8
Electrical Power Solutions Emergency Lighting Inverters for commercial, industrial, educational, and medical facilities. Uninterruptible Power Systems for I.T., vehicle / cargo scanning, telemetry, industrial controls, and testing applications. Power Conditioning Voltage Regulators & High Efficiency, K-Rated Power Conditioning Transformers for applications including industrial lasers and X-ray, VFD controls, laboratory instrumentation, and A / V recording equipment. Medical-Grade Power Conditioners & UPS for imaging and treatment modalities, healthcare I.T., MRI suites, and patient vicinity equipment. Industrial DC Power Supplies (Rectifiers) for electrocoating, anodizing, and other metal finishing applications. UL 60601-1 (Medical) UL 924 / C-UL Listed to CSA Standards (Emergency Lighting) UL / C-UL 1778 (Standard UPS) UL 1012 and 1561 (Power Conditioning Transformers)

Electrical Power Solutions

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electrical Power Solutions

Electrical Power Solutions

Emergency Lighting Invertersfor commercial, industrial, educational, and medical facilities.

Uninterruptible Power Systemsfor I.T., vehicle / cargo scanning, telemetry,

industrial controls, and testing applications.

Power Conditioning Voltage Regulators &High Efficiency, K-Rated

Power Conditioning Transformersfor applications including industrial lasers and X-ray, VFD controls,

laboratory instrumentation, and A / V recording equipment.

Medical-Grade Power Conditioners & UPS

for imaging and treatment modalities, healthcare I.T.,

MRI suites, and patient vicinity equipment.

Industrial DC Power Supplies (Rectifiers)for electrocoating, anodizing, and other

metal finishing applications.

UL 60601-1 (Medical)UL 924 / C-UL Listed to CSA Standards (Emergency Lighting)

UL / C-UL 1778 (Standard UPS)UL 1012 and 1561 (Power Conditioning Transformers)

Page 2: Electrical Power Solutions

2 © June 2021. Controlled Power Company. Intellistat TS™ and AnodeMON™ are trademarks of Controlled Power Company.

Controlled Power Company engineers and produces the industry’s highest quality electrical power solutions, capitalizing on over 45 years of design and manufacturing expertise. We have an enviable reputation for quality, which is reflected in the design, workman-ship, and performance of our products.

From Research and Development... through Engineering, Marketing, and Sales... through Manufacturing and Shipping... through Accounting and Customer Support, Controlled Power Company is never content with the status quo in either our products or our attention to our customers. We continue to be a leader in the broad range of markets we serve, by listening to our prospects and custom-ers, understanding their unique electrical challenges, and providing power quality solutions for mission critical and life safety applications.

EON Model EL3 (10 kW to 55 kW Three Phase)

• Computer-based, self-testing / self-diagnostic emergency lighting system with data-logging and reporting (NFPA 101, 7.9.3.1.3).

• Physically smaller than comparable three-phase emergency lighting inverter products, without compromising performance or serviceability.

• 90 minutes runtime requires only (1) battery cabinet up to 33 kW, and only (2) battery cabinets for 40 kW – 55 kW.

• Only batteries with front-access terminals are used. • Optional seismic-rated models available.

Applications: Theaters / Concert Halls, Auditoriums, Casinos, Con-ference / Banquet Centers, Industrial Manufacturing, Warehouses

TrueLITE Model ELS(58.5 kW to 112.5 kW Three Phase)

• Offers (4) different field-selectable modes of operation based on input power conditions, lighting design, and the desire for high operating efficiency: On-Line, Standby-On (ECO Mode), Smart Active, and Standby-Off.

• Incorporates galvanic isolation and a robust design with a high overload capacity to deliver reliable emergency power for critical life safety loads.

• Full compliance with NFPA 101 as a computer-based, self-testing / self-diagnostic emergency lighting system with data-logging.

• Optional seismic-rated models available.

Applications: Correctional Facilities, School / University Buildings, Sports Facilities, Subway / Train Stations

• Wide graphic LCD display provides a close-up, detailed overview of the inverter status in real-time.

