Example Description, V01

PS563-WATER Library PackageLogData_AC500_V23 Data Logging LibraryApplication Examples

Page 2: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 1 AC500 / Issue: 08.2015

Content

1. INTRODUCTION TO DOCUMENT ............................................................................. 21.1 Scope of the document ................................................................................................... 21.2 Overview of the Content ................................................................................................. 21.3 Compatibility ................................................................................................................... 21.4 Safety Instructions .......................................................................................................... 2

2. Logger Overview ............................................................................................................ 32.1 Operating Modes of the Logger ......................................................................................... 5

2.1.1 Mode 0/1: Buffer and disposal in chronologic order ....................................................... 5

2.1.2 Mode 2: Buffer and disposal via FTP ............................................................................ 6

2.1.3 Mode 3: Events Recorder.............................................................................................. 6

3. Generic Example program ............................................................................................ 83.1 Preparation ......................................................................................................................... 83.2 Use Mode 0/1 Buffer and disposal in chronologic order ............................................... 103.2 Use mode 2: Buffer and disposal via FTP ....................................................................... 153.3 Use mode 3: Event recorder ............................................................................................ 17

4. IEC60870 Example program ........................................................................................ 194.1 Preparation ....................................................................................................................... 194.2 Use Mode 0/1: Buffer and disposal in chronologic order .............................................. 23

5. REVISION HISTORY ................................................................................................ 25

Page 3: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 2 AC500 / Issue: 08.2015

1. INTRODUCTION TO DOCUMENT

1.1 Scope of the documentThis document is intended for explaining the first use of the LogData AC500 library, with the providedexample projects, to directly log data of remote communication connections of the AC500 or as standalonedata logger.

1.2 Overview of the ContentThere are two example projects provided for the two different use cases of the logger.In chapter 3 the Example for logging of generic protocols is described, while the logging for IEC 60870protocol is described in chapter 4.The necessary preparation of the AC500 is explained at the beginning of each of these example chapters.In the ready to run application programs Ethernet communication is assumed to transfer and receive databetween AC500 acting as a substation (logging data in case of interruptions in communication) and a controlstation (receiving then e.g. logged historical data after a communication is there again after an outage).

1.3 CompatibilityThe example programs explained in this document has been used with the below engineering systemversions. It should also work with other versions; nevertheless some small adaptations may be necessary,for future versions.· AC500 Control Builder Plus CBP V2.3., as delivered with Automation Builder V 1.0 Suite of Engineering

programs.

1.4 Safety InstructionsThe user must follow all applicable safety instructions and the guidelines mentioned in the user documents ofthe ABB products used in the example program· Read the complete safety instructions for the AC500 before installation and commissioning.· Read all safety instructions of your control station system manuals..

Page 4: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 3 AC500 / Issue: 08.2015

2. Logger Overview

The AC500 Datalogging Function Block Library contains five Function Blocks for the purpose of advancedtime-stamped data logging for different use cases. In typical use cases the AC500 application programgenerates data which are normally transmitted to a telecontrol system for storage and further processing ordisplaying to the end user. Typically, these may be remote applications like water pumping stations or solarpower plants where the connection between the remote station (AC500) and a central SCADA/telecontrolstation is not always stable or only sporadically connected. Sporadically connected can be by intention e.g.to save communication costs or open ports/connections to be handled by a control station. Then theDatalogging Function Blocks can store data in case of a broken or intentionally interrupted connectionbetween AC500 and the telecontrol system.

1 AC500 application2 telecontrol

Fig. 1: Overview

Alternatively· The Datalogging Library can be used as an event recorder. In this special mode data is continuously

recorded in a ring buffer which can be read out after a certain event x (e.g. outage) in order to analyzethe values especially before but also after the event x.

· Data can be logged only and on command transferred to the ftp area to be analyzed offline or taken outvia the SD card.

The following figure 2 gives an overview of the described interaction of the Datalogging Function Blocks.There is always an input Function Block needed which transfers the input data into data sets with timestampfor use by the Datalogger. An output Function Block receives the current or retrieved data from theDatalogger in case of communication or further processing. The input Function Blocks "LOG_xxx_INPUT",the Function Block "LOG_HANDLING" and the output Function Blocks "LOG_xxx_OUTPUT" communicatevia SRAM FIFOin and FIFOout areas in the memory. This SRAM FIFOs are intermediate buffers and help indecoupling time wise and speeding up the necessary write/read operations on the logging file structuressignificantly. These read/write operations on the files are done in blocks of datasets, enabling a comparablyfast interaction with the otherwise slow file system.

