PVC INSULATED, SINGLE CORE FLEXIBLE CABLES
CODE StandardsHO5V-K, HO7V-K CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004CU: IEC 60228 CLASS 5K: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed in control panels and electrical 1. Flexible wires with fine stranded copperequipments of mobile devices, on and under conductors.plaster as laid in conduit. 2. PVC insulation.
mm² kg/km A A1,5 19,39 15 24
2,50 29,58 20 324,00 43,99 25 426,00 62,57 33 54
10,00 107,00 45 7316,00 163,35 61 9825,00 253,38 80 12935,00 341,59 103 15850,00 494,70 120 19870,00 680,95 152 24595,00 936,73 184 292
120,00 1.180,30 212 344150,00 1.530,62 415 391185,00 1.799,94 485 448240,00 2.416,92 600 528300,00 2.980,00 - 618
H07V
-K H07V-K www.remaskablo.com
www.remaskablo.com [email protected]
26,2
4,6
0,206
0,1060,08010,0641
12,37,98
28,6
4,03,52,9
1,21
4,953,3
1,91
0,1610,129
0,780,5540,3860,272
18,721,022,7
6,17,39,2
14,416,5
10,312,5
Current Carrying Capacity
ohm / kmmm
Type
OverallDiameter(approx.)
Nominalcross-section
NetWeight
(approx.)
DC Resistanceat Conductor 20 °C In ground
at 20 °C In Air
at 30 °C
PVC INSULATED, MULTI-CORE FLEXIBLE CABLES
CODE StandardsH05VV-F CU/PVC/PVC TS EN 50525-2-11, VDE 0281-5-IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V
Application ConstructionUsed on houshold appliances in covered, 1. Flexible wires with fine stranded copperdry, steamed and humid places where conductorslow mechanical stress exists. 2. PVC insulation.
3. PVC sheath
mm² mm kg/km2 x 0,75 6,1 52,43
2 x 1 6,4 61,002 x 1,5 7,3 80,732 x 2,5 8,9 121,582 x 4 10,3 170,69
3 x 0,75 6,5 62,153 x 1 6,9 73,81
3 x 1,5 8,0 102,793 x 2,5 9,7 150,343 x 4 11,2 216,53
4 x 0,75 7,0 74,044 x 1 7,8 94,21
4 x 1,5 8,9 126,384 x 2,5 10,6 191,304 x 4 12,2 263,44
5 x 0,75 8,0 98,625 x 1 8,4 111,53
5 x 1,5 10,1 158,895 x 2,5 11,8 229,465 x 4 13,7 328,29
H05VV-F www.remaskablo.com
www.remaskablo.com [email protected]
Current Carrying Capacity
ohm / km A
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
H05V
V-F
26,00 619,50 10
3226,00 619,50
13,30 167,98 254,95
4,95 32
4,95 3226,00 619,50 1013,30 167,98 20
In Airat 30 °C
13,30 167,98 20
1013,30 16
19,50
7,98 254,95 32
1026,00 6
H07V-R www.remaskablo.com PVC İZOLELİ TEK DAMARLI KABLOLAR KOD Standartlar HO5V-U, HO7V-U, HO7V-R CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004 CU: IEC 60228 SINIF 1 & 2 R: Çok Telli (örgülü rijit) iletken Teknik Veriler Maksimum çalışma sıcaklığı : 70 °C Maksimum kısa devre sıcaklığı : 160 °C (max. 5 sn.) Anma gerilimi : 300/500 V- 450/750 V Kullanıldığı Yerler Yapısı Kapalı, kuru yerlerde, sabit tesislerde, dağıtım 1.Tek veya çok telli bakır iletken. panolarında, sıva altı ve sıva üstünde boru içinde 2. PVC izole ve üzerinde kullanılır. Tip Nominal Kesit Dış Çap (Yaklaşık.) Net Ağırlık (Yaklaşık.) İletken DC Direnci 20 °C’de max. DC Akım Taşıma Kapasitesi Toprakta 20 °C’de Havada 30 °C’de mm² mm kg/km ohm / km A AH07V-R 10,00 5,9 108,42 1,830 45 73 16,00 6,9 167,71 1,150 61 98 25,00 8,3 256,84 0,727 83 129 35,00 9,7 356,09 0,524 103 158 50,00 11,3 481,05 0,387 132 198 70,00 12,8 694,00 0,268 165 245 95,00 14,6 938,00 0,193 197 292 120,00 16,2 1.172,00 0,153 235 344 www.remaskablo.com [email protected]
PVC INSULATED, PVC SHEATED MULTI-CORE FLEXIBLE CABLES
CODE StandardsH07VVH6-F CU/PVC/PVC TS IEC 60502CU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed in cable ducts and 1. Flexible wires with fine stranded copperunder ground where low conductorsmechanical stress exists. 2. PVC insulation.
