CAPACITY

43: - The service capacity is only marginally adequate for present demand. It is our opinion, with changes in patterns of use, the existing electrical service will be found inadequate. We recommend upgrading the electrical service.

SERVICE GROUNDING

44: - The electrical system is not properly grounded. This is a potential safety hazard. We recommend the system be properly grounded in accordance with present standards.

RECEPTACLES: OVERALL

45: - There are numerous ungrounded three prong receptacles throughout the home. Though GFCI receptacles are present on some of the outlets and the outlets are all properly labeled, this condition still creates the illusion of ground fault protection that does not exist. We recommend upgrading by adding grounding to the outlets or restoring to their original two-prong configuration.

SWITCHES: OVERALL

46: - We tested a representative number of switches and found one or more to be without an obvious function. This is not necessarily a deficiency, but we suggest consultation with the owner as to their purpose.

GFI PROTECTION

47: - Some GFCI devices are installed in this home, though they are installed on a two-wire (ungrounded) system, which limits their effectiveness. We recommend adding these devices at all locations currently requiring this protection. This includes receptacles near sink basins, in bathrooms, garages, crawl spaces, and the exterior. In addition, we recommend upgrading all older devices (pre-2007) with newer devices for safety.

Page 9: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 8 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENT

48: - The electrical system was installed before grounding was required. Grounding of all equipment, circuits and convenience outlets would provide an increased margin of safety for the occupants.

49: - The electrical system was installed to meet minimum demands and uses older technology. Modern systems feature improvements in safety and convenience. We recommend upgrading and installing a new electrical system.

50: - We recommend upgrading the electrical system to comply with newer standards including GFCI, AFCI, surge protection, and other modern safety upgrades. Consult a licensed electrical contractor.

Conclusion

COMMENTS

51: - Note: Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs, and/or abatement specialists for this type of evaluation.

The home inspector considers the age of the home while inspecting. It is common to have areas that no longer comply with current code. This is not a new home and this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety issues, it does not inspect for code. It is common that homes of any age will have had repairs performed and some repairs may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are not functioning as intended. It does not grade the repair. It is common to see old plumbing or mixed materials. Sometimes water signs in crawlspaces or basements could be years old or from a problem that no longer exists. Or, it may still need further attention and repair. Determining this can be difficult on an older home. Sometimes in older homes there are signs of damage to wood from wood eating organisms. Having this is typical and fairely common. If the home inspection reveals signs of damage you should have a pest control company inspect further for activity and possibly hidden damage.

Page 10: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 9 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Tuesday, June 5, 2018Faira.com

1635 112th St STacoma, Washington 98444

Dear Faira.com,

We have enclosed the report for the property inspection we conducted for you on Tuesday, June 5, 2018 at:

1635 112th St STacoma, Washington 98444

Our report is designed to be clear, easy to understand, and helpful. Please take the time to review it carefully. If there is anything you would like us to explain, or if there is other information you would like, please feel free to call us. We would be happy to answer any questions you may have.

Throughout the report, you'll find special symbols at the front of certain comments. Below are the symbols and their meanings:

= Item that warrants repair or replacement now or in the near term, but does not pose an immediate risk or threat

= Upgrade recommended, but not required

= Potentially dangerous or hazardous condition that should be corrected as soon as possible (safety concern)

= Item not operating at the time of the inspection, or unable to be inspected for another reason

= Item that warrants continued monitoring or further evaluation by licensed professional. Though issues may not necessarily exist in the present or are not readily visible, monitoring or further evaluation is recommended.

We thank you for the opportunity to be of service to you.

Sincerely,

Inspector, Isaac McPheeStrong Foundations Home Inspection

Page 11: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 10 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Page 12: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Table of Contents

Executive Summary.......................................................................................................................................2

Introduction..................................................................................................................................................12

Introductory Notes.......................................................................................................................................13

Exterior/Site/Ground....................................................................................................................................13

Roofing........................................................................................................................................................21

Garage.........................................................................................................................................................25

Kitchen.........................................................................................................................................................30

Bathroom.....................................................................................................................................................33

Bedroom......................................................................................................................................................37

Living Room.................................................................................................................................................42

Interior.........................................................................................................................................................44

Attic..............................................................................................................................................................46

Crawl Space................................................................................................................................................49

Plumbing......................................................................................................................................................51

Water Heater...............................................................................................................................................55

Electrical System.........................................................................................................................................57

Insulation/Energy.........................................................................................................................................61

Locations of Emergency Controls................................................................................................................63

Environmental Concerns.............................................................................................................................64

Conclusion...................................................................................................................................................64

tmpAAF8......................................................................................................................................................66

Page 13: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 12 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Introduction

We have inspected the major structural components and mechanical systems for signs of significant non- performance, excessive or unusual wear and general state of repair. The following report is an overview of the conditions observed.

In the report, there may be specific references to areas and items that were inaccessible. We can make no representations regarding conditions that may be present but were concealed or inaccessible for review. With access and an opportunity for inspection, reportable conditions may be discovered. Inspection of the inaccessible areas will be performed upon arrangement and at additional cost after access is provided.

We do not review plans, permits, recall lists, and/or government or local municipality documents. Information regarding recalled appliances, fixtures and any other items in this property can be found on the Consumer Product Safety website. These items may be present but are not reviewed.

Our recommendations are not intended as criticisms of the building, but as professional opinions regarding conditions present. As a courtesy, the inspector may list items that they feel have priority in the Executive Summary portion of the report. Although the items listed in this section may be of higher priority in the opinion of the inspector, it is ultimately the client's responsibility to review the entire report. If the client has questions regarding any of the items listed, please contact the inspector for further consultation.

Lower priority conditions contained in the body of the report that are neglected may become higher priority conditions. Do not equate low cost with low priority. Cost should not be the primary motivation for performing repairs. All repair and upgrade recommendations are important and need attention.

This report is a "snapshot" of the property on the date of the inspection. The structure and all related components will continue to deteriorate/wear out with time and may not be in the same condition at the close of escrow.

Anywhere in the report that the inspector recommends further review, it is strongly recommended that this be done PRIOR TO THE CLOSE OF ESCROW. This report is not intended for use by anyone other than the client named herein. No other persons should rely upon the information in this report. Client agrees to indemnify, defend and hold inspector harmless from any third party claims arising out of client's unauthorized distribution of the inspection report.

By accepting this inspection report, you acknowledge that you have reviewed and are in agreement with all of the terms contained in the standard contract provided by the inspector who prepared this report.

Page 14: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 13 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Introductory Notes

ORIENTATIONFor purposes of identification and reporting, the front of this building faces south.

NOTESThe house was estimated to be approximately 64 years old.

The weather was sunny at the time of our inspection.

Over the course of this inspection the temperature was estimated to be between 50 and 60 degrees.

We make no representations as to the extent or presence of code violations, nor do we warrant the legal use of this building. This information would have to be obtained from the local building and/or zoning department.

There may be information pertinent to this property which is a matter of public record. A search of public records is not within the scope of this inspection. We recommend the client or their representative review all appropriate public records.

Sections of this building may have been remodeled or added after original construction. We recommend consultation with the owner to determine if all necessary permits were obtained, inspections performed and final signatures obtained.

The scope of this inspection is limited to reasonably accessible areas. We make no attempt to move furnishings, stored personal property, and/or vegetation. Although no problems are anticipated, removal of these items may reveal reportable items.

Your inspector may choose to include photos in your inspection report. There are times when only a picture can fully explain the condition or if the client is unable to attend the inspection. Photo inclusion is at the discretion of the inspector and in no way is meant to emphasize or highlight the only conditions that were seen. We always recommend full review of the entire inspection report.

Exterior/Site/Ground

BASIC INFORMATIONGeneral lot topography: Flat lot

Page 15: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 14 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Driveway: Asphalt

Walkways: Concrete

Primary exterior wall covering: Masonry Board/Shingle

Page 16: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 15 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Secondary exterior wall covering: Wood lap siding

Primary exterior window material: Metal frame

Page 17: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 16 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

FOUNDATION

There are small and/or moderate cracks visible. We observed no related conditions suggesting the need for immediate repairs. We recommend these cracks be monitored. If ongoing movement is observed, further review would then be recommended.

Page 18: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 17 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

EXTERIOR PLUMBINGThe plumbing on the exterior of the building and in the yard appears to be properly installed and in serviceable condition. We make no attempt to locate and test every hose bib. Testing of irrigation systems is beyond the scope of our inspection.

Backflow prevention devices are now required on exterior hose bibs to prevent contamination of the domestic water supply. These devices are inexpensive and available at most hardware stores. Upgrading the hose bibs should be considered.

GAS METER COMMENTSThere is no gas meter. This property is not served by a gas utility.

OUTDOOR RECEPTACLESThe receptacles were found to be properly installed and in serviceable condition.

OUTDOOR LIGHTSThe outdoor lights were tested and appeared functional at the time of the inspection.