Page 5: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 4 AC500 / Issue: 08.2015

Fig. 2: Overview Function Blocks

Each Datalogging application requires the main Function Block LOG_HANDLING , one of the input FunctionBlocks to provide data to be logged and one output Function Block to retrieve the data.As input and output Function Blocks two different types exist:· For logging data of an interrupted IEC60870 communication, the Function Blocks

LOG_IEC60870_INPUT and LOG_IEC60870_OUTPUT are provided. The IEC60870 DataloggingFunction Blocks support the IEC data types and work internally with the standard AC500 IEC60870Library. The IEC Datalogger output Function Block does not need special handling or control/inputs.

· For other types of general data LOG_GENERIC_INPUT and LOG_GENERIC_OUTPUT are provided.The generic Datalogging Function Blocks support an even larger variety of data types. The genericoutput Function Block needs to be hand-shaked with for each data set, in order to retrieve the data fromthe Datalogging files. Therefore the generic Function Blocks can also be used to integrate the datalogging into any other protocol, e.g. Modbus.

The Function Block LOG_HANDLING ensures that also several consecutive and fast interruptions can behandled without losing data. While the log file is replayed, arriving new data is stored in the SRAM FIFOinand added to the Datalogging files (File FIFO) if the SRAM FIFOin becomes full - during that short time thelog file replay is paused. Nevertheless any data send to a control station via a communication is always withthe oldest data first (FIFIO = “First In First Out”).As it takes up to 30 seconds before a communication break is detected (e.g. with TCP/IP protocols by theAC500 hardware/firmware), the data rate at which data should be logged in case of a communication breakhas to be calculated and limited.As an improvement a ping mechanism can be implemented in the Substation. This was done in the exampleprogram for the IEC logger. With this ping the interruption is already detected after 1-2 seconds (can beconfigured in the example program).As the SRAM FIFOin has to store data during this time, its size limits the data rate. The SRAM FIFO size is160 datasets. This means the data rate should be lower than approximately max. datarate = 160datasets/2seconds => <80 datasets/secondThe data rates for storing only without this detection can be much higher and depends on the CPU andmemory type chosen; see “Overview of technical details” in the online help. The data is always logged indirectly readable csv format, see “CSV-File Formats” in the online help. Depending on the input FunctionBlock and data type, the log file contains only one or up to 32 data variables per time-stamped data set, see“CSV-File Formats” in the online help. The Datalogging files can be configured (up to 65k datasets per file,up to 999 consecutive log files, name format).

Page 6: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 5 AC500 / Issue: 08.2015

2.1 Operating Modes of the LoggerThis chapter describes the different operating modes of the Datalogging and their behavior:· Mode 0/1: Buffer and disposal in chronologic order

o Mode 0: Limited storage (keeps oldest, but stops if full)o Mode 1: Endless (ring buffer) operation modes (deletes oldest)

· Mode 2: Buffer and disposal via FTP, Log file(s) copied to ftp server area for further use· Mode 3: Events Recorder, logs data before and after an event.

2.1.1 Mode 0/1: Buffer and disposal in chronologic order

Fig. 3: Overview Mode 0/1

Mode 0/1 is for buffering the values from the AC500 application in case of a broken or intentionallyinterrupted connection between AC500 and telecontrol. In the normal state 1 the values are directly sentfrom the FIFOin (input values from application) to FIFOout (telecontrol connection). As soon as theconnection is interrupted, the Datalogger changes to working state 2. The values are sent to the File FIFOinstead. When the File FIFO is full, the Datalogging is stopped (Mode 0) or the oldest data will be overwritten(Mode 1 = ringbuffer). When the connection is established again and the RELEASE_HISTORY pin istriggered, the Datalogger changes to working state 3. It cares for disposal of the values in chronologicalorder. The buffered values are written to FIFOout (working state 3a). This may take some time during whichnew values are coming from the application and stored into FIFOin. Before the FIFOin overflows theDatalogger switches to working state 3b and buffers the new values. After that it can continue with workingstate 3a. Only if the File FIFO is empty (all files deleted) the Datalogger changes back to normal state 1.The advantage of Mode 0/1 is that all values (directly and buffered) are sent to telecontrol in strictlychronological order which is expected by most control stations (SCADA systems/historians).

