furnaces and dryers
for ceramic, porcelain
and glass fi ring
LAC kat06 -keramika A 1 4.2.2007, 12:54:05
P R O F I L E O F L A CLAC Ltd. with its registered offi ce in Rajhrad near Brno has been for 15 years successfully dealing in manufacture of fur-naces and dryers for numerous technological applications such as:
mechanical engineering • foundries • electro technical industry • plastic and rubber industry • custom-made hardening shops • research • laboratories • stoma-tology • jewel-making • ceramic industry • educa-tion • glass industry • art ceramic • china production
Production range of LAC Ltd. for domestic and foreign markets does not consist of a complex line or serial-made furnaces and dryers only, but it meets also requirements in the area of non-typical design of furnaces according to the customers‘ specifi c requirements
Dynamic development of the company is illustrated by the current number 250 employees, registered capital of 12 mil-lion CZK, 25 000 m2 of production, storage and administrative premises and 8,000 furnaces manufactured to date.
In our sales department we are ready to meet your require-ments and provide qualifi ed advice on selection of the most suitable furnace for any application. Our own team of service engineers providing maintenance of our products is a matter of course.
Besides main products we off er also supply of heating ele-ments, refractory and insulation materials, control elements, refractory shaped pieces and implementation of reconstruc-tions of furnaces, heating systems and switchboards.
LAC Ltd., Štefánikova 116, 664 61 Rajhrad, Czech Republicphone +420 547 230 016, fax +420 547 230 212
[email protected] • www.lac.cz
plant Hrušovany u Brna registered offi ce in Rajhrad plant Hrušovany n. Jevišovkou
LAC kat06 -keramika A 2 4.2.2007, 12:57:19
3
S U M M A R YI CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING
AND GLASS HEAT TREATMENT 1. Furnaces K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Furnaces KH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. Furnaces KC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4. Enameling Furnaces L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5. Furnaces PK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 6. Bogie-hearth Chamber Furnaces VKT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0 7. Bogie-hearth Chamber Furnaces VKK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1
II CIRCULAR FURNACES FOR CERAMICS AND DECORATIONS FIRING 8. Furnaces M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2
III FURNACE FOR GLASS MELTING 11. Glass Melting Furnaces TSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3
IV FURNACES FOR GLASSFUSING, BENDING, SINKING AND GLASS COOLING 9. Furnace for glassfusing with solid table GF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4 10. Furnace for glassfusing with traveling table GFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5
V FURNACES AND DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYINGAND HEAT TREATMENT
12. Dryers S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6 13. Dryers SV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7 14. Dryers SVK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8 15. Chamber Horizontal Furnaces KNC/H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 9 16. Chamber Vertical Furnaces KNC/V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 0 17. Bogie-heart Chamber Furnaces VKNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 17. Tempering Furnaces PP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2
VI SPECIAL FURNACES FOR CERAMIC AND GLASS TREATMENT 19. Gradient Furnaces SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 20. High-temperature Furnaces VP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4
VII ATYPICAL PROJECTS 21. Chamber Gas Furnace KP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5 22. Bogie-hearth Gas Chamber Furnace VKP 5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5 23. Tunnel Electric Chamber Furnace PPR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5
VIII MACHINES AND ACCESSORIES FOR CERAMIC, PORCELAIN AND GLASS PRODUCTIONS 23. Dry Spraying Box SBS and Water Screen Spraying Box SBVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6 23. Rolling table VS and Potter’s wheel HK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 21. Ball Mills MKP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 8 22. Ball Mills MKL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 9
IX FIRING AIDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 9
X MEASUREMENT AND REGULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 0
LAC kat06 -keramika A 3 4.2.2007, 12:57:30
K 120
K 500
APPLICATIONThese furnaces are suitable for ceramic and glass technologies with special intention on temperature growth and decline. Also on exactness of temperature distribution with controlled cooling. Furnaces are usable especially for decorative and industrial ceramic and porcelain fi ring, glass pan tempering, glass aftercooling, heating, aftercooling for stress elimination, decor fi ring, glass fritting and production of plastic melting’s.
FURNACES K
STANDARD DESIGN Manual door opening to the left CERAMIC controller Limit unit Ventilation of external jacket– preventing from vapour– lowering jacket temperature Ventilation fl ue for models K 50–K 300 Manual controlled ventilation fl apfor models K 500–K 2000 Aeration fl ue in the furnace bottom Stand for K 50–K 300 Optimal temperature distribution infurnace according DIN 17052-1 Bottom covered with SiC plates
LAC kat06 -keramika A 4 4.2.2007, 13:05:29
5CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
ACCESSORIES FOR EXTRA CHARGE Automatic ventilation fl ap Manual controlled fl apfor furnace K 50–K 300 Door opening to the right Overpressure cooling system Graphic temperature recorder Controller INDUSTRY Exhaust fan RS 232 or RS 485 interface for connection of controller to PC Regulation of connection to PC including software Multi-zone control system „MASTER-SLAVE“ Software for monitoring and record of temperature cycle Heated ceiling Atypical dimensions and designs according request
FURNACES KType LAC t max
°CInternalVolume l
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
K 50/12 1200 50 910 × 1405 × 1070 350 × 350 × 400 3,5 125 230
K 70/12 1200 80 910 × 1465 × 1070 350 × 450 × 450 6,5 165 400
K 120/12 1280 120 1010 × 1535 × 1140 450 × 530 × 500 9 230 400
K 150/12 1280 150 1010 × 1620 × 1160 450 × 600 × 530 10,5 280 400
K 200/12 1280 200 1060 × 1800 × 1185 500 × 750 × 530 15 310 400
K 250/12 1280 230 1090 × 1800 × 1230 520 × 800 × 550 17 360 400
K 300/12 1280 310 1105 × 1820 × 1340 560 × 800 × 710 20 420 400
K 500/12 1280 490 1460 × 1825 × 1460 650 × 1000 × 750 30 700 400
K 700/12 1280 730 1550 × 1925 × 1610 750 × 1100 × 900 45 920 400
K 1000/12 1280 1000 1570 × 2120 × 1775 800 × 1200 × 1000 55 2100 400
K 1500/12 1280 1540 1800 × 2300 × 2050 950 × 1350 × 1200 75 2600 400
K 2000/12 1280 2100 2150 × 2500 × 2450 1000 × 1500 × 1400 105 2900 400
K 120/14 1400 120 1010 × 1535 × 1140 450 × 530 × 500 10,5 230 400
K 150/14 1400 150 1010 × 1620 × 1160 450 × 600 × 530 15 280 400
K 200/14 1400 200 1060 × 1800 × 1185 500 × 750 × 530 20 310 400
K 250/14 1400 230 1090 × 1800 × 1230 520 × 800 × 550 23 360 400
K 300/14 1400 310 1105 × 1820 × 1340 560 × 800 × 710 27 420 400
K 500/14 1400 490 1460 × 1825 × 1460 650 × 1000 × 750 40 700 400
K 700/14 1400 730 1550 × 1925 × 1610 750 × 1100 × 900 60 920 400
K 1000/14 1400 1000 1570 × 2120 × 1775 800 × 1200 × 1000 75 2100 400
K 1500/14 1400 1540 1800 × 2300 × 2050 950 × 1350 × 1200 110 2600 400
K 2000/14 1400 2100 2150 × 2500 × 2450 1000 × 1500 × 1400 130 2900 400
K 50/13 1300 50 910 × 1405 × 1070 350 × 350 × 400 5,5 125 400
K 70/13 1300 80 910 × 1465 × 1070 350 × 450 × 450 7,5 165 400
K 120/13 1340 120 1010 × 1535 × 1140 450 × 530 × 500 10,5 260 400
K 150/13 1340 150 1010 × 1620 × 1160 450 × 600 × 530 15 320 400
K 200/13 1340 200 1060 × 1800 × 1185 500 × 750 × 530 20 360 400
K 250/13 1340 230 1090 × 1800 × 1230 520 × 800 × 550 23 420 400
K 300/13 1340 310 1105 × 1820 × 1340 560 × 800 × 710 27 480 400
K 500/13 1340 490 1460 × 1825 × 1460 650 × 1000 × 750 40 770 400
K 700/13 1340 730 1550 × 1925 × 1610 750 × 1100 × 900 60 990 400
K 1000/13 1340 1000 1570 × 2120 × 1775 800 × 1200 × 1000 75 2300 400
K 1500/13 1340 1540 1800 × 2300 × 2050 950 × 1350 × 1200 110 2950 400
K 2000/13 1340 2100 2150 × 2500 × 2450 1000 × 1500 × 1400 130 3300 400
Technical changes reserved
LAC kat06 -keramika A 5 6.2.2007, 10:21:26
6 CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
FURNACES KH
STANDARD DESIGN Manual door opening to the left Manual ventilation fl ap in the bottom Airing fl ue in the furnace ceiling Ventilation of external jacket– preventing from vapour– lowering jacket temperature Heating coils placed inside of lining grooves Door with secure switch CERAMIC controller Optimal temperature distribution in furnace according DIN 17052-1 SiC cover plate on furnace bottom Stand Internal package
ACCESSORIES FOR EXTRA CHARGE Automatic ventilation fl ap Manual fl ap Door opening to the right Atypical stand Controller INDUSTRY with RS 232 or EIA 485 interface Software for temperature cycle recordand monitoring Graphic temperature recorder
APPLICATIONThese furnaces are suitable for ceramic and glass technologies with special intention on temperature growth and decline, for optimal temperature distribution with controlled cooling. They are usable especially for ceramic fi ring in workshops, glass aftercooling, heating, aftercooling system for stress elimination, decor fi ring, polishing, glass fritting and production of plastic melting’s.