Page 19: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 18 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

HARDBOARD SIDING

Sections of the masonry siding have minor, typical damage, particularly at the corners of the siding pieces, where cracks are often present. These cracks appear to have been repaired, but should be monitored for any additional cracking. Typically minor cracks can be caulked and painted.

DOORSThe exterior doors appear to be properly installed and in serviceable condition.

Most exterior door locks can be rekeyed after transfer of ownership to ensure personal safety and security.

WINDOWSThe windows appear to be properly installed and in serviceable condition.

SCREENS

There is some minor damage to window screens here and there. Recommend repairing any damaged screens as needed.

GRADINGThe grading of the lot appears to properly and adequately drain excess surface water and roof runoff away from the structure.

Page 20: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 19 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

DRAINAGEThe surface water drainage system is below grade and cannot be viewed. Designs and materials for these systems vary widely, making it impossible to evaluate the integrity of the system with any certainty.

We could not determine the discharge location of the drainage system. We suggest inquiries and/or observation during a heavy rain to discover the discharge location and effectiveness of the system.

The drainage system should be checked for debris and cleaned regularly to ensure proper operation during heavy weather.

PUBLIC WORKSThe owner may have rights and responsibilities concerning the public improvements associated with this property. We suggest inquiries of the local public works department, particularly regarding liabilities for future maintenance costs.

DRIVEWAYThe driveway appears to be properly installed and is generally in good condition.

WALKWAYS

There are minor cracks of a cosmetic nature in the walkways. Action would only be required if any of the cracks develop into trip hazards in the future.

Page 21: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 20 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

TRIM

The trim shows routine wear but appears to be properly installed and in serviceable condition. We advise routine maintenance to ensure maximum service life.

FASCIA

Portions of the fascia are weathered, with blistered and/or peeling paint. This will require surface preparation and refinishing in the course of routine property maintenance to restore surface appearance.

Page 22: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 21 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

EAVES/SOFFITSThe eaves and overhangs appear to be properly installed and in good condition.

PAINT/STAINThe exterior finishes are in good condition and have an attractive appearance.

GENERAL COMMENTThe exterior features of the building generally appear to be properly installed and in serviceable condition. Exceptions are discussed above and elsewhere in this report. Regular maintenance will prolong the service life of the 'weather shell'.

As preventive maintenance, caulking and sealing the gaps in the exterior of the building around the doors, windows, plumbing and electrical entry points will help prevent heat loss, cold air infiltration and moisture entry.

If caulking is needed for maintenance of any flashing or exterior trim, we suggest a high quality urethane sealant such as 'Sikaflex'. Latex, butyl, oil based, silicone or 'architectural grade' sealants should be avoided.

Roofing

A roof system consists of the surface materials, connections, penetrations and drainage (gutters and downspouts). We visually review these components for damage and deterioration and do not perform any destructive testing. If we find conditions suggesting damage, improper application, or limited remaining service life, these will be noted. We may also offer opinions concerning repair and replacement. Opinions stated herein concerning the roof are based on a limited visual inspection. These do not constitute a warranty that the roof is, or will remain, free of leaks.

Page 23: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 22 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Composition Shingle

BASIC INFORMATIONLocation: Covers whole building

Roof slope: MediumMaterial: Asphalt composition shingleLayers: Unknown, would require destructive testingAge: Approximately 7+ years oldConnections and penetrations: Sealed with metal flashingRoof drainage system: Gutters and downspouts

INSPECTION METHODOur inspection of this roof was conducted from the roof surface. The inspector walked upon the surface and visually examined the accessible roofing components.

SURFACEThe shingle surface appears to have been properly installed and is in good condition.

Page 24: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 23 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Some minor moss was growing on the roof surface. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely if the moss is left to grow unabated. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate based chemicals are used for this and must be applied periodically.

FLASHINGS: OVERALLMetal flashing has been used to seal the connections and penetrations.

The accessible connection and penetration flashings appear to be properly installed and in serviceable condition. All of the connections and penetrations should be periodically examined for signs of leakage and repairs performed if necessary.

Page 25: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 24 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

PLUMBING VENTSPlumbing vents at the roof appear properly installed and in satisfactory condition.

GUTTERSRoof runoff water is channeled to the downspouts by a metal gutter system attached to the fascia boards or to the ends of the rafters along the edge of the roof.

Page 26: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 25 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

DOWNSPOUTS

Runoff water from the roof discharges next to the house in one or more locations. We recommend the downspouts be routed sufficiently away from the structure to prevent puddling, pooling, and saturation of the soil around the building.

GENERAL COMMENTThe roof covering appears to have been installed in a professional and workmanlike fashion. We observed no signs of unusual or excessive wear of the roofing components that would suggest immediate attention is required.

Garage

WALL FRAMINGIn the areas where the wall framing is visible, all components appear to be properly installed and generally in good condition, though older and likely not up to modern framing standards.

Page 27: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 26 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

WIRING

We found extension cord and/or improper wiring in use in this room. This type of wiring is easy to overload and can be easily damaged. Removal of all substandard wiring and replacement with proper circuitry is recommended.

GARAGE DOOR OPENER

The garage door opener(s) is not equipped with photo sensors ("electric eyes") that stop and reverse the door when motion is detected. Recommend installing photo sensors on all garage doors to ensure safety.

CEILING

The ceiling surface is damaged, deteriorated, or stained in some areas. We recommend that it be repaired or replaced.

FLOORThe floor is a concrete slab.

Page 28: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 27 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

There is cracking in the floor slab but there is no vertical displacement of any portion of the slab. No action is indicated.

GARAGE DOORSThe garage is equipped with two roll up doors.

Operation of one or more door(s) is controlled by a motorized mechanism, more commonly referred to as an automatic opener.

We observed gaps at the sides of the doors when closed, which could allow moisture or pest entry into the garage. We recommend adjustment or the installation of weatherstripping in order to fully seal to the exterior.

Page 29: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 28 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

DRYER VENTThe dryer vent appears properly installed and in serviceable condition.

FIRE SEPARATION

A high percentage of residential fires start in garages. This residence was constructed prior to requirements for a fire separation between the garage and the living space. Upgrading with fire-resistive construction should be considered.

Page 30: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 29 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

WASHER/DRYERThe hookups for the washer and dryer are properly installed and in serviceable condition. The appliances themselves were not tested.

GENERAL COMMENTThis area is in need of repair as noted above or in other sections of this report.

Page 31: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 30 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

This area was added or improved after original construction. We recommend the owner or building department be consulted to determine if permits were secured and 'signed off' for all improvements completed.

Kitchen

The kitchen is visually inspected for proper function of components, active leakage, excessive or unusual wear, and general state of repair. We inspect built-in appliances to the extent possible using normal operating controls. Freestanding stoves are operated, but refrigerators, small appliances, portable dishwashers, and microwave ovens are not tested.

BASIC INFORMATIONEnergy: Electric appliances onlyVentilation: Exhaust ducted to the exteriorRefrigerators, wine coolers, and other cooling appliances are beyond the scope of this inspection

DRAIN TRAPSThe drain trap and associated piping are PVC plastic.

Page 32: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 31 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

SINKThe sink is porcelain.

The sink appears to be properly installed. When operated, it was observed to be fully functional and in serviceable condition.

LIGHTSThe overhead kitchen lights were tested and found to be operational at the time of the inspection.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

COUNTERTOPSThe countertop is a plastic laminate.

The countertop shows typical wear and tear, normal for this heavily used component. We considered the flaws cosmetic in nature with no action indicated.

Page 33: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 32 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

VENTILATION

Kitchen ventilation is provided by a ceiling mounted fan over the burners. The fan is excessively noisy and in need of repair or replacement.

STOVEThe stove was turned on with the normal operating controls and found to be in satisfactory working condition.

OVENThe oven was turned on with the normal operating controls and found to be in satisfactory working condition.

DISPOSALThis kitchen is not equipped with a garbage disposal.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Page 34: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 33 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Bathroom

Bathrooms are visually inspected for proper function of components, active leakage, excessive or unusual wear and general state of repair. Fixtures are tested using normal operating features and controls. Due to finished surfaces such as drywall/plaster, tile, and flooring, much of the bathroom is considered inaccessible. We do not test or confirm proper application of secondary equipment including but not limited to steam units, spa tubs, heated towel bars, etc.

BASIC INFORMATIONToilet: Ceramic unit with a porcelain finish

Wash basin: Ceramic unit with a porcelain finish

Page 35: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 34 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Bathtub: Cast iron with porcelain finish

Shower walls: Mortar set ceramic tile

Page 36: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 35 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

DRAIN TRAPThe drain trap and associated piping are PVC plastic.

TOILETThe toilet was flushed and appeared to be functioning properly.

WATER BASINThe wash basin appears to be properly installed. When operated, it was observed to be fully functional and in serviceable condition.

BATHTUBThe bathtub appears to be properly installed and in serviceable condition.

SHOWERThe shower was operated for the inspection and appeared to be in serviceable condition.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

Page 37: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 36 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

SHOWER WALLSThe shower walls appear to be properly installed and in serviceable condition.

