EJECTION COOLING TOWER Saint-Petersburg. www.ooo-nt.ru. Thinking about the future, to create new. UNIQUENESS - EFFICIENCY. OWN PATENTED* PLANT, THAT SURPASSES IN ALL PARAMETERS THE WIDESPREAD FAN-ASSITED AND TOWERED-TYPE COOLING TOWERS POSSIBILITY TO WORK IN THE DISCRETE MODE IN ANY - PowerPoint PPT Presentation

Citation preview

Page 1: EJECTION COOLING TOWER Saint-Petersburg

EJECTION COOLING TOWER

Saint-Petersburg

www.ooo-nt.ru

Thinking about the future, to create new...

Page 2: EJECTION COOLING TOWER Saint-Petersburg

UNIQUENESS - EFFICIENCYOWN PATENTED* PLANT, THAT SURPASSES IN ALL PARAMETERS THE WIDESPREAD FAN-ASSITED AND TOWERED-TYPECOOLING TOWERS

POSSIBILITY TO WORK IN THE DISCRETE MODE IN ANY SEASON

ABILITY TO COOL FROM T = + 90 °C

HIGH OPERATIONAL CHARACTERISTICS

HIGH STABLE EFFICIENCY OF THE COOLING TOWER (15-30% HIGHER THANFAN-ASSISTED/AND TOWERED-TYPE ANALOGS)

LOW POWER CONSUMPTION OF COOLING TOWERS (UP TO 30% LOWERTHAN FAN-ASSISTED/AND TOWERED-TYPE ANALOGS)

ABSENCE OF FAN AND SPRINKLER

THERE IS NO NEED TO FEED FOR WATER TEMPERATURE DECREASE

2

*PATENT №72538, PATENT №2349851

Page 3: EJECTION COOLING TOWER Saint-Petersburg

SCHEMATIC DIAGRAM OF WATER COOLING SYSTEM PERFOMANCE

CP380/50 Hz

EQUIPMENT

AIR

HOT WATER

COOL WATER

3

Page 4: EJECTION COOLING TOWER Saint-Petersburg

EJECTION NOZZLES THE EFFECT OF EJECTION IS CREATED BY THE STREAM OF WATER DROPS PROCEEDING UNDER PRESSURE FROM

SPECIAL EJECTION NOZZLES

4

PROVISION OF THE EXTENDED COOLING SURFACE DON'T FREEZE AND DON'T SHATTER: nozzles are located at an angle, after work stoppage liquid is removed in natural way, restart doesn't require preparatory works

SYSTEM CLEANING WITHOUT STOPPING THE COOLING TOWER

WORK MAINTENANCE IN THE DISCRETE MODE

Page 5: EJECTION COOLING TOWER Saint-Petersburg

FILTRATION

5

Mud collector-filter Filter of thin cleaningCleaning from heavy mechanical impurity with a density >1000 kg/m ³ and size > 15 microns, and from easily emerging pollution

Preliminary or final filtration with the removal of the weighted and dust-like particles, filtration capacity from 200 to 1 micron

- The minimum hydraulic resistance (0,08-0,15 atm), not depending on the quantity of gathered pollution

- Working at water flow speed from 0,5 m/s to 2,5 m/s

-Removal of gathered pollution without stopping the filtration system

- Expendables and special service aren't required

- No grids and filtering materials

Page 6: EJECTION COOLING TOWER Saint-Petersburg

DROP CATCHERDROP CATCHER ALLOWS MINIMIZING WATER REMOVAL THAT RESULTS IN REDUCTION OF COSTS. FEED IS NECESSARY ONLY FOR EVAPORATION COMPENSATION (1 - 2% from the total amount of used water)

