66
EMERGENCY BALLAST WIRING GUIDE rev. 103103

EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

Embed Size (px)

Citation preview

Page 1: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

EMERGENCY BALLASTWIRING GUIDE

rev. 103103

Page 2: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

7/8" BUSHING PLASTIC TUBE

INDICATOR LIGHT

BALLAST CHANNELCOVER

FLEX CONDUIT

FIXTURE LENS

FLEX “A”

JUNCTIONBOX

CEILINGTILE

A.C. BALLAST &LAMP SOCKET COMPARTMENT

FLEX “B”

SWITCH BOX

TEST SWITCH

CHARGE LIGHT

BLACK

YELLOWYELLOWWHITE

UNSWITCHED

SWITCHED ORUNSWITCHEDLINE

COMMON

BLK (120V)

WHITE

*LAMP

*AC / EMERGENCY

BLACKWHITE

BLUE

RED

BLUEBLUE/WHTRED/WHT

REDYELLOW

UNITCONNECTOR

LPTS / CHARGEINDICATOR

COMMON

A.C.Ballast

EMERGENCYBALLAST

RELAY

HOW TO USETHE EMERGENCY BALLAST WIRING GUIDE

This Document has been customized to contain a wide library of individual dia-grams for various installation applications. If a diagram cannot be found withinthis selection, consult Customer Service.

The diagrams are categorized primarily according to the number of lamps in thefixture, then followed by the ballast type. Sometimes a specific lamp type islisted (i.e: biax, circline, etc.). If a lamp type is not listed, the diagram shows atypical straight tube lamp configuration. In some cases, a specific ballast manu-facturer is listed for AC ballasts that have unique wiring arrangements.

Diagrams for specific situations can be located within this PDF file by using thefollowing methods:

1) USING THE NAVIGATION WINDOWUse the Navigation window and select the Emergency Ballast for which thediagram is needed, then scroll through the list of applications to find thediagram(s) that meet the necessary criteria by clicking on the “plus” sign next tothe Unit Model. (Many of the diagrams are bookmarked with identical descrip-tions. Examine the diagram for details as to whether or not it applies to yoursituation.)

NOTE: The order in which the pages are bookmarked is not indicative of theactual page order, therefore, continuing to the next page after a “Two LampBallast” diagram may not necessarily take you to another “Two Lamp Ballast”diagram. To aid in locating specific diagrams, each has been bookmarked andcategorized in the navigation window.

2) USING THE FIND COMMANDSome diagrams feature a Model List for reference. If you know the actual modelnumber of the AC ballast that the emergency unit is being wired to, you may usethe “FIND” tool in the toolbar (Denoted by the binocular icon) to search thediagrams for that particular model. FIND commands may or may not be suc-cessful, since not all ballasts models are listed within this file.

When using the FIND command, it may be helpful to search for only the first fewletters or numbers of the model number (i.e. “RCN” or “ECO”) due to the natureof how the reference lists are compiled. Include any hyphens or slashes thatmay appear in the model number when using the FIND command.

This Guide is by no means an exhaustive record of all AC Ballast/EmergencyUnit combinations. If a search using the FIND command or Navigation windowis not successful, contact Customer Service for further assistance.

You may request an updated Wiring Diagram Guide at anytime. Please consultCustomer Service to find out if a later version with any additions and/or correc-tions is available.

FIXTURE

Page 3: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C1 C1

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1LR

SB

ON

E L

AM

P R

AP

ID S

TAR

T B

AL

LA

ST

MOTOROLAM1-RL-T8-1LL-A-120/277M1-RL-T8-050-D-120M1-RN-T12-1LL-B-120/277M1-RN-T8-10C-B-120/277M1-RN-T8-1LL-D-120/277M1-RV-T8-001-B-120

ADVANCEHM/VM-1P30-TPHM/VHM-1P20-TPLQ/VLQ-106F-TPPR/V-1P817-TPR/V-1P825-TPR/V-1P32-TPR/V-1P840-TPR/V-140-TPR/V-1U40P-TPRC/VC-160-TPRC/VC-1P40-TPRCN/VCN-1S32RCN/VCN-1S40REL/VEL-1S40-RH-TPRK/VK-132-TPRK/VK-134-TPRS/VS-160-TPREZ-132RIC/VIC-132-TPRIC/VIC-140-TPRZT/VZT-132*