BATHROOM FLOORThe floor appears to be properly installed and is in serviceable condition.

VENTILATIONVentilation in this bathroom is provided by a vent fan in the ceiling. This fan was operated and was found to be working satisfactorily.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Page 38: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 37 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Bedroom

Main Floor South

LIGHTS / FANThe bedroom lights and/or fan were tested using normal controls and appeared to be functioning properly.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

CEILING

There is water staining, however no sign of active leakage was detected. If additional staining develops, the source of staining should be identified and necessary repairs performed. Prepare and refinish the ceiling to restore its appearance.

SMOKE DETECTOR

There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

Page 39: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 38 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

This area was added or improved after original construction. We recommend the owner or building department be consulted to determine if permits were secured and 'signed off' for all improvements completed.

Main Floor Northeast

LIGHTS / FANThe bedroom lights and/or fan were tested using normal controls and appeared to be functioning properly.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

Page 40: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 39 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

WINDOWS

One or more panes of glass are cracked/broken. We recommend all broken glass be replaced.

SMOKE DETECTOR

There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

Page 41: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 40 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Main Floor Northwest

LIGHTS / FANThe bedroom lights and/or fan were tested using normal controls and appeared to be functioning properly.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

Page 42: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 41 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

FLOORThe floors are covered with wall-to-wall carpet. No attempt was made to determine the type or condition of the material under the carpet.

SMOKE DETECTOR

There is no smoke detector in this area, as required by modern safety standards. Though the home was built before modern safety standards, we recommend one be installed.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Page 43: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 42 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Living Room

LIGHTSThe lights and/or ceiling fan in this room were tested using standard operating controls and appeared to operate properly.

RESISTANCE HEATERThe electrical resistance heater appears to be properly installed and in serviceable condition and responded to the user controls.

Page 44: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 43 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

FLOORThe laminate flooring was in functional condition, with only wear and tear typical of normal use.

GENERAL COMMENTThe finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time of our inspection. However, this area is in need of routine maintenance as noted above or in other sections of this report.

Page 45: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 44 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Inspection of this area was limited to the surface coverings. The construction materials and manner of installation were concealed from view and inaccessible.

Interior

Our review of the interior includes inspection of walls, ceilings, floors, doors, windows, steps, stairways, balconies and railings. These features are visually examined for proper function, excessive wear and general state of repair. Some of these components may not be visible/accessible because of furnishings and/or storage. In such cases these items are not inspected.

BASIC INFORMATIONNumber of bedrooms: ThreeNumber of bathrooms: OneWindow material: MetalWindow type: Horizontal and Vertical sliding windowsWindow glazing: Double paneFinished ceiling material: Sprayed-on acoustic and acoustic tilesFinished floor material: Carpet and wood or laminateFinished wall material: Drywall

SURFACES: OVERALLThe interior wall, floor, and ceiling surfaces were properly installed and generally in serviceable condition, taking into consideration normal wear and tear.

WALLS & CEILINGSThe interior wall and ceiling blemishes are cosmetic and can be repaired in the course of routine maintenance.

The sprayed-on acoustic ceilings may contain asbestos. Actual asbestos content can only be determined by laboratory testing. Further information on asbestos can be obtained from a licensed asbestos consultant or abatement contractor.

FLOORS: OVERALLThe floors have a good appearance and are in serviceable condition, with exceptions noted below.

Page 46: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 45 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

DOORS: OVERALLThe interior doors appear to be properly installed and in good condition, with exceptions noted below.

One or more of the deadbolts is the type that requires a key to operate from either side. This condition provides more security but can also be a hazard, especially in a fire. It is the occupant's choice as to which threat is taken more seriously.

WINDOWS: OVERALLWe operate a representative sample of the windows, but do not necessarily open, close, and latch every window. Our inspection standards require testing a minimum of one window in every room.

The windows throughout the home are older and may not provide the energy efficiency of modern windows. Upgrading windows will result in greater energy efficiency and lower heating costs, but this is considered an optional upgrade.

DETECTORS: OVERALLThe smoke detectors were inspected for location only. For future reference, testing with only the built-in test button verifies proper battery and horn function, but does not test the smoke sensor. We advise testing with real or simulated smoke.

Detectors were not found in all sleeping rooms. The latest standards require smoke detectors in all bedrooms at time of construction and when any significant work is done on the residence. Whether or not installation is required prior to sale of this building, upgrading should be considered.

Page 47: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 46 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Carbon monoxide detectors were observed during the inspection on each floor of living space and tested using the "test" button for operation.

HEAT SOURCEWe observed a permanent heat source in each room throughout the building.

GENERAL COMMENTThe interior surfaces, hardware, fixtures, doors and windows appear to be properly installed and generally in serviceable condition, with exceptions noted above.

We make no attempt to list all cosmetic flaws and suggest that most of these deficiencies will be addressed by normal maintenance and upgrading.

Attic

The attic contains the roof framing and serves as a raceway for components of the mechanical systems. There are often heating ducts, electrical wiring and appliance vents in the attic. We visually examine the attic components for proper function, excessive or unusual wear, general state of repair, leakage, venting and misguided improvements. Where walking in an unfinished attic can result in damage to the ceiling, inspection is from the access opening only.

Page 48: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 47 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

ACCESS/ENTRYThe attic access is located in the garage.

SHEATHINGThe roof sheathing is the material directly supporting the roof covering.

The roof sheathing is boards nailed solidly across the rafters with no gaps between them.

The roof sheathing appears to be properly installed and in good condition.

ROOF TRUSSESRoof trusses support the roof sheathing and roof covering, transferring loads to the bearing walls. The bottom of a truss supports the finished ceiling. Trusses are usually engineered components assembled in a factory and delivered to the site.

Page 49: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 48 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

The trusses are generally in good condition, where seen, and have performed adequately since their installation.

VENT LINESThe vent piping for the waste system appears to be properly installed and in good condition.

INTERIOR LIGHTSAttic lights were tested and were operational at the time of the inspection.

VENTILATIONOur feeling regarding attic ventilation is that 'you can never have too much'. Attic ventilation can be provided by eave, gable, and ridge vents as well as by automatic and wind driven fans. We encourage use of any or all of the above.

The attic appeared to be adequately vented (though different temperature or weather conditions may reveal inadequacies in the attic venting). Good ventilation helps reduce attic moisture levels and prevents condensation on the underside of the roof. In addition, it reduces heat build-up in the attic, making the house more comfortable.

Page 50: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 49 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Crawl Space

The crawl space is where most of the building's structural elements and portions of its mechanical systems are located. These include foundation, structural framing, electrical, plumbing and heating. Each accessible and visible component and system is examined for proper function, excessive or unusual wear and general state of repair. It is not unusual to find occasional moisture and dampness in crawl spaces. Significant and/or frequent water accumulation can adversely affect the building foundation and support system and would indicate the need for further evaluation by a specialist. Although observed in the crawl space, some items will be reported under the individual systems to which they belong.

BASIC INFORMATIONFoundation type: Raised perimeter with isolated piersFoundation material: Poured concreteMudsill: Minimally boltedWall system: Wood stud wallsFloor system: Wood joists support by beams

ACCESSThe crawl space is accessible from exterior hatches.

The crawlspace hatch does not fully seal at the exterior. This condition may allow pests such as rodents to enter the crawlspace. Recommend sealing as completely as possible.

FOUNDATION

There are small and/or moderate cracks visible. We observed no related conditions suggesting the need for immediate repairs. We recommend these cracks be monitored. If ongoing movement is observed, further review would then be recommended.

MUDSILLThe mudsill is the first wood member of the framing, resting directly on the foundation. The accessible sections of mudsill are in good condition.

FLOOR JOISTSIn the areas where the floor framing is visible, all components appear to be properly installed and in good condition.

Page 51: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 50 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

POSTSThe floor system is supported by wooden posts set over concrete pier blocks.

The support posts have performed adequately over time and would be expected to continue to do so.

ANCHOR BOLTSBecause of the design and/or configuration of the construction, we cannot verify the presence or condition of anchor bolts.

The foundation is anchored using older technology. The original configuration has performed adequately to date. Upgrades might be considered as part of any future modernization and/or remodeling, but we do not consider this an urgent matter.

MOISTUREThe soil was dry at the time of our inspection, and there were no adverse conditions or damage observed related to excessive moisture.

Page 52: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 51 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

VAPOR BARRIERThe soil has been covered with plastic sheeting, probably installed in an attempt to reduce moisture levels in the crawl space atmosphere. This is considered a beneficial feature and is required in some jurisdictions.

VENTILATIONVentilation in the crawl space is adequate. Good ventilation in the crawl space is important to keep moisture levels down. Keeping the vents clear of debris and vegetation should be part of regular maintenance.

PEST CONTROL

Rodents or other animals have been active in the crawlspace. We recommend that the crawlspace be fully sealed and bait or traps be set and monitored. The advice and services of a licensed exterminator would be recommended if problems persist.

FLOOR INSULATION

There are fiberglass batts that have fallen out of place or are not installed. We recommend this material be secured back in place.

