F A B R A L A R C H I T E C T U R A L S Y S T E M S

It’s time to look at architectural panels in a whole

new light. As a company, we stand strong as an

industry innovator, manufacturer and one of the

best resources in the ield. Our four decades

of panel design and quality manufacturing, along

with nationwide facilities, place Fabral in a unique

position to serve customers large and small and

provide them with on-site ield support and

technical advice.

Fabral maintains a broad range of product designs

and color choices that are not only architecturally

appealing but also congruent with “Green Building”

guidelines. Fabral products are manufactured from

substrates that utilize a signiicant amount of

recycled material and are coated with Flurobond™

High Deinition Coating systems which allow

many of the colors to relect a signiicant amount

of heat away from the structure. In fact, virtually

every panel that Fabral makes carries the

Energy Star® approval for energy eiciency. Fabral

panels also earn U.S. Green Building Council’s

Leadership in Energy and Environmental Design

(LEED) points, which count toward obtaining

“Green Building” certiication for energy eicient,

environmentally-friendly structures.

Aesthetically pleasing, durable and sustainable,

Fabral architectural panels ofer contractors

and architects the inest choice of materials and

customer service on the market today.

ST

AN

DI

NG

S

EA

M

RO

OF

P

AN

EL

S

2

Cover Project: Lynx Regional Center, Central Florida Regional Transportation Authority, Orlando, FLPanel: Deep Rib IVColor: Kynar Bright Silver

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS T A N D ‘ N S E A M ®

2 1/2" 2 1/4"

12" or 16"

Wind Uplift

UL90 #275, 275A, 275B

UL2218 Class 4 impact

ASTM E330/ASTM E1592 24 ga allowable load of 69.70 psf @ 5'

24 ga allowable load of 95.76 psf @ 2.5'

22 ga allowable load of 87.88 psf @ 5'

.032" AL allowable load of 48.48 psf @ 5'

.032" AL allowable load of 66.67 psf @ 2.5'

.040" AL allowable load of 66.67 psf @ 5'

.040" AL allowable load of 82.42 psf @ 2.5'

MIAMI DADE NOA 05-0405.02 (steel) 06-0307.03 (aluminum)

Air Iniltration

ASTM E283 .006 @20 psf

ASTM E1680 .000 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1646 no water @ 20 psf

Minimum Roof Slope

1/2:12

Available Widths

12" and 16"

Standard Lengths

6' to 47' (field forming available for 16" panel only) 2 1/2" 2 1/4"

3

• A high-performance, structural standing seam roof

system for the most demanding application

• Test reports conirm that Stand ‘N Seam has the highest wind uplift resistance of any standing seam panel available on the market

• Unique one-piece stainless steel clip design does not fold into side joint of panel, allowing unrestricted thermal movement

• Side joints are double lock-seamed with an electric

seaming machine, ensuring weathertightness

• Factory or ield forming by a portable roll-former provides continuous long-length panels from ridge to eave and eliminates unsightly end-laps. Field forming available only by qualiied Fabral operators

• Factory applied sealant is standard

• ASTM E1592 and Multiple UL90 ratings in both steel and aluminum for applications over open framing or solid substances

• Fully tested performance for air and water iniltration

• Multiple UL ire resistant assemblies available

• Miami Dade County tested and approved in aluminum

and steel

• UL Class A ire rated

• Class 4 impact rating

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AT H I N S E A M

• Engineered snap-together high-performance panel

• Widely speciied classic thin seam design

• Panel legs continuously interlock together, not just to the clip, for added strength

• Multiple wind uplift tests including ASTM E1592 and UL90

• Factory applied seam sealant is standard

• Shadow lines are included on standard panel proile

• Optional panel shapes include stifening ribs, striations

or smooth panel pans

• Can be installed over open framing or solid substrates

• Concealed clips provide unlimited thermal movement

• Factory or ield forming by a portable roll-former

provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualiied Fabral operators

• Available with batten for bolder seam lines

• Tapered panel available (without stifening beads &

shadowlines)

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

12", 16" or 18" COVERAGE

1 3

/4"

Wind Uplift

UL90 #303, 359, 359A, 343, 417

ASTM E1592 22 ga allowable load of 40.61 psf @ 5'

22 ga allowable load of 48.48 psf @ 2.5'

24 ga allowable load of 29.70 psf @ 5'

24 ga allowable load of 30.30 psf @ 2.5'

Air Iniltration

ASTM E283 .009 @ 6.24 psf

Water Penetration

ASTM E331 no water @ 15 psf

Minimum Roof Slope

1:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

4

SHADOWLINES STANDARD

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS L I M S E A M ®

12" or 16" COVERAGE1 1/2"

Wind Uplift

UL90 #274, 274A, 369

UL2218 Class 4 impact

ASTM E1592 24 ga allowable load of 48.48 psf @ 2.5'