As it takes up to 30 seconds before a communication break is detected (e.g. with TCP/IP protocols bythe AC500 hardware/firmware), the data rate at which data should be logged in case of acommunication break has to be calculated and limited.

Page 7: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 6 AC500 / Issue: 08.2015

2.1.2 Mode 2: Buffer and disposal via FTP

Fig. 4: Overview Mode 2

Mode 2 is also used for buffering the values from AC500 application in case of a broken connection betweenAC500 and telecontrol. State 1 and state 2 are similar to Mode 0/1. The difference is the disposal. When theconnection is established again the Datalogger changes directly back to state 1 and the input values inFIFOin are directly sent to FIFOout (telecontrol connection). The buffered values in File FIFO are internallymoved from disk 1 to disk 2 which can then be accessed or used by FTP (client or server). This move actioncan also be triggered by the command MOVE_FILES, or when file 1 is full. The advantage of Mode 2 is theimmediate availability of the latest and all current values after an outage.

2.1.3 Mode 3: Events Recorder

Fig. 5: Overview Mode 3

Mode 3 is used to record data values around an event, before and after the event x, e.g. outage of a part ofthe plant. The values are continuously recorded into the File FIFO file system independent of the connectionstatus to telecontrol. If the File FIFO is full the oldest values are overwritten (ring buffer). Thus the File FIFOalways contains the values from the past period n, which is depending on the amount of values per secondand on the size of the File FIFO. When a certain event x occurs, the command MOVE_FILES can be givendirectly or after the period m. With the command MOVE_FILES the values in File FIFO are internally movedfrom disk1 to disk 2 and can be read out by an FTP action (client or server) when required.

Page 8: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 7 AC500 / Issue: 08.2015

Fig. 6: The buffered values represent the time before the event (n-m) and after the event (m).

The advantage of mode 3 is that the values from the time period before the event (n-m) and after the event(m) are recorded and can help to reconstruct the cause and effect of the event.

Page 9: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 8 AC500 / Issue: 08.2015

3. Generic Example program

This chapter describes how to use the Generic Logger example program. The following components wereused for the example::· One AC500 CPU (PM573 or higher), representing the substation, which sends the Generic data and / or

logs them according to the selected mode.o IP address, e.g. 192.168.0.22o SD card must be inserted. Alternative: Use a PM592 with internal flash disk

· ABB Automation Builder, Version 1.1, running on a PC which is connected to the AC500 via Ethernet· Library: LogData_AC500_V23.lib (Library Version 1.1.0)· Example project: “Example_Generic_LogData_V23.project”

3.1 PreparationThe following steps have to be executed1. Copy the library (LogData_AC500_V23.lib) into the common library folder:

C:\Program Files (x86)\Common Files\CAA-Targets\ABB_AC500\AC500_V12\library\PS563-WATER\library orC:\Program Files \Common Files\CAA-Targets\ABB_AC500\AC500_V12\library\PS563-WATER\library

2. Open the example project (example_Generic_LogData_V23.project) with AB3. The example is based on one AC500 CPU, type PM592-ETH. For use with other CPU types a target

change has to be performed:

Page 10: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 9 AC500 / Issue: 08.2015

4. Configure in Automation builder

a. Activate FTP server, optionally assign passwords

5. Download to AC500a. DoubleClick example_LOG_Generic_Substation_V23_062 in order to open program in

CoDeSysb. Project – Clean All, Buildc. Online - Set communication parameter to the CPU

d. Online – Login, Create boot project, Run

Page 11: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 10 AC500 / Issue: 08.2015

3.2 Use Mode 0/1 Buffer and disposal in chronologic order1. Configure test program for Mode 0/1

a. Open Visualization: LogData_GENERIC_total2:

àAll yellow fields can be configured or activated

b. Control:- Mode 0 (Buffer and disposal in chronologic order, pure buffer)- Max No of files. 10 (Maximum: 999)- Max No of DS/File: 100 (Maximum: 65535)- Drive 1 = SD (if not PM592 with internal flash disk)

c. Input values (These test values are created by the example program)- Activate all 7 data types (BOOL, BYTE, REAL, …)- Cyclically, 200 (Sending 7 datasets every second = 200 * 10 ms cycle time)

Page 12: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 11 AC500 / Issue: 08.2015

d. Result:

àData is transferred directly to the control station (following the green arrows), no buffering. Thisis the normal state = State 1 in Figure 3.

