Upload
anil-kumar-kn
View
217
Download
0
Embed Size (px)
Citation preview
7/31/2019 Dust Fighter
1/4
D U S T
C O N T R O L
S Y S T E M
Quarries and Mines | Inert Recycling Systems
Building and Demolition sites | Cement
Solid Urban Waste landfll | Tunnelling
Steel factories | Woodworking plants | Ports
7/31/2019 Dust Fighter
2/4
Technical
SpecifcationsDF 5000 DF 7500 DF 15000 DF 20000
Electrical engine power (fan) 5.5 kW 7.5 kW 15 kW 22 kW
Electrical connection Inlet Three-phase 16 A Inlet Three-phase 32 A Inlet Three-phase 32 A Inlet Three-phase 63 A
Water connection UNI 45 UNI 45 UNI 45 UNI 45
Average water pressure 6 bar 6 bar 6 bar 6 bar
Nominal pressure Min 2 bar - Max 11 bar Min 2 bar - Max 11 bar Min 2 bar - Max 11 bar Min 2 bar - Max 11 bar
Coverage 20 - 30 m*
*without wind
30 - 40 m*
*without wind
40 - 50 m*
*without wind
50 - 60 m*
*without wind
Water Consumption 18.3 l/min @10 bar 34 l/min @10 bar 42 l/min @10 bar 54 l/min @10 bar
Type of water Potable/Non potable Potable/Non potable Potable/Non potable Potable/Non potable
Water flter Yes Yes Yes Yes
Manual oscillation 360 360 360 360
Dimensions ( L X W X H mm) 2.800X1.490X1.700 3.300X1.830X2.180 3.300x1.830x2.180 3.300x1.830x2.180
Weight 450 kg 690 kg 790 kg 830 kg
Suppresses Dust
Manual and Automatic operation
Reduced water consumption
Avoids sludge formation
Covers large work area
DUST CONTROL SYSTEM
Coverage (Without wind)
7/31/2019 Dust Fighter
3/4
FEATURES
DF 5000 DF 7500
STANDARD
EQUIPMENT
- Three-phase 16 A inlet
- Complete with a two wheels undercarriage and
tow bar, with fork lift pockets
- 2 x Height adjustable stabilizers
- Control panel
- Integrated booster pumps to control the correct
working pressure
- Pressure gauge
- Flowmeter
- Phase inverter
- Three-phase 32 A inlet
- Complete with a two wheels undercarriage and
tow bar, with fork lift pockets
- 2 x Height adjustable stabilizers
- Control panel- Integrated booster pumps to control the correct
working pressure
- Flowmeter
- Phase inverter
OPTIONAL - Automatic oscillation system managed from the
control panel; the range of work can cover from
0 to 335
- Pump for chemical additives
- Remote control to switch the Dust-Fighter On &Off, Pump On & Off, electrical rotation (if present)
- Tilting system
- Automatic oscillation system managed from the
control panel; the range of work can cover from
0 to 335
- Pump for chemical additives
- Remote control to switch the Dust-Fighter On &Off, Pump On & Off, electrical rotation (if present)
- Tilting system
NOTES Usage of 15 kW - 380 V generator, or larger is
recommended for powering the Dust-Fighter from a
generating set.
Usage of 30 kW - 380 V generator, or larger is
recommended for powering the Dust-Fighter from a
generating set.
DF 15000 DF 20000
STANDARD
EQUIPMENT
- Three-phase 32 A inlet
- Complete with a two wheels undercarriageand tow bar, with fork lift pockets
- 2 x Height adjustable stabilizers
- Control panel
- Integrated booster pumps to control the
correct working pressure
- Pressure gauge
- Flowmeter
- Phase inverter
- Three-phase 63 A inlet
- Complete with a two wheels undercarriage andtow bar, with fork lift pockets
- 2 x Height adjustable stabilizers
- Control panel
- Integrated booster pumps to control the correct
working pressure
- Pressure gauge
- Flowmeter
- Phase inverter
OPTIONAL - Automatic oscillation system managed from the
control panel;the range of work can cover from 0
to 335
- Pump for chemical additives
- Remote control to switch the Dust-Fighter On &
Off, Pump On & Off, electrical rotation (if present)
- Tilting system
- Automatic oscillation system managed from the
control panel; the range of work can cover from 0
to 335
- Pump for chemical additives
- Remote control to switch the Dust-Fighter On &
Off, Pump On & Off, electrical rotation (if present)
- Tilting system
NOTES Usage of 50 kW - 380 V generator, or larger is
recommended for powering the Dust-Fighter from a
generating set.
Usage of 60/65 kW - 380 V generator, or larger is
recommended for powering the Dust-Fighter from a
generating set.
7/31/2019 Dust Fighter
4/4