GENERAL COMMENTAll of the structural elements appear to be performing as would be expected for a dwelling of this age and type. However, we direct your attention to items noted above. Additional crawl space comments can be found under the heading crawl space.

Plumbing

A plumbing system consists of the domestic water supply lines, drain, waste and vent lines and gas lines. Inspection of the plumbing system is limited to visible faucets, fixtures, valves, drains, traps, exposed pipes and fittings. These items are examined for proper function, excessive or unusual wear, leakage, and general state of repair. The hidden nature of piping prevents inspection of every pipe and joint. A sewer lateral test, necessary to determine the condition of the underground sewer lines, is beyond the scope of this inspection If desired, a qualified individual could be retained for such a test. Our review of the plumbing system does not include landscape watering, fire suppression systems, private water supply/waste disposal systems, or recalled plumbing supplies. Review of these systems requires a

Page 53: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 52 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

qualified and licensed specialist.

BASIC INFORMATIONDomestic water source: Public supply

Main water line: Galvanized steel

Page 54: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 53 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Supply piping: Galvanized steel and PEX plastic

Waste disposal: MunicipalWaste piping: Cast iron and plastic

Water pressure: Excessive (greater than 80 PSI)

Page 55: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 54 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

WATER SHUTOFF LOCATIONThe domestic water supply main shut-off valve is on the front wall in the underbuilding crawl space.

WATER SHUTOFF COMMENTSThe main shut-off valve was located but testing the operation of this valve is not within the scope of our inspection. Operation of the valve from time to time will keep it functional and maximize its useful life.

MAIN SUPPLYThere was no evidence of surface corrosion or leakage at the exposed and accessible main supply.

INTERIOR SUPPLYThe exposed and accessible supply piping generally appears to be properly installed and in good condition.

WATER PRESSURE

The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary leakage and damage of system valves, seats and washers. We recommend that a pressure reduction valve be installed.

DRAIN LINESThe visible drain piping appears to be generally properly installed and in serviceable condition. We recommend a full camera review of the entire waste system.

Based on the age of the home, we recommend a full camera review of the main line and waste piping system.

SEWER CLEANOUTThe sewer cleanout is located on the left side of the structure.

VENT LINESThe vent piping for the waste system appears to be properly installed and in good condition.

GAS METER COMMENTThere is no gas meter. This property is not served by a gas utility.

Page 56: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 55 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENTThe plumbing system appears to be in good condition, with the exceptions noted above.

A representative number of fixtures were operated and we observed reasonable flow when other fixtures were operated simultaneously.

A representative number of drains were tested and each emptied in a reasonable amount of time and did not overflow when other fixtures were drained simultaneously.

The home's supply piping either entirely or partially consists of galvanized steel piping. This piping is typically older, and has a limited lifespan. Though no specific leaks or damage was observed at the time of the inspection, we can make no representation regarding pipes hidden inside walls, underground, or behind insulation. Additionally, we observed some typical corrosion at some of the pipe joints, indicating older pipes.

Due to mineral deposit buildup and gradual reduction of flow, replacement of all remaining galvanized steel supply lines may eventually become necessary as a part of ongoing property maintenance and upgrading.

Water Heater

Our review of water heaters includes the tank, water and gas connections, electrical connections, venting and safety valves. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. We do not fully review tankless/on-demand systems and suggest you consult a specialist. The hidden nature of piping and venting prevents inspection of every pipe, joint, vent and connection.

BASIC INFORMATIONLocation: Kitchen cabinet (behind stove)

Energy source: ElectricityCapacity: 30 gallonsAge: Estimated to be 13+ years oldUnit type: Free standing tankWater heater temperature settings should be maintained in the mid-range to avoid injury from scalding

Page 57: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 56 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Insulation: Yes, installed behind outer jacket

T/P RELEASE VALVE

The temperature and pressure relief valve lacks a proper discharge pipe. We recommend the installation of approved piping to an approved location.

WATER CONNECTORSThe cold water inlet and hot water outlet connections appear properly installed and in serviceable condition.

SEISMIC RESTRAINT

The water heater tank lacks seismic restraint. As an upgrade, we recommend that the water heater be secured to help limit damage and provide a source of usable domestic water in the event of a major earthquake.

ELEVATION/LOCATION

There is no metal pan under the water heater to catch and divert any dripping water to the exterior. This is required by some jurisdictions for water heaters in this location. We suggest installation of such a pan be considered.

INSULATIONThere is no insulation blanket installed. Newer water heaters have built-in insulation to meet rigorous conservation standards. Installation of a blanket can be done but offers very little improvement on the existing efficiency of the unit.

Page 58: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 57 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

GENERAL COMMENT

This water heater is near the end of its expected service life. Although operating, the need for replacement should be expected within the next few years.

Electrical System

An electrical system consists of the service, distribution, wiring and convenience outlets (switches, lights, and receptacles). Our examination of the electrical system includes the exposed and accessible conductors, branch circuitry, panels, overcurrent protection devices, and a random sampling of convenience outlets. We look for adverse conditions such as improper installation, exposed wiring, running splices, reversed polarity and circuit protection devices. We do not evaluate fusing and/or calculate circuit loads. The hidden nature of the electrical wiring prevents inspection of every length of wire.

BASIC INFORMATIONService entry into building: Overhead service dropVoltage supplied by utility: 120/240 voltsCapacity (available amperage): 100 amperesSystem grounding source: Appears ungroundedBranch circuit protection: Circuit breakersWiring method: A combination of newer and older style non-metallic sheathed cable or 'romex'

Page 59: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 58 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

ELECTRIC METERThe electric meter is outside on the left side of the building.

MAIN SERVICEThe main electrical service panel is in the garage.

MAIN DISCONNECT

There is no single main electrical service disconnect. If all the devices in the main service panel are disconnected, electrical power will be completely shut off.

Page 60: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 59 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

SERVICE DROP

The overhead service conductors are old and their insulation is frayed. We recommend the utility provider be notified of this condition so they can upgrade or replace the wires.

CB MAIN PANELFor attention to the condition(s) noted above, and/or cost estimates, if necessary, we recommend the advice and services of a licensed electrical contractor.

The electrical service to the home is provided by three older service panels in the garage. Our inspection of the wiring in this panels indicated numerous outdated and improper wiring methods, including double-tapped breakers and main lugs, improper and unlabeled wiring, unlabeled breakers, and others. The panels should be further evaluated and repaired by a licensed electrician in order to provide maximum safety to the home. Likely, the best solution would be to replace the three existing panels with a newer panel that is properly installed by a licensed electrician.

Page 61: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 60 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

SERVICE CAPACITY

The service capacity is only marginally adequate for present demand. It is our opinion, with changes in patterns of use, the existing electrical service will be found inadequate. We recommend upgrading the electrical service.

SERVICE GROUNDING

The electrical system is not properly grounded. This is a potential safety hazard. We recommend the system be properly grounded in accordance with present standards.

RECEPTACLES: OVERALL

There are numerous ungrounded three prong receptacles throughout the home. Though GFCI receptacles are present on some of the outlets and the outlets are all properly labeled, this condition still creates the illusion of ground fault protection that does not exist. We recommend upgrading by adding grounding to the outlets or restoring to their original two-prong configuration.

SWITCHES: OVERALL

We tested a representative number of switches and found one or more to be without an obvious function. This is not necessarily a deficiency, but we suggest consultation with the owner as to their purpose.

LIGHTS: OVERALLThe light fixtures in this building are generally in serviceable condition.

GFI PROTECTIONGFCI (ground fault circuit interrupter) protection is a modern safety feature designed to prevent shock hazards. GFCI breakers and receptacles function to de-energize a circuit or a portion of a circuit when a hazardous condition exists.

GFCI protection is inexpensive and can provide a substantial increased margin of safety.

Page 62: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 61 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Some GFCI devices are installed in this home, though they are installed on a two-wire (ungrounded) system, which limits their effectiveness. We recommend adding these devices at all locations currently requiring this protection. This includes receptacles near sink basins, in bathrooms, garages, crawl spaces, and the exterior. In addition, we recommend upgrading all older devices (pre-2007) with newer devices for safety.

GENERAL COMMENT

The electrical system was installed before grounding was required. Grounding of all equipment, circuits and convenience outlets would provide an increased margin of safety for the occupants.

If grounding of all equipment and circuits is not provided, we recommend at least grounding the receptacles in the kitchen, bathroom(s), garage and outside.

The electrical system was installed to meet minimum demands and uses older technology. Modern systems feature improvements in safety and convenience. We recommend upgrading and installing a new electrical system.

We recommend upgrading the electrical system to comply with newer standards including GFCI, AFCI, surge protection, and other modern safety upgrades. Consult a licensed electrical contractor.

Insulation/Energy

Insulation, weatherstripping, dampers, double-glazed glass and set-back thermostats are features that help reduce heat loss and/or gain and increase system and appliance efficiency. Our visual inspection includes review to determine if these features are present in representative locations and we may offer suggestions for upgrading. Our review of insulation is based upon uniformly insulated or are insulated to current standards. It is our opinion that all homes could benefit from energy conservation upgrades, and we suggest that you consult professionals.