2. Mode 0 with breaka. Start with normal state = State 1b. Simulate connection break by pressing the Break button between RAM FIFOOut and Control

Station

Page 13: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 12 AC500 / Issue: 08.2015

c. Result

àControl station is disconnected (color in the arrow turns to orange). Logger switches to State 2:Data is written into the File FIFO instead, starting with file1.csv.

d. When a file is full, the next file is written:

Page 14: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 13 AC500 / Issue: 08.2015

e. The files on the SD card can be verified by connecting the AC500 with an FTP client (e.g.FileZilla):

f. Release button “Break”g. Press button “Release History” (Signal from the Control station that history data is released)h. Result: State 3

à Data is read from file buffer (File FIFO) and sent via RAMFIFOout to the Control station (State3a). In the meantime new data is buffered in RAM FIFOin. Before this buffer overflows the stateis shortly switched to 3b in order to save the new data in the File FIFO:

Page 15: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 14 AC500 / Issue: 08.2015

i. When the File FIFO is empty the logger switches to the normal State 1:

àThe files on the SD card are deleted accordingly

3. Mode 0 with buffer overflowa. Reset all values by pressing button “Reset”b. Press button “Break”c. Wait until maximum number of files in File FIFO is reached:

à The buffering stops and the FIFOin runs full.

Page 16: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 15 AC500 / Issue: 08.2015

d. The FIFOin gets and overflow after some time and newest data get lost:

à Inorder to avoid losing the newest data mode 1 can be used instead

4. Mode 1 without buffer overflow (similar to mode 0, but Ring buffer)a. Enter Mode 1b. Resetc. Break connectiond. Wait until maximum number of files in File FIFO is reached

à Incomparison to Mode 0 the buffering continues by overwriting the oldest files (Ring-Buffer mode)

3.2 Use mode 2: Buffer and disposal via FTPa. Enter mode 2

Page 17: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 16 AC500 / Issue: 08.2015

b. Resetc. Set Drive2 = SD (if not PM592 with internal flash disk)d. Break connectione. Result: file1 is filled

Page 18: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 17 AC500 / Issue: 08.2015

f. When file1 is full it is automatically copied to the FTP folder with a unique name consisting of thedate and time. These files can be retreived for further processing using an FTP client:

g. Other triggers for copying the file can be: Button „Move files“ or release “Break” button

3.3 Use mode 3: Event recordera. Enter mode 3b. Resetc. Data is always and continously buffered, independent of the Break button. No data is transferred

to the control station:

d. When the maximum number of files is reached the first files are overwritten (ring buffer mode)

Page 19: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 18 AC500 / Issue: 08.2015

e. In case of an event (e.g. fault in the plant) the command “MOVE_FILES” should be initiated aftera certain time period m. In this example it can be triggered by the button “Move files”.With this command the complete buffer is copied to the FTP folder:

f. These files in the FTP folder can be retreived for further diagnostics using the FTP client. Theyrepresent a certain time period before the event (n-m) and the period after the event (m), seealso online documentation:

Page 20: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 19 AC500 / Issue: 08.2015

4. IEC60870 Example program

This chapter describes how to use the IEC 60870 Logger example program. The following components wereused for the example:· Two AC500 CPUs (PM573 or higher), interconnected via Ethernet using an Ethernet switch

1. CPU1: Control station: Receiving the IEC 60870 data from the substationIP address, e.g. 192.168.0.21

2. CPU2: Substation: Sending the IEC 60870 data and logging it in case of connection interrupt,IP address, e.g. 192.168.0.22SD card must be inserted if not PM592 with internal flash disk

· ABB Automation Builder, Version 1.1, running on a PC which is connected to the AC500 pair via theswitch

