Ethernet/IPFieldbus Interface Card

Customer Product ManualPart 1054600_06

Issued 08/15

NORDSON CORPORATION DULUTH, GEORGIA USAwww.nordson.com

This document contains important safety informationBe sure to read and follow all safety information in thisdocument and any other related documentation.

Page 2: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Part 1054600_06 E 2015 Nordson CorporationAll rights reserved

Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General informationabout Nordson can be found on the Internet using the following address: http://www.nordson.com.

Address all correspondence to:

Nordson CorporationAttn: Customer Service11475 Lakefield DriveDuluth, GA 30097

Notice

This is a Nordson Corporation publication which is protected by copyright. Original copyright date 2004.No part of this document may be photocopied, reproduced, or translated to another language without the prior writtenconsent of Nordson Corporation. The information contained in this publication is subject to change without notice.

Trademarks

AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Baitgun, Blue Box, Bowtie, Build-A-Part, CanWorks, Century, CF, CleanSleeve,CleanSpray, ColorMax, Color-on-Demand, Control Coat, Coolwave, Cross-Cut, cScan+, Dage, Dispensejet, DispenseMate, DuraBlue, DuraDrum, Durafiber,

DuraPail, Dura-Screen, Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo-Coat, e.DOT, EFD, Emerald, Encore, ESP, e stylized, ETI-stylized,Excel 2000, Fibrijet, Fillmaster, FlexiCoat, Flex-O-Coat, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Fulfill, GreenUV, HDLV, Heli-flow, Horizon, Hot Shot,iControl, iDry, iFlow, Isocoil, Isocore, Iso-Flo, iTRAX, Kinetix, LEAN CELL, Little Squirt, LogiComm, Magnastatic, March, Maverick, MEG, Meltex, Microcoat,

Micromark, Micromedics, MicroSet, Millennium, Mini Squirt, Mountaingate, Nordson, Optimum, Package of Values, Pattern View, PermaFlo, PicoDot,Porous Coat, PowderGrid, Powderware, Precisecoat, PRIMARC, Printplus, Prism, ProBlue, Prodigy, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, RBX, Rhino,Saturn, Saturn with rings, Scoreguard, Seal Sentry, Select Charge, Select Coat, Select Cure, Signature, Slautterback, Smart-Coat, Solder Plus, Spectrum,Speed-Coat, SureBead, Sure Coat, Sure-Max, Sure Wrap, Tracking Plus, TRAK, Trends, Tribomatic, TrueBlue, TrueCoat, Tubesetter, Ultra, UpTime,

u-TAH, Value Plastics, Vantage, VersaBlue, Versa-Coat, VersaDrum, VersaPail, Versa-Screen, Versa-Spray, VP Quick Fit,Watermark, and When you expect more. are registered trademarks of Nordson Corporation.

Accubar, Active Nozzle, Advanced Plasma Systems, AeroDeck, AeroWash, AltaBlue, AltaSlot, Alta Spray, Artiste, ATS, Auto-Flo, AutoScan, Axiom,Best Choice, Blue Series, Bravura, CanPro, Champion, Check Mate, ClassicBlue, Classic IX, Clean Coat, Cobalt, Controlled Fiberization, Control Weave,

ContourCoat, CPX, cSelect, Cyclo-Kinetic, DispensLink, Dry Cure, DuraBraid, DuraCoat, DuraPUR, Easy Clean, EasyOn, EasyPW, Eclipse, e.dot+,E-Nordson, Equalizer, EquiBead, FillEasy, Fill Sentry, Flow Coat, Fluxplus, Get Green With Blue, G-Net, G-Site, IntelliJet, iON, Iso-Flex, iTrend,

Lacquer Cure, Maxima, Mesa, MicroFin, MicroMax, Mikros, MiniBlue, MiniEdge, Minimeter, Multifill, MultiScan, Myritex, Nano, NexJet, OmniScan, OptiMix,OptiStroke, Partnership+Plus, PatternJet, PatternPro, PCI, Pinnacle, Plasmod, Powder Pilot, Powder Port, Powercure, Process Sentry, Pulse Spray,

PURBlue, PURJet, Ready Coat, RediCoat, RollVIA, Royal Blue, Select Series, Sensomatic, Shaftshield, SheetAire, Smart, Smartfil, SolidBlue, Spectral,SpeedKing, Spray Works, Summit, SureFoam, Sure Mix, SureSeal, Swirl Coat, TAH, ThruWave, Trade Plus, Trilogy, Ultra FoamMix, UltraMax, Ultrasaver,

Ultrasmart, Universal, ValueMate, Versa, Vista, Web Cure, YESTECH, and 2 Rings (Design) are trademarks of Nordson Corporation.

Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes,could lead to violation of the owners' rights.

Page 3: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Table of Contents i

Part 1054600_06E 2015 Nordson Corporation

Table of ContentsSafety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety Alert Symbols 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Responsibilities of the Equipment Owner 2. . . . . . . . . . . . . . . . . . . . . . . . .

Safety Information 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Instructions, Requirements, and Standards 2. . . . . . . . . . . . . . . . . . . .User Qualifications 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Applicable Industry Safety Practices 3. . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use of the Equipment 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Instructions and Safety Messages 4. . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation Practices 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operating Practices 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maintenance and Repair Practices 5. . . . . . . . . . . . . . . . . . . . . . . . . . .

Equipment Safety Information 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Equipment Shutdown 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Relieving System Hydraulic Pressure 6. . . . . . . . . . . . . . . . . . . . . . .De-energizing the System 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Disabling the Applicators 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Safety Warnings and Cautions 7. . . . . . . . . . . . . . . . . . . . . . . .Other Safety Precautions 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .First Aid 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Labels and Tags 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Supporting Documentation 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Interface Characteristics 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RJ45 (Standard) Connection 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ethernet Service Kit 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ethernet/IP Card Installation 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Install the Card 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Check the Installation 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Set the Field Bus Device Addresses 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IP address 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Subnet Mask 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Special case IP addresses 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Configuring the IP Address 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using the Configuration Switch 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using DHCP/BootP 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Using a Predefined Configuration 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Using the Address Resolution Protocol (ARP) 18. . . . . . . . . . . . . . . . . . .

Page 4: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Table of Contentsii

Part 1054600_06 E 2015 Nordson Corporation

Example: 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DNS Support 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Primary and Secondary DNS (a.k.a DNS1 and DNS2) 19. . . . . . . . . . .Host / Domain Names Conventions 19. . . . . . . . . . . . . . . . . . . . . . . . . . .

Example: 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Obtain the Device Master File 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Configure Files 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

`ethcfg.cfg' 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ip_accs.cfg 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Status Indicators 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LED 1 - Link (Activity) 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LED 2 - Link (Module Status) 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LED 3 - Link (Network Status) 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LED 4 - Activity 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Formatting the File System 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Data Security 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Password Files 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ad_pswd.cfg and sys_pswd.cfg 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example: 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FTP Server 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Email Client 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sending a predefined email on data event 26. . . . . . . . . . . . . . . . . . . . . .Example: 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Optional Functionality 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Communication Failure Alert 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Melter Control Panel Lock-out 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Melter Operational Modes 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Local Mode 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remote Mode 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indexed Data Interface 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indexed Protocol Data Processing 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transmit and Receive Packets 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transmit packet Data 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Melter Control 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Command 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Data Index 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Channel Number 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Write Data Value 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Receive Packet Data 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Status 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Read Data Value 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indexed Packet Examples 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example 1 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example 2 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Example 3 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Table of Contents iii

Part 1054600_06E 2015 Nordson Corporation

Full Map Data Interface 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Full Map Packet Processing 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transmit and Receive Packets 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Full Map Packet Data 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Melter Control 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Status 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Master Procedures 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Master: Determine Transmit Packet 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Melter: Process a New Packet 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Master: Evaluate the Receive Packet 48. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Channel Number List 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Blue Ethernet Data List 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Melter Data 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Seven-Day Clock Data 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PML Data 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Temperature Data 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Table of Contentsiv

Part 1054600_06 E 2015 Nordson Corporation

Page 7: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 1

Part 1054600_06E 2015 Nordson Corporation

Ethernet/IP Fieldbus Interface Card

SafetyRead this section before using the equipment. This section containsrecommendations and practices applicable to the safe installation, operation,and maintenance (hereafter referred to as “use”) of the product described inthis document (hereafter referred to as “equipment”). Additional safetyinformation, in the form of task-specific safety alert messages, appears asappropriate throughout this document.

WARNING! Failure to follow the safety messages, recommendations, andhazard avoidance procedures provided in this document can result inpersonal injury, including death, or damage to equipment or property.

Safety Alert SymbolsThe following safety alert symbol and signal words are used throughout thisdocument to alert the reader to personal safety hazards or to identifyconditions that may result in damage to equipment or property. Comply withall safety information that follows the signal word.

WARNING! Indicates a potentially hazardous situation that, if not avoided,can result in serious personal injury, including death.

CAUTION! Indicates a potentially hazardous situation that, if not avoided,can result in minor or moderate personal injury.

CAUTION! (Used without the safety alert symbol) Indicates a potentiallyhazardous situation that, if not avoided, can result in damage to equipment orproperty.

