CUPOLAdecon1
oll Free: 1800 671 864 E-mail: [email protected] Visit: www.enware.com.au
nware Australia Pty Limited: 9-11 Endeavour Road, Caringbah, NSW 2229 Australia
Tel: +61 2 9525 9511 Fax:+61 2 9525 9536
nware Asia Safety System Pte Ltd: Block 1003 TOA PAYOH Ind Park #02-1519 Singapore, 319075
Tel:+65 6536 2687 Fax:+65 6536 2689
7/27/2019 ENW206 - Cupola 1 Shelter - FEB 07
2/4
WHITEFIELD ROAD,
BREDBURY, STOCKPORT
CHESHIRE, SK6 2SS
UNITED KINGDOM
Tel: +44 (0(161 430 6618
Fax: +44 (0)161 430 7928EMAIL: [email protected]
CUOL
CUP
OLA
eon
d
econ
1
TECHNICAL SPECIFICATION
WARRANTY INFORMATION
he model offered would be guaranteed against bad workmanship or faulty materials for a period of 12
months from despatch our works.
MATERIALS DIMENSIONS (ERECTED)
nflatable Frame: Neoprene coated polyester Length: 4050 mm
iner: Polyurethane coated polyester Width: 3450 mm
ump: Nylon/butyl/nylon Height: 2940 mm
ection Partitions: Polyurethane coated polyester
Cordage: Terylene or nylon
DIMENSIONS (PACKED)
VALVES Length: 1400 mm
nflate only: Rectus type 25 KS NW 7.8 Width: 680 mm
nflate/Deflate: Type A5 Height: 400 mm
Relief: Mirada 0.2 bar Weight: 75 kgs
MISCWater Flow Rate: 75 Litres/minute
Water Inlet Size & Type: 2 off 19mm( inch) Geka quick
coupling
Assembly Time: Less than 8 minutes
7/27/2019 ENW206 - Cupola 1 Shelter - FEB 07
3/4
WHITEFIELD ROAD,
BREDBURY, STOCKPORT
CHESHIRE, SK6 2SS
UNITED KINGDOM
Tel: +44 (0)161 430 6618
Fax: +44 (0)161 430 7928EMAIL: [email protected]
CUOL
CUPO
LA
eon
de
con1
he CUPOLAdecon1 is a multi-personnel Rapid Decontamination Shelter comprising a
eavy-duty inflatable frame and removable, disposable inner lining, which incorporates an
tegral sump fitted with drain outlets in each corner. The inner lining has three separate
alk-through sections, two of which can accommodate two-stage decontamination the third
eing used for either non ambulant casualties (stretcher cases) or for Emergency Servicesonitoring personnel. To ensure thorough decontamination, each outer section is fitted with
ur or five sets of showering nozzles, these nozzles are situated above and on either side of
e casualty. When a four shower system is adopted in each outer section these can be fed
om two separate water feed pipes and therefore will allow individual dosing using detergent
nd additives. When entering the shower section the first two shower systems could deliver
luted detergent whilst the second two shower system would be for final rinse, and therefore
ould have induced additive. The Twin Inducer is ideally suited for this process. When the
UPOLAdecon1 is not in use it is stored in a valise-type storage bag along with a hand pump,
pair kit, guy lines, mallet and pegs.
he two outer sections of the CUPOLAdecon1 are for separating males from females during the
ass decontamination process, whilst the third section would normally be used for the Emergency
ervice personnel who are monitoring the decontamination process. This centre section also allows
e Emergency Services personnel to assist casualties that may need specialist attention. Shouldecontamination of non-ambulant casualties be necessary then one partition could be removed to
oduce a wider section to facilitate the fitting of a roller bed, with the advantage of access to both
des. When a partition is removed for the purpose of manual decontamination by the Emergency
ervices of non ambulant casualties or casualties needing assistance then a hand-held shower
corporating multi-facility spray heads, suspended on 1.5 metre long flexible hoses can be connected
y self sealing auto shut off valves to one of the external main water feed pipes. These two external
ater feed pipes consists of 19mm() lay-flat hose fed from 19mm() Geka quick couplings.
he CUPOLAdecon1 is exceptionally stable even in strong blustery winds. The arch shape of the
eavy-duty inflatable frame is designed to deflect wind and increase stability and therefore minimize
e effect on the structure. In addition, the shelter can be anchored using the fitted guy lines pegged to
e ground or to fixed structures. The frame is made from a tough, neoprene coated polyester material,
nd is fitted with pressure relief valves to prevent over-pressurisation. The inner lining is removabler easy and safe disposal, and is made from bright yellow fluorescent coated polyester to ensure
aximum internal light during the day and night (all lighting external).