Air Iniltration

ASTM E283 .09 @ 1.57 psf

ASTM E1680 .00 @ 20 psf

Water Penetration

ASTM E331 no water @ 25 psf

ASTM E1646 no water @ 12 psf

Minimum Roof Slope

1:12

Available Widths

12" and 16"

Standard Lengths

6' to 47'

1 1/2"

5

• An economical, high-performance standing seam design

• Unique one-piece stainless steel clip allows for unlimited thermal movement and reduced panel pan uplift under negative load

• Panel legs continuously interlock together, not just to the clip

• Multiple wind uplift tests including ASTM E1592, UL60 (aluminum) and UL90 (steel) ratings

• Factory applied seam sealant is standard

• Usually installed over a solid substrate, but can be

installed over open framing at a 3' maximum on center spacing

• UL Class A ire rated

• Class 4 impact rated

• .032" and .040" aluminum and 24 gauge and 22 gauge steel and copper are available

• Shadowlines available

SHADOWLINES AVAILABLE

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AP R E S T I G E ™ ( f o r m e r l y A m p - L o k )

• Mechanical seamed structural standing seam panel

• 90 and 180 degree seaming available

• Concealed two-piece panel clip allows for thermal

expansion

• Multiple wind uplift tests including FM, ASTM E1592 and UL90

• Factory applied seam sealant is standard

• Shadow lines are included on standard panel proile

• Optional panel shapes include stifening ribs or

smooth panel pans

• Can be installed over open framing or solid substrates

• Curved panels are available to a 10' minimum radius

• Tapered panels available (without stifening beads &

shadowlines)

• Factory or ield forming by a portable roll-former

provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualiied Fabral operators

• Step down shoulders available

• 24 gauge and 22 gauge steel are available

16"

2"

Wind Uplift

UL90 #90, 176, 180, 238, 548, 549

ASTM E1592 Single Lock:

24 ga 18" allowable load of 35.15 @ 5'

24 ga 18" allowable load of 29.09 @ 2.5'

Double Lock:

24 ga 18" allowable load of 58.79 @ 5'

24 ga 18" allowable load of 67.88 @ 2.5'

Factory Mutual FM Class I-90 tested and approved

Air Iniltration

ASTM E283 .01 @ 15 psf

Water Penetration

ASTM E331 no water @ 6.24 psf

Minimum Roof Slope

1:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

6

SHADOWLINES STANDARD

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AT - R I B ®

• Symmetrical design allows ease of installation for dificult hip, ridge and valley condition

• Mechanically-seamed cap strip with factory-applied sealant tape assures a weather-tight seam

• One-piece concealed clip allows for thermal movement

• Panels can be tapered

• Multiple UL90 ratings for steel panels

• Can be installed over open framing or solid substrate

• Field forming available upon special request

• UL Class A ire rated

• .032" and .040" aluminum and 24 gauge and 22

gauge steel are available

12", 16", & 18" COVERAGE

1 1/2"

2 3/8" 1 /1 6 " x 1 " RIBS STANDARD

FACTORY APPLIED SEALANT TAPE

Wind Uplift

UL90 #103, 139, 415, 416

ASTM E1592 24 ga allowable load of 18.9 @ 5'

24 ga allowable load of 36.36 @ 2.5'

.040 allowable load of 23.6 @ 5'

Air Iniltration

ASTM E283 .015 @ 6.24 psf

Water Penetration

ASTM E331 no water @ 6.24 psf

Minimum Roof Slope

1/2:12

Available Widths

12", 16" and 18"

Standard Lengths

6' to 47' (field forming available)

2 1 / 2 " S S R

• Classic style with narrow batten seams

• Designed for durability against rain, snow and wind

• Concealed clip fastening system

• Easy installation

• May be disassembled without damaging panels or caps

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

• Heavier gauges available (18 ga, 20 ga)

18" COVERAGE

4 15/16" 6" 4 15/16"

2 7/16"

Wind Uplift

UL90 #190, 190B

Air Iniltration

ASTM E283 .000 @ 20 psf

ASTM E1680 .019 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1546 no water @ 20 psf

Minimum Roof Slope

1/2:12

Standard Lengths

6' to 51'

7

GASKET

LI

NE

R

PA

NE

L

&

SP

EC

IA

LT

Y

PR

OD

UC

TS

30

Project: Soaring Wings Residence, Austin, TXPanel: CopperCraftÆ Coil

Project: Soaring Wings Residence, Austin, TXPanel: CopperCraftÆ Coil

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS N A P - O N - S E A M

• Classic snap-on-seam two-component design

• 1" nominal seam height using a 1" seam cover

• Allows for easy removal of individual panels for repairs

• Concealed clip allows for unlimited thermal movement

• Panel can be curved to a minimum 5'–0" radius

• Must be installed over a solid substrate

• Panels can be tapered (without stifening beads &

shadowlines)

• Easy to install

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

•Shadowlines & stifening beads available

12", 16", 18", or 20"

PAN

3/8"

1"

R 1/16"

3/4"