Page 8: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card2

Part 1054600_06 E 2015 Nordson Corporation

Responsibilities of the Equipment OwnerEquipment owners are responsible for managing safety information, ensuringthat all instructions and regulatory requirements for use of the equipment aremet, and for qualifying all potential users.

Safety InformationS Research and evaluate safety information from all applicable sources,

including the owner-specific safety policy, best industry practices,governing regulations, material manufacturer's product information, andthis document.

S Make safety information available to equipment users in accordance withgoverning regulations. Contact the authority having jurisdiction forinformation.

S Maintain safety information, including the safety labels affixed to theequipment, in readable condition.

Instructions, Requirements, and StandardsS Ensure that the equipment is used in accordance with the information

provided in this document, governing codes and regulations, and bestindustry practices.

S If applicable, receive approval from your facility's engineering or safetydepartment, or other similar function within your organization, beforeinstalling or operating the equipment for the first time.

S Provide appropriate emergency and first aid equipment.S Conduct safety inspections to ensure required practices are being

followed.S Re-evaluate safety practices and procedures whenever changes are

made to the process or equipment.

Page 9: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 3

Part 1054600_06E 2015 Nordson Corporation

User QualificationsEquipment owners are responsible for ensuring that users:S receive safety training appropriate to their job function as directed by

governing regulations and best industry practicesS are familiar with the equipment owner's safety and accident

prevention policies and proceduresS receive equipment and task-specific training from another qualified

individualNOTE: Nordson can provide equipment-specific installation,operation, and maintenance training. Contact your Nordsonrepresentative for information

S possess industry- and trade-specific skills and a level of experienceappropriate to their job function

S are physically capable of performing their job function and are notunder the influence of any substance that degrades their mentalcapacity or physical capabilities

Applicable Industry Safety PracticesThe following safety practices apply to the use of the equipment in themanner described in this document. The information provided here is notmeant to include all possible safety practices, but represents the best safetypractices for equipment of similar hazard potential used in similar industries.

Intended Use of the EquipmentS Use the equipment only for the purposes described and within the limits

specified in this document.S Do not modify the equipment.S Do not use incompatible materials or unapproved auxiliary devices.

Contact your Nordson representative if you have any questions onmaterial compatibility or the use of non-standard auxiliary devices.

Page 10: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card4

Part 1054600_06 E 2015 Nordson Corporation

Instructions and Safety MessagesS Read and follow the instructions provided in this document and other

referenced documents.S Familiarize yourself with the location and meaning of the safety warning

labels and tags affixed to the equipment. Refer to Safety Labels and Tagsat the end of this section.

S If you are unsure of how to use the equipment, contact your Nordsonrepresentative for assistance.

Installation PracticesS Install the equipment in accordance with the instructions provided in this

document and in the documentation provided with auxiliary devices.S Ensure that the equipment is rated for the environment in which it will be

used. This equipment has not been certified for compliance with theATEX directive nor as nonincendive and should not be installed inpotentially explosive environments.

S Ensure that the processing characteristics of the material will not create ahazardous environment. Refer to the Safety Data Sheet (SDS) for thematerial.

S If the required installation configuration does not match the installationinstructions, contact your Nordson representative for assistance.

S Position the equipment for safe operation. Observe the requirements forclearance between the equipment and other objects.

S Install lockable power disconnects to isolate the equipment and allindependently powered auxiliary devices from their power sources.

S Properly ground all equipment. Contact your local building codeenforcement agency for specific requirements.

S Ensure that fuses of the correct type and rating are installed in fusedequipment.

S Contact the authority having jurisdiction to determine the requirement forinstallation permits or inspections.

Operating PracticesS Familiarize yourself with the location and operation of all safety devices

and indicators.S Confirm that the equipment, including all safety devices (guards,

interlocks, etc.), is in good working order and that the requiredenvironmental conditions exist.

S Use the personal protective equipment (PPE) specified for each task.Refer to Equipment Safety Information or the material manufacturer'sinstructions and SDS for PPE requirements.

S Do not use equipment that is malfunctioning or shows signs of a potentialmalfunction.

Page 11: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 5

Part 1054600_06E 2015 Nordson Corporation

Maintenance and Repair PracticesS Allow only personnel with appropriate training and experience to operate

or service the equipment.S Perform scheduled maintenance activities at the intervals described in

this document.S Relieve system hydraulic and pneumatic pressure before servicing the

equipment.S De-energize the equipment and all auxiliary devices before servicing the

equipment.S Use only new Nordson-authorized refurbished or replacement parts.S Read and comply with the manufacturer's instructions and the SDS

supplied with equipment cleaning compounds.NOTE: SDSs for cleaning compounds that are sold by Nordson areavailable at www.nordson.com or by calling your Nordson representative.

S Confirm the correct operation of all safety devices before placing theequipment back into operation.

S Dispose of waste cleaning compounds and residual process materialsaccording to governing regulations. Refer to the applicable SDS orcontact the authority having jurisdiction for information.

S Keep equipment safety warning labels clean. Replace worn or damagedlabels.

Equipment Safety InformationThis equipment safety information is applicable to the following types ofNordson equipment:S hot melt and cold adhesive application equipment and all related

accessoriesS pattern controllers, timers, detection and verification systems, and all

other optional process control devices

Page 12: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card6

Part 1054600_06 E 2015 Nordson Corporation

Equipment ShutdownTo safely complete many of the procedures described in this document, theequipment must first be shut down. The level of shut down required varies bythe type of equipment in use and the procedure being completed.If required, shut down instructions are specified at the start of the procedure.The levels of shut down are:

Relieving System Hydraulic PressureCompletely relieve system hydraulic pressure before breaking any hydraulicconnection or seal. Refer to the melter-specific product manual forinstructions on relieving system hydraulic pressure.

De-energizing the SystemIsolate the system (melter, hoses, applicators, and optional devices) from allpower sources before accessing any unprotected high-voltage wiring orconnection point.1. Turn off the equipment and all auxiliary devices connected to the

equipment (system).2. To prevent the equipment from being accidentally energized, lock and

tag the disconnect switch(es) or circuit breaker(s) that provide inputelectrical power to the equipment and optional devices.NOTE: Government regulations and industry standards dictate specificrequirements for the isolation of hazardous energy sources. Refer to theappropriate regulation or standard.

Disabling the Applicators

NOTE: Adhesive dispensing applicators are referred to as “guns” in someprevious publications.

All electrical or mechanical devices that provide an activation signal to theapplicators, applicator solenoid valve(s), or the melter pump must bedisabled before work can be performed on or around an applicator that isconnected to a pressurized system.1. Turn off or disconnect the applicator triggering device (pattern controller,

timer, PLC, etc.).2. Disconnect the input signal wiring to the applicator solenoid valve(s).3. Reduce the air pressure to the applicator solenoid valve(s) to zero; then

relieve the residual air pressure between the regulator and the applicator.

Page 13: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 7

Part 1054600_06E 2015 Nordson Corporation

General Safety Warnings and CautionsTable 1 contains the general safety warnings and cautions that apply toNordson hot melt and cold adhesive equipment. Review the table andcarefully read all of the warnings or cautions that apply to the type ofequipment described in this manual.

Equipment types are designated in Table 1 as follows:HM = Hot melt (melters, hoses, applicators, etc.)PC = Process controlCA = Cold adhesive (dispensing pumps, pressurized container, andapplicators)

Table 1 General Safety Warnings and CautionsEquipment

Type Warning or Caution

HM

WARNING! Hazardous vapors! Before processing any polyurethanereactive (PUR) hot melt or solvent-based material through a compatibleNordson melter, read and comply with the material's SDS. Ensure thatthe material's processing temperature and flashpoints will not beexceeded and that all requirements for safe handling, ventilation, firstaid, and personal protective equipment are met. Failure to comply withSDS requirements can cause personal injury, including death.

HMWARNING! Reactive material! Never clean any aluminum componentor flush Nordson equipment with halogenated hydrocarbon fluids.Nordson melters and applicators contain aluminum components thatmay react violently with halogenated hydrocarbons. The use ofhalogenated hydrocarbon compounds in Nordson equipment cancause personal injury, including death.

HM, CA WARNING! System pressurized! Relieve system hydraulic pressurebefore breaking any hydraulic connection or seal. Failure to relieve thesystem hydraulic pressure can result in the uncontrolled release of hotmelt or cold adhesive, causing personal injury.

Continued...

Page 14: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card8

Part 1054600_06 E 2015 Nordson Corporation

General Safety Warnings and Cautions (contd)Table 1 General Safety Warnings and Cautions (contd)

EquipmentType Warning or Caution

HMWARNING! Molten material! Wear eye or face protection, clothing thatprotects exposed skin, and heat-protective gloves when servicingequipment that contains molten hot melt. Even when solidified, hot meltcan still cause burns. Failure to wear appropriate personal protectiveequipment can result in personal injury.

HM, PCWARNING! Equipment starts automatically! Remote triggering devicesare used to control automatic hot melt applicators. Before working onor near an operating applicator, disable the applicator's triggeringdevice and remove the air supply to the applicator's solenoid valve(s).Failure to disable the applicator's triggering device and remove thesupply of air to the solenoid valve(s) can result in personal injury.

HM, CA, PC

WARNING! Risk of electrocution! Even when switched off andelectrically isolated at the disconnect switch or circuit breaker, theequipment may still be connected to energized auxiliary devices.De-energize and electrically isolate all auxiliary devices beforeservicing the equipment. Failure to properly isolate electrical power toauxiliary equipment before servicing the equipment can result inpersonal injury, including death.

