5
www.tridonic.com 1 Subject to change without notice. Data sheet 10/14-832-11 HID control gear Electronic Product description • Pulse packets for increased ignition energy (pulseCONTROL technology) • Flicker-free light • Colour stability thanks to constant power • No acoustic resonance • Safety shutdown if a lamp is faulty or missing • Greatly reduced reignition time • Hardly any EMC interference in the ignition phase • Screw terminals: ≤ 1.5 mm² for stranded wire, ≤ 2.5 mm² for solid wire • Dimming via digital interface • Noise-free precise control via DALI, DSI or stepDIM • Fault reporting in DALI mode • Unit fully encased to protect against dust, moisture and vibration • Enhanced protection against mains transients • Enhanced insulation • Casing: polycarbonate, black Technical data Mains voltage range 220 – 240 V AC voltage range 198 – 254 V Mains frequency 50 / 60 Hz λ at 50 Hz 230 V 0.97 Max. ignition voltage PCI, PCIS 5 kVp Max. ignition voltage PCS 2.5 kVp Operating frequency 145 Hz Type of protection IP20 Dimensions L x W x H 150 x 90 x 40 mm È Standards, page 2 Wiring diagrams and installation examples, page 2 PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HI HS 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per pc. For luminaires with 1 lamp PCI 45 outdoor DIM B011 86459332 16 pc(s). 480 pc(s). 0.700 kg PCI 50 outdoor DIM B011 86459336 16 pc(s). 480 pc(s). 0.700 kg PCS 50 outdoor DIM B011 86459335 16 pc(s). 480 pc(s). 0.700 kg PCI 60 outdoor DIM B011 86459159 16 pc(s). 480 pc(s). 0.697 kg PCI 70 outdoor DIM B011 86459337 16 pc(s). 480 pc(s). 0.700 kg PCS 70 outdoor DIM B011 86458595 16 pc(s). 480 pc(s). 0.720 kg PCI 90 outdoor DIM B011 86459160 16 pc(s). 480 pc(s). 0.749 kg PCIS 100 outdoor DIM B011 86458596 16 pc(s). 480 pc(s). 0.760 kg PCI 140 outdoor DIM B011 86459161 16 pc(s). 480 pc(s). 0.727 kg PCIS 150 outdoor DIM B011 86458597 16 pc(s). 480 pc(s). 0.747 kg Specific technical data Lamp wattage Lamp type Type Article number Lamp power Circuit power 1 EEI Efficiency Current at 50 Hz 230 V Max. cable length to lamp tc point max. Ambient temperature ta tc/ta for ≥ 60,000 h For luminaires with 1 lamp 1 x 45 W HI PCI 45 outdoor DIM B011 86459332 45 W 52 W A2 > 88 % 0.23 A 5 m / 400 pF 70 °C -25 ... +60 °C 70/60 °C 1 x 50 W HI PCI 50 outdoor DIM B011 86459336 50 W 57 W A2 > 88 % 0.25 A 5 m / 400 pF 70 °C -25 ... +60 °C 70/60 °C 1 x 50 W HS PCS 50 outdoor DIM B011 86459335 50 W 57 W A2 > 88 % 0.25 A 5 m / 400 pF 70 °C -25 ... +60 °C 70/60 °C 1 x 60 W HI PCI 60 outdoor DIM B011 86459159 60 W 68 W A2 > 88 % 0.30 A 5 m / 400 pF 70 °C -25 ... +60 °C 70/60 °C 1 x 70 W HI PCI 70 outdoor DIM B011 86459337 70 W 81 W A2 > 88 % 0.35 A 5 m / 400 pF 70 °C -25 ... +55 °C 70/55 °C 1 x 70 W HS PCS 70 outdoor DIM B011 86458595 73 W 81 W A2 > 88 % 0.35 A 5 m / 400 pF 70 °C -25 ... +55 °C 70/55 °C 1 x 90 W HI PCI 90 outdoor DIM B011 86459160 90 W 99 W A2 > 91 % 0.45 A 5 m / 400 pF 70 °C -25 ... +55 °C 70/55 °C 1 x 100 W HI & HS PCIS 100 outdoor DIM B011 86458596 100 W 109 W A2 > 91 % 0.50 A 5 m / 400 pF 70 °C -25 ... +55 °C 70/55 °C 1 x 140 W HI PCI 140 outdoor DIM B011 86459161 140 W 155 W A2 > 91 % 0.65 A 5 m / 400 pF 75 °C -25 ... +55 °C 75/55 °C 1 x 150 W HI & HS PCIS 150 outdoor DIM B011 86458597 147 W 161 W A2 > 91 % 0.70 A 5 m / 400 pF 75 °C -25 ... +55 °C 75/55 °C 1 At ta = 25 °C. PHASED OUT

Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

www.tridonic.com 1Subject to change without notice.