• Display features an opera-tional diagram, status and alarm messaging, main operating values, and easy pushbutton navigation.

• Easy viewing of all electrical parameters and alarm logs, as well as easy access to user-programmable settings.

• LED’s indicate main input power present, bypass input power present, output normal, on battery, on bypass, and alarm condition.

• Automatic battery testing; results logged with time and date stamp, and a pass or fail indication. Failed battery tests result in an audible and visual alarm.

Centralized Emergency Lighting Inverters — High Peak Overload Capability to accommodate inrush from LED fixtures / drivers!

Output Width Depth Height Rating (in.) (in.) (in.)

EON 33 kW 70 33 77

Competitor A 32 kW 130 32.5 71

Competitor B 33 kW 140 31 72 Note: Dimensions include 90 minutes of battery at full load.

Note: Illustration depicts 33 kW product without standard floor channels.

Download product brochure and specifications from any product webpage:

• Model EL3 • Model ELS

Page 3: Electrical Power Solutions

3

FastLITE Model FST(525 W to 2.2 kW Single Phase)

• Fast-transfer inverter providing a 2 millisecond or less transfer time to and from battery.

• Offered in wall- or floor-mount models.• Performs a weekly self-diagnostic

without needing to transfer to battery mode.

• Full compliance with NFPA 101 as a computer-based, self-testing / self-diagnostic emergency lighting system with data-logging.

• High efficiency design, with an operating efficiency of up to 98.8%!

Applications: Schools / Universities, Parking Structures / Garages, Office Buildings, Theaters, Worship Facilities

Advanced Digital Monitoring The Intellistat TSTM

• Color, TFT, high resolution touch-screen display for viewing system parameters, status, alarms, and programming of date / time values and system setpoints.

• Provides complete system diagnostics and testing, including all NFPA-compliant automatic battery testing and report logging.

• Performs egress lighting integrity test.

Available On:FastLITE Model FST: 525 W – 2.2 kWUltraLITE Model ELU: 1.5 kW – 14 kW sizes

Standard On:EON Model EL3: 10 kW – 55 kW three phase sizes

Network CommunicationsAll emergency lighting inverters are available with remote communication of test results and system status via Ethernet TCP/IP, BACnet, or MODBUS. Remote notification of alarms and status are also available via SNMP, e-mail, or the user’s building management system.

UltraLITE Model ELC (600 W to 2 kW Single Phase)

• Compact, front access design, featuring one of the smallest cabinet footprints in the industry.

• Uninterrupted, regulated, continuous sinewave output, compatible with all existing and future lighting loads.

• Timed Normally Off Bus “PLUS” option includes an adjustable soft start to accommodate the high inrush current of “normally off” emergency lights.

• High-speed automatic static bypass.• Manual bypass switch.• NEMA 2 drip-proof enclosure.

Applications: Commercial, Industrial, Schools, Hospitals, Office Buildings, Retail Stores, Multi-Unit Dwellings

UltraLITE Model ELU (1.5 kW to 14 kW Single Phase)

• Seamless transfer, online double-conversion system, compatible with all existing and future lighting loads.

• Automatic static bypass.• Secure, internal make-before-break

inverter bypass switch.• Basic or advanced Intellistat TS™

monitoring option.• 65k AIC rating available.

eLITE Models ELN (550 W to 1.5 kW Single Phase)ELE (5.3 kW to 18 kW Single Phase)

True uninterruptible power, designed for HID, incandescent, halogen, and quartz lighting applications, plus PFC electronic ballast loading up to 50% of the inverter’s rated output.

Applications: Commercial, Industrial, Schools, Hospitals, Arenas, Mass Transit, Airports, Restaurants, Worship Facilities

Centralized Emergency Lighting Inverters

Features And Benefits Common to Controlled Power Company Emergency Lighting Inverters• Meets NFPA 101 and 111 standards. NFPA compliant as “Life Safety Equipment”.• UL 924 Listed as “Emergency Lighting Equipment” with standard 90 minutes; optional battery runtimes available. • Uninterrupted, regulated power for normally on emergency lighting fixtures / exit lamps. (Excluding Model FST)• Emergency power supplied to “normally on and/or normally off” emergency circuits.• Front access design with small footprint – front access output distribution available on most models.