ATTIC INSULATIONThe attic has blown-in or loose-fill fiberglass insulation and fiberglass batts

Page 63: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 62 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

WALL INSULATIONWe were unable to access the wall cavities and/or determine the presence or condition of insulation.

FLOOR INSULATIONThe floor insulation appears to be properly installed and in good condition.

GENERAL COMMENTThe structure appears to be generally adequately insulated (where the insulation could be seen), given the age of the home. Though some minor repairs or upgrades could be made, the energy efficiency of the home is generally considered adequate.

Page 64: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 63 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Locations of Emergency Controls

In an emergency, you may need to know where to shut off the gas, the water and/or the electrical system. We have listed below these controls and their location for your convenience. We urge that you familiarize yourself with their location and operation.

WATER SHUTOFF LOCATIONPLUMBINGThe domestic water supply main shut-off valve is on the front wall in the underbuilding crawl space.

SEWER CLEANOUTPLUMBINGThe sewer cleanout is located on the left side of the structure.

ELECTRIC METERELECTRICAL SYSTEMThe electric meter is outside on the left side of the building.

Page 65: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 64 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

MAIN SERVICEELECTRICAL SYSTEMThe main electrical service panel is in the garage.

MAIN DISCONNECTELECTRICAL SYSTEM

There is no single main electrical service disconnect. If all the devices in the main service panel are disconnected, electrical power will be completely shut off.

Environmental Concerns

Environmental issues include but are not limited to radon, fungi/mold, asbestos, lead paint, lead contamination, toxic waste, formaldehyde, electromagnetic radiation, buried fuel oil tanks, ground water contamination and soil contamination. We are not trained or licensed to recognize or discuss any of these materials. We may make reference to one of more of these materials in this report when we recognize one of the common forms of these substances. If further study or analysis seems prudent, the advice and services of the appropriate specialists are advised.

Conclusion

COMMENTSThis structure appears to be of standard quality, in need of miscellaneous repair and upgrading. There is also maintenance in need of attention. Examples of these conditions have been described in this report.

If performed routinely, this type of construction requires average maintenance to keep it in serviceable condition.

Many homes built prior to 1996 lack modern safety and energy efficient items.

Page 66: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

Page 65 of 86Copyright© 2010-2018, SPECTACULAR, Strong Foundations Home Inspection, Isaac McPhee 18-06001

Note: Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs, and/or abatement specialists for this type of evaluation.

The home inspector considers the age of the home while inspecting. It is common to have areas that no longer comply with current code. This is not a new home and this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety issues, it does not inspect for code. It is common that homes of any age will have had repairs performed and some repairs may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are not functioning as intended. It does not grade the repair. It is common to see old plumbing or mixed materials. Sometimes water signs in crawlspaces or basements could be years old or from a problem that no longer exists. Or, it may still need further attention and repair. Determining this can be difficult on an older home. Sometimes in older homes there are signs of damage to wood from wood eating organisms. Having this is typical and fairely common. If the home inspection reveals signs of damage you should have a pest control company inspect further for activity and possibly hidden damage.

Page 67: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

ADDENDA TO INSPECTION REPORT 1. The inspection to be performed for Client consists of non-intrusive visual observations to survey the readily accessible, easily visible material components, systems and equipment of the building. The inspection is designed to identify material physical deficiencies in the building’s components, systems and equipment, as they exist at the time of the inspection. The work product resulting from completing an inspection in accordance with this contract is an inspection report. The inspection report incorporates the information obtained during the inspection. The inspection report is for the sole use and benefit of the Client. Client agrees to read the entire inspection report when it is received and shall promptly call the Inspector with any questions or concerns Client may have regarding the inspection report or the inspection. The inspection report shall be considered the final and exclusive findings of the Inspector regarding the inspection of the building. Client shall not rely on any oral statement made by the Inspector prior to issuance of the inspection report. 2. Components and systems operated during the inspection will be identified in the inspection report. The identified components and systems shall be operated with normal user controls and as conditions permit. If a component or system is operated, it may be conducted without the aid of special protective clothing, exploratory probing, removing materials, testing, measuring, preparing, calculations or using special equipment, including meters or devices of any kind. Testing, measuring, or preparing calculations for any system or component to determine adequacy, capacity, or compliance with any standard is outside the scope of this contract. 3. The term “poor” or “major concern” in regard to a component mean the presence of conspicuous patent defects or material deferred maintenance of the building’s material systems, components, or building equipment as observed during the inspection. This definition specifically excludes deficiencies that may be remedied with routine maintenance, miscellaneous minor repairs, and normal operating maintenance, and excludes conditions that generally do not present material physical deficiencies of the building. 4. Inspector is an expert generalist and not acting as an expert in any SPECIFIC craft or

Page 68: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

trade. The inspector may make recommendations for further evaluation by an individual(s) who is an expert or specialist IN ONE OR MORE SPECIFIC BUILDING COMPONENTS OR SYSTEMS. 5. The inspection is not technically exhaustive. The cost obtaining information or the time required to conduct a technically exhaustive inspection and prepare the inspection report could outweigh the usefulness of the information and could be detrimental to the orderly and timely completion of Client’s transaction. 6. No inspection can wholly eliminate the uncertainty regarding the presence of physical deficiencies and the performance of the building’s systems. Preparation of an inspection report in accordance with this contract is intended to reduce, but not eliminate, the uncertainty regarding the potential for component or system failure and to reduce the potential that such component or system may not be initially observed. Client recognizes the inherent subjective nature of the inspector’s opinions as to issues such as workmanship, quality of original installation, and estimating the remaining useful life of any given component or system. The inspector’s opinions generally are formed without detailed knowledge from those specifically familiar with the component or system’s performance. 7. The inspection report will contain a representative indication of the property condition at the time of the inspection and is dependent on the information available to the inspector at that time. 8. It is the Client’s duty and obligation to exercise reasonable care to protect himself or herself regarding the condition of the building, including those facts that are known to or within the diligent attention and observation of the Client. SCOPE AND LIMITATIONS OF THIS INSPECTION This inspection is limited to a visual observation of the exposed and readily accessible areas of the home. The concealed and inaccessible areas are not included. The following locations are considered inaccessible due to limited height and excluded from this inspection unless otherwise stated:

Crawl space areas less than 18 inches in height

Attic spaces less than 5 feet in height

Spaces under outdoor decks less than 5 feet high Observation includes operation of the systems or components by means of the normal user controls. Dismantling of equipment, and destructive testing is not included. Some specific items are also excluded, and these are listed in the following section. If you feel there is a need for evaluation of any of these items, then you will need to arrange for specific inspections. Items not Included

Page 69: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

1. Recreational, leisure, playground or decorative equipment or appliances including but not limited to pools, hot tubs, saunas, steam baths, landscape lighting, fountains, shrubs, trees, and tennis courts; 2. Cosmetic conditions (wallpapering, painting, carpeting, scratches, scrapes, dents, cracks, stains, soiled or faded surfaces on the structure or equipment, soiled, faded, torn, or dirty floor, wall or window coverings etc.); 3. Noise pollution or air quality in the area; 4. Earthquake hazard, liquefaction, flood plain, soil, slide potential or any other geological conditions or evaluations; 5. Engineering level evaluations on any topic; 6. Existence or non-existence of solder or lead in water pipes, asbestos, hazardous waste, radon, urea formaldehyde urethane, lead paint or any other environmental, flammable or toxic contaminants or the existence of water or airborne diseases or illnesses and all other similar or potentially harmful substances (although the inspector may note the possible existence of asbestos in ceiling texture and furnace duct tape); 7. Zoning or municipal code (e.g. building, fire, housing (existing buildings), mechanical, electrical, plumbing, etc. code) restrictions or other legal requirements of any kind; 8. Any repairs which relate to some standard of interior decorating; 9. Cracked heat exchangers or similar devices in furnaces; 10. Any evaluation which requires the calculation of the capacity of any system or item that is expected to be part of the inspection. Examples include but are not limited to the calculation of appropriate wattage or wiring of kitchen appliances, appropriate sizing of flues or chimneys, appropriate ventilation to combustion-based items (e.g. furnaces, water heaters, fireplaces etc.), appropriate sizing, spacing and spanning of joists, beams, columns, girders, trusses, rafters, studs etc., appropriate sizing of plumbing and fuel lines, etc.; 11. Washers and dryers; 12. Circuit breaker operation; 13. Specialty evaluations such as private sewage, wells, solar heating systems, alarms, intercom systems, central vacuum systems, wood and coal stoves, pre-fab and zero clearance fireplaces, space heaters, sprinkler systems, gas logs, gas lights, elevators and common areas unless these have been specifically added to the inspection description above but only to the degree that the inspector is capable of evaluating these items;

