is validated and tested brand, you will be assured of all Electro-Contaminant Removal Systems (ECR) to be 100% Design and Manufactured completely in Singapore.
Cherith
ELECTRO-CONTAMINANT REMOVER
Page | 1
As our valued partners, we hope to share our technologies and experiences in the Waste Water &
Water Arena, and impart as much resources as we possibly could, for the extension of safe water
and guardian of our planet.
As Cherith
hereby look forward to a close collaboration, partnership and learning from you, whist at
the very same time, to receive in faith from above altogether, His blessings to us as stewards for an
important task bestowed in His time and opportunity.
Cherith Electro-Contaminant Removal System
Important Information:
• System compliant with exsiting Waste Water Treatment Facilities in Established Industries.
• Removes Fats, Oil & Grease, complex Organics, Metal as Oxides, Color, TSS & Colloidal solids, Reduces COD/BOD, breaks emulsions, destroy and removes Bacteria and Viruses
• 50% savings of total operation cost is expected as compared to Chemical treatment
• ECR systems are able to increase flow rates of exsisting Waste Water Treatment Facilities
• ECR treated water quality surpasses all Semi Con, Textile and Oil Industries pre-treatment
• Power consumptions are expected to average 0.5-0.8 kW/m3
• 0.02 kg/m3 for plate consumption which translates to 0.02 kg/m3 of sludge
• ½” >6 Bar Compressed Air of 2kg air minimum is required (scouring every 10mins for 3-4 sec)
• 1” Pipe in water point is required for ease of periodic maintenance
• Internal diffusers for solid lift installed
• System has to be placed on plinth and in well ventilated shelter
• Standard Sacrificial Steel Plates sizes are 600mm X 900mm
• First steel set to be outsourced locally (Minimises Transportation and Delivery dry weight)
• System is most effective with influent at pH 7.5, and should work fine between 6-9 pH
• Influent Screening required at 2mm mesh size
• 2” Sch 80 PVC – Acid supply for unit CIP and tankage
• 4” Sch 80 PVC flange for incoming influent connection
• 6” Sch 80 PVC flange for Gravity Discharge (To Flash Mixer/Clarifier/Sedimentation/Precipitation)
• Painted Carbon Steel Frame, Pre-plumbered and pre-wired onto Skid system
• IP 55 Full Eletrical Panel with cooling fins, Instrumentation and Control
• System comes as standard for hoisting by Fork Lift and Crane strap lifting
• 12 months Water Process Guarantee
• 12 Months Electrical and Mechanical Warranty
WATERPLUS PTE [email protected]
ELECTRO-CONTAMINANT REMOVER
Page | 2
ECR Machines comes in Standard as 5 Models Design
T10 Model T40 MODEL T20 Model
ELECTRO-CONTAMINANT REMOVER
Page | 3
ONLY ONE MOVING PART!!!
Bottom up Flow New Plate Used Plate Before After
Floc in broth ECR Systems functions via wastewater flowing through bottom up between the plates. This free flow allows access to the reactor chamber which is inspected once a day, and the sacrificial plates could be changed one at a time as they dissolve (75 – 90 days). Because there is NO PRESSURE within the atmospheric reactor chamber, the design is meant for simplicity in operations and maintenance, thus saving on operating consumables.
+90 % COLOR 40 to 60% COD +90% SOLIDS +75% SLUDGE +65% SAVINGS on Op. Cost REMOVAL REDUCTION REMOVAL REDUCTION Compared to Chemical Use
Mild Steel Plates Mild Steel Plates
ELECTRO-CONTAMINANT REMOVER
Page | 4
The ECR process is based on valid scientific principles involving responses of water contaminants to strong electric fields and
electrically induced oxidation & reduction reactions
CONSISTANT - RELIABLE & CHEMICAL FREE ---------------------------------------------------------------------------------------------------------------
MUNICIPAL or INDUSTRIAL INORGANIC & ORGANIC
Waste waters Contaminants
