19
1 Energy Conversion Devices Technology Roadmap Update June 1, 2010 © 2010 Energy Conversion Devices

Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

1

Energy Conversion Devices

Technology Roadmap Update

June 1, 2010

© 2010 Energy Conversion Devices

Page 2: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

2

Safe Harbor

THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS

PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE

SECURITIES EXCHANGE ACT OF 1934

These forward-looking statements do not constitute guarantees of future performance. Forward-looking

statements include statements concerning our plans, objectives, goals, strategies, future events, future

net sales or performance, capital expenditures, financing needs, plans or intentions relating to

expansions, business trends and other information that is not historical information. All forward-looking

statements are based upon information available to us on the date of this presentation and are subject to

risks, uncertainties and other factors, many of which are outside of our control, that could cause actual

results to differ materially from the results discussed in the forward-looking statements. Risks that could

cause such results to differ include: our ability to maintain our customer relationships; the worldwide

demand for electricity and the market for solar energy; the supply and price of components and raw

materials for our products; and our customers’ ability to access the capital needed to finance the

purchase of our products. The risk factors identified in the ECD filings with the Securities and Exchange

Commission, including the company’s most recent Annual Report on Form 10-K and Quarterly Reports

on Form 10-Q, could impact any forward-looking statements contained in this presentation.

© 2010 Energy Conversion Devices

Page 3: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

3

ECD is Moving Forward

• Growing pipeline

• Improving revenue and cash flow

• Increasing production

• Reducing inventory

© 2010 Energy Conversion Devices

Page 4: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

4

Project Pipeline of 200+ MW

25 MW ENEL installation sites in Nola, Italy. Equivalent to powering 13,000 households.

World’s largest integrated roof-top project

Photo rendering.

© 2010 Energy Conversion Devices

Page 5: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

5

0.7

1.7

0.7

1.6

Expanding Commercial

New BAPV PowerTilt

Current BIPV Products

Commercial Market Size (GW)

Source: 2010 Solarbuzz Market Report – Green World Scenario; EUPD; ECD Analysis

BIPV

BAPV

Low Load

20132010

1.4 GW

3.3 GW Products

© 2010 Energy Conversion Devices

Page 6: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

6

Residential Product Roadmap

© 2010 Energy Conversion Devices

EnerGen

Shingle

Tile

North America

Summer 2010

2011

Future

Europe

Page 7: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

7

Photo

Court

esy

of

RH

EIN

ZIN

K

0.3

0.9

2.0

3.2

2010 2013

Europe

North

America

Residential Market Size (GW)

2.3 GW

4.1 GW

Source: 2010 Solarbuzz Market Report – Green World Scenario; EUPD; ECD Analysis

Entering Residential

5.6 kW residential installation in Germany

© 2010 Energy Conversion Devices

Page 8: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

8

The UNI-SOLAR Difference Today

Energy Yield* (kwh/ kW)

Weight (lbs/sq. ft.)

Conversion Efficiency (%)

System Price ($/Watt)

LCOE ($/ kwh)

1300 – 1500

2.4 – 4.0

9 – 22

$3.50 – $4.80

$0.18 – $0.25

1600+

0.7

8.2

$4.00

$0.19

Competition Today

© 2010 Energy Conversion Devices

UNI-SOLAR Today

Assumes Southern California example, large project (500KW), 7.5% IRR with 50% levered, 0% ITC,

1.0% commercial retail electricity power price escalator (DOE). Includes installation, O&M costs.

Page 9: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

9

Our Technology

© 2010 Energy Conversion Devices

Blue

Absorbing Cell

Integrating

Green Absorbing

Cell

Integrating

Red Absorbing

Cell

Technology Today

Solar Spectrum

Page 10: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

10

Small area machine 2” by 2” substrate Large area machine 15” by 14” substrate

Large-area machine (three 14” webs) Roll-to-roll production machine

From Lab to Production

© 2010 Energy Conversion Devices

Page 11: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

11

Roadmap to 20+%

• Light Trapping

• High Rate Deposition

• HybridNano Technology

Conversion Efficiency

© 2010 Energy Conversion Devices

Current CY 2011 CY 2012 Potential

8.2%

10%

12%

Lab

15.4%

20+%

Page 12: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

12

Improved Light Trapping: Back Reflector

© 2010 Energy Conversion Devices

Improved Light Trapping

Anti-reflective coating

Blue light-absorbing cell

Green light-absorbing cell

Red light-absorbing cell

Back reflector

Stainless steel substrate

Cross-section of a solar cell

Page 13: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

13

Proprietary cathode design: demonstrated on 42” wide production machine span

Current• 8.2% efficiency in production

Demonstrated• ~10% efficiency

at 2x the deposition rate

• Reduced cost-per-watt

and capex-per-watt

High Rate DepositionDouble throughput from same machines at higher conversion efficiencies

Demonstrated Uniform Deposition Over Large Area

© 2010 Energy Conversion Devices

Page 14: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

14

HybridNano TechnologyResults in greater stability and higher conversion efficiency

© 2010 Energy Conversion Devices

HybridNano Technology

replaces green and red

light-absorbing layers

• Compatible with a-Si alloy deposition

• Ideal for middle and bottom cells of multi-junction structure

• Improved light absorption and no light-induced degradation

of nano layers has resulted in conversion efficiency of 11%,

target of ~12%

Anti-reflective coating

Blue light-absorbing cell

Green light-absorbing cell

Red light-absorbing cell

Back reflector

Stainless steel substrate

Cross-section of a solar cell

Page 15: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

15

Today

Advanced photon

harvesting and

innovative deposition

process

© 2010 Energy Conversion Devices

Advanced Photon Harvesting Improving cell quality to achieve 25% cell efficiency goal

Solar Spectrum

Page 16: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

16

$1.50

$0.95

$2.00

$0.20

$0.35

$0.45

$1.55

Today's Technology Manufacturing Conversion Efficiency (12%) Balance of System Target

$3.50

$2.50

Reducing ’s Total Installed Price

Roadmap to SustainabilityTotal installed price

© 2010 Energy Conversion Devices

Figures based on full utilization

Laminate

cost

Balance of

systems

and other

Page 17: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

17

The UNI-SOLAR Difference Differentiated product with superior energy yield, competitive system price

and conversion efficiency

Energy Yield (kWh/ kW)

Weight (lbs/ft2)

Conversion Efficiency (%)

System Price ($/Watt)

LCOE unsubsidized ($/kWh)

© 2010 Energy Conversion Devices

1600+

0.7

12

$2.50

$0.12

UNI-SOLAR Target

Assumes Southern California example, large project (500KW), 7.5% IRR with 50% levered, 0% ITC,

1.0% commercial retail electricity power price escalator (DOE). Includes installation, O&M costs.

Page 18: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

18

Targeting Grid Parity – USA

© 2010 Energy Conversion Devices

Electricity Cost

(per kWh)

Installed System Price

($/Watt)

Commercial Retail Electricity RateGrid Parity

Transitional Sustainable

Assumes Southern California example, large project (500KW), 7.5% IRR with 50% levered, 0% ITC,

1.0% commercial retail electricity power price escalator (DOE). Includes installation, O&M costs.

Page 19: Energy Conversion Devices - Uni-Solar · 2017-03-07 · 2 Safe Harbor THIS PRESENTATION CONTAINS FORWARD-LOOKING STATEMENTS PURSUANT TO THE SAFE HARBOR PROVISIONS OF THE SECURITIES

19

Questions?

© 2010 Energy Conversion Devices