3. PVC filler4. PVC sheath
mm² mm kg/km1 x 1,5 5,1 35,001 x 2,5 6,8 59,001 x 4 7,9 98,001 x 6 8,8 170,67
1 x 10 9,8 218,921 x 16 10,9 283,941 x 25 12,5 372,791 x 35 13,6 469,291 x 50 15,5 624,851 x 70 17,5 821,641 x 95 19,0 1.049,05
1 x 120 21,3 1.296,511 x 150 22,8 1.574,921 x 185 24,6 1.885,831 x 240 27,5 2.431,641 x 300 32,6 3.450,002 x 1,5 8,1 105,582 x 2,5 9,7 150,992 x 4 10,9 198,922 x 6 14,5 340,74
2 x 10 16,8 487,962 x 16 19,0 665,842 x 25 22,2 924,972 x 35 24,5 1.185,43
7,98 20
NYY-
FLEX
NYY
-FLE
X
456180
0,3860,2720,206 184
212315
-
-16202533
12,37,984,953,3
1,91
0,0641
16
2533456180
103120152
0,780,554 103
12,3
4,953,3
1,911,21
0,161
1,21
NYY-FLEX (YVV-K) www.remaskablo.com
Current Carrying Capacity
ohm / km A
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C In Air
at 30 °C
0,1290,106
0,0801 -
0,780,554
2 x 50 28,8 1.665,542 x 70 33,4 2.273,732 x 95 37,0 2.927,93
2 x 120 42,0 3.711,432 x 150 47,0 4.180,003 x 1,5 8,7 127,553 x 2,5 10,5 184,443 x 4 11,8 246,633 x 6 15,3 405,62
3 x 10 17,7 591,013 x 16 20,1 819,843 x 25 23,6 1.145,413 x 35 26,1 1.484,763 x 50 30,8 2.099,713 x 70 35,8 2.881,214 x 1,5 9,7 156,694 x 2,5 11,3 220,374 x 4 12,8 301,904 x 6 16,6 494,13
4 x 10 19,3 726,894 x 16 21,9 1.018,584 x 25 25,8 1.431,024 x 35 28,8 1.879,834 x 50 33,9 2.650,955 x 1,5 10,7 189,495 x 2,5 12,6 271,615 x 4 14,4 375,425 x 6 18,0 589,42
5 x 10 20,9 872,225 x 16 23,9 1.230,335 x 25 28,3 1.742,485 x 35 31,7 2.301,935 x 50 37,4 3.255,73
3 x 16+10 21,3 943,763 x 25+16 24,8 1.323,943 x 35+16 26,9 1.642,643 x 50+25 32,1 2.345,353 x 70+35 37,5 3.243,50
NYY
-FLE
X
N
YY-F
LEX
6180
103120152
456180
103120
16202533
152184212315
61
7,984,95
152
6180
0,3860,272
120
103120
16
3345
16
0,3860,272
0,780,5540,386
0,5540,386
1,21 / 1,910,78 / 1,21
0,554 / 1,21
12,3
1,91
0,78
www.remaskablo.com [email protected]
3,3
1,210,78
0,554
80103120
7,984,953,3
1,911,21
0,272 / 0,554
12,3
20253345
2025
0,386 / 0,78
1,21
12,37,984,953,3
1,91
0,2060,1610,129
PVC INSULATED, PVC SHEATED MULTI-CORE FLEXIBLE CABLES
CODE StandardsH07VVH6-F CU/PVC/PVC TS IEC 60227-6CU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed in cable ducts and 1. Flexible wires with fine stranded copperunder ground where low conductorsmechanical stress exists. 2. PVC insulation.
3. PVC filler4. PVC sheath
mm² mm kg/km2 x 1,5 8,1 105,582 x 2,5 9,7 150,992 x 4 10,9 198,922 x 6 14,5 340,74
2 x 10 16,8 487,962 x 16 19,0 665,842 x 25 22,2 924,972 x 35 24,5 1.185,432 x 50 28,8 1.665,542 x 70 33,4 2.273,732 x 95 37,0 2.927,93
2 x 120 42,0 3.711,432 x 150 47,0 4.180,003 x 1,5 8,7 127,553 x 2,5 10,5 184,443 x 4 11,8 246,633 x 6 15,3 405,62
3 x 10 17,7 591,013 x 16 20,1 819,843 x 25 23,6 1.145,413 x 35 26,1 1.484,763 x 50 30,8 2.099,713 x 70 35,8 2.881,214 x 1,5 9,7 156,69
H07V
V-F
H
07VV
-F
13,3
1,210,78
0,5540,3860,272
13,37,984,953,3
45
16
25
13,37,984,953,3
1,91
315
184
120
80
33
20
212
152
103
61
1,91
0,206
H07VV-F www.remaskablo.com
In Airat 30 °C
6180
103120
16152
Current Carrying Capacity
0,161
253345
ohm / km A
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
1620
0,129
1,210,78
0,5540,3860,272
4 x 2,5 11,3 220,374 x 4 12,8 301,904 x 6 16,6 494,13
4 x 10 19,3 726,894 x 16 21,9 1.018,584 x 25 25,8 1.431,024 x 35 28,8 1.879,834 x 50 33,9 2.650,955 x 1,5 10,7 189,495 x 2,5 12,6 271,615 x 4 14,4 375,425 x 6 18,0 589,42
5 x 10 20,9 872,225 x 16 23,9 1.230,335 x 25 28,3 1.742,485 x 35 31,7 2.301,935 x 50 37,4 3.255,73
3 x 16+10 21,3 943,763 x 25+16 24,8 1.323,943 x 35+16 26,9 1.642,643 x 50+25 32,1 2.345,353 x 70+35 37,5 3.243,50
0,386 / 0,780,272 / 0,554
H07V
V-F
H0
7VV-
F
1,210,78
0,5540,386
1,21 / 1,91
7,984,953,3
1,91
80
120
0,78 / 1,210,554 / 1,21
33456180
103
2025
120
www.remaskablo.com [email protected]
1,210,78
0,38613,3
0,554
7,984,953,3
1,91
152
103
61
103
61
33
2016
25
45
80
120
FLAT LIFT CABLES
CODE StandardsH05VVH6-F CU/PVC/PVC EN 50214CU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V
Application ConstructionUsed as control cables in elevators, 1.Flexible wires with fine stranded copperescalators, cranes and conveyor systems. conductors
2.PVC insulation with number printed3.PVC sheath
mm² mm ohm / km3 x 0,75 4,10 x 9,90 26,00
3 x 1 4,20 x 10,20 19,503 x 1,5 5,10 x 11,90 13,303 x 2,5 5,73 x 14,39 7,983 x 4 6,64 x 15,93 4,95
4 x 0,75 4,10 x 12,20 26,004 x 1 4,20 x 12,60 19,50