Download product brochure and specifications from any product webpage: • Model FST • Model ELC • Model ELU • Model ELN • Model ELE

Model ELU display shown

— High Peak Overload Capability to accommodate inrush from LED fixtures / drivers!

Optional seismic-rated models

Page 4: Electrical Power Solutions

4

LT Series (700 VA to 2.1 kVA)

• Tower (Model LT) or rack-mount (Model LTR) styles available.

• Line cord / receptacle or hardwired models.

• Model LTN (NEMA 2) UPS with extended battery runtimes; front access style enclosure.

• Model LTN-3R outdoor UPS with extended runtimes; NEMA 3R raintight enclosure design.

• Elastomeric insulation prevents condensation and internal moisture.

• Conformal coated circuit boards.• Runtimes from 30 minutes to 9.5 hours

at full load, model dependent.

Applications: LT, LTR, LTN — Industrial / Automated Process Controls, Point-of-Sale Computers, InstrumentationLTN-3R — Traffic Controls, Vehicle / Cargo Scanning, Solar Array Controls

MD Series (3.1 kVA to 7.5 kVA)

• Internal bypass option that “maintains system isolation and voltage transformation”.

• Multiple input / output voltage configurations.

• Custom-configured output distribution and receptacles.

Applications: LAN / WAN, Telecommunications, Industrial Controls

Model ES (4500 VA to 15500 VA)

• Online, double-conversion technology.

• Extended battery backup time, without the need for additional cabinetry.

• Choice of nominal input voltages, with conversion to the exact nominal output voltage needed, even in bypass.

• Color monitor with high-resolution touch-screen display.• Full network communications options.

Model ESV(1.5 kVA to 14 kVA)

• Online double-conversion technology.• Up to 4 hours of runtime in a front

access cabinet design, with zero side or rear clearance requirements.

• Color monitor with high-resolution touch-screen display.

Applications: ES, ESV — I.T. Server Rooms, Industrial Controls,

and Telemetry

HV Series (7.5 kVA to 25 kVA)

• Integral constant voltage transformer isolates and regulates output voltage.

• Internal bypass option that “maintains system isolation and voltage transformation”.

• Optional “System Power Analyzer” local monitor.

Applications: Windfarm Power Substations, SCADA / DCS, Extensive LAN / WAN Systems, Industrial Controls

Uninterruptible Power Supplies (UPS)

Features And Benefits Common to All Controlled Power Company LT, MD, and HV Series UPS’s• Steady, regulated output voltage to ± 3% of nominal, extends the life of protected equipment.• Built-in isolation eliminates electrical noise, and provides a “newly derived power source”.• Field-expandable power ratings, and optional extended battery runtimes.• Batteries are pre-assembled, installed, tested, and shipped within the UPS enclosure. (Excluding Model LTN-3R)• No-break, continuous power provides seamless transfer to back-up power, and prevents data loss.• Accelerated battery charger options.• Optional “NetMinder”™ UPS Management Suite software and hardware for UPS monitoring and unattended

computer / network shutdown.

Download product brochure and specifications from any product webpage: • Model LT • Model LTR • Model LTN • Model LTN-3R • MD Series • HV Series • Model ES • Model ESV

Model LTN-3R shown

Note: A proprietary technology is used to broaden the input operating range of the UPS as a function of load, down to -40% or -50% of the input voltage, model dependent. (Excludes HV Series.)

Page 5: Electrical Power Solutions

5

Series 700F Power Processor (10 kVA to 150 kVA Three Phase)

• Front access only! All installation, operation, maintenance, and testing can occur from the front of the unit — no side or rear access required.

• Identical voltage regulation and power conditioning performance as the Series 700A.

• Front access to all options including a regulator bypass, output distribution circuit breakers, and input / output digital meters.

• Advanced monitoring options include data-logging, programmable limit alarms, a waveform scope to view the real-time waveform for voltage and current, plus power quality monitoring with event logging.