Data sheet 10/14-832-11

HID control gearElectronic

Product description

•Pulsepacketsforincreasedignitionenergy

(pulseCONTROLtechnology)

•Flicker-freelight

•Colourstabilitythankstoconstantpower

•Noacousticresonance

•Safetyshutdownifalampisfaultyormissing

•Greatlyreducedreignitiontime

•HardlyanyEMCinterferenceintheignitionphase

•Screwterminals:≤1.5mm²forstrandedwire,

≤2.5mm²forsolidwire

•Dimmingviadigitalinterface

•Noise-freeprecisecontrolviaDALI,DSIorstepDIM

•FaultreportinginDALImode

•Unitfullyencasedtoprotectagainstdust,moistureandvibration

•Enhancedprotectionagainstmainstransients

•Enhancedinsulation

•Casing:polycarbonate,black

Technical dataMainsvoltagerange 220–240V

ACvoltagerange 198–254V

Mainsfrequency 50/60Hz

λat50Hz230V 0.97

Max.ignitionvoltagePCI,PCIS 5kVp

Max.ignitionvoltagePCS 2.5kVp

Operatingfrequency 145Hz

Typeofprotection IP20

DimensionsLxWxH 150x90x40mm

ÈStandards,page2

Wiring diagrams and installation examples,page2

PCIS, PCI, PCS outdoor DIM B011PCIoutdoor

HIHS

4,5

90

150130

40

Ordering data

Type Article number Packaging,carton

Packaging,pallet

Weightperpc.

For luminaires with 1 lamp

PCI 45 outdoor DIM B011 86459332 16pc(s). 480pc(s). 0.700kg

PCI 50 outdoor DIM B011 86459336 16pc(s). 480pc(s). 0.700kg

PCS 50 outdoor DIM B011 86459335 16pc(s). 480pc(s). 0.700kg

PCI 60 outdoor DIM B011 86459159 16pc(s). 480pc(s). 0.697kg

PCI 70 outdoor DIM B011 86459337 16pc(s). 480pc(s). 0.700kg

PCS 70 outdoor DIM B011 86458595 16pc(s). 480pc(s). 0.720kg

PCI 90 outdoor DIM B011 86459160 16pc(s). 480pc(s). 0.749kg

PCIS 100 outdoor DIM B011 86458596 16pc(s). 480pc(s). 0.760kg

PCI 140 outdoor DIM B011 86459161 16pc(s). 480pc(s). 0.727kg

PCIS 150 outdoor DIM B011 86458597 16pc(s). 480pc(s). 0.747kg

Specific technical dataLampwattage

Lamptype

Type Articlenumber Lamppower

Circuitpower1

EEI Efficiency Currentat50Hz230V

Max.cablelengthtolamp

tcpointmax.

Ambienttemperatureta

tc/tafor≥60,000h

For luminaires with 1 lamp1x45W HI PCI 45 outdoor DIM B011 86459332 45W 52W A2 >88% 0.23A 5m/400pF 70°C -25...+60°C 70/60°C

1x50W HI PCI 50 outdoor DIM B011 86459336 50W 57W A2 >88% 0.25A 5m/400pF 70°C -25...+60°C 70/60°C

1x50W HS PCS 50 outdoor DIM B011 86459335 50W 57W A2 >88% 0.25A 5m/400pF 70°C -25...+60°C 70/60°C

1x60W HI PCI 60 outdoor DIM B011 86459159 60W 68W A2 >88% 0.30A 5m/400pF 70°C -25...+60°C 70/60°C

1x70W HI PCI 70 outdoor DIM B011 86459337 70W 81W A2 >88% 0.35A 5m/400pF 70°C -25...+55°C 70/55°C

