YM412i ELECTROCARDIOGRAPH Service Manual

Ecg Mediana Ym412i Service Manual

Embed Size (px)

DESCRIPTION

como se lee un electro

Citation preview

YM412i ELECTROCARDIOGRAPH Service Manual YM412i Service Manual EU representative TECNOMED 2000 S.L. Valencia, 25-28012 Madrid Spain Supplier MEDIANA Co.,Ltd. Wonju Medical Industry Park, 1650-1 Donghwa-ri, Munmak-eup, Wonju-si, Gangwon-do, Korea Tel: (82) 33 742 5400Fax: (82) 33 742 5618 Manufacturer MEDIGATE INC. 1720-26, Taejang-dong, Wonju-si, Gangwon-do, Korea Tel: (82) 33 747 3552Fax: (82) 33 747 3691 YM412i Service Manual Part Number-Revision Number: L05232-00 Printed in Korea Copyright 2006-2007 Mediana Co., Ltd. All rights reserved. Notice Thisdocumentcontainsproprietaryinformationthatisprotectedbycopyright.AllRights Reserved. Reproduction, adaptation or translation without prior written permission is prohibited, except as allowed under the copyright laws. Warranty Theinformationcontainedinthisdocumentissubjecttochangewithoutnotice.Mediana makesnowarrantyofanykindwithregardtothismaterial,including,butnotlimitedto,the implied warranties or merchantability and fitness for a particular purpose. Mediana shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Revision History Thedocumentpartnumberandrevisionnumberindicateitscurrentedition.Therevision numberchangeswhenaneweditionisprintedinaccordancewiththeversionofthe documentation. Minor corrections and upgrades which are incorporated at reprint do not cause the revision number to change. The document part number changes when extensive technical changes are incorporated. Contents Chapter 1. Information ................................................................................................. 9 1. General Information................................................................................................ 10 2. Safety Information.................................................................................................. 11 Chapter 2. Introduction .............................................................................................. 13 1. Device description.................................................................................................. 14 2. Standard Accessories ............................................................................................ 16 3. Contacting a Mediana Service Center .................................................................. 17 Chapter 3. Basic Care and Maintenance .................................................................. 19 1. Description.............................................................................................................. 20 2. Cleaning................................................................................................................... 20 3. Replacing Printer Paper ......................................................................................... 22 4. Battery maintenance and care............................................................................... 23 5. Firmware Upgrade .................................................................................................. 24 6. Cardiograph and Accessory Disposal .................................................................. 24 Chapter 4. Performance Verification and Safety Tests............................................ 25 1. Description.............................................................................................................. 26 2. Test Equipment ....................................................................................................... 26 3. Performance Verification Tests ............................................................................. 26 4. Safety Test............................................................................................................... 31 Chapter 5. Troubleshooting....................................................................................... 35 1. Description.............................................................................................................. 36 2. Service Technicians ............................................................................................... 36 3. Replacement Support............................................................................................. 36 4. Getting Replacement Parts.................................................................................... 36 5. Troubleshooting Topics ......................................................................................... 36 6. Battery and AC Power ............................................................................................ 38 7. Display..................................................................................................................... 40 8. Button...................................................................................................................... 41 9. Beep......................................................................................................................... 41 10. Printer .................................................................................................................... 42 11. Others .................................................................................................................... 43 Chapter 6. Disassembly Guide.................................................................................. 45 1. Description.............................................................................................................. 46 2. How to Use Disassembly Guide............................................................................ 47 3. Disassembly Flow Chart ........................................................................................ 47 4. Disassembling Cases............................................................................................. 50 5. Opening the device................................................................................................. 50 6. Lower Case Disassembly....................................................................................... 51 7. Upper Case Disassembly....................................................................................... 57 8. Specification of cables and connectors............................................................... 60 Chapter 7. Parts List................................................................................................... 65 1. Description.............................................................................................................. 66 Chapter 8. Packing ..................................................................................................... 69 1. Description.............................................................................................................. 70 2. Standard Carton Box Packing............................................................................... 70 3. Repacking................................................................................................................ 70 Chapter 9. Specifications........................................................................................... 71 Chapter 10. Functional Description .......................................................................... 75 1. Description.............................................................................................................. 76 2. System Overview.................................................................................................... 