* With stand. Technical changes reserved
Type LAC t max°C
InternalVolume l
External Dimension(w × h* × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
KH 50/11 1100 80 715 × 1365 × 870 350 × 350 × 346 3,5 95 230
KH 90/12 1280 90 840 × 1400 × 900 450 × 410 × 505 7 125 400
KH 120/12 1280 120 840 × 1450 × 955 450 × 500 × 550 9 165 400
KH 190/12 1280 190 970 × 1580 × 955 550 × 590 × 550 12 230 400
LAC kat06 -keramika A 6 4.2.2007, 13:17:10
7CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
STANDARD DESIGN Controller CERAMIC SiC cover plate on furnace bottom Stand Ventilation of external jacket– preventing from vapour– lowering jacket temperature Top insulation materials– low power consumption– rapid approach to required
temperature Heating from 5 sides, includingthe bottom Optimal temperature distributionin furnace according DIN 17052-1 Door with secure switch Manual door opening to the left The lifespan of spirals is limitedin 1400 °C models
ACCESSORIES FOR EXTRA CHARGE Graphic temperature recorder Manual fl ap Automatic fl ap Manual door opening to the right Controller INDUSTRY RS 232 or RS 485 interface for connect the controller to PC Atypical stand Software for record and monitoringof temperature cycle Overpressure cooling system Reinforced of input
FURNACES KCAPPLICATIONThese furnaces are suitable mostly for ceramic, glass and other laboratories tests. It is applicable for fast fi ring and optimal tempera-ture distribution to control increase and decline of temperature. Eventually for control of cooling where it is possible to separate heat elements in the internal space of furnace. They are usable especially for fastfi ring tests of art and industrial ceramics, porcelains, enam-els, glass aftercooling, heating and aftercooling for stress elimination, decorates fi ring, glass fritting, polishing and melting plastics production.
* External dimension including stand. Technical changes reserved
Type LAC t max°C
InternalVolume l
External* Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
KC 20/13 1300 20 760 × 1250 × 850 270 × 270 × 270 8 160 400
KC 40/13 1300 40 945 × 1470 × 1020 350 × 350 × 350 9 170 400
KC 80/13 1300 80 985 × 1540 × 1070 430 × 430 × 430 12 280 400
KC 120/13 1300 120 1080 × 1480 × 1120 500 × 500 × 500 15 350 400
KC 20/14 1400 20 760 × 1250 × 850 270 × 270 × 270 9 160 400
KC 40/14 1400 40 945 × 1470 × 1020 350 × 350 × 350 11 170 400
KC 80/14 1400 80 985 × 1540 × 1070 430 × 430 × 430 13 280 400
KC 120/14 1400 120 1080 × 1480 × 1120 500 × 500 × 500 18 350 400
LAC kat06 -keramika A 7 4.2.2007, 13:24:31
8 CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
STANDARD DESIGN One-hand door opening downwards HT 40A controller Stainless steel design Ventilation of external jacket– preventing from vapour– lowering jacket temperature Airing fl ue at the back of the furnace
Top insulation materials– low power consumption– rapid approach to required temperature Optimal temperature distribution in furnace accordingDIN 17052-1 Sheet ceramic muffl e assembled of refractory material which prohibit charge and heating spirals contact
APPLICATIONThese furnaces are suitable for ceramic and glass laboratories for fast fi ring and optimal temperature distribution to control increase and decline of temperature. Eventually for control of cooling where it is possible to separate heat elements in furnace chamber. They are usable especially for fast fi ring tests of art and industrial ceramics, glass aftercooling, heating, aftercooling for stress elimination, decors fi ring, glass fritting, polishing etc.
ACCESSORIES FOR EXTRA CHARGE Graphic temperature recorder INDUSTRY controller RS 232 or RS 485 interface for connect the controller to PC Exhaust fan Inlet of protection atmosphere Software for record and monitoring of temperature cycle
Technical changes reserved
FURNACES L
Type LAC Controller t max°C
Volumel
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
L 03/12 HT 40A 1200 3 380 × 440 × 400 180 × 100 × 140 1,2 21 230
L 05/12 HT 40A 1200 5 430 × 470 × 430 230 × 130 × 170 2,4 26 230
L 09/12 HT 40A 1200 9 430 × 505 × 500 230 × 170 × 240 3,0 32 230
L 15/12 HT 40A 1200 15 450 × 505 × 600 250 × 170 × 340 3,5 39 230
LAC kat06 -keramika A 8 4.2.2007, 13:29:59
9CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
PK 17/12 – 230 V
* Types for 230 V have slower temperature heat curve that why are suitable only for laboratory works. Technical changes reserved
TypeLAC
t max°C
Volumel
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
PK 10/12 1280 10 700 × 700 × 790 230 × 200 × 350 3 60 230
PK 10/12R 1280 10 700 × 700 × 790 230 × 200 × 350 5,5 70 400
PK 17/12 1280 17 720 × 700 × 790 250 × 200 × 350 3,5 80 230
PK 17/12R 1280 17 1050 × 1430 × 1700 250 × 200 × 350 7,25 230 400
PK 25/12 1280 25 1050 × 1440 × 1700 250 × 250 × 400 11 250 400
PK 35/12 1280 40 1100 × 1440 × 1900 290 × 250 × 550 11 320 400
PK 55/12 1280 55 1180 × 1440 × 1900 400 × 250 × 550 13 450 400
PK 75/12 1280 75 1180 × 1440 × 2100 400 × 250 × 750 18 510 400
PK 105/12 1280 105 1300 × 1350 × 1900 500 × 350 × 600 21 660 400
PK 130/12 1280 130 1300 × 1500 × 2000 500 × 350 × 750 21 750 400
PK 180/12 1280 180 1350 × 1950 × 2000 550 × 400 × 800 29 830 400
PK 225/12 1280 225 1400 × 2150 × 2050 600 × 500 × 750 29 920 400
PK 350/12 1280 350 1500 × 2150 × 2400 700 × 450 × 1100 50 1100 400
PK 540/12 1280 540 1500 × 2450 × 3000 600 × 600 × 1500 50 1540 400
PK 680/12 1280 680 2200 × 2600 × 2450 900 × 500 × 1500 70 1620 400
PK 1000/12 1280 1000 2100 × 2750 × 2850 900 × 600 × 1800 70 1980 400
PK 1400/12 1280 1400 2300 × 2750 × 3200 1100 × 600 × 2100 95 2500 400
FURNACES PKAPPLICATIONThese furnaces are suitable for all glass technologies where a very precise temperature distribution and dynamic progress of temperature curve are required. Especially for hardening, artifi cial ageing, curing, heat treatment, heating before forging, preheating of glass forms etc.