1x70W HS PCS 70 outdoor DIM B011 86458595 73W 81W A2 >88% 0.35A 5m/400pF 70°C -25...+55°C 70/55°C

1x90W HI PCI 90 outdoor DIM B011 86459160 90W 99W A2 >91% 0.45A 5m/400pF 70°C -25...+55°C 70/55°C

1x100W HI&HS PCIS 100 outdoor DIM B011 86458596 100W 109W A2 >91% 0.50A 5m/400pF 70°C -25...+55°C 70/55°C

1x140W HI PCI 140 outdoor DIM B011 86459161 140W 155W A2 >91% 0.65A 5m/400pF 75°C -25...+55°C 75/55°C

1x150W HI&HS PCIS 150 outdoor DIM B011 86458597 147W 161W A2 >91% 0.70A 5m/400pF 75°C -25...+55°C 75/55°C1 Atta=25°C.

PHASED OUT

Page 2: Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

www.tridonic.com 2Subject to change without notice.

Data sheet 10/14-832-11

HID control gearElectronic

Installation instructions

Wiring type and cross sectionStrandedwirewithendferrulewithacrosssectionof1.5mm²orsolidwireupto2.5mm²maybeusedforwiring.Strip6mmofinsulationfromthecablestoensureperfectoperationofthescrewterminals.

6mm

wirepreparation:0.5–2.5mm²

Circuit diagram PCIS class 1 application

StandardsEN55015(radiointerference)EN61000-3-2(mainsharmonics)EN61347-2-12EN61547(interferenceimmunity)IEC62368-203(DALIstandard)CEmarkENECmark

Radio interference•Donotcrossmainsandlampcables.•Donotlaymainscablestogetherwithlampcables(ideallytheyshouldbe5–10cmapart).

•Donotleadmainscablestoocloselyalongtheelectronicballast.

•Twistlampcables.• Increasethedistancebetweenlampcablesandearthedmetalsurfaces.

•Keepthemainscableintheluminaireshort.•Parallelruns(x)ofmainsandlampcablesmustbekeptasshortaspossible.

Note on wiringThelengthofthelampwiresislimitedbythevalueofcablecapacitance.Themaximumof400pFwouldenableconnectionofapproximately5metresoflampwire.

Toavoidthedamageofthecontrolgear,thewiringmustbeprotectedagainstshortcircuitstoearth(sharpedgedmetalparts,metalcableclips,louver,etc.).

Inclass1luminairesitisnecessarytoearththeballastandtheluminaireviatheearthterminal.

Protectionclass2luminairesdonotneedanearthconnection.Insulationmustbeprovidedbytheluminairedesign.

Important adviseWhenalampischanged(attheendofitslife),ifalampismissing,orafterovertemperatureshutdownthemainsvoltageoftheECGmustbedisconnected.AlternativelyanOFFONsequencecanbesent.

Warning – starting voltage up to max. 5 kV!Notsuitableforusewithlampswithintegralignitors.AlistofreleasedlampsforthesaveoperationwithPCIScanbefoundonwww.tridonic.com→Techn.Data→Lampmatrix→LampMatrixforHID

Safety switch off

End of life of the lampsAttheendoftheirusefullife,lampsoftencycleon/off.ThePCISballastrecognisesthisconditionandswitchesoffthelamp,afterthreecompleteon/offcyclesandwhilstthesupplyhasbeenunswitched.Completelampswitch-offenableseasyidentificationofadefectivelampintheapplication.Afterachangeofthefaultylampandaninterruptionofthemainssupply(mainsreset)orsendaON-OFFsequencetheballastwillstrikethelamp.Whenthereisnolampincircuitoradefectivelampisconnectedtotheballast,theballastwillswitchoffafterapr.25minutes.

Overtemperature shutdownTheballastsareequippedwithathermalshutdowntoprotectagainstdestruction.AftershutdowntheycanberestoredwithanOFF-ONsequenceviaDALI/DSIorwithamainsreset.

