11
Fire mitigation pages 6-8 HV JUICE This Issue www.transnet.co.nz Dec 20/Jan 21 Wedge Pressure Earthing PAGE 3 OEL ARC FLASH PROTECTIVE GEAR PAGE 4 RAYSULATE WILDLIFE & ASSET PROTECTION PAGE 8 NEW FAULT INDICATOR PAGE 11

e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

Fire mitigationpages 6-8

HV JUICE

This Issue

ww

w.tr

ansn

et.c

o.n

z

Dec

20

/Jan

21

Wedge Pressure EarthingPAGE 3

OEL ARC FLASH PROTECTIVE GEAR

PAGE 4

RAYSULATE WILDLIFE & ASSET PROTECTION

PAGE 8

NEW FAULT INDICATORPAGE 11

Page 2: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

ERICO Earth Rods have all the benefits of a copper-bonded coating, plus:• Nickel-sealed high strength steel core

• 99.9% pure electrolytic copper coating

• ERICO® name, length, diameter and part number is roll-stamped within 12" (304.8 mm) of chamfered end

• UL logo and control number where applicable stamped on each rod for easy inspection after installation

ERICO's unique manufacturing process includes drawing the steel rod to size before the copper bonding process begins, resulting in a straighter, harder steel core. We use a continuous electro-plating process over the nickel sealed steel core resulting in a permanent molecular bond which will not slip or tear when driven, nor crack when bent, that provides decades of reliable performance.

All ERICO® rods are made to meticulous standards and exceed the requirements outlined in AS/NZS 3000:2007 for minimum surface treatment thickness.

CO

PPER

BO

ND

ED E

ART

H R

OD

S WHAT'S THE POINT?

WHY ERICO?

PLATING PROCESS=

LONGER LIFE

The copper adhesion tests confirm the design feature that prevents the ingress of moisture and subsequently the integrity of the earth rod. ERICO use Carbon steel, grade 1018 which has a much higher tensile strength than the 250 / 350 grade mild steel typical of the core in a tubular copper sheathed earth rod.

COPPER BONDED GROUND RODS

as/nzs 3000:2007compliant to

r

eq uire ment

s

Copper-bonded Nickel Copper-bonded Nickel sealed ERICO rodsealed ERICO rod

Won’t crack when Won’t crack when bentbent

Copper Copper sheathed rodsheathed rodCoating can Coating can crack if bentcrack if bent

ERITECH Earth Rod Testing & Compliance

Australia AS:3000

BritainBS:5514

USAUL467

EuropeEN 50164-2

DIMENSIONS COMPLY COMPLY COMPLY COMPLYCOPPER THICKNESS COMPLY COMPLY COMPLY COMPLYSTRENGTH TEST N/A N/A COMPLY COMPLYCOPPER ADHESION TEST N/A N/A COMPLY COMPLY

BEND TEST N/A N/A COMPLY COMPLY

A grounding system's performance is dependent upon the effective operation of several components. Failure of any one of these renders the entire system ineffective. Electrical elements buried underground are subject to much harsher conditions than their counterparts above ground. The ability of an electrical grounding component to resist corrosion determines its service life.

ERICO COPPER-BONDED COATING:• Permanent molecular bond• Low resistance performance• High fault current capacity

(IEEE® Std 80)• Will not slip or tear when

driven

• Will not crack if rod is bent• Copper coating may vary to meet

required standards• 10 mil (254 micron) minimum

coating on rods listed to UL®467

CARBON STEEL CORE AND TIP*:• Greater Tensile Strength• Deep driving capability *ERICO copper-bonded rods

GROUNDING SYSTEMS:• Protect people• Provide a signal reference for low

voltage digital signals for electronic equipment

• Prevent the flashover of insulators on transmission lines

• Protect expensive equipment, e.g. transformers, capacitors, reclosers, and lightning arrestors

WHY BONDED COPPER?

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 3: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

WRENCH-LOK

WEDGE PRESSURE EARTH CONNECTORS

SHEAR-LOK

Cat No. Connections0-80408-2 25MM² – 13MM ROD/35MM² – 13MM ROD0-83000-1 50MM² – 13MM ROD/70MM² – 13MM ROD

AMP developed the SHEAR-LOK Copper Tap/Grounding Connector for applications in the power utility industry where connectors are required to withstand mid-range magnitudes of fault current (20kV symmetrical RMS).

