    dipl.ing. J. Jordi, EMV-Technik Solothurn

    Regulation EN55011:1998+A1:1999+A2:2002

    Industrial. Scientific and medical (ISM) radio frequency equipment.

    Limits and methods of measurement

    The amendment A2 came into force the August 1 st, 2002.

    By July 1st, 2005 the regulation EN 55011:1998 only is legally valid, when therequirements of amendment A2:2002 are complied with.

    The list beneath will show you the most important reforms and change of regulationEN55011:98. These are contained in the amendment A2:02

    The limits (peak / average) of table 2a refer to the spectrum of conductiveinterference voltage, measured on the 3x400Vac mains lines of equipments class Agroup 2. (150kHz < f < 30MHz). These limits and the method of measurement haveno change with regard to the regulation EN55011:98

    The limit of table 5b refer to EDM and arc welding machines. This limit andthe method of measurement have changed and are published in theamendment A2:2002

    EN55011:98+A1:99+A2:02

    ChapterNew aspects of amendment A2:2002 compared with

    regulation EN 55011:1998

    4Organization of ISM-

    equipements

    The manufacturer of ISM-equipments has to advise theuser about the specific characteristics of equipment class A

    group 2, by installing of a label or by a reference to the

    operating manual.

    see 4.1 and 4.2

    4.1 Separation in groupsISM-equipment of the group 2 produce intentional HF-

    energy for metal handling purposes.

    4.2 Subdivision into classes

    Equipments of class A must respect the limit A. Theseequipments may neither be installed nor applied in

    domestic areas.

    The operating manual refers to the potential emission ofRFI by equipments class A group 2.

    5.1.2.1

    Continuous RFI emissionin the range of

    frequencies

    150kHz

  • 8/6/2019 EN55011Requierment

    2/3

    dipl.ing. J. Jordi, EMV-Technik Solothurn

    Table 2a Limits of RFI emission (ISM-equipment class A group 2)

    Measurement on the 3x400Vac mains lines by use of the LISN 50 or probe 1500

    Table 5b Limit of EM-radiation, emitted by EDM (ISM-equipment class A) New version

    Distance between DUT and antenna: D = 10m