LUTRONECO-T832-120/277-1*FDB-4827-120/277-1*

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

EBTECG-120/277-1/40 SRSSB1-120/277-1/40 LHGE

G1-RL-T8-1LL-120/277G1-RN-T8-10C-120/277G1-RN-T8-1LL-120/277G1-RN-T12-1LL-120/277

KINGTEC

132K120/277

Page 4: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

C2 C2

LUTRONECO-T832-120/277-2*FDB-4827-120/277-2*

MOTOROLAM2-RH-T8-1LL-B-120/277M2-RL-T8-1LL-A-120/277M2-RN-T12-1LL-B-120/277M2-RN-T8-10C-B-120/277M2-RN-T8-1LL-D-120/277

ADVANCEHM/VM-2SP20-TPLQ-206F-TPR/V-2P817-TPR/V-2P825-TPR/V-2P832-TPR/V-2P840-TPR/V-2S40-TPR/V-2SP30-TPRC/VC-2SP40-TPRC/VC-2S85-TP/FO/RORC/VC-2S110-FO/RORCN/VCN-2S32RCN/VCN-2S40RC-2SP830-TPREL/VEL-2S40-RH-TPRL-2SP20-TPRM-2S35-TPRM/VM-2SP30-TPRIC/VIC-2S32RIC/VIC-2S40-TPREZ/VEZ-2S32RK/VK-2S32-TPRK/VK-2S34-TPRK/VK-2S40-TPRK/VK-2S110-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

MAGNETEKB232 R277 HP

EBT

ECG-120/277-2/32 SRECG-120/277-2/40 SRSSB1-120/277-2/32 LHSSB1-120/277-2/40 LH /-(75%)/-(MPX)SSB7-120/277-2/32 LH

GEG2-RH-T8-1LL-120/277G2-RL-T8-1LL-120/277G2-RN-T8-10C-120/277G2-RN-T8-1LL-120/277G2-RN-T12-1LL-120/277

MAGNETEKGB 2x32/FL/R/VHP

KINGTEC232K120/277232KI20-75%232K2120240K120/277

Page 5: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

LPT

S /

CH

AR

GE

IND

ICA

TO

R

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E/W

HT

BLU

E/W

HT

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W UN

ITC

ON

NE

CT

OR

CO

MM

ON

➀A

.C.

Bal

last

BLU

EB

LUE

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

3LR

SB

TH

RE

E L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

C3 C3

ADVANCER/V-3S34-TPRCN/VCN-3S32RCN/VCN-3S40REL/VEL-3S40-RH-TPRIC/VIC-3S32-TPRIC/VIC-3S40-TPRL-3SP20-TPRK/VK-3S34-TPRZT/VZT-3S32*REZ/VEZ-3S32*

MOTOROLA

M3-RL-T8-1LL-A-120/277M3-RN-T12-1LL-B-120/277M3-RN-T8-1LL-A-120/277

LUTRONECO-T832-120/277-3*FDB-4827-120/277-3*

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

EBTSSB1-120/277-3/32 LHSSB1-120/277-3/40 LHGE

G3-RL-T8-1LL-120/277G3-RN-T8-10C-120/277G3-RN-T8-1LL-120/277G3-RN-T12-1LL-120/277

Page 6: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

RE

D

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

1LIS

B

EM

ER

GE

NC

YB

AL

LA

ST

C4 C4

B132I120/277HPB132I120/277RH

M1-IN-T8-1LL-D-120/277M1-IN-T8-D-120/277M1-IN-T8-GP-D-120/277

ADVANCE

RCN/VCN-1P32REL/VEL-1P32-RH-TPREL/VEL-1P32-SC

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

ECG-120/277-1/32 PISSB2-120/277-1/32 IS LH

G1-IN-T8-120/277

EBT

GE

MAGNETEK

MOTOROLA

GB 1x32/FL/I/120-277GB 1x32/FL/I/120L-277L

GOLDSTAR

HOWARDE1/32IS-120/277EC1/32IS-120/277ECL1/32IS-120/277EL1/32IS-120/277

KINGTEC132K120-IS/277-IS

Page 7: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

RE

D➂

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

.