STANDARD DESIGN PK 10/12 and PK 17/12 has insulation of insulation fi re bricks and mineral fi bre From types PK 17/12R the stressed parts of lining made of refractory concrete– high resistance– long life
Heating on sides and on the bottom Optimal distribution of temperature in furnace according DIN 17052-1 Door opening
– downwards using springs for PK 10/12and PK 17/12
– downwards using counterweight for PK 17/12(R) to PK 75/12
– upwards using counterweight for PK 105/12 to PK 540/12
– upwards using hydraulic cylinders for PK 680/12 to PK 1400/12
Turning table for charge handling fromPK 105/12 to PK 540/12 Stand Programmable PID controller INDUSTRY
ACCESORIES FOR EXTRA CHARGE Semi-gas tide design of the furnace Protection atmosphere inlet Metal plate on furnace bottom SiC side cover plates to protect spirals Pneumatic manual (push button) or foot pedal door control Graphic temperature recorder Connection of controller to PC Non-typical internal dimensions Non-typical stand RS 232 or RS 485 interface for connect the controller to PC Semi-gas metal retort with atmosphereprotection supply Overpressure ventilation
LAC kat06 -keramika A 9 4.2.2007, 13:33:58
10 CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
VKT 7000
APPLICATIONThese furnaces are suitable for all glass technologies where a very precise temperature distribution and dynamic progress of tempera-ture curve are required with managed cooling system using opening of furnace on temperature. Especially for preheating of glass forms, cooling for stress reliving, glazing, decor fi ring and glass fusing etc. The bogie, which simultaneously makes the bottom of the furnace is suitable for heavy and high volume charges using crane.
FURNACES VKT
Technical changes reserved
STANDARD DESIGN For max. temperature 1260 °C Door opening upwards using hydraulic cylinders Tiller contact stop Heating placed on four walls of the furnaceand in the bogie Optimal distribution of temperature in furnaceaccording DIN 17052-1 Separate switchboard from VKT 5000 Manually-driven bogie Electrically-driven bogie from VKT 3000 Bogie spirals covered with SiC plates Manual controlled ventilating fl ap Programmable PID controller INDUSTRY Limit unit HT 40B Controller a control in switchboard Rails
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder Second bogie manually or electrically driven Electrically driven bogie for furnaces of volume 800 and 2000 l RS 232 or RS 485 interface for connect the controller to PC Metal plates on working surface of the bogie up to temperature of 1000 °C 3 ammeters Overpressure cooling system Automatic ventilating fl ap Multi zone regulation system „MASTER-SLAVE“ Software for record and monitoring temperature cycle Second door
Type LAC t max°C
InternalVolume l
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
VKT 800/09 900 800 2350 × 2650 × 2500 900 × 600 × 1500 32 1300 400
VKT 1000/09 900 1000 2350 × 2650 × 3050 900 × 600 × 2000 40 1500 400
VKT 1500/09 900 1500 2450 × 2500 × 3500 1000 × 600 × 2500 60 2300 400
VKT 2000/09 900 2000 2250 × 2900 × 3500 1000 × 800 × 2500 80 2800 400
VKT 3000/09 900 3000 2650 × 3250 × 4000 1000 × 1000 × 3000 110 3500 400
VKT 5000/09 900 5000 2700 × 4500 × 4050 1200 × 1400 × 3000 130 4200 400
VKT 7000/09 900 6700 2700 × 4500 × 5050 1200 × 1400 × 4000 150 4900 400
VKT 800/12 1260 800 2350 × 2650 × 2500 900 × 600 × 1500 40 1300 400
VKT 1000/12 1260 1000 2350 × 2650 × 3050 900 × 600 × 2000 60 1500 400
VKT 1500/12 1260 1500 2450 × 2500 × 3500 1000 × 600 × 2500 80 2300 400
VKT 2000/12 1260 2000 2250 × 2900 × 3500 1000 × 800 × 2500 110 2800 400
VKT 3000/12 1260 3000 2650 × 3250 × 4000 1000 × 1000 × 3000 130 3600 400
VKT 5000/12 1260 5000 2700 × 4500 × 4050 1200 × 1400 × 3000 180 4300 400
VKT 7000/12 1260 6700 2700 × 4500 × 5050 1200 × 1400 × 4000 250 5000 400
LAC kat06 -keramika A 10 4.2.2007, 13:40:42
11CHAMBER FURNACES FOR PORCELAINS, ENAMELS, DECORATIVES, CERAMICS FIRING AND GLASS HEAT TREATMENT
VKK 1500
FURNACES VKK
Technical changes reserved
Type LAC t max°C
InternalVolume l
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
VKK 1000/12 1280 1170 2250 × 2000 × 2350 1000 × 900 × 1300 45 1500 400
VKK 1500/12 1280 1500 2250 × 2100 × 2550 1000 × 1000 × 1500 70 1800 400
VKK 2000/12 1280 2000 2250 × 2100 × 3100 1000 × 1000 × 2000 95 2200 400
VKK 3000/12 1280 3025 2400 × 2200 × 3600 1100 × 1100 × 2500 130 2500 400
VKK 5000/12 1280 5080 2400 × 2500 × 4400 1100 × 1400 × 3300 160 3200 400
VKK 7000/12 1280 7084 2400 × 2500 × 5800 1100 × 1400 × 4600 195 4000 400
VKK 1000/13 1340 1170 2250 × 2000 × 2350 1000 × 900 × 1300 65 1500 400
VKK 1500/13 1340 1500 2250 × 2100 × 2550 1000 × 1000 × 1500 95 1800 400
VKK 2000/13 1340 2000 2250 × 2100 × 3100 1000 × 1000 × 2000 115 2200 400
VKK 3000/13 1340 3025 2400 × 2200 × 3600 1100 × 1100 × 2500 160 2500 400
VKK 5000/13 1340 5080 2400 × 2500 × 4400 1100 × 1400 × 3300 200 3200 400
VKK 7000/13 1340 7084 2400 × 2500 × 5800 1100 × 1400 × 4600 265 4000 400
STANDARD DESIGN INDUSTRY controller Limit unit HT 40B Optimal temperature distribution in furnace accordingDIN 17052-1 Door opening sideward Tiller contact stop
Heated bogie Manual ventilation fl ap Ventilation of external jacket– preventing from vapour– lowering jacket temperature Rails
APPLICATIONThese furnaces are suitable for all ceramic and glass technologies where a very precise temperature distribution and dynamic progress of temperature curve are required, for controlled cooling with limited change of opening the furnace on temperature. They are usable especially for art and industrial ceramic fi ring, glass pan tempering, glass aftercooling, heating, aftercooling for stress elimination, decor fi ring, polishing, glass fritting and production of plastic melting’s.
ACCESSORIES FOR EXTRA CHARGE Graphic temperature recorder Automatic door opening upwards Exhaust fan Second bogie manual or electrically driven Electrically driven bogie from volume 800–1500 l Metal plates on working surface of the bogie up to temperature of 1000 °C 3 ammeters Overpressure cooling system Automatic ventilation fl ap Multi-zone control system MASTER-SLAVE Refractory bricks lining RS 232 or RS 485 interface for connect the controller to PC Software for record and monitoring temperature cycle Second door Combustor with draft damper
LAC kat06 -keramika A 11 4.2.2007, 13:44:27
12 CIRCULAR FURNACES FOR CERAMICS AND DECORATIONS FIRING
M 200
APPLICATIONParticularly for „hobby“ ceramists but also for professional fi ring of ceramic and glass products requiring upper loading.
STANDARD DESIGN CERAMIC or HT 40A controller Cover plug for ventilation hole Optimal temperature distribution in furnace according DIN 17052-1 Jacket made of polished stainless steel sheet Stable lid suspension Handrail on furnace sides
ACCESSORIES FOR EXTRA CHARGE Interlaced sheets Spacers 20–300 mm
FURNACES M
* Without controller. Technical changes reserved
Type LAC t max°C
InternalVolume l
External Dimension(∅ * × v) mm
Internal Dimension(∅ × v) mm
InputkW
Weightkg
Controller VoltageV
M 30/12 1280 30 570 × 600 350 × 345 3,5 65 Ceramic 230
M 45/12 1280 45 605 × 600 410 × 345 3,5 73 Ceramic 230
M 60/12 1280 60 605 × 700 410 × 455 5,5 86 Ceramic 400
M 100/12 1280 100 750 × 670 525 × 455 7,5 122 Ceramic 400
M 125/12 1280 140 820 × 670 620 × 455 8,5 142 Ceramic 400
M 200/12 1280 200 820 × 900 620 × 685 11 185 Ceramic 400
M 30/13 1340 30 570 × 600 350 × 345 3,5 65 Ceramic 230
M 45/13 1340 45 605 × 600 410 × 345 4,0 73 Ceramic 400
M 60/13 1340 60 605 × 700 410 × 455 5,5 86 Ceramic 400
M 100/13 1340 100 750 × 670 525 × 455 7,5 122 Ceramic 400
M 125/13 1340 140 820 × 670 620 × 455 8,5 142 Ceramic 400
M 200/13 1340 200 820 × 900 620 × 685 11 185 Ceramic 400
LAC kat06 -keramika A 12 4.2.2007, 13:48:57
13FURNACE FOR GLASS MELTING
TSH 20/13
FURNACES TSHAPPLICATIONThese furnaces are suitable for production of forest blowing glass with possibility of electric heating for molten glass and afterwards heat treatment with glass pipe using of gas burner.