4 x 1,5 5,10 x 14,81 13,304 x 2,5 5,73 x 17,92 7,984 x 4 6,64 x 19,98 4,954 x 6 7,16 x 22,04 3,30
4 x 10 8,89 x 27,37 1,914 x 16 10,20 x 32,20 1,214 x 25 12,00 x 38,60 0,78
5 x 0,75 4,10 x 14,50 26,005 x 1 4,20 x 15,00 19,50
5 x 1,5 5,10 x 17,71 13,305 x 2,5 5,73 x 21,45 7,985 x 4 6,64 x 23,99 4,955 x 6 7,16 x 26,60 3,30
5 x 10 8,89 x 33,27 1,915 x 16 10,20 x 39,20 1,215 x 25 12,00 x 47,20 0,78
10
H05VVH6-F www.remaskablo.com
Type Nominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
H05V
VH6-
F
H05V
VH6-
F
Akg/km80,0088,00
95,00109,00
119,70135,20
Current Carrying CapacityIn Air
at 30 °C
278,88
485,17
1.129,50
610
610
6
32
32
1625
25
45
125,00
243,00
313,50
639,50
1.316,70919,80
405,80
225,00
174,00
381,50
192,40
16153,00
6488
16
32
64
11588
45
25
115
1.620,50
789,90
6 x 0,75 4,10 x 16,70 26,006 x 1 4,24 x 17,73 19,50
6 x 1,5 5,10 x 21,61 13,306 x 2,5 5,73 x 26,48 7,986 x 4 6,64 x 29,57 4,95
9 x 0,75 4,10 x 24,10 26,009 x 1 4,24 x 25,55 19,50
9 x 1,5 5,10 x 31,31 13,309 x 2,5 5,73 x 38,57 7,989 x 4 6,64 x 43,20 4,95
12 x 0,75 4,10 x 31,00 26,0012 x 1 4,20 x 33,00 19,50
12 x 1,5 5,10 x 40,05 13,3012 x 2,5 5,73 x 49,16 7,9812 x 4 6,64 x 55,33 4,95
16 x 0,75 4,10 x 40,47 26,0016 x 1 4,20 x 43,10 19,50
16 x 1,5 5,10 x 52,62 13,3016 x 2,5 5,73 x 64,78 7,9816 x 4 6,64 x 73,01 4,95
18 x 0,75 4,10 x 45,01 26,0018 x 1 4,20 x 48,10 19,50
18 x 1,5 5,10 x 58,33 13,3018 x 2,5 5,73 x 71,84 7,9818 x 4 6,64 x 81,1 4,95
20 x 0,75 4,10 x 50,16 26,0020 x 1 4,20 x 53,38 19,50
20 x 1,5 5,15 x 65,23 13,3020 x 2,5 5,73 x 80,40 7,9820 x 4 6,64 x 90,69 4,95
24 x 0,75 4,10 x 59,65 26,0024 x 1 4,20 x 63,64 19,50
24 x 1,5 5,10 x 77,83 13,3024 x 2,5 5,73 x 95,99 7,9824 x 4 6,64 x 108,64 4,95
www.remaskablo.com [email protected]
6
6
6
6
10
10
10
10
474,19
10
10
6
6
6
382,14
368,00422,23
406,54
2516
32
864,18
H05V
VH6-
F
H05V
VH6-
F135,00
479,52
154,00
194,00224,00
245,00289,00
328,17
817,67
1.698,00
824,37
1.013,00
1.274,40
622,16
557,64 10
229,80
455,00
475,40
425,80
1.216,00
1.432,00
683,00
908,19
1.133,19
552,54
616,79
664,18
325,40
32
16
25
32
1625
16
32
25
32
16
25
32
1625
16
32
25
330,50
PVC SHEATED FLAT LIFT AND SUBMERSIBLE PUMP CABLES
CODE StandardsH07VVH6-F CU/PVC/PVC TS IEC 60227-6 71FCU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed as control and power cables 1. Flexible wires with fine stranded copperin elevators, escalators, cranes conductorsand submersible pumps. 2. PVC insulation.
3. PVC sheath
mm² mm kg/km2 x 1,5 6,10 x 9,00 98,312 x 2,5 7,33 x 10,86 147,822 x 4 7,84 x 11,89 187,752 x 6 8,36 x 12,92 234,77
2 x 10 9,69 x 15,59 355,192 x 16 11,20 x 18,20 511,082 x 25 12,80 x 21,40 706,852 x 35 14,35 x 24,10 937,752 x 50 16,40 x 28,00 1.293,222 x 70 18,60 x 32,20 1.742,572 x 95 21,20 x 36,30 2.326,04
2 x 120 24,00 x 41,40 2.941,122 x 150 25,90 x 44,80 3.593,763 x 1,5 6,10 x 11,90 134,013 x 2,5 7,33 x 14,39 202,223 x 4 7,84 x 15,93 260,703 x 6 8,36 x 17,48 329,83
3 x 10 9,69 x 21,48 506,813 x 16 11,20 x 25,20 733,183 x 25 12,80 x 30,00 1.021,973 x 35 14,35 x 33,85 1.359,303 x 50 16,40 x 36,90 1.883,203 x 70 18,60 x 45,80 2.546,73
H07VHH6-F www.remaskablo.com
Type DC Conductor
Resistance at 20 °C
NetWeight
(approx.)
OverallDiameter(approx.)
Nominalcross-section
ohm / km
Current Carrying Capacity
A
H07V
VH6-
F
H
07VV
H6-F
202533456180
7,98
0,129
0,206
0,386
0,78
1,91
4,95
7,9813,3
1,21
3,3
0,781,211,913,3
4,95
0,2720,3860,554
315
184
120
80
45
103120152
16
In Airat 30 °C
13,3
25
16
212
152
103
61
33
20
0,161
0,272
0,554
3 x 95 21,20 x 51,40 3.394,893 x 120 24,00 x 58,80 4.295,913 x 150 25,90 x 63,70 5.257,834 x 1,5 6,10 x 14,81 169,714 x 2,5 7,33 x 17,92 256,634 x 4 7,84 x 19,98 333,664 x 6 8,36 x 22,04 424,88
4 x 10 9,69 x 27,37 658,444 x 16 11,20 x 32,20 955,284 x 25 12,80 x 38,60 1.337,094 x 35 14,35 x 43,60 1.780,864 x 50 16,40 x 51,20 2.473,174 x 70 18,60 x 59,40 3.350,894 x 95 21,20 x 66,50 4.463,75
4 x 120 24,00 x 76,20 5.650,705 x 1,5 6,10 x 17,71 205,405 x 2,5 7,33 x 21,45 311,035 x 4 7,84 x 24,02 406,625 x 6 8,36 x 26,60 519,94
5 x 10 9,69 x 33,27 810,065 x 16 11,20 x 39,20 1.177,385 x 25 12,80 x 47,20 1.652,215 x 35 14,35 x 53,35 2.202,415 x 50 16,40 x 62,80 3.063,155 x 70 18,60 x 73,00 4.155,065 x 95 21,20 x 81,60 5.532,60
5 x 120 24,00 x 93,60 7.005,50
103
152
H07V
VH6-
F
H
07VV
H6-F
0,161
1,211,913,3
4,95
www.remaskablo.com [email protected]
2121620
6180
1,91
0,78
7,98
3,3
212
45
80
120
