48
DrillSaw Highspeed 200 Power System AR-200

DrillSaw Highspeed 200™ Power System AR-200

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DrillSaw Highspeed 200™ Power System AR-200

DrillSaw Highspeed 200™ Power System

AR-200

Page 2: DrillSaw Highspeed 200™ Power System AR-200

DrillSaw Highspeed 200™ Power System

The versatile Arthrex DrillSaw Highspeed

200 power system is designed for multiple

distal extremity procedures.

The unique corded power system functions

at high torque and low speed, which makes

it optimal for repetitive bony cuts while

sparing the surrounding soft tissue. As

such, this system is perfect for minimally

invasive foot surgery.

The system is also compatible with all AR-

300 attachments, making it a capable,

corded power unit.

2

Page 3: DrillSaw Highspeed 200™ Power System AR-200

DrillSaw Highspeed 200™ Power System

Number One in Operation

3

The following can be set individually:

Program [ ]

Motor speed [rpm]

Torque [Ncm]

Coolant supply volume [ ]

Transmission ratio [ ]

Page 4: DrillSaw Highspeed 200™ Power System AR-200

DrillSaw Highspeed 200™ Power System

Number One in Operation

4

Automatic

detection of motor

Ideal for minimally

invasive surgery

AR-200M can

be used with all

DrillSaw Mini

300™ attachments

Motor with cable

and motor holder

are sterilizable

(135 °C)

Page 5: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Number One in the Operating Room

5

Powerful Motor

Top quality and power – for all surgical applications

AR-200M

Motor speed of 300 - 15 000 rpm

AR-200M-ISO

Motor speed of 300 - 40 000 rpm

Shortest and lightest 40 000 rpm motor on the market

Length: 82.5 mm

Weight: 137 g

Motor with cable and motor holder are sterilizable

(135 °C)

Page 6: DrillSaw Highspeed 200™ Power System AR-200

AR-200M

6

Motor speed of 300 - 15 000 rpm

Coupling for AR-300 attachments

Page 7: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Display

AR-200M

15.000

Logical Integration for Ease of Use:

One operating stage for setting the most crucial

parameters

Six programs can be set individually

7

Page 8: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Foot Pedal

8

Intelligent Foot Control:

Program selection

Connection and disconnection of coolant pump

Forward/reverse operation

Infinitely variable control of the motor up to the

preselected speed

On/off function

IPX8- and AP-tested

Page 9: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Overview - Front

9

Page 10: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Overview - Back

10

Fuse holder with two fuses

REF 06352200 (250V - T1.6AH)

Page 11: DrillSaw Highspeed 200™ Power System AR-200

Operated by four buttons on the device:

> Two buttons for selecting parameters

> Two buttons for changing parameters

AR-200 Operational Design

11

Page 12: DrillSaw Highspeed 200™ Power System AR-200

Change program:

AR-200 Operational Design

12

AR-200M

15.000

Page 13: DrillSaw Highspeed 200™ Power System AR-200

Change selection:

AR-200 Operational Design

13

AR-200M

15.000

Page 14: DrillSaw Highspeed 200™ Power System AR-200

Change speed:

AR-200 Operational Design

14

AR-200M

15.000

Page 15: DrillSaw Highspeed 200™ Power System AR-200

Change selection:

AR-200 Operational Design

15

AR-200M

15.000

Page 16: DrillSaw Highspeed 200™ Power System AR-200

Torque setting:

AR-200 Operational Design

16

AR-200M

15.000

Page 17: DrillSaw Highspeed 200™ Power System AR-200

Change selection:

AR-200 Operational Design

17

AR-200M

15.000

Page 18: DrillSaw Highspeed 200™ Power System AR-200

Coolant supply volume:

AR-200 Operational Design

18

AR-200M

15.000

AR-200M

Page 19: DrillSaw Highspeed 200™ Power System AR-200

Change selection:

AR-200 Operational Design

19

AR-200M

15.000

Page 20: DrillSaw Highspeed 200™ Power System AR-200

Transmission ratio:

AR-200 Operational Design

20

AR-200M

15.000

Page 21: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

AR-200 Operational Design

21

AR-200M

15.000

Hold both for two seconds

Page 22: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

AR-200 Operational Design

22

Selection menu

Page 23: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Operational Design

23

Selection menu Setup settings:

Page 24: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

Confirm selection

AR-200 Operational Design

24

Page 25: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

AR-200 Operational Design

25

Selection menu

Page 26: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

Confirm selection

AR-200 Operational Design

26

Page 27: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

AR-200 Operational Design

27

Exit menu

Page 28: DrillSaw Highspeed 200™ Power System AR-200

Setup settings:

Change parameters

AR-200 Operational Design

28

Selection

Page 29: DrillSaw Highspeed 200™ Power System AR-200

How to Set Up the Console

29

Page 30: DrillSaw Highspeed 200™ Power System AR-200

Basic Setup Procedure for AR-200

Connect the power cord

Connect the foot control

cable to the console

Connect the handpiece

motor to the console

Set up the AR-200

30

Page 31: DrillSaw Highspeed 200™ Power System AR-200

Irrigation Pump Tubing Setup

Basic Setup Procedure for AR-200

31

Press

a Open the pump arm door

b,c Insert the irrigation pump tubing

d Close the pump arm door

Page 32: DrillSaw Highspeed 200™ Power System AR-200

Basic Setup Procedure for AR-200

32

Follow the same sequence when

removing the irrigation tubing

Page 33: DrillSaw Highspeed 200™ Power System AR-200

Connecting Attachments to the AR-200M Motor

33

Turn the motor chuck mechanism.