STANDARD DESIGN Frame made from the construction steel Isolation of mineral fi bre desks and lightweight bricks Muffl e of the SiC parts Melting bath from ceramic material HT 40B controller Adjustable steady for glass pipe Standalone steady for glass pipe Gas injector burner
Type LAC t max°C
MeltingVolume l
External Dimension(w × h × d) mm
Internal Dimension(w × h) mm
InputkW
Weightkg
VoltageV
TSH 20/13 1300 20 1300 × 1350 × 1630 270 × 300 6 500 400
Technical changes reserved
ACCESSORIES FOR EXTRA CHARGE Graphic temperature recorder INDUSTRY controller RS 232 or RS 485 interface for connect of controller to PC Software for record and monitoring of temperature cycle
LAC kat06 -keramika A 13 4.2.2007, 13:54:50
14 FURNACES FOR GLASS FUSING, BENDING, SINKING AND GLASS COOLING
GF 200/10
APPLICATIONThese furnaces are intended for production of bend and sintered glass and further glass processing using the sinking technology. They are usable also for glass aftercooling, heating and controlled cooling for stress elimination, decorative fi ring, polishing etc. De-pending on accessories and size, these furnaces are suitable both for artistic and industrial production.
STANDARD DESIGN Manual furnace opening with gas springs Heating in ceramic tubes Ventilation chimneys around the circumference CERAMIC controller Frame welded from construct steel Insulation by micro porous insulation plate and isoblocks from fi brous mat
ACCESSORIES FOR EXTRA CHARGEFOR FURNACES GF 75/09480/10
Wheels for stand INDUSTRY controller Quartz glass tubes Manual venting fl aps connected by pull bar on sides or on ceiling Automatic venting fl aps on sidesor on ceiling Graphic temperature recorder RS 232 or RS 485 interface for connectof controller to PC
ACCESSORIES FOR EXTRA CHARGE FOR FURNACES GF 560/10–1250/10
Quartz glass tubes INDUSTRY controller Automatic ventilation fl aps on sidesand on the ceiling Manual ventilation fl aps connected by pull bar on sides Graphic temperature recorder RS 232 or RS 485 interface for connect of controller to PC Heating in walls and a in the bottom Multizone control MASTER-SLAVE
Technical changes reserved
FURNACES GF
Type LAC t max°C
Volumel
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
GF 75/09 950 75 950 × 1270 × 920 500 × 350 × 500 3,6 115 230
GF 75/09/R 950 75 950 × 1270 × 920 500 × 350 × 500 5,5 115 400*
GF 200/10 1000 200 1480 × 1350 × 920 1000 × 400 × 500 8 195 400
GF 340/10 1000 340 1480 × 1450 × 1300 1000 × 400 × 850 12 300 400
GF 480/10 1000 480 1700 × 1450 × 1500 1200 × 400 × 1000 18 360 400
GF 560/10 1000 560 2150 × 1450 × 1300 1650 × 400 × 850 20 390 400
GF 760/10 1000 760 2150 × 1450 × 1650 1650 × 400 × 1150 22 590 400
GF 920/10 1000 920 2500 × 1450 × 1650 2000 × 400 × 1150 24 650 400
GF 1050/10 1000 1050 2700 × 1450 × 1700 2200 × 400 × 1200 30 790 400
GF 1250/10 1000 1250 2900 × 1450 × 1900 2400 × 400 × 1300 35 860 400
LAC kat06 -keramika A 14 4.2.2007, 14:01:32
15FURNACES FOR GLASS FUSING, BENDING, SINKING AND GLASS COOLING
GF 350/10
APPLICATIONThese furnaces are intended for production of bend and sintered glass and further glass processing using the sinking technology. They are usable also for glass aftercooling, heating and controlled cooling for stress elimination, decorative fi ring, polishing etc. De-pending on accessories and size, these furnaces are suitable both for artistic and industrial production.
FURNACES GFS
Type LAC t max°C
Volumel
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
GFS 480/09 950 480 1800 × 1450 × 1500 1200 × 400 × 1000 18 440 400
GFS 560/09 950 560 2250 × 1450 × 1300 1650 × 400 × 850 20 470 400
GFS 760/09 950 760 2250 × 1450 × 1650 1650 × 400 × 1150 22 720 400
GFS 920/09 950 920 2600 × 1450 × 1650 2000 × 400 × 1150 24 780 400
GFS1050/09 950 1050 2800 × 1450 × 1700 2200 × 400 × 1200 30 870 400
GFS1250/09 950 1250 3000 × 1450 × 1900 2400 × 400 × 1300 35 940 400
GFS 1500/09 950 1470 3200 × 1600 × 2100 2450 × 400 × 1500 43 2400 400
GFS 1800/09 950 1813 3200 × 1600 × 2500 2450 × 400 × 1850 45 2400 400
GFS 2640/09 950 2640 3800 × 1600 × 2900 3000 × 400 × 2200 70 3200 400
GFS 3000/09 950 3080 4300 × 1600 × 2900 3500 × 400 × 2200 75 3700 400
Technical changes reserved
STANDARD DESIGN Manual opening of furnace with gas springs (models GFS 480–GFS 1250)
Elektrohydraulic upward opening of furnace (models GFS1500–3000)
Heating placed in ceramic tubes Ventilation chimneys around circumference CERAMIC controller Limit unit Stand Traveling table
ACCESSORIES FOR EXTRA CHARGE Quartz glass tubes INDUSTRY controller Manual ventilation fl aps connected bypull bar on sides Automatic ventilation fl aps on sides oron the ceiling Graphic temperature recorder RS 232 or RS 485 interface for connectof controller to PC Software for record and monitoring temperature cycle Heating in walls and in the bottom Multizone control MASTER-SLAVE(for GF 560/10–GF1250/10) Another bogie Bogie drive Trackage with transfer for relocationof bogies Overpressure cooling system
LAC kat06 -keramika A 15 4.2.2007, 14:08:23
16 DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
S 400
DRYERS S
STANDARD DESIGN For max. temperature 200 °C and 300 °C Muffl e assembled of stainless steel Air circulation using circulation fans(for models S 60 and S 100) Circulation using central circulation units(for models S 250 to S 1000) Adjusting shelves Horizontal air circulation Optimal heat distribution in dryer according DIN 17052-1 Circulation insert– optimal distribution of air circulation Manually controlled ventilation fl ap Door opening to the left on hinges Stand (for models S 60 to S 400) Programmable PID controller INDUSTRY
ACCESORIES FOR EXTRA CHARGE Automatically controlled ventilation fl ap Additional shelves Exhaust fan One-hand door opening Traveling wheels Hydraulic door opening upwards for models S 60 to S 650 Manual door opening to the right Possibility of second door for model S 1000 Relative humidity measurement Gas analyzer METREX Graphic temperature recorder Connection of controller to PC Non-typical design of dryer or stand Door window Inside light Pressurized cooling Alarm device
APPLICATIONThese dryers are suitable for plastic, rubber, automotive, electro technical, glass and foundry industry, especially for drying, vulcaniza-tion, preheating and curing, for drying and curing of surface layers and modifi cations of various materials etc.
