Upload
anonymous-itzbhugoi
View
213
Download
0
Embed Size (px)
Citation preview
8/18/2019 EOI-101414-404 - Firewater Pumps Package
1/6
EXPRESSION OF INTEREST
White Rose Extension Project (WREP) – EOI / PrequaliicationFire!ater Pu"#s Pac$a%e
EOI&'''&
Mustang Canada Inc. is seeking prequalification responses from interested companies forprovision of the Firewater Pumps Package for use on the Husky Energy hite !ose E"tensionPro#ect. Husky Energy is currently in the planning stages for this development which$ su%#ect tofinal company$ partner and regulatory approvals$ would include construction of a ellheadPlatform &HP'.
Interested companies must %e qualified to conduct the work scope as outlined in theprequalification questionnaire.
!espondents are required to demonstrate their capa%ilities and e"perience via a formalresponse to this E(I)Prequalification advertisement. !espondents should provide a history of
operations in the *orth +tlantic &or equivalent climate'. Further details on Husky Energy and its(perating Environment are outlined %elow.
Mustang Canada Inc. strongly supports providing opportunities to Canadian, inparticular Newfoundland and Labrador companies and individuals, on acommercially competitive basis. Pre-qualied companies will be required tocomplete a Canada!Newfoundland and Labrador "enets #uestionnaire at t$e "idstage. Mustang Canada Inc. also encourages t$e participation of members of designated groups %women& 'boriginal peoples& persons wit$ disabilities& andmembers of visible minorities( and corporations or cooperatives owned by t$em, int$e supply of goods and services.
Please provide one &,' original and one &,' copy of your formal response no later than Tues*a+,No-e".er th at 01#", NST to the address as shown %elow-
Mustang Canada Inc. +ttn- Ms. aime Howard
,/ 0uffy Place Email- Procurement!EP1mustangeng.com
2t. ohn3s$ *4 Canada 5el- 6, &/78' /89:9,;,
+,< =M/
2ac$%roun*
Husky Energy has %een active on Canada3s East Coast for more than >7 years. Husky Energyis the operator of the hite !ose field and has several e"ploration prospects in the central part
of the eanne d?+rc 7 m of water$ 9A7 km eastof 2t. ohn3s$ *ewfoundland and 4a%rador$ Canada. 5he field consists of %oth oil and gaspools$ including the 2outh hite !ose oil pool. 5he oil pool covers appro"imately =7 km> andcontains an estimated >77:>A7 million %arrels of recovera%le oil.
)*I-+++- irewater Pumps Pac/age Page + of 0
8/18/2019 EOI-101414-404 - Firewater Pumps Package
2/6
+ new HP will %e situated appro"imately / km west of the e"isting 2ea!ose Floating$Production$ 2torage$ (ffloading &FP2(' vessel.
O#eratin% En-iron"ent
Husky Energy?s lease holdings on the Brand 7 compliant and shall consist of a complete packaged unit$ completewith all au"iliary equipment necessary to make it a safe and opera%le$ standaloneunit.
>' 5he Firewater Pumps shall %e of an electric su%mersi%le type with the capa%ility tomeet the following conditions-
Service Duty Qty Flow
(m3/h
r)
Dif
Head
Colum
n
Lengt
h
Inlet
Densit
y
(g/m
3)irewat
er
Cont. 1 +1
%appro
+0 m
%appro
23 m
%appro
+43
)*I-+++- irewater Pumps Pac/age Page 4 of 0
8/18/2019 EOI-101414-404 - Firewater Pumps Package
3/6
Pumps 5( 5( 5(
9' 5he Firewater Pump 0iesel Benerators will %e mounted on a skid$ which will %einstalled in an +;7 rated room$ located on the cellar deck area of the HP. 5he skidshall %e complete with all ancillary equipment$ controls and instrumentation.
=' Each package shall %e complete with$ %ut not limited to the following equipment and
requirements-
• Centrifugal$ vertical tur%ine pump c)w coarse suction strainer
• Pump discharge column riser$ head with flanged outlet noDDle and surface
mounting plate
• Mechanical 2eal
• 0iesel engine generator for su%mersi%le motor
• Motor cooling$ seal flushing and %earing lu%rication system incl. oil circulation
unit)header tank as required• +utomatic air release and vacuum %reaker valve
• CentraliDers
• Caisson chemical dosing piping and dosing ring
• Instrumentation for protection and monitoring
• Primary and 2econdary starting systems suita%le for %lack start
• >= hour diesel day tank siDed %ased on full load fuel consumption
• +ll electrical ) instrument ca%ling$ #unction %o"es$ terminals and accessories
• 2uita%le for installation in a Class I Gone > haDardous +rea and shall %e certified
per C2+ requirements.
•
Earthing %osses for the skid and earthing of individual items• Mechanical$ structural$ electrical and internal process design of equipment
• Fire suppression system &for diesel generator enclosures'
• 2preader %ars$ slings and shackles for installation of the skid using single point
lift
• Material selection in accordance with Pro#ect 2pecifications
• 0edicated com%ustion air intake with rig:saver$ separate from
ventilation)cooling air supply for enclosure.
• +ll necessary piping$ fittings and valves.
• Mounting on a structural steel skid$ with vi%ration isolating mounts.