• Optional communications include Ethernet TCP/IP and MODBUS TCP.

Applications: Commercial, Industrial, Power GenerationPlants, Refineries, Aerospace, Telecommunications, Pulp / Paper Mills, Industrial Lasers, UPS Bypass Circuits

Series 800 Power Purifier 800A Commercial Model (1 kVA to 15 kVA)800PI Industrial Model (500 VA to 25 kVA)

• Provides isolated, regulated, and noise-free electrical power to protect sensitive electronic equipment.

• Variable range regulation increases input voltage range under lighter loads, while tight output voltage is maintained.

• Provides power “ride-through”, even with the loss of input voltage for up to 1 cycle.

• 800PI models available in NEMA 1, 2, and 3R enclosures.

Applications: 800A — High-End Digital Photography, Security Systems,Medical Labs800PI — Industrial Networks, Automation Equipment, Machine Tools, PLC’s, Instrumentation, LED Billboards / Scoreboards

Series 700A Power Processor (5 kVA to 25 kVA Single Phase) (10 kVA to 1 mVA Three Phase)

• 7-tap, microprocessor- controlled.

• Precisely maintains correct voltage to ± 3% within one cycle, and maintains regulation during extended brownouts.

• Low output impedance transformer minimizes voltage distortion and sags commonly associated with high surge currents.

• Triple-shielded transformer provides a noise-free ground, attenuates voltage spikes and transients, and re-establishes the N-G bond.

• Internal bypass option that “maintains system isolation and voltage transformation.”

Applications: Food Processing, Pharmaceuticals, Commercial, Industrial, Audio / Visual, Wastewater Treatment, Robotics

Series 900/200 Power Commander (“Plus”) (15 kVA to 150 kVA Single Phase) (15 kVA to 450 kVA Three Phase)

• Precise electrical power for critical loads.• Automatic correction of voltage deviations to ± 1%

of nominal.• Adjustable output voltage.• Electronically and magnetically regulated — no moving parts,

virtually no preventive maintenance required.• High fault-clearing capability.• “Plus” models include computer-grade isolation transformers.

Applications: Test Laboratories, Industrial, Commercial, Distributed Control Systems (DCS), Power Generation Authorities, Regulated Bypass for Uninterruptible Power Systems, Broadcast Communications

Power Conditioning Voltage Regulators

800PI models shown

Download product brochure and specifications from any product webpage: • Series 700F • Series 700A• Series 800A • Series 800PI • Series 900/200 • Series 900/200 “Plus”

Page 6: Electrical Power Solutions

ULTRA-K Series 600K-he(5 kVA to 25 kVA Single Phase)(15 kVA to 500 kVA Three Phase)

• Meets and exceeds the high efficiency levels defined by the U.S. Department of Energy (DOE) 2016 Standard.

• K-factor ratings of K4, K7, K13, or K20 for full load compatibility with harmonic-rich non-linear loads.

• All copper windings and conductors with double-sized neutral.• Removes load-generated triplen harmonic currents from the input line.• Double- (126 dB) or triple-shielded (146 dB) for high common mode noise attenuation.• Optional output surge protection device (SPD) with high frequency noise filter.*• Standard, floor-mounted: NEMA 2 up to 225kVA; NEMA 1 at 300kVA and 500kVA.

Optional NEMA 3R outdoor enclosure available up to 225kVA.• IR scanning window(s) for safe, routine thermal scanning of transformer connections

under load, without exposing personnel to arc flash hazards.

* Contact factory and/or see product brochure for complete SPD details.

Applications: Audio / Video Recording Equipment, IT Systems / Computers, VFD Controls, Automated Scanning Electronics, Isolation for UPS, Laboratory Instrumentation, Electronic Measurement

High Efficiency K-Rated, Power Conditioning Transformers

Download product brochure and specifications from the product webpage: • ULTRA-K

6

SureImage Model Ultra-K/M (75 K(i) to 225 K(i) Three Phase)

• Meets and exceeds DOE 2016 minimum efficiency standards.