Technical changes reserved
Type LAC t max°C
Volumel
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
InputkW
Number offans pcs
Number ofshelves pcs
Weightkg
S 60/02 200 60 1050 × 1350 × 950 450 × 300 × 450 2 1 1 60
S 100/02 200 100 1050 × 1550 × 1000 450 × 500 × 450 3 2 1 100
S 250/02 200 240 1400 × 1550 × 1200 800 × 500 × 600 4 1 2 250
S 400/02 200 380 1400 × 1750 × 1200 800 × 800 × 600 4 1 2 350
S 650/02 200 640 1700 × 1350 × 1400 1000 × 800 × 800 6 1 2 480
S 1000/02 200 960 1700 × 1750 × 1400 1000 × 1200 × 800 9 2 3 650
S 60/03 300 60 1050 × 1350 × 950 450 × 300 × 450 3 1 1 60
S 100/03 300 100 1050 × 1550 × 1000 450 × 500 × 450 3 2 1 100
S 250/03 300 240 1400 × 1550 × 1200 800 × 500 × 600 4 1 2 250
S 400/03 300 380 1400 × 1750 × 1200 800 × 800 × 600 6 1 2 350
S 650/03 300 640 1700 × 1350 × 1400 1000 × 800 × 800 8 1 2 480
S 1000/03 300 960 1700 × 1750 × 1400 1000 × 1200 × 800 12 2 3 650
LAC kat06 -keramika A 16 4.2.2007, 14:12:42
17DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
SV 1500/25
DRYERS SV
Technical changes reserved
APPLICATIONThese dryers are suitable for plastic, rubber, automotive, electro technical, glass and foundry industry, especially for drying, vulcanization, preheating and curing, for drying and curing of surface layers and modifi cations of various materials etc.
Optimal heat distribution in dryer according DIN 17052-1 Circulation insert– optimal distribution of air
circulation Exhaust chimney with manually controlled fl ap
Double wing door with handles and opens to the side Programmable PID controller INDUSTRY 3 ammeters Limit unit is thermo regulator
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder Automatic ventilating fl ap Exhaust fan for outlet RS 232 or RS 485 interface for connect the controller to PC Relative humidity measurement Loading frame with shelves according the request Charging bogie with shelves according the request Door window Gas analyzer METREX Hydraulic door opening upwards Software for record and monitoring of temperature cycle Pressurized ventilation Adjustment for vertical air circulation in dryer Second door Adjustment of bottom for charging bogie Dryer power reduction or increase Indirect gas heating Alarm device
STANDARD DESIGN For max. temperature 250 and 450 °C Muffl e assembled of stainless steel Horizontal circulation usingcentral fan on back sideof dryer
Type LAC t max°C
Volumel
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
InputkW
Weight kg
VoltageV
SV 1500/25 250 1500 1800 × 2400 × 2100 1000 × 1800 × 800 18 900 400
SV 3300/25 250 3300 2000 × 2500 × 2850 1100 × 2000 × 1500 24 1400 400
SV 4000/25 250 4190 2100 × 2500 × 2950 1200 × 2000 × 1600 30 1550 400
SV 4500/25 250 4560 2900 × 1700 × 3200 2000 × 1200 × 1900 36 1600 400
SV 6000/25 250 6000 2850 × 2500 × 3200 2000 × 1500 × 2000 58 1750 400
SV 8000/25 250 8000 2850 × 3000 × 3200 2000 × 2000 × 2000 75 1900 400
SV 18500/03L 250 18500 3850 × 3100 × 4200 3000 × 2050 × 3000 50 2650 400
SV 1500/45 450 1500 1800 × 2400 × 2100 1000 × 1800 × 800 30 900 400
SV 3300/45 450 3300 2000 × 2500 × 2850 1100 × 2000 × 1500 42 1400 400
SV 4000/45 450 4190 2100 × 2500 × 2950 1200 × 2000 × 1600 55 1550 400
SV 4500/45 450 4560 2900 × 1700 × 3200 2000 × 1200 × 1900 60 1600 400
SV 6000/45 450 6000 2850 × 2500 × 3200 2000 × 1500 × 2000 85 1750 400
SV 8000/45 450 8000 2850 × 3000 × 3200 2000 × 2000 × 2000 105 1900 400
SV 18500/45L 450 18500 3850 × 3100 × 4200 3000 × 2050 × 3000 80 2650 400
LAC kat06 -keramika A 17 4.2.2007, 14:18:34
18 DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
Atyp SVK 3600
DRYERS SVK
Technical changes reserved
APPLICATIONThese dryers are suitable for plastic, rubber, automotive, electro technical, glass and foundry industry. Thanks to its design they provide for comfortable loading of bulky and heavy batches into the furnace using a crane or other method. Especially for drying, vulcanization, curing of surface layers, granulates drying, burning-in of electrical components and preheating of various materials before additional processing and further for heat treatment of material such as artifi cial ageing of aluminium and its alloys and other materials
STANDARD DESIGN For max. temperature 250 and 450 °C Muffl e assembled of stainless steel Vertical circulation using central fan on the furnaces ceiling Optimal heat distribution in dryer accordingDIN 17052-1 Circulation insert– optimal distribution of air circulation Manually controlled ventilating fl ap Hydraulic door opening upwards Dryer bogie including gear– manual drive for SVK 1000–SVK 2000– electrical drive for SVK 3600–SVK 7200 Frame of bogie is made of steel forfi le Bottom of the bogie is made of steel metal Programmable PID controller INDUSTRY 3 ammeters Rails Limit unit HT 40B
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder Second manually or electrically-driven bogie RS 232 or EIA 485 interface for connect the controller to PC Automatic ventilating fl ap Software for record and monitoring of temperature cycle Second door Relative humidity measurement Gas analyzer METREX Alarm device Furnace power reduction or increase Indirect gas heating Exhaust fan
Type LAC t max°C
Volumel
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
VoltageV
InputkW
Weightkg
SVK 1000/25 250 1020 1600 × 2400 × 1650 900 × 900 × 1260 400 30 1106
SVK 1500/25 250 1500 1800 × 2500 × 1900 1000 × 1000 × 1500 400 45 1258
SVK 2000/25 250 2000 1800 × 2500 × 2400 1000 × 1000 × 2000 400 55 1390
SVK 3600/25 250 3600 2100 × 2900 × 2900 1200 × 1200 × 2500 400 65 1690
SVK 4500/25 250 4330 2100 × 2900 × 3400 1200 × 1200 × 3000 400 70 1790
SVK 7200/25 250 7200 2400 × 3600 × 3400 1500 × 1600 × 3000 400 85 2695
SVK 1000/45 450 1020 1600 × 2400 × 1650 900 × 900 × 1260 400 38 1133
SVK 1500/45 450 1500 1800 × 2500 × 1900 1000 × 1000 × 1500 400 50 1288
SVK 2000/45 450 2000 1800 × 2500 × 2400 1000 × 1000 × 2000 400 65 1417
SVK 3600/45 450 3600 2100 × 2900 × 2900 1200 × 1200 × 2500 400 75 1724
SVK 4500/45 450 4300 2100 × 2900 × 3400 1200 × 1200 × 3000 400 80 1817
SVK 7200/45 450 7200 2400 × 3600 × 3400 1500 × 1600 × 3000 400 95 2789
LAC kat06 -keramika A 18 4.2.2007, 14:25:04
19FURNACES AND DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
KNC/H 1000
FURNACES KNC/H
STANDARD DESIGN For max. temperature 650 °C and 850 °C Circulation insert of stainless steel or refractory material– optimal distribution of air circulation Loading sill height of the furnace is 500 mm Heating meanders on ceramic holders Door opening upwards using hydraulic cylinders Horizontal air circulation Optimal heat distribution according to DIN 17052-1 Insulation with mineral fi bre isoblocks Programmable PID controller INDUSTRY Controller and regulator in the switch board on the right side Limit unit HT 40B
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder Grids with own legs RS 232 or RS 485 interface for connect the controller to PC 3 ammeters Software for record and monitoring of temperature cycle Non-typical dimension design on request Manually controlled ventilating fl ap Automatic ventilating fl ap
APPLICATIONThese furnaces are suitable for glass technology where a very precise temperature distribution and dynamic progress of temperature curve are required. Especially for tempering, artifi cial ageing, preheating heat treatment, hot connecting, batch testing, drying, etc.