HM, CA, PC

WARNING! Risk of fire or explosion! Nordson adhesive equipment isnot rated for use in explosive environments and has not been certifiedfor the ATEX directive or as nonincendive. In addition, this equipmentshould not be used with solvent-based adhesives that can create anexplosive atmosphere when processed. Refer to the SDS for theadhesive to determine its processing characteristics and limitations.The use of incompatible solvent-based adhesives or the improperprocessing of solvent-based adhesives can result in personal injury,including death.

HM, CA, PCWARNING! Allow only personnel with appropriate training andexperience to operate or service the equipment. The use of untrainedor inexperienced personnel to operate or service the equipment canresult in injury, including death, to themselves and others and candamage to the equipment.

Page 15: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 9

Part 1054600_06E 2015 Nordson Corporation

Warning or CautionEquipmentType

HMCAUTION! Hot surfaces! Avoid contact with the hot metal surfaces ofapplicators, hoses, and certain components of the melter. If contactcan not be avoided, wear heat-protective gloves and clothing whenworking around heated equipment. Failure to avoid contact with hotmetal surfaces can result in personal injury.

HM

CAUTION! Some Nordson melters are specifically designed toprocess polyurethane reactive (PUR) hot melt. Attempting to processPUR in equipment not specifically designed for this purpose candamage the equipment and cause premature reaction of the hot melt. Ifyou are unsure of the equipment's ability to process PUR, contact yourNordson representative for assistance.

HM, CA

CAUTION! Before using any cleaning or flushing compound on or inthe equipment, read and comply with the manufacturer's instructionsand the SDS supplied with the compound. Some cleaning compoundscan react unpredictably with hot melt or cold adhesive, resulting indamage to the equipment.

HM

CAUTION! Nordson hot melt equipment is factory tested with NordsonType R fluid that contains polyester adipate plasticizer. Certain hot meltmaterials can react with Type R fluid and form a solid gum that canclog the equipment. Before using the equipment, confirm that the hotmelt is compatible with Type R fluid.

Page 16: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card10

Part 1054600_06 E 2015 Nordson Corporation

Other Safety PrecautionsS Do not use an open flame to heat hot melt system components.S Check high pressure hoses daily for signs of excessive wear, damage, or

leaks.S Never point a dispensing handgun at yourself or others.S Suspend dispensing handguns by their proper suspension point.

First AidIf molten hot melt comes in contact with your skin:1. Do NOT attempt to remove the molten hot melt from your skin.2. Immediately soak the affected area in clean, cold water until the hot melt

has cooled.3. Do NOT attempt to remove the solidified hot melt from your skin.4. In case of severe burns, treat for shock.5. Seek expert medical attention immediately. Give the SDS for the hot melt

to the medical personnel providing treatment.

Safety Labels and TagsRefer to the melter product manual for the location of the product safetylabels and tags affixed to the equipment.

Page 17: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 11

Part 1054600_06E 2015 Nordson Corporation

DescriptionSee Figure 1.

The Ethernet/IP field bus card is used in field bus systems to centrally collectand process data. The cards operate through the master-slave accessmethod. When used in a field bus system, Nordson melters always operateas slaves.

Although most melter functionality can be set/monitored using field buscommunications, some functionality is considered inconsistent with field bususage and is therefore not accessible. Non-supported melter functions are:S ClockS Password protectionS PID selection (DuraBlue melters only)S pump-off delay (DuraBlue melters only)S Hose 1 and 2 solenoid activation (DuraBlue melters only)

Figure 1 Typical field bus card

Intended UseThis manual is intended for use by experienced PLC engineers.

The Ethernet/IP field bus card is intended to be used only as described in thismanual. Any other use is considered to be unintended. Nordson is not liablefor personal injury or property damage resulting from unintended use.Intended use includes the observance of Nordson safety regulations.

Page 18: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card12

Part 1054600_06 E 2015 Nordson Corporation

Supporting DocumentationThe following documentation should be used in conjunction with this manual:

Title Publisher LocationBlue Ethernet Data List n/a End of this manualMelter Product Manual Nordson Shipped with melterDrum Unloader Product Manual Nordson Shipped with Drum UnloaderOpen Modbus/TCP Specification Schneider Automation www.modbus.orgRFC-821 Network Working Group n/aRFC-1918 Network Working Group n/aENIP Specifications Control/Net International and

ODVAwww.odva.org

Interface CharacteristicsS RJ45S Data:

- Status information- Alarms and faults- Actual values- Setpoint values- Limit parameters

S Integrated FTP serverS Telnet using standard MS DOS-type command line interfaceS Web Server can serve web pages for a user friendly interface as well as

remote troubleshooting (web pages provided by Nordson Corporation)S To view web pages go to http://<melter_IP_address>S To view web pages from outside your company's firewall, special

arrangements may be needed for access to your melter. Consult yourIT department.

S DNS supportS e-mail clientS Security framework

Page 19: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 13

Part 1054600_06E 2015 Nordson Corporation

RJ45 (Standard) ConnectionPin Signal1 TD+2 TD-3 RD+4 Termination5 Termination6 RD-7 Termination8 Termination

Ethernet Service KitKIT,CIRCUIT BOARD,ETHERNET CARD, P/N 1053289.

Page 20: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card14

Part 1054600_06 E 2015 Nordson Corporation

Ethernet/IP Card InstallationInstall the Card

See Figures 2 and 3.

Install the Ethernet/IP card onto the melter CPU board observing thefollowing guidelines. Route the Ethernet cable out of the electrical enclosurethrough one of the available conduit knockouts on the base or left side of themelter.

Figure 2 From left to right: Location of the CPU board on the ProBlue, DuraBlue, and DuraBlue 25/50/100

CPU

Figure 3 Attaching the Ethernet/IP card to the melter CPU

Page 21: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 15

Part 1054600_06E 2015 Nordson Corporation

Check the InstallationPower on the melter and observe the red/green watchdog LED on the backof the Ethernet/IP card. See Table 2.

Table 2 Watchdog LED IndicationsIndication LED Color Frequency

ASIC and FLASHROM check fault

Red 2 Hz

Module not initiated Green 2 HzModule initialized andrunning OK

Green 1 Hz

RAM check fault Red 1 HzDPRAM check fault Red 4 Hz

Set the Field Bus Device Addresses

IP addressThe IP address is used to identify each node on the TCP/IP network.Therefore, each node on the network must have a unique IP address. IPaddresses are written as four decimal integers (0-255) separated by periods,where each integer represents the binary value of one byte in the IP address.This is called dotted-decimal notation.

Example:Address 10000000 00001010 00000010 00011110 is written as 128.10.2.30

Subnet MaskThe IP address is divided into three parts - net ID, subnet ID and host ID. Toseparate the net ID and the subnet ID from the host ID, a subnet mask isused.

The subnet mask is a 32-bit binary pattern, where a set bit allocates a bit fornetwork/subnet ID, and a cleared bit allocates a bit for the host ID. Like the IPaddress, the subnet mask is commonly written in dotted-decimal notation.

Example:To make the IP address 128.10.2.30 belong to subnet 128.10.2, the subnetmask shall be set to 255.255.255.0.

Subnet Mask: 11111111 11111111 1111111 00000000 (255.255.255.0)

Page 22: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card16

Part 1054600_06 E 2015 Nordson Corporation

Subnet Mask (contd)NOTE: To be able to establish communication between two devices bothdevices must belong to the same subnet. If not, the communication must bedone through a gateway. It is therefore recommended to configure themodule to the same subnet as your PC.

Special case IP addressesDevices on an Ethernet network are not allowed to be configured to thefollowing IP addresses; therefore do not configure the module to use any ofthem.

0.x.x.x - IP address where the first byte is zero

127.x.x.x - IP address where the first byte is 127

x.x.x.0 - IP address where the last byte is zero

x.x.x.255 - IP address where the last byte is 255

Configuring the IP AddressThe module offers several ways to configure the IP address:S Configuration SwitchS DHCP/BootPS Using a predefined IP address stored in the file `ethcfg.cfg'.S ARP

Using the Configuration SwitchThe configuration switch provides an easy way to configure the module forintranet use. The switch represents the binary value of the last byte in the IPaddress.

If the switch is set to a value between 1–255, the module will use the stringsdescribed below.S IP address: 192.168.0.nS Subnet mask: 255.255.255.0S Gateway address: 0.0.0.0 (No gateway set)

The last byte (n) represents the binary value of the switches. Subnet maskand Gateway address settings are fixed to the above values when using theconfiguration switches.

Page 23: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 17

Part 1054600_06E 2015 Nordson Corporation

Example:The switches are set to 00010100 (20 decimal)

The IP address of the module will be set to 192.168.0.20

NOTE: These settings can only be used on an intranet. This is because theIP address that is being set belongs to the private address set, refer to RFC1918.

Using DHCP/BootPIf the configuration switch is set to 0, the module will use the configurationstored in the file `ethcfg.cfg'.

