Emergency stop rope pull switches Preventa XY2CCatalogue
Emergency stop rope pull switches Preventa XY2C
Emergency stop rope pull switches Preventa XY2C
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages.2.to.4 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.5 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.6 XY2CHorderform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.7 XY2CEorderform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.8 Separatecomponentsreferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page.9 Mountingaccessoriesandkitsreferences. . . . . . . . . . . . . . . . . . . . . . . . .page.9 Replacementpartsreferences. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page.10. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.11
Rope pull switches Preventa XY2CB
Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.12 Ropepullswitchesreferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page.13 Separatecomponentsandreplacementpartsreferences. . . . . . . . . . . .page.14 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.15
Product reference index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page.16
Contents
1
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
2
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
Presentation Emergency stop rope pull switchesEmergencystopropepullswitchesaredesignedto:baverthazards(dangerousphenomena)attheearliestpossiblemoment,ortoreduceriskswhichcouldcauseinjurytopersonsordamageeithertomachinesorworkinprogress,bbetrippedbyasinglehumanactionwhenanormalEmergencystopfunctionisnotavailable,b tripintheeventoftheropepullbreaking.
Emergencystopropepullswitchesareessentialinpremisesandonmachinesthatarepotentiallydangerouswheninoperation.Theoperatormustbeabletotriggerthestopinstructionatanypointwithintheirworkingarea.Application examples: woodworkingmachines,shears,conveyorsystems,transfermachines,printingmachines,textilemachines,rollingmills,testlaboratories,paintshops,surfacetreatmentworks.
Installation Typical installation
1 2 3 4 5
8 7 6 1
1 Fixingsupport2 Firstcablesupport3 Turnbuckle
4 Pulleysupportsandpulleys5 Endspring6 Cablegrips
7 Switchadjustment8 Emergencystop
Notes regarding installationbAllXY2CHandXY2CEemergencystopropepullswitchescanbefittedwithapilotlighttoindicatetheirtrippedcondition.bCabletensionadjustmentcanbeperformedusing:vaturnbuckle(tobeorderedseparately,seepage9),v atensioner(integratedincertainXY2CHmodels,seepage9).bThisadjustmentissimplifiedby:vacabletensionindicatorthatisavailableonallmodelsXY2CH,v theavailabilityofversionswitha“cabletensionindicator”windowbystatingitsreferenceontheorderform(seepage8).Example:referenceXY2CE1A250becomesXY2CE1D250.bTheuseofanendspringisstronglyadvisedforconveyorsystemapplicationstoensureoperationoftheEmergencystopintheeventofthecablebeingpulledtowardstheswitch.b Itisessentialthatpulleysbeusedwithropespullthatdeviatefromastraightrun,i.e.angledtoformaprotectedzone.b Important:emergencystopropepullswitchesXY2CHandXY2CEcanbeusediftheinstallationrequiresthattheropepullbeangled.Inthiscase,thetotalsumoftheanglesthroughwhichtheropepullbendsmustnotexceed180°.(Forfurtherinformationoninstructionstobeadheredto,pleaserefertotheinstallationmanual).
General
Characteristics:page5
References:page6
Dimensions:page11
1
2
3
4
5
6
7
8
9
10
3
Safety detection solutionsEmergencystopropepullswitches,PreventaXY2C
General.(continued)
Main features1 2 3
Positive operation:runningcondition
1 Theswitchesincorporatepositiveopeningoperationcontacts,thetrippingoftheswitchbeingmadewithpositiveaction.
Latching:stopinstructiongiven(tripped)
2 Theswitchlatchesinthetrippedposition(NCsafetycontact(s)open).ThefunctionoftheNOcontactispurelyforsignalling.
Resetting:stopcondition(awaitingreset/restart)
3 Theswitchesincorporatearesetbutton,whichre-closesthesafetycontact(s).Restartingofthemachinemustonlybeachievedbymanualoperationofacontroldevicewithinthemachinestartcircuit,remotetotheemergencystopropepullswitches.
Rope pull expansion and contraction: d
Temperaturevariationslikelytobeencounteredintheprotectedzonewillobviouslycausetheropepulltoexpandorcontract.Toenableinstantverificationthattheropepullisatitscorrecttension(andformakinganynecessaryadjustments),emergencystopropepullswitchesXY2CHandXY2CEincorporatearopepulltensionindicator.
Standards EmergencystopropepullswitchesPreventaXY2CHandXY2CEmeetalltherequirementsoftheharmonisedEuropeanstandardEN/ISO 13850,relatingtoEmergencystopdevices.AlltheemergencystopropepullswitchesareemarkedandsuppliedwithanECdeclarationofconformity.