SHEAR-LOK connectors utilise AMP Wedge Pressure Technology and controlled-torque-drive bolts to provide easily applied and highly reliable ground rod connections. This family of connectors is ideal for MV applications where connections must be made between conductor and rod.

KEY FEATURES

• Wedge Pressure Technology• Shear-head bolt for controlled torque• Removable without conductor damage• No special tools required• Application not inhibited by disfigured ground rod end• Taps into existing ground conductors

Cat No. Connections0-83749-1 35MM² – 13MM ROD/50MM² – 13MM ROD0-83747-3 35MM² – 35MM²/50MM² – 50MM²/50MM² – 70MM²0-83749-2 50MM² – 13MM ROD/70MM² – 13MM ROD0-83748-2 95MM² – 13MM ROD/120MM² – 13MM ROD

The WRENCH-LOK System uses a specially designed shear-head bolt to drive a tapered wedge into the connector body.

All that’s needed to apply it is a common ratchet or socket wrench. When the connection is tightened to the proper torque, the bolt head shears off, giving a positive visual indication of a perfect connection. It’s that simple and sure.

WRENCH-LOK connections can be installed in any weather conditions and are very safe for the installer. This product line offers options to connect conductor to conductor or conductor to ground rod.

WRENCH-LOK meets the requirements of IEEE 837.

KEY FEATURES

• Shear-head bolt for controlled torque• No special tools required• No need to change connector styles,

molds or tooling

• Available in a range of sizes• Cable to Cable, Rod to Rod, & Cable to

Rod connections• 4 sizes cover 35-120mm² connections +UL Listed file # E69905

+UL Listed file # E69905

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 4: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

OEL 40 CAL ARC FLASH PROTECTION

With a 40 Cal Lift Front Switching Hood assembly this kit provides excellent peripheral vision, the light tint lens gives clarity of work environment, and the unit design is lightweight and ergonomically correct for the wearer.

FEATURES• 40 cal/cm² ATPV Rating

• Approximately 60% lighter fabric weight than standard 40 calorie garment

• 2 layers – 5 oz/yd² & 6 oz/yd²- Sewn with Nomex® thread

• 32" long jacket, 32" inseam overalls

• Lightweight 40 Cal hood

• Standard or lift front clear hood options

• Meets current ASTM F1506 and NFPA 70E standards

40 CAL LIFT FRONT HOOD• Extended Peripheral vision

• Permanent Anti Fog Visor

• Highly Transparent Visor

• Lift Front Design

• Lightweight 40 Cal Hood

• 40 cal/cm² ATPV Rating

• Approximately 60% lighter fabric weight than standard 40 calorie garment

• 2 layers – 5 oz/yd² & 6 oz/yd² - Sewn with Nomex® thread

40 CAL PREMIUM JACKET & BIB OVERALLS KIT

CAT No. AFW40LF-NFJB

CAT NO. DESCRIPTION

AFW40-NFJB40 Cal Premium Jacket & Bib Overalls Kit

with Switchgear Hood

AFW40LF-NFJB40 Cal Premium Jacket & Bib Overalls Kit

with Lift Front Hood, Clear

Add suffix for size: -S, -M, -L, -XL, -2XL, -3XL

Advanced Colour Differentiation Technology

Made in the USA

AFW40-NFJB AFW40LF-NFJB

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 5: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

OEL 25 CAL ARC FLASH PROTECTION

FEATURES• 25 cal/cm² ATPV Rating

• Arc flash 32” long jacket and 32”inseam bib overalls

• Relaxed cut for greater mobility

• 25 Cal switchgear hood

• Meets current ASTM F1506 and NFPA70E arc flash Category 3 standards

• Complete with storage bag

• Sizes M-L-XL-2XL-3XL are stock sizes, other sizes available by special order

FEATURES• 25 cal/cm² ATPV Rating

• Arc flash coverall

• Relaxed cut for greater mobility

• 25 Cal switchgear hood

• Meets current ASTM F1506 and NFPA70E arc flash Category 3 standards

• Complete with storage bag

• Sizes M-L-XL-2XL-3XL are stock sizes, other sizes available by special order

25 CAL NAVY JACKET & BIB OVERALLS KIT

25 CAL NAVY COVERALL KIT

CAT NO. DESCRIPTIONAFW25-NFC 25 Cal Coveralls Kit with Switchgear Hood

AFW25-NJB 25 Cal Jacket & Bib Overalls Kit with Switchgear Hood

Add suffix for size: -S, -M, -L, -XL, -2XL, -3XL

POLE TOP RESCUE KIT

This kit provides an ingeniously simple method of rescuing a worker who has fallen from their ladder and is suspended by their lanyard from a cross member.