To insert the attachment

Push the adapter into the locking mechanism

and release the chuck mechanism.

Page 34: DrillSaw Highspeed 200™ Power System AR-200

Connecting Attachments to the AR-200M Motor

34

Turn the motor chuck mechanism. Pull out the adapter.

To Remove the Attachment

Page 35: DrillSaw Highspeed 200™ Power System AR-200

AR-200SP Spray Clip

35

Attach the spray clip to the motor.

The spray clip groove matches with the

coupling ring of the motor.

Insert the tubing end onto the

proximal rod end of the spray clip.

Fix the irrigation tubing in

the clips of the motor cable.

Page 36: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Factory Settings

AR-200M

36

Program Speed

[rpm]

Torque

[Ncm ]

Coolant Supply

Volume

Coolant Transmission

Ratio

Motor

Direction

P1 15 000 100 % 100 % Disabled 1:1 Clockwise

P2 8 000 100 % 100 % Disabled 1:1 Clockwise

P3 3 000 100 % 100 % Disabled 1:1 Clockwise

P4 15 000 100 % 100 % Disabled 1:1 Clockwise

P5 15 000 100 % 100 % Disabled 1:1 Clockwise

P6 15 000 100 % 100 % Disabled 1:1 Clockwise

Page 37: DrillSaw Highspeed 200™ Power System AR-200

Technical Data

37

Console AR-200C

Power supply 110 - 130 V / 220 - 240 V, 50/60 Hz, 0.1 - 1.8 A / 0.1 - 0.9 A

Dimensions (W/H/D) 256 mm (10 in) x 109 mm (4.3 in) x 305 mm (12 in)

Weight 7.0 kg (15.4 lb)

Maximum flow rate ≥ 90 mL/min

Mains fuse 2 ˣ 250 V – T1.6AH

AR-200M

Torque 7 Ncm

Speed 300 – 15 000 rpm

Page 38: DrillSaw Highspeed 200™ Power System AR-200

AR-200 Error Message

38

Foot control not

recognized

Button pressed during

start-up

Foot control faulty

Electronics

temperature

Motor not recognized

Motor error

Motor faulty

Service

Electronics overloaded

Page 39: DrillSaw Highspeed 200™ Power System AR-200

Saw Attachments

39

Saw attachment –

reciprocating AR-300SR

Saw attachment – sagittal AR-300SAG

Page 40: DrillSaw Highspeed 200™ Power System AR-200

Drill Attachments

40

Drill keyless chuck

(0 - 3 mm) AR-300DK30

Drill attachment – style AO AR-300DAO-2

Drill keyless chuck

(2.0 - 4.5 mm) AR-300DK45

Drill Jacobs chuck

(0 - 4 mm) 1 300 rpm AR-300DJ

Drill Jacobs chuck hybrid

(0 - 5 mm) 1 300 rpm AR-300DJH

Page 41: DrillSaw Highspeed 200™ Power System AR-200

Burr Attachments

41

Drill attachment 2.35 mm AR-300B-2

2 750 rpm

Burr attachment 2.35 mm AR-300B

15 000 rpm

Page 42: DrillSaw Highspeed 200™ Power System AR-200

Reamer Attachments

42

Reamer Jacobs chuck

(0 - 4 mm) 500 rpm AR-300RJ

Reamer adapter AO

500 rpm AR-300RAO

Please use the ream attachments

for hindfoot and ankle procedures!

Higher torque !

Page 43: DrillSaw Highspeed 200™ Power System AR-200

Wire/Pin Driver Attachments

43

Pin driver attachment

(1.0 - 2.4 mm) AR-300PD24

Wire driver attachment

(0.6 - 1.6 mm) AR-300WD16

Page 44: DrillSaw Highspeed 200™ Power System AR-200

Adapters

44

Offset adapter AR-200CA

Spray clip AR-200SP

Page 45: DrillSaw Highspeed 200™ Power System AR-200

Coupling Geometries

45

Round shank

Twist drill AO (mini quick)

J-notch

Dental

AR-300B

AR-300B-2

Hex (-agonal) coupling (mainly US)

AO-ASIF quick coupling (Synthes)

All drill and screw

attachments are offered with

different coupling geometries

Page 46: DrillSaw Highspeed 200™ Power System AR-200

Color Coding

46

Ream attachment:

Marked red + AR-300R

500 rpm

Drill attachment:

Marked green + AR-300D

1 300 rpm

Page 47: DrillSaw Highspeed 200™ Power System AR-200

Arthrex Power Family

47

Prosthetics Trauma

Heavy Duty

Trauma

Light Duty

Foot Hand

DrillSaw Max 600™

power system

DrillSaw Mini 300™

power system

DrillSaw Sports 400™

power system

DrillSaw Highspeed

200™ power system

Optimal

Possible

Page 48: DrillSaw Highspeed 200™ Power System AR-200

This description of technique is provided as an educational tool and clinical aid to assist properly licensed medical professionals in the usage of specific

Arthrex products. As part of this professional usage, the medical professional must use their professional judgment in making any final determinations in

product usage and technique. In doing so, the medical professional should rely on their own training and experience and should conduct a thorough

review of pertinent medical literature and the product’s directions for use. Postoperative management is patient-specific and dependent on the treating

professional’s assessment. Individual results will vary and not all patients will experience the same postoperative activity level or outcomes.

© 2018. Arthrex, Inc. All right reserved. | www.arthrex.com | PPT1-000000-en-US_B