4
10 3’ DELTA RIB EPIC STEEL 3’ DELTA RIB 6574 Hwy 10 West | Missoula, MT | 406.542.1711

EPIC STEEL 3’ DELTA RIB

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EPIC STEEL 3’ DELTA RIB

10

3’ DELTA RIBE P I C S T E E L

3’ D

ELTA

RIB

6574 H w y 10 West | M issoula, MT | 406.542.1711

Page 2: EPIC STEEL 3’ DELTA RIB

3’ DELTA RIB TRIMMATERIAL SPECIFICATIONS

LOAD TABLES

3’ DELTA

RIB

11

Made in Montana - Refer to Color Chart for Color Availability

Span (ft.)

Three or More Span Condition

28 Gauge & 80 ksi

LL(S) LL(D) OUTWARD(S)

3 41.2 36.7 39.2

4 23.2 15.5 22.1

5 14.8 7.9 14.1

• 1 ½” Bearing Length• Load Span Tables Based on Working Stress• Flexural Design analysis according to AISI “Specification for the Design of

Light Gauge Cold-Formed Steel Structural Members” May 1981• Continuous Span Loading applies to sheets continuous over three or more

spans• Weight of sheet has not been allowed for when calculating live load and

Uplift.• Deflection (L/180) limiting live load based on deflection of span.• Metal thickness based on minimum ASTM specifications for allowable load

calculations• Loads may be increased by 1/3 for wind loads

Areas of discontinuity are subject to higher spikes in wind pressure, therefore a different coefficient in wind pressure will need to be considered and multiplied by a factor of 1.5

Data from: 1994 UBC Table 16-F

Note: The load tables have been compiled for the design of steel roofing and siding used in conjunction with either wood or steel framed structures. EPIC Steel assumes no responsibility, either expressed or implied, for its use.

Minimum Slope Requirement: 3:12

Screw Application: #10 Wood grip fasteners are designed for use with dimensional lumber, #14 Wood grip fasteners are designed for use with plywood sheeting, OSB, and wafer wood (7/16” minimum thickness). #12 Tek screws are designed to be used with structural steel up to 3/16” in thickness.

Roof Application: Fasteners to be applied along side every rib and attached to each purlin, 2’ on center. Please note that it is the responsibility of the builder to ensure that purlins are adequately spaced to meet specific engineering requirements.

EPIC Steel is neither partially nor solely responsible for improper installation or defects as a result of installation.

APPLICATION DETAILS

Gauge: 28, 26

Weight: 1.98 lb. /LF, 2.67lbSteel Yield Stress: 80,000 psiGalvalume Steel Gauge, AZ-50

Paint System: Stormshield Xt-40, Energy Star® Rated, Silicone Modified Polyester

Warranty: 40 Years

Available Material Type:Painted, Galvalume®

Gauging System: Epic Steel follows the national A.I.S.I. (American Iron and Steel Institute) specifications manual for tolerances in galvanized sheet metal.

All gauges conform to ASTM A792 and ASTM A653 Grade E (80,000 min. yield)/ or Grade D (50,000 min. yield) unless otherwise designated at time of order.

w w w.EPICsteelcorp.com

Page 3: EPIC STEEL 3’ DELTA RIB

SNA

P LO

CK3’ DELTA RIB STANDARD TRIM

12

3’ D

ELTA

RIB

STA

ND

ARD

TRI

M

pitch &paint

4”

4”

Endwall

3½” paint

11⁄16”3½”½”

Sidewall

½”

½”

paint

pitch

45⁄16”

1½”

Standard Ridge Cap

paint

11⁄16”

½”

½”

35⁄8”

X = 4¼”X = 6¼”

X

Gable

28 GA.(10’1” / Stick)

Eave

paint

pitch

2”

½”

XX = 3½”X = 5½”

Outside Corner

paint

11⁄16” 11⁄16”

4½” 4½”

½”¾”

Upper Transition

63⁄8”

6½”

paint

pitch

Lower Transition

63⁄8”

6½”

pitch & paint

Style-D Eave

½”

2”

3”

1”

paint

pitch

High Eave

½”

X

4¼”

X = 4¼”X = 6¼”

paint

pitch

Mini Gable

½”

11⁄16”

½”

2”

4”

paint

W-Valley

XX = 9”X = 17”X = 19.5”

X1”

paint

3¼”17⁄8”

1¼” ¾”

paint

Snow Stop

3/4” J-Metal

17⁄8”

7⁄8”

7⁄8”

½”

paint

F+J 3/4” x 3/4”

13⁄16”

¾”7⁄8”

27⁄16”

25⁄16”

19⁄16”

paint

F+J 1/2” x 3/4”

13⁄16”

½”7⁄8”

2”1½”

25⁄16”

paint

6574 H w y 10 West | M issoula, MT | 406.542.1711

Page 4: EPIC STEEL 3’ DELTA RIB

3’ DELTA RIB STANDARD TRIM

13

3’ TUF RIB

3’ DELTA

RIB STAN

DA

RD TRIM

13

28 GA.(10’1” / Stick)

Wainscott

15⁄8”

1½”7⁄8”

paint

Square Base

11⁄16”13⁄16”

13⁄16”

11⁄16”

paint

Angle Base

17⁄8”

1¾”

7⁄8”paint

L-Base / Drip Cap

1½”

½”1”

paint

28 GA.(10’1” / Stick)

Inside Corner

paint

11⁄16”

11⁄16”

4”

4”

¾”

¾”

Mini Door Jamb

55⁄8”

1½”

1”

paint

Standard Door Jamb

7½”

1½”

1”

paint

Open Jamb

paint

5½”

1½”

Double Track Cover

5½”

67⁄8”

13⁄8”

¾”

paint

Single Track Cover

5¾”

3”

1¾”

1¼”¾”

paint

w w w.EPICsteelcorp.com