Simply loop the rope over the cross member, loop it back around itself several times, and clip the carabiner to the worker's harness chest loops.

Once released from their lanyard, they can be lowered gently to the ground thanks to the friction of the rope looped around itself.

KIT CONTENTS

• 23 metre rope with sewn eye & identification label

• Carry bag

Cat No DescriptionPTRK POLE TOP RESCUE KIT 23M

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 6: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

TE CONNECTIVITY FIRE MITIGATION SOLUTIONS

WILDLIFE MANAGEMENTLocalised fires caused by animals such as birds or possums infiltrating your overhead lines and substations are often the result of electrocution. They fall to the ground below and spark a fire. We can help you prevent animal induced wildfires and bushfires with our wide selection of insulating wildlife mitigation solutions, including bushing covers, cross arm guards and more. Each is manufactured from our unique Raychem polymer material. It’s specially formulated to resist tracking, UV degradation and thermal extremes. We are committed to protecting your network for the life of your assets and reducing the risks of wildfire and bushfires with 60+ years of manufacturing and design experience.

VEGETATION MANAGEMENTThe equation is simple. Fuel + Source of Ignition = Fire. Vegetation can act as a fuel to a fire when combined with an ignition source. A vegetation management program is therefore essential to reducing the risk of wildfires and bushfires. We can help you prevent vegetation clashing with conductors and overhead lines while reducing the frequency and expense of trimming and debris removal with reliable safeguards such as overhead line covers and insulators.

GRID HARDENINGAging infrastructure coupled with severe weather can increase the likelihood of bushfires and wildfires. Hardening your grid to make it more resilient and less vulnerable to weather events must be part of any fire mitigation plan. We offer a complete range of insulators and arrestors designed to protect the grids of tomorrow and strengthen them against the volatility of today's changing energy demands. We can help you identify weaknesses and decide upon the most cost-effective measures to strengthen your grid, whether that means underground solutions, conductor replacement or arrestor location and more.

WHEN YOU CAN PREVENT BUSHFIRES BEFORE THEY START

MVLC Line Cover

MVCC Conductor Cover

Bird Guards

Bus Isolation Animal GuardBushing CoversHigh Voltage Busbar TapeBus Connection Insulating Covers

The strategic installation of insulating components and barriers can be used to minimise the impact of wildlife on power grid assets. If these components are specified correctly, such modifications can minimise costly power outages while reducing fire risk and safeguarding assets and the environment for 40 years or more.

Fire-related outages caused by wildlife and vegetation generally fall into two categories:

• Phase-to-earth faults. These occur when wildlife or debris forms a conductive pathway connecting the equipment phase to the ground

• Phase-to-phase faults. These occur when two adjacent phases collide or are momentarily connected via wildlife or debris, producing hot, molten metal particles

THE COST OF FIRESImproved fire safety and operating reliability helps utility owners avoid the catastrophic implications of wildlife-related fires, including:

• Injuries and loss of life

• Damage to (and loss of) power grid assets

• Service interruptions and power outages

• Environmental hazards and danger to personnel

• Damage to agricultural and horticultural assets

• Regulatory penalties and litigation

• Reputational damage and damage to shareholder value

For most utilities, the ability to avoid even one potential outage can help to underwrite the costs to upgrade the system with appropriate protections.

Trust TE's proven track record of experience in the field, broad expertise in electrical and mechanical component design, fully integrated compounding, supply-chain integration, testing and installation, and materials science expertise.

CONSIDERATIONS FOR ASSET PROTECTIONIt is essential to select polymeric formulations that can withstand the harsh operating conditions most overhead lines and substations routinely experience — including high-voltage stress, pollution buildup, pollution induced arcing, flashover, elevated temperatures and mechanical stress. The three most critical material science performance attributes to consider when specifying AP components are these:

• Tracking and erosion resistance (TERT)

• Ultraviolet (UV) resistance

• Thermal endurance

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected] Specials and Products featured in TRANSNET JUICE are avai lable from al l good electr ical wholesalers .