EM

ER

GE

NC

YB

AL

LA

ST

2LIS

B

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

C5 C5

Page 8: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

BLU

E

RE

D

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

EM

ER

GE

NC

YB

AL

LA

ST

2LIS

B2

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

C6 C6

MOTOROLAM2-IN-T8-D-120/277M2-IN-T8-1LL-D-120/277M2-IL-T8-GP-D-120/277M2-IN-T8-GP-D-120/277

ADVANCERCN/VCN-2P32 /(-LW)REL/VEL-2P17-RH-TPREL/VEL-2P32-LW-RH-TPREL/VEL-2P32-RH-TPREL/VEL-2P32-SC

MAGNETEK

B232I120/277HPB232I120/277RH

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

EBTECG-120/277-2/32 PISSB2-120/277-2/17 IS LHSSB2-120/277-2/32 IS LHSSB2-120/277-2/32 IS MPX LH

GE

G2-IN-T8-120/277

GOLDSTARGB 2x32/FL/I/120-277GB 2x32/FL/I/120L-277LGB 2x32/FL/I/120HBF-277HBF

HOWARDE2/32IS-120/277EC2/32IS-120/277

KINGTEC

232K120-IS/277-IS

Page 9: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

BLU

E

BLU

E

RE

D

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➂E

ME

RG

EN

CY

BA

LL

AS

T

3LIS

B

TH

RE

E L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

C7 C7

ADVANCE

RCN/VCN-3P32REL/VEL 3P32-RH-TPREL/VEL 3P32-LW-RH-TP

MOTOROLA

M3-IL-T8-GP-A-120/277M3-IN-T8-A-120/277M3-IN-T8-D-120/277M3-IN-T8-GP-A-120/277

MAGNETEK

B332I120/277RHB332I120/277HP

EBTSSB2-120/277-3/32 IS LH

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

GEG3-IN-T8-120/277

GOLDSTARGB 3x32/FL/I/120-277GB 3x32/FL/I/120L-277L

HOWARDE3/32IS-120/277EC3/32IS-120/277ECL3/32IS-120/277EL3/32IS-120/277

Page 10: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

LAM

P

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D

RE

D

BLU

EB

LUE

YE

LLO

W

YE

LLO

W

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➂E

ME

RG

EN

CY

BA

LL

AS

T

4LIS

B

FO

UR

LA

MP

INS

TA

NT

ST

AR

T B

AL

LA

ST

C8 C8

MAGNETEK

B432I120/277HPB432I120/277RHMOTOROLAM4-IL-T8-GP-A-120/277M4-IN-T8-A-120/277M4-IN-T8-D-120/277M4-IN-T8-GP-A-120/277

ADVANCE

RCN/VCN-4P32REL/VEL-4P32-RH-TPREL/VEL-4P32-LW-RH-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

EBT

SSB2-120/277-4/32 IS LH /-(75%)GEG4-IN-T8-120/277

GOLDSTAR

GB 4x32/FL/I/120-277GB 4x32/FL/I/120L-277LHOWARDE4/32IS-120/277EC4/32IS-20/277KINGTEC432K120-IS/277-IS432K120-75%

Page 11: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C9 C9

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

RE

D

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P B

IAX

1LB

X

EM

ER

GE

NC

YB

AL

LA

ST

BLU

E

CA

P U

NU

SE

D L

EA

D➃

MAGNETEKC240I120/277RH

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 12: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C10 C10

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1BX

LRS

B

ON

E B

IAX

LA

MP

RA

PID

STA

RT

BA

LL

AS

T

*LA

MP

MOTOROLA

M1-RL-T8-1LL-A-120/277M1-RL-T8-050-D-120M1-RN-T12-1LL-B-120/277M1-RN-T8-10C-B-120/277M1-RV-T8-001-B-120

ADVANCE

R/V-1BP27-TPR/V-1BP39-TPR/V-1BP40-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 13: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C11 C11

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1BX

LRS

B_D

M

ON

E B

IAX

LA

MP

RA

PID

STA

RT

BA

LL

AS

T

*LA

MP

DIM

ME

D H

OT

LUTRONECO-T540-120/277-1

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 14: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

2BX

LRS

B_D

M

*LA

MP

LAM

P

YE

LLO

W

YE

LLO

W

TW

O B

IAX

LA

MP

RA

PID

STA

RT

BA

LL

AS

T

C12 C12

GEG2-RN-T5/40-ILL-120/277

MOTOROLAM2-RN-T5/40-1LL-B-120/277M2-RH-T8-1LL-B-120/277M2-RL-T8-1LL-A-120/277M2-RN-T12-1LL-B-120/277M2-RN-T8-10C-B-120/277M2-RN-T8-1LL-D-120/277

ADVANCER/V-2BS27-TPR/V-2BS39-TPR/V-2BS40-TP

EBTSSB1-120/277-2/39 TT LHSSB1-120/277-2/40 TT LH /-(75%)

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

LUTRON

ECO-T540-120/277-2

Page 15: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C13 C13

MOTOROLA

M4-RL-T8-1LL-A-120/277M4-RL-T8-1LL-B-120/277M4-RN-T8-1LL-A-120/277M4-RN-T8-1LL-B-120/277

LPT

S /

CH

AR

GE

IND

ICA

TO

R

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E/W

HT

BLU

E/W

HT

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W UN

ITC

ON

NE

CT

OR

CO

MM

ON

➀A

.C.