184
1,21
0,554
0,272
0,161
7,9813,3
0,129
0,386
0,206
13,3
4,95
0,1610,206
0,2060,2720,3860,5540,78
20
33
61
103
16
120152184
25
253345
184212315
PVC INSULATED, PVC SHEATED FLEXIBLE CONTROL CABLES
CODE StandardsH07VVH6-F CU/PVC/PVC VDE 0245CU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed as control cables in mechanical, control equipment 1. Flexible wires with fine stranded copperfor tooling machinery production lines. And flexible conductorsapplications for free movement where low mechanical 2. PVC insulation.stress exists. (dry, ambitient and wet places.) 3. PVC sheath
mm² mm kg/km2 x 0,50 5,9 48,002 x 0,75 6,5 69,80
2 x 1 6,9 78,112 x 1,5 7,8 99,582 x 2,5 9,5 144,992 x 4 10,7 192,922 x 6 13,1 297,40
2 x 10 16,3 471,002 x 16 18,7 653,842 x 25 22,1 919,422 x 35 24,5 1.183,95
3 x 0,50 6,2 56,003 x 0,75 6,9 80,26
3 x 1 7,3 90,953 x 1,5 8,5 121,553 x 2,5 10,2 178,443 x 4 11,5 240,633 x 6 13,9 357,49
3 x 10 17,3 576,493 x 16 19,9 811,133 x 25 23,6 1.144,373 x 35 26,3 1.494,76
4 x 0,50 6,8 67,00
80103
162025334561
YSLY www.remaskablo.com
Current Carrying Capacity
ohm / km A
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C In Air
at 30 °C
4,953,3
1,911,210,78
3926
19,513,37,98
0,5543926
19,5
39
13,37,984,953,3
1,911,210,78
0,554
36
1016202533456180
10336
10
3
YSLY
YSL
Y
YSL
Y
4 x 0,75 7,5 94,814 x 1 8,1 112,04
4 x 1,5 9,4 150,694 x 2,5 11,1 214,374 x 4 12,6 295,904 x 6 15,1 440,57
4 x 10 19,0 714,584 x 16 21,8 1.013,214 x 25 26,0 1.441,024 x 35 29,0 1.889,83
5 x 0,50 7,4 80,005 x 0,75 8,3 114,80
5 x 1 8,8 131,835 x 1,5 10,4 183,495 x 2,5 12,3 265,615 x 4 14,1 369,425 x 6 16,5 530,22
5 x 10 20,7 863,305 x 16 23,9 1.229,895 x 25 28,5 1.753,625 x 35 31,9 2.313,39
6 x 0,50 7,2 81,006 x 0,75 9,6 159,75
6 x 1 10,1 183,286 x 1,5 11,6 242,616 x 2,5 13,6 347,316 x 4 15,2 438,006 x 6 17,3 638,00
6 x 10 17,3 682,006 x 16 24,6 1.467,006 x 25 29,4 2.118,006 x 35 32,9 2.778,00
7 x 0,50 8,5 98,007 x 0,75 9,6 158,70
7 x 1 10,1 182,977 x 1,5 11,6 242,517 x 2,5 13,6 348,947 x 4 15,2 468,007 x 6 18,2 786,00
7 x 10 22,2 1.195,007 x 16 27,3 1.782,007 x 25 29,4 2.471,007 x 35 32,9 3.240,00
8 x 0,50 8,4 110,008 x 0,75 10,7 189,68
8 x 1 11,3 219,198 x 1,5 13,0 292,718 x 2,5 15,3 423,388 x 4 17,3 576,008 x 6 19,3 860,00
8 x 10 23,9 1.388,008 x 16 27,3 1.969,008 x 25 33,3 2.823,008 x 35 36,4 3.703,00
9 x 0,50 9,9 145,009 x 0,75 11,5 223,34
2533
16
26
1,210,78
0,55439
19,513,37,984,953,3
3,31,91
20
80103
2619,513,37,984,953,3
1,91
4561
1,210,78
0,5543926
1,91
1,210,78
0,554
2619,513,37,984,95
4,953,3
1,911,210,78
3926
19,513,37,98
0,5543926
1016202533456180
10336
101620
19,5 10
39 36
10336
1016
2533456180
80103
36
10
2025334561
6180
10336
1625253345
6
1,210,78
0,554
YSLY
YSL
Y
YSL
Y13,37,984,953,3
1,91
9 x 1,5 14,1 347,749 x 2,5 16,7 505,499 x 4 19,4 671,009 x 6 21,3 968,00
9 x 10 26,4 1.561,009 x 16 30,6 2.215,009 x 25 36,7 3.176,009 x 35 41,1 4.166,00
10 x 0,50 9,5 137,0010 x 0,75 12,0 235,67
10 x 1 12,7 273,5610 x 1,5 14,7 368,6210 x 2,5 17,4 537,4010 x 4 19,9 745,0010 x 6 28,2 1.075,00
10 x 10 27,6 1.735,0010 x 16 32,0 2.461,0010 x 25 38,4 3.529,0010 x 35 43,0 4.629,00
12 x 0,50 10,6 173,0012 x 0,75 12,4 257,21
12 x 1 13,2 300,0912 x 1,5 15,2 406,3012 x 2,5 18,0 596,28
14 x 0,50 12,5 191,0014 x 0,75 13,0 285,98
14 x 1 13,8 334,9214 x 1,5 16,0 455,4514 x 2,5 19,0 671,89
16 x 0,50 11,4 218,0016 x 0,75 13,7 322,00
16 x 1 14,6 378,0916 x 1,5 16,9 516,2816 x 2,5 20,1 764,72
18 x 0,50 12,6 246,0018 x 0,75 14,5 359,80
18 x 1 15,4 423,2618 x 1,5 17,8 579,8718 x 2,5 21,2 861,53
19 x 0,50 12,9 251,0019 x 0,75 14,5 358,80
19 x 1 15,4 423,0319 x 1,5 17,8 579,9019 x 2,5 21,2 863,36
www.remaskablo.com [email protected]
7,984,953,3
1,911,21
13,3
13,37,984,953,3
1,91
0,780,554
3926
19,5
7,983926
19,513,37,983926
1,210,78
0,5543926
456180
1033
16252533
101625
33456180
103
610162525
36
101625
36
101625
36
101625
36
101625
36
YSLY
YSL
Y
YSL
Y
19,513,37,98
19,513,37,983926
19,513,37,983926
19,513,3
PVC INSULATED, SINGLE CORE CABLES
CODE StandardsHO5V-U, HO7V-U, HO7V-R CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004CU: IEC 60228 CLASS 1 & 2R: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V- 450/750 V
Application ConstructionUsed in covered, dry places, in fixed plants, 1. Solid or stranded copper conductor.in distribution panels, on and under plaster 2. PVC insulation.as laid in conduit.