Page 7: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

RAYCHEM RAYSULATE• Customised solutions for all substation

applications• Vacuum formed in New Zealand to fit

individual requirements• Raysulate HVIS is compatible with all

other products in the Raychem MV insulation enhancement system enabling all problematic areas to be covered using a combination of standard and custom formed products

• Excellent tracking & erosion resistant properties

• Manufactured from a non-halogen based material, noxious and corrosive effects are greatly reduced in the event of a fire

• Excellent UV and weather resistant properties make Raysulate products suitable for indoor and outdoor use

• Can be stored indefinitely at temperatures up to 50°C without loss of performance

• Easy to install on site

CUSTOM SOLUTIONS• We work with your engineers to

determine what is required• From your drawings we have custom

forms made to exacting dimensions• We can assist with installation training • All custom Raysulate solutions are

produced in New Zealand

RAYSULATE - TE WILDLIFE & ASSET PROTECTION

“Damage to electrical substations could be eliminated and a reduction in outages achieved by proactively applying TE’s Wildlife & Asset Protection products.”

“TE estimates that damage to electrical substations could be reduced by as much

as 80% simply by applying insulation”.

Wildlife infiltrating substations and causing flashovers is a constant problem for asset owners. A quick, easy, and reliable solution is the extensive Raychem range of asset protection products, including standard and custom formed products. Talk to your local rep about what might be available for your unique application. We have capacity to design and manufacture custom solutions right here in New Zealand from trusted Raychem Raysulate products.

Raysulate Vacuum Forming Plant

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 8: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

UPGRADE YOUR INSULATED TOOLKIT

Precision ground cutting blades for clean and smooth cuts. Single handed operation with little hand force required due to a high transmission ratio and 2-stage ratchet drive mechanism. 1000V VDE IEC/EN 60900.

FEATURES

• 1000V VDE dual component handles• Black lacquered head

200000cable stripping knife

KP9536280insulated ratchet cable cutter

irw13/171000V VDE Insulated Ratchet Wrench

101999/Z11000V VDE Screwdriver set

FEATURES

• 1000V VDE rated• Comfort grip handle• 50mm rigid straight blade• Protective blade cover included

FEATURES

• Injected blade profile on top of handle for fast access in tool pouch and tool box

• Magnetic blades made from molybdenum-vanadium steel

Description Length (mm)1000V VDE CABLE STRIPPING KNIFE 150

Description Type6PC 1000V VDE SET WITH SQ 1, 2,

POZI 1, 2, AND 3.5MM, 6.5MM SLOTTED

Cat No. Description

IRW13/17 INSULATED RATCHET SPANNER 13 & 17MM SOCKETS

Cat No. Capacity Length (mm)

KP953628052MM DIA

380MM², COPPER AND ALI CUTTING

ONLY 750MCM280

• For use with all shear bolt connectors (IPCs and Fuse Carriers)

• 13mm and 17mm A/F sockets in one spanner• Reversible ratchet• Fits stainless steel nuts used in strain and

suspension clamps• Fixed sockets that can not be lost or

dropped during installation• 1000V insulated for added user safety• 6 sided hex sockets protect integrity of

plastic bolt heads

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 9: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

EUREKA ARC FLASH PROTECTION

ARC FLASH INTENSITYThe expected intensity of an arc flash incident can be calculated by engineers who have access to the properties of their electric installations. It is not always that the highest voltage is the most dangerous!

BODY PARTS MOST AT RISK1. HandsAre by far the most exposed body part and suffer the highest number of injuries

2. FaceAfter hands, the face is the second most exposed!

3. BodyAlthough the body can take more damage and is usually more protected, the risk of dying increases drastically if 70% or more of the skin is burntSeverity of injury reduces by the square of the distance. Double the distance from the explosion equals four times less energy

Cat No. Description13-4HFR FLAME RESISTANT ARC FLASH GLOVESUse suffix for size: -XS, -S, -M, -L, -XL, -2XL