•
First fill lu%ricants and consuma%les &
8/18/2019 EOI-101414-404 - Firewater Pumps Package
4/6
• +ll necessary FB detection devices as per Pro#ect 2pecifications &for diesel
generator enclosures'
A' Compliance with all Mustang Canada Inc. and Husky Energy pro#ect specifications
and requirements$ e"cept for mutually agreed deviations. +lso$ responsi%le for
ensuring that 2u%:vendors are capa%le of meeting all requirements and that they aresupplied with the correct technical documentation and all relevant sections of the
Purchase (rder and all su%sequent approved revisions of the relevant sections of
the !equisition document.
;' Compliance with supplier ) packager ) manufacturer %lueprints$ drawings and
specifications for all components that comprise the Firewater Pumps Package$ thus
ensuring that form$ fit and function for interchangea%le components$ systems and
su%:systems are not adversely affected.
/' 2u%mission of a comprehensive monthly progress report and critical path schedules
detailing all items in the critical path and their progress for each month. +s well asparticipation in a monthly status conference call.
@' Participation in at least one clarification meeting prior to award at the Client?s facility$
a kickoff meeting after award at the packager?s facility$ a H+G(P meeting at the
Client?s facility$ a design finaliDation meeting prior to design freeDe at the Client?s
facility$ a pre:inspection meeting at the packager?s facility$ a pre:F+5 meeting at the
packager?s facility$ a control system PC2 compati%ility test at the packager?s facility
prior to F+5$ and a post:F+5 punch list meeting at the packager?s facility with follow:
up via e:mail. +lso participation in a pre:commissioning meeting$ as well as
assistance in installation$ pre:commissioning$ commissioning$ start:up and site
acceptance tests.8' 2u%mission of all general arrangement drawings$ process instrumentation
drawings$ electrical drawings$ ca%le schedules$ PC2 &and FB' mod%us interface
lists$ cause effect diagrams$ inspection and test plans$ weld procedures$ torsional
analyses$ I2+ instrument data sheets and other documents required to fully define
and characteriDe the equipment %eing supplied and to ena%le Mustang Canada Inc.
and Husky Energy to design the facility as well as install$ inspect and maintain the
equipment.
,7' +fter drawings that have received final design approval for fa%rication$ the supplier
shall then provide an as:shipped set of drawings to characteriDe the actual
configuration of each package as it left the factory$ an as:installed set of drawings tocharacteriDe the actual configuration of each package as it was installed and pre:
commissioned in the topsides fa%rication yard$ and an as:%uilt set of drawings to
depict the actual configuration of each package after offshore commissioning.
,,' 0ual language &English ) French' instructions for all equipment associated with fire
suppression systems and for any su%mitted M202 documents.
)*I-+++- irewater Pumps Pac/age Page of 0
8/18/2019 EOI-101414-404 - Firewater Pumps Package
5/6
,>' 5he supply of all electric motors$ generators$ instrumentation$ electrical components$
electrical systems and wiring with a C2+ la%el and in accordance with all C2+
requirements.
,9' Compliance with Canadian and C*4(P< !egulatory requirements.
,=' 5he supply of all special tools$ capital spares$ and start:up and commissioning spares asdefined in the purchase order. Commissioning spares shall include spare cards and P4Cs for
any control systems. 5he supplier shall advise the Client when spares must %e ordered so they
can %e manufactured with the main equipment.
,A' eighing of all equipment e"ceeding A777 kg with load cells having and accuracy of 6):, of
the measured value. 5he plan center of gravity shall also %e verified using this equipment. 2kids
systems shall not %e disassem%led to avoid the weighing of equipment in this fashion. +
weight data sheet shall %e supplied for all equipment provided. 5he supplier shall quantify the
weight of all skids and ma#or components as early as possi%le in the proposal and design
phases and shall offer weight reduction alternatives for consideration %y the Client.
,;' 5he application of all necessary resources to meet agreed equipment delivery dates$ especiallyafter schedule slippages$ parts scrapping and other unanticipated schedule impacts.
,/' E"port %o"ing and long:term preservation for all equipment.
'4) (perator training
Su."ission an* Re%istration Require"ents1
Mustang Canada Inc. is committed to providing a safe$ healthy and environmentally sound
workplace for its employees$ contractor and su%contractors. Interested companies must meet$
at a minimum$ all requirements of Mustang Canada Inc.$ as well as Husky Energy?s
commitments related to Canada:*ewfoundland and 4a%rador %enefits and other appropriate
regulatory processes. In addition$ interested Companies are required to complete the Mustang
Canada Inc. 2upplier Pre:Jualification Juestionnaire that must %e su%mitted with their
E"pression of Interest. 5he questionnaire is availa%le %y contacting-
,. hite !ose E"tension Pro#ect e%site5el- 6,&/78' /89:9,,9E:Mail- Procurement!EP1mustangeng.come%site- http-))sites.mustangeng.com)sites)
>.
8/18/2019 EOI-101414-404 - Firewater Pumps Package
6/6
Sche*ule1
It is anticipated that the !equest for Proposal &!FP' will %e issued within =:; weeks$ with aplanned award date ,st Juarter >7,=. 5he !equired on 2ite &!(2' delivery for Firewater PumpsPackage is 9rd Juarter >7,A.
)*I-+++- irewater Pumps Pac/age Page 0 of 0