mm² mm A10,00 5,9 7316,00 6,9 9825,00 8,3 12935,00 9,7 15850,00 11,3 19870,00 12,8 24595,00 14,6 292
120,00 16,2 344
H07V-R www.remaskablo.com
www.remaskablo.com [email protected]
938,00 0,1930 1971.172,00 0,1530 235
481,05 0,3870 132H07V
-R
108,42 1,8300 45
256,84
165
83167,71 1,1500 61
694,00 0,2680
0,7270356,09 0,5240 103
Type
Nominalcross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC Resistance at Conductor 20 °C
Current Carrying Capacity In ground
at 20 °C In Air
at 30 °Ckg/km ohm / km A
PVC INSULATED, SINGLE CORE CABLES
CODE StandardsHO5V-U, HO7V-U, HO7V-R CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004CU: IEC 60228 CLASS 1 & 2U: Solid Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V- 450/750 V
Application ConstructionUsed in covered, dry places, in fixed plants, 1. Solid or stranded copper conductor.in distribution panels, on and under plaster 2. PVC insulation.as laid in conduit.
mm² mm A1,50 2,8 242,50 3,3 324,00 3,8 426,00 4,3 54
10,00 5,5 73
www.remaskablo.com [email protected]
18,9131,5044,3463,27
104,473,081,83
H07V
-U 7,4112,1
45
4,6133252015
H07V-U www.remaskablo.com
Type
Nominalcross-section
OverallDiameter(approx.)
DC Resistance at Conductor 20 °C
NetWeight
(approx.)kg/km
Current Carrying Capacity In ground
at 20 °C In Air
at 30 °Cohm / km A
PVC INSULATED, SINGLE CORE CABLES
CODE StandardsHO5V-U, HO7V-U, HO7V-R CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004CU: IEC 60228 CLASS 1 & 2U: Solid Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V- 450/750 V
Application ConstructionUsed in covered, dry places, in fixed plants, 1. Solid or stranded copper conductor.in distribution panels, on and under plaster 2. PVC insulation.as laid in conduit.
mm² mm A0,50 2,0 90,75 2,2 151,00 2,3 19
H05V-U www.remaskablo.com
www.remaskablo.com [email protected]
13,54 18,1 11
A
H05V
-U 8,11 36,0 -10,73 24,5 -
Type Nominal
cross-section
OverallDiameter(approx.)
kg/km ohm / km
NetWeight
(approx.)
DC Resistanceat Conductor 20 °C
Current Carrying Capacity In ground
at 20 °C In Air
at 30 °C
PVC INSULATED, SINGLE CORE FLEXIBLE CABLES
CODE StandardsHO5V-K, HO7V-K CU/PVC TS EN 50525-2-31, VDE 0281, IEC 60227, BS 6004CU: IEC 60228 CLASS 5K: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V
Application ConstructionUsed in control panels and electrical 1. Flexible wires with fine stranded copperequipments of mobile devices, on and under conductors.plaster as laid in conduit. 2. PVC insulation.
mm² kg/km A A0,50 8,87 - 120,75 11,15 - 151,00 13,96 11 18
www.remaskablo.com [email protected]
ohm / km
H05V
-K 2,2 392,3 262,5 19,5
H05V-K www.remaskablo.com
Type Nominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC Resistanceat Conductor 20 °C
Current Carrying CapacityIn groundat 20 °C
In Airat 30 °C
mm
FLAT AND FLEXIBLE CABLES
CODE StandardsH03VVH2-F CU/PVC/PVC TS EN 50525-2-11, VDE 0281-5, IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/300V
Application ConstructionUsed on houshold appliances in covered, 1. Flexible wires with fine stranded copperdry, steamed and humid areas where low conductorsmechanical stress exists. 2 . PVC insulation.
3. PVC sheath
mm²2 x 0,502 x 0,75
2 x 13 x 0,503 x 0,75
3 x 14 x 0,504 x 0,75
4 x 15 x 0,505 x 0,75
5 x 1
H03VVH2-F www.remaskablo.com
www.remaskablo.com [email protected]
3,69 x 9,95 68,85 39 34,04 x 8,92 74,50 19,5 103,87 x 8,42 64,35 26 63,69 x 7,86
Current Carrying CapacityIn Air
at 30 °C
53,88 39 352,94 19,5 10
ohm / km A33962646,04
Type
mm kg/km38,913,69 x 5,77
3,87 x 6,15
Nominalcross-section
NetWeight
(approx.)
H03V
VH2-
F
DC ConductorResistance at 20 °C
OverallDiameter(approx.)