If DHCP/BootP is enabled in the configuration file `ethcfg.cfg' or if theconfiguration file is missing, the module will attempt to retrieve the followinginformation via DHCP/BootP:S IP addressS Subnet maskS Gateway addressS SMTP server addressS Default Domain NameHost NameS DNS server (Primary and secondary)

The retrieved information will be stored in the configuration file `ethcfg.cfg'¨

NOTE: The module supports DHCP Reboot, i.e. it will ask the DHCP/BootPfor the IP address stored in the configuration file. If the address is free to use,it will be assigned to the module. If not, the module will be assigned a newaddress.

Using a Predefined ConfigurationIf the configuration switch is set to 0, the module will use the configurationstored in the file `ethcfg.cfg'.

If DHCP/BootP is disabled or a DHCP/BootP server cannot be found, themodule will try to use the configuration stored in the file `ethcfg.cfg'. If this fileis missing, the module will indicate an error on the Network Status LED. Inthis state, the module will only run the ARP protocol.

Page 24: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card18

Part 1054600_06 E 2015 Nordson Corporation

Using the Address Resolution Protocol (ARP)The IP address can be changed during runtime using the ARP commandfrom a PC. The new IP address will be stored in the configuration file`ethcfg.cfg'.

Below is an example on how to change the IP address from a MS DOSwindow:

arp -s <IP address> <MAC address>

ping <IP address>

arp -d <IP address>

The arp -s command will store the IP and MAC addresses in the PC's ARPtable. When the ping command is executed, the PC sends this information tothe module using the MAC address. The module detects that it wasaddressed with the correct MAC address and adopts the IP address sent bythe PC. (The arp -d command is optional, but it removes the static route fromthe PC ARP table). The new IP address will be stored in the configuration file`ethcfg.cfg'.

This method can be used to reconfigure modules that already have beenconfigured, or even to reconfigure modules outside the host's subnet.The MAC address is printed on a label on the bottom side of the module.

NOTE: As the Arp command automatically configures the subnet mask to255.255.255.0, the first three bytes of the IP address must be the same as forthe PC executing the command.

Example:PC - 10.10.12.67

Module - 10.10.12.x (Where x is a value between 1 and 254)

DNS Support

IntroductionDNS is a service that translates host names into IP addresses. Becausedomain names are alphabetic, they're much easier to remember. Every timea host name is used, a DNS service must translate the name into thecorresponding IP address.

If a DNS server doesn't know how to translate a particular domain name, itwill ask another one until the corresponding IP address is found.

The DNS configuration is specified in the configuration file `ethcfg.cfg'.

Page 25: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 19

Part 1054600_06E 2015 Nordson Corporation

Primary and Secondary DNS (a.k.a DNS1 and DNS2)It is possible to define two DNS servers in the module, a primary and asecondary. When a domain name should be translated, the module will askthe primary DNS server. If it for some reason fails to process the request, themodule will retry using the secondary DNS.

Host / Domain Names ConventionsBefore a request is sent to a DNS server, the module will process the hostname as follows:S If the hostname does not contain a dot, the module will automatically

append the default domainS If the hostname ends with a dot, that dot will automatically be

removed.S If the hostname contains a dot but isn't ending with one, the module

will...- send a request to the DNS server for the hostname- if that request fails, append the default domain name and try

again

Example:(In the examples below, the default domain name is `hms.com')S `test' becomes `test.hms.com'S `test.hms.com.' becomes `test.hms.com'S `test.a' will if not found become `test.a.hms.com'

Obtain the Device Master FileNordson Corporation provides a device master (.EDS) for the technicaldescription of the Ethernet/IP card described in this manual. The format isbased on the standard EN 50170. The .EDS file may be downloaded fromwww.enordson.com/support.

Configure FilesThe module uses these files for configuration purposes. The configurationfiles are ASCII files and can be edited with any text editor. Depending onsecurity settings, the files may be inaccessible for normal users. Generally,the module has to be restarted in order for any changes in these files to haveeffect.

NOTE: It is very important to follow the exact syntax specifications for eachconfiguration file, otherwise the module might have problems interpreting it,which can result in a faulty or non-expected behavior.

Page 26: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card20

Part 1054600_06 E 2015 Nordson Corporation

`ethcfg.cfg'This file contains the network configuration and is read by the module at startup. The settings in this file may be affected by several mailbox- and SSIcommands. For more information about network configuration refer toConfiguring the IP Address.

The format of the file is the following:

[IP address]10.10.12.212

[Subnet mask]255.255.255.0

[Gateway address]0.0.0.0

[DHCP/BOOTP]OFF

[Speed]Auto

[Duplex]Auto

[SMTP address]0.0.0.0

[SMTP username]username

[SMTP password]password

[DNS1 address]0.0.0.0

[DNS2 address]0.0.0.0

[Domain name]yourcompany.com

[Host name]Nordson_Melter

The contents of this file can be redirected by placing the line `[File path]' onthe first row, and a file path on the second.

Page 27: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 21

Part 1054600_06E 2015 Nordson Corporation

Example:[File path]\user\eth_settings.cfg

In this example, the settings described above will be loaded from the file`user\eth_settings.cfg'. This permits normal users to access the networkconfiguration settings.

ip_accs.cfgIt is possible to configure which IP addresses and what protocols that areallowed to connect to the module. This information is stored in the file`\ip_accs.cfg'. The file contains one or several of the headers below.

[Web][FTP][Telnet][Modbus/TCP][All]

Under each header the allowed IP addresses are written. The wildcard `*'can be used to allow series of IP addresses. If a protocol header is not given,the system will use the configuration set below the header `All'. If the `All'header is not given, the protocol will not accept any connections.

Example:[Web]10.10.12.*10.10.13.*[FTP]10.10.12.*[Telnet]10.10.12.*[All]

The above example will allow all IP addresses beginning with 10.10.12 toaccess all protocols in the module. Addresses beginning with 10.10.13 willbe able to access the web server, but not the FTP and Telnet servers. TheModbus/TCP server will accept connections from any IP address.

The contents of this file can be redirected by placing the line `[File path]' onthe first row, and a file path on the second.

Example:[File path]\my_settings\ip_access_rights.cfg

In this example, the settings described above will be loaded from the file`\my_settings\ip_access_rights.cfg'.

Page 28: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

LED indicators

Ethernet/IP Fieldbus Interface Card22

Part 1054600_06 E 2015 Nordson Corporation

Status IndicatorsLEDs 1–4 indicate run time status and errors to the user. During power up, aled test sequence is performed according to the EtherNet/IP specification.

LED 1 - Link (Activity)Color State Indicates

Green On The module has a linkOff The module does not

sense a link

LED 2 - Link (Module Status)State Summary Description

Steady Off No power No power applied tothe module

Steady Green Device operational The module isoperating correctly

Flashing Green Standby The module has notbeen configured

Flashing Red Minor fault A minor recoverablefault has beendetected

Steady Red Major fault A major internal errorhas been detected

Flashing Green/Red Self-test The module isperforming a power onself-test

Page 29: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 23

Part 1054600_06E 2015 Nordson Corporation

LED 3 - Link (Network Status)State Summary Description

Steady Off No power or no IPaddress

The module has no power orno IP address

Steady Green Connected The module has at least oneestablished Ethernet/IPconnection.

Flashing Green No connection There are no Ethernet/IPconnections established tothe module

Flashing Red Connectiontimeout

One or more of theconnections in which themodule is the target has timedout. This state is only left if alltimed out connections arere-established or if the moduleresets

Steady Red Duplicate IP The module detected that itsIP address is already in use

FlashingGreen/Red

Self-test The module is performing apower self-test

LED 4 - ActivityThe Activity LED flashes green each time a packet is received or transmitted.

Formatting the File SystemIf the module refuses to start up, this may be due to an error in the filesystem. The steps below can be used to format and restore the file system toits initial state.1. Short jumper named ”J2”2. Apply power to the module3. Wait for the watchdog led to turn red4. Disconnect the power5. Remove jumper6. Again, apply power to the module7. Wait approximately 1 minute as the module is formatting the file system

The module should now be working properly, however all files and folders inthe file system have been erased.

Page 30: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card24

Part 1054600_06 E 2015 Nordson Corporation

Data SecurityThe file system features two security levels; Admin and Normal. Securitylevel is set at a per user basis.S Admin Mode

Admin users has full access to the file system through FTP and Telnet.This enables the user to access areas of the file system, that is restrictedor inaccessible in Normal mode.

The Admin user accounts are defined in the file `ad_pswd.cfg'.S Normal Mode

This mode is recommended for normal operation, so that web pages andother settings are protected from FTP and Telnet access.The accounts for normal users are defined in the file `sys_pswd.cfg'.

Files within the file system can be protected from web access throughusername/password authorization. Refer to Password Files.

Page 31: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 25

Part 1054600_06E 2015 Nordson Corporation

Password Files

ad_pswd.cfg and sys_pswd.cfgUser/password information for FTP and Telnet is stored in the files`sys_pswd.cfg' (Normal users) and `ad_pswd.cfg' (Admin users). These filesmust be placed in `\user\pswd' and `\pswd\ respectively. These directoriesare protected from web browser access.

The file format is the following:

User1:password1User2:password2...User3:password3

Example:User: Password

In this example, the username is `User', and the password is `Password'.

If no `:' is present, the password will be equal to the username.

Example:Username

In this example, both username and password will be `Username'.

FTP ServerIt is possible to upload/download files to/from the file system using astandard FTP client. Depending on security settings, different parts of the filesystem can be accessed by the user:S Normal users

The root directory will be `\user' unless the user has Admin access rights,see below.