6

- RESISTANT TO RAPID TEMPERATURE CHANGE

- - IT IS NOT A SUBJECT OF BIOLOGICAL INCRUSTATION

- - EFFICIENCY OF DROP CATCHING – 99,99%

Page 7: EJECTION COOLING TOWER Saint-Petersburg

EGECTION COOLING TOWER CASE MATERIALS

7

- THE CASE IS MADE FROM THE REINFORCED POLYMERIC MATERIAL

- LIGHTWEIGHT- IT IS NEUTRAL TO CHEMICAL INFLUENCE AND CORROSION

- THE CASE FROM STEEL WITH THE CORROSION-RESISTANT COATING

- RESISTANT TO MECHANICAL DAMAGES- DOESN'T REQUIRE SPECIAL SKILLS AND MATERIALS TO

REPAIR

Heated water = 60°СChilled water = 25°С

Heated water = 38°СChilled water = 26°С

Page 8: EJECTION COOLING TOWER Saint-Petersburg

LAYOUT OF COLLING TOWERS

8

- CONSUMPTION OF WATER 100 – 300 M³/ h

- TEMPERATURE DIFFERENCE FROM 43 to 28 °C AT t = 40 °C and HUMIDITY 40%

- MONOBLOCK SYSTEM WITH MOUNTING ON THE ROOF OF THE PRODUCTION CASE

- CONSUMPTION OF WATER IS 2000 M³/ h

- SYSTEM AUTOMATIZATION REDUCES ENERGY CONSUMPTION AND SIMPLIFIES THE OPERATION

- CASES OF THE COOLING TOWER ARE LOCATED OVER THE PUMP STATION

Heated water = 32°СChilled water=24 °С

Page 9: EJECTION COOLING TOWER Saint-Petersburg

AUTOMATION SYSTEMTHE AUTOMATION SYSTEM ALLOWS SAVING FUNDS BY REDUCTION OF POWER CONSUMPTION AND COSTS FOR SERVICE STAFF

SYSTEM TAKES OVER SUCH MAJOR FUNCTIONS AS:MAINTENANCE OF THE CONSTANT PRESET TEMPERATURE OF CHILLED WATERMAINTENANCE OF THE CONSTANT PRESSURE IN THE PIPELINE, EVEN AT VARIABLE NUMBER OF CONSUMERSWATER LEVEL MAINTENANCE IN THE STORAGE TANK (SYSTEM FEED)

9

Page 10: EJECTION COOLING TOWER Saint-Petersburg

POWER CONSUMPTION

UNDER EQUAL CONDITIONS OF THE

ENVIRONMENT, EQUAL OPERATING TIME

AND EQUAL THERMAL LOADING – OUR

EJECTION COOLING TOWER HAS AN

OPPORTUNITY TO WORK CYCLICAL

AND TO CONSUME MUCH LESS ELECTRIC

POWER, UNLIKE FAN-ASSISTED COOLING

TOWER WITH THE CONSTANT OPERATING

MODE AND POWER CONSUMPTION.

BENEFIT FROM OPERATION OF THE EJECTION COOLING TOWER – IS OBVIOUS AND ALREADY TURNED BACK PROFIT FOR ALL OUR CLIENTS! ! !

10

Page 11: EJECTION COOLING TOWER Saint-Petersburg

ADVANTAGES OF THE EJECTION COOLING TOWER (comparison of the standard fan-assisted and ejection cooling tower)

11

FAN-ASSISTED EJECTION

The sprinkler collapses No sprinkler

Restriction on temperature of heated water +65 °C, restriction on temperature difference

Has no restrictions on temperature and differences (to t ≤ +90 °C)

Fan engines blow out, unbalance, high noise level Quiet in due to absence of fan

Requeres sufficient feed for water temperature decrease Feed for compensation of the evaporated water (1-2%)

Restart during the winter period requires the preparatory works

Works in a mode of frequent stops/starts in any time of the year

The efficiency of the cooling tower depends on fan efficiency

The efficiency is higher, than standard fan-assisted cooling towers and it is not changed during the whole service life

Power consumption is constant and depends on fan power Power consumption is lower up to 30%

Heat removal is adjusted by channeling effect and the frequency of fan operation

Heat removal is adjusted over the wide range, with decrease of power consumption

Page 12: EJECTION COOLING TOWER Saint-Petersburg

MODERNIZATION OF FAN-ASSISTED COOLING TOWERS

Modernization of cooling towers is performed due to dismantling of fan and sprinkler, with installation of ejection channels into air collector windows of the outdated fan-assisted cooling tower. Then the new water distribution system between collectors is mounted. IT ALLOWS: TO SAVE ON DEMOLITION OF OUTDATED COOLING TOWERS AND CONSTRUCTION OF THE NEW ONE TO REDUCE COSTS ON THE OPERATION AND MAINTENANCE OF NEW SYSTEM SUFFICIENTLY TO INCREASE THE POWER AND SYSTEM PERFORMANCE WITHOUT EXTENSION OF THE AREA

12

Page 13: EJECTION COOLING TOWER Saint-Petersburg

EFFICIENCY AND RELIABILITY

- Simplicity of construction - Operational reliability- Availability to survey and prevention- Absence of ice formation during the winter period- Doesn't require the highly skilled service personnel- Automatic temperature control of chilled water and pressure in system-Continuous operation as well as at frequent stops during winter period- Absence of vibration and low noise level, is reached by absence of moving elements in system- The dimensions of unit are significantly less than fan-assisted and towered cooling tower have, power is much higher- Possibility to install in any place, on factory territory or on the roof of production building

13

Page 14: EJECTION COOLING TOWER Saint-Petersburg

ECONOMIC BENEFIT

- Cleaning of nozzles without stopping the cooling tower- Absence of the basin (the underground tank) reduces the construction period and cost estimate- Sufficient decrease in costs for cooling tower service due to absence of the fan- Reduction of power consumption and costs for service personnel due to system automation- Reduction of pipeline length due to arrangement of cooling towers closely to production buildings - Feed for water temperature decrease isn't used- Capital costs are 1,5-2 times less (in comparison with standard fan-assisted cooling towers)- Operation costs are 40 - 50% lower- Quick payback of the cooling tower due to decrease of the costs for water consumption and water disposal The cooling tower is paid back in first - third month after operation

14

Page 15: EJECTION COOLING TOWER Saint-Petersburg

WE ARE TRUSTED

15

Page 16: EJECTION COOLING TOWER Saint-Petersburg

Relying on long-term cooperation, we are aiming to become the reliable partner for any client.

We guarantee the highest quality of the equipment, its stable and economically sound operation.

Yours faithfully, Director General