Technical changes reserved
Type LAC t maxoC
Internal volume l
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
KNC/H 1000/65 650 1000 2300 × 3200 × 2100 1000 × 1000 × 1000 36 1300 400
KNC/H 1500/65 650 1500 2800 × 3200 × 2100 1500 × 1000 × 1000 48 1500 400
KNC/H 2000/65 650 2000 3400 × 3200 × 2100 2000 × 1000 × 1000 72 1750 400
KNC/H 1000/85 850 1000 2400 × 3300 × 2200 1000 × 1000 × 1000 42 1300 400
KNC/H 1500/85 850 1500 2900 × 3300 × 2200 1500 × 1000 × 1000 54 1500 400
KNC/H 2000/85 850 2000 3500 × 3300 × 2200 2000 × 1000 × 1000 80 1750 400
LAC kat06 -keramika A 19 4.2.2007, 14:29:33
20 FURNACES AND DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
KNC/V 730
KNC/V 290
FURNACES KNC/V
STANDARD DESIGN For max. temperature 650 °C and 850 °C Circulation insert of stainless steel or refractory material – optimal distribution of air circulation Heating meanders on ceramic holders Lid opening backwards using pneumatic cylinders Horizontal air circulation Optimal heat distribution according to DIN 17052-1 Insulation with mineral fi bre isoblocks Programmable PID controller INDUSTRY Controller and regulator in desk switch board Limit unit HT 40B
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder RS 232 or RS 485 interface for connect the controller to PC 3 ammeters Software for record of temperature cycle Non-typical internal dimension Manually controlled ventilating fl ap Automatic ventilating fl ap
APPLICATIONThese furnaces are suitable for glass technology where a very precise temperature distribution and dynamic progress of temperature curve are required. Especially for tempering, artifi cial ageing, preheating heat treatment, hot connecting, batch testing, drying, etc.
Technical changes reserved
Type LAC t max°C
Internalvolume l
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
InputkW
Weightkg
VoltageV
KNC/V 270 650 270 1600 × 1200 × 2300 700 × 650 × 600 18 360 400
KNC/V 540 650 540 1800 × 1300 × 2500 900 × 750 × 800 24 600 400
KNC/V 1000 650 1000 1700 × 1600 × 2700 1000 × 1000 × 1000 36 890 400
KNC/V 1500 650 1500 2200 × 1600 × 2700 1500 × 1000 × 1000 60 1240 400
KNC/V 2000 650 2000 2700 × 1600 × 2700 2000 × 1000 × 1000 75 1750 400
KNC/V 270 850 270 1700 × 1300 × 2400 700 × 650 × 600 24 380 400
KNC/V 540 850 540 1900 × 1400 × 2600 900 × 750 × 800 36 630 400
KNC/V 1000 850 1000 1800 × 1700 × 2800 1000 × 1000 × 1000 48 930 400
KNC/V 1500 850 1500 2300 × 1700 × 2800 1500 × 1000 × 1000 64 1290 400
KNC/V 2000 850 2000 2800 × 1700 × 2800 2000 × 1000 × 1000 90 1830 400
LAC kat06 -keramika A 20 4.2.2007, 14:35:37
21FURNACES AND DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
VKNC 1000
FURNACES VKNC
STANDARD DESIGN For max. temperature 650 °C and 850 °C Door opening upwards using hydraulic cylinders Circulation insert of stainless steel or refractory material– optimal distribution of air circulation Vertical air circulation Optimal distribution of temperature according DIN 17052-1 Heat meanders on ceramic holders Manually driven bogie for VKNC 1000 and 1500 Electrically driven bogie from type VKNC 2000 Manually controlled ventilating fl ap Insulation with mineral fi ber isoblocks Programmable PID controller INDUSTRY Limit unit HT 40B Controller and control in switchboard on right side Rails
ACCESORIES FOR EXTRA CHARGE Graphic temperature recorder Electrically or manually driven bogie for furnacesof volume 1000 and 1500 l Second bogie manually or electrically driven RS 232 or RS 485 interface for connectthe controller to PC 3 ammeters Automatic ventilating fl ap Software for record and monitoringof temperature cycle Second door Non-typical internal dimension
Technical changes reserved
APPLICATIONThese furnaces are suitable for all glass technology where a very precise temperature distribution and dynamic progress of temperature curve are required. Especially for tempering, artifi cial ageing, preheating heat treatment, hot connecting, batch testing, drying, etc. Thanks, the bogie, which made the bottom of the furnace, is suitable for heavy and high volume charges using crane.
Type LAC t max°C
Volumel
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
InputkW
VoltageV
Weightkg
VKNC 1000/65 650 1000 2200 × 3200 × 1800 900 × 900 × 1260 42 400 1450
VKNC 1500/65 650 1500 2300 × 3300 × 2100 1000 × 1000 × 1500 54 400 1600
VKNC 2000/65 650 2000 2300 × 3300 × 2600 1000 × 1000 × 2000 74 400 1950
VKNC 3600/65 650 3600 2500 × 3500 × 3100 1200 × 1200 × 2500 87 400 2400
VKNC 5500/85 650 5240 2600 × 3600 × 3700 1300 × 1300 × 3100 95 400 4800
VKNC 7200/65 650 7200 2800 × 3900 × 3800 1500 × 1600 × 3000 110 400 5500
VKNC 1000/85 850 1000 2300 × 3300 × 1900 900 × 900 × 1260 45 400 1500
VKNC 1500/85 850 1500 2400 × 3400 × 2200 1000 × 1000 × 1500 60 400 1650
VKNC 2000/85 850 2000 2400 × 3400 × 2700 1000 × 1000 × 2000 80 400 2100
VKNC 3600/85 850 3600 2600 × 3600 × 3200 1200 × 1200 × 2500 95 400 2550
VKNC 5500/85 850 5240 2700 × 3700 × 3800 1300 × 1300 × 3100 150 400 4950
VKNC 7200/85 850 7200 2900 × 4000 × 3900 1500 × 1600 × 3000 160 400 5600
LAC kat06 -keramika A 21 4.2.2007, 14:39:58
22 FURNACES AND DRYERS WITH INTERNAL AIR CIRCULATION FOR DRYING AND HEAT TREATMENT
PP 40/45
Technical changes reserved
STANDARD DESIGN� For max. temperature 650 °C and 850 °C� External jacket from crimped sheet� Muffl e assembled of stainless refractory
steel� Circulation insert
– optimal distribution of air circulation� Horizontal air circulation� Optimal temperature distribution
according DIN 17052-1� Manually controlled ventilating fl ap� Fibre insulation
– low operational costs� Stand (except of type PP 20)� Programmable PID controller INDUSTRY� Limit unit
ACCESORIES FOR EXTRA CHARGE� Semi-gastight design of the furnace� Protection atmosphere inlet
(component set)� Automatically controlled ventilating fl ap� One-hand door opening� Door opening to the left or upwards� Graphic temperature recorder� Connection of controller to PC� Non-typical design of furnaces or stand� Automatic overpressure cooling� Additional shelves� Software for record and monitoring
of temperature cycle
APPLICATIONThese furnaces are suitable for all technologies where a very precise temperature distribution and dynamic progress of temperature curve are required. Especially for tempering, artifi cial ageing, curing, heat treatment, glass tempering, heating and after cooling to glass stress elimination, ceramic fi ring, glazing and glass fritting etc.
TEMPERING FURNACES PP
Type LAC t max°C
Volumel
External dimension(w × h × d) mm
Internal dimension(w × h × d) mm
Shelvespcs
HeatingInput kW
Weightkg
VoltageV
PP 20/65 650 20 800 × 650 × 1050 300 × 200 × 350 - 3 115 230
PP 40/65 650 35 900 × 1450 × 1050 300 × 300 × 400 2 6 160 400
PP 70/65 650 70 950 × 1550 × 1150 350 × 400 × 500 2 8 200 400
PP 20/85 850 20 800 × 650 × 1050 300 × 200 × 350 - 3,3 115 230
PP 40/85 850 35 900 × 1450 × 1050 300 × 300 × 400 2 7 160 400
PP 70/85 850 70 950 × 1550 × 1150 350 × 400 × 500 2 9 200 400
23SPECIAL FURNACES FOR CERAMIC AND GLASS TREATMENT
SP 30/13
FURNACES SP
Technical changes reserved
Type LAC t max°C
Volumel
External Dimension(w × h × d) mm
Internal Dimension(w × h) mm
InputkW
Weightkg
VoltageV
SP 30/13 1300 30 1700 × 1200 × 500 1400 × 140 7 240 400
APPLICATIONThese furnaces are suitable for acceleration of all tests mostly in industrial, ceramic, glass and others laboratories. The temperature fall enables to insert more samples and check their afterfi re structure in furnace. They are usable especially for fritting tests, calcinations, softening and sintering point setting, ceramics and enamels fi ring tests.