S Admin usersThe user will have unrestricted access to the file system, i.e. the rootdirectory will be `\'.

S Global Admin ModeAny username/password combination will be accepted. All users haveunrestricted access to the file system, i.e. the root directory will be `\'.

For more information about the security framework in the module, see SeeSecurity.

Page 32: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card26

Part 1054600_06 E 2015 Nordson Corporation

Email ClientIt is possible to send emails from the module. To send an email, the SMTPserver address must be configured. Without a valid SMTP address themodule will not be able to send any email messages.

Sending a predefined email on data eventIt is possible to send predefined email messages, triggered by a value in theEthernet/IP Data List. It is possible to have up to 10 user defined, and 10admin defined emails, triggered on different events. These shall be placed inthe directories ”\user\email\” for user configurable emails and ”\email” fornon-user configurable emails. The files must be named `email_1.cfg',`email_2.cfg' ... `email_10.cfg'.

The files shall have the following format:

[Register]Area, Data Location, Type

[Register match]Match Value, Mask, Match operand

[To]Recipient(s)

[From]Sender

[Subject]Subject line

[Headers]Extra Headers

[Message]Message body

Page 33: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 27

Part 1054600_06E 2015 Nordson Corporation

Parameter DescriptionArea Source area in Fieldbus card

memory. POssible values are “IN” or“OUT” from master's viewpoint. Usu-ally “IN” is used.

Data Location Data location value in memory areafor the indexed protocol, only the“Status” work (bytes 0 and 1) isrelevant. For the full map, calculatethe data location by the followingformula:Data Location=(2xFull Map WordOffset) +16

Type Source data type. Possible valuesare `byte', `word', and `long'

Match Value Value to compare with the sourcedata. Shall be written in decimal orhexadecimal.

Mask The module performs a logical `and'on the source data and this Maskbefore the value is

compared with the Match Value. The value shall be written in decimal orhexadecimal.Match Operand Specifies how the data shall be

compared with the Match Value.Possible values: `<`, `=', `>'

Recipient(s) Destination email addresses, semi-colon separated

Sender Sender email addressSubject line Email subject (One line only)Extra Headers Optional. May be useful for ad-

vanced users when for examplesending HTML emails etc.

The data is read in the Data List from the area and offset specified by theparameters Area, and Offset. The datasize to read is specified by the Typeparameter. The module performs a logical `AND' between the read data andthe parameter Mask. The result is compared with the parameter MatchValue. How the data shall be compared is specified by the Match Operand.

NOTE: If the [Register] or [Register match] information is changed, a reset isrequired for changes to take effect. Other changes will take effect directlywithout a reset.

Page 34: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card28

Part 1054600_06 E 2015 Nordson Corporation

Sending a predefined email on data event (contd)

Example:

[Register]IN, 0x0003, byte

[Register match]0x20, 0x7F, >

[To][email protected]

[From][email protected]

[Subject]Status

[Message]All data correct.

NOTE: Hexadecimal values must be written in the format 0xN where `N' isthe hexadecimal value.

Optional FunctionalityCommunication Failure Alert

Melter fault code F4/E indicates that the melter has lost communications withthe Fieldbus. Refer to the melter manual for troubleshooting information.

Melter Control Panel Lock-outWhen password protection (parameters 10 and 11) are enabled with aFieldbus card installed, all operator panel controls are disabled.

Page 35: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 29

Part 1054600_06E 2015 Nordson Corporation

Melter Operational ModesMelters with a field bus card have two operational modes: local and remote.The default is the remote mode. The mode may be selected through themelter operator panel.

NOTE: For the remainder of this manual, the term “field bus” is used to referto the the Ethernet/IP system.

Local ModeThe local mode of operation is used mainly to view data for maintenance andrepair purposes. In this mode, the melter operates like a melter that does notinclude a field bus card:S Control access is only via the melter operator panelS Parameter input is only via the melter operator panelS Through the master, all parameters can be displayed but not

changed. The master can always read actual values.To place the melter in the local mode, change Parameter 14 (External CommLockout) to 1.

Remote ModeWhen the melter is in the remote mode of operation, it can be operated fromboth the master and the melter operator panel:S Setpoints and system parameters can be entered through the master

or the melter operator panel.S If control of the melter exclusively through the master is desired, you

can enable password protection (melter operating parameters 10 and11), which locks-out operation of the melter using the operator panel.Refer to the melter product manual for information on enablingpassword protection.NOTE: When a field bus card is installed in the melter, enablingpassword protection will disable all melter operator panel input,including the Heaters, Pump, and Standby keys.

To place the melter in the remote mode, change Parameter 14 (ExternalComm Lockout) to 0. This is the default setting.

Page 36: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card30

Part 1054600_06 E 2015 Nordson Corporation

Indexed Data InterfaceWhen data is transmitted from the Nordson melter to the master and viceversa, the data is accessed via indexes. The data available via the Fieldbusare shown in the Blue Ethernet Data List. The indexing method allows asmaller data packet which prevents the field bus from being loaded withunnecessary data.

Indexed Protocol Data ProcessingS The master formulates a command by determining the transmission data

packet. The Nordson melter processes the command and formulates thereply telegram.

S The master processes the data or repeats the command until a reply isreceived from the Nordson melter. Only one command is processed at atime. The Nordson melter keeps the reply available until the masterformulates a new command.

S When a Command can not be executed, the Nordson melter replies witha fault signal in the Status. The master recognizes by this identificationwhether the previously transmitted command was correctly processed bythe Nordson melter.

S The master has to check that the acknowledge data Data index andChannel number from the Nordson melter are the same as the data in thetransmission data packet.

Transmit and Receive PacketsThe master sends a transmission packet to the Nordson melter. This packetcontains a command that the Nordson melter is to process.

The following illustration shows an example of the reading out of temperatureactual values.

Mastertransmit packet

Command:Readactualtemperature

Nordson melter

Field bus system

Controlsystemwith fieldbus master

Figure 4 Example of master-to-melter communication

Page 37: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 31

Part 1054600_06E 2015 Nordson Corporation

The Nordson melter replies to each packet from the master with statusinformation on command processing. Requested data values are alsoreturned in the reply packet.

Masterreceive packet

Status: Ready

AData:ctual

temperature,channels 1 to n

Nordson melter

Controlsystemwith fieldbus master

Fieldbus

Figure 5 Example of melter-to-master communication

The master may not formulate and transmit a new command until after arrivalof the receive packet.

Page 38: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card32

Part 1054600_06 E 2015 Nordson Corporation

Transmit packet DataTable 3 lists the transmit packet data.S Communication is done with two data packets: Receive and Transmit

(from the master's viewpoint).S The Receive and Transmit data packets are instances 100 and 150

respectively.S The data packets always have the same length: 16 bytes, consistent.

Table 3 Transmit Packet DataByte

Address NByte (B),Word (W) Designation

N B Melter controlN + 1 B CommandN + 2 B Data indexN + 3 B Channel numberN + 4 W Write data value of channel numberN + 6 W Motor 1 speed in %N + 8 W Motor 2 speed in %N + 10 W Motor 3 speed in %N + 12 W Motor 4 speed in %N + 14 W Not used

NOTE: The master may need to swap bytes in some or all of the packetdata if the data formats of the master and the Nordson melter do notcorrespond.

Page 39: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 33

Part 1054600_06E 2015 Nordson Corporation

Melter ControlThe melter control data in the transmit packet is executed by the Nordsonmelter with each packet, regardless of the command type.

NOTE: Unused or reserved bits must be set to 0 (zero).

Table 4 Melter Control DataBit Value Action Note0 1 Heaters ON Heaters ON and

temperature standbyrequire a transitionfrom 0 to 1 foractivation.

0 Heaters OFF

1 1 All pumps ON0 All pumps OFF

2 1 Pump 1 ON0 Pump 1 OFF

3 1 Pump 2 ON(if available)

0 Pump 2 OFF(if available)

4 1 Pump 3 ON(if available)

0 Pump 3 OFF(if available)

5 1 Pump 4 ON(if available)

0 Pump 4 OFF(if available)

6 1 Temperaturestandby ON

Heaters ON andtemperature standbyrequire a transitionfrom 0 to 1 foractivation.

0 Temperaturestandby OFF

7 1 Auto Motor On Automatically turnsmotors on when unithas reached Ready

0 Auto Motor OFF

Page 40: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card34

Part 1054600_06 E 2015 Nordson Corporation

CommandThe master must send a command to the Nordson melter. Each command isdefined by a command identification.

Table 5 Command IdentificationsCommand Function

1 dec No command for the Nordson melter3 dec Master wants to read data from the Nordson melter6 dec Master wants to write data to the Nordson melter

Any other command identification is not valid and will generate acommunication fault in the status data packet.

If the command is 0 (zero), a “host communication failure” will be generatedat the melter. This functionality operates for communication monitoring andmaster life guarding.

Data IndexThe indexes in the data index packet correspond to those in the BlueEthernet Data List at the end of this section.

The range of data indexes is 0 to 255. A data index set to 0 (zero) isinterpreted as “no data index.”

Channel NumberThe master must select a channel number that is valid. Refer to ChannelNumber List later in this section for the channel number descriptions (such asfor a temperature channel).