he CUPOLAdecon1 can be accessed from both sides but is intended for the movement of casualties
one direction only. The entrance and exit sides are clearly marked for instant recognition and
asualties are guided through each stage of the process with pictograms indicating the action to be
ken and the direction of movement. Interchangeable pictogram signs are fitted above each entrance
hich allows the operators to section off the decontamination units dependent on gender or for clearly
arking which cubicles are being used for stretchered casualties.
etergent can be added to the shower warm water supply for more effective decontamination using
xternal Chemical Inducers fitted in the supply line. The double chamber inducers have provision
r the introduction of one or two water additives depending on the type contamination. They can be
dividually adjusted to deliver a concentration between 0.2% and 10% depending on the type of unit
sed and the selected inducer setting. The two inducer chambers can operate in parallel or series to
fer a choice of configurations to suit the particular circumstances. Alternatively, water feeding the
ower in the second cubicle could have a different additive, such as saline solution.
ur or five people at a time.
7/27/2019 ENW206 - Cupola 1 Shelter - FEB 07
4/4
Some or all of the internal partitions can be removed to reduce the number, but increase the size
f cubicle, offering an exceptionally flexible arrangement to suit a wide range of likely scenarios.
Stretchers can be supported and manoeuvred on an optional free-standing fold-out Roller Bed that
tretches the full length of the designated section. When not in use the hinged Roller Bed sections fold
p for compact storage and easy handling.
An integral nylon/butyl/nylon sump is incorporated within the lining. All used water is contained within
he sump and can be pumped out for safe testing and disposal from the 19mm() outlets fitted to each
f the four corners. Plastic Floor Panels are laid in the sump to ensure users are not standing in theontaminated wash-off. For transportation and storage the Floor Panels can be stacked; in addition,
Floor Matting can be laid over the panels for comfort and safety. Four weatherproof air vents are also
tted in the roof section for improved ventilation.
De-Robe and Re-Robe Shelters are available for connecting to either end of the
CUPOLAdecon 1. As most standard decontamination procedures involve the removal of clothing
ollowed by the fitting of temporary garments prior to approaching the showering area, it is therefore
mportant that an area is assigned for the privacy of both male and female casualties. With the
CUPOLAdecon 1 this is achieved with the de-robing area which is large enough for the undressing of
our or five people at a time.
For Re-robing in privacy a shelter can be provided which is large enough for casualties to dry
hemselves and re-dress using the post decontamination clothing that will be provided. The De-Robe
nd Re-Robe shelters are available in two sizes either 3 metres long or 4 metres long; normally itwould be advisable to have the 3 metre for de-robing and the 4 metre section for re-robing
. Choice of shower head configuration - ensuring thorough decontamination.
UNIQUE DESIGN DETAILS
. The unit can be operational within 8 minutes.
. Arched shaped heavy duty frame - to withstand extreme weather conditions including
blustery storms.
. 2-Stage showering system with additive inducing - for total flexibility of use.
. Shower system capable of being connected to Chemical Inducers and Water Heater -
for improved decontamination action.
. External water feed pipe - outside contaminated area, avoiding contamination.
. Fluorescent yellow inner lining - to ensure maximum internal light during day and night.
. Removable and replaceable inner lining - for safe disposal or decontamination, andinexpensive replacement.
. Integral sump with four waste outlets - for easier removal of contaminated wash-off.
0. Sumps made from materials used by the military for NBC protection.
1. Sumps designed to accept standard Floor Panels - for comfort and safety.
2. Weatherproof air vents - to improve air circulation.
3. Removable curtains - for a choice of cubicle configurations from 1 to 15.
4. Zip doors - to eliminate overspray and allow easy access.
ANCILLARY EQUIPMENT APPLICABLE FOR USE WITH THIS PRODUCTDe robe shelter
Re robe shelter
12 off Floor Panels
Floor Matting
Waste Water Pump
6000 Litre Portable Reservoir
Waste Receptacles
Waste Outlet Hose
Twin Inducer
Water Inlet Manifold
Air Regulator & Hoses
Air Inflator (Electric)Portaheater 100
Misc Hoses
Warm Air Heater (for De robe & Re robe
areas
Light Units
Generator Sets
Misc Electrical Connection Wires &
Extension Cables
Thermal Cover (or Camouflage Cover)
43 Litre Stacking Decon Trays
Portable Ultrasonic Atomizer
Portable Air Movement Fan
Roller Bed
CUPOLAdecon1
nware Australia Pty Limited: 9-11 Endeavour Road, Caringbah, NSW 2229 AustraliaTel : +61 2 9525 9511 Fax:+61 2 9525 9536
WHITEFIELD ROAD,
oll Free: 1800 671 864 E-mail: [email protected] Visit: www.enware.com.au
nware Asia Safety System Pte Ltd: Block 1003 TOA PAYOH Ind Park #02-1519 Singapore, 319075Tel: +65 6536 2687 Fax: +65 6536 2689W206 Cupola 1 Shelter FEB 07