Wind Uplift

ASTM E1592 24 ga allowable load of 59.39 @ 1'–3"

24 ga alllowable load of 42.42 @ 2'–6"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

S N A P - O N - B A T T E N

• Classic snap-on wide batten design providing bold

aesthetic design

• Ideal for mansards with a slope transition to vertical

fascia

• Easy to install and perform knuckle joint detail

• Concealed clip allows for unlimited thermal movement

• Must be installed over a solid substrate

• Panels can be tapered with limitations due to batten width

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

11 1/8"

1 1/2"

FOR 12" COVERAGE

(SIMILARLY FOR OTHER WIDTH PANELS)

PAN

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

1"

3/8"

1" SEAM WITH CAP AND CLIP

7/8"

CAP

1 9/16"

1 7/8"

SEAM WITH CAP AND CLIP

1 9/16"

1 7/8"

CAP9

SHADOWLINES AVAILABLE

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS N A P - O N - S E A M H I G H P R O F I L E

• High proile snap-on-seam

• 1 3/4" nominal seam height using a 1" seam cover

• Non-integral two piece construction

• Allows for easy removal of individual panels for repairs

• Concealed clip allows for thermal movement

• Panels can be tapered

• Easy to install

• UL Class A ire rated

• .032" and .040" aluminum and 24 gauge and 22 gauge steel are available

12", 16", 18", or 20"

PAN

3/8"

1 3/4"

R1/16"

1 1/2"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

Panels 6' to 47'

Battens 6' to 30'

H I G H S E A M

• Economical snap-together standing seam panel

• Non-structural design must be installed over solid sub-strate

• 1 1/2" nominal seam height

• Concealed clip allows for thermal movement

• UL90 rated over plywood

• Easy installation

• Shadowlines & stifening beads available

• Panels can be tapered (without stifening beads &

shadowlines)

• .032" aluminum and 24 gauge steel are available

1" SHADOWLINES AVAILABLE

12", 16", 18" or 20" COVERAGE

1 1

/2"

Wind Uplift

UL90 #370

Minimum Roof Slope

2:12

Available Widths

12", 16", 18" and 20"

Standard Lengths

6' to 47'

1 3/4"

3/8"

1 3/4" SEAM WITH CAP AND CLIP

7/8"

CAP

10

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AG R A N D C U R V E ™

• Engineered for durability and lexibility

• Narrow seam cover provides contemporary aesthetics

• 1 11/16" seam cover provides a bolder shadow line

• Seam cover continuously interlock to panel pan

• Available in steel, aluminum and copper substrates

• Clips provide unlimited thermal movement

• Panels can be curved to a minimum 15'–0" radius

• Factory or ield forming by a portable roll-former

provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualiied Fabral operators

• .032" aluminum and 24 gauge steel are available

12" COVERAGE

16" COVERAGE

5"1"

1"

G R A N D B A T T E N

• Engineered for durability and lexibility

• Wide batten caps add a bold architectural aesthetic to

roof lines

• Battens continuously interlock to panel pan

• Available in steel, aluminum and copper substrates

• Clips provide unlimited thermal movement

• Factory or ield forming by a portable roll-former

provides continuous long-length panels from ridge to eave and eliminates unsightly end laps. Field forming available only by qualiied Fabral operators

• .032" aluminum and 24 gauge steel are available

18" COVERAGE

24" COVERAGE

5"

1"

7"

1"

Wind Uplift

ASTM E1592 24 ga allowable load of 32.12 psf @ 1'–3"

24 ga allowable load of 21.21 psf @ 3'–9"

Minimum Roof Slope

3:12

Available Widths

12", 16", 18" and 24"

Standard Lengths

Factory Formed 6' to 51' (field forming available)

11/16"

1 11/16"

2 1/4"

2"

Wind Uplift

UL90 #585

ASTM E1592 24 ga allowable load of 52.12 psf @ 1'–3"

24 ga allowable load of 33.33 psf @ 3'–9"

Minimum Roof Slope

3:12

Available Widths

12", 16" and 18"

Standard Lengths

Factory Formed 6' to 51' (field forming available)

11

12

Project: Snyderville Recreation Center, Park City, UTPanel: Stand �N SeamÆ, Decor-FlushÆ, & Hefti-RibÆ

Color: Pewter & Custom Kynar Green

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AI P S E A M 3

• Classic mechanical seamed trapezoidal panel design

• Designed for low slope industrial applications

• Ideal for high-performance Pre-Engineered Metal Buildings

• 3" nominal seam height — 24" seam centers

• 180 and 360 degree seaming available

• Factory applied sealant standard

• Concealed clip allows for thermal movement

• Normally installed over open framed structures

• 24 gauge and 22 gauge steel are available

24"

3 1

/64"

Wind Uplift

UL90 #93, 210A

ASTM E1592 24 ga allowable load

360º Seam of 30.91 psf @ 5'–0"

24 ga allowable load of 60.18 psf @ 1'–3"