Overload strength320VAC/1h

DADA

PCI

max. 5 kV

LN

Pe

DALI/DSIDALI/DSI

1

2

3

4

5

6

7

9

Circuit diagram PCIS class 2 application

DALI/DSIDALI/DSI

DADA

LN

Pe

PCI

max. 5 kV

1

2

3

4

5

6

7

9

Mounting recommendationToensureoptimumheatremovaltheECGshouldbemountedonametalplate(luminairebody).NoinsulatorsbetweentheECGandthethecoolingsurface(air,adhesivetape,etc.).Finally,thetemperaturemeasurementremainsimportant.

luminaire

PCI

luminaire

gap

PCI

Ifseveralballastsareinstalledinmasts,boxes,etc.,measuresmustbetakentoavoidoverheatingofindividualcomponents.

accordingtoEN61000-4-5.Protectedagainstasingle10kVpulse.

Harmonic distortion in the mains supply

Type THDPCI 45 outdoor DIM B011 <10%PCI 50 outdoor DIM B011 <10%PCS 50 outdoor DIM B011 <10%PCI 60 outdoor DIM B011 <10%PCI 70 outdoor DIM B011 <10%PCS 70 outdoor DIM B011 <10%PCI 90 outdoor DIM B011 <10%PCIS 100 outdoor DIM B011 <10%PCI 140 outdoor DIM B011 <10%PCIS 150 outdoor DIM B011 <10%

Ballast lumen factor EN 60929 8.1

TypeAC/DC-BLF

atU=198–254V,25°CPCI 45 outdoor DIM B011 1.00PCI 50 outdoor DIM B011 1.00PCS 50 outdoor DIM B011 1.00PCI 60 outdoor DIM B011 1.00PCI 70 outdoor DIM B011 1.00PCS 70 outdoor DIM B011 1.00PCI 90 outdoor DIM B011 1.00PCIS 100 outdoor DIM B011 1.00PCI 140 outdoor DIM B011 1.00PCIS 150 outdoor DIM B011 1.00

Transient protectionType L/N-PE L-N

PCI 45 outdoor DIM B011 4kV 6kVPCI 50 outdoor DIM B011 4kV 6kVPCS 50 outdoor DIM B011 4kV 6kVPCI 60 outdoor DIM B011 4kV 6kVPCI 70 outdoor DIM B011 4kV 6kVPCS 70 outdoor DIM B011 4kV 6kVPCI 90 outdoor DIM B011 4kV 6kVPCIS 100 outdoor DIM B011 4kV 6kVPCI 140 outdoor DIM B011 4kV 6kVPCIS 150 outdoor DIM B011 4kV 6kVPHASED OUT

Page 3: Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

www.tridonic.com 3Subject to change without notice.

Data sheet 10/14-832-11

HID control gearElectronic

Dimming of HID lampsUsingPCISballastsHIDlampscanbedimmeddownto40%lightoutput.Inprincipleallsodiumlampscanbedimmeddownto40%.Duetothelampcharacteristicsofmetalhalidelampsonlyselectedlampsarereleasedfordimming.TheminimumdimlevelofPCI45/60/90/140outdoorDIMB011issetaccordingtothelampspecification.Iflampsareoperatedbelowtheirspecifiedmini-mumdimlevel,performanceandlife-timecanbedeclined.AfterstartingupthePCISstepDIMtheconnectedlampneedstobeburnedinforthefirst19mininoperation.Apowerreductionwithinthese19minisnotpossible.Whenleavingtheinterfaceopentheballastsstayon100%lightoutput.Atadimminglevelof40%thelightoutputcanvaryduetothelampcharacteristicsbetween20and45%.AlistofreleasedlampsforthesaveoperationwithPCIScanbefoundonwww.tridonic.com→Techn.Data→Lampmatrix→LampMatrixforHID

Dimming via DALI/DSIViaDALI/DSIthelampcanbedimmedbetweenthepreadjustedminimumandDALI254/DSI255(100%).UsingDALI/DSIlevelsbetween1andthepreadjustedminimumdimmlevelthelightoutputistheminimumdimmlevel.

50%

100%

1 222 254

Lamp Power

...

Light Output

45%

20%

DALI/DSI

Dimming via stepDIMViastepDIMitispossibletoselect2dimlevelsviamains.ThetwolevelsareprogrammableusingDALI/DSI.Whenconnectingmains(e.g.viaZRMU6MA003*)totheinterfacetheballastregulatesto100%.Afterswitchingofftheinterfacetheballastregulatesto40%within90s.

