What are Best Practices?What are Best Practices? Best Practices is using Innovative Technologies
along with New Field Practices to increase plantefficiency
Field Practices
Innovative
Technology
+EngineeringProcurementInstallation
Commissioning
CAPEX
7/29/2019 Emerson Pressure Best_practices
2/29
@ r Q p r H h h t r r
S r 9 v v v 8 s v q r v h y
T y v q r " ! ( P p
2SHUDWLRQDO,P
SURYHPHQ
W
4XDOLW\
3URGXFWLY
LW\
8SWLPH
7/29/2019 Emerson Pressure Best_practices
3/29
The 3051S Series of Instrumentation
The Platform That Enables Best Practices
The 3051S Series of Instrumentation
The Platform That Enables Best Practices
Scalable Platform
Integrated Solutions
Advanced Functionality
Diagnostics
2X the Performance
2X the Reliability
7/29/2019 Emerson Pressure Best_practices
4/29
The 3051S Series of Instrumentation
Scalability for a Single Plant Wide Platform
The 3051S Series of Instrumentation
Scalability for a Single Plant Wide Platform
ScalablePerformance
0.04% Accuracy
10 Year Stability
12 Year Warranty
0.065% Accuracy
5 Year Stability
Scalable Process Connections
Scalable
PlantWebFunctionality &Diagnostics
Scalable Electrical Connections
7/29/2019 Emerson Pressure Best_practices
5/29
Pressure Best Practices to improve your
Plant Efficiency
Pressure Best Practices to improve your
Plant Efficiency Select Reliable & High Installed Performance Devices to
improve plant efficiency (Quality, Throughput & Availability)
Use Transmitter Platforms with functionality that enables directmountingminimizing capital and maintenance costs
Leverage Diagnostics to improve plant availability throughpredictive maintenance
Use a Scalable Platform that meets all your plant needs today
and allows the flexibility for adding enhancements
7/29/2019 Emerson Pressure Best_practices
6/29
Reducing Process Variability Increases
Plant Efficiency
Reducing Process Variability Increases
Plant Efficiency
7/29/2019 Emerson Pressure Best_practices
7/29
20
30
30
20
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Optimum InstrumentTuning Design
Source of Variability
In Process Control Loops
30%
30%
Source: Entech---Results fromaudits of over 300 process plants
Process Variability depends on the quality of
process measurement by the field instruments
Process Variability depends on the quality of
process measurement by the field instruments
Total Performance
How accurate is the measurement?
ReliabilityHow long will it work?
Dynamic Response Time
How closely does it track theprocess?
7/29/2019 Emerson Pressure Best_practices
8/29
Select Transmitters based on TotalPerformance
3051S Provides Highest Performance
Select Transmitters based on TotalPerformance
3051S Provides Highest Performance
Reduce measurement errors up to 50%
Error % Flow Reading
+/- 25 F 200 psi 18 Months
2x Improvement
Example: DP Flow Application
3051S
Typical .075%Smart
0.2% Analog
7/29/2019 Emerson Pressure Best_practices
9/29
Select Transmitters based onTotal Performance over 5 to 10 years
3051S Reduces Maintenance Costs
Select Transmitters based onTotal Performance over 5 to 10 years
3051S Reduces Maintenance Costs
Increased Reliability and Stability reduces calibration frequency,
periodic maintenance, repairs and inventory costs.
3051S MaintenanceSavings =$150 - $400perCalibration
perunit
peryear!