22 ga allowable load of 48.18 psf @ 5'–0"

22 ga allowable load of 90.73 psf @ 1'–3"

Factory Mutual FM Class I-90 tested and approved

Air Iniltration

ASTM E283 .006 @ 20 psf

ASTM E1680 .000 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1646 no water @ 20 psf

Minimum Roof Slope

1/2:12

Available Width

24"

Standard Lengths

6' to 47'

I P S N A P 3

• Classic engineered snap-together trapezoidal panel design

• Designed for low slope industrial applications

• Ideal for Pre-Engineered Metal Buildings and Mini Storage Structures

• 3" nominal seam height — 24" seam centers

• Factory applied sealant standard

• Concealed clip allows for thermal movement

• Normally installed over open framed structures

• 24 gauge and 22 gauge steel are available

24"

3 1

/64"

Wind Uplift

UL90 #93, 210A

ASTM E1592 24 ga 24" wide

22 ga 24" wide

Air Iniltration

ASTM E283 .006 @ 20 psf

ASTM E1680 .000 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

ASTM E1646 no water @ 20 psf

Minimum Roof Slope

1/2:12

Available Width

24"

Standard Lengths

6' to 47' 13

S T A N D I N G S E A M R O O F P A N E L S

T E C H N I C A L D A T AS E A M R I B 3 2 4

• High proile mechanical seamed standing seam panel

• Designed for low or high slope industrial applications

• Ideal for complex roof plans on Pre-Engineered Metal

Buildings and Mini Storage applications where valley conditions challenge trapezoidal panels

• Wide seam on centers speed panel installation

• Panel leg is seamed to a 45 degree angle locking to the panel clip

• Factory applied sealant standard

• Three pronounced stifening ribs add rigidity to panel pan

• Concealed two piece clip allows for thermal movement

• Normally installed over open framed structures

• Panel can be reverse run and used as a Liner Panel

• 24 gauge and 22 gauge steel are available

3"

3"

24"

PANEL OPTIONSMOOTH

Wind Uplift

UL90 #372, 372A

Minimum Roof Slope

1/2:12

Available Width

24"

Standard Lengths

6' to 47'

14

15

Project: Historic City Market Building, Roanoke, VAPanel: Fabral CoilColor: Kynar Patina Green

Project: Airport Car Canopies, Savannah, GAPanel: Stand �N SeamÆ

Color: Kynar Classic Green

C O N C E A L E D - F A S T E N E R P A N E L S

16

C O N C E A L E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AS E L E C T S E R I E S ® 1 2

• Classic concealed-fastener lush panel design

• Ideal for long spanning walls, equipment screens, fascias and/or soit applications

• Aesthetically pleasing for architectural, commercial and industrial applications

• 1 1/2" depth is stronger and spans greater distances than 1" panels

• Various stifening bead patterns can be mixed and

matched for multitudes of aesthetic designs

• Proile can be used with Select Series 612 panel variation for additional aesthetic designs

• Concealed fastened panel utilizing a screw lange requires no panel clips

• Panel ends can be swedged for end laps*

• Factory applied sealant is available

• Panels can be perforated upon special request

• .032" and .040" aluminum and 24, 22, and 20 gauge steel are available

1 1

/2"

12"

Air Iniltration

ASTM E283 0.10 @ 1.57 psf

ASTM E1680 0.25 @ 6.24 psf

Water Penetration

ASTM E331 no water @ 12 psf

Available Width

12"

Standard Lengths

18" to 40'–0" FOR WALLS ONLY; DO NOT USE ON ROOFS

12"

1 1

/2"

12"

1 1

/2"

SELECT SERIES 12-R1

SELECT SERIES 12W

SELECT SERIES 12-R0

1 1

/2"

12"

SELECT SERIES 12-R2* (recommended standard)

17

C O N C E A L E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AS E L E C T S E R I E S ® 6 1 2

• Classic six up six down wall panel design

• Ideal for long spanning walls, equipment screens and/or soit applications

• Aesthetically pleasing for architectural, commercial and industrial applications

• 1 1/2" depth is stronger and spans greater distances than 1" panel

• Proile can be used with Select Series 12 panel variation for additional aesthetic designs

• Concealed fastener panel utilizing a screw lange requires no panel clips

• Factory applied sealant is available

• Panel ends can be swedged for end laps*

• .032" and .040" aluminum and 24, 22 and 20 gauge steel are available

1 1

5/6

4"

12"

6"6 3/4" REF.