Bal

last

BLU

EB

LUE

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

FO

UR

LA

MP

RA

PID

ST

AR

T B

AL

LA

ST

4LR

SB

EM

ER

GE

NC

Y

BA

LL

AS

T

*LA

MP

LAM

P

LAM

P

BR

OW

NB

RO

WN

ADVANCE

RC-4S60-TPRC-4S85-TPVCN-4S32-SC

GEG4-RL-T8-1LL-120/277G4-RN-T8-10C-120/277G4-RN-T8-1LL-120/277

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 16: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C14 C14

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

27

7V

)

BL

K (

12

0V

)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BL

AC

K

WH

ITE

BL

UE

BL

UE

BL

UE

/WH

TR

ED

/WH

TR

ED

YE

LL

OW

UN

ITC

ON

NE

CT

OR

LP

TS

/ C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

➀ ➁ ➂

➀A

.C.

Balla

stR

ED

SE

LE

CT

PR

OP

ER

VO

LT

AG

ELE

AD

. C

AP

UN

US

ED

LE

AD

.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LL

AT

ION

IS

CO

MP

LE

TE

AN

D

AC

PO

WE

R I

S S

UP

PLIE

D.

CO

NN

EC

T B

LU

E/W

HT

AN

D R

ED

/WH

TW

IRE

S T

OG

ET

HE

R

TW

O B

IAX

LA

MP

IN

ST

AN

T S

TA

RT

BA

LL

AS

T

2LIS

BX

EM

ER

GE

NC

YB

AL

LA

ST

BL

UE

LA

MP

MAGNETEK

B232I120/277HPB232I120/277RH

MOTOROLA

M2-IL-T8-GP-120/277M2-IN-T8-D-120/277M2-IN-T8-1LL-D-120/277M2-IN-T8-GP-120/277

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 17: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C15 C15

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

27

7V

)

BL

K (

12

0V

)

WH

ITE

LA

MP

*LA

MP

*AC

/ E

ME

RG

EN

CY

BL

AC

KW

HIT

E

BL

UE

RE

D

YE

LL

OW

BL

UE

BL

UE

/WH

TR

ED

/WH

TR

ED

YE

LL

OW

UN

ITC

ON

NE

CT

OR

LP

TS

/C

HA

RG

E I

ND

ICA

TO

RC

OM

MO

N

➀A

.C.

Ba

llast

TW

O L

AM

P B

AL

LA

ST

➀ ➁ ➂

SE

LE

CT

PR

OP

ER

VO

LT

AG

EL

EA

D.

CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LL

AT

ION

IS

CO

MP

LE

TE

AN

D

AC

PO

WE

R I

S S

UP

PL

IED

.C

ON

NE

CT

BL

U/W

HT

AN

D R

ED

/WH

TW

IRE

S T

OG

ET

HE

R

YE

LL

OW

EM

ER

GE

NC

Y

BA

LL

AS

T

2LM

B

Page 18: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C16 C16

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

CH

AR

GE

IND

ICA

TO

R/L

PT

SC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P M

AG

NE

TIC

BA

LL

AS

T

EM

ER

GE

NC

YB

AL

LA

ST

1LM

B

Page 19: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

2

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

C17 C17

MAGNETEKBT5-228/120BT5-228/277

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

SYLVANIAQT2X54PHO/120PHOQT2X54PHO/277PHO

Page 20: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C18 C18

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

E

WH

ITE

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

lastO

NE

LA

MP

CIR

CL

INE

RA

PID

ST

AR

T B

AL

LA

ST

EM

ER

GE

NC

YB

AL

LA

ST

1LC

RS

B

RLCS-140-TPRLQS-122-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

ADVANCE

Page 21: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

LPT

S /

CH

AR

GE

IND

ICA

TO

R

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W UN

ITC

ON

NE

CT

OR

CO

MM

ON

➀A

.C.