Beginning with the selected channel number as a start channel, thecommand for reading data is processed for the six successive channels.

Write Data ValueIn the write data value data packet, the master writes the data values used toenter settings in the Nordson melter.

Example: Master sets the Ready Delay parameter to a value of 25 minutes.Transmit packet Data Channel Number Value

Write data value of channel number 0 25 dec (25min)

Page 41: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 35

Part 1054600_06E 2015 Nordson Corporation

Receive Packet DataTable 6 lists the receive packet data packets.

Table 6 Receive packet Data packetsByte

Address NByte (B),Word (W) Designation

N W StatusN + 2 B Acknowledge: Data indexN + 3 B Acknowledge: Channel numberN + 4 W Read data value of channel numberN + 6 W Read data value of channel number + 1N + 8 W Read data value of channel number + 2N + 10 W Read data value of channel number + 3N + 12 W Read data value of channel number + 4N + 14 W Read data value of channel number + 5

NOTE: The master may need to swap bytes in some or all of the packetdata if the data formats of the master and the Nordson melter do notcorrespond.

Page 42: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card36

Part 1054600_06 E 2015 Nordson Corporation

StatusThe status data in each receive packet communicates general informationfrom the Nordson melter.

Table 7 Status DataBit Value Action0 1 Ready for operation

0 Not ready for operation1 1 Pump Startup Protection On

0 Pump Startup Protection Off2 1 Alert

0 No alert3 1 Fault

0 No fault4 1 Shutdown

0 No shutdown5 1 Heat-up phase active

0 Heat-up phase not active6 1 Temperature standby on

0 Temperature standby off7 1 Pump 1 is running

0 Pump 1 is not running8 1 Pump 2 is running (if available)

0 Pump 2 is not running (if available)9 1 Pump 3 is running (if available)

0 Pump 3 is not running (if available)10 1 Pump 4 is running (if available)

0 Pump 4 is not running (if available)11 1 Not used

0 Not used

Page 43: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 37

Part 1054600_06E 2015 Nordson Corporation

Table 7 Status Data (contd)Bit Value Action12 - Reserved13 - Reserved14 1 Communication fault:

S Wrong command receivedS Wrong data index receivedS Wrong channel number received

0 No communication faults in packet header15 1 Communication fault in data value:

S Data values can not be changed.Example:Write command on actualvalues.

S Data access not permitted.Example:Write command in theLocal mode or commands forchannels that are not installed.

S At least one data value is invalid. Thedata packet received may not beevaluated by the master.Example: A value is outside of thepermitted value range.

0 No communication faults in data values

NOTE: Nordson melters are equipped with automatic Pump StartupProtection. The Pump Startup Protection prevents all stopped pumps (suchas those stopped as a result of an RTD fault) from starting up automaticallyafter finishing the heat-up phase or after a fault has occurred.To acknowledge the Pump Startup Protection, change the All PumpsON/OFF parameter from OFF to ON. (For a rising transition-based reset,refer toMelter Control. If bit1 = 0, then set to 1; if bit1 = 1, then set to 0 andsubsequently to 1 again.)

Page 44: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card38

Part 1054600_06 E 2015 Nordson Corporation

Read Data ValueIn the read data value area, the master reads the data received from theNordson melter. The read data values of six successive channels aretransmitted with each packet (where applicable).

Example:Master reads actual temperature values; channel number is setto 9.

Table 8 Read Data ValuesReceive packet Data Temperature Channel Value

Read data value of channel number 9 150 dec (150 _C)Read data value of channel number + 1 10 151 dec (151 _C)Read data value of channel number + 2 11 160 dec (160 _C)Read data value of channel number + 3 12 165 dec (165 _C)Read data value of channel number + 4 13 172 dec (172 _C)Read data value of channel number + 5 14 180 dec (180 _C)

NOTE: If the master sets the command or data index to 0 (zero) in thetransmit packet, the read data values are set to 0 (zero) from the melter.Example:Master sets data index to 0 (zero).

Transmit packetMelter control Command Data

IndexChannelNumber

Write Data Value ofChannel Number 1 2 3 4

0

Receive packet

Status Acknowledge:Data index

Acknowledge:Channel Number

Read Data Value of Channel Number+ 1 + 2 + 3 + 4 + 5

0001 hex 0 0 0 0 0 0 0

NOTE: If the transmit packet is faulty, the read data values are set to 0 (zero)from the Nordson melter.

Page 45: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 39

Part 1054600_06E 2015 Nordson Corporation

Example:Master sets data index to a fault value (999). The status of theNordson melter is ready for operation and communication fault: wrong dataindex.

Transmit packetMelter control Command Data

IndexChannelNumber

Write Data Value ofChannel Number 1 2 3 4

999

Receive packetStatus Acknowledge:

Data indexAcknowledge:

Channel NumberRead Data Value of Channel Number

+ 1 + 2 + 3 + 4 + 54001 hex 999 0 0 0 0 0 0

NOTE: Invalid read data values are set to 0 (zero) by the Nordson melter.

Page 46: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card40

Part 1054600_06 E 2015 Nordson Corporation

Indexed Packet Examples

Example 1Master action: enable melter (turn heaters on)

NOTE: In this example, the Nordson melter is operating and there are nofaults.

Transmit packetMelter control Command Data

IndexChannelNumber

Write Data Value ofChannel Number 1 2 3 4

Bit 0 set to 1:01 hex

Does not matter

Receive packet

Status Acknowledge:Data index

Acknowledge:Channel Number

Read Data Value of Channel Number+ 1 + 2 + 3 + 4 + 5

001 hex Does not matter

Example 2Master action:S Enable melterS Set temperature setpoint of Hose 1 to 150C

NOTE: In this example, the Nordson melter is operating and there are nofaults.

Transmit packetMelter control Command Data

IndexChannelNumber

Write Data Value ofChannel Number 1 2 3 4

Bit 0 set to 1:01 hex

6 hex 73 hex 3 hex 96 hex (150 _C) Does not matter

Receive packetStatus Acknowledge:

Data indexAcknowledge:

Channel NumberRead Data Value of Channel Number

+ 1 + 2 + 3 + 4 + 50001 hex 73 hex 3 hex Does not matter

Page 47: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 41

Part 1054600_06E 2015 Nordson Corporation

Example 3Master action:S Enable melterS All pumps ONS Read actual value of temperature channels 3 and 4

Result: channel 3 = 175C; channel 4 = 180C

NOTE: In this example, the Nordson melter is operating and there are nofaults.

Transmit packetMelter control Command Data

IndexChannelNumber

Write Data Value ofChannel Number 1 2 3 4

Bit 0 and bit 1 setto 1: 03 hex

3 hex 78 hex 3 hex Does not matter Does not matter

Receive packetStatus Acknowledge:

Data indexAcknowledge:

Channel NumberRead Data Value of Channel Number

+ 1 + 2 + 3 + 4 + 50001 hex 78 hex 3 hex

AF hex(175 _C)

B4 hex(180 _C) Does not matter

Page 48: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card42

Part 1054600_06 E 2015 Nordson Corporation

Full Map Data InterfaceThe full map method allows access to all melter data in one packet. Thismethod causes the packets to be much larger than that of the IndexedProtocol but requires less programming on the master side to create aninterface.

Full Map Packet ProcessingNOTE: Full map data packets are available only with melter firmware version1.114 or higher.S The master formulates a command by determining the transmission data

packet. The Nordson melter processes the command and formulates thereply packets.

S The master processes the data or repeats the command until a reply isreceived from the Nordson melter. Only one command is processed at atime. The Nordson melter keeps the reply available until the masterformulates a new command.

S When a Transmit data packet contains an error, the Nordson melterreplies with a fault bit in the Status. The master recognizes by this signalwhether the previously transmitted command was correctly processed bythe Nordson melter.

Page 49: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 43

Part 1054600_06E 2015 Nordson Corporation

Transmit and Receive PacketsThe master sends a transmission packet to the Nordson melter. This packetcontains information that the Nordson melter is to process.

The following illustration shows an example of the reading of the full map.

Mastertransmit packet

Nordson melter

Field bus system

Controlsystemwith fieldbus master

Figure 6 Example of master-to-melter communication

The Nordson melter replies to each packet from the master with statusinformation on packet processing.

Masterreceive packet

Nordson melter

Controlsystemwith fieldbus master

Fieldbus

Figure 7 Example of melter-to-master communication

The master may not formulate and transmit a new packet until after arrival ofthe receive packet.

Page 50: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card44

Part 1054600_06 E 2015 Nordson Corporation

Full Map Packet DataNOTE: Full map data packets are available only with melter firmware version1.114 or higher.S Communication is done with two data packets: Receive and Transmit

(from the master's viewpoint).S The Receive and Transmit data packets are instances 101 and 151

respectively.S The data packets always have the same length: 248 words.S The Melter Control byte is located at offset 0 of the Transmit instanceS The Status word is located at offset 0 of the Receive instance.S All available melter data can be read and written (if writable) per the Blue

Ethernet Data List.NOTE: The master may need to swap bytes in some or all of the packet dataif the data formats of the master and the Nordson melter do not correspond.

Page 51: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 45

Part 1054600_06E 2015 Nordson Corporation

Melter ControlThe melter control data in the transmit packet is executed by the Nordsonmelter with each packet.

NOTE: Unused or reserved bits must be set to 0 (zero).