76 3. Hardware Functional View..................................................................................... 76 Figures Figure 2-1. Top Panel...15Figure 2-2. Rear Panel.15Figure 2-3. Right Panel15Figure 3-1. Cleaning the printer head..21Figure 3-2. Changing Printer Paper..22Figure 3-3. Firmware upgrading Screen.24Figure 4-1. Maintenance Menu Screen...............................................................................29Figure 6-1. Disassembly Flow Chart47Figure 6-2. Upper Case Disassembly..48Figure 6-3. Lower Case Disassembly.49Figure 6-4 Detach the Upper and Lower case..50Figure 6-5 Battery Disassembly51Figure 6-6 Thermal Printer Disassembly52Figure 6-7 Main Board Disassembly53Figure 6-8 Fuses replacement53Figure 6-9 Power Module Disassembly..54Figure 6-10 Replacing the CPU Module..55Figure 6-11. Keypad Disassembly57Figure 6-12. LCD and STN-SUB PCB Disassembly.58Figure 7-1. YM412i Parts.66Figure 10-1. Block Diagram of Entire instrument.76Figure 10-2. Power System Block Diagram77Figure 10-3. DC Power Supply Block Diagram.78Figure 10-4. Main CPU Module Block Diagram.79Figure 10-5. RTC Power Interface Block Diagram79Figure 10-6. Display Interface Block Diagram..80Figure 10-7. Keypad Interface Block Diagram..80Figure 10-8. Thermal Printer Interface Block Diagram81Figure 10-9. Communication Interface Block Diagram..81Figure 10-10. Analog Signal Acquisition Interface Block Diagram.82 Tables Table 2-1. List of Components.16Table 4-1 Top panel indicators for power source27Table 4-2 Battery Charging Status Indications27Table 4-3. Earth Leakage Current Values..31Table 4-4. Patient Leakage Current Values..32Table 4-5. Patient Leakage Current Values-Mains Voltage on Applied Part.32Table 4-6. Allowable Leakage Current33Table 5-1 Troubleshooting Topics...37Table 5-2 Battery and AC Power Troubleshooting.38Table 5-3 Display Troubleshooting.40Table 5-4 Button Troubleshooting..41Table 5-5 Beep Troubleshooting..41Table 5-6 Printer Troubleshooting..42Table 5-7 Others...43Table 6-1. Part Descriptions Lower Case Assembly...56Table 6-2. Part Descriptions Upper Case Assembly...59Table 6-3. Main PCB to Keypad PCB Cable..60Table 6-4. Main PCB to STN-SUB PCB Data Cable.61Table 6-5. STN SUB PCB to LCD Back Light Cable61Table 6-6. Main PCB to Printer Unit Head Cable.62Table 6-7. Main PCB to Printer Unit Motor Film Cable..62Table 6-8. Main PCB to Printer Unit Motor Film Cable..62Table 6-9. Main PCB to SMPS Module Cable63Table 6-10. SMPS to Battery Cable.63Table 6-11. SMPS to Battery Cable.63Table 7-1. YM412i Part List..67 This page is intentionally left blank.Information YM412i Service Manual9 Chapter 1. Information Information 10YM412i Service Manual 1. General Information TheproductYM412ibearstheCEmarkingindicatingitsconformitywiththe provisionsoftheCouncilDirective93/42/EECconcerningmedicaldevicesandfulfillsthe essential requirements of Annex I of this directive. It is class a (MDD) equipment. TheproductisdesignedtocomplywithIEC60601requirements.ItisaprotectionclassI, type CF device. TheproductcomplieswiththeelectromagneticimmunityrequirementsofstandardIEC 60601-1-2/EN 60601-1-2 Electromagnetic Compatibility Medical Electrical Equipment. Theradio-interferenceemittedbythisdeviceiswithinthelimitsspecifiedin CISPR11/EN55011, class B. Thismanualcontainsserviceinformation;operatinginstructionsareprovidedintheuser manual of the instrument. This manual is for users who handle preventive maintenance, periodic operational checks, and basic troubleshooting for YM412i cardiograph. Before attempting to service the cardiographs, you must review the YM412i operators manual. Mediana considers itself responsible for the effects on safety, reliability, and performance of the equipment, only if; assembly operations, extensions, readjustments, modifications, or repairs are carried out by Mediana or by persons authorized by Mediana, the electrical installation of the relevant room complies with the applicable national and local requirement, and the instrument is used in accordance with the instructions for use. Warning Indicates a hazard. If not avoided, the hazard can result in death or serious injury. Caution Indicates a potential hazard. If not avoided, this hazard may result in minor personal injury and/or product/property damage. Information YM412i Service Manual11 2. Safety Information It is strongly recommended that the user first review this document thoroughly before operating the system. Warning:WhenoperatingthecardiographonACpower,ensurethatthe cardiograph and all other electrical equipment connected to or near the patient are effectively grounded. Warning:Useonlygroundedpowercords(three-wirepowercordswith grounded plugs) and grounded electrical outlets. Warning:If asafegroundconnectionisnot ensured,operatethe cardiograph on battery power only. Warning: Do not open or close the equipment on your own. Warning: Periodically inspect the patient cable, lead wires, and AC power cord for any worn or cracked insulation. Warning: Keep the patient cable away from power cords and ay other electrical equipment. Failure to do so can result in AC power line frequency interference on the ECG trace. Warning:TheMedianapatientcable(suppliedwiththecardiograph)isan integral part of the cardiograph safety features. Use of any other patient cable maycompromisedefibrillationprotectionanddegradecardiograph performance. Warning:Onlyqualifiedpersonnelmayservicethecardiographormayopen thecardiographhousingtoaccessinternalcardiographcomponents.Donot open any covers on the cardiograph. All internal components must be serviced by qualified personnel. Warning:Donotusethiscardiographnearflammableanesthetics.Itisnot intended for use in explosive environments or in operating rooms. Information 12YM412i Service Manual Warning:Donottouchthepatient,patientcable,orcardiographduring defibrillation. Death or injury may occur from the electrical shock delivered by the defibrillator. Caution: During repairs/service interventions, observe the protective measures against damage due to ESD (electrostatic discharge). Caution: Only use patient electrodes that are approved by Mediana. The use of non-approved patient electrodes may degrade cardiograph performance. Caution:Forcontinuedprotectionagainstriskoffire,replaceonlywithsame type and rating of fuse. Caution:Ifinternalbatterycablehasbeendisconnected,payparticular attention to polarity of the cable before reattaching. If battery cable polarity is reversed, it is likely that circuit damage will occur. Introduction YM412i Service Manual13 Chapter 2. Introduction Introduction 14YM412i Service Manual 1. Device description ThepurposeandfunctionofYM412iproductistodiagnoseelectrocardiogram,whichis designedforeasyoperation.ECGwaveformsaredisplayedonthegraphicLCD,andthe displayed waveforms can be printed with the built-in thermal printer. Also the YM412i product canbeconnectedtoapersonalcomputerbasedCardiologyInformationSystemtostore information on patients and ECG data. Introduction YM412i Service Manual15 Thesectionshowstop,sideandrearviewsoftheYM412i.Foradditionaldetails,seethe Operators manual. ThermalPrinterKeypadGraphicLCD Figure 2-1. Top Panel Figure 2-2. Rear Panel Figure 2-3. Right Panel Introduction 16YM412i Service Manual 2. Standard Accessories Table 2-1. List of Components YM412i Main 1EA Clamp Electrodes 1Pack Chest Electrodes 1Pack Patient Cable 1EA Power Cable 1EA Thermal Paper 1Pack Serial Cable 1EA Ground Cable 1EA Operators manual 1EA Service manual 1EA NOTE: The above pictures vary from the original in some points. Introduction YM412i Service Manual17 3. Contacting a Mediana Service Center TheMedianaServiceCentercanassistwithproducttroubleshootingandprovide technicalexpertisetohelpwithanyissuewiththeYM412icardiographoranyofits accessories. TEL+82-33-742-5400 FAX+82-33-742-5618 Introduction 18YM412i Service Manual This page is intentionally left blank.Basic Care and Maintenance YM412i Service Manual19 Chapter 3. Basic Care and Maintenance Basic Care and Maintenance 20YM412i Service Manual 1. Description Thischaptercontainsinformationonbasiccardiographcareandperiodicmaintenance.If furthertechnicalassistanceisrequired,contacttheMedianaServiceCenter.Basiccleaning and maintenance guidelines are also included in the Cleaning and Maintenance chapter of the YM412i Operators manual. 