4,04 x 6,48
26
39
19,5
19,5
26
3,87 x 10,69
3,69 x 12,04
4,04 x 13,79
82,66
83,82
117,62
96,06
100,96
4,04 x 11,36
3,87 x 12,96
6
3
10
10
6
FLAT AND FLEXIBLE CABLES
CODE StandardsH05VVH2-F CU/PVC/PVC TS EN 50525-2-11, VDE 0281-5, IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500V
Application ConstructionUsed on houshold appliances in covered, 1. Flexible wires with fine stranded copperdry, steamed and humid areas where low conductorsmechanical stress exists. 2 . PVC insulation
3. PVC sheath
mm²2 x 0,75
2 x 12 x 1,52 x 2,52 x 4
3 x 0,753 x 1
3 x 1,53 x 2,53 x 4
4 x 0,754 x 1
4 x 1,54 x 2,54 x 4
5 x 0,755 x 1
5 x 1,55 x 2,55 x 4
H05VVH2-F www.remaskablo.com
www.remaskablo.com [email protected]
In Airat 30 °C
Current Carrying Capacity
Type
mm ohm / kmkg/km
Nominalcross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
10
A64,27 x 6,41
4,47 x 6,7843,65 26
19,549,12
H05V
VH2-
F
7,45 x 11,05
4,15 x 8,98
6,28 x 12,08
8,05 x 16,02
4,38 x 11,73
7,47 x 18,1
4,33 x 13,36
6,36 x 17,91
8,03 x 24,18
6,05 x 9,10
7,95 x 12,15
4,35 x 9,21
7,65 x 14,68
4,25 x 11,10
6,35 x 15,01
8,07 x 20,22
4,44 x 14,17
7,48 x 21,62
85,77
31,06
74,84
124,23
41,31
132,53
45,48
106,79
179,16
58,86
96,76
33,44
109,15
38,27
90,81
151,69
49,18
155,91
13,3
4,95
19,5
7,98
26
19,5
7,98
7,98
26
13,3
4,95
19,5
7,98
26
13,3
32
10
2513,3
4,956
16
324,95
16
32
10
25
6
16
32
10
25
25
6
16
FLAT AND NOT-SHEATED FLEXIBLE CABLES
CODE StandardsH03VH-H CU/PVC TS EN 50525-2-11, VDE 0281-5, IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/300V
Application ConstructionUsed in dry and humid places as a connecting 1.Flexible wires with fine stranded coppercable where low mechanical stress exists. conductors
2.PVC sheath
mm² kg/km2 x 0,50 21,262 x 0,75 26,853 x 0,50 31,893 x 0,75 40,28
www.remaskablo.com [email protected]
Current Carrying CapacityIn Air
at 30 °C
Nominalcross-section
H03V
H-H 3
639
2,73 x 5,31 262,26 x 4,99
2,71 x 8,082,52 x 7,48
2639
63
H03VH-H www.remaskablo.com
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
A
Type
mm ohm / km
FLAT AND NOT-SHEATED FLEXIBLE CABLES
CODE StandardsH03VH-H CU/PVC TS EN 50525-2-11, VDE 0281-5, IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/300V
Application ConstructionUsed in dry and humid places as a connecting 1.Flexible wires with fine stranded coppercable where low mechanical stress exists. conductors
2.PVC sheath
mm² kg/km2 x 1 32,35
2 x 1,5 45,292 x 2,5 69,082 x 4 98,982 x 6 135,603 x 1 48,52
3 x 1,5 67,943 x 2,5 103,623 x 4 148,483 x 6 203,41
4,13 x 7,99
4,12 x 11,98
www.remaskablo.com [email protected]
A
H05V
H-H
3,08 x 5,893,42 x 6,78
4,61 x 13,455,12 x 15,03
19,513,37,984,953,3
19,513,3
H05VH-H www.remaskablo.com
Type Nominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
Current Carrying CapacityIn Air
at 30 °Cmm ohm / km
7,984,953,3
4,61 x 9,15,15 x 10,093,02 x 8,69
3,45 x 10,08
10162532451016253245
FLAT AND NOT-SHEATED CABLE WITH COPPER CONDUCTOR
CODE StandardsH03VH-H CU/PVC VDE 0281, BS 6004CU: IEC 60228 CLASS 1 & 2U: Solid Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/300V
Application ConstructionUsed in dry and humid places as a connecting 1. Solid or stranded copper conductor.cable where low mechanical stress exists. 2. PVC sheat.
mm² kg/km2 x 1 43,00
2 x 1,5 56,002 x 2,5 84,002 x 4 115,002 x 6 165,003 x 1 56,00
3 x 1,5 78,003 x 2,5 119,003 x 4 161,003 x 6 226,00
A
CORD
ON
MO
NO
www.remaskablo.com [email protected]
CORDON MONO www.remaskablo.com
Type Nominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
Current Carrying CapacityIn Air
at 30 °Cmm ohm / km
5,12 x 15,86
3,82 x 11,954,39 x 13,82
2,75 x 8,853,22 x 9,68
4,35 x 9,125,12 x 10,48
3,19 x 6,823,81 x 7,92
2,70 x 5,72 18,112,17,414,61
3,08
12182634441218263444
3,0818,112,17,414,61
PVC INSULATED, PVC OUTER SHEATHED INSTALLATION CABLE WITH COPPER CONDUCTOR
CODE StandardsNVV-NYM-05VV-U CU/PVC/PVC IEC 227-10 TS 9759 HD 21.4.S2-VDE 0250-204CU:IEC 60228 CLASS 1 & 2U: Solid ConductorR: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 450/750 V
Application ConstructionUsed in humid places, in conduits 1. Solid or stranded copper conductor.on and under plaster where low 2. PVC insulation.mechanical stress exists. 3. PVC filler
4. PVC sheath
mm² kg/km2 x 1 95
2 x 1,5 119,952 x 2,5 155,172 x 4 199,122 x 6 260,56
2 x 10 444,412 x 16 627,012 x 25 940,002 x 35 1.163,813 x 1 112,00
3 x 1,5 135,523 x 2,5 181,363 x 4 244,273 x 6 347,47
3 x 10 554,703 x 16 876,003 x 25 1.273,003 x 35 1.524,154 x 1 129,00
4 x 1,5 163,504 x 2,5 224,794 x 4 313,22
9,9
9,1
23,7
11,810,7
8,6
15,5
18,1
18,1
7,4112,1
21,818,1
NVV-NYM www.remaskablo.com
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC ConductorResistance at 20 °C
Current Carrying CapacityIn Air
at 30 °CAohm / kmmm
NYM
NYM
8,0
24,924,519,4
12,77,414,61
12,1
4,613,08
108
342611,3
9,99,1 18,1
11,3
0,7270,524
1,831,15
16,713,0
82
10,4
8,3
12
12
12
18
2618
61
18
135
44
7,41
0,5240,7271,151,833,084,61
12,1
3426
13510882614434
4 x 6 436,104 x 10 684,764 x 16 1.074,004 x 25 1.581,004 x 35 1.891,005 x 1 151,00
5 x 1,5 205,005 x 2,5 289,005 x 4 400,505 x 6 525,00
5 x 10 840,005 x 16 1.205,005 x 25 1.800,005 x 35 2.345,00
3,081,831,15
0,7270,524
25,821,418,614,9
28,210882
NYM
NYM
www.remaskablo.com [email protected]
0,727
1,83
4,61
12,1
1,15
3,08
7,41
18,1135
30,0
23,0
15,3
12,3
9,6
0,524
10,7
14,0
19,9
27,2135
12
26
44
108
61
34
18
82
6144
PVC INSULATED, PVC OUTER SHEATHED FLAT CABLE WITH COPPER CONDUCTOR
CODE StandardsFLAT TWIN CU/PVC/PVC BS 6004CU: IEC 60228 CLASS 1 & 2U: Solid ConductorR: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V
Application ConstructionUsed for fixed wiring in humid places, 1. Solid or stranded copper conductor.in conduits on and under plaster where 2. PVC insulation.low mechanical stress exists. 3. PVC sheath
mm² mm2 x 1 4,25 x 6,55
2 x 1,5 4,76 x 7,442 x 2,5 5,65 x 9,042 x 4 5,84 x 9,612 x 6 6,6 x 11,1
2 x 10 8,8 x 14,92 x 16 10,1 x 17,32 x 25 11,35 x 19,752 x 35 12,75 x 22,153 x 1 4,25 x 8,85
3 x 1,5 4,81 x 10,623 x 2,5 5,47 x 12,293 x 4 6,67 x 16,093 x 6 7,35 x 18,53
3 x 10 8,8 x 21,13 x 16 10,1 x 24,53 x 25 11,35 x 28,153 x 35 12,75 x 31,554 x 1 4,25 x 11,15
4 x 1,5 4,70 x 12,954 x 2,5 5,45 x 15,454 x 4 6,15 x 17,454 x 6 6,60 x 19,45
77,00
685,001,15
3,08
kg/km
68,0018,1
686,00 1,15
142,31
185,00
231,89
101,59
95,04132,00
53,84
8261474,00
FLAT TWIN www.remaskablo.com
Nominalcross-section
OverallDiameter(approx.)