Page 70: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

14. Items that are not visible and exposed including but not limited to concealed wiring, plumbing, water leaks, under bathtubs and shower stalls due to faulty pans or otherwise, vent lines, duct work, exterior foundation walls (below grade or covered by shrubs or wall/paneling, stored goods etc.) and footings, underground utilities, and systems and chimney flues; 15. Evaluations involving destructive testing; 16. Evaluation which requires moving personal goods, debris, furniture, equipment, floor covering, insulation or like materials; 17. Design problems and adequacy or operational capacity, quality or suitability; 18. Fireplace drafting; 19. To prevent damages to units, air conditioning when outside temperature below 60 degrees F or if the unit has not been warmed up or on for at least 24 hours prior to inspection; 20. Any evaluation which would involve scraping paint or other wall coverings; 21. Heating system accessories (e.g. humidifiers, electronic air cleaners etc.); 22. Legal description of property such as boundaries, egress/ingress, etc.; 23. Quality of materials; 24. Conformance with plan specifications or manufacturers specifications; 25. Flood conditions or plains; 26. Any other characteristics or items which are generally not included in a building inspection report on a regular basis. Services for inspecting or evaluating the excluded items listed above may be available from the Inspector for an additional fee or from specialists qualified to inspect or evaluate a particular category or item. Disclaimer In some cases we may recommend your consulting a specialist such as a structural engineer or licensed electrician. Hiring a specialist can be a prudent means of providing some protection of your financial investment in this property. WE DO NOT MAKE ANY TYPE OF WARRANTY OR GUARANTEE AS TO THE CONDITION OF THE PROPERTY. SOME THINGS MAY REMAIN HIDDEN OR BECOME DEFECTIVE AFTER THE INSPECTION. IT IS NOT POSSIBLE TO DETECT

Page 71: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

EVERY DEFECT WITHIN A BUILDING DURING THE COURSE OF A GENERAL INSPECTION. THIS REPORT SHOULD BE USED IN CONJUNCTION WITH, AND NOT A REPLACEMENT FOR , A PRE-CLOSING WALK-THROUGH BY THE CLIENT. THIS INSPECTION IS NOT AN INSURANCE POLICY AGAINST HIDDEN DEFECTS, OR CONDITIONS THAT ARE NOT VISIBLE AND READILY APPARENT AT THE TIME OF INSPECTION. THE COST OF THIS INSPECTION DOES NOT ENTITLE YOU TO ANY TYPE OF PROTECTION FROM HIDDEN FLAWS AND DEFECTS. THIS INSPECTION DOES NOT TRANSFER YOUR ULTIMATE RESPONSIBILITY TO ALL POINT HOME INSPECTIONS. ENVIRONMENTAL CONCERNS: Client acknowledges that what is being contracted for is a building inspection and not an environmental evaluation and the inspection is not intended to detect, identify or disclose any health or environmental concerns regarding this building or property, including, but not limited to, the presence of asbestos, radon, lead, urea formaldehyde, fungi, mold, mildew, PCB’s or other toxic materials or substances in the water, air, soil or building materials. CONFIDENTIAL REPORT: The inspection report to be prepared for the Client is solely and exclusively for the Client’s own information and may not be relied upon by any other person. Client agrees to maintain the confidentiality of the inspection report and agrees not to disclose any part of it to any other person. Client my distribute copies of the inspection report to other persons directly involved in this transaction, but the Client and Inspector do not in any way intend to benefit said other persons directly or indirectly through this Contract, the inspection or the inspection report. CLIENT AGREES TO INDEMNIFY, DEFEND AND HOLD THE INSPECTOR HARMLESS FROM ANY THRID PARTY CLAIMS ARISING OUT OF THE CLIENT’S UNAUTHORIZED DISTRIBUTION OF THE INSPECTION REPORT. LIQUIDATED DAMAGES: IT IS UNDERSTOOD AND AGREES BY AND BETWEEN THE PARTIES HERETO THAT THE INSPECTOR/INSPECTION COMPANY IS NOT AN INSURER, THAT THE PAYMENT FOR THE SUBJECT INSPECTION IS BASED SOLELY ON THE VALUE OF THE SERVICES PROVIDED BY THE INSPECTOR/INSPECTION COMPANY IN THE PREFORMANCE OF THE INSPECTION AND PRODUCTION OF THE INSPECTION REPORT AS DESCRIBED HEREIN, THATIT IS IMPRACTICABLE AND EXTREMELY DIFFICULT TO FIX THE ACTUAL DAMAGES, OF ANY, WHICH MAY RESULT FROM A FAILURE TO PERFORM SUCH SERVICES, AND IN CASE OF FAILURE TO PERFORM SUCH SERVICES AND A RESULTING LOSS, THE CLIENT’S DAMAGES HEREIN SHALL BE LIQUIDATER AND FIXED IN AN AMOUNT EQUAL TO THE INSPECTION FEE PAID MULTIPLIED BY ONE HUNDRED TWENT-FIVE PERCENT (125%) AS

Page 72: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

LIQUIDATED DAMAGES AND NOT AS A PENALTY, AND THIS REMEDY SHALL BE EXCLUSIVE. GENERAL PROVISIONS: A. This inspection contract, the inspection, and the inspection report do not constitute a warranty, guarantee, or insurance policy of any kind whatsoever. B. No legal action or proceeding of any kind, including in tort or contract can be commenced against Inspector/Inspection Company, or its officers, agents or employees more than one year after the date of the subject inspection. Time is expressly of the essence herein. THIS TIME PERIOD IS SHORTER THAN OTHERWISE PROVIDED BY LAW. C. In the event the Client discovers a material physical deficiency in a component, system or equipment of the building that was not identified and reported by the Inspector, Client shall so notify the Inspector in writing and allow Inspector and/or Inspector’s designated representative to re-inspect and document the condition(s) of the material physical deficiency prior to making any repair, alteration, or replacement to said physical deficiency. D. Should any provision of this contract be held by a court of competent jurisdiction to be either invalid or unenforceable, the remaining provisions of this contract shall remain in full force and effect, unimpaired by the court’s holding. E. This contract shall be binding upon and inure to the benefit of only the undersigned parties and their heirs, successors and assigns. F. This contract constitutes the entire integrated agreement between the parties hereto pertaining to the subject matter hereof, and may be modified only by a written agreement signed by all of the parties hereto. No oral agreements, understanding, or representations shall change, modify, or amend any part of this contract. G. Each party signing this contract warrants and represents that he/she has the full capacity and authority to execute this contract on behalf of the named party whether it is a corporation, partnership, or other entity. If this contract is executed on behalf of the Client by a third party, the person executing this contract expressly represents to the Inspector that he/she has the full and complete authority to execute this contract on the Client’s behalf and to fully and completely bind the Client to all of the terms, conditions, limitations, exceptions and exclusions of this contract. This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. FOLLOW-UP INSPECTION POLICY Generally we discourage follow-up inspections for these reasons

Page 73: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

1. Quality of repairs

If repairs are made to a property based on the results of an inspection, the work should be performed by qualified contractors, not the seller. By qualified, we mean licensed, bonded, state-certified where applicable and with a reasonable amount of experience. Contractors providing repairs should provide legible documentation in the form of work orders and/or receipts. If repairs are made in this way, then there's generally no need for a follow-up inspection. Additionally, it may be better to negotiate a lower price on your home and have repairs made by contractors you choose rather than the seller making repairs as cheaply as possible. ________________________________________ As a part of our service, we sometimes provide approximate, cost of repair estimates for particular items. These estimates should be considered as background information only. It is beyond the scope of this inspection and report to supply you with accurate repair costs. Such estimates should be supplied by contractors who specialize in this type of work. Our estimates should be used only as guidelines. If you intend to negotiate the price of this property based on defects found during this inspection, we strongly suggest you obtain one or more written bids from a licensed contractor(s). It is a conflict of interest for Strong Foundations Home Inspection to recommend any specific contractor.

Page 74: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Life Expectancy Charts for Homes PLEASE NOTE: These life expectancies have been determined through research and testing based on regular recommended maintenance and conditions of normal wear and tear, and not extreme weather or other conditions, neglect, over-use or abuse. Therefore, they should be used as guidelines only, and not relied upon as guarantees or warranties. Surface preparation and paint quality are the most important determinants of a paint's life expectancy. Ultraviolet (UV) rays via sunshine can shorten life expectancy. Additionally, conditions of high humidity indoors or outdoors can affect the lifespan of these components, which is why they should be inspected and maintained seasonally.

ADHESIVES, CAULK & PAINTS

YEARS

Caulking (interior & exterior) 5 to 10 Construction Glue 20+ Paint (exterior) 7 to 10 Paint (interior) 10 to 15 Roofing Adhesives/Cements 15+ Sealants 8 Stains 3 to 8 Appliance life expectancy depends to a great extent on the use it receives. Furthermore, consumers often replace appliances long before they become worn out due to changes in styling, technology and consumer preferences.