Table 9 Melter Control DataBit Value Action Note0 1 Heaters ON Heaters ON and

temperature standbyrequire a transitionfrom 0 to 1 foractivation.

0 Heaters OFF

1 1 All pumps ON0 All pumps OFF

2 1 Pump 1 ON0 Pump 1 OFF

3 1 Pump 2 ON(if available)

0 Pump 2 OFF(if available)

4 1 Pump 3 ON(if available)

0 Pump 3 OFF(if available)

5 1 Pump 4 ON(if available)

0 Pump 4 OFF(if available)

6 1 Temperaturestandby ON

Heaters ON andtemperature standbyrequire a transitionfrom 0 to 1 foractivation.

0 Temperaturestandby OFF

7 1 Auto Motor ON Automatically turnsmotors on when unithas reached Ready

0 Auto Motor OFF

Page 52: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card46

Part 1054600_06 E 2015 Nordson Corporation

StatusThe status data in each receive packet communicates general informationfrom the Nordson melter.

Table 10 Status DataBit Value Action0 1 Ready for operation

0 Not ready for operation1 1 Pump Startup Protection On

0 Pump Startup Protection Off2 1 Alert

0 No alert3 1 Fault

0 No fault4 1 Shutdown

0 No shutdown5 1 Heat-up phase active

0 Heat-up phase not active6 1 Temperature standby on

0 Temperature standby off7 1 Pump 1 is running

0 Pump 1 is not running8 1 Pump 2 is running (if available)

0 Pump 2 is not running (if available)

Page 53: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 47

Part 1054600_06E 2015 Nordson Corporation

Table 10 Status Data (contd)Bit Value Action9 1 Pump 3 is running (if available)

0 Pump 3 is not running (if available)10 1 Pump 4 is running (if available)

0 Pump 4 is not running (if available)11 1 Not used

0 Not used12 - Reserved13 - Reserved14 1 Communication fault:

S Wrong command receivedS Wrong data index receivedS Wrong channel number received

0 No communication faults in packet header15 1 Communication fault in data value:

S Data values can not be changed.Example:Write command on actualvalues.

S Data access not permitted.Example:Write command in theLocal mode or commands forchannels that are not installed.

S At least one data value is invalid. Thedata packet received may not beevaluated by the master.Example: A value is outside of thepermitted value range.

0 No communication faults in data values

NOTE: Nordson melters are equipped with automatic Pump StartupProtection. The Pump Startup Protection prevents all stopped pumps (suchas those stopped as a result of an RTD fault) from starting up automaticallyafter finishing the heat-up phase or after a fault has occurred.To acknowledge the Pump Startup Protection, change the All PumpsON/OFF parameter from OFF to ON. (For a rising transition-based reset,refer toMelter Control. If bit1 = 0, then set to 1; if bit1 = 1, then set to 0 andsubsequently to 1 again.)

Page 54: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card48

Part 1054600_06 E 2015 Nordson Corporation

Master ProceduresThese procedures apply to programming executed from the master.

Master: Determine Transmit Packet1. Setmelter control.2. Change the data as desired.3. Send the transmit packet to the Nordson melter.

Melter: Process a New Packet1. Evaluate and executemelter control.2. Set map data3. Set status.4. Provide the receive packet to the master.

Master: Evaluate the Receive Packet1. Evaluate status.2. Check acknowledge data.

Page 55: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 49

Part 1054600_06E 2015 Nordson Corporation

Channel Number ListTable 11 Channel Numbers

Number Channel1 Tank2 Manifold/Pump3 Hose 14 Gun 15 Hose 26 Gun 27 Hose 38 Gun 39 Hose 410 Gun 411 Hose 512 Gun 513 Hose 614 Gun 615 Hose 716 Gun 717 Hose 818 Gun 8

Page 56: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card50

Part 1054600_06 E 2015 Nordson Corporation

This page intentionally left blank.

Page 57: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 51

Part 1054600_06E 2015 Nordson Corporation

Blue

Ethe

rnet

Data

List Gene

ralM

elter

Data

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Rema

rks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Melte

rcon

trol/stat

us1

0-FFF

FN/A

Read

/Write

NANA

0So

ftware

versi

on1

byte

1-ve

rsion

byte

0-rev

ision

N/A

Read

only

30

2

Melte

rope

ration

mode

:-L

ocalmo

de-F

ieldb

usmo

de1

1(Lo

calm

ode)

0(Fie

ldbu

s)0(

Field

bus)

Read

/Write

atthe

opera

torpa

nel

Read

onlyvia

fieldb

us4

04

Hour

Meter

:Tota

lhou

rswith

heate

rson

10-

9999

9hN/A

Read

only

50

5

Servi

ceInt

erval:

Adjus

tabletim

efram

etoc

heck

apart

icular

maint

enan

ce1

0-87

36h

(1ye

ar)50

0hRe

ad/W

rite6

06

Clea

rFau

lt/Warn

ing

NOTE

:Ifthe

fault/w

arning

cond

itionh

asno

tbee

nfixe

d,the

fault/w

arning

willrea

ppea

r.

10/1

0(no

reset)

Read

/Write

70

7

Read

ydela

yvalu

e1

0-60

min

0min

Read

/Write

90

9Au

toPu

mpOn

Off

Thisallow

sthe

unitto

autom

atica

llytur

nthe

piston

pump

onwh

enthe

unitr

each

esse

tpoint

.

10/1

1Re

ad/W

rite29

021

5

Page 58: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card52

Part 1054600_06 E 2015 Nordson Corporation

Gene

ralM

elter

Data

(contd

)

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Rema

rks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Melte

rstat

us:

-hea

tupph

ase

-star

tupprote

ction

-rea

dyfor

opera

tion

-warn

ing-fa

ult-s

hutdo

wn-s

tandb

y-m

elter

note

nable

d-m

otors

note

nable

d

10(

)1(

heatu

ppha

se)

2(sta

rtup

prote

ction

)3(

melte

rrea

dy)

4(wa

rning

)5(

fault)

6(sh

utdow

n)7(

stand

by)

8(me

ltern

oten

abled

)11

(moto

rsno

ten

abled

)

N/A

Read

only

100

10

Seco

ndsL

eftinInt

erloc

kCa

pability

tolet

theus

erse

eho

wma

nyse

cond

sare

leftin

therea

dyint

erloc

kdela

y.

10-

3600

N/A

Read

only

110

11

Hours

UntilNe

xtSe

rvice

10-

8736

N/A

Read

only

120

12Cu

rrent

alarm

High

byte:

Chan

nelN

umbe

rofth

einv

olved

chan

nel(ifth

ereisa

tempe

rature

failur

e)1-1

8(1=

Tank

2=Ma

nifold

/Pum

p,3=

Hose

1,4=

Gun1

,etc)

ORSy

stem

Failure

Numb

er(if

there

isas

ystem

failur

e):Co

nsult

your

Manu

alLo

wby

te:Bit0

:System

alarm

Bit1

:Cha

nnelala

rmBit3

:Pres

sure

alarm

Bit4

:Tan

kLev

elala

rm

100

00/FF

FFRe

adon

ly23

014

Melte

rstat

usan

dalar

msBit1

:Hos

tCom

munic

ation

Fault

Bit3

:Serv

iceRe

mind

erBit1

1:Ta

nkLo

w

100

00/FF

FFN/A

Read

only

150

15

Page 59: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 53

Part 1054600_06E 2015 Nordson Corporation

Flow/Pressure

Data

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ionDe

fault

Remarks

Flow

andP

ress

ure

Inde

xedP

rotoco

lFu

llMap

Offse

tDa

taInde

xCh

anne

lNu

mber

Pres

sure

Actua

lValu

e1-16

34.47

3-34

4.73

bar

500-5

000P

SI34

47-3

4473

kPa

N/A

Read

only

611-3

2N/A

Unde

rpres

sure

Warn

ingVa

lue1-16

0-10

0%20

Read

/Write

701-1

6N/A

Overp

ressu

reWarn

ingVa

lue1-16

0-10

0%20

Read

/Write

731-1

6N/A

Motor

Mode

1-4

0=Ma

nual

1=Ru

nup

2=Pres

sure

3=Flo

w

0Re

ad/W

rite31

1-422

0-223

Motor

Setpo

int1-4

0-10

0%0

Read

/Write

321-4

73-76

Targe

tLine

spee

dPt.2

/Sca

leFa

ctor

Lines

peed

1-16

/1-4

0-10

0%10

0Re

ad/W

rite33

1-16

/1-4

N/A

Scale

Facto

rMoto

rSpe

ed1-4

1-94R

PM94

Read

/Write

341-4

N/A

Motor

Actua

lSpe

ed1-16

RPM

N/A

Read

only

361-4

N/A

Targe

tLine

spee

dPt.1

1-16

0-10

0%0

Read

/Write

391-1

6N/A

Overp

ressu

reFa

ultVa

lue1-16

0-10

0%50

Read

/Write

761-1

6N/A

Targe

tPres

sure

Pt.2

1-16

0-10

00PS

I0-

68.9

bar

0-68

94.7

kPa

500

Read

/Write

801-1

6N/A

Targe

tPres

sure

Pt.1

1-16

0-100

0PSI

0-68

.9ba

r0-

6894

.7kP

a

100

Read

/Write

811-1

6N/A

Pres

sure

Build

Enab

le1-16

0/10

Read

/Write

821-1

6N/A

Stop

Spee

dThre

shold

1-4

0-10

0%10

Read

/Write

831-4

N/A

Pres

sure

Build

Setpo

int1-16

0-10

00PS

I0-

68.9

bar

0-68

94.7

kPa

50Re

ad/W

rite84

1-16

N/A

True

FlowLin

espe

edSe

tpoint

1-8

0-10

0%10

0Re

ad/W

rite90

1-8N/A

Page 60: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card54

Part 1054600_06 E 2015 Nordson Corporation

Flow/

Pres

sure

Data

(contd

)