FEATURES• Flame resistant• Optimized for medium Arc

Flash risks• Improved Dexterity• Perfect in tough working

conditions with high spark, heat and flame risks

• High performance in cut resistance

• Cat II• Arc Flash ASTM F2675, ATPV

= 30 cal/cm² palm, 5.8 Cal/cm² back of hand

EUREKA 13-4HFR ARC RATED WORK GLOVES

ARC FLASH ASTM F2675, ATPV= 30 Cal/cm² (Palm) 5.8 Cal/cm² (Back of Hand)TECHNICAL PROPERTIES

Abrasion

Cut

Tear

Puncture

Impact

Needle

Heat

Water & oil resistance

Grip

Breathing

0 8000 cycles

Dry

Low

75 N

150 N

10 N

150 N

High

Wet/Oil

Arc Flash 60 Cal/cm2

A5

Contact

0

Flame resistance

0

0

0

0

Low

A1 A2 A3 A4 A6 A7 A8 A9

A B C D E F

ANSIEN388

High

F F FA: ABRASION (1-4)B: CUT (1-5)C: TEAR (1-4)D: PUNCTURE (1-4)F: ISO CUT (A-F)P: IMPACT PROTECTION

ISO Cut force (A-F)A | > 2 NB | ≥ 5 NC | ≥ 10 ND | ≥ 15 NE | > 22 NF | > 30 N

EN388

C AT I I

ARC FLASH ASTM F2675, ATPV=30 Cal/cm2 (Palm)5,8 Cal/cm2 (Back of Hand)

ANSI CUTLEVEL

A5

XS

Print = 23 Cal/cm2

7S

8M

9L

10XL

11

13-4 Heat FR

FLAME RESISTANT - DEXTERITY - ARC FLASH

41324X

EN407

3543E

XXL

ART.NO: 13-4HFR60 pairs (5 dozen)/Carton

A: BURNING BEHAVIOUR (1-4)B: CONTACT HEAT (1-4)C: CONVECTIVE HEAT (1-4)D: RADIANT HEAT (1-4)E: SMALL SPLASHES OF MOLTEN METAL (1-4)F: LARGE QUANTITIES OF MOLTEN METAL (1-4)

12

TECHNICAL PROPERTIES

Abrasion

Cut

Tear

Puncture

Impact

Needle

Heat

Water & oil resistance

Grip

Breathing

0 8000 cycles

Dry

Low

75 N

150 N

10 N

150 N

High

Wet/Oil

Arc Flash 60 Cal/cm2

A5

Contact

0

Flame resistance

0

0

0

0

Low

A1 A2 A3 A4 A6 A7 A8 A9

A B C D E F

ANSIEN388

High

F F FA: ABRASION (1-4)B: CUT (1-5)C: TEAR (1-4)D: PUNCTURE (1-4)F: ISO CUT (A-F)P: IMPACT PROTECTION

ISO Cut force (A-F)A | > 2 NB | ≥ 5 NC | ≥ 10 ND | ≥ 15 NE | > 22 NF | > 30 N

EN388

C AT I I

ARC FLASH ASTM F2675, ATPV=30 Cal/cm2 (Palm)5,8 Cal/cm2 (Back of Hand)

ANSI CUTLEVEL

A5

XS

Print = 23 Cal/cm2

7S

8M

9L

10XL

11

13-4 Heat FR

FLAME RESISTANT - DEXTERITY - ARC FLASH

41324X

EN407

3543E

XXL

ART.NO: 13-4HFR60 pairs (5 dozen)/Carton

A: BURNING BEHAVIOUR (1-4)B: CONTACT HEAT (1-4)C: CONVECTIVE HEAT (1-4)D: RADIANT HEAT (1-4)E: SMALL SPLASHES OF MOLTEN METAL (1-4)F: LARGE QUANTITIES OF MOLTEN METAL (1-4)

12

TECHNICAL PROPERTIES

Abrasion

Cut

Tear

Puncture

Impact

Needle

Heat

Water & oil resistance

Grip

Breathing

0 8000 cycles

Dry

Low

75 N

150 N

10 N

150 N

High

Wet/Oil

Arc Flash 60 Cal/cm2

A5

Contact

0

Flame resistance

0

0

0

0

Low

A1 A2 A3 A4 A6 A7 A8 A9

A B C D E F

ANSIEN388

High

F F FA: ABRASION (1-4)B: CUT (1-5)C: TEAR (1-4)D: PUNCTURE (1-4)F: ISO CUT (A-F)P: IMPACT PROTECTION

ISO Cut force (A-F)A | > 2 NB | ≥ 5 NC | ≥ 10 ND | ≥ 15 NE | > 22 NF | > 30 N

EN388

C AT I I

ARC FLASH ASTM F2675, ATPV=30 Cal/cm2 (Palm)5,8 Cal/cm2 (Back of Hand)