2. Cleaning Warning:Donotspray,pourorspillliquidmaterialsontheproduct, accessories,connectors,switchesorcases.Anddonotwashtheproductor the accessories with soluble or invasive liquid. For wash the product, wipe the surface lightly with a soft cloth, soaked with ageneral-use or non-invasivedetergent.Whilewashing,makeitsurethatanyliquidmaterialshouldnot infiltrateintoconnectorsorcovers.Equivalentattentionshouldbepaidtocablesand accessories. 1) Cleaning the Cardiograph When cleaning the equipment, wipe it with sponge, soft cloth or something like that wetted with soapy water and never use the detergent using alcohol, ammonia or acetone as main ingredients. Whencleaningtheequipment,payspecialattentionsothatcleaningliquidorsomething like that may not soak into the inside of equipment. Caution:Whencleaning,avoidtheleadwireconnectorsandpatientcable connectors. Caution: Do not use strong solvents or abrasive cleaning materials. Caution: Do not spill liquids on the surface of the cardiograph. Caution: Do not use any of the following to clean the cardiograph: -Acetone,Iodine-basedcleaners,Phenol-basedcleaners,Ethyleneoxide Basic Care and Maintenance YM412i Service Manual21 sterilization, Chlorine bleach, Ammonia-based cleaners 2) Cleaning the Patient Cable and Electrodes Caution: Do not use isopropyl alcohol. Caution: Do not use abrasive materials. Caution: Do not wet the connectors. To clean the patient cable and lead wires Dampen a soft cloth with soapy water or with one of the disinfectants or cleaning agents list below. Clean patient cable and lead wires with any of the following: - Cidex Ortho Phthaladehyde - Cetylcide - Vesphene 2 Aqueous Phenolic Germicidal Agent Wring excess moisture from the cloth before cleaning. 3) Cleaning the Printer Head - Unclean printer head can be cause of reducing print quality. - Open the printer cover and then wipe it softly without rubbing it too hard by wetting swab with 90% alcohol. - After cleaning, dry printer head sufficiently and then use it. Figure 3-1. Cleaning the printer head Basic Care and Maintenance 22YM412i Service Manual 3. Replacing Printer Paper Paper should be replaced in case red lines appear on paper when the ECG report is printed. Only use Mediana replacement printer paper. 1) Open the cover of a printer to remove the finished paper. Be careful not to throw away the paper guide inserted in the roll of paper, which is to be reused. 2) Insert the paper guide into a new roll of paper to place the roll at the center of the printer. 3) Unroll the paper slightly to put it on the printer roller, close the cover and test if the printer works normally. Figure 3-2. Changing Printer Paper Basic Care and Maintenance YM412i Service Manual23 4. Battery maintenance and care Charging the battery will be required if the YM412i product has not been used for a long time. Connect the device to the AC power source for charging the battery. Battery life varies depending on frequency of use and maintenance. For improved battery life, keepthecardiographpluggedinwhennotinuse.Ifthebatteryhasbeenfullychargedand requires recharging after a few ECGs, consider replacing it. For optimal battery performance: Only use Mediana Ni-MH battery. Keep the cardiograph plugged in when not in use. Caution: The battery should be removed form the unit and placed in storage if the cardiograph will not be used for more than 2 months. To replace or remove the battery, refer to Chapter 6. Disassemble Guide. Caution:Repeatedunderchargingofthebatterywilldamageandreduce battery life. Caution:Followlocalgovernmentordinancesandrecyclinginstructions regarding disposal or recycling of device components, including batteries. NOTE:ThecapacityofabatterywillbedecreasediftheYM412iproducthasnot beenusedforalongtimewithoutchargingit.Ittakesaround6hourstochargea battery, and it is necessary to discharge and charge a battery regularly for recovery to thenormalbatterycapacity.MedianarecommendsthattheNi-MHbatteryforYM412i productshouldbereplacedeverytwoyears.PleaserefertotheChapter6. Disassembly Guide for more information. Basic Care and Maintenance 24YM412i Service Manual 5. Firmware Upgrade Thissectionisforthepurposeforreloadingfirmwareinthedevicewhenthepossibilityof corruptedfirmwareexists,orupgradingfirmwarewithanewsystemversion.TheUSB Memory required for firmware upgrade. Caution: When a new firmware uploading is completed, the device is set to the default. Caution: If any problem during Firmware upgrade, contact the Mediana service center. It may be fail in according with the type of USB memory. 1) Turn the device off. 2) The new firmware (Folder name: Y412update) inserted in the USB memory. 3) Connect the USB memory and device. 4) After turn on the YM412i, booting screen appears. Before finish the booting screen, press ESC(ESC) and then press ENTERRUN(Enter). 5) The device will display the firmware update screen as shown below figure 3-3. 6) The firmware upgrades by it self. Figure 3-3. Firmware upgrading Screen 7) After completion of upgrade, turn the device off. After a few seconds, turn on again. 6. Cardiograph and Accessory Disposal Whenthecardiographhasreachedtheendofitsproductlife,disposeifitaccordingtolocal ordinance.Whenanyofthecardiographaccessoriesreachtheendoftheirproductlife, dispose of these items in accordance with local ordinances. Performance Verification and Safety Tests YM412i Service Manual25 Chapter 4. Performance Verification and Safety Tests Performance Verification and Safety Tests 26YM412i Service Manual 1. Description This chapter describes the tests and inspections required to verify performance of the YM412i following a service event. TheperformanceverificationtestsverifyproperoperationoftheYM412ifollowingaservice event. The level of testing required corresponds to the type of service performed. 2. Test Equipment ThefollowingtestequipmentisrequiredtoperformthecompletesetofPerformance Verification tests: ECG Simulator Digital Multi Meter Electrical Safety Tester ECG patient cable 3. Performance Verification Tests 1) Visual Inspection 1. Inspect the cardiograph external surfaces for the following: Worn or damaged power cord Loose or missing hardware Mechanical damage Evidence of liquid spill Worn printer drive gear Worn printer roller Corroded or damaged reusable electrodes Damaged patient leads Dirt or paper residue on the thermal print head Frayed or damaged wiring Visible LCD display damage 2. Replace any damaged or missing items. 3. Clean the patient cable as necessary. See Chapter.3 Basic care and maintenance. 2) Power on test To process a completed power in test, you must completely reboot the cardiograph. 1.Connect the cardiograph to AC power source using proper power cord. 2.Verify AC IN( ) and Battery( ) in indicators is lit. 3.Press Power button, and then verify that the cardiograph is turned on. 4.Verify Power ON( ) in indicator is lit. 5.After the cardiograph operates in normal mode, disconnect the power cord. 6.Verify AC IN( ), Battery( ) indicator is off, and Power ON( ) indicator is lit. 7.Press Power button, and then verify that the cardiograph is turned off. Performance Verification and Safety Tests YM412i Service Manual27 Table 4-1 Top panel indicators for power source Power ConnectionsTop panel Indicator illuminate AC IN Power OFF Fully charged battery AC IN Power ON Fully charged battery AC OUT Power ON Battery operation 3) Charging Battery Follow the below instruction for full battery charge. 