Cable’s diameter Inordertoachievethemaximumcablelength,accordingtoambienttemperaturevariation,werecommendtouse:bgalvanisedcableswithredsheathdiametre3.2mmforXY2CHrangeandbgalvanisedcableswithredsheathdiameter5mmforXY2CErange(seepage9).
d (mm)
1
2
3
4
5
6
7
8
9
10
4
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
General.(continued)
Characteristics:page5
References:page6
Dimensions:page11
Adjustment values (with end spring)
ForemergencystopropepullswitchesXY2CE,theadjustmentvaluesdependonthepositionsofthecamlocatedinsidetheswitch.Theadjustmentismadebyrotatingthecamaftertheswitchhasbeeninstalled.EachnotchedofthecamisreferencedbythelettersAtoFandtheselectedletterisvisiblethroughaviewingport.
Theuseofanendspringisstronglyadvised,soyoucanseethereferencesinthetablebelowregardingeachtype:
Type Position of cam Maximum length of cable End springXY2CH – 30meters XY2CZ703XY2CE A,B,C,D,E,F 70meters XY2CZ702
XY2CH
L (m)
100908070605040302010
50 10 15 20 25 30 m
∆T (°C)
Withthegraphabove,ifweconsideranambienttemperaturevariationof25°C,forexamplefrom0°Cto+25°C,thetablegivesusamaximumcablelengthof30meters.
XY2CE
∆T (°C)
L (m)
A B C D E F
102030405060708090
100
5 10 15 20 25 30 35 40 45 50 55 60 65 70 m0
Withthegraphabove,ifweconsideranambienttemperaturevariationof35°C,forexamplefrom-10°Cto+25°C,thetablegivesusamaximumcablelengthof:b40meterswithcamAadjustments,b70meterswithcamFadjustments.
1
2
3
4
5
6
7
8
9
10
5
Characteristics
EnvironmentConformity to standards Products XY2CH,XY2CE:EN/IEC60947-5-5,EN/ISO13850:2006,UL508
andCSAC22-2n°14(withsuffixH7)Machineassemblies XY2CH,XY2CE:EN/IEC60204-1,Machinerydirective:2006/42/EC,
Workequipmentdirective:2009/104/ECProduct certifications XY2CH, XY2CE:UL-CSA(withsuffixH7),CCC(1)Maximum safety level(2) PLe,category4conformingtoEN/ISO13849-1andSILCL3conformingtoEN/IEC62061Reliability data B10d XY2CH:4,000,000
XY2CE:50,000(datavaluesforaservicelifeof20years:canbelimitedbycontactandmechanicalwear)
Protective treatment Standardversion “TC”Specialversion “TH”
Ambient air temperature Foroperation -25…+70°CForstorage -40…+70°C
Vibration resistance XY2CH:10gn(10…150Hz)XY2CE:10gn(10…300Hz)conformingtoEN/IEC60068-2-6
Shock resistance XY2CH,XY2CE:50gn(duration11ms)conformingtoEN/IEC60068-2-27Electric shock protection ClassIconformingtoIEC61140Degree of protection XY2CH,XY2CE:IP65conformingtoIEC60529(IP66forXY2CEpA1pp,XY2CEpA2pp
andXY2CEpA3pp)Mechanical life XY2CH:800,000operatingcycles
XY2CE:10,000operatingcyclesLength of protected zone (rope pull) XY2CH:y30metres,XY2CE:y70metresDistance between cable supports 5mCable entries XY2CH:tappedentrieswithPg13.5,ISOM20or1/2”NPT.
XY2CE:plainholesforPg13.5,ISOM20or1/2”NPT.Seedimensions,page11.