ANSI CUTLEVEL

A5

XS

Print = 23 Cal/cm2

7S

8M

9L

10XL

11

13-4 Heat FR

FLAME RESISTANT - DEXTERITY - ARC FLASH

41324X

EN407

3543E

XXL

ART.NO: 13-4HFR60 pairs (5 dozen)/Carton

A: BURNING BEHAVIOUR (1-4)B: CONTACT HEAT (1-4)C: CONVECTIVE HEAT (1-4)D: RADIANT HEAT (1-4)E: SMALL SPLASHES OF MOLTEN METAL (1-4)F: LARGE QUANTITIES OF MOLTEN METAL (1-4)

12

5.8-30

• Actual fabric thickness of 0.8-0.9mm corresponds to certificate AND real gloves!

INTERMEDIATE AREAPartially protected by the ablative

effect of the print and coating. Protection estimated between 10-

15cal/cm²

COATINGProvides additional protection

ATPV 30 cal/cm²

DURABLE SPECIAL PRINTHighest protection through ablative

effect and reflection of radiation ATPV 23 cal/cm²

ATPV PROTECTION AREAS EXPLAINED

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 10: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

GET ADVANCED FAULT DETECTION

Fault Indicator for Overhead LinesThe FLA3.1VL is a robust and versatile Fault Passage Indicator (FPI) with the unique ability to query and set parameters via remote control from the ground. The FLA3.1VL has a 360deg bright flashing LED to indicate fault passage with a myriad of fault detection and threshold settings. The FLA3.1VL is hot-stick mountable with a simple hot-stick adapter and can accommodate a wide conductor range.

Using the FIS-FR (Relay/Dry-contact) or FIS-FS (Modbus/Serial) gateways, you can connect the FLA3.1VL radio interface to SCADA. The FLA3.1VL can be queried for line current, temperature, battery status and presence of voltage among other parameters.

Features• Easy and full configurability with remote control• Trip current fixed threshold (between 10-800A in 10A steps)

OR

Automatic trip current threshold depending on service current

• Trip current di/dt: di selectable between 5 and 100A

dt: 20ms at 50Hz

• Response delay selectable between 40ms and 300ms• Ultra-bright red LED indication 360deg visible.• Test function by remote control including battery status.• Replaceable Lithium type A 3.6V battery. 800hrs flashing life• Reset function:

– Manual by remote control – Time selectable from 30min to 12h – Automatic by recovering network current or voltage.

• Capability of connecting to SCADA systems via remote indication interfaces type RIS-FR and RIS-FS.

• Detection and indication of – Permanent fault – Temporary faults – Transient currents

• German made and built to last!

Advanced Fault DetectionThe FLA3.1VL fault passage indicator provides two methods to detect faults. The absolute threshold detection method works with a selected fixed current – selectable in 10A increments; or an automatically calculated absolute threshold. This method can be disabled when not required. Additionally, the fault indicator provides a di/dt measurement method. This method responds to current load changes within a certain period of time. The level of lead change can be adjusted via the remote control. Additionally, a subsequent voltage loss is used as a criterion to assure correct detection of faults. All parameters can be set and confirmed via the Remote Control.

NEW PRODUCT

Full Specifications

www.transnet.co.nzPh 0800 442 182 +64 9 274 3340

[email protected]

Page 11: e gation Juice...BS:5514 USA UL467 Europe EN 50164-2 DIMENSIONS COMPLY COMPLY COMPLY COMPLY COPPER THICKNESS COMPLY COMPLY COMPLY COMPLY STRENGTH TEST N/A …

Sustainability, Innovation & InSustainability, Innovation & Inxxx

Poly-View System™ Technology | Clear Polymer IR Window Optic Versatile & Durable | Impact-Resistant | Guaranteed Against Transmission Loss

MaterialsWINDOW HOUSING & COVER

UL 94 5VA NYLON (SWITCHGEAR-GRADE PLASTIC); -40°C (-40°F) TO 273°C (523°F);