1.ConnecttheelectriccordtotheACpowersourceofthedevice,andthenconnectthe electric cord to the external power supply. 2.WhentheACpowercordispluggedin,thebatteryautomaticallybeginstocharge.Fully charged battery will not do change. The charging battery can be automatically charged by inputting AC power; yellow LED onflashes while charging is under progress, and then the flashing stops when charging is completed. 3.Charge the battery for more than 6 hours. Regular full charge and discharge is required for recovery to the normal capacity. 4.Follow the below Battery Functional Test to check the full charge. Table 4-2 Battery Charging Status Indications Battery conditions Battery charging status indicator( ) Full chargedOn ChargingFlashing OperationOff Performance Verification and Safety Tests 28YM412i Service Manual 4) Battery Functional Test Basically this YM412i product can be operated for more than 90 minutes at the temperature of 25 on condition that the printer is not to be used. Before testing these functions, the battery should be fully charged. Caution:Whenthebatteryusingmorethan6months,willgraduallyreduce battery life. 1.Connect ECG simulator to the YM412i product. 2.AdjusttheECGsimulatorsothattheheartratebecomes60bpmandtheamplitude becomes 1mV. 3.ConnecttheelectriccordtotheACpowersourceofthedevice,andthenconnectthe electric cord to the external power supply. 4.Press the Power button on the product and check if the indicator is lit. 5.Check if a signal of the ECG simulator is displayed on the LCD screen. 6.The device should be operated for more than 90 minutes. 7.The device should generate ECG graphs more than 30 times. 8.Check if a message of Battery Low is displayed before the full discharge. 9.Press the Power button to stop operation. 10.If device passes this test, immediately recharge battery. 5) LCD Test 1. MENU Maintenance 2.Moveshadowbox( )totheMaintenance,andpress(ENTER)keytoshowthe password input window. 3. Input the password 1560, and press (Enter) to show the maintenance window. Performance Verification and Safety Tests YM412i Service Manual29 Figure 4-1. Maintenance Menu Screen 4.ToverifyoroptimizecardiographLCDstate,usetheLCDtest.Moveshadow box( ) to LCD Test, and press (ENTER) key to display the test screen. If something is the matter with the LCD, contact qualified service personnel or Mediana service center. 6) Printer Test 1. MENU Maintenance 2.Moveshadowbox( )totheMaintenance,andpress(ENTER)keytoshowthe password input window. Performance Verification and Safety Tests 30YM412i Service Manual 3. Input the password 1560, and press (Enter) to show the maintenance window. 4. The Printer Test is used to verify that the cardiograph printer is able to correctly print the test page. 5. Use this to verify proper printer performance or when reports appear to have print quality errors. 6.Moveshadowbox( )toPrinterTest,andpress(ENTER)keytoprinttheprinter test page. 7.Ifsomethingisthematterwiththetestpage,cleantheprinterheader.Themethodof printer cleaning refers to Chapter 3. Basic care and Maintenance. 8.ContactqualifiedservicepersonnelorMedianaservicecenter.ifproblempersistsafter printer header cleaned. 7) ECG Simulation 1.Connect the YM412i product to the AC power supply. 2.Press the Power button on the product. 3.Connect Mediana ECG cable to ECG cable connector on the cardiographs right panel. 4.Set ECG simulator as follows; Heart rate: 60bpm Amplitude: 1mV Normal sinus rhythm 5.After a few seconds, check if ECG waveforms are displayed on the LCD screen. 6.Select Automatic Mode and then press RUN button to start printing. 7.Verify the following when printing is complete: Traceactivityforall12leads.Noiseshouldmeasurelessthan1mm,withno baseline wander. No gross distortion of complexes or calibration pulses Calibration pulse amplitude is correct. NOTE: Noise may be an artifact of poor connections to the simulator or position of the cables. If noise appears, check the connectors or adjust the cable drape. Performance Verification and Safety Tests YM412i Service Manual31 4. Safety Test This section explains tests of the cardiographs electrical safety. The suggested Safety Analysis Tests refer to the international standard IEC60601-1, Clause 19. The tests are generally performed with Safety Testers, on most of them, the measuring circuits according IEC60601-1 are already implemented. The following is a general description of the tests to be performed. Thetestsmaybeperformedundernormalambientconditionsoftemperature,humidityand pressure and with line voltage. Test both Normal and Reverse polarity line connections for each test, and record the worst-case value. Ifagroundreferencepointisneededforthetesting,usethemetalgroundingstudinthe back of the cardiograph. 1) Protective Earth Resistance This test checks the integrity of the power cord ground wire from the AC plug to the instrument chassis ground. The current used for this test is less than or equal to 4Volts RMS, 50 to 60Hz, and 25Amperes. 1.ConnectthedeviceACmainsplugtotheanalyzerrecommendedbytheanalyzer operating instructions. 2.Connect the analyzer resistance input lead to the equipotential terminal on the rear of the device. Verify that the analyzer indicates 100milliohms or less. 2) Leakage Current - Earth Leakage Current ThistestisincompliancewithIEC60601-1earthleakagecurrent.Theappliedvoltagefor IEC60601-1 the voltage is 264V AC, 50-60Hz. 1.ConnectthedeviceACplugtotheelectricalsafetyanalyzerasrecommendedbythe analyzer operating instructions. 2. Perform the test as recommended by analyzer operating instructions. 3. Earth leakage current is measured under various condition of the AC mains and protective earthconductor.Foreachcondition,themeasuredleakagecurrentmustnotexceedthat indicated in Table 4-1. Table 4-3. Earth Leakage Current Values ConditionAllowable Leakage Current (microamps) Normal Condition500 Single Fault Condition1000 3) Leakage Current - Patient Leakage Current ThistestisperformedaccordingtoIEC60601-1StandardsontheClassICFtypeddevices. Patient leakage current in this test is measured from any individual patient connection to earth (power ground). Performance Verification and Safety Tests 32YM412i Service Manual 1.Settheelectricalsafetyanalyzerasrecommendedbytheelectricalanalyzersoperating instructions. 2.ConnectthedevicesACmainspowercordtotheelectricalanalyzerasrecommendedby the electrical analyzers operation instructions. 3.ConnectECGtestcablebetweenECGconnectoronthedeviceandappropriateinput connector on analyzer. Turn on the YM412i device. 4. Perform the test as recommended by analyzer operating instructions. 5.Patientleakagecurrentismeasuredwithnormalandreversemainspolarity.Foreach condition, the measured leakage current must not exceed that indicated in Table4-2. Table 4-4. Patient Leakage Current Values ConditionAllowable Leakage Current (microamps) Normal Condition10 Single Fault Condition50 4) Leakage Current Patient Leakage Current (Mains Voltage on the Applied Part) This test is performed according to IEC60601-1 Standards on the Class I CF typed devices. In this test, 110% of mains voltage is applied between each patient connection and earth (power ground).Patientleakagecurrentisthenmeasuredfromanyindividualpatientconnectionto earth. 