Contact block characteristicsRated operational characteristics
2-polecontacts XY2CH,XY2CE:AC-15:A300orUe=240V,le=3ADC-13:Q300orUe=250V,le=0.27A,conformingtoEN/IEC60947-5-1AppendixA
3-polecontacts XY2CH,XY2CE:AC-15:C300orUe=240V,le=0.75ADC-13:R300orUe=250V,le=0.1A,conformingtoEN/IEC60947-5-1AppendixA
Nominal thermal current 10ARated insulation voltage 2-polecontacts XY2CH,XY2CE:Ui=500Vdegreeofpollution3conformingtoEN/IEC60947-1,
Ui=300VconformingtoUL508,CSAC22-2n°143-polecontacts XY2CH,XY2CE:Ui=400Vdegreeofpollution3conformingtoEN/IEC60947-1,
Ui=300VconformingtoUL508,CSAC22-2n°14Rated impulse withstand voltage
2-polecontacts XY2CH,XY2CE:Uimp=6kVconformingtoEN/IEC60947-13-polecontacts XY2CH,XY2CE:Uimp=4kVconformingtoEN/IEC60947-1
Positive operation NCcontactwithpositiveopeningoperationconformingtoEN/IEC60947-5-1Section3Contact operation XY2CH,XY2CE (Emergencystop)Resistance across terminals y25mΩconformingtoNFC93-050methodAorEN/IEC60255-7category3Terminal referencing ConformingtoCENELECEN50013Short-circuit protection 2-polecontacts XY2CH,XY2CE:10AcartridgefusetypegG(gl)conformingtoIEC60269
3-polecontacts XY2CH,XY2CE:6AcartridgefusetypegG(gl)conformingtoIEC60269
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
Rated operational power(Electricaldurability)
XY2CH,XY2CEConformingtoEN/IEC60947-5-1AppendixC.UtilisationcategoriesAC-15andDC-13Operatingrate:3600operatingcycles/hour.Loadfactor:0.5
AC supply a50/60HzoInductivecircuit
2-pole contacts 3-pole contacts
0,5 1 2 3 4 5 100,1
0,2
0,5
1
5
2
43
Ithe
230 V 12/24/48 V
110 V
Millionsofoperatingcycles
CurrentinA
Millionsofoperatingcycles
CurrentinA0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
43
Ithe
230 V 110 V12/24/48 V
DC supplycPowerbrokeninWfor1millionoperatingcyclesoinductivecircuit
Voltage V 24 48 120 Voltage V 24 48 120o W 13 9 7 o W 4 3 2
Contact connection ScrewclampterminalsClampingcapacity:min.1x0.5mm2,max.2x1.5mm2
Minimumtighteningtorque:0.8N.m.Maximumtighteningtorque:1.2N.m
(1).Only.products.XY2CH.without.pilot.light.are.CCC.and.UL-CSA.approved .(2).Using.an.appropriate.and.correctly.connected.control.system .
1
2
3
4
5
6
7
8
9
10
6
References
Latching Emergency stops(Pg13.5,integratedturnbuckle,cableandendspringtobeorderedseparately)(1)Without pilot lightLength of cable
Colour of enclosure
Reset Supply voltage
Type of contact Cable anchor point
Reference Weight
kg
y 30 m RedRAL3000bodyandstainlesssteelcover
Bybootedpushbutton
– 1 1 NC+NOslowbreak
Bothsides(rightorleft)
XY2CH13250 (3) 0.865
Bymushroomheadpushbutton
– 1 1 XY2CH13350 (3) 0.900
Bykeyoperatedpushbutton(keyn°421).(2)
– 1 1 XY2CH13450 (3) 0.910
Byflushpushbutton
– 2 – NC+NCslowbreak
Bothsides(rightorleft)
XY2CH13170 (3) 0.865
Bybootedpushbutton
– 2 – XY2CH13270 (3) 0.865
Bymushroomheadpushbutton
– 2 – XY2CH13370 (3) 0.865
Bykeyoperatedpushbutton(keyn°421).(2)
– 2 – XY2CH13470 (3). 0.910
Byflushpushbutton
– 2 1 2NC+1NOslowbreak
Bothsides(rightorleft)
XY2CH13190 (3) 0.865
Bybootedpushbutton
– 2 1 XY2CH13290 (3) 0.865
Bymushroomheadpushbutton
– 2 1 XY2CH13390 (3) 0.865
With pilot light (direct supply)y 30 m RedRAL3000
bodyandstainlesssteelcover
Bybootedpushbutton
24V 1 1 NC+NOslowbreak
Bothsides(rightorleft)
XY2CH13253 0.900
2 – NC+NCslowbreak
XY2CH13273 0.900
2 1 2NC+1NOslowbreak
XY2CH13293 (3) 0.950
Latching Emergency stops(turnbuckle,cableandendspringtobeorderedseparately)(1)Without pilot lighty 70 m(4)
RedRAL3000bodyandstainlesssteelcover
Bybootedpushbutton
– 1 1 NC+NOslowbreak
Rightside XY2CE1A250 (5). 1.450Leftside XY2CE2A250 (5) 1.450
2 – NC+NCslowbreak
Rightside XY2CE1A270 (5) 1.450Leftside XY2CE2A270 (5) 1.450
Bykeyswitch(keyn°421)
– 1 1 NC+NOslowbreak
Rightside XY2CE1A450 (5) 1.465Leftside XY2CE2A450 (5) 1.465
2 – NC+NCslowbreak
Rightside XY2CE1A470 (5) 1.470Leftside XY2CE2A470 (5) 1.470
With pilot light (direct supply) y 70 m(4)
RedRAL3000bodyandstainlesssteelcover
Bybootedpushbutton
24to130V 2 2 NC+NOslowbreak
Rightside XY2CE1A296 1.470Leftside XY2CE2A296 1.470
230to240V 2 2 NC+NOslowbreak
Rightside XY2CE1A297 1.470Leftside XY2CE2A297 1.470
Other versions Seeorderformsonpages7and8.XY2CEwithresetbyØ40mmmushroomheadpushbuttonorwithintegralcabletensionerandsupport.PleaseconsultourCustomerCareCentre.