7/29/2019 Emerson Pressure Best_practices
10/29
Select Inherently ReliableTransmitters
3051S is Designed for Reliability
Select Inherently ReliableTransmitters
3051S is Designed for Reliability
Hermetic, All-welded,316L SST Housing
Withstands the Harshestof Environments
Optimizes Performance andDiagnostic Capabilities
SaturnTM CapacitanceSensing Technology
Single Circuit BoardDesign
Improves Performanceand Reliability
Multi-bus OutputScalable Functionality,
Output Protocol Flexibility
Coplanar Process IsolatorsProvides reliable interface for
manifolds, seals and primaries
Improves Reliability,
Enables Scalable Design
Patented ASICTechnology
7/29/2019 Emerson Pressure Best_practices
11/29
@ r Q p r H h h t r r
S r 9 v v v 8 s v q r v h y
T y v q r ! ( P p
)DVW'\QDPLF5HVSRQVHLVHVVHQWLDOIRU)DVW'\QDPLF5HVSRQVHLVHVVHQWLDOIRU
0HDVXUHPHQW$FFXUDF\'LDJQRVWLFVDQG6DIHW\0HDVXUHPHQW$FFXUDF\'LDJQRVWLFVDQG6DIHW\
7UDQVPLWWHU 5HVSRQVH7LPH
6 PVHF
PVHF
PVHF
!PVHF
7\SLFDO6+DVWKH)DVWHVW'\QDPLF5HVSRQVH7LPH
7/29/2019 Emerson Pressure Best_practices
12/29
I/O Scan Rate Recommended
Xmtr Response Time (Dead Time + 1 TimeConstant)
500ms 250ms Normal Control Applications
250ms 125ms ESD, Compressor, Turbine, etc
Remote
Set Point
PV
Cascade
ControlMaster
Slave
Slave Update
5X Master
Select Transmitter with
Response Time < of Controller Scan Rate
Select Transmitter with
Response Time < of Controller Scan Rate
7/29/2019 Emerson Pressure Best_practices
13/29
Pressure Best Practices to improve your
Plant Efficiency
Pressure Best Practices to improve your
Plant Efficiency Select Reliable & High Installed Performance Devices to
improve plant efficiency (Quality, Throughput & Availability)
Use Transmitter Platforms with functionality that enables directmountingminimizing capital and maintenance costs
Leverage Diagnostics to improve plant availability throughpredictive maintenance
Use a Scalable Platform that meets all your plant needs today
and allows the flexibility for adding enhancements
7/29/2019 Emerson Pressure Best_practices
14/29
@ r Q p r H h h t r r
S r 9 v v v 8 s v q r v h y
T y v q r # ! ( P p
6HOHFW7UDQVPLWWHUSODWIRUPVWKDW
HQDEOH'LUHFW0RXQWLQJ
6HOHFW7UDQVPLWWHUSODWIRUPVWKDW
HQDEOH'LUHFW0RXQWLQJ6'LUHFW0RXQW,QVWDOODWLRQ
,QWHJUDWHG6ROXWLRQ
7/29/2019 Emerson Pressure Best_practices
15/29
3051S Integrated Solutions to Reduce
Capital & Maintenance Costs
3051S Integrated Solutions to Reduce
Capital & Maintenance Costs
Engineering
Procurement
Installation
Commissioning
Level
Flow
Pressure
7/29/2019 Emerson Pressure Best_practices
16/29
Today
3051S
Reduce Maintenance & Troubleshooting
3051S Scaled Variable Enables
Application Specific PV - Level
3051SScaledVariableEnables
Application Specific PV - Level
7/29/2019 Emerson Pressure Best_practices
17/29
3051S Low Flow Cut-Off Enables
Application Specific PV - Flow
3051S Low Flow Cut-OffEnables
Application Specific PV - FlowReduce Maintenance & Troubleshooting
Operate as a
Flowmeter
7/29/2019 Emerson Pressure Best_practices
18/29
Select Reliable & High Installed Performance Devices toimprove plant efficiency (Quality, Throughput & Availability)
Use Transmitter Platforms with functionality that enables directmountingminimizing capital and maintenance costs
Leverage Diagnostics to improve plant availability throughpredictive maintenance
Use a Scalable Platform that meets all your plant needs today
and allows the flexibility for adding enhancements
Pressure Best Practices to improve your
Plant Efficiency
Pressure Best Practices to improve your
Plant Efficiency
7/29/2019 Emerson Pressure Best_practices
19/29
Select Transmitters with
Diagnostics to Reduce Maintenance
Select Transmitters with
Diagnostics to Reduce Maintenance3051S Temperature Alerts:
Enhance Availability
Prevent freezing of impulse lines
3051S Pressure Alerts:
Field Indication of your Pressure
Alarms
High & Low Indication
3051S
7/29/2019 Emerson Pressure Best_practices
20/29
TransmitterOutput
Time
Signal Inside Transmitter Contains the
Information Needed for Diagnostics!
