EA660 Modular UPS Introduction 20KVA 400KVA 20KVA-400KVA

EA660 Modular UPS Introduction 20KVA-400KVA - lanches-ups.rulanches-ups.ru/doc/lanches_ea660_presentation.pdf · EA660 modular UPS system introductionEA660 modular UPS system introduction

Embed Size (px)

Citation preview

EA660 Modular UPS Introduction20KVA 400KVA20KVA-400KVA

1/35

EA660 modular UPS system introductionEA660 modular UPS system introduction

☞ Power range:20-400KVA

☞ Working mode:Intelligent on line (three phases)

☞ Applications :IDC data center,Cl d ti tCloud computing center

☞ Certificate CE

2/35

EA660 modular UPS appearanceEA660 modular UPS appearance

3/35

EA660 modular UPS appearanceEA660 modular UPS appearance

4/35

St t f EA66400Structure of EA66400

Power module can b t 20be up to 20 pcs

5/35

Battery moduleBattery module

H t bl b tt d l thHot swappable battery module , the same

size as the power module ,completely

compatible with the power module drawercompatible with the power module drawer,

without changing the modular cabinet of

UPS system Supporting online hot swapUPS system. Supporting online hot swap,

easy maintenance, redundant battery

module is available , providing highmodule is available , providing high

availability.

6/35

Features of battery moduleFeatures of battery module

The overall design using the same size as power module, power module

slot compatible.

Each battery module equipped with circuit breaker, with short circuit

protection function, more reliability.

Battery module has low voltage& over discharge protection function.

Battery with hot swap design. Simple operation, easy maintenance.

Hot swappable and parallelizability battery module function, providing

higher availability with redundancy battery module.

Internal battery module using high performance free maintenance lead-

acid batteries, with long service life.

Battery module according to the 2 groups of multiple selection, each

b tt d l t i 2 b tt k b tt k t i i 10

7/35

battery module contains 2 battery pack, battery pack containing 10 pcs

12V/ 9AH batteries.

Modular UPS EA660 advantages reliability

Imports components are used internal

Modular UPS EA660 advantages - reliability

Name Model Brand

Imports components are used internal

DSP TMS320F2812 TI

IGBT IKW40N120H3 INFINEON

IGBT IRG4PF50WPBF IR

SCR CLA50E1200HB IXYS

SCR SK100KQ12 SEMIKRON

Fast recovery RHRG75120 IRFast recovery diode RHRG75120 IR

DC relay T92S7D12-12 TYCO Electronics

8/35

Modular UPS EA660 advantages - reliabilityg yWorld-class brands :IC from American TI,IGBT,SCR from Germany INFINEON

Redundancy control

Dual input

system

Decentralized bypasscontrol

9/35Dust netIndependent air-duct design SPD

Modular UPS EA660 advantages reliabilityModular UPS EA660 advantages - reliability

N+X technology for redundancy

Communicating module

LCD screen

gy y

Battery

moduleINTERFACE

(USB,RS232,RS485,SNMP,dry contact)Charging moduleFuse

Mains

UPS Module 1

UPS Module 2

Breaker

Breker

Load

UPS Module 8

Manuall bypass breaker

10/35

Intelligent battery managementg y g

Battery number can be set 32-40 Intelligent three-stage charging

11/35

Battery self-test Battery compensation, management

Intelligent battery management

battery battery

Faulty battery

Easy maintenance-battery number can be set between 16-20 pcs, faulty batteries can be removed

12/35

IGBT rectifier-Green energy high efficiencyIGBT rectifier Green energy, high efficiency

Input power factor> 0.99,IGBT rectifier Input harmonic current < 3%IGBT rectifier

13/35

Voltage

Current

IGBT rectifier waveformInput harmonic current <3%Input power factor:0.99

6-pulse SCR rectified waveformInput harmonic current >30% Input power factor:0.85

12-pulse SCR rectified waveformInput harmonic current >10% Input power factor:0.90

Advantage of high input power factor and low input harmonic current:

1 Less requirement for transformer and generator before the UPS2 Less requirement for input cables and capacity of the breaker3 Decrease the failure rate from the harmonic current

14/35

3 Decrease the failure rate from the harmonic current

Example :

UPS power 200KVA Remark

Example :