1.Settheelectricalsafetyanalyzerasrecommendedbytheelectricalanalyzersoperating instructions. 2.ConnectthedevicesACmainspowercordtotheelectricalanalyzerasrecommendedby the electrical analyzers operation instructions. 3.ConnectECGtestcablebetweenECGconnectoronthedeviceandappropriateinput connector on analyzer. Turn on the YM412i device. 4. Perform the test as recommended by analyzer operating instructions. 5.Patientleakagecurrentismeasuredwithnormalandreversemainspolarity.Foreach condition, the measured leakage current must not exceed that indicated in Table4-3. Table 4-5. Patient Leakage Current Values-Mains Voltage on Applied Part ConditionAllowable Leakage Current (microamps) Normal polarity (Single Fault Condition)50 Reverse polarity (Single Fault Condition Reverse Mains Voltage) 50 Performance Verification and Safety Tests YM412i Service Manual33 5) Patient Auxiliary Current ThistestisperformedaccordingtoIEC60601-1StandardsontheClassICFtypeddevices. TheappliedvoltageforIEC60601-1thevoltageis264V,50-60Hz.Patientauxiliarycurrentis measured between each ECG test lead. 1.Settheelectricalsafetyanalyzerasrecommendedbytheelectricalanalyzersoperating instructions. 2.ConnectthedevicesACmainspowercordtotheelectricalanalyzerasrecommendedby the electrical analyzers operation instructions. Table 4-6. Allowable Leakage Current ConditionAllowable Leakage Current (microamps) Normal Condition10 Single Fault Condition50 Performance Verification and Safety Tests 34YM412i Service Manual This page is intentionally left blankTroubleshooting YM412i Service Manual35 Chapter 5. Troubleshooting Troubleshooting 36YM412i Service Manual 1. Description ThischaptersuggeststroubleshootingtipsforproblemswithYM412i.Thebelowtableswill show the possible problems of the device and the recommendable troubleshooting procedures. 2. Service Technicians Onlytechnicallyqualifiedserviceoperatorscancarryoutdisassembly&adjustmentofa device and removal & replacement of parts. In case a qualified service operator is not available, contact the Mediana Service Center. 3. Replacement Support The replaceable parts of this product are PCBs, main assemblies and some parts. If a PCB is consideredtobedefect,replaceitwithanewoneaccordingtotheChapter6Disassembly Guide.Checkiftheerroriscorrectedafterreplacementandcarryoutallfunctionaltests.In casetheerrorstillhappens,replacethenewPCBwiththeoriginaloneandfindanother solution as instructed in this chapter. 4. Getting Replacement Parts Medianaprovidestechnicalsupportandreplacementparts.Togetareplacementpart,users cancontacttheMedianaServiceCenter,referringtotheChapter5ReplacementPartsfor part names and numbers. 5. Troubleshooting Topics The following table lists all of the Troubleshooting topics included in this chapter. NOTE:Thetroubleshootingtipsinthischaptercoverthemaintroublesthatusers possiblyencounter.Forotherproblems,notincludedinthesetroubleshootingtips, contact the Mediana Service Center. Warning: Electrical shock hazard. Disconnect a power cord from YM412i before attempting to open or disassemble YM412i. Troubleshooting YM412i Service Manual37 Table 5-1 Troubleshooting Topics TopicSymptom Batteries and AC Power 1.WhenACpowercordisconnectedtothedevice,ACindicatoronthe front panel is not lit. 2.PowerisnotonwhenpressingthePOWERbuttoninconditionthe external AC power line is connected to the device. 3.The device does not operate when disconnected from AC power. 4. Battery does not charge. Display 1.Screen is totally black color or white color (no data is visible) when the power is turned on. 2.Data (signal & text) is not shown even though the screen is normal. 3.Backlight is not activated while data is displayed on the screen. 4.Display values are missing or erratic. Button 1.Buttons do not respond. 2.Some of buttons do not work tough the power is turned on. Beep1. Audible beep does no sound. Printer 1.Printerdoesnotresponseeventhoughprintingrelatedbuttonsare pressed. 2.Printergeneratesemptypaperevenincasetheprintermotorworks and the printing paper is loaded. Other 1. One lead signal or more come out in straight lines or too much noise is generated. 2. One leads signal or more come out in straight lines or too much noise is generated. Troubleshooting 38YM412i Service Manual 6. Battery and AC Power ThefollowingtabledescribescommonproblemswithbatteriesandACpower.Iftheaction requires replacement of the components, refer to [Chapter 6. Disassembly Guide]. Table 5-2 Battery and AC Power Troubleshooting SymptomSolution 1.WhenACpowercordis connected to the device, AC indicatoronthefrontpanel is not lit. 1-1 Ensure power cord is plugged into the appropriate AC outlet of voltage and frequency. 1-2 Replace the AC fuse. 1-3 Check the main cable and ensure that it is connected to the main board and the power module. 1-4 If indicator is not lit, replace the main cable. 1-5 If the problem persists, replace the power module. 1-6Iftheproblempersists,ensurethekeypadcableis connectedtothekeypadassemblyandthemainboard.If connection is good, replace the keypad. 2.Powerisnotonwhen pressingthePOWER buttoninconditionthe externalACpowerlineis connected to the device. 2-1 Ensure power cord is plugged into the appropriate AC outlet of voltage and frequency. 2-2 Ensure AC power indicator is lit. If indicator is not lit, replace the power module. 2-3 Replace the AC fuse. 2-4 Check the main cable and ensure that it is connected to the main board and the power module. 2-5Ensurethekeypadisconnectedtothemainboard.If connection is good, replace the keypad. 2-6 If the problem persists, replace the main board. 3.Thedevicedoesnot operatewhendisconnected from AC power. 3-1Thebatterymaybedischarged.Torechargethebattery, connect a power cord to AC mains over 6hours. 3-2 Check the main cable and ensure that it is connected to the main board and the power module. 3-3Thebatterymaybeoverheated.Afterithasdropped, operate the device. 3-4 If the problem persists, replace the battery. 3-5 If the problem persists, replace the main board. Troubleshooting YM412i Service Manual39 4. Battery does not charge. 4-1Ensurethekeypadisconnectedtothemainboard.If connection is good, replace the keypad. 4-2 If the battery fails to hold a charge, replace the battery. 4-3VerifytheACINLEDislit,whileonAC.Whilecharging battery,theBatteryLEDisflasheduntilbatterychargingis completed. When the battery charging is completed, the Battery LEDislitcontinuously.ReplacethepowermoduleiftheLEDs are not lit. Troubleshooting 40YM412i Service Manual 7. Display Thefollowingsaresymptomsofproblemsrelatingtonon-functioningdisplays,and recommended action. If the action requires replacement of a PCB assembly or module, refer to Chapter 6. Table 5-3 Display Troubleshooting SymptomSolution 1.Screenistotallyblackor whitecolor(nodatais visible)whenthepoweris turned on. 1-1 Check the backlight cable and the data cable are connected to the STN-SUB PCB. 1-2ChecktheSTN-SUBPCBconnectorisconnectedtothe main PCB 1-3 If problem persists, replace the STN-SUB PCB. 1-4 If problem persists, replace the LCD module. 1-5 If problem persists, replace the CPU module. 1-6 If problem persists, replace the main board. 2. Data (signal & text) is not showneventhoughthe screen is normal. 2-1 Check the backlight cable and the data cable are connected to the STN-SUB PCB. 2-2ChecktheSTN-SUBPCBconnectorisconnectedtothe main PCB 2-3 If problem persists, replace the STN-SUB PCB. 2-4 If problem persists, replace the CPU module. 2-5 If problem persists, replace the LCD module. 2-6 If problem persists, replace the main board. 3.Backlightisnotactivated whiledataisdisplayedon the screen. 3-1 Check the backlight cable and the data cable are connected to the STN-SUB PCB. 3-2ChecktheSTN-SUBPCBconnectorisconnectedtothe main PCB 3-3 Replace the STN-SUB PCB if problem persists. 