• SPD with high frequency filter.• 146 dB common mode

noise attenuation.• K13 rated for harmonic-rich

non-linear loads.

Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology

SureImage Model 700F/M (60 K(i) to 260 K(i) Three Phase)

• Output line voltage regulation ± 2%, typical.

• Up to 97% efficiency.• Front access enclosure.• Optional input and output metering

with real-time monitoring and waveform viewing.

• Optional output circuit breakers.

Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology, Linear Accelerator

MedPoweRx Model LT/M (700 VA to 2.1 kVA)

• Battery back-up for patient vicinity medical systems.

• Less than 300 micro-amps leakage current to ground.

• Optional specially-designed wheeled cart for portability.

Applications: Mammography, Ultrasound, Fluoroscopy, Dialysis, Hospital Room PC’s, Nurse Call Stations, Fetal Monitor Carts*

* Disclaimer: Product not intended for life support applications. Controlled Power Company does not accept any liability for this product being used with ventilators or any other life support systems.

Medical-Grade Power Conditioners and UPS

Features And Benefits Common to Both the SureImage Models Ultra-K/M and the 700F/M• “K(i) Rated” to meet the momentary power demand of

medical imaging and treatment equipment. • Significantly reduces / eliminates “artifacts” in the digital

image, which enhances workflow, increases patient throughput, and contributes to lower operating costs.

• Triple shielded isolation transformer provides excellent common and normal mode noise attenuation.

• Low output impedance delivers < 2% load regulation from typical steady state load to intermittent power demand.

Download product brochure and specifications from any product webpage: • Model Ultra-K/M • Model 700F/M • Model LT/M

Page 7: Electrical Power Solutions

7

Series 50 (Input AC Voltage: 208V – 600V 3 Phase; Output DC Voltage Range: 100V – 1,000V; Output DC Current Range: 500A – 5,000A)

• 6- and 12-pulse configurations.• High efficiency.• Air- or water-cooled flexibility.• Domestic and international

voltage capability.• Low ripple.• Tight voltage and current

regulation.• Diagnostic options for ease of

maintenance.• Plant PLC network integration.

AACD (Automatic Average Current Density)

• Adjusts DC voltage for proper e-coating film thickness.

• DC voltage adjustment based on load current to maximize savings on power and paint consumption.

• Compatible with batch or continuous conveyor processes.

• Compatible with various substrates.

Industrial DC Power Supplies (Rectifiers)

Series 70 (DC Output Ratings of 400V – 450V and 200A – 400A)

• Can be used in MAC or standalone rectifier configurations.

• 6- and 12-pulse configurations.• Front-access system; no back

or side access / clearance required.• Small footprint.• Extensive set of standard controls

and monitoring; including built-in anode monitoring.

• Flexible PLC distributed I/O configurations.

• Flexibility to use PLC’s from various manufacturers.

AnodeMON™(Anode Current Monitoring For Metal Finishing Processes)

• Ideal for cathodic and anodic metal finishing systems; e.g. e-coat and anodizing.

• PLC-based architecture gives the system operator real-time values for individual cell current during the finishing process.

• Values are viewable on and stored in an HMI (human- machine interface) for further analysis of process efficiency and cell life.

• Performs anode current monitoring in two (2) distinct configurations: “with” and “without” electrical distribution.

• Optional “AnodeHealth” software projects when an anode is near the end of its life, and informs the user when maintenance should be performed.

Download product brochure and specifications from either product webpage: • Series 50 • AACD • Series 70 • AnodeMon See more of our Industrial DC Power Supplies... visit our Rectifier product-family webpage!

Page 8: Electrical Power Solutions

MODEL SELECTION GUIDE

1955 Stephenson Hwy., Troy MI 48083www.controlledpwr.comemail: [email protected]: (800) 521-4792 Fax: (248) 528-0411

All information and data within this brochure is subject to change without notice.

EPS-010-0621

Represented by:

© Copyright June 2021. Controlled Power Company.

Warranty: Consult factory for specific product warranties, start-up services, and extended coverages.