Environmentally Sealed Pedestal Series brought to you by channell

Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

USA: Channell Commercial Corporation, Temecula, CA • Tel. 800.423.1863 • Fax. 951.296.2322CANADA: Channell Canada, Inc., Mississaugua, Ontario • Tel. 905.565.1700 • Fax. 905.565.8282

EUROPE, MIDDLE EAST, AFRICA: Channell Ltd., London, UK • Tel. 44.1689.871522 • Fax. 44.1689.833428AUSTRALIA, ASIA, PACIFIC RIM: Channell Pty. Ltd., Seven Hills, Australia • Tel. 61.2.8884.4111 • Fax. 61.2 8814.8841

WORLDWIDE HEADQUARTERS: Channell Commercial Corporation • Tel. 951.719.2600 • 26040 Ynez Road • P.O. Box 9022 • Temecula, CA 92589-9022 USA

www.channell.comAll specifications subject to change without notice. Printed in U.S.A. 05132500M.

© 2013 Channell Commercial Corporation. All rights reserved. Dedicated to protecting fiber optics through design, innovation, and service.

Environmentally Sealed Pedestal

Series

brought to you by channell

60441_Brochure.r2-CS6.indd 3 6/4/13 4:45 PM

Page 2: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Hostile Environments Flash is Here...BEWARE!

Flash is a tough, environmentally sealed pedestal series. Flash uses its superhuman strength to protect fiber from any environmental element that comes its way. No matter the air, water, dirt, snow, flood, drought or ultraviolet light it encounters, Flash remains sealed, and the ultimate protector. Flash has encountered the test standards and defeated them all, even the occasional bicycle or skateboard villain!

Introducing Flash: The Superhero of Environmentally Sealed Pedestals.

60441_Brochure.r2-CS6.indd 4 6/4/13 4:45 PM

Page 3: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Flash 9" x 20" (228mm x 508mm) atop Bulk Vault, 17" x 30" x 24" (432mm X 762mm X 610mm)

Dedicated to protecting fiber optics through design, innovation, and service.

cable management

Pit / Vault

System Series

brought to you by channell

Bulk Brochure

What is the Bulk?The Bulk is an upgradeable, re-enterable cable management vault system series with the highest performance standards in the industry; making it the leader of the underground.

Flash is a tough, environmentally sealed pedestal series that serves as the ultimate protector in extremely hostile weather environments. • Environmentally sealed: air/water tight• Weatherproof and flood proof• Meets test standards of GR 771-CORE,- IP68, and IEC 61300• Structural integrity: impact/solvent/UV resistant

Flood

Snow

Wind

Force

Fl a s h : T h e U lt i m at e Pr ot ec t o r A g a i n s t :

Hostile Environments Flash is Here...

The Dynamic Duo

Flash and the Bulk join forces to bring you strength, accessibility, and an optimal above and below ground fiber optic splice and cable management system. Together, this dynamic duo is invincible against any hostile environment it encounters.

60441_Brochure.r2-CS6.indd 5 6/4/13 4:46 PM

Page 4: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

The Destiny of Flash is in Your Hands

2) Above ground pedestal or below grade enclosure? Flash can interchangeably perform in either application.

Above ground pedestal application: • Plugs directly into Bulk’s split thermoplastic lid

• Is easily accessible in hostile weather environments and in areas that require regular access

Below grade closure application:• Attaches directly to Bulk’s swing arm bracket• Is less susceptible to damage and out of sight in areas of high traffic• Can house a variery of closures and dome lengths, depending upon vault size:

Size # of Closures Dome Length

1730 (BULK 3) one 15" (381mm) one 20" (508mm) 2436 (BULK 4) one 15" (381mm) one 20" (508mm) one 24" (610mm) 2448 (BULK 5) two 15" (381mm) one 20" (508mm) one 24" (610mm) 3048 (BULK 7) two 15" (381mm) one 20" (508mm) one 24" (610mm) 2476 (BULK 6) two 15" (381mm) two 20" (508mm) two 24" (610mm)

With the support of Bulk, Flash has the ability to perform as an above ground pedestal with Bulk’s split thermoplastic pedestal plug lid, or a below grade enclosure with Bulk’s swing arm attachment.