3-4 Replace the LCD module if problem persists. 3-5 Replace the main PCB if problem persists. 4.Displayvaluesare missing or erratic. 4-1Ifthepatientcablesareconnected,ensurethatthecables are properly connected. 4-2 Verify position of the leadwire, re-setting the filter. 4-3 AC supply may be wrong, operate the battery and check. 4-4 If problem persists, replace the patient cable. 4-5 If problem persists, replace the LCD module. 4-6 If problem persists, replace the main board. Troubleshooting YM412i Service Manual41 8. Button Thefollowingisasymptomofproblemsandrecommendedactionsrelatingtobuttons.Ifthe action requires replacement of a PCB assembly, refer to Chapter 6. Table 5-4 Button Troubleshooting SymptomSolution 1. Buttons do not respond. 1-1 Check the keypad is properly connected to the main board. 1-2 Check the cable between main board and the keypad PCB. 1-3 If the cable abnormal, replace the cable. 1-4 If problem persists, replace the keypad PCB. 1-5 If problem persists, replace the main board. 2.Someofbuttonsdonot worktoughthepoweris turned on. 2-1 Check the keypad is properly connected to the main PCB. 2-2 Check the cable between main board and the keypad PCB. 2-3 If the cable abnormal, replace the cable. 2-4 If problem persists, replace the keypad PCB. 2-5 If problem persists, replace the main PCB. 9. Beep Thefollowingisasymptomofproblemsandrecommendedactionsrelatingtobeep.Ifthe action requires replacement of a PCB assembly, refer to Chapter 6. Table 5-5 Beep Troubleshooting SymptomSolution 1.Audiblebeepdoesno sound. 1-1 Check beep silence status. 1-2 Check beep setting in system setup menu. 1-3Checkthemaincablebetweenmainboardandthepower module. 1-4 If problem persists, replace the main board. Troubleshooting 42YM412i Service Manual 10. Printer Thefollowingisasymptomofproblemsandrecommendedactionsrelatingtoprinter.Ifthe action requires replacement of a PCB assembly, refer to Chapter 6. Table 5-6 Printer Troubleshooting SymptomSolution 1. Printer does not response eventhoughprintingrelated buttons are pressed. 1-1Opentheprintercoverandcheckifthepaperisproperly loaded. 1-2 Check the printer related connections are properly secured. 1-3 The printer header may be overheated. After it has dropped, operate the device. 1-4 If problem persists, replace the printer module. 1-5 If problem persists, replace the main board. 2.Printergeneratesempty paperevenincasethe printermotorworksandthe printing paper is loaded. 2-1Opentheprintercoverandcheckthepaperisproperly loaded. (Only one side of paper is effective thus it will not work if the opposite side is loaded.) 2-2 If problem persists, replace the printer module. 2-3 If problem persists, replace the main board. Troubleshooting YM412i Service Manual43 11. Others Table 5-7 Others SymptomSolution 1.Oneleadsignalormore comeoutinstraightlinesor toomuchnoiseis generated. 1-1 Check the patient cable is properly connected to the device. 1-2 Check the filters are properly setting. 1-3 If problem persists, replace the patient cable. 1-4 if problem persists, replace the main board. 2. Leads II and III2-1 Check LL(or F) and RL(or N) lead wire and electrode. 3. Leads I and III3-1 Check LA(or L) and RL(or N) lead wire and electrode. 4. Leads I and II4-1 Check RA(or R) and RL(or N) lead wire and electrode. 5. V1-V6(C1-C6)5-1 Check V1-V6(C1-C6) and RL(or N) lead wire and electrode. Troubleshooting 44YM412i Service Manual This page is intentionally left blank.Disassembly Guide YM412i Service Manual45 Chapter 6. Disassembly Guide Disassembly Guide 46YM412i Service Manual 1. Description This chapter contains information on removing and replacing the YM412i components. Caution:DonotoperatetheYM412iproductrightafterrepairorexamination. Operatethedeviceaftercompletingallofthefunctionaltestsandsafety inspections described in the Chapter 3. Failure in the functional test may cause misreading. The following parts of the YM412i product can be disassembled. PCB Battery Cables Printer Case The following tools are used for disassembly. Screwdriver (manual or automatic) Needle - Nose Pliers Torque Warning:Electricalshockhazard.Besuretodisconnectthemainpower supply from the device before disassembling the YM412i product. Warning:Ahigh-voltagecanbegeneratedfromtheLCDbacklightdriver.Be careful when opening the cover. Caution:Incasetheinternalbatterycableisnotconnected,specialattention shouldbepaidtothepolarityofthepowersupply.Ifthepolarityisreversed, the circuits may be damaged. NOTE:Togetmainreplacementparts,contacttheheadofficeofMedianaService Center. Disassembly Guide YM412i Service Manual47 2. How to Use Disassembly Guide Warning:Beforeattemptingtoopenordisassembletheelectrocardiograph, disconnect the power cord from the electrocardiograph. Caution:ObserveESD(electrostaticdischarge)precautionswhenworking within the unit. To find a replacement part of the YM412i product, follow the step-by-step procedure of the flow charts described in Figure 6-1, 6-2 and 6-3. As described in the flow charts, the disassembleable parts are basically sorted into the upper case assembly part and the lower case assembly part. The main PCB assembly is separated fromthelowercaseassembly.Forthelistofreplaceableparts,refertotheChapter7 Replacement Parts. The disassembly flow charts can be referred for removal or replacement of abnormal parts and partial assemblies. For more detailed information on disassembly, refer to the diagrams of the appendix. 3. Disassembly Flow Chart ThebelowdisassemblychartisavailableonlyfortheYM412iproduct.Andthechartis prepared for the qualified service operators approved by Mediana, which is composed in direct manner for troubleshooting. Figure 6-1. Disassembly Flow Chart Disassembly Guide 48YM412i Service Manual Figure 6-2. Upper Case Disassembly Disassembly Guide YM412i Service Manual49 Main PCBPower ModuleDetach the cable between main PCB and power module.Detach the cable between main PCB and power module.Lower CaseBatteryPrinterRemove screws from battery bracketRemove screws from printerDetach connectors from PCBDetach battery bracketRemove screws from power moduleRemove screws from PCB.Remove ground terminal from case.CPU ModuleDetach CPU Module CapDetach the CPU Module from Main PCB Figure 6-3. Lower Case Disassembly Disassembly Guide 50YM412i Service Manual 4. Disassembling Cases Thischaptershowsthedisassemblyprocedures,throughpictures,forreplacementofthe assembliesorthepartsoftheYM412iproductthatareconsideredtobedefectordamaged. Some of the explanatory procedures contain pictures of the replacement parts. 5. Opening the device ToopentheYM412ireleasethe4fasteningscrews(M3x8)ontheundersideofthedevice, carefully raise the upper shell of the housing, disconnect keypad and LCD cable. Figure 6-4 Detaching the Upper and Lower case Disassembly Guide YM412i Service Manual51 6. Lower Case Disassembly Main Board, CPU Module, Power Module, Battery, Printer 1) Removing and Replacing the Battery 1. Disconnect the battery connector from the power module. 2. Remove 4 fastening screws (M3x6) from battery bracket. 3. Separate the battery bracket and battery. 4. Insert the new battery into the battery bracket. Figure 6-5 Battery Disassembly Disassembly Guide 52YM412i Service Manual 2) Removing and Replacing the Printer 1.Disconnect the printer film cable and motor film cable from the main board. 2.Remove 2 fastening screws (M2.6x8) from lower case. Figure 6-6 Thermal Printer Disassembly Disassembly Guide YM412i Service Manual53 3) Removing and Replacing the Main Board 1.Detach the connection cable between main PCB and power module. 