Bal

last

BLU

E

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

3LR

SB

TW

O L

AM

P C

IRC

LIN

E R

AP

ID S

TA

RT

BA

LLA

ST

*LA

MP

YE

LLO

WY

ELL

OW

BLU

E

C19 C19

Page 22: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C20 C20

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1LLA

G

ON

E L

AM

P L

AG

BA

LL

AS

T

DIS

CO

NN

EC

T L

AM

P H

OLD

ER

MAGNETEK543-B

ADVANCERL-140-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 23: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C21 C21

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1LP

HS

B

ON

E L

AM

P P

RE

-HE

AT

STA

RT

BA

LL

AS

T

PF

CC

APA

CIT

OR

S

Page 24: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

EM

ER

GE

NC

YB

AL

LA

ST

2ES

LIS

B2

EN

ER

GY

SA

VIN

GS

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

YE

LLO

W

C22 C22

ENERGY SAVINGSES-2/I-1B-32/25/17/15-UNV-A-IS

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 25: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

➀ ➁

ON

E L

AM

P E

ME

RG

EN

CY

ON

LY

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

CA

P O

FF

LEA

DS

EM

ER

GE

NC

Y

BA

LL

AS

T

1LE

OC23 C23

Page 26: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

RE

D

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P T

RIA

D B

AL

LA

ST

1LT

B

EM

ER

GE

NC

YB

AL

LA

ST

BLU

E

C24 C24

TRIAD

B240I 120/277

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 27: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C25 C25

FULHAMWH4-120-LWH4-277-LWH5-120-LWH5-277-LWH6-120-LWH6-277-L

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LAMP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

➀ ➁ ➂

➀A

.C.

Bal

last

YE

LLO

W

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

FU

LH

AM

WO

RK

HO

RS

E B

AL

LA

ST

FW

B

EM

ER

GE

NC

YB

AL

LA

ST

RE

D

LAMP

LAMP

RE

D

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 28: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

ATE

CO

NN

EC

TOR

UN

TIL

INS

TALL

ATI

ON

IS C

OM

PLE

TE A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

THE

R

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (2

77V

)

BLK

(120

V)

WH

ITE

LAM

P

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

BLU

E

BLU

E

YE

LLO

WB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

D

YE

LLO

W

UN

ITC

ON

NE

CTO

R

LPTS

/ C

HA

RG

EIN

DIC

ATO

R

CO

MM

ON

➀A

.C.

Bal

last

THR

EE

LA

MP

INS

TAN

T S

TAR

T B

ALL

AS

T

3LIS

B2

EM

ER

GE

NC

Y

BA

LLA

ST

C26 C26

EM

ER

GE

NC

Y

BA

LL

AS

T

VCN 3P32ADVANCE

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 29: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C27 C27

LP

TS

/ C

HA

RG

EIN

DIC

AT

OR

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(120V

)

WH

ITE

LA

MP

LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E/W

HT

BLU

E/W

HT

RE

DR

ED

YE

LLO

WY

ELLO

W

BLU

EB

LU

E/W

HT

RE

D/W

HT

RE

DY

ELLO

W UN

ITC

ON

NE

CT

OR

CO

MM

ON

➀A

.C.

Balla

stB

LU

EB

LU

E

SE

LE

CT

PR

OP

ER

VO

LT

AG

ELE

AD

. C

AP

UN

US

ED

LE

AD

.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LE

TE

AN

D

AC

PO

WE

R IS

SU

PP

LIE

D.

➀ ➁

TH

RE

E L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

3LR

SB

2

EM

ER

GE

NC

Y

BA

LL

AS

T

*LA

MP

Page 30: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C28 C28

B332-R277HPB332-R120HP

LPT

S /

CH

AR

GE

IND

ICA

TO

R

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D/W

HT

RE

D/W

HT

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W UN

ITC

ON

NE

CT

OR

CO

MM

ON

➀A

.C.

Bal

last

BLU

EB

LUE

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

TH

RE

E L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

3LR

SB

3

EM

ER

GE

NC

Y

BA

LL

AS

T

*LA

MP

MAGNETEK

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 31: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C29 C29

B432 R277 HP

LP

TS

/ C

HA

RG

EIN

DIC

AT

OR

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

27

7V

)

BL

K (

12

0V

)

WH

ITE

LA

MP

*AC

/ E

ME

RG

EN

CY

BL

AC

KW

HIT

EB

LU

E/W

HT

BL

UE

/WH

T

RE

DR

ED

YE

LL

OW

/BL

KY

EL

LO

W/B

LK

BL

UE

BL

UE

/WH

TR

ED

/WH

TR

ED

YE

LL

OW

UN

ITC

ON

NE

CT

OR

CO

MM

ON

A.C

.B

alla

stB

LU

EB

LU

E

SE

LE

CT

PR

OP

ER

VO

LT

AG

EL

EA

D.

CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LL

AT

ION

IS

CO

MP

LE

TE

AN

D

AC

PO

WE

R I

S S

UP

PL

IED

.