1 1

/2"

Available Width

12" with a 6" off-set

Standard Lengths

18" to 40'–0"

FOR WALLS ONLY; DO NOT USE ON ROOFS

1 1

/2"

6 3/4" REF. 6"

12"

SELECT SERIES 612-R1* (recommended standard)

SELECT SERIES 612

D É C O R - F L U S H ®

• Ideal for soits, fascias and vertical wall applications

• Concealed fasteners for maximum aesthetic value

• Factory applied sealant at side joint

• Stifening grooves available

• .032" aluminum and 24 gauge steel are available

12" COVERAGE

1"

13 9/16" OVERALL

Standard Lengths

6' to 25’ (longer lengths

available upon request)

18

C O N C E A L E D - F A S T E N E R P A N E L S

T E C H N I C A L D A T AP O S I - L O C K S O F F I T

• Interlocking design with concealed fasteners allows for fast and economical installation

• Aluminum is available vented with a 9.2% free open area

• .032" aluminum and 24 gauge steel are available

4 9/16"

14"

3/8"

Available Width

14"

Standard Lengths

6' to 25’ (longer lengths

available upon request) FOR SOFFITS ONLY; DO NOT USE ON ROOFS

19

EX

PO

SE

D-

FA

ST

EN

ER

P

AN

EL

S

20

Project: Fauner Family YMCA, Chicago, ILPanel: Deep Rib IV & Hefti-RibÆ

Color: Kynar Apothecary Blue & Custom Red & Yellow

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T AH E F T I - R I B ®

• 7.2" rib pitch allows best strength-to-weight ratio available

• Excellent for both wall and roof applications

• Diaphragm capacity per ICBO Evaluation Report

• Mitered corners are available

• May be used in vertical or horizontal orientation

• Available curved

• Class 4 impact rating

• Class A ire rating

• .032", .040" and .050" aluminum and 26, 24, 22, 20 and 18 gauge steel are available

36"

CL L

C

PAINTED SIDE7.2"

1 1

/2"

Wind Uplift

UL90 #244

Air Iniltration

ASTM E283 .00 @ 20 psf

Water Penetration

ASTM E331 no water @ 20 psf

Minimum Roof Slope

2:12

Available Width

36"

Standard Lengths

6' to 45'

21

H R - 2 8 8

• Lighter gauge commercial and industrial wall or long span rooing panel

• Ideal for Carports, Walkway Canopies and Eyebrow

Canopies

• Material: Silconized Modiied Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• 28.8" coverage based on a 43" coil feed

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

1 1

/2"28 4/5" COVERAGE

7.2"

Minimum Roof Slope

2:12

Available Width

28.8"

Standard Lengths

6' to 45'

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T AU L T R A R I B ®

• Original true 1 1/2" high multi-rib panel

• Purlin bearing leg ensures proper attachment and lap engagement

• Ideal for commercial and industrial applications

• Aluminum available on an inquiry basis

• May be used in vertical or horizontal orientation

• Class 4 impact rating

• Class A ire rating

• .032" aluminum or 26, 24 and 22 gauge steel are available

38" OVERALL

12"

1 1/2"

36" COVERAGE

Wind Uplift

UL90 #168

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 40'

4 " R I B

• An industry standard — ideal for heavy industrial and lagging applications

• Available in mill inish, alclad or painted

• 8" rib available on inquiry basis

• May be used in vertical or horizontal orientation

• Available in .032", .040" and .050" aluminum in various widths

• Available in 24 and 22 gauge steel in various widths

35 9/16"

32"

1"

Standard Available Width

32" (painted aluminum is 36"; unpainted aluminum is 44")

Standard Lengths

6' to 45'

22

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T AV - B E A M

• Excellent strength and spanning capability

• Diaphragm capacity per ICBO Evaluation Report

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available in .032", .040" and .050" aluminum in various widths

• Available in 24 and 22 gauge steel in various widths

32" COVERAGE

1 3/4"

33 7/8" OVERALL

Minimum Roof Slope

2:12

Standard Available Width

32" (painted aluminum is 32"; unpainted aluminum is 42 2/3")

Width Notes:

1. From 48.25” Coil, 38.25” Formed Width & 32” Coverage

2. From 44.375” Coil, 35” Formed Width & 32” Coverage

3. From 57” Coil, 44.875” Formed Width & 42.67” Coverage

Standard Lengths

6' to 45'

23

Project: Lynx Regional Center, Central Florida Regional Transportation Authority, Orlando, FLPanel: Deep Rib IVColor: Kynar Bright Silver on both sides

24

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T A1 / 2 " C O R R U G A T E D

• An economical and versatile wall or roof panel

• Can be perforated for acoustical applications

• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• Class 4 impact rating

• Class A ire rating

• .032", .040" and .050" aluminum are available in various widths

• 26, 24, 22, 20 and 18 gauge steel are available in various widths

OVERALL VARIES

COVERAGE VARIES

1/2"

2.667"

Minimum Roof Slope

2 1/2:12

Standard Lengths

6' to 45'

7 / 8 " C O R R U G A T E D

• Bolder look

• Great for exterior and interior uses

• Can be perforated for acoustical applications

• Standard 13.3% open area (1/8" diameter holes on .325" staggered centers)

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• .032", .040" and .050" aluminum are available in various widths

• 26, 24, 22, 20 and 18 gauge steel are available in various widths

PAINTED SIDE

7/8

"

