    Relays

    Technical Data

    Relay 736

    Description

    Polarized latching relay for 100 A.

    The relays are designed and manufactured in accord-

    ance to the Standards of IEC 61810, Part 1-00/VDE 0435,

    Part 201, which are also in accordance to the Low

    Voltage Directive (LVD).

    The advantage of the polarized latching relays is the pulse

    driven operation of 30 miliseconds. Therefore there is

    a low need of setting power and the coil heating can be

    neglected.

    The relays are designed and manufactured in accordance

    to international standards of IEC 61810 part 1/VDE 0435

    part 201 as well as they meet overload and short circuit

    requirements of IEC 62053/62054/62055(UC3).

    1/3

    Technical data

    Coil data Rated voltage 6 48 VDC

    Rated power 16 W

    Operating power to set 11 W

    Pulse to set 30 ms

    Action time < 15 ms

    Contact data Max. contact arrangement 3 a

    Contact material AgSnO2

    Max. switching power 25,000 VA

    Max. switching voltage 440 VAC

    Max. switching current 100 A

    Mechanical life 106

    Insulation Creepage and clearance distancecoil contact

    8 mm

    Test voltagecoil contact

    4,000 V eff.

    Test voltagecontact contact

    4,000 V eff.

    Test voltageopen contact

    1,000 V eff.

    Dielectric strengthcoil contact

    12 kV / 1.2 / 50 s

    General data

    Ambient temperature -40 +75 C

    Weight 360 g

    Conform to VDE, UL, CSA, SEV, SEMKO

  • 7/30/2019 en736

    2/3

    Relays >> Technical Data

    2011-12-13Copyright

    byGRUNERAG

    Subjecttotechnicalchangesanddesignmodifications

    Relay 736

    2/3

    The power terminals can be modified according to customer specification.

    A shunt is integrated into one of the power terminals of the type 736 CR. It is used to

    measure the energy consumed and, as it is integrated in the relay, can be utilised for

    load shedding in Energy Management. Two connectors are located on the terminal

    close to the shunt and only carry the current sensor signal. A third connector is the

    reference signal for the electronics and is located on the supply side of the terminal to

    avoid RF sensitivity.

    Identification

    Example for ordering

    Further versions

    on request

    Identification code

    Type 736

    Version B = see d im. drawing

    CR = see dim. drawing

    Contact material R = AgSnO2

    Contact a rrangement 3A = 3 normal ly open

    Terminal-grid B

    Winding No. see coil table

    736 R BB - -3A 9R0

    Standard windings

    Contact position

    Terminal-grid B 2/3 (+) 1/2 (+)

    The relay can also be used with a single

    winding (lower operating power to set) if

    the middle pin of coil is not used.

    Standard winding

    No.

    Nominal coil

    voltage

    Operating voltage

    of the coil

    Coil resistance Tolerance

    Double winding (VDC) U1 U2 (VDC) (Ohm) ( %)

    2R2 6 4.8 7.8 2 x 2.2 10

    9R0 12 9.6 15.6 2 x 9 10

    035 24 19.2 31.2 2 x 35 10

    140 48 38.4 62.4 2 x 140 10

  • 7/30/2019 en736

    3/3

    Relays >> Technical Data

    GRUNER AG

    D-78564 Wehingen Germany

    Phone +49 7426 948-0 Fax +49 7426 948-200 www.gruner.de [email protected]

    2011-12-13Copyright

    byGRUNERAG

    Subjecttotechnicalchangesanddesignmodifications

    Technical drawing

    51,4

    0,3

    0

    10

    23

    8,5

    tbd.

    10 14,5 14,5 14,5 14,5 14,5

    17,7

    6

    34,5

    0,2

    0

    25,2

    10,79,59,5

    3

    LineOut

    LineOut

    LineIn

    LineIn

    LineOut

    LineIn

    128 0,30

    3

    30

    3

    12

    3

    736 CR

    Shunt 736 CR

    at 20 C: 170

    at 0 C: -0.1 %

    at 75 C: -0.2 %

    at 150 C: -0.6 %

    Further resistance values

    upon request

    10 14,5 14,5 14,5 14,5 14,5

    8,5

    1023

    51,4

    0,3

    0

    10

    9,2 17 12 17 12 17

    7

    17,7

    6

    128 0,30

    36,0

    0,2

    0

    3

    10,79,5

    25,2

    9,5

    3

    12

    3

    tbd.

    LineOut

    LineOut

    LineIn

    LineIn

    LineOut

    LineIn

    736 B

    3/3