5 sets of T40B in operations at an Industrial Park Waste Water Treatment Plant
Electro Contaminant Removal Expected Annual Maintenance Cost
Sacrifices FERROUS at ONLY the rate of
0.04kg / 1m3 (1000 m3 = 40 KG/day) (Expected Steel consumption is = Sludge Amount as compared to chemical usage)
ECR costs average USD 0.07 – 0.11 ANNUAL Steel costs will not exceed USD6,000
ELECTRO-CONTAMINANT REMOVER
Page | 5
OIL & GAS Exploration
Parameter RAW ECR SCR
COD 610 141
BOD 375 50
Phenol 0.63 0.19
INDONESIA O&G 156 0.0
Produced Waters pH 7.5 8.7
Arsenic 180 0.0
Iron .52 0.0
Manganese .086 .009
COD 375 38
BOD 215 15
TSS 2,950 98
INDONESIA O&G 577 0.0
Drill Waters Turbidity 1,332 18
H2S .24 .02
Ammonia 38 4
Lead 0.73 .002
pH 8.0 8.2
Color 14,000 500
ELECTRO-CONTAMINANT REMOVER
Page | 6
TEXTILE
Industry Parameter RAW ECR Unit
TDS 2,930 3,000 APHA 2540
MALAYSIA TSS 57 4 APHA 2540
Dye & Finish COD 413 164 APHA 5220 BOD 148 78 APHA 5210
Mixed Wash Water Color >250 30 Hazen Unit
pH 9.72 10.8 APHA 4500
COD 871 98 APHA 5520
INDIA BOD 309 34 APHA 5210
Water Jet O&G 142 .02 APHA 5520
Yarn Weaving Color 150 10 APHA 2120
pH 5.84 8.59 APHA 4500
TDS 323 321 APHA 2540
SINGAPORE TSS 267 71 APHA 2540
Dye & Finish COD 842 355 APHA 5220
BOD 249 112 APHA 5210
Mixed Wash Water Color >250 60 Lovi - Meter
pH 10.3 10.9 APHA 4500
BANGLADESH TSS 60 8 Mg/L
Dye Factory #1 COD 310 125 Mg/L
DHAKA TSS 27 4 Mg/L
Dye Factory # 2 COD 190 28 Mg/L
TSS 83 18 Mg/L
Dye Factory # 3 COD 490 318 Mg/L
TSS 105 27 Mg/L Dye Factory # 4
COD 404 80 Mg/L
TSS 417 31 Mg/L
DENIM WASHING COD 808 190 Mg/L
ELECTRO-CONTAMINANT REMOVER
Page | 7
Primary Filter screens (Bar & Fine /Drum Screen)
Lift Station
Equalization Tank
Sludge Drying Systems
ASP Clarifier
ASP Feeding / Neutralization Section
ASP Oxidation Section
ASP Holding / Conditioning
Tanks
Sludge Holding Tank
Discharge to Receiving
Stream
Periodic
Excess
Sludge Bio
Mass
Return
Electro Contaminant
Removal (ECR)
ECR Clarifier
ELECTRO-CONTAMINANT REMOVER
Page | 8
REFERENCE LIST OF 2 MAJOR COUNTRIES/INDUSTRIES
BANGLADESH (TEXTILE)
FAKHRUDDIN TEXTILES MILLS LTD Supplied 1 unit T20 for Textile waste water treatment.
FAKHRUDDIN TEXTILES MILLS LTD Supplied 1 unit T20 for Textile waste water treatment.
RADIANCE / RADIAL INT'L LTD (UNIT-2) Supplied 1 unit T40 for Textile waste water treatment.
INTRAMEX TEXTILE LTD Supplied 1 unit T20 for Textile waste water treatment.
INTRAMEX TEXTILE LTD Supplied 1 unit T20 for Textile waste water treatment.
ZARJIS COMPOSITE KNIT INDUSTRIES (PVT) LTD Supplied 1 unit T40 for Textile waste water treatment.
ROBINTEX / COMPTEX BANGLADESH LTD Supplied 1 unit T40 for Textile waste water treatment.
D-WATER C.E.T.P. ECO SYSTEM (BD) LTD Supplied 6 units T60 for Textile waste water treatment
MULTIFABS LTD Supplied 1 unit T40 for Textile waste water treatment.
PARAGON KNIT COMPOSITE LTD Supplied 1 unit T20 for Textile waste water treatment.
FATULLAH FABRICS LTD Supplied 1 unit T20 for Textile waste water treatment.
WISDOM ATTIRES Supplied 1 unit T60 for Textile waste water treatment
AJI / POLO COMPOSITE KNIT INDUSTRY LTD Supplied 1 unit T60 for Textile waste water treatment
LE-NOUVEAUTEX (PVT) LTD Supplied 1 unit T40 for Textile waste water treatment.
UNILON TEXTILES LTD Supplied 1 unit T40 for Textile waste water treatment.
NATURAL WASHING (WASH & WEAR) LTD Supplied 1 unit T40 for Textile waste water treatment.
TANIA TEXTILES LTD Supplied 1 unit T20 for Textile waste water treatment.
GAZIPUR PAPERBOARD LTD Supplied 1 unit T40 for Pulp Paper industry waste water treatment.
MODELE DE CAPITAL INDUSTRIES LTD Supplied 1 unit T40 for Textile waste water treatment.
AHSAN COMPOSITE LTD Supplied 1 unit T40 for Textile waste water treatment.
SHOVON SILK KNITTING MILLS (PVT) LTD Supplied 1 unit T60 for knitting waste water treatment
CRYSTAL COMPOSITE LTD Supplied 1 unit T20 for Textile waste water treatment.