(1).See.separate.components,.page.9 .(2).Ø.30.spring.return.key.operated.mushroom.head.pushbutton .(3).For.ISO.M20.threaded.cable.entry.version,.add.H29.to.the.end.of.the.reference.selected ...
Example:.XY2CH13250.becomes.XY2CH13250H29 .(4).Available.with.window.for.viewing.cable.tension.indicator,.for.adjustment.whilst.the.cover.is.closed.(see.versions.XY2CEpDppp.
and.XY2CEpEppp on.the.order.form,.page.8) .(5).ATEX.version.available.(products.for.explosive.atmospheres):.To.order,.add.EX.to.the.end.of.the.reference ..
Example:.XY2CE1A250.becomes.XY2CE1A250EX .
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
XY2CE2A250
110940
XY2CH13250
110937
1
2
3
4
5
6
7
8
9
10
7
Order.form..(specimen.suitable.for.photocopying)
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
XY2CH13250
110937
Complete units, pre-assembled
Customer Schneider Electric Industries SACompany OrderN° Deliverydate Salesoffice-SubsidiaryCo. OrderN°
How to use this form:-.indicate.the.number.of.Emergency.stop.switches.required,-.complete.the.basic.reference .
Reference
NumberofidenticalEmergencystops
XY2CH
ModelEmergencystop(latching) 1
Degree of protectionIP65(standardbellows)withintegraltensioner 3IP65(siliconebellows)withintegraltensioner 4
Type of resetEmergencystop(1)Resetbyspringreturnpushbutton
Flush 1Booted 2Mushroomhead,Ø30 3Keyoperatedmushroomhead,Ø30(keyn°421)
4
Keyoperatedmushroomhead,Ø30(keyn°455)
5
Keyoperatedmushroomhead,Ø30(2) 9
Contact blocks for Emergency stop function (3) Slowbreak 1NC+1NO(NOstaggered) 5
2NC 72NC+1NO 9
Pilot lightWithoutpilotlight 0With24Vdirectsupplypilotlight 3With48Vdirectsupplypilotlight 4With130Vdirectsupplypilotlight 5With230Vdirectsupplypilotlight 7
Tapped cable entry1/2"NPT(4) H7ISOM20 H29
Increased protectionTreatmentagainstcorrosion(5) TK
(1).Opening.of.a.circuit.+.mechanical.latching.in.the.open.position .(2).Other.key.numbers:.458A,.520E,.1242A,.1243E,.1344A,.1422A,.1431E,.2123E.and.2132E .(3).Emergency.stop.rope.pull.switches.can.only.be.fitted.with.slow.break.contact.blocks .(4).Only.for.versions.without.pilot.light ..For.versions.with.pilot.light,.order.an.H4.version .(5).Protective.treatment.TK.is.only.possible.for.switches.with.silicone.bellows.(XY2CH14pppTK,.XY2CH14pppH29TK,.etc) .
1
2
3
4
5
6
7
8
9
10
8
Order.form..(specimen.suitable.for.photocopying)
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
Complete units, pre-assembled
Customer Schneider Electric Industries SACompany OrderN° Deliverydate Salesoffice-SubsidiaryCo. OrderN°
How to use this form:-.indicate.the.number.of.Emergency.stop.switches.required,-.complete.the.basic.reference .
Reference
NumberofidenticalEmergencystops
XY2CE
ModelsEmergencystop(latching)
Anchorpointonrightside 1Anchorpointonleftside 2
Degree of protection and “cable tension indicator” windowIP65(standardbellows)without“cabletensionindicator”window AIP65(siliconebellows)without“cabletensionindicator”window CIP65(standardbellows)with“cabletensionindicator”window DIP65(siliconebellows)with“cabletensionindicator”window E
Type of resetEmergencystop(1)Resetbyspringreturnpushbutton
Flush 1Booted 2Mushroomhead,Ø30 3Keyoperatedmushroomhead,Ø30(keyn°421)
4
Keyoperatedmushroomhead,Ø30(keyn°455)
5
Keyoperatedmushroomhead,Ø30(keyn°458Aorn°520E)
9
Contact blocks for Emergency stop function (2) Slowbreak 1NC+1NO 5
2NC 72NC+2NO(compulsorywithpilotlight)(3) 9
Pilot lightWithoutpilotlight 0ProtectedLED,24-130Vsupplyvoltagepilotlight(providefor2contactblocks) 6ProtectedLED,230Vsupplyvoltagepilotlight(providefor2contactblocks) 7
Version for North American countriesTappedcableentry1/2”NPT H7
Increased protectionTreatmentagainstcorrosion(4) TK
(1).Opening.of.a.circuit.+.mechanical.latching.in.the.open.position(2).Emergency.stop.rope.pull.switches.can.only.be.fitted.with.slow.break.contact.blocks .(3).The.use.of.a.pilot.light.means.selecting.a.switch.fitted.with.2.NC.+.2.NO.contacts:.XY2CEppp9p .(4).Protective.treatment.TK.is.only.possible.for.switches.with.silicone.bellows.(XY2CEpCpppTK, XY2CEpEpppH7TK) .