DADA

PCISoutdoorDIM B011

max. 5 kV

LN

Pe

e.g. ZRM U6M A003*

100 %1

2

3

4

5

6

8

7

9

DADA

PCISoutdoorDIM B011

max. 5 kV

LN

Pe

e.g. ZRM U6M A003*

40 %1

2

3

4

5

6

8

7

9

PCIS outdoor DIM B011 100 % operating SK1 Lamp

PCIS outdoor DIM B011 40 % operating SK1 Lamp

Control input (DA)DigitalDALI/DSIsignalcanbewiredontheterminalsDA.

Digital signal DALI/DSIThecontrolinputisnon-polarandprotectedagainstaccidentalconnectionwithamainsvoltageupto264V.ThecontrolsignalisnotSELV.Controlcableshouldbeinstalledinaccordancewiththerequire-mentsoflowvoltageinstallations.Differentfunctionsdependingoneachmodule.

Standards (DALI)HIDEVG→devicetype2DALI0=0%lightDALI1...222=40%light

Programmable parameters•Groups1–16•Scenes1–16(values0%/40%...100%/MASK)•PowerOnLevel(values0%/40%...100%)•SystemFailureLevel(values0%/40%...100%)

QueriesviaDALIstandard:•Lampwattage(valueyes/no)•Lamperror(valueyes/no)

viaTridonicmasterCONFIGURATOR:•Lamptype•Devicetype•Articlenumber•Productiondate•Serialnumber•Softwareversion•Commissioning

OEM Memory BankThecustomercanstoreadditionalluminaireinforma-tionintheECG(MemoryBank1),suchasluminairetypeandarticlenumber.DataiswrittentoMemoryBank1inaccordancewithDALIstandardIEC62368.

Control via DALI/DSI

Loading of automatic circuit breakersAutomaticcircuitbreakertype C10 C13 C16 C20 B10 B13 B16 B20

InstallationØ 1.5mm2 1.5mm2 1.5mm2 2.5mm2 1.5mm2 1.5mm2 1.5mm2 2.5mm2

PCI 45 outdoor DIM B011 14 25 36 42 8 14 25 30

PCI 50 outdoor DIM B011 14 25 36 42 8 14 25 30

PCS 50 outdoor DIM B011 14 25 36 42 8 14 25 30

PCI 60 outdoor DIM B011 14 25 36 42 8 14 25 30

PCI 70 outdoor DIM B011 14 25 36 42 8 14 25 30

PCS 70 outdoor DIM B011 14 25 36 42 8 14 25 30

PCI 90 outdoor DIM B011 10 18 26 30 6 10 13 13

PCIS 100 outdoor DIM B011 10 18 26 30 6 10 13 13

PCI 140 outdoor DIM B011 7 14 20 20 4 6 7 7

PCIS 150 outdoor DIM B011 7 14 20 20 4 6 7 7

Factory settings minimum dimming value

TypeDALI DALI%

PCI 45 outdoor DIM B011 247 82%PCI 50 outdoor DIM B011 235 60%PCS 50 outdoor DIM B011 222 40%PCI 60 outdoor DIM B011 239 66%PCI 70 outdoor DIM B011 235 60%PCS 70 outdoor DIM B011 222 40%PCI 90 outdoor DIM B011 226 47%PCIS 100 outdoor DIM B011 222 40%PCI 140 outdoor DIM B011 224 44%PCIS 150 outdoor DIM B011 222 40%

PHASED OUT

Page 4: Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

www.tridonic.com 4Subject to change without notice.

Data sheet 10/14-832-11

HID control gearElectronic

1. Cooling phaseHIDEVG→DeviceType2Thelightingmusthavebeenswitchedoffbeforestart-upforatleast10min.(visualization/groupingisnotpossiblewithhotlamps)

2. Initialisation and addressing phase•LaunchDALImasterCONFIGURATOR•Clickon“Adressingwizzard”andfollowtheon-screeninstructions.

PCISoutdoorDIMdevicesremaindarkduringtheentireaddressingphase.Incontrast,DALIdevicesforfluorescentlamps,LEDsandincandescentlampsfadedowntotheirminimumvalueandgoto100%duringtheaddressingphase.Attheendoftheaddressingphasetheyfadebacktotheirminimumvalue.