1) Select your Bulk vault

The Bulk’s universal vault body and split thermoplastic pedestal plug lid is available in a wide range of sizes:• 1730(BULK3)• 2436(BULK4)• 2448(BULK5)*• 3048(BULK7)• 2476(BULK6)*

*Available in 2014

Bulk vault with split thermoplastic pedestal plug lid

Flash in above ground application, atop Bulk vault with split thermoplastic lid

Flash in below grade application, attached to Bulk’s swing arm bracket (blown fiber without dome shown)

60441_Brochure.r2-CS6.indd 6 6/4/13 4:46 PM

Page 5: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

The Destiny of Flash is in Your Hands

2) Above ground pedestal or below grade enclosure? Flash can interchangeably perform in either application.

Above ground pedestal application: • Plugs directly into Bulk’s split thermoplastic lid

• Is easily accessible in hostile weather environments and in areas that require regular access

Below grade closure application:• Attaches directly to Bulk’s swing arm bracket• Is less susceptible to damage and out of sight in areas of high traffic• Can house a variery of closures and dome lengths, depending upon vault size:

Size # of Closures Dome Length

1730 (BULK 3) one 15" (381mm) one 20" (508mm) 2436 (BULK 4) one 15" (381mm) one 20" (508mm) one 24" (610mm) 2448 (BULK 5) two 15" (381mm) one 20" (508mm) one 24" (610mm) 3048 (BULK 7) two 15" (381mm) one 20" (508mm) one 24" (610mm) 2476 (BULK 6) two 15" (381mm) two 20" (508mm) two 24" (610mm)

Together, Flash and the Bulk deliver a patented Channell design: The Plug N Play®.

The Plug N Play® feature provides ultimate access by giving technicians the option of splicing Flash on land, in their service vehicle, or in the vault.

How? Technicians simply disconnect Flash from Bulk, splice where they choose, and then reinstall Flash to Bulk.

U lt i m at e ver s at i l i t y !

Above ground pedestal

Step #1

Step #2

Step #3

Subsurface enclosure

Specification

ANSI/ SCTE 77

AS/NZ 3996:2006

EN 124:1994

Performance Category

Light Duty Pedestrian Only

Light Duty Pedestrian Only

Light Duty Pedestrian Only

Region

Americas

Australia, New Zealand, Asia

UK, Europe, Africa, Middle East

Application(Installation Location)

Non-vehicular traffic limited to light vehicle. Includes grass surround; if in designated walkway, coefficient of friction should be > 0.5

Non-vehicular traffic limited to pedestrians and cyclists. Areas closed to other traffic

Non-vehicular traffic limited to pedestrians and cyclists. Areas closed to other traffic

GVW

5,000lbs.

670kg

1000kg

Max Wheel Load

2,000lbs.

335kg

500kg

Design Load

2,000lbs.

6.7kN

10kN

Test Load

3,000lbs

10kN

15kN

Load Category

Light Duty, Pedestrian

Class A

Class A 15

Bulk Speci f icat ions

60441_Brochure.r2-CS6.indd 7 6/4/13 4:46 PM

Page 6: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Optimal Fiber Splice Management System

The Seal of Steel Channell’s lubricated grommet sealing technology offers an instant, reliable, and guaranteed environmental seal with superior cable retention:

• Offers both cable retention and a guaranteed seal in a single unit

• Completely environmentally sealed: air/water tight, weatherproof, and flood proof (in accordance with GR-771-CORE, and IEC 61300 requirements)

• Quick, efficient, and tool-less installation: on average, takes less than 1 minute to install

• Superior pull out strength

• Accommodates multiple cable configurations

• Long-term structural integrity

High Drop Density• Yields the lowest installation cost

• Increases system reliability by reducing the number of fiber access points

• Accommodates up to 72 drops per closure

Installation at the Speed of LightTool-less installations that are quick and simple make FiberX products the fastest to install in the industry.

Flash is a powerfully versatile product series due to its wide range of capabilities and customizable configuration options. Flash offers solutions to both blown fiber and conventional fiber placement methodologies.

FiberX “ Special Weapons”

60441_Brochure.r2-CS6.indd 8 6/4/13 4:46 PM

Green HornetTM FlashTM Bulk TM Optimus TM Yellow Jacket TM

Page 7: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

FiberX “ Special Weapons”

Dedicated to protecting f iber optics through design, innovation, and service.