NetWeight
(approx.)
7,4112,1
319,00 1,83 614434
296,00
ohm / km
3,08
7,41
461,00
910,00
Type
1,83
4,61
2618
DC ConductorResistance at 20 °C
Current Carrying CapacityIn Air
at 30 °CA
12,1
44342618
82
135
4,61
270,00
135,00
1.330,00999,00
97,00
195,00
365,00
0,524
0,727
18,1
7,41
3,08
18,1
1080,524
12,1
4,61
12
108
FLAT
TW
IN
FLAT
TW
IN
135
18
34
12
26
44
0,727
12
4 x 10 8,45 x 26,354 x 16 9,70 x 30,554 x 25 11,35 x 36,554 x 35 12,75 x 40,955 x 1 4,25 x 13,45
5 x 1,5 4,70 x 15,705 x 2,5 5,45 x 18,755 x 4 6,15 x 21,255 x 6 6,65 x 23,70
5 x 10 8,45 x 32,205 x 16 9,70 x 37,705 x 25 11,35 x 44,955 x 35 12,75 x 50,35
www.remaskablo.com [email protected]
1.749,00
161,00
335,00
749,00
1.635,002.175,00
1.095,00
445,00
245,00
121,00
1.315,00
605,00880,00
0,524
1,15
0,524
12,1
4,61
1,83
0,727
1,83
0,727
18,1
7,41
3,08
1,15
135
FLAT
TW
IN
FLAT
TW
IN
18
34
61
108
61
108
12
26
44
82
82
135
PVC INSULATED, PVC OUTER SHEATHED FLAT CABLE WITH COPPER CONDUCTOR
CODE StandardsTWIN&EARTH CU/PVC/PVC BS 6004CU: IEC 60228 CLASS 1 & 2U: Solid ConductorR: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/500 V
Application ConstructionUsed for fixed wiring in humid places for 1.Earthpermanent installation on and under 2.Solid or stranded copper conductorplaster where low mechanical stress exists. 3.PVC insulation
4.PVC sheath
mm kg/km4,25 x 5,35 54,004,75 x 5,80 66,004,40 x 7,90 75,004,78 x 8,50 84,785,45 x 9,95 125,005,57 x 9,87 117,90
6,30 x 11,80 182,007,14 x 14,20 242,358,48 x 16,65 375,008,78 x 17,87 389,599,75 x 19,35 545,00
10,00 x 20,30 589,574,35 x 9,95 95,00
4,75 x 11,35 120,005,45 x 13,25 168,005,45 x 13,45 175,006,15 x 15,10 235,006,59 x 16,99 315,008,49 x 22,48 525,009,72 x 26,25 749,00
Current Carrying CapacityIn Air
at 30 °Cohm / km A
3 x 2,5+1
Nominal cross-section
Overall Diameter (approx.)
1 x 1+11 x 1,5+1
7,41/12,10
12,10/18,1018,1/18,10
NetWeight
(approx.)
DC Conductor Resistance at 20 °C
1,15/1,83 82
3 x 16+6
3 x 1+13 x 1,5+1
www.remaskablo.com [email protected]
18,1/18,10
7,41/18,1
4,61/12,10
1,83/4,61
3 x 2,5+1,53 x 4+1,53 x 6+2,5 3 x 10+4
82
44
26
TWIN & EARTH www.remaskablo.com
Type
mm²
2 x 10+6
2 x 6+2,5 2 x 4+1,5
2 x 2,5+1,5
2 x 1,5+12 x 1+1
TWIN
& E
ARTH
1,15/3,08
3,08/7,41
7,41/12,10
12,10/18,10
12,10/18,1018,1/18,10
2 x 16+10
1,83/4,61
1,15/3,08
2 x 2,5+1
2 x 10+4
2 x 16+61,83/3,08
3,08/7,414,61/12,10
7,41/18,1
18
18
26
34
61
1218
61
443426
12
61
26
82
12
PVC INSULATED, PVC OUTER SHEATHED FLAT CABLE WITH COPPER CONDUCTOR
CODE StandardsNYIFY CU/PVC/PVC DIN VDE 0250-201CU: IEC 60228 CLASS 1 & 2U: Solid ConductorR: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 230/400 V
Application ConstructionUsed for fixed wiring in dry and humid places 1. Solid or stranded copper conductorfor permanent installation on and under plaster 2. PVC insulation.where low mechanical stress exists. It is suitable 3. PVC sheathto nail with its pvc bridge between cores.