3. Visualisation in the grouping phase•Activatethe“Enableopticalselectionfeedback”bytickingthecheckbox.

• IfaPCISoutdoorDIMdevice(DeviceType2,specialsymbol)isselectedinmasterCONFIGURATORtheappropriatedeviceswitcheson.ItremainsonuntiladifferentDALIdeviceisselectedinthesystem.→PCISoutdoorDIMthenswitchesoffafteramaximumdelayof10seconds.

4. Operation•PCISoutdoorDIMdevicescanbeswitchedpower-lesswithabroadcastsignal(DALIorDSI,withoutaddressingofthedevices)

•PCISoutdoorDIMdevicescanbeaddressedandoperatedindividuallyoringroupswithaDALIsignal.ForexampleswithTridoniccontrolspleaseseematrixabove.

Step-by-step commissioning withmasterCONFIGURATOR ≥ V2.0.0

0%

100%

0%

100%

10 min.

lamp first device lamp second device

light

start

first PCI outdoor DIM second PCI outdoor DIM

2.Initialization/

addressing phase

1.Cooling phase

3.Grouping phase

4.Operation

endfirst device selected(Recall Max.)

second device selected(Recall Max.)

10 Min.

Lampe 1. Gerät Lampe 2. Gerät

Licht

Start

1. Gerät PCI outdoor DIM 2. Gerät PCI outdoor DIM

2.Initialisierungs-/

Adressierungsphase

1.Kühlphase

3.Gruppierungsphase

4.Betrieb

EndeAuswahl 1. Gerät(Recall Max.)

Auswahl 2. Gerät(Recall Max.)

Overview – commissioning cycle with masterCONFIGURATOR ≥ V2.0.0

Commissioning comparison table

DALI HID ballast PCISoutdoorDIM

Standard DALI ballast e.g.PCAExcelone4all

Beforecommissioningtheinstallation

Devicesmusthavebeenswitchedoffforatleast10minutes!

Initialisationandaddressingphase

Devicesremainswitchedoff

• Devicesfadetominimumvalue• Onsuccessfuladdressingthedevicesfadeupto100%

• Attheendoftheaddressingphasethedevicesfadedowntotheminimumvalue

Visualisationinthegroupingphase

• Selecteddevicestartsthelampat100%• Ifadifferentdeviceisselectedthepreviouslyselecteddeviceswitchesoffwithamaximumdelayof10s

Visualisation/grouping is not possible with hot HID lamps!

• Selecteddevicefadesfromminimumvalueto100%

• Ifadifferentdeviceisselectedthepreviouslyselecteddevicefadestotheminimumvalue

Operation Devicescanbecontrolled/operatedwithotherDALI/DSIcontrolproducts

Devicescanbecontrolled/operatedwithotherDALI/DSIcontrolproducts

Commissioning of PCIS outdoor DIM ballasts

BecauseofthespecialcharacteristicsofHIDlightsources,PCISoutdoorDIMballasts(DeviceType2)cannotbeaddressedinthesamewayasconventionalDALIballastsforfluorescentorhalogenlampsforexample.ForvisualisationduringthegroupingphasetheHIDlampsmustremainswitchedoffbeforeandduringtheaddressingphaseastheycanonlybeproperlyignitedinthecoldstate.Dimmedoperationoftheselampsisnotrecommended,whichalsocallsfordifferenthandlingduringcommissioning.

TridonicrecommendsmasterCONFIGURATOR≥V2.0.0softwareforcommissioningPCISoutdoorDIMballasts(downloadfromwww.tridonic.com→Services→Software).

IMPORTANT:OtherDALIcontrollerscanonlybeusedforcommissioningiftheyhandleDALIDeviceType2unitsappropriately(seeRequirementsofcontrolproducts).

INITIALIZE.........RECALL MIN LEVEL.........TERMINATE

Requirements of control products

Initialization/addressingphase:

(Thiscommandmustbesentfirst)

WhentheINITIALIZEcommandis

sent,PCISoutdoorDIMdevices

changethe

RECALLMINvalueto0%Êde-

vicesswitchoff/remainswitchedoff

(Lastcommandintheinitialization

phase)

WhentheTERMINATEcommand

issent,PCISoutdoorDIMchanges

theRECALLMINvaluebackto40%

(100%light)

Realisation with Tridonic controls

Commissioning OperationDALIGC Gx-touchPANEL G Gx-touchBOX G GDALITOUCHPANEL GSoftwaremasterCONFIGURATOR G G

Thehighignitionvoltageofhighpressurelampscanleadtointerferences.Duringtheignitiontimethecommunicationcanbedisturbed.Thereforetheballastmightnotreactduringtheignitionphase.Thishastobeconsideredespeciallywhenusinggateways.