MASCO INDUSTRIES LTD Supplied 1 unit T40 for Textile waste water treatment.
ELECTRO-CONTAMINANT REMOVER
Page |
INDONESIA (OIL EXPLORATION) PT CHEVRON PACIFIC INDONESIA Supplied 3 units of T5 system for O & G Central Mud
Treatment facility
TAC PERTAMINA - PT INSANI MITRASANI GELAM Supplied 1 units of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - GOLDEN SPIKE INDONESIA LTD Supplied 1 unit of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - GOLDEN SPIKE INDONESIA LTD Supplied 1 unit of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - GOLDEN SPIKE INDONESIA LTD Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT CHEVRON PACIFIC INDONESIA Supplied 2 units of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - TALISMAN JAMBI MERANG Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT CHEVRON PACIFIC INDONESIA Supplied 2 units of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - GOLDEN SPIKE INDONESIA LTD Supplied 1 unit of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - TALISMAN JAMBI MERANG Supplied 1 unit of T5 system for O & G Drilling/Exploration
KSO PERTAMINA EP - PACIFIC OIL & GAS (PERLAK) LTD
Supplied 1 unit of T5 system for O & G Drilling/Exploration
KSO PERTAMINA EP - PACIFIC OIL & GAS (PERLAK) LTD
Supplied 1 unit of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - PETROCHINA EAST JAVA Supplied 2 units of T5 system for O & G Drilling/Exploration
PT PERTAMINA EP Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT PERTAMINA EP Supplied 2 units of T5 system for O & G Drilling/Exploration
JOB PERTAMINA - TALISMAN JAMBI MERANG Supplied 1 unit of T5 system for O & G Drilling/Exploration
TATELY N.V Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT PERTAMINA EP Supplied 1 unit of T5 system for O & G Drilling/Exploration
PACIFIC OIL & GAS (KISARAN) LTD Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT PERTAMINA EP Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT OGAN INTERIOR GAS Supplied 1 unit of T5 system for Coal Bed Methane Exploration
ELECTRO-CONTAMINANT REMOVER
Page | 10
TAC PERTAMINA EP - BWP MERUAP Supplied 1 unit of T5 system for O & G Drilling/Exploration
KALREZ PETROLEUM LTD Supplied 1 unit of T20 system for O & G Produced water Treatment
TAC PERTAMINA EP - BWP MERUAP Supplied 1 unit of T5 system for O & G Produced water Treatment
PT TRIDHARMA MEGAMITRA Supplied 1 unit of T40 system for O & G Drilling/Exploration
PT KARINA INDONESIA Supplied 1 unit of T5 system for Foods & Beverages
PT PENGELOLA LIMBAH KUTAI KARANEGARA (PT BUANA)
Supplied 1 unit of T5 system for O & G Drilling/Exploration
PT SWADAYA ABDI MANUNGGAL (KALREZ) Supplied 1 units of T20 system for O & G Produced water Treatment
PT SINAR ROMINDO INDAH Supplied 2 units of T5 system for O & G Drilling/Exploration
ECR SYSTEM CONFIGURATION
Model T5A T5B T10A T10B T20A Capacity
(m3/h) >5 >10 >15 >20 >30
Dimensions (mm)
2500 X 1371 X 2200
2500 X 1371 X 2200
2500 X 1371 X 2200
2500 X 1371 X 2200
3321 X 1772 X 2200
Dry/Wet Weight (kg)
1000 / 1700 1000 / 1700 1000 /1700 1000 / 1700 1500 / 4000
Head Loss 0.2 psi 0.00267m3/Hr
0.2 psi 0.00267m3/Hr
0.1 psi 0.004m3/Hr
0.1 psi 0.004m3/Hr
0.3 psi 0.005m3/Hr
CIP Tank and Acid Vol
1m3 1m3 1m3 1m3 1.5m3
All units comes as standard in 50Hz unless indicated for 60Hz
Supply Requirement : 380-440V AC (Clean power/Single Source)
Current Requirement : T5 & T10 – 100A, T20 – 200A, T40 – 400A, T60 – 500A
Model T20B T40A T40B T60A T60B Capacity
(m3/h) >40 >60 >80 >100 >120
Dimensions (cm)
3321 X 1772 X 2200
3321 X 3544 X 2200
3321 X 3544 X 2200
3321 X 6500 X 2200
3321 X 6500 X 2200
Dry Weight (kg)
1500 / 4000 2500 / 7000 2500 / 7000 4000 / 10000 4000 / 10000
Head Loss 0.3 psi 0.005m3/Hr
0.6 psi 0.005m3/Hr
0.6 psi 0.005m3/Hr
1 psi 0.005m3/Hr
1 psi 0.005m3/Hr
CIP Tank and Acid Vol
1.5m3 2.5m3 2.5m3 4m3 4m3