37
ENCLOSURE 4 to AW-17-4519 APP-GW-GLY-129, Revision 0 "Updates to WCAP-17938 Resulting from Sanmen Hot Functional Testing Observations - Closed Meeting" (Non-Proprietary)

Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

ENCLOSURE 4 to AW-17-4519

APP-GW-GLY-129, Revision 0 "Updates to WCAP-17938 Resulting from Sanmen Hot Functional Testing Observations -

Closed Meeting"

(Non-Proprietary)

Page 2: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

This presentation is non-proprietary

AP1000® is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the Unit~d States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

e Westinghouse APP-GW-GLY-129 Revision 0

1

Page 3: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

e) Westinghouse

APP-GW-GLY-129 Revision 0 2

Page 4: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Objective:

• Inform NRC Staff about Neutron Shielding observations from Sanmen & proposed revisions to WCAP-17938

• Receive and discuss NRC Staff feedback

Agenda:

• Issue Overview

• Design Assessment

• Revisions to Topical Report

• Schedule

8 Westinghouse APP-GW-GLY-129 Revision 0

3

Page 5: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

e) Westinghouse APP-GW-GLY-129 Revision 0

4

Page 6: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Design Overview Reactor Vessel Neutron Shielding Locations

(9 Westinghouse APP-GW-GLY-129 Revision 0

CA31

5

Upper Neutron Shield (UNS)

Lower Neutron Shield (LNS)

a,c

Page 7: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

• Neutron shield blocks are integrally designed into the CA31 module that forms the floor of the refueling cavity.

e Westinghouse APP-GW-GLY-129 Revision 0

6

a,c

a,c

Page 8: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

• Volumetric expansion of shielding material was not properly considered within the design and construction

• Material off gassing was greater than expected causing internal pressurization of the shield blocks

Level I CAPAL was generated and RCA was conducted

e) Westinghouse APP-GW-GLY-129 Revision 0

7

a,c

a,c

Page 9: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse APP-GW-GLY-129 Revision 0

a,c

Page 10: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Neutron Shielding Issue Resolution Problem Statement - M N20 • Purpose of MN20 blocks is to reduce radiation

streaming from the reactor cavity annulus and into the lower reactor cavity.

• Inspection of LNS did not indicate any block displac~ment or deformation due to thermal expansion

8 Westinghouse APP-GW-GLY-129 Revision 0

9

a,c

a,c

Page 11: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse APP-GW-GLY-129 Revision 0

10

a,c

a,c

Page 12: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

8 Westinghouse APP-GW-GLY-129 Revision 0

11

Page 13: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

New shield block configuration • Reconfigured existing neutron blocks mounted on CA31

(9 Westinghouse APP-GW-GLY-129 Revision 0

12

a,c

Page 14: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Reconfigure existing neutron block

8 Westinghouse APP-GW-GLY-129 Revision 0

13

a,c

Page 15: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

New supplemental shielding block

e Westinghouse APP-GW-GLY-129 Revision 0

ac

a,c

14

Page 16: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

8 Westinghouse APP-GW-GLY-129 Revision 0

15

a,c

Page 17: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

8) Westinghouse APP-GW-GLY-129 Revision 0

16

Page 18: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

e Westinghouse APP-GW-GLY-129 Revision 0

17

a,c

Page 19: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

a,c

APP-GW-GLY-129 Revision 0 18

Page 20: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

APP-GW-GLY-129 Revision 0

LNS design is less susceptible to the effects of thermal expansion

a,c

Page 21: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse APP-GW-GLY-129 Revision 0

20

Page 22: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Impacts to Technical" Report (TR) WCAP-17938 Revision 1

• The overall premise, objectives, and conclusions of the TR

do not change.

• The TR will continue to provide an integrated assessm~nt of

AP1000 in-containment cables and the suitability of non­

metallic insulation (NMI) in the reactor cavity

e Westinghouse APP-GW-GLY-129 Revision 0

21

a,c

Page 23: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electri.c Company LLC. All Rights Reserved.