Select Transmitters with Process
Diagnostics to Increase Plant Availability
Select Transmitters with Process
Diagnostics to Increase Plant Availability
3051S Speed &
ResolutionEnables Process
Diagnostics for
Predictive
Maintenance
7/29/2019 Emerson Pressure Best_practices
21/29
Select Transmitters that provide
Plugged Line Detection
Select Transmitters that provide
Plugged Line DetectionDetection = Safety
Detection of
Onscale Failures
Prediction =Availability3051S Plugged Line
Detection
7/29/2019 Emerson Pressure Best_practices
22/29
Select Transmitters that provide
Statistical Process Monitoring
Select Transmitters that provide
Statistical Process Monitoring
3051S Statistical Process Monitoring
Abnormal ProcessVariability Detection
= Safety &Availability
7/29/2019 Emerson Pressure Best_practices
23/29
Select Reliable & High Installed Performance Devices toimprove plant efficiency (Quality, Throughput & Availability)
Use Transmitter Platforms with functionality that enables directmountingminimizing capital and maintenance costs
Leverage Diagnostics to improve plant availability throughpredictive maintenance
Use a Scalable Platform that meets all your plant needs today
and allows the flexibility for adding enhancements
Pressure Best Practices to improve your
Plant Efficiency
Pressure Best Practices to improve your
Plant Efficiency
7/29/2019 Emerson Pressure Best_practices
24/29
Scalable Platform: A Design that Allows Flexibility
3051S True Scalability
Scalable Platform: A Design that Allows Flexibility
3051S True Scalability
Scalable
Performance
0.04% Accuracy
10 Year Stability
12 Year Warranty
0.065% Accuracy
5 Year Stability
Scalable Process Connections
Scalable
PlantWeb
Functionality &
Diagnostics
Scalable Electrical Connections
7/29/2019 Emerson Pressure Best_practices
25/29
Save
62%
Many Vendors,
Transmitters, Parts
One Vendor, Integrated
Platform, Reduced Parts
Standardize
andOptimize
Standardize on a Scalable Platformto reduce inventory & training costsStandardize on a Scalable Platformtoreduce inventory & training costs
3051S Allows 62% Savings in Inventory & Replacements
Scalable
Performance
ScalableConnections
Scalable
Functionality
7/29/2019 Emerson Pressure Best_practices
26/29
@ r Q p r H h h t r r
S r 9 v v v 8 s v q r v h y
T y v q r ! & ! ( P p
6HOHFWDSODWIRUPGHVLJQHG
IRUILHOGHQKDQFHPHQWV
6HOHFWDSODWIRUPGHVLJQHG
IRUILHOGHQKDQFHPHQWV
7/29/2019 Emerson Pressure Best_practices
27/29
Select Reliable & High Installed Performance Devices toimprove plant efficiency (Quality, Throughput & Availability)
Use Transmitter Platforms with functionality that enables directmountingminimizing capital and maintenance costs
Leverage Diagnostics to improve plant availability throughpredictive maintenance
Use a Scalable Platform that meets all your plant needs today
and allows the flexibility for adding enhancements
Pressure Best Practices to improve your
Plant Efficiency
Pressure Best Practices to improve your
Plant Efficiency
7/29/2019 Emerson Pressure Best_practices
28/29
Scalable
Performance
0.04% Accuracy
10 Year Stability
12 Year Warranty
0.065% Accuracy
5 Year Stability
Scalable Process Connections
ScalablePlantWeb
Functionality &Diagnostics
Scalable Electrical Connections
3051S Series of Instrumentation
A Scalable Platform that Enables Best Practices
3051S Series of Instrumentation
A Scalable Platform that Enables Best Practices
7/29/2019 Emerson Pressure Best_practices
29/29
3051S Series of Instrumentation
The Platform to Improve Your Bottom Line
3051S Series of InstrumentationThe Platform to Improve Your Bottom Line
Level
Flow
Pressure