➀ ➁

FO

UR

LA

MP

RA

PID

ST

AR

T B

AL

LA

ST

4L

RS

B2

EM

ER

GE

NC

Y

BA

LL

AS

T

*LA

MP

LA

MP

LA

MP

YE

LL

OW

RE

D/W

HT

RE

D/W

HT

YE

LL

OW

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

MAGNETEK

Page 32: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C30 C30

ECO-T832-120/277-2*FDB-4827-120/277-2*

M2-RH-T8-1LL-B-120/277M2-RL-T8-1LL-A-120/277M2-RN-T12-1LL-B-120/277M2-RN-T8-10C-B-120/277M2-RN-T8-1LL-D-120/277

RIC/VIC-2S32REZ/VEZ-2S32RZT/VZT-2S32*

B232 R277 HP

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

A.C

.B

alla

stE

ME

RG

EN

CY

BA

LLA

ST

2LR

SB

WR

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

TW

ITH

RE

LA

Y

RE

LAY

BLA

CK

YE

LLO

WY

ELL

OW

WH

ITE

UN

SW

ITC

HE

D

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

ADVANCE

LUTRON

MAGNETEK

MOTOROLA

Page 33: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C31 C31

WH3

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

lastON

E L

AM

P C

IRC

LIN

E IN

ST

AN

T S

TA

RT

BA

LL

AS

T

EM

ER

GE

NC

YB

AL

LA

ST

1LC

ISB

_F

YE

LLO

W

FULLHAM

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 34: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C32 C32

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

➀ ➁

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

ON

E L

AM

P R

AP

ID S

TAR

T B

AL

LA

ST

1LR

SB

_2

EM

ER

GE

NC

YB

AL

LA

ST

Page 35: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C33 C33

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

➀ ➁

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

EM

ER

GE

NC

YB

AL

LA

ST

2LR

SB

_3

TW

O L

AM

P R

AP

ID S

TAR

T B

AL

LA

ST

Page 36: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C34 C34

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

RE

D/W

HT

RE

D

YE

LLO

W

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

TH

RE

E L

AM

P IN

STA

NT

STA

RT

BA

LL

AS

T

3LIS

B_3

EM

ER

GE

NC

YB

AL

LA

ST

BLA

CK

/WH

T

(GR

D)

ES-4/3-T8-32/25/17-UNV-B-IS

ENERGY SAVINGS

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 37: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C35 C35

BLA

CK

YE

LLO

WY

ELL

OW

WH

ITE

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

RE

D

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

A.C

.B

alla

stE

ME

RG

EN

CY

BA

LLA

ST

1LIS

BW

R

ON

E L

AM

P IN

STA

NT

STA

RT

BA

LL

AS

TW

ITH

RE

LA

Y

RE

LAY

Page 38: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C36 C36

BLA

CK

YE

LLO

WY

ELL

OW

WH

ITE

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

A.C

.B

alla

stE

ME

RG

EN

CY

BA

LLA

ST

1LR

SB

WR

ON

E L

AM

P R

AP

ID S

TAR

T B

AL

LA

ST

WIT

H R

EL

AY

RE

LAY

Page 39: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

YE

LLO

W

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P IN

ST

AN

T S

TA

RT

FU

LL

HA

M B

AL

LA

ST

1LIS

B_F

EM

ER

GE

NC

YB

AL

LA

ST

RE

D

4

4C

AP

UN

US

ED

LE

AD

C37 C37

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

FULLHAMWORKHORSE IV

Page 40: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C38 C38

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (2

77V

)

BLK

(120

V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

RE

D

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CTO

R

CH

AR

GE

IND

ICA

TOR

/LP

TSC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

ATE

CO

NN

EC

TOR

UN

TIL

INS

TALL

ATI

ON

IS C

OM

PLE

TE A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

THE

R

TWO

LA

MP

SER

IES

LEA

D B

ALL

AST

EMER

GEN

CY

BA

LLA

ST

2LSL

BR

N O

R Y

EL

BR

N O

R Y

EL

ADVANCE

VSM-2E75S5-TP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 41: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

3

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

YE

L/W

HT

C39 C39

SYLVANIAQT2X54PHO/277PHO-DIM

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 42: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D

BLU

E

YE

LLO

W

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

EM

ER

GE

NC

Y

BA

LL

AS

T

2LIS

BE

SI

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

C40 C40

ENERGY SAVINGS

ES-2/1-T8-32/25/17/15-UNV-A-IS

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 43: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C41 C41