Impacts to Technical Report (TR) WCAP-17938 Revision 1

• Regulatory impacts remain unchanged

(9 Westinghouse APP-GW-GLY-129 Revision 0

22

abc

Page 24: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

8 Westinghouse APP-GW-GLY-129 Revision 0

23

Page 25: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(8 Westinghouse APP-GW-GLY-129 Revision 0

24

a,c

Page 26: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

ENCLOSURE 5 to AW-17-4519

APP-GW-GLY-127, Revision 0 "Updates to WCAP-17938 Resulting from Sanmen Hot Functional Testing Observations - Public

Meeting"

(Non-Proprietary)

Page 27: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

This presentation is non-proprietary

AP1000® is a trademark or registered trademark of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited. Other names may be trademarks of their respective owners.

(9 Westinghouse APP-GW-GLY-127 Revision 0

1

Page 28: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse

APP-GW-GLY-127 Revision 0 2

Page 29: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Objective:

• Inform NRC Staff about Neutron Shielding observations from Sanmen & proposed revisions to WCAP-17938

• Receive and discuss NRC Staff feedback

Agenda:

• Issue Overview

• Design Assessment

• Revisions to Topical Report

e Westinghouse APP-GW-GLY-127 Revision 0

3

Page 30: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse APP-GW-GLY-127 Revision 0

4

Page 31: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Design Overview Reactor Vessel Neutron Shielding Locations

(9 Westinghouse APP-GW-GLY-127 Revision 0

CA31

5

Upper Neutron Shield (UNS)

Lower Neutron Shield (LNS)

Page 32: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

• CA31 Neutron shield blocks are integrally designed into the CA31 module that forms the floor of the refueling cavity

• During Hot Functional Testing high temperature plateaus, shielding material contained in CA31. volumetrically expanded and extruded out of the shield blocks into the nozzle gallery

• Volumetric expansion of shielding material was not properly considered within the design and construction

• Purpose of MN20 blocks is to reduce radiation streaming from the reactor cavity annulus and into the lower reactor cavity.

• MN20 is susceptible to the same failure mode (thermal exp.ansion) as CA31 - UNS and LNS contain the same shielding materjal

• Inspection of LNS did not indicate any block displacement or deformation due to thermal expansion

(9 Westinghouse APP-GW-GLY-127 Revision 0

6

Page 33: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

8 Westinghouse APP-GW-GLY-127 Revision 0

7

Page 34: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

• CA31 shielding material has b~en replaced with a different material, that will not experience similar expansion issues

• Extent of Condition was performed on MN20 locations, considering laboratory testing, site inspections and analysis

• The conservative decision was made to also replace the neutron shielding material in the MN20 UNS - These components will no longer require non-metallic

insulation

• The evaluations also determined that it was not necessary to replace the neutron shielding material in the MN20 LNS

(9 Westinghouse APP-GW-GLY-127 Revision 0

8

Page 35: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

(9 Westinghouse APP-GW-GLY-127 Revision 0

9

Page 36: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Impacts to Technical Report (TR) APP-GW-GSR-012 Revision· t

• The overall premise, objectives, and conclusions of the TR

do not change. • The TR will continue to provide an integrated assessment of

AP1000 in-containment cables and the suitability of non­metallic insulation (NMI) in the reactor cavity

• Pertinent sections of the TR will be revised or enhanced to

reflect the changes in shielding material • UNS is removed from the scope of the WCAP since it is no

longer a potential debris source

(9 Westinghouse APP-GW-GLY-127 Revision 0

10

Page 37: Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, … · 2017. 3. 9. · Enclosure 4 to AW-17-4519, APP-GW-GLY-129, Revision 0, "Updates to WCAP-17938 Resulting from Sanmen Hot

Westinghouse Non-Proprietary Class 3 © 2017 Westinghouse Electric Company LLC. All Rights Reserved.

Impacts to Technical Report (TR) APP-GW-GSR-012 Revision 1

• Jet impingement sections of the TR will be revised to confirm NMI suitability with both types of shielding material - The jet impingement testing still defines the ZOI for NMI suitability

equivalency - Locations used in jet impingement testing still remain conservative

• Sections of the TR related to in-containment cables and debris generation break size remain unchanged

• The justification from the Chemical Debris Evaluation is unchanged, due CA31 and LNS shielding blocks encapsulation

• Regulatory impacts remain unchanged

(\9 Westinghouse APP-GW-GLY-127 Revision 0

11