STANDARD DESIGN� Driving zone controlled by the controller INDUSTRY, next 4 zones measured by the
thermocouples connected to the display CAL� Top insulation materials
– low power consumption– rapid approach to required temperature
� Manually opened lid with handrails� Lid insulation of the mineral grain� Insulation created by the sedge of the mineral grain
ACCESSORIES FOR EXTRA CHARGE� Multizone measurer Ht 100 (possibility of the scanning till 10 places)� RS 232 or RS 485 interface for connect of controller to PC� Software for record and monitoring temperature cycle
24 SPECIAL FURNACES FOR CERAMIC AND GLASS TREATMENT
VP 04/16
VP 20/17
FURNACES VP
STANDARD DESIGN One-hand opening sideward INDUSTRY controller Stainless steel design for VP 02 and VP 04 Jacket air cooling by fans Types VP 02 and 04 in table design Optimal temperature distribution in furnaceaccording DIN 17052-1
Top insulation materials– low power consumption– rapid approach to required temperature Door with secure switch
ACCESSORIES FOR EXTRA CHARGE Graphic temperature recorder RS 232 or RS 485 interface for connect of controller to PC Inlet of protection atmosphere Software for record and monitoring temperature cycle Exhaust fan
APPLICATIONThese furnaces are suitable for testing in scientist, research, industrial and ceramic laboratories. It is applicable for high-temperature technologies testing with impact on optimal temperature distribution. Eventually for control of cooling where it is possible to sepa-rate heat elements in the furnace chamber. They are usable especially for metal or ceramic powder materials fritting, softening and sintering point setting or for high temperature ceramic trials.
Technical changes reserved
Type LAC t max°C
InternalVolume l
External Dimension(w × h × d) mm
Internal Dimension(w × h × d) mm
MaximalInput kW
NominalInput kW
Weightkg
VoltageV
VP 02/16 1600 2 660 × 680 × 765 130 × 150 × 135 3 3 90 230
VP 04/16 1600 4 660 × 680 × 765 130 × 160 × 180 3.5 3 100 230
VP 10/16 1600 10 850 × 1595* × 775 200 × 200 × 250 9 6 290 400
VP 20/16 1600 20 850 × 1595* × 860 250 × 250 × 310 12 8 315 400
VP 70/16 1600 70 1000 × 1650 × 1070 400 × 300 × 600 18 14 350 400
VP 02/17 1700 2 660 × 680 × 765 130 × 150 × 135 3 3 90 230
VP 04/17 1700 4 660 × 680 × 765 130 × 160 × 180 3.5 3 100 230
VP 10/17 1700 10 850 × 1595* × 775 200 × 200 × 250 9 6 290 400
VP 20/17 1700 20 850 × 1595* × 860 250 × 250 × 310 12 8 315 400
VP 70/17 1700 70 1000 × 1650 × 1070 400 × 300 × 600 18 14 350 400
LAC kat06 -keramika A 24 4.2.2007, 14:55:29
25ATYPICAL PROJECTS
VKP 5000/14
PPR
Technical changes reserved
CHAMBER GAS FURNACE KPAPPLICATIONThis furnace is used particularly in ceramic industry for fi ring of ornamental and industrial ceramics and china in large quantities.
STANDARD DESIGN Frame welded from „L“ profi les with „trapezial“ sheetsfrom structural steel Hand door opening to the left Insulation by isoblocks of mineral fi bre High-speed burners Exhauster INDUSTRY controller
ACCESSORIES FOR EXTRA CHARGE Automatic atmosphere control (oxidation/reduction) Cooling system– faster furnace cooling using burners Graphic temperature recorder RS 232 or RS 485 interface for connection of the controller to PC Software for temperature cycle monitoring and record Door opening to the right
Type LAC t max°C
Internal useablevolume l
External Dimension(w × h × d)* mm
Internal usable Dimension(w × h × d) mm
InputkW
VoltageV
KP1000/14 1400 1000 2750 × 2200 × 2700 1000 × 1000 × 1000 200 400
BOGIEHEARTH CHAMBERGAS FURNACE VKP 5000
APPLICATIONBogie-hearth chamber furnace VKP is intended for industrial fi ring and production of ceramic materials and china. The whole furnace is de-signed to meet the strictest technical requirements for heat treatment of ceramic materials and the strictest regarding the safety at work with heat device. It features high reliability, resistance to perforation by rusting, low power demand and minimum maintenance demands.
TECHNICAL DATA Max. temperature: 1360 °C Internal dimension: 1500 × 1600 × 2100 mm (w × h × d) Internal useable volume: 5040 l Total internal dimension: 1700 × 2100 × 2600 mm (w × h × d) Internal volume: 9282 l External dimension including draw-off mechanism:3000 × 3000 × 4400 mm (w × h × d) Burner input: 100kW (4 pcs.) Gas input: soil gas, moderated pressure 100 kPa Lining: fi bred Weight: 4200 kg without wagon Lid for hot gases escape: automatic managed regulator Furnace wagons: 2 peaces Automatic ferry for furnace bogie
APPLICATION Furnace is intended for ceramic fi ring.
TECHNICAL DATA Max. temperature 1000 °C Electrical heating meanders Preheating zone heated by means of contra-fl ow exhausts Cooling zone Hydraulic driven furnace bogies with automatic controlled drive through the furnace Fibrous insulating materials Programmable controllers CERAMIC Total furnace length 38 m Max. input 260 kW
TUNNEL ELECTRIC CHAMBER FURNACE PPR
LAC kat06 -keramika A 25 4.2.2007, 14:58:10
SBS
SBVC
DRY SPRAYING BOX SBS
SPRAYER BOX WITHWATER SCREEN SBVC
APPLICATIONIt is suitable for application of glazes or engobes on ceramic products by spraying. Produced dust particles are exhausted through fi lter into exhaust fan.
STANDARD DESIGN Light with clip Stand Rotating stand ring Discharge in chamber bottom for off take of excessive glaze Simple fi lter of non-woven textile in the chamber ceiling
ACCESSORIES FOR EXTRA CHARGE Exhaust fan ∅ 160 mm Exhaust hose ∅ 160 mm Hose clip Replacement fi lter 250 × 560 mm
APPLICATIONApplication of glazes or engobes on ceramic products by spraying. Produced dust particles settle on the rear screen, over which the water fl ows, thus preventing these particles from dispersing into ambient environment.
STANDARD DESIGN Light with clip Stand Water reservoir Rotating stand ring Compensation cistern Sludge pump
ACCESSORIES FOR EXTRA CHARGE Exhaust fan ∅ 160 mm Exhaust hose ∅ 160 mm Hose clip QIP 180 Replacement fi lter 250 × 560 mm
* Without exhaust fan. Technical changes reserved
** With exhaust fan.
* Without exhaust fan. Technical changes reserved
** With exhaust fan.
Type LAC External Dimension(w × h × d) mm
Internal Dimension (w × h × d) mm
InputW
Weightkg
VoltageV
SBS 750 × 1750* × 880 650 × 660 × 500 60* 150** 65 230
Type LAC External Dimension(w × h × d) mm
Internal Dimension (w × h × d) mm
InputW
Weightkg
VoltageV
SBVC 750 × 1750* × 880 650 × 615 × 540 150* 250** 65 230
LAC kat06 -keramika A 26 4.2.2007, 15:04:25
27MACHINES AND ACCESSORIES FOR CERAMIC, PORCELAIN AND GLASS PRODUCTIONS
HK
VS
SLAB ROLLER VS
APPLICATIONThe potter’s wheel with using above all to the production of the turning ceramics e.g. vases, plates bowls, cup and others products, where with must reach even the oval recontouring. Subsequently with on produce can by the help of the scribing tools create diff erent variety of graven motives and the shapes. It is necessary to use above all the ceramic earth, which is more plastic and serves above all for the production of the ceramic products made on the potters wheel.