mm² mm2 x 1,5 3,68 x 12,662 x 2,5 4,17 x 13,302 x 4 5,13 x 14,032 x 6 6,10 x 16,19
3 x 1,5 3,75 x 18,373 x 2,5 4,7 x 19,63 x 4 5,3 x 21,43 x 6 6,25 x 26,19
4 x 1,5 3,9 x 25,5
NYIF
Y-U
192,00
87,9462,00
NYIFY-U www.remaskablo.com
18
342618
3426
4,617,4112,1
4,61
135,00
www.remaskablo.com [email protected]
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC Conductor Resistance at 20 °C
Current Carrying CapacityIn Air
at 30 °Cohm / km Akg/km
12,1 18131,00
7,4112,1
93,00
125,00
44
443,08
3,08
179,00
271,00
PVC INSULATED, PVC OUTER SHEATHED FLAT AND FLEXIBLE CABLE
CODE StandardsNYIFY CU/PVC/PVC DIN VDE 0250-201CU: IEC 60228 CLASS 5F: Flex copper conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 230/400 V
Application ConstructionUsed for fixed wiring in dry and humid places 1. Flexible wires with fine stranded copperfor permanent installation on and under plaster conductorswhere low mechanical stress exists. It is suitable 2. PVC insulation.to nail with its pvc bridge between cores. 3. PVC sheath
mm² mm2 x 1 3,75 x 10,25
2 x 1,5 4,10 x 10,952 x 2,5 4,99 x 12,422 x 4 5,60 x 14,652 x 6 6,42 x 16,753 x 1 3,80 x 16,65
3 x 1,5 4,10 x 17,953 x 2,5 4,85 x 20,103 x 4 5,60 x 23,893 x 6 6,45 x 27,10
www.remaskablo.com [email protected]
Current Carrying CapacityIn Air
at 30 °Ckg/km ohm / km A
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
DC Conductor Resistance at 20 °C
62,00
3,3
3,3
19,5
25
NYIFY-F www.remaskablo.com
181,00
51,00
NYIF
Y-F
78,00
275,00197,00
92,00130,00
140,0095,00
10
45
45
10
4,95
1613,3
19,5
7,9832
7,98 254,95 32
13,3 16
PVC INSULATED, MULTI-CORE FLEXIBLE CABLES
CODE StandardsH03VV-F CU/PVC/PVC TS EN 50525-2-11, VDE 0281-5-IEC60227-5CU: IEC 60228 CLASS 5F: Flexible conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 300/300V
Application ConstructionUsed on houshold appliances in covered, 1. Flexible wires with fine stranded copperdry, steamed and humid places where conductorslow mechanical stress exists. 2. PVC insulation.
3. PVC sheath Current Carrying Capacity
mm² mm kg/km ohm / km A2 x 0,50 5,1 37,34 39 32 x 0,75 5,4 43,87 26 63 x 0,50 5,4 40,62 39 33 x 0,75 6,0 54,46 26 64 x 0,50 6,0 51,57 39 34 x 0,75 6,4 65,93 26 6
www.remaskablo.com [email protected]
H03VV-F www.remaskablo.com
DC ConductorResistance at 20 °C
H03V
V-F
Type Nominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.) In Air
at 30 °C
PVC INSULATED, PVC OUTER SHEATHED CABLE WITH COPPER CONDUCTOR
CODE StandardsYVV-NYY CU/PVC/PVC IEC 60502-1, VDE 0271-0276CU: IEC 60228 CLASS 1 & 2U: Solid ConductorR: Stranded Conductor
Technical DataMax. operating temperature : 70 °CShort circuit temperature : 160 °C (max. 5 sn.)Rated voltage : 0,6/1Kv
Application ConstructionUsed ase power cables where low mechanical 1. Solid or stranded copper conductor.stress exists indoors,under ground,in cable 2. PVC insulation.ducts and industrial plants. 3. PVC filler
4. PVC sheath
mm² mm kg/km ohm / km O O O O º O O O O O º O1 x 1,5 5,9 52,00 12,1 25 201 x 2,5 6,3 61,00 7,41 34 271 x 4 7,2 93,00 4,61 - - 45 371 x 6 7,7 115,00 3,08 - - 57 48
1 x 10 8,8 154,00 1,83 - - 78 661 x 16 9,8 223,00 1,15 127 107 103 891 x 25 11,5 330,00 0,727 163 137 137 1181 x 35 12,5 420,00 0,524 195 165 169 1451 x 50 15,2 576,30 0,387 230 195 206 1761 x 70 15,5 772,00 0,268 282 239 261 2241 x 95 18,2 1.035,00 0,193 336 287 321 271
1 x 120 19,6 1.270,00 0,153 382 326 374 3142 x 1,5 10,1 147,09 12,12 x 2,5 10,7 182,63 7,412 x 4 12,8 261,00 4,612 x 6 13,8 316,56 3,08
2 x 10 16,4 470,45 1,832 x 16 18,1 649,4 1,152 x 25 21,0 939,00 0,7272 x 35 23,0 1.180,00 0,5242 x 50 26,2 1.560,00 0,3872 x 70 30,0 2.345,00 0,2682 x 95 33,7 2840 0,193
2 x 120 37,0 3.490,00 0,153
TypeNominal
cross-section
OverallDiameter(approx.)
NetWeight
(approx.)
150116
DC ConductorResistance at 20 °C
Current Carrying Capacity
90 66
3768
NYY
N
YY
215 176
In groundat 20 °C
In Airat 30 °C
32 2042 2754
118181 145
89
48
264 224318 271360 314
YVV ( NYY) www.remaskablo.com
3 x 1,5 10,5 174,00 12,13 x 2,5 11,4 172,00 7,413 x 4 13,4 300,60 4,613 x 6 14,9 380,14 3,08
3 x 10 18,8 651,56 1,833 x 16 19,8 812,00 1,153 x 25 22,4 1.143,75 0,7273 x 35 25,0 1.510,00 0,5244 x 1,5 11,5 204,79 12,14 x 2,5 12,8 284,21 7,414 x 4 14,3 354,76 4,614 x 6 16,0 471,39 3,08
4 x 10 19,8 692,29 1,834 x 16 22,2 1.010,00 1,154 x 25 26,2 1.030,44 0,7274 x 35 28,8 1.918,23 0,524
3 x 16+10 21,8 972,33 1,15/1,833 x 25+16 26,1 1.446,37 0,727/1,153 x 35+16 27,8 1.773,15 0,524/1,15
5 x 1,5 12,4 271,00 12,17 x 1,5 12,8 270,55 12,1
10 x 1,5 16,2 412,40 12,112 x 1,5 17,6 483,00 12,114 x 1,5 17,7 546,00 12,119 x 1,5 20,3 685,00 12,15 x 2,5 13,7 365,00 7,417 x 2,5 15,1 398,00 7,41
10 x 2,5 18,6 600,00 7,4112 x 2,5 19,1 656,00 7,4114 x 2,5 19,4 730,00 7,4119 x 2,5 22,0 924,00 7,41
NYY
NYY
44 34
26 18,534 25
157 13126 18,5
56 4375 6098 80
128 106
34 2544 3456 4375 6098 80
128 106157 13198 80
128 106157 13124 1816 1213 1012 1012 9
www.remaskablo.com [email protected]