PHASED OUT

Page 5: Electronic - Tridonic€¦ · PCIS, PCI, PCS outdoor DIM B011 PCI outdoor HS HI 4,5 90 150 130 40 Ordering data Type Article number Packaging, carton Packaging, pallet Weight per

www.tridonic.com 5Subject to change without notice.

Data sheet 10/14-832-11

HID control gearElectronic

Temperature range

Thetatemperaturevalueisthebasisforspecifyingtheratedlife.Therelationshipbetweenthetctemperatureandthetatemperaturedependsonthedesignoftheluminaire.PCISoutdoorB011isdesignedforanaveragelifeof60,000hoursunderratedconditions,withafailureprobabilityoflessthan10%.Thiscorrespondstoanaveragefailurerateof0.2%per1,000hoursofoperation.Thespecifiedtctemperatureisthemaximumpermittedvalue(ratedtemperatureaccordingtoEN61347-1).Abovethissafety-relatedvaluethethermalcutoutprotectsthedeviceagainstdamage.Theexpectedlife-timevaluesareshowninthefollowingtable.Thetcvaluesaretherelevantvalueshere.

Expected life-time

Type Lamptype Lamppower ta 40°C 50°C 55°C 60°C

PCI45outdoorDIMB011 HI 1x45Wtc 50°C 60°C 65°C 70°CLife-time >100,000h >100,000h 80,000h 60,000h

PCI50outdoorDIMB011 HI 1x50Wtc 50°C 60°C 65°C 70°CLife-time >100,000h >100,000h 80,000h 60,000h

PCS50outdoorDIMB011 HS 1x50Wtc 50°C 60°C 65°C 70°CLife-time >100,000h >100,000h 80,000h 60,000h

PCI60outdoorDIMB011 HI 1x60Wtc 50°C 60°C 65°C 70°CLife-time >100,000h >100,000h 80,000h 60,000h

PCI70outdoorDIMB011 HI 1x70Wtc 55°C 65°C 70°C xLife-time >100,000h 80,000h 60,000h x

PCS70outdoorDIMB011 HS 1x70Wtc 55°C 65°C 70°C xLife-time >100,000h 80,000h 60,000h x

PCI90outdoorDIMB011 HI 1x90Wtc 55°C 65°C 70°C xLife-time >100,000h 80,000h 60,000h x

PCIS100outdoorDIMB011 HI/HS 1x100Wtc 55°C 65°C 70°C xLife-time >100,000h 80,000h 60,000h x

PCI140outdoorDIMB011 HI 1x140Wtc 60°C 70°C 75°C xLife-time >100,000h 80,000h 60,000 x

PCIS150outdoorDIMB011 HI/HS 1x150Wtc 60°C 70°C 75°C xLife-time >100,000h 80,000h 60,000h x

Additional information

Additionaltechnicalinformationatwww.tridonic.com→TechnicalData

Guaranteeconditionsatwww.tridonic.com→Services

Nowarrantyifdevicewasopened.

Storage conditions

Humidity: 5%uptomax.85%, notcondensed (max.56days/yearat85%)

Storagetemperature:-40°Cuptomax.+80°C

Thedeviceshavetobewithinthespecifiedtemperaturerange(ta)beforetheycanbeoperated.

Isolation and electric strength testing of luminaires

Electronicdevicescanbedamagedbyhighvoltage.Thishastobeconsidereddur-ingtheroutinetestingoftheluminairesinproduction.

AccordingtoIEC60598-1AnnexQ(informativeonly!)orENEC303-AnnexA,eachluminaireshouldbesubmittedtoanisolationtestwith500VDCfor1second.Thistestvoltageshouldbeconnectedbetweentheinterconnectedphaseandneutralterminalsandtheearthterminal.Theisolationresistancemustbeatleast2MΩ.

Asanalternative,IEC60598-1AnnexQdescribesatestoftheelectricalstrengthwith1500VAC(or1.414x1500VDC).Toavoiddamagetotheelectronicdevicesthistestmustnotbeconducted.

PHASED OUT