XY2CE2A250
1109401
2
3
4
5
6
7
8
9
10
9
Separate componentsDescription For use with Diameter
mmLengthm
Reference Weight kg
Galvanised cableswith red sheath
XY2CH 3.2 10.5 XY2CZ301 0.280
15.5 XY2CZ3015 0.410
25.5 XY2CZ302 0.690
30.5 XY2CZ303 0.830
XY2CE 5 15.5 XY2CZ1015 0.850
25.5 XY2CZ102 1.400
50.5 XY2CZ105 2.750
70.5 XY2CZ107 3.870
Description Type For use with Sold inlots of
Unit reference Weight kg
Tensioner – XY2CE 1 XY2CZ203 0.090
Turnbuckles M6x60+locknut Allmodels(1) 1 XY2CZ402 0.060
M8x70+locknut Allmodels(1) 1 XY2CZ404 0.100
Cable grips Single CableØ3to5mm 10 XY2CZ503 0.007
Double CableØ3to5mm 10 XY2CZ513 0.016
Clamp CableØ3.2mm 10 XY2CZ523 0.050
CableØ5mm 10 XY2CZ524 0.080
Cable supports Fixed Allmodels 10 XY2CZ601 0.030
Swivelling Allmodels 1 XY2CZ602 0.130
Pulleysupport Allmodels 1 XY2CZ705 0.060
Pulley CableØ5mmmax. XY2CHandXY2CE 1 XY2CZ708 0.002
Cable end protectors – CableØ3.2mm 10 XY2CZ701 0.002
CableØ5mm 10 XY2CZ704 0.010
End springs – XY2CH 1 XY2CZ703 0.035
XY2CE 1 XY2CZ702 0.080
Mounting accessories and kitsContents For use with Cable
diameterLength of cable
Reference Weight
mm m kgBracket XY2CE – – XY2CZ804 0.474
1springtensioner+1notchedwasher+1circlip
XY2CH – – XY2CZ918 0.010
1galvanisedcable+ 1cablegripXY2CZ523+1endspringXY2CZ703
XY2CH 3.2 10 XY2CZ9310 0.415
15 XY2CZ9315 0.535
30 XY2CZ9330 0.915
1galvanisedcable+4cablegripsXY2CZ524+1turnbuckleXY2CZ404,+1cablesupportXY2CZ601+3cableendprotectorsXY2CZ704+1endspringXY2CZ702.
XY2CE 5 25 XY2CZ9525 1.905
50 XY2CZ9550 3.280
70 XY2CZ9570 4.000
(1).Emergency.stop.rope.pull.switches.XY2CH13ppp.and.XY2CH14ppp.incorporate.a.cable.tensioner.as.standard .Therefore,.there.is.no.need.to.order.a.turnbuckle .
References Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
General:pages2to4
Characteristics:page5
Dimensions:page11
803017
XY2CZ402
810060
XY2CZ503
803025
XY2CZ203
803018
XY2CZ602
803020
XY2CZ705
803019
XY2CZ524
810061
XY2CZ601
803016
XY2CZ708
810062
XY2CZ701
810062
803021
XY2CZ702
XY2CZ918
DF601301
+
+
DF601441
XY2CZ804
1
2
3
4
5
6
7
8
9
10
10
References.(continued)
General:pages2to4
Characteristics:page5
Dimensions:page11
Replacement partsDescription For use with Type Reference Weight
kgReset pushbutton (blue), spring return
XY2CH Flushwith“R”markedonpush ZB5AA639 0.018
Booted ZB5AP6 0.019
Mushroomhead,Ø30 ZB5AC64 0.027
XY2CE Flushwith“R”markedonpush ZB5AA639 0.018
Booted ZB5AP6S 0.021
Mushroomhead,Ø30 ZB5AC64 0.027
Key switch XY2CHandXY2CE Withkeyn°421 ZB5AG612R26 0.064
Withkeyn°455 ZB5AG6R26 0.064
Keys for reset button AlltypesofEmergencystop N°421 Q99900911 0.006
N°455 Q99900901 0.006
Pilot light head assembly XY2CE Red XY2CZ800 0.015
Orange XY2CZ801 0.015
Set of 5 cover gaskets XY2CE – XY2CZ805 0.122
Fixing nut, plastic, grey XY2CHandXY2CE – ZB5AZ901 0.002
Fixing nut tightening key,plastic, grey
XY2CHandXY2CEForfixingnutZB5AZ901
ZB5AZ905 0.016
Description For use with Voltage Sold in lots of
Unit reference Weightkg
Pilot lightsWithbulbDL1AApppincluded
XY2CHColour:orange
24V 1 XY2CZ0024 (1). 0.035
130V 1 XY2CZ0130 (1). 0.035
230V 1 XY2CZ0230 (1). 0.035
Supply on LED XY2CEColour:red
24V 1 ZALVB4 0.015
130V 1 ZALVG4 0.015
230to240V 1 ZALVM4 0.015
XY2CEColour:orange
24V 1 ZALVB5 0.015
130V 1 ZALVG5 0.015
230to240V 1 ZALVM5 0.015
Incandescent bulbs, screw base fitting
XY2CH 24V-6W 10 DL1AA024 0.004
130V-6W 10 DL1AA127 0.004
230V-6W 10 DL1AA220 0.004
Set of 5 collars FormountingDL1AA127andDL1AA220bulbsinpilotlightsXY2CZppp
– 5 XY2CZ908 0.018
(1).Only.for.use.as.replacement.parts.for.switches.pre-fitted.with.pilot.lights ..CCC.and.UL-CSA.approvals.no.longer.apply.if.an.XY2CZppp.pilot.light.is.mounted.on.Emergency.stops.XY2CH .
803023
XY2CZpppp
803023
Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
XY2CZ805
601438
1
2
3
4
5
6
7
8
9
10
11
General:pages2to4
Characteristics:page5
Latching Emergency stopsXY2CHWithout pilot light With pilot light
(1).Maximum.extension .(2).Tapped.entries.for.n°.13.(Pg.13 .5).cable.gland ..For.ISO.M20.the.reference.becomes.XY2CHpppppH29 .(3).121.mm:.24.V.and.48.V.versions ..131.mm:.130.V.and.230.V.versions .
XY2CEXY2CE1Appp (anchor point on right side) XY2CEpAppp+ XY2CZ804 bracket
243
Accessories XY2CZ705 XY2CZ708
5355
M 8 Ø 9
(1).3.plain.holes.for.n°.13.(Pg.13 .5).or.ISO.M20.cable.gland .(2).Maximum.extension .Ø:4elongatedholesØ6mm.
68
197
201 (1)
48 56
40 55 (1)
68
(2)(2)
(2)
6,5
68
197
201 (1)
40 55 (1)
(3)
(2)
(2)
48 56
6,5(2)
Dimensions Safety detection solutionsEmergencystopropepullswitchesPreventaXY2C
Ø
120195
12
142
636
44
(1)
57,5
2825
5220
105 (2)
31
(1)
(1)
229 (2)
82
1
2
3
4
5
6
7
8
9
10
12
Characteristics
EnvironmentConformity to standards Products EN/IEC60947-5-1,CSAC22-2n°14(withsuffixH2)Product certifications CSAA600-Q600(withsuffixH2)Protective treatment Standardversion “TC”
Specialversion “TH”Ambient air temperature Foroperation -25…+70°C
Forstorage -40…+70°CElectric shock protection ClassIconformingtoIEC61140Degree of protection Enclosure:IP22,contacthousing:IP65,conformingtoIEC60529Mechanical life 10,000operatingcyclesLength of protected zone y100metresandy2x 100metresDistance between cable supports 5mCable entries Seedimensions,page15.