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

1LP

HS

B_2

ON

E L

AM

P P

RE

-HE

AT

STA

RT

BA

LL

AS

T

S

ADVANCE

LC-14-20-C

Page 44: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C42 C42

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

*LAMP

LAMP

LAMP

TH

RE

E B

IAX

RA

PID

ST

AR

T B

AL

LA

ST

RED/WHITERED/WHITE

YE

LLO

WY

ELL

OW

3BX

LRS

B

RE

DR

ED

B340-R120 HPB340-R277 HP

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

MAGNETEK

Page 45: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

A.C

.B

alla

st

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

BR

OW

N

RE

DR

ED

/BLU

YE

LLO

W

BR

OW

NB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

D

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

_AC

E

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

*LA

MP

YE

LLO

W

1 2 3 4 5 6 7

1 245

1 3

C43 C43ANTRON / ACEEPD-A54T5

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 46: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

A.C

.B

alla

st

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

E

BR

OW

N

RE

D/B

LU

YE

LLO

W

BR

OW

NB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

D UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

1LR

SB

_AC

E

ON

E L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

*LA

MP

1 2 3 4 5 6 7

1 3

C44 C44ANTRON / ACEEPD-A54T5

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 47: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D

RE

D

YE

LLO

W

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

EM

ER

GE

NC

YB

ALL

AS

T

2LIS

B2_

F

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LLA

ST

C45 C45

FULLHAMWORKHORSE 3WORKHORSE 4

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 48: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C46 C46

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

➀ ➁ ➂

➀A

.C.

Bal

last

YE

LLO

W

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

E/W

HT

AN

D R

ED

/WH

TW

IRE

S T

OG

ET

HE

R

TW

O B

IAX

LA

MP

INS

TA

NT

ST

AR

T F

UL

LH

AM

BA

LL

AS

T

2LIS

BX

_FB

EM

ER

GE

NC

YB

AL

LA

ST

RE

D

LAM

P

FULLHAM

WORKHORSE IV

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 49: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

1LIS

B_2

EM

ER

GE

NC

YB

AL

LA

ST

C47 C47

Page 50: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C48 C48

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D

BLU

E

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

CH

AR

GE

IND

ICA

TO

R/L

PT

SC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

BR

OW

N

TW

O L

AM

P S

ER

IES

LE

AD

BA

LL

AS

T

EM

ER

GE

NC

Y

BA

LL

AS

T

2LS

L_2

BR

OW

N

MAGNETEK

827-SLH-TC-P

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 51: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C49 C49

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

CH

AR

GE

IND

ICA

TO

R/L

PT

SC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

TW

O L

AM

P S

ER

IES

LE

AD

BA

LL

AS

T

EM

ER

GE

NC

Y

BA

LL

AS

T

2LS

L_3

RE

D

BLU

E

Page 52: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C50 C50

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

➀ ➁ ➂

➀A

.C.

Bal

last

RE

D

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

E/W

HT

AN

D R

ED

/WH

TW

IRE

S T

OG

ET

HE

R

TW

O U

-BE

NT

LA

MP

INS

TA

NT

ST

AR

T B

AL

LA

ST

2LIS

U

EM

ER

GE

NC

YB

AL

LA

ST

BLU

E

LAM

P

Page 53: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

2BX

LRS

B2

*LA

MP

LAM

P

YE

LLO

W

YE

LLO

W

TW

O B

IAX

RA

PID

STA

RT

C51 C51

Page 54: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

YE

LLO

W

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P IN

ST

AN

T S

TA

RT

FU

LL

HA

M B

AL

LA

ST

1LIS

B_F

2

EM

ER

GE

NC

YB

AL

LA

ST

RE

D

C52 C52

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

FULLHAMWORKHORSE 3

Page 55: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

FW

5B

*LA

MP

LAM

P

YE

LLO

W

FU

LL

HA

M W

OR

KH

OR

SE

BA

LL

AS

T

RE

DR

ED

C53 C53

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

FULLHAM

WORKHORSE 5

Page 56: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C54 C54

UN

SW

ITC

HE

D L

INE

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

A.C

.B

alla

stE

ME

RG

EN

CY

BA

LLA

ST

1LR

SB

WT

S

ON

E L

AM

P R

AP

ID S

TAR

T B

AL

LA

ST

WIT

H T

ES

T S

WIT

CH

TE

ST

S

WIT

CH

BLA

CK

RE

D

BLA

CK

RE

D

Page 57: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

FW

5BC

YE

LLO

W

FU

LL

HA

M W

OR

KH

OR

SE

BA

LL

AS

TW

ITH

TW

O C

IRC

LIN

E L

AM

PS

RE

DR

ED

LAM

P

LAM

P

C55 C55

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

FULLHAM

WORKHORSE 5

Page 58: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

WT

S

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

TW

ITH

TE

ST

SW

ITC

H

UN

SW

ITC

HE

D L

INE

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

TE

ST

S

WIT

CH

BLA

CK

RE

D

BLA

CK

RE

D

C56 C56

Page 59: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

YE

LLO

WY

ELL

OW

BLU

EY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

➀A

.C.