STANDARD DESIGN Frame made of structural steel Bottom plate of antiskid ribbed sheet of structural steel Engine cover of structural steel Upholstery seat, horizontally and vertically adjustable Working surface of the wheel consists plastic moulding with a tub and hob Twisting wheel of diameter 250 mm Potters wheel working is provided by a 230 V or 400 V Power supply switch Rotation-direction switch Spin starting pedal Breaking pedal
ACCESSORIES FOR EXTRA CHARGE Turntable of diameter 300 mm Gauge Wheeling arm
APPLICATIONThis roller is suitable for manufacture of ceramics of plates.
STANDARD DESIGN Frame made of structural steel Working surface consists of fi nished chipboard late Guiding bars in the inside, on which a chain or gear wheel is located and surfaces for guiding wheels Traveling cylinder over the working surface is controlled in horizontal direction by wheel, in vertical direction by two cranks setting the thickness of the layer to be rolled Plastic plate with the same dimension as the working surface
ACCESSORIES FOR EXTRA CHARGE Wimple
POTTER’S WHEEL HK
Technical changes reserved
Technical changes reserved
Type LAC External Dimension(w × h × d) mm
Weightkg
VS 850 × 1150 × 1000 60
Type LAC External Dimension(w × h × l) mm
Revolution/min
Weightkg
InputW
VoltageV
HK 230V 700 × 830 × 1050 230 95 550 230
HK 400V 700 × 830 × 1050 230 95 550 400
LAC kat06 -keramika A 27 4.2.2007, 15:09:06
28 MACHINES AND ACCESSORIES FOR CERAMIC, PORCELAIN AND GLASS PRODUCTIONS
MKP 100
APPLICATIONThey are suitable for grinding and homogenization of ceramic material, grog, raw material, glazes, dying agents and admixtures only in wet condition with excellent results.
STANDARD DESIGN Frame made from „U“ profi les of structural steel Frame drive Internal surface of grinding roller plated with special elastomer– extreme reduction of noise– lower electricity consumption– multiplicated prolongation of lining replacement– higher operating life of the mill
ACCESSORIES FOR EXTRA CHARGE Grinding bodies Full automation
PRODUCTION BALL MILLS MKP
Technical changes reserved
Type LAC Vesseldiameter mm
External Dimension (w × h × l) mm
Revolutions/min InputkW
Max. weight ofgrinding bodies kg
VoltageV
MKP 100 500 1050 × 1600 × 900 60 2,2 86 400
MKP 300 650 1460 × 1650 × 1000 40 2,2 256 400
MKP 500 800 1600 × 1700 × 1100 35 4 430 400
MKP 1000 970 2100 × 1600 × 2000 28 5,5 860 400
MKP 2000 1200 2600 × 1750 × 2300 25 11 1720 400
MKP 3000 1400 2800 × 1900 × 2500 20 16 2580 400
LAC kat06 -keramika A 28 4.2.2007, 15:13:05
29MACHINES AND ACCESSORIES FOR CERAMIC, PORCELAIN AND GLASS PRODUCTIONS/FIRING AIDS
MKL
Technical changes reserved
APPLICATION This mill is suitable for mixing and grinding of material in both dry and wet condition with possibility to grid particles of microns dimension depending on material and time. Especially metal, ceramic or glass material grinding.
Distance poles Height of supplied standardized distance poles (mm)
MINI (∅ 26 mm) 20 30 40 50 60 70 80
MIDI (∅ 40 mm) 40 60 80 100 125 150 180 200 250
MAXI (∅ 50 mm) 40 60 80 100 125 150 180 200 250 300
INTERLAYER PLATES AND DISTANCE POLESParticularly interlayer plates are used to protect the furnace bottom or as interlayer plates for fi ring on multiple fl oors (material cordierite-mullite). Distance poles are used to build the fl oors. We can supply these aids in various standardized sizes, but also in dimensions on request. Interlaying crosses are intended for specifi c charge position.
APPLICATIONVarious fi ring aids are available for better utilisation of the furnace internal space.
Technical changes reserved
BALL MILL MKL
FIRING AIDS
STANDARD DESIGN Frame made from structural steel Grinding vessels from 1.5 liters up to 6 liters (always 2 pieces) Rubber closure lids with yokes (always 2 pcs) Ceramic grinding bodies
ACCESSORIES FOR EXTRA CHARGE
Grinding vessels from 1.5 liters up to 6 liters (always 2 pieces) Rubber closure lids with yokes (always 2 pcs) Ceramic grinding bodies
WARNINGNew and unused interlaying plates must be dried before fi rst fi ring. Temperature in furnace for this purpose should achieve 350 °C in approx. three and a half hours. After this process that will protect the plate from cracking it is possible to use the plates in a usual manner. No warranty guarantee for interlayer plates.
Volumel
Max. weight ofgrinding bodies kg
Max. weight ofground fi lling kg
1,5 1,5 0,5
5 6 2
6 8 2,5
GRINDING VESSEL WITH CLOSING YOKE
Type LAC External Dimension(w × h × l) mm
VoltageV
Revolution/min
InputkW
Weightkg
MKL 490 × 420 × 1490 230 75 0,25 70
LAC kat06 -keramika A 29 4.2.2007, 15:15:48
30 MEASUREMENT AND REGULATION
TimeManual start Automatic switch offafter dwell
Temperature [°C]
910
Automaticend of cycle
TimeManualor automatic start
8
76
5
34
2
1
Temperature [°C]
INDUSTRY
HT 40A
HT 40A temperature controller Simple operation Constant temperature control
TEMPERATURE CONTROLLERSElectrical resistance furnaces of LAC, Ltd. are fi tted with the following types of high-quality PID controllers HT 40A, INDUSTRY or CERAMIC. The said controller types are microprocessor-controlled instruments meeting all temperature control and electro-thermal device security requirements.
NDUSTRY temperature controller Simple operation Real-time clock 30 programs can be saved in the memory,each including up to 15 steps Optional control of furnace accessories– automatic ventilation fl ap– temperature progress report– signalling, etc. Temperature increase or decrease overdefi ned time
MEASUREMENT AND CONTROL
Control according to simple program Control accuracy ± 2 °C
Temperature increase or decrease at required speed in °C/hour Control accuracy ± 2 °C Optional connection to PC via RS 232 or RS 485 interface Four independent auxiliary outputs Optional fi tting with two communication lines (allowing for MASTER-SLAVE combination) Programs can be connected using JuMP step Optional modifi cation of setting parameters duringprogram run
LAC kat06 -keramika A 30 4.2.2007, 15:18:33
31MEASUREMENT AND REGULATION
910
Automaticend of cycle
TimeManualor automatic start
8
76
5
34
2
1
Temperature [°C]
CERAMIC
RS 232/
RS 485
COM 1
COM 2
PROCESS CONTROL AND MONITORING FROM PC INDUSTRY communication software Monitoring and subsequent print of displayed processes Data history MASTER-SLAVE control
SEMICONDUCTOR RELAYSSemiconductor relays with optically separated input and output, in which low input power (in orders of mW) can control high output powers (in orders of kW).
CERAMIC temperature controller Simple operation Real-time clock Optional control of furnace accessories– automatic ventilation fl ap– temperature progress report– signalling, etc.
20 programs can be saved in the memory, each including up to 15 steps Temperature increase or decrease over defi ned time Temperature increase or decrease at required speed in °C/hour Control accuracy ± 2 °C
CONTROL AND INSPECTION PANEL Device status monitoring
Inspection of supply to individual phases using ammeters
MEASUREMENT AND CONTROL
LAC kat06 -keramika A 31 4.2.2007, 15:25:09
LAC Ltd., Štefánikova 116, 664 61 RajhradCzech Republic
tel. +420 547 230 016 fax +420 547 230 212
www.lac.cz
EDITION OF LAC CATALOGUES
INDUSTRIAL FURNACES AND DRYERS
LABORATORY FURNACES
HOBBY FURNACES
UNIVERSAL CARBURISING AND HARDENING LINE
REFRACTORY
TENTO PROJEKT JE SPOLUFINANCOVÁN EVROPSKÝM FONDEM PRO REGIONÁLNÍ ROZVOJ A MINISTERSTVEM PRŮMYSLU A OBCHODU
LAC kat06 -keramika A 32 4.2.2007, 15:25:37