Contact block characteristicsRated operational characteristics AC-15:A600orUe=600V,le=1.2A
DC-13:Q600orUe=600V,le=0.1A,conformingtoEN/IEC60947-5-1AppendixANominal thermal current 10ARated insulation voltage Ui=500Vdegreeofpollution3conformingtoEN/IEC60947-1,
Ui=600VconformingtoCSAC22-2n°14Rated impulse withstand voltage Uimp=6kVconformingtoEN/IEC60947-1Positive operation NCcontactwithpositiveopeningoperationconformingtoEN/IEC60947-5-1Section3Contact operation “NC+NC”or“NC+NO”slowbreakResistance across terminals y25mΩconformingtoNFC93-050methodAorEN/IEC60255-7category3Terminal referencing ConformingtoCENELECEN50013Short-circuit protection 10AcartridgefusetypegG(gl)conformingtoIEC60269
Rated operational power(Electricaldurability)
ConformingtoEN/IEC60947-5-1AppendixCUtilisationcategoriesAC-15andDC-13
Operatingrate:3600operatingcycles/hourLoadfactor:0,5
AC supplya50…60HzPowerbrokeninVA(1)oInductivecircuitVoltage V 24 48 127 220o VA 250 250 500 500
DC supplycPowerbrokeninW(1)oInductivecircuitVoltage V 24 48 120o W 50 100 100
Contact connection ScrewclampterminalsClampingcapacity:min.1x0.5mm2,max.2x1.5mm2
Minimumtighteningtorque:0.8N.mMaximumtighteningtorque:1.2N.m
(1).For.1.million.operating.cycles .
Detection solutionsRopepullswitchesXY2CB
References:page13
Dimensions:page15
1
2
3
4
5
6
7
8
9
10
13
References Detection solutionsRope pull switches XY2CB
Rope pull switches(End spring, turnbuckle and cable to be ordered separately) (1)Without pilot lightLength of cable
Colour of enclosure
Reset Type of contact Cable anchor point
Reference Weight
kgy 100 m Blue From inside enclosure 1 1 “NC + NO”
slow breakLeft side XY2CB10 (2) 18.750
Right side XY2CB20 (2) 18.750
2 – “NC + NC”slow break
Left side XY2CB104 18.750
Right side XY2CB204 18.750
y 2 x 100 m Blue From inside enclosure 1 1 “NC + NO”slow break
Both sides(right or left)
XY2CB30 (2) 29.250
2 – “NC + NC”slow break
Both sides(right or left)
XY2CB304 29.250
With pilot lightLength of cable
Colour of enclosure
Reset Supply voltage Type of contact Cable anchor point
Reference Weight
kgb Direct supplyy 100 m Blue From inside
enclosure24 V 1 1 “NC + NO”
slow breakLeft side XY2CB11 19.550
Right side XY2CB21 19.550
48 V 1 1 “NC + NO”slow break
Left side XY2CB12 19.550
Right side XY2CB22 19.550
y 2 x 100 m Blue From inside enclosure
24 V 1 1 “NC + NO”slow break
Both sides(right or left)
XY2CB31 25.600
48 V 1 1 “NC + NO”slow break
Both sides(right or left)
XY2CB32 30.050
b Supply via integral transformer (3)y 100 m Blue From inside
enclosure127 V/6 V 1 1 “NC + NO”
slow breakLeft side XY2CB13 15.600
Right side XY2CB23 15.600
220 V/6 V 1 1 “NC + NO”slow break
Left side XY2CB14 15.600
Right side XY2CB24 15.600
y 2 x 100 m Blue From inside enclosure
127 V/6 V 1 1 “NC + NO”slow break
Both sides(right or left)
XY2CB33 25.600
220 V/6 V 1 1 “NC + NO”slow break
Both sides(right or left)
XY2CB34 25.600
(1)Seeseparatecomponents,page4.(2)For1/2”NPTthreadedcableentryversion,addthesuffixH2tothereferenceselected.
Example:XY2CB10becomesXY2CB10H2.(3)BulbDL1CB006included.
XY2CB30
1232
27
XY2CB21
1232
29
XY2CB13
1232
28
1
2
3
4
5
6
7
8
9
10
14
References.(continued)
Characteristics:page12
Dimensions:page15
Separate components and replacement partsDescription Diameter
mmLengthm
Reference Weightkg
Galvanised cableswith red sheath
3.2 10.5 XY2CZ301 0.280
15.5 XY2CZ3015 0.410
25.5 XY2CZ302 0.690
50.5 XY2CZ305 1.360
100.5 XY2CZ310 2.700
Description Type Sold inlots of
Unit reference Weightkg
Turnbuckles M6x60+locknut
1 XY2CZ402 0.060
M8x70+locknut
1 XY2CZ404 0.100
Cable grips forcablesØ3to5mm
Simple 10 XY2CZ503 0.007
Double 10 XY2CZ513 0.016
Cable grips forcablesØ3.2mm
Clamp 10 XY2CZ523 0.050
Cable supports Fixed 10 XY2CZ601 0.030
Swivelling 1 XY2CZ602 0.130
Pulley support – 1 XY2CZ705 0.060
Cable end protectorsforcablesØ3.2mm
– 10 XY2CZ701 0.002
End spring – 1 XY2CZ707 0.314
Description Voltage Sold inlots of
Unit reference Weightkg
Pilot lightsWithbulbDL1AApppincluded
24V 1 9001KP35R9 0.134
120V 1 9001KP1R9 0.210
230V 1 9001KP7R9 0.210
Incandescent bulbs, BA 9s base fitting
24V-2.6W 10 DL1CE024 0.002
6V-1.2W 10 DL1CB006 (1) 0.002
ISO M20 adaptor – 5 DE9RP13520 0.050
(1).For.use.with.XY2CB,.120.V.and.230.V .