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ionDe

fault

Remarks

Flow

andP

ress

ure

Inde

xedP

rotoco

lFu

llMap

Offse

tDa

taInde

xCh

anne

lNu

mber

True

FlowFlo

wSe

tpoint

1-8

1000

-500

,000

mg/m

in20

000

Read

/Write

961-8

N/A

True

FlowFlo

wStatu

s1-8

Bit0

:Warn

ingBit1

:Fau

ltN/A

Read

only

101

1-8N/A

True

FlowUn

derflo

wWarn

ing1-8

0-10

0%10

Read

/Write

102

1-8N/A

True

FlowUn

derflo

wFa

ult1-8

0-10

0%25

Read

/Write

103

1-8N/A

True

FlowOv

erflow

Warn

ing1-8

0-10

0%10

Read

/Write

104

1-8N/A

True

FlowOv

erflow

Fault

1-8

0-10

0%25

Read

/Write

105

1-8N/A

True

FlowAc

tualF

low1-8

0-50

0,000

mg/m

m10

Read

only

106

1-8N/A

Lines

peed

perce

nt1-4

0-10

0%N/A

Read

only

107

1-4N/A

Flow/Pressure

Alarm

s

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Rema

rks

Flow

andPr

essu

reInde

xedP

rotoco

lFu

llMap

Offse

tDa

taInde

xCh

anne

lNu

mber

Pres

sure

Statu

sand

Alarm

sBit0

:Und

erpres

sure

Bit1

:Ove

rpres

sure

1-16

N/A

N/A

Read

only

791-16

N/A

Page 61: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 55

Part 1054600_06E 2015 Nordson Corporation

Seve

n-Da

yCloc

kData

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Remarks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Seve

n-Da

yCloc

kswitch

edON

/OF

F,for

field

bus

10/1

0(OF

F)Re

ad/W

rite20

00

19

Statu

s:Se

ven-D

ayCloc

kin

opera

tion

10/1

N/A

Read

only

201

020

SetC

lockD

ay1

1-7

N/A

Read

/Write

202

021

SetC

lockH

our

10-

23N/A

Read

/Write

203

022

SetC

lockM

inute

10-

59N/A

Read

/Write

204

023

Comm

ands

forF

illFe

atures

Data

Desig

natio

nQu

antity

Rang

eRes

olutio

nDe

fault

Rema

rks

Inde

xedPr

otoc

olFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Tank

FillC

omma

nds

10(

Noco

mman

d)1(

Refill

on)

2(Ca

librat

eemp

ty)4(

Silen

ceala

rm)

8(Re

setre

fillfau

lt)

0Re

ad/W

rite19

60

120

Page 62: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card56

Part 1054600_06 E 2015 Nordson Corporation

PMLD

ata

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Remarks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Curre

ntMo

de:

0Ma

nual,

1Au

tomati

c1

0/10

Read

Only

205

025

Curre

ntState

:PM

L_UN

DEFIN

ED0

PML_

OFF=

1PM

L_ST

OPPE

D=2

PML_

STAR

TING=3

PML_

READ

Y=4

PML_

STAN

DBY=5

PML_

PROD

UCING=6

PML_

STOP

PING

=7PM

L_AB

ORTIN

G=8

PML_

ABOR

TED=9

PML_

HOLD

ING=1

0PM

L_HE

LD=1

1

10-11

0Re

ad/W

rite-N

ote:S

etting

this

value

toan

ything

other

than0

will

caus

ethe

melte

rtobe

have

acco

rding

tothe

PackML

spec

ificati

on.L

eave

thisv

aluea

t0ifP

ackM

Lspe

cifica

tionisn

otbe

ingus

ed.

206

026

Curre

ntState

Time

1HH

HH:M

M:SS

.hhN/A

Read

only

207

027

Curre

ntMo

deTim

e1

HHHH

:MM:

SS.hh

N/A

Read

only

208

030

OffT

ime

1HH

HH:M

M:SS

.hhN/A

Read

only

209

033

Stop

pedT

ime

1HH

HH:M

M:SS

.hhN/A

Read

only

210

036

Start

edTim

e1

HHHH

:MM:

SS.hh

N/A

Read

only

211

039

Read

yTim

e1

HHHH

:MM:

SS.hh

N/A

Read

only

212

042

Page 63: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card 57

Part 1054600_06E 2015 Nordson Corporation

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ion

Default

Remarks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Stan

dbyT

ime

1HH

HH:M

M:SS

.hhN/A

Read

only

213

045

Prod

ucing

Time

1HH

HH:M

M:SS

.hhN/A

Read

only

214

048

Stop

pingT

ime

1HH

HH:M

M:SS

.hhN/A

Read

only

215

051

Abortin

gTim

e1

HHHH

:MM:

SS.hh

N/A

Read

only

215

054

Aborted

Time

1HH

HH:M

M:SS

.hhN/A

Read

only

217

057

Holding

Time

1HH

HH:M

M:SS

.hhN/A

Read

only

218

060

Held

Time

1HH

HH:M

M:SS

.hhN/A

Read

only

219

063

Manu

alMo

deTim

e1

HHHH

:MM:

SS.hh

N/A

Read

only

220

066

Autom

aticM

odeT

ime

1HH

HH:M

M:SS

.hhN/A

Read

only

221

069

Clea

rPML

Regis

ters

10/1

0Re

ad/W

rite22

20

72

Temp

eratureD

ata

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ionDe

fault

Remarks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Temp

eratur

eunit

:Ce

lsius

/Fahre

nheit

10(_C)

/1(_F

)0_Ce

lsius

)Re

ad/W

rite11

00

139

Activate

Hose

/Gun

pair

1-80/1

0Re

ad/W

rite11

21-8

140-1

47Te

mpera

tures

etpoin

tvalu

e1-1

840

-230_C/

100-45

0_F

N/A

Read

/Write

115

1-18

149-1

66

Page 64: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15

Ethernet/IP Fieldbus Interface Card58

Part 1054600_06 E 2015 Nordson Corporation

Temp

eratureD

ata

(contd

)

Data

Desig

natio

nQu

antity

Rang

eRe

solut

ionDe

fault

Remarks

Inde

xedP

rotoco

lFu

llMap

WordO

ffset

Data

Inde

xCh

anne

lNu

mber

Temp

eratur

esetp

ointvalu

e,glo

bal

140

-230_C/

100-45

0_F

N/A

Read

/Write

116

016

7

Temp

eratur

esetp

ointvalu

e,gro

upho

se1

40-230_C/

100-45

0_F

N/A

Read

/Write

117

016

8

Temp

eratur

esetp

ointvalu

e,gro

upgu

n1

40-230_C/

100-45

0_F

N/A

Read

/Write

118

016

9

Temp

eratur

eactu

alva

lue1-1

840

-230_C/

100-45

0_F

N/A

Read

only

120

1-18

171-1

88

Activate

Temp

eratur

eCha

nnel

1-16

0/10

Read

/Write

111

1-16

N/A

Temp

eratur

estan

dbyv

alue,

globa

l1

5-190_C

10-350_F

50_C/10

0_F

Read

/Write

128

018

9

Timep

eriod

forde

activati

nghe

aters

(after

autom

atics

tandb

y)1

0-144

0min

(24h)

0min

Read

/Write

133

019

0

Timep

eriod

forau

tomati

cstan

dby

mode

activati

on(if

nogu

nsare

active)

10-

1440

min

(24h)

0min

Read

/Write

135

019

3

Unde

rtemp

eratur

efau

ltvalu

e,glo

bal

15-6

0_C/

10-110_F

0min

Read

/Write

142

019

4

Overt

empe

rature

faultv

alue,

globa

l1

5-60_

C/10

-110_F

15_C/25

_F

Read

/Write

152

019

5

Field

busd

ata:T

empe

rature

status

anda

larms

Bit0

:Hea

terisON

/OFF

Bit1

:Und

ertem

perat

urewa

rning

Bit2

:Und

ertem

perat

urefau

ltBit3

:Ove

rtemp

eratur

ewarn

ingBit4

:Ove

rtemp

eratur

efau

ltBit5

:Ove

rtemp

eratur

eshu

tdown

Bit6

:Sho

rtedt

empe

rature

sens

orBit7

:Broke

ntem

perat

urese

nsor

1-18

0000

/FFFF

(0/1)

N/A

Read

only

157

1-18

196-2

13

Auto

ExitS

tandb

y1

0-18

0min

0Re

ad/W

rite16

00

216

Page 65: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15
Page 66: Ethernet/IP Fieldbus Interface Cardemanuals.nordson.com/adhesives/English_Manuals/1054600.pdfEthernet/IP Fieldbus Interface Card Customer Product Manual Part 1054600_06 Issued 08/15