En v i r o n m e n ta l P er fo rm a n c e

Item

1

2

3

4

5

6

7

8

9

Test

Thermal Aging

Assemby and Reconfiguration

Temperature/Humidity Cycling

Temperature Cycling

Freeze/Thaw

Water Resistance

Corrosion Resistance

Chemical Resistance

UV Resistance

Reference Specification

GR-771 5.4.1

IEC 61300-2-33, GR-771 5.4.2

GR-771 5.4.3

IEC-61300-2-22

GR-771 5.4.4

IEC-61300-2-23, GR-771 5.4.6

IEC-61300-2-26, GR-771 5.5.3

IEC 61300-2-34, GR-771 5.5.4

GR 771- 5.5.5

Requirements

Sealing

Appearance, Tightness

Appearance, Tightness

Appearance, Tightness, Sealing

Appearance, Tightness

Sealing

Appearance, Sealing

80% Property retention

80% Property retention

M ec h a n i ca l P er fo rm a n c e S equ e n c e

Item

1

2

3

4

5

6

7

8

9

10

11

Test

Cable Clamping

Sheath Retention

Cable Flexure

Cable Torsion

Vertical Drop

Crush Resistance

Axial Compression

Impact - Drop Tube

Water Resistance

Central Strength Member

Vibration

Reference Specification

GR-771 5.3.1

IEC 61300-2-4, GR-771 5.3.2

IEC 61300-2-37, GR-771 5.3.3

IEC 61300-2-5 ; GR-771 5.3.4

GR-771 5.3.5

IEC 61300-2-10, GR-771 5.3.6

IEC-61300-2-11

IEC 61300-2-12, GR-771 5.3.7

IEC 61300-2-23 ; GR-771 5.4.6

IEC 61300-2-11, GR-771 5.3.10

GR-771 5.3.9 ; IEC-60068-2-6

Requirements

Appearance, Tightness,Optical Measurements

Appearance, Tightness, Optical Measurements

Appearance, Tightness, Optical Measurements

Appearance, Tightness, Optical Measurements

Appearance, Tightness

Appearance, Tightness

Appearance, Tightness

Appearance, Tightness

Appearance, Tightness, Sealing

No protrusion

Appearance, Tightness

T e s t P er fo rm a n c e M ea sur e s

Criteria

Sealing

Tightness

Appearance/Visual

Optical Measurements

Reference Specification

IEC 61300-2-23; GR-771 5.4.6

IEC 61300-2-38

IEC61300-3-1

IEC 61300-3-3, 5, and 44 ; GR-771 A.2

Requirements

No water intrusion

No continuous air escape

No performance effecting damage

Attenuation change

GR-771-CORE = The Americas IEC 61300 = International: Australia, New Zealand, Asia, Europe, Africa, Middle East

Flash Speci f icat ions

Requirements

water intrusion

FLASH!

60441_Brochure.r2-CS6.indd 9 6/4/13 4:46 PM

Page 8: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Conventional Fiber

o p t i m a l f i b e r s p l i c e m a n a g em e n t s y s t em

Splice Tray Design

• Hinged, stackable, and removable, which enables technicians to splice inside the closure, or remove trays and splice outside of the closure

• Accommodates single-fusion, mass-fusion, or mechanical splicing

• Each splice tray accommodates up to 24 single-stacked splices or 48 double-stacked splices

• Compatible with passive optical filters such as: multiplexers, splitters, and patch panels

Slack Storage Tray

• Allows any expressed or uncut tubes/fibers to be looped, stored, and routed within the back of the enclosure

• Permits more slack and better organization

Splice Holders

• Accommodate, secure, and protect single-stacked or double-stacked splices

• Each splice tray features 2 splice holders

• Each holder has a max capacity of 12 single-stacked spliced or 24 double- stacked splices

• Accommodates passive optical components such as splitters and CWDM multiplexers

Drop Door Access

• Lockable drop door access

Flash 9"x 24" (229mm x 610mm) shown with square trays, spliced with conventional fiber. NOTE: Oval trays also available.

60441_Brochure.r2-CS6.indd 10 6/4/13 4:47 PM

Green HornetTM FlashTM Bulk TM Optimus TM Yellow Jacket TM

Page 9: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Flash 6"x 20" (152mm x 508mm) with single circuit and single element oval trays, atop Bulk vault 17" x 30" x 24" (432mm X 762mm X 610mm) Note: single trayselement shown in blue

Conventional Fiber

Dedicated to protecting f iber optics through design, innovation, and service.

