EPU-EX1LED Edge Lit Exit Sign E
INTRODUCTION
FEATURES
•
•
•
•
•
EPU-EX1 is LED Exit Sign for USA market, Aluminum housing combineswith acrylic panel making fixture look high profile, single or double face background optional; 6” EXIT lettering with 3/4” stroke, it can be surface and wall mounting, LED self-contained luminaire with manual test and auto test optional.
W. [email protected] E. www.epowerem.com
unit:mmDimensions
11.8''11''
7''6'' 9.8''
1.6''
3''
9.8''
Color / Background / Mounting Options
Mirror Background Ceiling/Wall MountingClear Background Side Mounting
Compact, decorative design.ELT Listed,CEC title 20 Compliance.
Suitable for single and double face applications.
Attractive - glowing red/green high-grade acrylic exit panel.
Canopy for wall/ceiling/side mounting included.
Epower Tech Co.,Ltd
Model List
EPU-EX1-S-SG/R
EPU-EX1-S-DG/R
EPU-EX1-R-SG/R
EPU-EX1-R-DG/R
EPU-EX1-S/R-SG/R
EPU-EX1-S/R-DG/R
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
24H
24H
24H
24H
90mins
90mins
90mins
90mins
Ni-Cd 3.6V900mAh Single / Double Green/Red AL / WH / BK
AL / WH / BK
AL / WH / BK
AL / WH / BK
AL / WH / BK
AL / WH / BK
Green/Red
Green/Red
Green/Red
Green/Red
Single / Double
Single / Double
Single / Double
Single / Double
Single / Double
Ni-Cd 3.6V900mAh
Ni-Cd 3.6V900mAh
Ni-Cd 3.6V900mAh
AC Only
AC Only
AT/MT
AT/MT
AT/MT
AT/MT
Model
*Surface Model: EPU-EX1-SRecessed Model: EPU-EX1-R
Input Voltage Charge Duration DischargeDuration Battery Face Letter Color Finishing Color Test Mode
9.5''6.6''6''
3.6''
11''
15''
W. [email protected] E. www.epowerem.com
unit:mmDimensionsColor / Background Options
Mirror Background Clear Background
Green/Red
Epower Tech Co.,Ltd
3.Manual Testing
NOTE:After repairing a service fault,press and hole the test button for 2 seconds to reset the flashing indicator light to red.
• Red Solid On Ready/Normal Operation
• Red Blinks Requires Service
• One flashes, 4 seconds pause Battery not connected
Low battery voltage
Charger board fault
AC/DC transfer fault
•• Two flashes, 4 seconds pause
••• Three flashes, 4 seconds pause
•••• Four flashes, 4 seconds pause
••••• Five flashes, 4 seconds pause
Instructions for automatic test option
• Every 4seconds: Checks for battery disconnection,charger board fault,lamp fault and transfer fault.
• Every month: Performs a 3minutes duration test.• Every year:Performs a 90 minutes duration test.
All test functions are factory preset and do not need field adjustment.
1.Once the unit is powered up it will antomaticlly initiate a self test and diagnostics as follows:
2.Dual Colour Indicator LED Status Mesnings
LED lamp fault
Press test button once 30 seconds duration test
3 minutes duration test
30 minutes duration test
90 minutes duration test
Press test button twice within 2 seconds
Press test button 3 times within 2 seconds
Press test button 4 times within 2 seconds
Driver Datasheet
Model EPU-EX1-S
Frequency
Discharge Efficiency
Total load wattage
Input Voltage
Output Power
Power FactorRated Input Current
Full load output voltageOutput current range
DC2.8-3.3V
1W max
280mA±10%
0.5KV
AC3750V
Surge
Withstand voltage
≥80%
2W±0.5W 2W±0.5W
120-277V
≥0.3
≤0.18A
50/60Hz
EPU-EX1-R
DC2.8-3.3V
1W max
280mA±10%
0.5KV
AC3750V
≥80%
120-277V
≥0.3
≤0.18A
50/60Hz
Technical Data SheetModel EPU-EX1-S
CCT(K)±10%
CRI
Letter Size
EPU-EX1-R
W. [email protected] E. www.epowerem.com
LED Driver
5000K
>70
6"height with 3/4" stroke
Built-in
Class I
IP20
White/Black
Aluminum +PMMA
0℃ ~45℃
0℃ ~65℃
Operating Temp (°C)
Storage Temp (°C)
5000K
>70
6‘’height with 3/4‘’ stroke
Built-in
Class I
IP20
White/Black
Aluminum +PMMA
0℃ ~45℃
0℃ ~65℃
Protection Class
IP Rating
Finishing color
Material
www.epowerem.com [email protected] TEL: +86-755 85272094