Detection solutionsRopepullswitchesXY2CB
803021
XY2CZ707
9001KP35R9
111270
810061
XY2CZ601
803018
XY2CZ602
XY2CZ701
810062
1
2
3
4
5
6
7
8
9
10
15
DimensionsXY2CBWithout pilot light With pilot light
208
4xØ8
210
240
= =
265
112
56
(3)
155 (2)
458
(1) 208
4xØ8
210
240
= =
265
198
56
(3)
155 (2)
523
(1)
80
(1).2.access.points.for.operating.cable .(2).+.125.for.opening.cover .(3).1.tapped.entry.for.n°.13.(Pg.13 .5).cable.gland ..For.ISO.M20.use.adaptor.DE9RP13520 .
Dimensions Detection solutionsRopepullswitchesXY2CB
1
2
3
4
5
6
7
8
9
10
16
1.0 1.0
Index Product reference index
9001KP1R9 14
9001KP7R9 14
9001KP35R9 14
DDE9RP13520 14
DL1AA024 10
DL1AA127 10
DL1AA220 10
DL1CB006 14
DL1CE024 14
QQ99900901 10
Q99900911 10
X
XY2CB10 13
XY2CB11 13
XY2CB12 13
XY2CB13 13
XY2CB14 13
XY2CB20 13
XY2CB21 13
XY2CB22 13
XY2CB23 13
XY2CB24 13
XY2CB30 13
XY2CB31 13
XY2CB32 13
XY2CB33 13
XY2CB34 13
XY2CB104 13
XY2CB204 13
XY2CB304 13
XY2CE1A250 6
XY2CE1A270 6
XY2CE1A296 6
XY2CE1A297 6
XY2CE1A450 6
XY2CE1A470 6
XY2CE2A250 6
XY2CE2A270 6
XY2CE2A296 6
XY2CE2A297 6
XY2CE2A450 6
XY2CE2A470 6
XY2CH13170 6
XY2CH13190 6
XY2CH13250 6
XY2CH13253 6
XY2CH13270 6
XY2CH13273 6
XY2CH13290 6
XY2CH13293 6
XY2CH13350 6
XY2CH13370 6
XY2CH13390 6
XY2CH13450 6
XY2CZ0024 10
XY2CZ102 9
XY2CZ105 9
XY2CZ107 9
XY2CZ0130 10
XY2CZ203 9
XY2CZ0230 10
XY2CZ301 9.14
XY2CZ302 9.14
XY2CZ303 9
XY2CZ305 14
XY2CZ310 14
XY2CZ402 9.14
XY2CZ404 9.14
XY2CZ503 9.14
XY2CZ513 9.14
XY2CZ523 9.14
XY2CZ524 9
XY2CZ601 9.14
XY2CZ602 9.14
XY2CZ701 9.14
XY2CZ703 9
XY2CZ704 9
XY2CZ705 9.14
XY2CZ707 14
XY2CZ708 9
XY2CZ800 10
XY2CZ801 10
XY2CZ804 9
XY2CZ805 10
XY2CZ908 10
XY2CZ918 9
XY2CZ1015 9
XY2CZ3015 914
XY2CZ9310 9
XY2CZ9315 9
XY2CZ9330 9
XY2CZ9525 9
XY2CZ9550 9
XY2CZ9570 9
ZZALVB4 10
ZALVB5 10
ZALVG4 10
ZALVG5 10
ZALVM4 10
ZALVM5 10
ZB5AA639 10
ZB5AC64 10
ZB5AG6R26 10
ZB5AG612R26 10
ZB5AP6 10
ZB5AP6S 10
ZB5AZ901 10
ZB5AZ905 10
Theinformationprovidedinthisdocumentationcontainsgeneraldescriptionsand/ortechnicalcharacteristicsoftheperformanceoftheproductscontainedherein.Thisdocumentationisnotintendedasasubstituteforandisnottobeusedfordeterminingsuitabilityorreliabilityoftheseproductsforspecificuserapplications.Itisthedutyofanysuchuserorintegratortoperformtheappropriateandcompleteriskanalysis,evaluationandtestingoftheproductswithrespecttotherelevantspecificapplicationorusethereof.NeitherSchneiderElectricnoranyofitsaffiliatesorsubsidiariesshallberesponsibleorliableformisuseoftheinformationcontainedherein.