FLASH 9

Size: 9" x 20" (229MM x 508MM) 9 " x 24 " (229MM x 610MM)

• Max Splice Capacity: 6 splice trays: 144 single-stacked 288 double-stacked

• Drop Density: 16 drop ports, 1 main oval port, 2 branch ports, 1 ground port

Flash 9” x 24” (229mm x 609mm) with 24 fiber splicing circuit flat trays, atop Bulk vault 24" x 36" x 24" (610mm X 914mm X 610mm)

FLASH 6

Size: 6” x 15” (152MM x 381MM) 6" x 20" (152MM x 508MM)

• Max Splice Capacity: 4 splice trays: 96 single-stacked 192 double-stacked

• Drop Density: 16 drop ports, 1 main oval port, 1 branch port, 1 spare port for bonding and grounding

FLASH 6FLASH 6FLASH

POW!

60441_Brochure.r2-CS6.indd 11 6/4/13 4:47 PM

Page 10: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

Blown Fiber

Green HornetTM • FlashTM • BulkTM • OptimusTM • Yellow JacketTM

Flash 9" x 24" (229mm x 609mm) shown with oval trays and spliced with blown fiber

Tray Design

• The oval tray design used in blown fiber applications allows you to mix and match the tray modules to create a customized combination of single circuit and single element trays. Therefore, the max splice capacity may vary depending on what combination is used.

• Can accommodate passive optical components such as splitters (photo not shown)

Size: 9” x 20” (229MM x 508MM)• Max Splice Capacity: – 56 Single Circuit Trays – 4 splices per tray – 224 fiber splices – 28 Single Element Trays – 12 splices per tray (double-stacked) – 336 fiber splices (double-stacked)• Max Drop Density: 72 individual drops

Size: 9” x 24” (229MM x 609MM)• Max Splice Capacity: – 88 Single Circuit Trays – 4 splices per tray – 352 fiber splices – 44 Single Element Trays – 12 splices per tray (double-stacked) – 528 fiber splices (double-stacked)• Max Drop Density: 72 individual drops

Single circuit tray Single element tray

o p t i m a l f i b e r s p l i c e m a n a g em e n t s y s t em

60441_Brochure.r2-CS6.indd 12 6/4/13 4:47 PM

Page 11: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

The Xconnect is a special weapon used by the FiberX team to connect the central network to the blown fiber tubes; and most importantly, protect this connection.

• Capable of connecting and protecting 10 blown fiber tubes

• Environmentally sealed: Air tight/water tight

• Impervious to hostile environments

• Quick installation

Blown Fiber

Dedicated to protecting f iber optics through design, innovation, and service.

Connect & Protect with the FiberXconnect

CONNECT

Environmentally sealed with Channell’s lubricated grommet sealing technology.

Blown fiber Flash unit includes tubes and endcaps

Xconnect with blown fiber tubes

60441_Brochure.r2-CS6.indd 13 6/4/13 4:47 PM

Page 12: Environmentally Sealed Pedestal Seriesitepeyac.com/wp-content/uploads/2018/03/FlashBrochure.pdfIEC 61300-2-38 IEC61300-3-1 IEC 61300-3-3, 5, and 44 ; GR-771 A.2 Requirements No water

USA: Channell Commercial Corporation, Temecula, CA • Tel. 800.423.1863 • Fax. 951.296.2322CANADA: Channell Canada, Inc., Mississaugua, Ontario • Tel. 905.565.1700 • Fax. 905.565.8282

EUROPE, MIDDLE EAST, AFRICA: Channell Ltd., London, UK • Tel. 44.1689.871522 • Fax. 44.1689.833428AUSTRALIA, ASIA, PACIFIC RIM: Channell Pty. Ltd., Seven Hills, Australia • Tel. 61.2.8884.4111 • Fax. 61.2 8814.8841

WORLDWIDE HEADQUARTERS: Channell Commercial Corporation • Tel. 951.719.2600 • 26040 Ynez Road • P.O. Box 9022 • Temecula, CA 92589-9022 USA

www.channell.comAll specifications subject to change without notice. Printed in U.S.A. 05132500M.

© 2015 Channell Commercial Corporation. All rights reserved.

FiberXTM is a superhero fiber optic product team in the Channell Universe that is dedicated to the protection of fiber optics. FiberX is committed to making the world of fiber optics a better place through design, innovation, and service.

FiberX products feature an optimal fiber splice management system that is simple, organized, and craft-friendly. With a wide range of features and accessories, FiberX

offers a customized solution to meet the needs of any FTTX application.

The strength of FiberX has evolved from Channell’s 90 years of experience and leadership in thermoplastic enclosures for the telecommunication and broadband

industries. FiberX embodies the same patented, reliable, and proven features that have contributed to Channell’s reputation and great success.

For more information about fiberX products, Call 800-423-1863.