2.Remove 12 fastening screws (CPU module 4 screws: M3x5, Main board 8 screws: M3x6) from lower case. Figure 6-7 Main Board Disassembly 4) Removing and Replacing the Fuse 1. Remove 2 AC main fuses (250V/6.3A) out of the socket if required. 2. Replace new fuse. Figure 6-8 Fuses replacement Disassembly Guide 54YM412i Service Manual 5) Removing and Replacing the Power Module 1.Detach the connection cable between main PCB and power module. 2.Remove the GND terminal from lower case. 3.Remove 5 fastening screws (M3x6) from lower case and detach the power module. Figure 6-9 Power Module Disassembly Disassembly Guide YM412i Service Manual55 6) Replacing the CPU Module 1.Remove 4 fastening screws (M3x5) from lower case. 2.Detach the CPU module cap from main board. 3.Remove 4 supports male type and 4 supports female type 4.Detach the CPU module from main board. Figure 6-10 Replacing the CPU Module Disassembly Guide 56YM412i Service Manual Table 6-1. Part Descriptions Lower Case Assembly Part CodesDescriptionsQty E00000-00Battery1 M05210-00Battery Bracket1 E50000-00Printer1 P05201-00Main Board1 P05202-00CPU Module1 M05211-00CPU Module Cap1 E41101-00Power Module1 -Screw23 Disassembly Guide YM412i Service Manual57 7. Upper Case Disassembly Keypad PCB, LCD, STN-SUB PCB 1) Removing and Replacing the Keypad PCB 1.Remove 4 fastening screws (M3x6) from upper case. 2.Disconnect the cable between keypad PCB and main board. Figure 6-11. Keypad Disassembly Disassembly Guide 58YM412i Service Manual 2) Removing and Replacing the LCD and STN-SUB PCB 1.Remove 8 fastening screws (M3x6) from upper case. 2.Disconnect the cable between LCD and STN-SUB PCB. 3.Disconnect the cable between STN-SUB PCB and main board. Figure 6-12. LCD and STN-SUB PCB Disassembly Disassembly Guide YM412i Service Manual59 Table 6-2. Part Descriptions Upper Case Assembly Part CodesDescriptionsQty P05203-00Keypad PCB1 H05212-00Cable between keypad PCB and main board1 E20001-00LCD1 P05204-00STN-SUB PCB1 H05211-00Cable between STN-SUB PCB and main board2 -Screw12 Disassembly Guide 60YM412i Service Manual 8. Specification of cables and connectors The tables in this section describe and show the specification of all cables in the YM412i. This table will be useful when reassembling and debugging. Table 6-3. Main PCB to Keypad PCB Cable Main PCBKeypad PCB J5J9 ColorDescription 11RedKey column 3 22GrayKey row3 33GrayKey column 2 44GrayKey row2 55GrayKey column 1 66GreenKey row1 77GrayKey column 0 88GrayKey row0 99GrayGND 1010GrayGND 1111GreenPower ON/OFF Key 1212GraySMPS Standby power 1313GrayAC power check indicator 1414GrayGND 1515GrayBattery charge indicator 1616GreenPower ON Indicator Disassembly Guide YM412i Service Manual61 Table 6-4. Main PCB to STN-SUB PCB Data Cable Main PCBSTN SUB PCB J10J13 ColorDescription 11Red+5V VDD 22GrayBack light unit Power 33GrayGND 44GrayGND 55GrayVSYNC 66GreenVideo Data 0 77GrayVDE 88GrayVideo Data 1 99GrayHSYNC 1010GrayVideo Data 2 1111GreenVCLK 1212GrayVideo Data 3 1313GrayLCD Enable 1414GrayGND 1515GrayGND 1616GreenContrast control 1717Gray-20V STN 1818GrayGND 1919GrayGND 2020GrayGND Table 6-5. STN SUB PCB to LCD Back Light Cable STN SUB PCBLCD BLU J2LCD Description 11GND 22N.C 33N.C 44OUT Disassembly Guide 62YM412i Service Manual Table 6-6. Main PCB to Printer Unit Head Cable Main PCBPrinter unit PJ5Head Description 1, 21,221, 21,2211V Header power 22NC 33Header data Latch signal. 44Header CLK 555V VDD 66Strobe signal 1 7,87,8Strobe signal 2 99Header thermistor 10,11,12,13,14,1510,11,12,13,14,15 GND 16,1716,17Strobe signal 2 18,1918,19Strobe signal 2 2020Data Table 6-7. Main PCB to Printer Unit Motor Film Cable Main PCBPrinter unit PJ2Motor Description 11Phase A 22Phase negative A 33Phase B 44Phase negative B Table 6-8. Main PCB to Printer Unit Motor Film Cable Main PCBPrinter unit PJ2Paper Sensor Description 11Phase A 22Bias 33Sensor out 44GND Disassembly Guide YM412i Service Manual63 Table 6-9. Main PCB to SMPS Module Cable Main PCBSMPS WJ2CJ3 ColorDescription 11RedBATT Level Signal 22GrayBattery charging status signal 33GrayAc check signal 44GrayMain DC/DC ON/OFF Signal 55GrayGND 66GreenSMPS Standby 16V 77GraySTN Negative Power 88GraySTN Negative Power 99GrayGND 1010GrayGND 1111GreenThermal Printer Header VCC 1212GrayThermal Printer Header VCC 1313GrayGND 1414GrayGND 1515GrayThermal printer Motor VCC 1616GreenThermal printer Motor VCC 1717GrayGND 1818GrayGND 1919Gray5V 2020Gray5V Table 6-10. SMPS to Battery Cable SMPSBattery CN2 ColorDescription 1+RedBattery( +) 2TBlueThermistor 3-BlackBattery(-) Table 6-11. SMPS to Battery Cable SMPSGNDColorDescription Power inlet earth terminal GND TerminalGreen & YellowGND Disassembly Guide 64YM412i Service Manual This Page is intentionally left blank. Parts List YM412i Service Manual65 Chapter 7. Parts List Part List 66YM412i Service Manual 1. Description Thischapterprovidesinformationonorderingreplacementparts,supplies,andaccessoriesfortheYM412icardiograph.Toorderreplacement parts, contact Mediana Service Center. Figure 7-1. YM412i Parts Parts List YM412i Service Manual67 Table 7-1. YM412i Part List No.Part CodesDescription 1L05203-00Keypad Overlay 2L05202-00LCD Overlay 3C05250-00Thermal Printer Cover 4E60000-00Thermal Printer Roller 5C05210-00Upper Case 6E20001-00LCD 7P05203-00Keypad 8P05204-00STN-SUB PCB 9M05210-00Battery Bracket 10E00000-00Battery 11E50000-00Thermal Printer Body 12P05201-00Main Board 13E41101-00Power Module 14M05200-00GND Terminal 15-GND Washer 16-GND Nut 17C05211-00Lower Case 18M05211-00CPU Module Cap Part List 68YM412i Service Manual This Page is intentionally left blank. Packing YM412i Service Manual69 Chapter 8. Packing Packing 70YM412i Service Manual 1. Description Make it sure to pack products carefully according to the instructions in this chapter. Otherwise the products may be damaged or missing. In case the basic packing is not available, another proper packing can be applied. In case a user needs to pack a product and there is no proper packing material, contact the head office of Mediana or a local agent office. Be sure to mark the serial numbers on each packing unit and the shipping documents before the shipment of the products. For a recalled product from customers, the document describing the problems of the product should be enclosed. 2. Standard Carton Box Packing Thestandardcartonboxpackingishighlyrecommendedifavailable,andthepacking procedure is as follows; 1.Reinforce the lower side of a standard carton box with packing tapes. 2.Place the box containing accessories on the bottom of the standard carton box. 3.Put the product in an air cap envelope and install the supporting buffers on the both sides. Place the product in the standard carton box. The accessory box should be placed at the center the box. 4.Cover the product with a protecting cover and place manuals and shipping documents on the product. 5.Seal the upper side of the standard carton box tightly with packing tapes. 6.Complete the markings on the side of the standard carton box. 3. Repacking In case of the standard carton box is not available, follow the below packing procedure. 1.Prepare a box with a proper size. 2.Reinforce the lower side of the box with packing tapes. 3.Place the box containing accessories on the center of bottom of the packing box. 4.Fill the empty space of the both sides of the accessory box with buffing material. 5.Wrap the product with plastic wrap or put in a plastic envelope for keeping it clean. Place it on the inner center of the box. 6.Fill the empty space of left, right and upper part of the box with buffing material. 7.Seal the upper side of the box tightly with packing tapes. 