You can’t manage what you don’t measure.
If you can’t measure it, you cant improve it.
-Peter Drucker -
Lifecycle solutions for Energy Efficiency
Energy Audit& Measure
Passive Energy Efficiency
Fix the basics
Low consumption devices, insulation material, power factor correction
Lifecycle solutions for Energy Efficiency
Energy Audit& Measure
Passive Energy Efficiency
Optimise through automation & regulation
Fix the basics
Low consumption devices, insulation material, power factor correction
HVAC control, lighting control, variable speed drives…
Lifecycle solutions for Energy Efficiency
Energy Audit& Measure
Active Energy EfficiencyPassive Energy Efficiency
Optimise through automation & regulation
Monitor, maintain, improve
Fix the basics
Low consumption devices, insulation material, power factor correction
HVAC control, lighting control, variable speed drives…
Meters installation, monitoring services, EE
analysis software
… thanks to a combination of
30% savings are available today…En
ergy
Co
nsum
ption
100%
70%
Effici
ent d
evic
es a
nd
inst
alla
tion
(10
to 1
5%)
Monitoring & Maintenance(2 to 8 %)
• Up to 8% per year is lost without monitoring and maintenance program• Up to 12% per year is lost without regulation and control systems
Time
Opti
miz
ed u
sage
via
au
tom
ation
(5 to
15%
)
… but savings can be lost quickly…En
ergy
Co
nsum
ption
100%
70%
Effici
ent d
evic
es a
nd in
stal
latio
n
Opti
miz
ed u
sage
via
aut
omati
on
Monitoring & Maintenance
Time
● Unplanned, unmanaged shutdowns of equipment and processes
● Lack of automation and regulation (motors, heating)
● No continuity of behaviours
Up to 8% per year is lost without monitoring and maintenance program
Up to 12% per year is lost without regulation and control systems
How to get the data?
Measuring
• Manual oriented (by human)
• Non-real-time• Uncontionus
Monitoring
• Automatic oriented (by an integrated system)
• Real-time• Continuous
Measuring EquipmentFor Water, Air, Gas, Electricity, Steam
Electricity
PM, SEPAM, MCB, MCCB, ACB, Capacitor, VSD, etc
Non-Electricity
Flow Meter – liquid/gas
(Data Concentrator is needed)
Power Quality Issues
• Harmonic Distortion
Distorted = Base + Harmonic
Non-linear load:o Switched mode power
supplies (SMPS)o Electronic fluorescent
lighting ballastso Variable speed drives
(VSD)o Uniterruptible power
supplies (UPS)o Magnetic-cored
devices
Solution: Harmonic Filter/Conditioner
Injects in opposite phase of the harmonics drawn by the non-linear load. (Iact=-Ihar)
So its remains sinusoidal
• Power Factor
In Indonesiacos Ø > 0.85
(PLN Standard)o Increase kVA needs
o Decrease power distribution efficiency
o Increase heat on equipments
o Low electricity quality because voltage drop
Ratio of the real power flowing in the circuit
Solution: Controlling Power Factor on Grid
Capacitor:
Reduce reactive powerVarlogic (PF Controller):
Controlling capacitor steps
Soft Starter and Variable Speed Drives allows:Smooth start and stop to avoid belt slip
ELEKTRONIKo SOFT STARTERo INVERTER (VSD)
• Digital computer used for automation• For industrial electromechanical processes• Based on basic digital gate logic + pascal logic
(NOT, AND, NAND, OR, NOR, XOR, XNOR, IF, THEN) expressed in ladder languange
Progammable Logic Controller
• Digital computer used for automation• For industrial electromechanical processes• Based on basic digital gate logic + pascal logic
(NOT, AND, NAND, OR, NOR, XOR, XNOR, IF, THEN)