EASY-GRIP™ STAINLESS STEEL COVER

OPTICUL 746 COMPLIANT, VISUAL, UV AND IR

TRANSMISSIVE POLYMER; -40°C (-40°F) TO 325°C (617°F)

REINFORCING GRILL

ALUMINIUM COATED WITH UL 94 5VA NYLON; -40°C (-40°F) TO 273°C (523°F)

GASKETS UL 94 5VA TPE; -40°C (-40°F) TO 273°C (523°F)

HARDWARE 316 STAINLESS STEEL

OtherUSEFUL TEMPERATURE RATING -40°C (-40°F) TO 200°C (392°F)

WATER & DUST INGRESS IP65/NEMA 4: CLOSED & WHEN IN USE

Dimensions

Model Body Diameter

Window Diameter

Assembly Thickness

VPT-50 9.1 CM 5.1 CM 2.6 CM

VPT-75 12.1 CM 7.6 CM 2.6 CM

VPT-100 15.1 CM 10.2 CM 2.6 CM

Note: The dimensions listed above are not installation dimensions. Do NOT cut prior to receiving your IRISS window and installation template.

FEATURES• Protected by an Unconditional Lifetime

Warranty

• Stress Free Viewing – The polymer-based infrared window maintains fixed and stable transmission (FAST) for life unlike crystal based infrared windows

• Arc Containment Tested – Successfully tested to the IEC 62271-200 standard for arc containment on metal enclosed switchgear assemblies

• Durable and Rugged – Polymer-based IR windows resist mechanical stresses applied to IR windows better than crystal-based IR windows

• Any Camera, Any Task – The exclusive industrial-grade, reinforced polymer optic will work with all ranges of Infrared, Ultraviolet and Visual Inspection Cameras

• Proudly Made in the United States of America

• Anti-Fogging Optic – Polymer optics don not experience a temperature differential across the optic like crystal optics do

• Environmentally Sealed Design – Seamless custom gaskets ensure the NEMA 4 / IP 65 ingress protection rating is maintained

• Three sizes available in the VPT range

CERTIFICATIONS• IEEE C37 20.7 Type 2B, C37 20.2.a.3.6: Impact

and Load• IEC 62271-200, 60262271-200, 60298 Appendix

A, 60068-2-6:2007, 60068-2-3, 62268-2-78:2012• IP 65 / NEMA 4

POLY-VIEW™ OPTICS SYSTEMOur exclusive Poly-View™ technology enables visual as well as traditional IR inspections across the entire Infrared spectrum. Ultraviolet (UV) inspection can also be performed via the Poly-View™ system.

VPT SERIES INFRARED WINDOWSThe world’s only clear polymer IR window optic

Poly-View System™ Technology | Clear Polymer IR Window Optic | Versatile & Durable | Impact-Resistant | Guaranteed Against Transmission Loss

Placeholder, not for PrintingLogo use must be

approved

Min Size 17mm Height

Cxxxxxx

TransNet NZ Ltd has made every reasonable effort to ensure the accuracy of this information and it is to the best of our knowledge correct and reliable. Under no circumstances does this constitute an assurance of any particular quality or performance and users should independently evaluate the suitability of products for their desired application. All information in this publication including pricing, drawings, illustrations, images and graphic designs are reflections of our current understanding. TransNet NZ Ltd reserves the right to make any adjustment to this information at any time. Our liability for the products outlined in this publication is set forth in our standard terms and conditions of trade. In case of any potential ambiguities or questions, please contact us for clarification.

With IRISS VPT Infrared Windows

TAKE A GOOD LOOK

Auckland78 Cryers RoadEast TamakiAucklandNEW ZEALAND Ph 0800 442 182 Fax 0800 442 183PO Box 39 383 Howick, Auckland

Wellington10 Petone AvePetoneWellingtonNEW ZEALAND Ph 04 576 2530Fax 04 576 0040PO Box 39 383 Howick, Auckland

NEW ZEALAND

[email protected]

TransNet TongaNuku'alofaLakalakaimonu Multi Utility ComplexTaufa'ahau RoadPoutahaNuku'alofaTONGA Ph +67 627 939Fax +67 627 976 PO Box 2932Nuku'alofa

TONGA

[email protected]