8.Complete the markings on the side of the box. Specifications YM412i Service Manual71 Chapter 9. Specifications Specification 72YM412i Service Manual Display Type103mm(W) X 77.22mm(H) STN mono LCD Resolution320 X 240 dots Computerized Electrocardiograph ECG Storage Basic - 100 ECGs (typical) Option 5000 cases in SD Card (1GB) Pre-acquisitionProvides 10s of instantaneous ECG acquisition Dynamic Range AC differential: 5mV DC offset: 300mV Sampling Rate500Hz Frequency Response0.05 to 150Hz CommonMode Rejection 100dB Input Impedance> 50 PatientLeakage Current < 10 CommunicationPC communication with RS232 interface and LAN Firmware UploadUse the USB memory stick Filter AC: 50/60Hz Low Pass Filter: 40, 100, 150Hz Baseline Filter: 0.5Hz Muscle Filter Writer TypeThermal dot array Speeds5, 10, 25, 50mm/sec Numbers of Traces3, 6 or 12 user-selectable Sensitivity/Gain5, 10, 20mm/mV Speed Accuracy5% Amplitude Accuracy5% Paper Type/SizeThermal Roll, 110mm X 30m Specifications YM412i Service Manual73 Electrical Power SupplyAC or Battery operation AC Input100-240VAC 50/60Hz, 70VA FusesQty. 2, 250Vac T6.3AL, IEC(5x20mm) Battery Type 12V 3.8Ah, Rechargeable Nickel Metal Hydride Cylindrical Cell Battery Capacity 150basicreports(AutoMode)or5hourscontinuous operation (without printing) Battery Charge TimeApproximately 6hours from total discharge Physical Dimension351 X 268.5 X 63 (W x L x H) mm Weight2.7Kg (including battery) without paper Environmental Operating Conditions Temperature range 10-45 Humidity range 20%~95%(non-condensing) Atmosphere Pressure: 700 to 1060 hPa Storage/Transportation Condition Temperature range -20~60 Humidity range 10%~95%(non-condensing) Atmosphere Pressure: 500 to 1060 hPa Compliance ClassificationClass I, Internally powered Type of protectionType CF with defibrillation protection Mode of operationContinuous Degree of protectionIPX 0 93/42/EEC Directives for medical devices ISO9001:2000QualityManagementSystems-Requirements ISO13485:2003Medicaldevices-Qualitymanagement systems - Requirements regulatory purposes General ISO14971:2000Medicaldevices-Applicationofrisk management to medical devices Specification 74YM412i Service Manual IEC60601-1:1988+A1:1991+A2:1995General requirements for Safety IEC60601-1-4:1996+A1:1999GeneralRequirementsfor safetycollateralstandard:programmableelectrical medical systems ISO10993-1:2003Biologicalevaluationofmedical devices Part 1: Evaluation and testing Electrocardiograph IEC60601-2-25:1993+A1:1999 Particular requirements for the safety of electrocardiographs IEC60601, sub clause 36 IEC60601-1-2:2001+A1:2004Electromagnetic compatibility - Requirements and tests IEC61000-3-2:2000 Harmonic current emissions IEC61000-3-3:1995+A1:2001Voltagefluctuations/Flicker Emissions IEC61000-4-2:1995+A1:1998+A2:2001Electrostatic Discharge(ESD) IEC61000-4-3:2002+A12002RadiatedRF electromagnetic field IEC61000-4-4:2004 Electrical fast transient/burst IEC61000-4-5:1995+A1:2001 Surge current IEC61000-4-6:1996+A1:2001Conducteddisturbances, induced by RF field IEC61000-4-8:1993+A1:2001Powerfrequency(50/60Hz) magnetic field IEC61000-4-11:1994+A1:2001Voltagedips,short interruptionandvoltagevariationonpowersupplyinput lines Electromagnetic Compatibility CISPR11(EN55011) RF Emissions Group 1, Class B Labeling EN1041:1998Informationsuppliedbythemanufacturer with medical devices Marking EN980:2003Graphicalsymbolsforuseinthelabelingof medical devices Functional Description YM412i Service Manual75 Chapter 10. Functional Description Functional Description 76YM412i Service Manual 1. Description ThischapterprovidesfunctionaldescriptionsofthecomponentsoftheYM412iCardiograph. These descriptions are at the functional-block level. 2. System Overview TheYM412isystemperformsacquisition,analysis,printing,storage,andtransferofECG waveforms and other patient clinical data. 3. Hardware Functional View ControloftheYM412iisprovidedbyapplicationsoftwarerunningonthemaincontrolboard, interactingwithnumeroushardwareandsoftwaresubsystems.Thefollowingarehigh-level descriptions of these various subsystems. The hardware consists of the following function blocks: Main Board: B1 CPU Module: B2 STN-SUB Board: B3 Keypad Board: B4 Power Module: M1 LCD Module: M2 Battery Module: M3 Thermal Printer Module: M4 Figure 10-1. Block Diagram of Entire instrument Functional Description YM412i Service Manual77 1) Power System The YM412i power system contains the power module and battery. ApowermoduleconsistsofAC-DCConverter(AC/DC),DC-DCConverter(DC/DC)and Battery Charger. Battery PackNi-MH 1.2V 3800mAh 10CellFUSEFUSEAC/DCSwitchingPower Supply16VCharger with Charger Management MCUIndication LED DC/DC(Main Power)CONON/OFFRelay DC/DC(Thermal Printer Motor)DC/DC(Thermal Printer Header)DC/DC(LCDNegative power)FUSEConnectorConnectorMain BoardPowerControl SignalACLine PowerFILTERAC Inlet Figure 10-2. Power System Block Diagram Battery charging When the AC power cord is plugged in, the battery automatically begins to charge. The battery charging status transmitted the LED and TTL level signal. The battery is in connection the fuse and built in thermistor, thermostate for battery safety. Functional Description 78YM412i Service Manual 2) DC Power Supply YM412iprovidesthepowertoeachcircuitpartthroughthepowersystemlikethefollowing block diagram. Figure 10-3. DC Power Supply Block Diagram 16V Stand by Supply the 16V for power management unit. YM412i maintain the ready. +5V Main Power The +5V Main Power is a supplier of the 5V Logic, 3.3V Logic and Isolation analog power for overall system operation. +8.5V Thermal Printer Header Operation of the thermal printer header +7.5V Thermal Printer Motor Operation of the thermal printer motor -20V STN LCD Negative Power Operation of the STN LCD Functional Description YM412i Service Manual79 3) Main CPU Module MainCPUModulecontainstheprocessorS3C2440A,NORFlash,SDRAMandallsortsof hardware driver. CPU Module controls each system and performs management, analysis, display, printing and storage of acquisition data. Figure 10-4. Main CPU Module Block Diagram 4) RTC Power Interface The Li-lon battery and 3.3V supplies power for operation of Real Time Clock (RTC). Figure 10-5. RTC Power Interface Block Diagram Functional Description 80YM412i Service Manual 5) Display Interface The 320X240 STN mono LCD is handled by the LCD controller in the main process. Figure 10-6. Display Interface Block Diagram 6) Keypad Interface YM412iconsistofmultifunctionkeysoftennumberkeys(hotkeys)andsixfunctionkeys (direction keys). And keypad includes power on/off key and three indicators. S3C2440A Figure 10-7. Keypad Interface Block Diagram Functional Description YM412i Service Manual81 7) Thermal Printer Interface ThermalPrinterconsistsofThermalheaderandstepmotor.Eachdatacontrolledbymain processor and timing adjusted by CPLD and FIFO. Thermal Printer HeaderThermal Printer MotorLogic BufferData Bus& Control SignalGPIOSTB1STB2STB3STB4Data BusIO ControlLATDATACLKMotorPhaseMotor DriverCPLD FIFOCon. Sig.DataCon. Sig. Figure 10-8. Thermal Printer Interface Block Diagram 8) Communication Interface YM412ihaveinterfacemethodsoftheUARTserial,TCP/IPandUSBcommunication.Great capacity data can backup using the internal SD card (optional). SPIData BusTCP/IPStackCon. Sig.Data& ADD. BUSLAN Connector10/100 T InterfaceEternetPhyceiverUARTUSBRS-232DriverSerial UARTSD CARDUSB HOST Figure 10-9. Communication Interface Block Diagram Functional Description 82YM412i Service Manual 9) Analog Signal Acquisition Interface Acquisition data digitized by AD converter and then transfer to main processor. RL DriverSaturation DetecterDischarger+5VTXRXGPIOUARTIsolation barrier+5V-5V Figure 10-10. Analog Signal Acquisition Interface Block Diagram