32"

2.667"

Minimum Roof Slope

2 1/2:12

Standard Lengths

6' to 45'

25

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T AD E E P R I B I I

• Can be used for both wall and roof applications

• May be used in vertical or horizontal orientation

• Mitered corners are available

• .032", .040" and .050" aluminum are available in various widths

• 22, 20 and 18 gauge steel are available in various widths

2"

40"

44 1/2"

33 3/4" OVERALL

30" COVERAGE

2"

OVERLAP CORRUGATION

OVERLAP CORRUGATION

Minimum Roof Slope (when inverted as roof )

1:12

Available Widths

30" and 40"

Standard Lengths

6' to 45'

D E E P R I B I V

• A bold rib design, ideal for horizontal and vertical applications

• 4" deep ribs provide excellent strength and spanning capacity

• Can be used for both wall and roofs (inverted for roof )

• Excellent for applications with large spans between

structural framing members

• May be used in vertical or horizontal orientation

• Mitered corners are available

• Available curved

• .032", .040" and .050" aluminum and 22, 20 and 18 gauge steel are available

12"

24" COVERAGE

25 1/4" OVERALL

4"

12"

25 1/4" OVERALL

24" COVERAGE

4"

Minimum Roof Slope

1:12

Available Width

24"

Standard Lengths

6' to 45'

Siding

Roofing

26

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T A

R - P A N E L

• Economic commercial and industrial wall panel

• Ideal for metal buildings, light commercial structures

and modular buildings

• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• Full 36" net coverage based on a 41.5625" coil feed

• 1 1/4" high major ribs on 12" center with intermediate ribs for added strength and durability

• May be used in vertical or horizontal orientation

• Panels can be reverse run for wall applications ofering

alternate visual aesthetics

• 26 gauge steel; heavier gauges available upon request

1 1

/4"

PAINTED SIDE

36"

12" 12" 12"

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 45'

27

M I G H T I - R I B ®

• Excellent commercial and industrial roof, wall or fascia requiring economic covering

• Purlin bearing leg ensures proper attachment and lap engagement

• Diaphragm capacity per ICBO Evaluation Report

• UL90 rating when attached to steel purlins

• Available unpainted or inished with high-performance

Enduracote® paint system in 26 gauge and PVDF in heavier gauges

• Aluminum available on an inquiry basis

• May be used in vertical or horizontal orientation

• Class 4 impact rating

• Class A ire rating

• 26 and 24 gauge steel; heavier gauges available upon request.

PAINTED SIDE

36"

1 1

/4"

12"12"12"

Wind Uplift

UL90 #169

Factory Mutual FM Class I-90

Minimum Roof Slope

1:12

Available Width

36"

Standard Lengths

6' to 45'

29

Project: Target Store, Albany, CAPanel: Deep Rib IV & Hefti-RibÆ

Color: Pewter & Custom Kynar Red

E X P O S E D - FA S T E N E R PA N E L S

T E C H N I C A L D A T AU - P A N E L

• Economic commercial and industrial wall panel

• Ideal for metal buildings, light commercial structures, modular buildings and mini storage interior partition walls

• Material: Polyester painted GALVALUME® AZ-50 (Aluminum-Zinc Coated Steel) and Mill Finished GALVALUME® Plus AZ-55

• 36" coverage based on a 41.5625" coil feed

• 3/4" high major ribs at 6" centers

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

PAINTED SIDE1

3/1

6"

36"

Minimum Roof Slope

2 1/2:12

Available Width

36"

Standard Lengths

3' to 45'

P B U P A N E L

• PBU is economical commercial and industrial roof and wall panel

• Purlin bearing leg ensures proper attachment and lap engagement

• Ideal for Mini Storage partition wall panels and back

side parapet wall covering

• Panel can be reverse run for wall applications ofering

alternate visual aesthetics

• May be used in vertical or horizontal orientation

• 26 gauge steel is available

PAINTED SIDE

36"

3/4

"

Wind Uplift

UL90 #39, 79

Minimum Roof Slope

2 1/2:12

Available Width

36"

Standard Lengths

3' to 45'

28

8

Project: Prescott Valley Mall, Prescott, AZPanel: Thin SeamColor: Custom Kynar Granite Green

Panel: Grand Curve�

Color: Kynar Burgundy & Old Town Gray

L I N E R PA N E L & S P E C I A LT Y P R O D U C T S

L P - 1 5 L I N E R P A N E L

24"

1 7/16"

Available Width

24"

Standard Lengths

6' to 45'

WALL AND INTERIOR CEILING ONLY; DO NOT USE AS ROOF PANEL

1 1/2"

3/8" 3"

SUBGIRT

T E C H N I C A L D A T A

A R C H I T E C T U R A L S P E C I A LT Y S H E E T M E TA L B Y C O P P E R C R A F T

Look to CopperCraft by Fabral for high quality

architectural sheet metal products to complete your

projects. Experienced sheet metal craftsmen will

fabricate products from your ideas and drawings

or from our standard selection of products including

dormers, inials, spires and more.