Bal

last

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

4

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

BLU

E

YE

LLO

W

C57 C57

ELBAERP-232-L

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 60: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

➂U

NS

WIT

CH

ED

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

DY

ELL

OW U

NIT

CO

NN

EC

TO

R

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀ ➁ ➂

➀A

.C.

Bal

last

RE

D

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

ON

E L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

TW

ITH

347

V C

ON

VE

RT

ER

1LIS

B_3

47

EM

ER

GE

NC

YB

AL

LA

ST

347

VO

LTC

ON

VE

RT

ER

C58 C58

Page 61: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C59 C59

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

YE

LLO

WY

ELL

OW

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

lastO

NE

LA

MP

CIR

CL

INE

RA

PID

ST

AR

T B

AL

LA

ST

EM

ER

GE

NC

YB

AL

LA

ST

1LC

RS

B_2

Page 62: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

C60 C60

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

BLU

EB

LUE

RE

D

RE

D

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S/C

HA

RG

EIN

DIC

AT

OR

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

lastO

NE

LA

MP

CIR

CL

INE

RA

PID

ST

AR

T B

AL

LA

ST

EM

ER

GE

NC

YB

AL

LA

ST

1LC

RS

B_3

Page 63: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*LA

MP

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

D

RE

D

YE

LLO

W

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

RC

OM

MO

N

➀A

.C.

Bal

last

➀ ➁ ➂

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.C

ON

NE

CT

BLU

/WH

T A

ND

RE

D/W

HT

WIR

ES

TO

GE

TH

ER

EM

ER

GE

NC

YB

AL

LA

ST

2LIS

B3_

F

TW

O L

AM

P IN

ST

AN

T S

TA

RT

BA

LL

AS

T

C61 C61

FULLHAMWORKHORSE 4

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 64: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

A.C

.B

alla

st

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

YE

LLO

WB

LUE

BLU

E/W

HT

RE

D/W

HT

RE

D UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

ALL

AS

T

2LR

SB

_AC

E_2

TW

O L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

*LA

MP

1 2 3 4 5 6 7

124 53 4

C62 C62ANTRON / ACEEPD-B54T5

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 65: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

A.C

.B

alla

st

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

LAM

P

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

YE

LLO

W

BLU

EB

LUE

/WH

T

RE

D/W

HT

RE

D UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

EM

ER

GE

NC

YB

AL

LA

ST

1LR

SB

_AC

E_2

ON

E L

AM

P R

AP

ID S

TA

RT

BA

LL

AS

T

1 2 3 443

C63 C63ANTRON / ACEEPD-B54T5

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

Page 66: EMERGENCY BALLAST WIRING GUIDE - LightAlarms · c1 c1 switched or unswitched line unswitched common org (277v) blk (120v) white *lamp *ac / emergency black white blue blue red red

UN

SW

ITC

HE

D

SW

ITC

HE

D O

RU

NS

WIT

CH

ED

LIN

E

CO

MM

ON

OR

G (

277V

)

BLK

(12

0V)

WH

ITE

*AC

/ E

ME

RG

EN

CY

BLA

CK

WH

ITE

RE

DR

ED

BLU

EB

LUE

/WH

TR

ED

/WH

TR

ED

YE

LLO

W

UN

ITC

ON

NE

CT

OR

LPT

S /

CH

AR

GE

IND

ICA

TO

R

CO

MM

ON

SE

LEC

T P

RO

PE

R V

OLT

AG

ELE

AD

. CA

P U

NU

SE

D L

EA

D.

DO

NO

T M

AT

E C

ON

NE

CT

OR

UN

TIL

INS

TA

LLA

TIO

N IS

CO

MP

LET

E A

ND

A

C P

OW

ER

IS S

UP

PLI

ED

.

➀ ➁

➀A

.C.

Bal

last

EM

ER

GE

NC

YB

ALL

AS

T

FW

5B_2

*LA

MP

LAM

P

YE

LLO

W

FU

LL

HA

M W

OR

KH

OR

SE

BA

LL

AS

T

RE

DR

ED

➂C

AP

UN

US

ED

LE

AD

S

C64 C64

ALL COMPATIBLE BALLASTS MAY NOT BE LISTED.*DIMMING CONTROL WIRES ARE NOT AFFECTED BYEM PACK

FULLHAMWORKHORSE 5