APPLIANCES YEARS Air Conditioner (window)

5 to 7

Compactor (trash) 6 Dehumidifier 8 Dishwasher 9 Disposal (food waste) 12 Dryer Vent (plastic) 5 Dryer Vent (steel) 20 Dryer (clothes) 13 Exhaust Fans 10 Freezer 10 to 20 Gas Oven 10 to 18 Hand Dryer 10 to 12 Humidifier (portable) 8 Microwave Oven 9 Range/Oven Hood 14 Electric Range 13 to 15

Page 75: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Gas Range 15 to 17 Refrigerator 9 to 13 Swamp Cooler 5 to 15 Washing Machine 5 to 15 Whole-House Vacuum System 20 Modern kitchens today are larger and more elaborate. Together with the family room, they now form the “great room.”

CABINETRY & STORAGE YEARS Bathroom Cabinets 50+ Closet Shelves 100+ Entertainment Center/Home Office

10

Garage/Laundry Cabinets 70+ Kitchen Cabinets 50 Medicine Cabinet 25+ Modular (stock manufacturing-type)

50

Walls and ceilings last the full lifespan of the home.

CEILINGS & WALLS YEARS Acoustical Tile Ceiling 40+ (older than 25 years may

contain asbestos) Ceramic Tile 70+ Concrete 75+ Gypsum 75 Wood Paneling 20 to 50 Suspended Ceiling 25+ Natural stone countertops, which are less expensive than they were just a few years ago, are becoming more popular, and one can expect them to last a lifetime. Cultured marble countertops have a shorter life expectancy, however.

COUNTERTOPS YEARS Concrete 50 Cultured Marble 20 Natural Stone 100+ Laminate 20 to 30 Resin 10+ Tile 100+ Wood 100+

Page 76: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Decks are exposed to a wide range of conditions in different climates, from wind and hail in some areas, to relatively consistent, dry weather in others. See FASTENERS & STEEL section for fasteners.

DECKS YEARS Deck Planks 15 Composite 8 to 25 Structural Wood 10 to 30 Exterior fiberglass, steel and wood doors will last as long as the house, while vinyl and screen doors have a shorter life expectancy. The gaskets/weatherstripping of exterior doors may have to be replaced every 5 to 8 years.

DOORS YEARS Closet (interior) 100+ Fiberglass (exterior) 100+ Fire-Rated Steel (exterior) 100+ French (interior) 30 to 50 Screen (exterior) 30 Sliding Glass/Patio (exterior) 20 (for roller wheel/track

repair/replacement) Vinyl (exterior) 20 Wood (exterior) 100+ Wood (hollow-core interior) 20 to 30 Wood (solid-core interior) 30 to 100+ Copper-plated wiring, copper-clad aluminum, and bare copper wiring are expected to last a lifetime, whereas electrical accessories and lighting controls, such as dimmer switches, may need to be replaced after 10 years. GFCIs could last 30 years, but much less if tripped regularly. Remember that faulty, damaged or overloaded electrical circuits or equipment are the leading cause of house fires, so they should be inspected regularly and repaired or updated as needed.

ELECTRICAL YEARS Accessories 10+ Arc-Fault Circuit Interrupters (AFCIs)

30

Bare Copper 100+ Bulbs (compact fluorescent) 8,000 to 10,000+ hours Bulbs (halogen) 4,000 to 8,000+ hours Bulbs (incandescent) 1,000 to 2,000+ hours Bulbs (LED) 30,000 to 50,000+ hours Copper-Clad Aluminum 100+ Copper-Plated 100+

Page 77: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Fixtures 40 Ground-Fault Circuit Interrupters (GFCIs)

up to 30

Lighting Controls 30+ Residential Propane Backup Generators

12

Service Panel 60 Solar Panels 20 to 30 Solar System Batteries 3 to 12 Wind Turbine Generators 20 Floor and roof trusses and laminated strand lumber are durable household components, and engineered trim may last 30 years.

ENGINEERED LUMBER YEARS Engineered Joists 80+ Laminated Strand Lumber 100+ Laminated Veneer Lumber 80+ Trusses 100+ Fastener manufacturers do not give lifespans for their products because they vary too much based on where the fasteners are installed in a home, the materials in which they're installed, and the local climate and environment. However, inspectors can use the guidelines below to make educated judgments about the materials they inspect.

FASTENERS, CONNECTORS & STEEL

YEARS

Adjustable Steel Columns 50+ Fasteners (bright) 25 to 60 Fasteners (copper) 65 to 80+ Fasteners (galvanized) 10+ Fasteners (electro-galvanized) 15 to 45 Fasteners (hot-dipped galvanized)

35 to 60

Fasteners (stainless) 65 to 100+ Steel Beams 200+ Steel Columns 100+ Steel Plates 100+ Flooring life is dependent on maintenance and the amount of foot traffic the floor endures.

FLOORING YEARS All Wood Floors 100+ Bamboo 100+ Brick Pavers 100+

Page 78: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Carpet 8 to 10 Concrete 50+ Engineered Wood 50+ Exotic Wood 100+ Granite 100+ Laminate 15 to 25 Linoleum 25 Marble 100+ Other Domestic Wood 100+ Slate 100 Terrazzo 75+ Tile 75 to 100 Vinyl 25 Concrete and poured-block footings and foundations will last a lifetime, assuming they were properly built. Waterproofing with bituminous coating lasts 10 years, but if it cracks, it is immediately damaged.

FOUNDATIONS YEARS Baseboard Waterproofing System 50 Bituminous-Coating Waterproofing

10

Concrete Block 100+ Insulated Concrete Forms (ICFs) 100 Permanent Wood Foundation (PWF; treated)

75

Post and Pier 20 to 65 Post and Tensioned Slab on Grade

100+

Poured-Concrete Footings and Foundation

100+

Slab on Grade (concrete) 100 Wood Foundation 5 to 40 Framing and structural systems have extended longevities; poured-concrete systems, timber frame houses and structural insulated panels will all last a lifetime.

FRAMING YEARS Log 80 to 200 Poured-Concrete Systems 100+ Steel 100+ Structural Insulated Panels (SIPs)

100+

Timber Frame 100+

Page 79: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

The quality and frequency of use will affect the longevity of garage doors and openers.

GARAGES YEARS Garage Doors 20 to 25 Garage Door Openers 10 to 15 Home technology systems have diverse life expectancies and may have to be upgraded due to evolution in technology.

HOME TECHNOLOGY YEARS Built-In Audio 20 Carbon Monoxide Detectors* 5 Doorbells 45 Home Automation System 5 to 50 Intercoms 20 Security System 5 to 20 Smoke/Heat Detectors* less than 10 Wireless Home Networks 5+ * Batteries should be changed at least annually. Thermostats may last 35 years but they are usually replaced before they fail due to technological improvements.

HVAC YEARS Air Conditioner (central) 7 to 15 Air Exchanger 15 Attic Fan 15 to 25 Boiler 40 Burner 10+ Ceiling Fan 5 to 10 Chimney Cap (concrete)

100+

Chimney Cap (metal) 10 to 20 Chimney Cap (mortar) 15 Chimney Flue Tile 40 to 120 Condenser 8 to 20 Dampers 20+ Dehumidifier 8 Diffusers, Grilles and Registers 25 Ducting 60 to 100 Electric Radiant Heater 40 Evaporative Cooler 15 to 25

Page 80: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Furnace 15 to 25 Gas Fireplace 15 to 25 Heat Exchanger 10 to 15 Heat Pump 10 to 15 Heat-Recovery Ventilator 20 Hot-Water and Steam-Radiant Boiler

40

Humidifier 12 Induction and Fan-Coil Units 10 to 15 Thermostats 35 Ventilator 7 As long as they are not punctured, cut or burned and are kept dry and away from UV rays, cellulose, fiberglass and foam insulation materials will last a lifetime. This is true regardless of whether they were installed as loose-fill, housewrap or batts/rolls.

INSULATION & INFILTRATION BARRIERS

YEARS

Batts/Rolls 100+ Black Paper (felt paper) 15 to 30 Cellulose 100+ Fiberglass 100+ Foamboard 100+ Housewrap 80+ Liquid-Applied Membrane 50 Loose-Fill 100+ Rockwool 100+ Wrap Tape 80+ Masonry is one of the most enduring household components. Fireplaces, chimneys and brick veneers can last the lifetime of the home.

MASONRY & CONCRETE YEARS Brick 100+ Insulated Concrete Forms (hybrid block)

100+

Concrete Masonry Units (CMUs) 100+ Man-Made Stone 25 Masonry Sealant 2 to 20 Stone 100+ Stucco/EIFS 50+ Veneer 100+

Page 81: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Custom millwork and stair parts will last a lifetime and are typically only upgraded for aesthetic reasons.

MOLDING, MILLWORK & TRIM

YEARS

Attic Stairs (pull-down) 50 Custom Millwork 100+ Pre-Built Stairs 100+ Stair Parts 100+ Stairs 100+ The lifetime of any wood product depends heavily on moisture intrusion.