CopperCraft combines old world craftsmanship

with modern day technology and equipment to

provide high quality yet afordable architectural

sheet metal products. To learn more or review the

complete CopperCraft product ofering, visit

www.coppercraft.com.

31

• Perfect for ield-assembled projects requiring insulated walls and roofs

• Panel legs allow for easy attachment of subgirts

• Factory applied sealant in overlapping rib to ensure a weather-tight assembly

• Available perforated for acoustical applications

• Thermal and acoustical test reports available

• Consult Fabral for the availability of LP-25 (2 1/2" deep liner panel) and LP-12, 12" wide

Note: For aluminum liner applications, subgirts must be through-fastened to structural girts.

ST

RU

CT

UR

AL

M

EM

BE

RS

&

GE

NE

RA

L

IN

FO

RM

AT

IO

N

32

Project: Foundry Square Ofice Building, San Francisco, CAPanel: T-RibÆ

Color: Custom Kynar Silver Mica

S T R U C T U R A L M E M B E R S

S E C O N D A R Y S T R U C T U R A L F R A M I N G

Fabral manufactures a full line of light gauge cold-formed

steel sections for use in secondary framing applications.

Steel sections provide economic secondary structural

framing for pre-engineered metal buildings, carports,

canopies, walkway covers, parking covers and eyebrow

canopies. They are also used as the primary structural

framing of single story mini-storage structures.

The sections are available in 16 Gauge (.060")*, 14

Gauge (.077")* and 12 Gauge (.099")* thicknesses.

Zee, Cee and Channel standard sizes are 4" to 12"

depths (even 2" increments). Angle standard sizes

are 2"x 2", 2"x 4" and 3"x 3". Eave Strut standard sizes

are 8"x 5"x 2 1/2" and 8"x 5"x 5". These sections are

available with either a red-oxide prime or hot-dipped

galvanized protective coating. Red-oxide members are

manufactured from ASTM A570 Grade 55 steel (55 KSI

minimum yield strength). Galvanized members are

manufactured from ASTM A653 G-90 Galvanized

Grade 55 steel (55 KSI minimum yield strength).

Fabral’s manufacturing capabilities produce Zee purlins

to symmetrical or asymmetrical designs. Eave Struts

can be produced for high and low eaves and are available

in single and double slope coniguration. Standard

purlin punching patterns include A, B, C, G and H

web punching which allows for simple span, short lap

and long lap conditions. Custom punch patterns and

custom shapes are available; please consult your Fabral

representative for details.

Light gauge cold-formed structural steel sections are

produced in Grapevine, TX and Salem, OR.

*Thicknesses indicated represent design thicknesses. Minimum deliverable bare steel thickness equals 0.95 x design thickness in accordance with Section A3.4 of the AISI Speciications for minimum steel thickness in inches.

Structural Member Beneits:

• Made to order

• 55 KSI Yield Strength

• 70 KSI Tensile Strength

• Prime Red-Oxide (produced only in Grapevine, TX) or Galvanized G-90

• ASTM A570 and ASTM A653 Qualiied

• Full range of sizes and shapes

• Roll formed lengths up to 45' in Salem, OR and 47' in Grapevine, TX

• Press break lengths up to 32' in Salem, OR and 38'–6" in Grapevine, TX

• Wide variety of punch patterns and hole sizes available

• Symmetrical Cee Sections

• Asymmetrical Zee Sections — nests and allow ease of section overlaps

• Complete inventory of accessory parts

Angles Eave Strut

Cee Channel

Zee

33

G E N E R A L I N F O R M A T I O N

F I N I S H E S A N D S U B S T R A T E S

• Fabral metal wall and roof systems feature Flurobond coatings that utilize 70% Kynar 500® or Hylar 5000® polyvinylidene luoride (PVDF) resins to ensure long-term color retention and performance

• In addition to PVDF-based inishes, Fabral can also provide other inishes for speciic applications

• GALVALUME®, Grade 50, AZ50 or AZ55 Aluminum-Zinc alloy coating conforming to ASTM A792

– 24, 22 and 18 gauge standard for all proiles

– 20 gauge available for most proiles — please inquire

– Acrylic coating standard for all unpainted applications

• Aluminum

– .032" Aluminum, Alloy 3105 H14 standard for standing-seam panels

– .040" Aluminum available for select standing seam proiles

– .032" and .040" Aluminum, Alloy 3105 or 3004 H36 or equal standard for exposed/concealed fastener panels — .050" available for select proiles

– Alclad (Alloy 3004 with 7072 cladding) Aluminum available for select proiles

• Galvanized Steel, G-90 or Grade 50 conforming to ASTM A653

– 24, 22 and 18 gauge are standard for most proiles— for 20 gauge please inquire

• Stainless Steel, Copper, Zinc — please inquire for availability

• Consult for the availability of fabricated lashings and trim, mitered corners, fasteners, roof underlayment, sealant, touch-up paint, etc.