· Library: LogData_AC500_V23.lib (Library Version 1.1.0)· Example project: example_IEC60870_LogData_V23.project

4.1 PreparationThe following steps have to be executed1. Load the library (LogData_AC500_V23.lib) into the common library folder:

C:\Program Files (x86)\Common Files\CAA-Targets\ABB_AC500\AC500_V12\PS563-WATER\library orC:\Program Files\Common Files\CAA-Targets\ABB_AC500\AC500_V12\PS563-WATER\library

2. Open the example project (example_IEC60870_LogData_V23.project) with AB3. The example is based on two AC500 CPUs, type PM592-ETH. For use with other CPU types a target

change has to be performed:

Page 21: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 20 AC500 / Issue: 08.2015

4. Configure the control station (IP Controlstation: 192.168.0.54):a. Activate SNTP-Client and Connection to Substation

b. Enter IP address of the Substation (e.g. 192.16.5.55)

5. Download to the control station (CPU1)a. DoubleClick on example_LOG_IEC60870_Controlstation_V23 in order to open program in

CoDeSysb. Project – Clean All, Build

Page 22: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 21 AC500 / Issue: 08.2015

c. Online - Set communication parameter to CPU1:

d. Online – Login, Create boot project, Rune. Later PLC_PRG can be used for observing the received data:

Page 23: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 22 AC500 / Issue: 08.2015

6. Configure substation (IP Substation: 192.168.0.55)a. Activate FTP server, optionally assign passwords

7. Download to the substation (CPU2)a. DoubleClick example_LOG_IEC60870_Substation_V23_062 in order to open program in

CoDeSysb. Enter the correct IP address of the control station for the PING mechanism:

c. Project – Clean All, Build

Page 24: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 23 AC500 / Issue: 08.2015

d. Online - Set communication parameter to CPU2

e. Online – Login, Create boot project, Run

4.2 Use Mode 0/1: Buffer and disposal in chronologic order

1. Configure test program for Mode 0/1a. Open Visualization: LogData_IEC60870_total2:

à All yellow fields can be configured or activatedb. Control:

- Mode 0 (Buffer and disposal in chronologic order, pure buffer)- Max No of files. 10 (Maximum: 999)- Max No of DS/File: 100 (Maximum: 65535)- Drive 1 = SD (if not PM592 with internal flash disk)

c. Input values (Test values created by the example program)- Activate all 7 data types (SP1, IT1, ….)- Cyclically, 200 (Sending 7 datasets every second = 200 * 10 ms cycle time)

d. Result:

à Datais transferred directly to the control station (following the green arrows), no buffering. This stateis called State 1 in Figure 3.

Page 25: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 24 AC500 / Issue: 08.2015

2. Mode 0 with real connection breaka. Starting point: State 1b. Disconnect physical Ethernet cable from CPU1 (Control station)c. It takes around 1 second until the diconnection is recognized. In the meantime the data is

buffered in FIFOin. Afterwards the FIFO buffer starts buffering (State 2):

d. Plug Ethernet cable back into CPU1e. Release historyf. Result like above: State 3 (Reading data from File FIFO) and State 1 (when File FIFO is empty)

NoteModes 1, 2 and 3 work as described in the previous chapter (Generic).

Page 26: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

LogData - Water LibraryIntroduction and Examples Description 25 AC500 / Issue: 08.2015

5. REVISION HISTORY

Rev. ind. Page (P)Chapt. (C)

Description DateDept./Init

V01 No changes, only draft deleted 2013-10-23 / ACDTV11 All Screenshots updated (Automation Builder and new

Visu), …2015-08-10 / ACM2

Page 27: Example Description, V01 PS563-WATER Library Package ...docshare04.docshare.tips/files/30693/306937797.pdf · In chapter 3 the Example for logging of generic protocols is described,

abb ABB Automation Products GmbHWallstadter Str. 5968526 Ladenburg, GermanyPhone: +49 62 21 701 1444Fax : +49 62 21 701 1382E-Mail: [email protected]

www.abb.com/plc

Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreedparticulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of itscontents – in whole or in parts – is forbidden without prior written consent of ABB AG.© Copyright 2012 ABB , All rights reserved