UPS power 200KVA Remark

Rectifier structure IGBT SCR

I t f t 0 99 0 85Input power factor 0.99 0.85

Harmonic current 3% 30%

Capacity ratio 1-1.2:1 3:1

Capacity of generator 240KW 600KW

Cummins generator price 31K USD 74K USD 43K USD

can be saved

Breaker capacity 400A 500A ABB brand

Cables 120 square meters 150 square meters

15/35

UPS t ffi i 93%UPS system efficiency >93%

Efficiency

Efficiency compared with traditional low frequency UPS

Modular UPS

Traditional low frequency UPS

Load rate

16/35

Easy expansion by increasing power module

Load power

Load percentage

Load power

L d t

17/35

Load percentage

E i t H t d f ll th d lEasy maintenance-Hot swapped for all the modules

Maintenance can be finished within 1 minutes

All the modules are hot swapped

18/35

E i t S ll i li ht i htEasy maintenance-Small size, light weight

PK200KVA

PK

2000mm 1950mm

modular tower

Weight 510kg 900kg

A 0 6 2 1 04 2

modular tower

1000mm600mm

860mm 1210mm

Area 0.6m2 1.04m2

19/35

Easy maintenance-Big LCD display

LCD+LED+button, friendly interface operations management

Easy maintenance Big LCD display

LCD LED button, friendly interface operations management

LEDLCD

Button

EPO Cold start

Super LCD screen:5.7 inches

High resolution :320 ×240

Intelligent battery monitoring and management

Function setting

10000 Hi t l

20/35

10000 History log

Extensive monitoring interface for different demandsExtensive monitoring interface for different demands

SNMP RS232 RS485 USB Tem compensation Dry contactp y

Remote monitoring can be

available everywhere and every y y

time

21/35

CE tifi tiCE certification

22/35

Modular UPS system configurationDimensions(m WeightName Model Dimensions(m

m)Weight(kg) Configuration

1、Standard configuration is 1 monitoring module,1 charging module;

EA66100 600*1000*1600 225odu e, c a g g odu e;

2、4 modules can be placed;3、Mains input, bypass, output, manual bypass is standard configuration;1 St d d fi ti i 1 it i

System EA66160 600*1000*2000 290

1、Standard configuration is 1 monitoring module,1 charging module;2、8 modules can be placed;3、Mains input, bypass, output, manual 3、 a s pu , bypass, ou pu , a uabypass is standard configuration;

EA66200 600*1000*2000 2801、Standard configuration is 1 monitoring module,1 charging module;2 10 d l b l d2、10 modules can be placed;

EA66400 1200*1000*2000 560

1、Standard configuration is 1 monitoring module,2 charging module;2、20 modules can be placed;2、20 modules can be placed;

Power module

EA66-20PMD 482*590*131 28 Power :20KVA

Charging d l EA66-CM 482*590*131 27 Charging current:30A for each module

23/35

module EA66 CM 482 590 131 27 Charging current:30A for each module

Monitoring module EA66-MM 482*590*131 7

Standard and option configurationStandard and option configurationFunction Explanation Standard Option

C i i RS232、USB、RS485 √Communication port RS232、USB、RS485 √

7 dry contactInverter output、mains input abnormal、overload 、bypass output、system fault、 √7 dry contact overload 、bypass output、system fault、low battery warning、system warning

C class SPD To protect UPS from thunderbolt. 20KA impulse can be protected. √p p

Network monitor SNMP card:internal & external √

Charging module can detect theBattery temperature compensation

Charging module can detect the temperature through the interface, providing temperature compensation

Control the connection between the battery √Battery breaker Control the connection between the battery and the UPS √

Output distributionIncluding 15 breakers,10-32A optional,breaker brand optional(must be selected √

24/35

Output distribution module

breaker brand optional(must be selected the first time purchase,can’t increase the capacity in the future)

Modular UPS specification pPower module:20KVA

Power supply:three phases in three phases out

Input voltage range:204-520Vac, input frequency range:40-70Hz

Input power factor:>0.99, Input harmonic current :<3%

Output power factor:1.0/0.9

Efficiency :>93%

Redundancy parallel:80KVA、160KVA、200KVA can parallel 2 pcs;power more than

200KVA can’t be parallel

Battery number:12V40 pcs(positive and negative,20 pcs for each)32、34、36、38

pcs available;

Ch i t 30A f d l 60A i il bl f 80 200KVA 120A i il blCharging current:30A for one module; 60A is available for 80-200KVA ,120A is available

for that more than 200KVA ;

Low battery alarm point :11VDC*battery number end of discharge:10 2VDC*battery

25/35

Low battery alarm point :11VDC battery number, end of discharge:10.2VDC battery

number

Q&A1. EAST modular UPS static bypass is decentralized controlled, how about the reliability compared with centralized bypass ?

Although centralized bypass control is simple and easy to implement, but single point of

failure can‘t be ignored ,that is why we decide to use decentralized bypass . Currently in

the industry , Eaton, Sakmann, Granville and other modular UPS are all used in a

decentralized bypass technology.

W h t i h d l t k th t d l f lt th thWe have over current in each module, to make sure that once one module fault, the other

can still work.

2 O l h i t li bilit f EAST d l UPS?2. Only one charger is not reliability for EAST modular UPS?

If the charger is dispersed in each power module, once the internal charger is

damaged or short circuit the power module also fails the module does not workdamaged or short circuit, the power module also fails, the module does not work,

with a decline of carrying capacity, which will affect the availability of the entire

system. EAST UPS can use 2 charger for redundancy,200KVA or less can have 2

26/35

chargers, power more than 200KVA can have 4 chargers parallel.

China Telecom cloud computer roomp

27/35

China Telecom cloud computer roomp

28/35

Jordan Communications IDC room

29/35

Fifth People's Liberation Army Hospital,Fifth People s Liberation Army Hospital, modular UPS project in Yinchuan

30/35