PANELS YEARS Flooring Underlayment 25 Hardboard 40 Particleboard 60 Plywood 100 Softwood 30 Oriented Strand Board (OSB) 60 Wall Panels 100+ The quality of plumbing fixtures varies dramatically. The mineral content of water can shorten the life expectancy of water heaters and clog showerheads. Also, some finishes may require special maintenance with approved cleaning agents per the manufacturers in order to last their expected service lives.

PLUMBING, FIXTURES & FAUCETS

YEARS

ABS and PVC Waste Pipe 50 to 80 Accessible/ADA Handles 100+ Acrylic Kitchen Sink 50 Cast-Iron Bathtub 100 Cast-Iron Waste Pipe (above ground)

60

Cast-Iron Waste Pipe (below ground)

50 to 60

Concrete Waste Pipe 100+ Copper Water Lines 70 Enameled Steel Kitchen Sink 5 to 10+ Faucets and Spray Hose 15 to 20 Fiberglass Bathtub and Shower 20 Gas Lines (black steel) 75 Gas Lines (flex) 30

Page 82: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Hose Bibs 20 to 30 Instant (on-demand) Water Heater

10

PEX 40 Plastic Water Lines 75 Saunas/Steam Room 15 to 20 Sewer Grinder Pump 10 Shower Enclosure/Module 50 Shower Doors 20 Showerheads 100+ (if not clogged by

mineral/other deposits) Soapstone Kitchen Sink 100+ Sump Pump 7 Toilet Tank Components 5 Toilets, Bidets and Urinals 100+ Vent Fan (ceiling) 5 to 10 Vessel Sink (stone, glass, porcelain, copper)

5 to 20+

Water Heater (conventional) 6 to 12 Water Line (copper) 50 Water Line (plastic) 50 Water Softener 20 Well Pump 15 Whirlpool Tub 20 to 50 Radon systems have but one moving part: the radon fan.

RADON SYSTEMS YEARS Air Exchanger 15 Barometric Backdraft Damper/Fresh-Air Intake

20

Caulking 5 to 10 Labeling 25 Manometer 15 Piping 50+ Radon Fan 5 to 8 The life of a roof depends on local weather conditions, building and design, material quality, and adequate maintenance. Hot climates drastically reduce asphalt shingle life. Roofs in areas that experience severe weather, such as hail, tornadoes and/or hurricanes, may also experience a shorter-than-normal lifespan overall or may incur isolated damage that requires repair in order to ensure the service life of the surrounding roofing materials.

ROOFING YEARS

Page 83: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Aluminum Coating 3 to 7 Asphalt (architectural) 30 Asphalt Shingles (3-tab) 20 BUR (built-up roofing) 30 Clay/Concrete 100+ Coal and Tar 30 Copper 70+ EPDM (ethylene propylene diene monomer) Rubber

15 to 25

Fiber Cement 25 Green (vegetation-covered) 5 to 40 Metal 40 to 80 Modified Bitumen 20 Simulated Slate 10 to 35 Slate 60 to 150 TPO 7 to 20 Wood 25 Outside siding materials typically last a lifetime. Some exterior components may require protection through appropriate paints or sealants, as well as regular maintenance. Also, while well-maintained and undamaged flashing can last a long time, it is their connections that tend to fail, so seasonal inspection and maintenance are strongly recommended.

SIDINGS, FLASHING & ACCESSORIES

YEARS

Aluminum Gutters, Downspouts, Soffit and Fascia

20 to 40+

Aluminum Siding 25 to 40+ Asbestos Shingle 100 Brick 100+ Cementitious 100+ Copper Downspouts 100 Copper Gutters 50+ Engineered Wood 100+ Fiber Cement 100+ Galvanized Steel Gutters/Downspouts

20

Manufactured Stone 100+ Stone 100+ Stucco/EIFS 50+ Trim 25 Vinyl Gutters and Downspouts 25+ Vinyl Siding 60 Wood/Exterior Shutters 20

Page 84: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

Site and landscaping elements have life expectancies that vary dramatically.

SITE & LANDSCAPING YEARS American Red Clay 100+ Asphalt Driveway 15 to 20 Brick and Concrete Patio 15 to 25 Clay Paving 100+ Concrete Walks 40 to 50 Controllers 15 Gravel Walks 4 to 6 Mulch 1 to 2 Polyvinyl Fencing 100+ Sprinkler Heads 10 to 14 Underground PVC Piping 60+ Valves 20 Wood Chips 1 to 5 Wood Fencing 20 Swimming pools are composed of many systems and components, all with varying life expectancies.

SWIMMING POOLS YEARS Concrete Shell 25+ Cover 7 Diving Board 10 Filter and Pump 10 Interior Finish 10 to 35 Pool Water Heater 8 Vinyl Liner 10 Waterline Tile 15+ Aluminum windows are expected to last between 15 and 20 years, while wooden windows should last nearly 30 years.

WINDOWS YEARS Aluminum/Aluminum-Clad 15 to 20 Double-Pane 8 to 20 Skylights 10 to 20 Vinyl/Fiberglass Windows 20 to 40 Window Glazing 10+ Wood 30+ Note: Life expectancy varies with usage, weather, installation, maintenance and quality of

Page 85: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

materials. This list should be used only as a general guideline and not as a guarantee or warranty regarding the performance or life expectancy of any appliance, product, system or component. Evaluations are made as to the present age, and remaining economic life of an item, i.e. water heaters, roofs, plumbing, furnaces, etc. These evaluations are based on visual observation, industry averages and prior experience. THEY ARE NOT OFFERED AS A WARRANTY OR CERTIFICATION OF REMAINING LIFE.

Page 86: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

HOME MAINTENANCE CHECK LIST: Monthly: 1. Clean any removable dishwasher filters. 2. Purge food disposal by filling the kitchen sink with clean water, then turn on the device until the water drains through. 3. Wash refrigerator/freezer interior walls and door gaskets with a solution of one quart of warm water to two tablespoons of baking soda and wipe dry. 4. Vacuum and clean “return” air ducts/grills. 5. Inspect lighting fixtures and replace any burned-out bulbs. 6. Clean clothes dryer lint trap and/or duct for better energy efficiency and to decrease the risk of fire. Quarterly: 1. Inspect and service doors by cleaning and lubricating latches, hinges or replacing weather-stripping as might be required. 2. Inspect and repair, if necessary, exterior caulking and finish around windows, doors, and siding. 3. Replace/clean, at least quarterly, furnace, heating and cooling system filters. 4. Re-tighten knobs and pulls on cabinets. Clean and lubricate drawer tracks and guides. Semi-annually: 1. Inspect and test smoke and carbon monoxide alarms. Replace backup batteries as might be required. 2. Test (GFCI) ground fault circuit interrupters and (AFCI) arc fault breakers. 3. Inspect and maintain/clean gutters and downspouts. Runoff water must be directed away from the home. 4. Inspect attics and substructure areas for rodent droppings or other signs of pests or leaks/standing water, etc. 5. Prior to the beginning of the rainy season, test sump pumps for adequacy and function. 6. Look for moisture or decay, outside and inside the house, where flat surface decks and landing attach to the house. This is especially important if the landings do not have proper flashings. 7. Clean range hood fan grills and housings. 8. Use a vacuum cleaner to remove dust on coils behind the refrigerator/freezer. Annually: 1. Licensed contractor to inspect and service heating and air-conditioning systems. 2. Professional contractor to inspect and service wood burning appliances and chimneys. 3. Seal any foundation cracks. 4. Inspect, clean and lubricate garage vehicle door tracks and test auto-reverse functions. 5. Clean and lubricate sliding glass door and window tracks. 6. Inspect exterior paint for cracking and wear. Repaint, caulk and seal as needed.

Page 87: FAIRA TRANSPARENCY REPORTS 1635 112th St S, Tacoma, WA …€¦ · 33: - The system water pressure, as measured at the exterior hose bibs, is excessive. This can result in unnecessary

©2018 Strong Foundations Home Inspection

7. Reseal, as required, wood decks and landings. 8. Inspect, for water damage, pests or rot, any substructure and attic areas. 9. Inspect roof flashings, chimney caps, shingles. 10. Inspect outside electrical service lines for damage, exposed wires or proximity to tree limbs. 11. Inspect all supply hoses at sinks, toilets and washing machines. 12. Clean and repair caulking or grout in bathrooms or kitchens. 13. Clean bathroom exhaust fan blades and grills. 14. Inspect all electric coeds and replace as needed. 15. Change water filters and have fresh water systems professionally services. Tips for keeping drains clear: 1. Pour a pot of hot water down the drain once a week to help clear away fat or grease that may have built-up in the drain line or the P-trap. 2. If a drain is clogged, try pouring 1/2 cup of white vinegar down the drain. Cover the drain and let the mixture sit for a few minutes. Then pour a pot of hot water down the drain. General Safety tips: Ensure that you know where the following items are located: 1. Emergency contact telephone numbers. 2. Fire extinguishers and water hose pipes. 3. Heating gas/fuel main shut off valve. 4. Main electrical disconnect circuit breaker (breaker box/service panel). 5. Main drain line clean-out. 6. Main water shut-off valve. 7. All window and door exits.