• Oil canning can be caused by many factors that are out of Fabral’s control and is not cause for rejection

Field Assembled Wall Details

W A R R A N T I E S

• Fabral panels feature a 20-year paint-inish warranty

• A wide selection of Fabral weathertightness warranties are available for up to 20 years on most standing-seam panels — providing you with the peace of mind and conidence of knowing you have long lasting application protection

• Corrosion warranties are available for our products that

utilize GALVALUME® or aluminum as a substrate material

• You may request a copy of any of our warranties for specific details

ZBAR OR

HAT BAR

INSULATION

HEFTI-RIB (OR ANY PRO FILE)

CORR UGATED

LINER

SUBGIRT

LP-15CFP-6

(OR ANY PROFILE)

INSULATION

Field Assembled System — Corrugated Liner

Field Assembled System — Flat Liner

Kynar 500® is a registered trademark of Atoina Chemicals.Hylar 5000® is a registered trademark of Solray Solexis.GALVALUME® is a registered trademark of BIEC International, Inc.

34

G E N E R A L I N F O R M A T I O N

T E S T R E P O R T S

ASTM E1592 UPLIFT

This is the latest metal rooing uplift test. This test simulates actual ield conditions because of the large

chamber. The test chamber is usually at least ive panels wide by length to test multiple purlin spacings

(usually 25'). Air pressure is applied, delections are recorded and panels are closely examined after each test

cycle. Failure loads are recorded so the test results can be used for design purposes unlike the UL uplift test

results. This is the standard test required for standing-seam panels on Army Corps. of Engineers’ projects.

FACTORY MUTUAL

This approval includes wind uplift testing using ASTM E1592. Class I-90 must resist 90 psf uplift load.

MIAMI DADE APPROVAL

This approval requires wind uplift testing, wind driven rain testing, among others to meet the high wind

hurricane zones in Florida.

UL90 UPLIFT RATING

This wind uplift resistance test (UL580) has become an industry standard. Test panel specimens are placed

on a 10' x 10' test chamber and fastened to the tested substrate. The test involves severe load cycling as well

as testing for a sustained period of ive minutes at a maximum uplift pressure of 105 psf for a UL90 rating.

UL60 and UL30 ratings are similar to UL90 ratings except that the maximum uplift pressure is 75 psf and 45

psf respectively. Because the specimens are not tested to failure and the test assembly is not similar to an

actual roof assembly, test ratings and assemblies should not automatically be used for design purposes.

AIR INFILTRATION

ASTM E283 is a static air iniltration test using an air-tight test chamber assembly in the form of a large box.

The panel test specimens constitute one of the sides of the box. Air is forced into or exhausted from the test

chamber, producing a pressure diferential across the specimen. The amount of air passing through the test

panels is measured in cfm. ASTM E1680, a new standard, is the air iniltration and exiltration test standard

designed speciically for metal roof panels.

WATER PENETRATION

ASTM E331 is a static water penetration test. The test chamber is identical to the air iniltration test.

Diferential pressures are applied for 15 minutes while spraying water uniformly over the exterior surface

of the panel test specimens. The passing requirement for ASTM E331 is that there shall be no evidence of

any “uncontrolled leakage” during the test. ASTM E1646, a new standard, is the water penetration test

standard designed speciically for metal roof panels.

FIREWALL PANELS

UL rated one, two and three hour ire-resistant panels are available utilizing Fabral steel (and aluminum in

some cases) liner panels and exterior proiles. Field assembled layers of gypsum wall board (5/8" thick per

layer) and glass iber insulations are placed between the liner and exterior panels. Contact Fabral for speciic

information on these irewalls.

Consult Fabral for other test data availability. 35

CORPORATE HEADQUARTERS

3449 Hempland Rd.

Lancaster, PA 17604

800-477-2741

800-283-4289 Fax

FABRAL ARCHITECTURAL SYSTEMS

308 Alabama Blvd.

Jackson, GA 30233

800-884-4484

800-765-4484 Fax

404 E. Dallas Rd.

Grapevine, TX 76051

800-477-9066

817-488-0446 Fax

4570 Ridge Dr., N.E.

Salem, OR 97303

800-477-8028

503-393-5813 Fax

COPPERCRAFT DIVISION

4995 Keller Haslet Rd.

Keller, TX 76248

800-486-2723

817-490-9961 Fax

www.coppercraft.com

ADDITIONAL MANUFACTURING

LOCATIONS

• Cedar City, UT

• Columbia, SC

• Gridley, IL

• Idabel, OK

• Lancaster, PA

• Marshield, WI

• Mooresburg, TN

• Mt. Vernon, OH

• Saint Joseph, MN

• Spokane, WA

• Tifton, GA

www.fabral.comI/A-198-32-14901/08 10K

For light gauge agricultural and residential products,

contact our Woodframe division in Lancaster, PA.